16 Mechanical Drawings.pdf
PDF 680 KB Posted
- Attached to
- Repair Building 1330 Main Sewage Line
- Solicitation number
- FA489725B0008
About this file
These are mechanical design drawings for a restroom remodel project at Building 1330, Mountain Home Air Force Base, located in Mountain Home, Idaho. The documents include detailed plans for HVAC, plumbing, and demolition work, with specific technical specifications covering exhaust fan replacement, domestic water system modifications, waste and vent line adjustments, and water heater installation. The drawings, prepared by Hutchison Smith Architects in October 2021, provide comprehensive technical guidance for contractors, including general project notes requiring code compliance, seismic bracing, trap primers for floor drains, and coordination with other trades. The mechanical sheets include demolition plans, equipment schedules, legends, abbreviations, and technical details for executing the restroom renovation work.
View the file
Other files
Show all 22
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
B U
IL
D
IN
G
R
ES
TR
O
O M
R
EM
O D
EL
F
O R
OCT. 2021
21-156 1330 - M0.0
TH
ES
E D
ES
IG
N S
A N
D D
R A
W
IN
G S
A R
E
TH
E
EX
C
LU
SI
V
E P
R O
P
ER
TY
O
F H
U
TC
H
IS
O N
S M
IT
H
A R
C H
IT
EC
TS
, A
N D
A R
E N
O T
TO
B
E U
SE
D
O R
D U
P
LI
C A
TE
D
W
IT
H O
U T
P
ER
M
IS
SI
O
N . C
O P
Y R
IG
H
T
1, A
LL
R
IG
H
TS
R
ES
ER
V
ED
DRAWN:
PROJECT:
DATE:
FILE:
REVISIONS:
SHEET NO.
MO
UN
TA
IN
H
OM
E
AI
R
FO
R& E
BA
SE
M O
U N
TA
IN
H O
M E
ID
A
H O
HUTCHISON
SMITH
ARCHITECTS
270 North 27th Street Boise, ID. 83702 (208) 338-1212 FAX (208) 338-0011 hsaarchitects.com
D E
S
IG
N B
U
IL
D C
O N
T R
A C
T O
R C
-2 C
O N
S T
R U
C T
IO
N
S . 1
8T H
W S
T R
E E
T
M O
U N
T A
IN
H
O M
E , I
D . 8
THESE DOCUMENTS HAVE BEEN UPDATED AND ALTERED
BASED ON INFORMATION PROVIDED BY OTHERS. THE
ARCHITECT/ENGINEER HAS NOT VERIFIED THE ACCURACY
OF THIS INFORMATION AND SHALL NOT BE HELD
RESPONSIBLE FOR ANY ERRORS OR OMISSIONS WHICH
MAY BE INCORPORATED HEREIN AS A RESULT.
BY: BR DATE: 2/7/23
ORIGINAL SIGNED AND
SEALED DRA:INGS ON
FILE AT 9ALUE
ENGINEERING 11� E
&ALDER:OOD STE 101 DR.
BOISE ID �3���
GENERAL PROJECT NOTES
1. CONTRACTOR TO VERIFY EQUIPMENT LOCATIONS, DIMENSIONS, AND
COORDINATE ALL WORK WITH OTHER TRADES PRIOR TO THE START OF
CONSTRUCTION.
2. ALL DIMENSIONS ARE IN INCHES UNLESS OTHERWISE NOTED.
3. ALL WORK IS TO BE IN COMPLIANCE WITH CURRENT CODES AS ADOPTED
AND AMENDED BY THE LOCAL JURISDICTION. PROVIDE ALL LABOR AND
MATERIAL AS NECESSARY TO MEET THE CURRENT ADOPTED CODES.
4. RECORD DRAWINGS OF THE INSTALLATION ARE REQUIRED TO BE
PROVIDED BY THE CONTRACTOR WITHIN 30 DAYS OF SUBSTANTIAL
COMPLETION. REDLINES OF AS-BUILT PLANS AND SPECIFICATIONS ARE
ACCEPTABLE.
