JA-5 Drawings - CHPP Phase A - Eielson AFB AK

View the file

Other files for this federal contract opportunity

Other files attached to CHPP Phase A, newest first.
File Type Posted
Phase_A_Bidder_Q&A.pdf PDF
FA500418BC0040001.pdf PDF
FA500418BC004.pdf PDF
JA-3_AF_Form_66.pdf PDF
JA-2_Specs.pdf PDF
JA-1_SOW.pdf PDF
JA-4_Wage_Determination.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

THIS PROJECT

EIELSON AIR FORCE BASE VICINITY MAP

PACIFIC AIR FORCES

354th CE Squadron

Eielson Air Force Base

FTQW 18-0504

REPAIR CENTRAL HEATING & POWER PLANT (CH & PP)

ELECTRICAL PANELS & CIRCUITS, PHASE A

SHEET INDEX

SHEET NUMBER SHEET TITLE

E0

TITLE SHEET, INDEX, AND VICINITY MAP

E1 LEGEND AND SCHEDULES

E2 LIGHTING NEW WORK ONE-LINE DIAGRAM

E3 BASEMENT LIGHTING PLAN

E4 FIRST FLOOR LIGHTING PLAN

E5 BASEMENT FLOOR LIGHTING DEMOLITION PLAN

E6 FIRST FLOOR LIGHTING DEMOLITION PLAN

E7 PANEL SCHEDULES

H1 ACM AND DUST SAMPLE LOCATIONS AND RESULTS

H2 LBP SAMPLE LOCATIONS AND RESULTS

F500

AREA CLASSIFICATION PLANS (ISSUED FOR REFERENCE)

ER1

EXISTING ELECTRICAL ONE-LINE DIAGRAM

(ISSUED FOR REFERENCE)

David Harr

EE-10223

01/26/2018

REG IST ER E D P R O F E S S IO NA L ENGINEER

David Harr

EE-10223

A-#

A-#

SD-#

LEGEND

FIRST FLOOR FOURTH FLOOR

ASH HOUSE

A-3

A-4

A-5

A-6

A-7

A-8

A-9

A-10

A-1

SD-6

SD-1

SD-2

SD-5

A-2

SD-3

SD-4

ASBESTOS SAMPLE LOCATIONS NEGATIVE (<1%

ASBESTOS)

ASBESTOS SAMPLE LOCATIONS POSITIVE (>1%

ASBESTOS)

SETTLED DUST SAMPLE LOCATIONS

NOTES:

1. All settled dust sample locations contain detectable concentrations of RCRA 8-metal and silica.

See discussion in the hazardous material investigation report.

2. EPA HUD lead in dust standards:

Floors: 40(ug/ft²)

Interior windowsills: 250(ug/ft²)

Window troughs: 400(ug/ft²)

5TH FLOOR

4TH FLOOR

3RD FLOOR

2ND FLOOR

1ST FLOOR

BASEMENT

SHOP PANEL

BASEMENT

PANEL LP-1A

BASEMENT

PANEL LP-1

BASEMENT

PANEL A

BASEMENT

PANEL CH

1ST FLR

PANEL C

1ST FLR

GATE

HOUSE

PANEL

1ST FLR

COAL

HANDLING

PANEL

1ST FLR

PANEL H

1ST FLR

PANEL G

1ST FLR

PANEL B1

PUMP RM

PANEL B

PUMP RM

PANEL K

TURBINE RM

MAIN LP

TURBINE RM

ATS

TURBINE RM

SWGR 2

TURBINE RM

SWGR 1

TURBINE RM

PANEL P-1A

ELEC. SHOP

PANEL P-1

ELEC. SHOP

PANEL D

2ND FLR

PANEL N

3RD FLR

PANEL LP-4

3RD FLR

PANEL E

4TH FLR

PANEL J

4TH FLR

PANEL F

5TH FLR

ROOF PANEL

5TH FLR

PANEL PH

POND HOUSE

PANEL N.

SILO TOWER

PANEL N.

SILO TOWER

PANEL S.

SILO TOWER

PANEL S.

SILO TOWER

ASH HOUSE BUILDING

POND HOUSE BUILDING

LEGEND

SEE LEAD BASED PAINT TABULATION

RESULTS FOR CONCENTRATION AND

DESCRIPTION

LEAD BASED PAINT SAMPLE NEGATIVE (<1

mg cm

², EPA HUD STANDARD FOR LOW INCOME HOUSING.)

