The document provides clarification on two specific questions submitted by contractors. Regarding the reuse of existing hollow metal frames grouted into CMU (concrete masonry units), the Government response explicitly states that new frames are required. The contractor had proposed reusing frames in good condition with repainting to avoid extensive removal work and potential damage to the CMU and building structure. Regarding a second inquiry about repairing damaged frames with minor rust using bondo as an alternative to removal, the Government again clarified that new frames are required. The document confirms that frames must be replaced along with the hollow metal doors, and that saw cutting may be required to accomplish the removal work.

View the file

Other files

Show all 16

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Multi Facility Doors

Is it acceptable to reuse the hollow metal frames that are grouted into CMU? If the frames are in good condition, they could just be repainted. Work to remove the frames grouted in the CMU will be extensive/there is the possibility we damage CMU/building/etc trying to cut the frames out.

Frames need to be replaced along with the hollow metal doors. Saw cutting could be required.

If there are frames that are damaged/have minor rust/etc is it acceptable to repair the frames using bondo and leave the frames in place? We possibly could repair the frames so they would not need to be removed.

New frames are required.