5. PROVIDE OPERATION AND MAINTENANCE MANUALS WITHIN 30 DAYS OF
SUBSTANTIAL COMPLETION OF ALL EQUIPMENT INSTALLED.
6. INSTALL ALL EQUIPMENT, PIPING, AND DUCTWORK SEISMICALLY BRACED
PER CODE, MANUFACTURER RECOMMENDATIONS, OR STANDARD
CONSTRUCTION PRACTICES, WHICHEVER IS MORE STRINGENT.
7. PROVIDE TRAP PRIMERS FOR ALL FLOOR DRAINS AND FLOOR SINKS.
8. INSTALL ALL WATER LINES ON EXTERIOR WALLS, INCLUDING LINES IN
ATTIC OR ROOF, ON WARM SIDE (INSIDE) OF INSULATION.
MECHANICAL SHEET INDEX
# SHEET NAME
M0.0 HVAC COVER SHEET
M1.1 HVAC PLAN
PLUMBING / HYDRONIC LEGEND
PIPE CONTINUATION
PIPE RISE
PIPE DROP
PIPE CAP
PT PORT
TEMPERATURE GAUGE
PRESSURE GAUGE
TEMPERATURE SENSOR
PRESSURE SENSOR
STRAINER
UNION
GLOBE VALVE
BUTTERFLY VALVE
BALL VALVE
CHECK VALVE
WATER METER
CIRCUIT SETTER
REDUCED PRESSURE BACKFLOW PREVENTER
DOUBLE CHECK BACKFLOW PREVENTER
SINGLE BOWL FLEX CONNECTOR
DOUBLE BOWL FLEX CONNECTOR
PRESSURE RELIEF VALVE
HOSE BIBB
WALL/FLOOR CLEAN OUT
CLEAN OUT TO GRADE
ROOF OVERFLOW DRAIN SCUPPER
GAS REGULATOR
DOMESTIC COLD WATER
DOMESTIC HOT WATER
WASTE
VENT
GAS
POINT OF CONNECTION
POINT OF DEMOLITION
T
P
DCW
DHW
W
V
G
ABBREVIATIONS
SYMBOL DESCRIPTION
°F DEGREES FAHRENHEIT
ACT ACOUSTICAL CEILING TILE
AL ACOUSTIC LINING
ALT ALTERNATIVE
ASME AMERICAN SOCIETY OF MECHANICAL ENGINEERS
BHP BRAKE HORSEPOWER
BMS BUILDING MANAGEMENT SYSTEM
CHAR CHARACTERISTICS
COP COEFFICIENT OF PERFORMANCE
CV CONSTANT VOLUME
DB DRY BULB
DBA DECIBEL
EA EXHAUST AIR
EER ENERGY EFFICIENCY RATIO
EFF EFFECTIVENESS
ENT ENTERING
ESP EXTERNAL STATIC PRESSURE (INCHES W.G.)
EVAP EVAPORATOR
EWT ENTERING WATER TEMPERATURE
(E) EXISTING
FLA FULL LOAD AMPS
FM FREQUENCY MODULATION
FT FEET
GPM GALLONS PER MINUTE
HP HORSEPOWER
HR HEAT RECOVERY
HS HEAT SUPPLY
HVAC HEATING, VENTILATION AND AIR CONDITIONING
HSPF HEATING SEASONAL PERFORMANCE FACTOR
IN INCH
KW KILOWATTS
LB POUNDS
LVG LEAVING
LWT LEAVING WATER TEMPERATURE
MAX MAXIMUM
MBH BTUH'S IN THOUSANDS
MC MECHANICAL CONTRACTOR
MCA MINIMUM CIRCUIT AMPACITY
MECH MECHANICAL
MFR MANUFACTURER
MOD MOTOR OPERATED DAMPER; MODULATING
NC NOISE CRITERIA
NG NATURAL GAS
NIC NOT IN CONTRACT
NO. NUMBER
NTS NOT TO SCALE
OA OUTSIDE AIR
OP OPERATING
PG PROPYLENE GLYCOL
POC POINT OF CONNECTION
PRV PRESSURE REDUCING VALVE
PSI POUNDS PER SQUARE INCH
PSIG POUNDS PER SQUARE INCH GAUGE
RAT RETURN AIR TEMPERATURE
RCP REFLECTED CEILING PLAN
RPM REVOLUTIONS PER MINUTE
SENS SENSIBLE
SEER SEASONAL ENERGY EFFICIENCY RATING
SF SQUARE FOOTAGE
F/SD FIRE/SMOKE DAMPER
SPE STATIC PRESSURE EXTERNAL (INCHES W.G.)