LEAD BASED PAINT SAMPLE POSITIVE (>1

mg cm

²)

Note:

Any level of lead in paint may still pose an OSHA health hazard if mishandled.

REFERENCED GRIDLINES

BAGHOUSE

BAGHOUSE

CHEMICAL STORAGE AREA TO

BE INCLUDED IN WP AREA

CLASSIFICATION HOWEVER

DETECTORS INSTALLED SHALL

BE THE SAME TYPE INSTALLED

IN THE CLASS II DIV 1 AREAS

OPEN TO BELOW

ROOF

BAGHOUSE

BAGHOUSE

OPEN TO BELOW

OPEN TO BELOW

BAGHOUSE BAGHOUSE

ROOF

ROOF

ROOF

F500 NO SCALE

F500 NO SCALE

F500 NO SCALE

F500 NO SCALE

F500 NO SCALE

F500 NO SCALE

F500 NO SCALE

F500 NO SCALE

CLASS II DIV 1 GROUP F AREA

UNCLASSIFIED AREA, BUT EQUIPMENT TO BE INSTALLED AS WEATHERPROOF TO

INCLUDE RACEWAYS, BACK BOXES, CONNECTIONS AND SHALL ALSO INCLUDE

SECONDARY ENCLOSURES FOR ANY PACKAGED EQUIPMENT WHICH IS PROVIDED IN

NEMA 1 TYPE ENCLOSURES TO PROVIDE ADDITIONAL PROTECTION FROM DUST

INFILTRATION INTO THESE COMPONENTS, DEVICES AND/OR ANCILLARY SYSTEMS

CLASS I DIV 2 GROUP D AREA

UNCLASSIFIED AREA

EAST

FILTRATION

BUILDING

COAL

THAWING

ROOM

ELEV. 575'-6"

ELEV. 581'-2"

ELEV. 600'-0"

ELEV. 616'-0"

WEST

FILTRATION

BUILDING

ELEV. 578'-3"

ELEV. 543'-9"

ELEV. 636'-0"

B

TRIPPER

ROOM

CRANE

ELEV. 543'-9" ELEV. 543'-9"

ELEV. 556'-2"

ELEV. 581'-2"

ELEV. 600'-0"

ELEV. 616'-0"

TRIPPER

ROOM

EAST

FILTRATION

BUILDING

COAL

THAWING

ROOM

ELEV. 575'-6"

ELEV. 556'-2"

ELEV. 545'-6"

ELEV. 531'-0"

ELEV. 581'-2"

ELEV. 600'-0"

ELEV. 616'-0"

WEST

FILTRATION

BUILDING

ELEV. 571'-3"

ELEV. 575'-6" ELEV. 578'-3"ELEV. 578'-3"

TURBINE

GENERATOR

ROOM

AREA CLASSIFICATION: AREA CLASSIFICATION:

AREA CLASSIFICATION: AREA CLASSIFICATION: AREA CLASSIFICATION:

AREA CLASSIFICATION: AREA CLASSIFICATION:

GENERAL SHEET F500 NOTES

1. COAL HANDLING AREAS ARE AT VARIOUS ELEVATIONS WITH EXTERNAL CONVEYORS ARE NOT LEVEL.

2. AREA CLASSIFICATIONS BASED ON TYPES OF MATERIALS NORMALLY PRESENT AT THE LOCATIONS, i.e. PREDOMINANTLY COAL DUSTS. OTHER NON EXPLOSIVE BASED DUSTS AND DIRT ARE ALSO PRESENT WITHIN THE PLANT AREAS WHERE DEVICES ARE NOTED TO HAVE WEATHERPROOF ENCLOSURES TO PREVENT THIS DUST INFILTRATION INTO THESE SYSTEMS.

3. AREA CLASSIFICATIONS FOR THE SORBENT FACILITIES HAS NOT BEEN VERIFIED AS THESE LOCATIONS ARE STILL NOT COMPLETED AND TURNED OVER TO THE GOVERNMENT AND AS SUCH AS-BUILT INFORMATION IS NOT AVAILABLE. SHEET 11 OF 12

WASHDOWN AREA

FOR REFERENCE ONLY

EE-10223

Electric Panels Ph A Dwg Sched
CH&PP Electric Ph A Drawings
Binder4
H1-H2 Issued for Const.