SP STATIC PRESSURE (INCHES W.G.)
SQFT SQUARE FEET
SS STAINLESS STEEL
S/T SENSIBLE TO TOTAL COOLING RATIO
SW SOFT WATER
TDH TOTAL DYNAMIC HEAD
TEMP TEMPERATURE
THD TOTAL HARMONIC DISTORTION
TSP TOTAL STATIC PRESSURE
TYP TYPICAL
VFD VARIABLE FREQUENCY DRIVE
VTR VENT THROUGH ROOF
VS VERSUS
WPD WATER PRESSURE DROP (FT HEAD)
WC WATER COLUMN
W.G. WATER GAUGE
EXHAUST FAN SCHEDULE
NO. AREA
SERVED CFM SPE WATTAGE
OR HP CHAR SONES TYPE MANUFACTURER REMARKS
1 RESTROOM 280 0.25 88.1 W 115/1Ø 3.5 CEILING FAN 'COOK' GC 1, 2
2 RESTROOM 140 0.25 43.4 W 115/1Ø 3.5 CEILING FAN 'COOK' GC 1, 2
EF
INTERLOCK FAN WITH LIGHT SWITCH.
PROVIDE BACK DRAFT DAMPER, BIRD SCREEN, HANGING ISOLATION KIT, ROOF CAP, AND PLUG DISCONNECT IF
EXISTING IS NOT SALVAGEABLE.
DUCT CONSTRUCTION TABLE
SYSTEM
DUCT PRESSURE CLASS IN INCHES OF WATER COLUMN DUCT TYPE DUCT TEST PRESSURE:
INCHES OF WATER
COLUMN
REMARKS
SUPPLY DUCT RETURN DUCT EXHAUST DUCT OUTSIDE AIR DUCT
ROUND/OVAL RECTANGULAR
DUCT SEAL CLASS DUCT LEAK CLASS DUCT SEAL CLASS DUCT LEAK CLASS
EXHAUST
DUCT - - -1 - A 24 - - -1 1
TEST IN ACCORDANCE WITH UFGS 23 05 93, TESTING, ADJUSTING, AND BALANCING FOR HVAC AND THE PROCEDURES IN SMACNA HVAC AIR DUCT LEAKAGE TEST MANUAL.1
AutoCAD SHX Text M0.0
AutoCAD SHX Text
HVAC COVER SHEET
AutoCAD SHX Text
HVAC COVER SHEET
AutoCAD SHX Text
HVAC COVER SHEET
AutoCAD SHX Text
HVAC COVER SHEET
L-1
L-1
L-1L-1
WC-1
WC-1 WC-1
WC-1
4(E) DCW MAIN (E) DCW MAIN
U-1
U-1
SS-1
2 2 2 2
B U
IL
D
IN
G
R
ES
TR
O
O M
R
EM
O D
EL
F
O R
OCT. 2021
21-156 1330 - P1.2
TH
ES
E D
ES
IG
N S
A N
D D
R A
W
IN
G S
A R
E
TH
E
EX
C
LU
SI
V
E P
R O
P
ER
TY
O
F H
U
TC
H
IS
O N
S M
IT
H
A R
C H
IT
EC
TS
, A
N D
A R
E N
O T
TO
B
E U
SE
D
O R
D U
P
LI
C A
TE
D
W
IT
H O
U T
P
ER
M
IS
SI
O
N . C
O P
Y R
IG
1, A
LL
R
IG
H
TS
R
ES
ER
V
ED
DRAWN:
PROJECT:
DATE:
FILE:
REVISIONS:
SHEET NO.
MO
UN
TA
IN
H
OM
E
AI
R
FO
R& E
BA
SE
M O
U N
TA
IN
H O
M E
ID
A
H O
HUTCHISON
SMITH
ARCHITECTS
270 North 27th Street Boise, ID. 83702 (208) 338-1212 FAX (208) 338-0011 hsaarchitects.com
D E
S
IG
N B
U
IL
D C
O N
T R
A C
T O
R C
-2 C
O N
S T
R U
C T
IO
N
S . 1
8T H
W S
T R
E E
T
M O
U N
T A
IN
H
O M
E , I
D . 8
THESE DOCUMENTS HAVE BEEN UPDATED AND ALTERED
BASED ON INFORMATION PROVIDED BY OTHERS. THE
ARCHITECT/ENGINEER HAS NOT VERIFIED THE ACCURACY
OF THIS INFORMATION AND SHALL NOT BE HELD
RESPONSIBLE FOR ANY ERRORS OR OMISSIONS WHICH
MAY BE INCORPORATED HEREIN AS A RESULT.
BY: BR DATE: 2/7/23
ORIGINAL SIGNED AND
SEALED DRA:INGS ON
FILE AT 9ALUE
ENGINEERING 11� E
&ALDER:OOD STE 101 DR.
BOISE ID �3���
KEYNOTES
DEMOLISH EXISTING URINAL AND PLUMBING CONNECTIONS TO WALL.
REPAIR WALLS, FLOORS, ETC AS NECESSARY TO MEET ARCHITECTURAL
SPECIFICATIONS. ENSURE CARE IS TAKEN TO REUSE AS MUCH EXISTING
AS POSSIBLE. RECYCLE MATERIALS AS CAPABLE.
DEMOLISH EXISTING WATER CLOSET AND PLUMBING CONNECTIONS
TO WALL. REPAIR WALLS, FLOORS, ETC AS NECESSARY TO MEET
ARCHITECTURAL SPECIFICATIONS. ENSURE CARE IS TAKEN TO REUSE AS
MUCH EXISTING AS POSSIBLE. RECYCLE MATERIALS AS CAPABLE.
DEMOLISH EXISTING LAVATORY AND PLUMBING CONNECTIONS TO
WALL. REPAIR WALLS, FLOORS, ETC AS NECESSARY TO MEET
ARCHITECTURAL SPECIFICATIONS. ENSURE CARE IS TAKEN TO REUSE AS
MUCH EXISTING AS POSSIBLE. RECYCLE MATERIALS AS CAPABLE.
RELOCATE DCW DROP FROM EXISTING LOCATION TO NEW LOCATION.
KEEP ROUTING AND SIZING THE SAME.
DEMOLISH EXISTING SERVICE SINK AND PLUMBING CONNECTIONS TO
WALL. REPAIR WALLS, FLOORS, ETC AS NECESSARY TO MEET
ARCHITECTURAL SPECIFICATIONS. ENSURE CARE IS TAKEN TO REUSE AS
MUCH EXISTING AS POSSIBLE. RECYCLE MATERIALS AS CAPABLE.
EXTEND EXISTING DCW AND DHW DROPS TO NEW WALL LOCATION.
64'2'0' 8'
SCALE: 3/8"=1'
P1.2
DOMESTIC WATER DEMO PLAN
4'2'0' 8'
SCALE: 3/8"=1'
P1.2
DOMESTIC WATER PLAN
GENERAL NOTES
1. EXISTING SHOWN LIGHT, NEW WORK SHOWN DARK.
2. ALL DIMENSIONS ARE IN INCHES UNLESS OTHERWISE NOTED.
3. COORDINATE ALL WORK WITH OTHER TRADES.
4. GRADE FOR DRAIN LINES SHALL BE 1/4" PER FT MINIMUM UNLESS
OTHERWISE NOTED.
5. INSTALL ALL WORK PER LOCAL CODES AS A MINIMUM STANDARD. IF
PLANS REFLECT SCOPE THAT EXCEEDS CODE REQUIREMENTS, INSTALL
WORK PER THE HIGHER STANDARD.
6. INSTALL CLEANOUTS AT THE BASE OF ALL WASTE AND ROOF DRAIN
STACKS.
7. PROVIDE AN APPROVED FIRE STOP ASSEMBLY FOR ANY PIPING
PENETRATING RATED ASSEMBLIES.
8. REFERENCE ARCHITECTURAL PLANS FOR MOUNTING HEIGHTS AND
LOCATIONS OF PLUMBING ITEMS.
9. PROVIDE TRAP PRIMERS FOR ALL FLOOR DRAINS AND FLOOR SINKS.
10. PROVIDE WATER HAMMER ARRESTORS FOR ALL SOLENOID VALVES AND
QUICK CLOSING VALVES ON LINES OVER 1/2".
11. DEMO ALL UNUSED EXISTING PIPING WITHIN PROJECT FOOTPRINT WHILE
MAINTAINING FUNCTIONALITY OF REMAINING FACILITY.
AutoCAD SHX Text P1.2
DOMESTIC WATER PLAN
EF
EF
(E) EA
(E) EA
2 2
(E) EA (E) EA
B U
IL
D
IN
G
R
ES
TR
O
O M
R
EM
O D
EL
F
O R
OCT. 2021
21-156 1330 - M1.1
TH
ES
E D
ES
IG
N S
A N
D D
R A
W
IN
G S
A R
E
TH
E
EX
C
LU
SI
V
E P
R O
P
ER
TY
O
F H
U
TC
H
IS
O N
S M
IT
H
A R
C H
IT
EC
TS
, A
N D
A R
E N
O T
TO
B
E U
SE
D
O R
D U
P
LI
C A
TE
D
W
IT
H O
U T
P
ER
M
IS
SI
O
N . C
O P
Y R
IG
1, A
LL
R
IG
H
TS
R
ES
ER
V
ED
DRAWN:
PROJECT:
DATE:
FILE:
REVISIONS:
SHEET NO.
MO
UN
TA
IN
H
OM
E
AI
R
FO
R& E
BA
SE
M O
U N
TA
IN
H O
M E
ID
A
H O
HUTCHISON
SMITH
ARCHITECTS
270 North 27th Street Boise, ID. 83702 (208) 338-1212 FAX (208) 338-0011 hsaarchitects.com
D E
S
IG
N B
U
IL
D C
O N
T R
A C
T O
R C
-2 C
O N
S T
R U
C T
IO
N
S . 1
8T H
W S
T R
E E
T
M O
U N
T A
IN
H
O M
E , I
D . 8
THESE DOCUMENTS HAVE BEEN UPDATED AND ALTERED
BASED ON INFORMATION PROVIDED BY OTHERS. THE
ARCHITECT/ENGINEER HAS NOT VERIFIED THE ACCURACY
OF THIS INFORMATION AND SHALL NOT BE HELD
RESPONSIBLE FOR ANY ERRORS OR OMISSIONS WHICH
MAY BE INCORPORATED HEREIN AS A RESULT.
BY: BR DATE: 2/7/23
ORIGINAL SIGNED AND
SEALED DRA:INGS ON
FILE AT 9ALUE
ENGINEERING 11� E
&ALDER:OOD STE 101 DR.
BOISE ID �3���
GENERAL NOTES
1. EXISTING DUCT, PIPE, AND EQUIPMENT SHOWN LIGHT. NEW WORK
SHOWN DARK.
2. ALL DIMENSIONS ARE IN INCHES UNLESS OTHERWISE NOTED.
3. COORDINATE ALL WORK WITH OTHER TRADES.
4. DUCT SIZES SHOWN ARE INTERIOR DIMENSIONS AND ARE MEASURED IN
INCHES UNLESS OTHERWISE NOTED.
5. LINE ALL DUCTWORK WITHIN 15' OF A SUPPLY FAN WITH 1" ACOUSTICAL
LINING.
6. COORDINATE EXACT LOCATIONS OF DUCT, DIFFUSERS, AND GRILLES WITH
REFLECTED CEILING, LIGHTING, AND FIRE PROTECTION LAYOUTS.
7. COORDINATE DUCT RUNS AND ROOFTOP PENETRATIONS WITH
STRUCTURAL AND ROOFING CONTRACTOR.
8. SEAL ALL PENETRATIONS THROUGH RATED ASSEMBLIES WITH U.L.
APPROVED FIRE-RATED SYSTEM.
9. ALL DUCTWORK TO BE CONSTRUCTED PER THE LATEST EDITION OF
SMACNA.
10. FLEX DUCT RUNOUTS ARE LIMITED TO 5'-0" MAXIMUM.
11. INSTALL ALL MECHANICAL EQUIPMENT WITH REQUIRED CLEARANCES AND
ACCESS.
12. DUCT MAINS AND EQUIPMENT LOCATED IN THE JOIST ARE TO BE
COORDINATED WITH STRUCTURAL. COORDINATE FOR REMOVING OF
BRACING AS REQUIRED.
13. ALL SQUARE TO ROUND WORK CONNECTIONS SHALL HAVE BELL MOUTHS
WITH STANDARD PRACTICE RADIUSES.
14. ALL DUCTWORK BEHIND RETURN GRILLES SHALL BE PAINTED FLAT BLACK.
15. PROVIDE FLUSH CUP REMOTE OPERATORS ON ALL DAMPERS LOCATED
ABOVE INACCESSIBLE CEILING.
KEYNOTES
CONNECT NEW EXHAUST FAN INTO EXISTING EXHAUST DUCT.
CONTRACTOR TO FIELD VERIFY MINIMUM OF 10Ø EA.
DEMO EXISTING EXHAUST FAN. ENSURE CARE IS TAKEN TO REUSE AS
MUCH EXISTING IS POSSIBLE. COORDINATE ELECTRICAL CONNECTION
DEMO WITH ELECTRICAL. RECYCLE MATERIALS AS CAPABLE.
4'2'0' 8'
SCALE: 3/8"=1'
M1.1
HVAC DEMO PLAN
4'2'0' 8'
SCALE: 3/8"=1'
M1.1
HVAC PLAN
AutoCAD SHX Text M1.1
HVAC PLAN
B U
IL
D
IN
G
R
ES
TR
O
O M
R
EM
O D
EL
F
O R
OCT. 2021
21-156 1330 - P0.0
TH
ES
E D
ES
IG
N S
A N
D D
R A
W
IN
G S
A R
E
TH
E
EX
C
LU
SI
V
E P
R O
P
ER
TY
O
F H
U
TC
H
IS
O N
S M
IT
H
A R
C H
IT
EC
TS
, A
N D
A R
E N
O T
TO
B
E U
SE
D
O R
D U
P
LI
C A
TE
D
W
IT
H O
U T
P
ER
M
IS
SI
O
N . C
O P
Y R
IG
1, A
LL
R
IG
H
TS
R
ES
ER
V
ED
DRAWN:
PROJECT:
DATE:
FILE:
REVISIONS:
SHEET NO.
MO
UN
TA
IN
H
OM
E
AI
R
FO
R& E
BA
SE
M O
U N
TA
IN
H O
M E
ID
A
H O
HUTCHISON
SMITH
ARCHITECTS
270 North 27th Street Boise, ID. 83702 (208) 338-1212 FAX (208) 338-0011 hsaarchitects.com
D E
S
IG
N B
U
IL
D C
O N
T R
A C
T O
R C
-2 C
O N
S T
R U
C T
IO
N
S . 1
8T H
W S
T R
E E
T
M O
U N
T A
IN
H
O M
E , I
D . 8
THESE DOCUMENTS HAVE BEEN UPDATED AND ALTERED
BASED ON INFORMATION PROVIDED BY OTHERS. THE
ARCHITECT/ENGINEER HAS NOT VERIFIED THE ACCURACY
OF THIS INFORMATION AND SHALL NOT BE HELD
RESPONSIBLE FOR ANY ERRORS OR OMISSIONS WHICH
MAY BE INCORPORATED HEREIN AS A RESULT.
BY: BR DATE: 2/7/23
ORIGINAL SIGNED AND
SEALED DRA:INGS ON
FILE AT 9ALUE
ENGINEERING 11� E
&ALDER:OOD STE 101 DR.
BOISE ID �3���
GENERAL PROJECT NOTES
1. CONTRACTOR TO VERIFY EQUIPMENT LOCATIONS, DIMENSIONS, AND
COORDINATE ALL WORK WITH OTHER TRADES PRIOR TO THE START OF
CONSTRUCTION.
2. ALL DIMENSIONS ARE IN INCHES UNLESS OTHERWISE NOTED.
3. ALL WORK IS TO BE IN COMPLIANCE WITH CURRENT CODES AS ADOPTED
AND AMENDED BY THE LOCAL JURISDICTION. PROVIDE ALL LABOR AND
MATERIAL AS NECESSARY TO MEET THE CURRENT ADOPTED CODES.
4. RECORD DRAWINGS OF THE INSTALLATION ARE REQUIRED TO BE
PROVIDED BY THE CONTRACTOR WITHIN 30 DAYS OF SUBSTANTIAL
COMPLETION. REDLINES OF AS-BUILT PLANS AND SPECIFICATIONS ARE
ACCEPTABLE.
5. PROVIDE OPERATION AND MAINTENANCE MANUALS WITHIN 30 DAYS OF
SUBSTANTIAL COMPLETION OF ALL EQUIPMENT INSTALLED.
6. INSTALL ALL EQUIPMENT, PIPING, AND DUCTWORK SEISMICALLY BRACED
PER CODE, MANUFACTURER RECOMMENDATIONS, OR STANDARD
CONSTRUCTION PRACTICES, WHICHEVER IS MORE STRINGENT.
7. PROVIDE TRAP PRIMERS FOR ALL FLOOR DRAINS AND FLOOR SINKS.
8. INSTALL ALL WATER LINES ON EXTERIOR WALLS, INCLUDING LINES IN
ATTIC OR ROOF, ON WARM SIDE (INSIDE) OF INSULATION.
PLUMBING SHEET INDEX
# SHEET NAME
P0.0 PLUMBING COVER SHEET
P1.1 WASTE AND VENT PLAN
P1.2 DOMESTIC WATER PLAN
PLUMBING / HYDRONIC LEGEND
PIPE CONTINUATION
PIPE RISE
PIPE DROP
PIPE CAP
PT PORT
TEMPERATURE GAUGE
PRESSURE GAUGE
TEMPERATURE SENSOR
PRESSURE SENSOR
STRAINER
UNION
GLOBE VALVE
BUTTERFLY VALVE
BALL VALVE
CHECK VALVE
WATER METER
CIRCUIT SETTER
REDUCED PRESSURE BACKFLOW PREVENTER
DOUBLE CHECK BACKFLOW PREVENTER
PRESSURE RELIEF VALVE
HOSE BIBB
WALL/FLOOR CLEAN OUT
CLEAN OUT TO GRADE
ROOF OVERFLOW DRAIN SCUPPER
DOMESTIC COLD WATER
DOMESTIC HOT WATER
WASTE
VENT
GAS
POINT OF CONNECTION
POINT OF DEMOLITION
T
P
DCW
DHW
W
V
G
ABBREVIATIONS
SYMBOL DESCRIPTION
°F DEGREES FAHRENHEIT
ACT ACOUSTICAL CEILING TILE
AL ACOUSTIC LINING
ALT ALTERNATIVE
ASME AMERICAN SOCIETY OF MECHANICAL ENGINEERS
BHP BRAKE HORSEPOWER
BMS BUILDING MANAGEMENT SYSTEM
CHAR CHARACTERISTICS
COP COEFFICIENT OF PERFORMANCE
CV CONSTANT VOLUME
DB DRY BULB
DBA DECIBEL
EA EXHAUST AIR
EER ENERGY EFFICIENCY RATIO
EFF EFFECTIVENESS
ENT ENTERING
ESP EXTERNAL STATIC PRESSURE (INCHES W.G.)
EVAP EVAPORATOR
EWT ENTERING WATER TEMPERATURE
(E) EXISTING
FLA FULL LOAD AMPS
FM FREQUENCY MODULATION
FT FEET
GPM GALLONS PER MINUTE
HP HORSEPOWER
HR HEAT RECOVERY
HS HEAT SUPPLY
HVAC HEATING, VENTILATION AND AIR CONDITIONING
HSPF HEATING SEASONAL PERFORMANCE FACTOR
IN INCH
KW KILOWATTS
LB POUNDS
LVG LEAVING
LWT LEAVING WATER TEMPERATURE
MAX MAXIMUM
MBH BTUH'S IN THOUSANDS
MC MECHANICAL CONTRACTOR
MCA MINIMUM CIRCUIT AMPACITY
MECH MECHANICAL
MFR MANUFACTURER
MOD MOTOR OPERATED DAMPER; MODULATING
NC NOISE CRITERIA
NG NATURAL GAS
NIC NOT IN CONTRACT
NO. NUMBER
NTS NOT TO SCALE
OA OUTSIDE AIR
OP OPERATING
PG PROPYLENE GLYCOL
POC POINT OF CONNECTION
PRV PRESSURE REDUCING VALVE
PSI POUNDS PER SQUARE INCH
PSIG POUNDS PER SQUARE INCH GAUGE
RAT RETURN AIR TEMPERATURE
RCP REFLECTED CEILING PLAN
RPM REVOLUTIONS PER MINUTE
SENS SENSIBLE
SEER SEASONAL ENERGY EFFICIENCY RATING
SF SQUARE FOOTAGE
F/SD FIRE/SMOKE DAMPER
SPE STATIC PRESSURE EXTERNAL (INCHES W.G.)
SP STATIC PRESSURE (INCHES W.G.)
SQFT SQUARE FEET
SS STAINLESS STEEL
S/T SENSIBLE TO TOTAL COOLING RATIO
SW SOFT WATER
TDH TOTAL DYNAMIC HEAD
TEMP TEMPERATURE
THD TOTAL HARMONIC DISTORTION
TSP TOTAL STATIC PRESSURE
TYP TYPICAL
VFD VARIABLE FREQUENCY DRIVE
VTR VENT THROUGH ROOF
VS VERSUS
WPD WATER PRESSURE DROP (FT HEAD)
WC WATER COLUMN
W.G. WATER GAUGE
ELECTRIC WATER HEATER SCHEDULE
NO. TYPE
CAPACITY
(GAL)
HEATING
EWT (°F) LWT (°F)
GPH
RECOVERY @
90F RISE
RELIEF PRESSURE
(PSI)
UNIFORM
ENERGY
FACTOR
ELECTRICAL DIMENSIONS
WEIGHT
(LB) MANUFACTURER REMARKS
KW # ELEMENTS VOLTAGE PHASE DIA H
1 STORAGE TANK 50 4.5 2 50 140 20 150 0.93 208 1 24 48 144 'RHEEM' ELD 1, 2, 3, 4
WH
PROVIDE WITH DRAIN PAN AND INCOLOY ELEMENTS. SET ELEMENTS FOR SIMULTANEOUS OPERATION.
APPROVED BRAND ALTERNATES: A.O. SMITH, RHEEM, CONTACT ENGINEER WITH SUBMITTALS FOR ANY BRAND NOT LISTED
NOTE: WATER HEATER IS NOT SHOWN ON PLANS. CONTRACTOR TO FIELD VERIFY LOCATION PRIOR TO REPLACEMENT.
COORDINATE NEW DISCONNECT, LOCKABLE BREAKER PER NEC 422.31B, AND CONDUCTORS/CONDUITS WITH ELECTRICAL.
PLUMBING FIXTURE SCHEDULE
SYMBOL DESCRIPTION COLD WATER LINE SIZE HOT WATER LINE SIZE WASTE LINE SIZE VENT LINE SIZE
WC-1 WATER CLOSET (FLUSH VALVE, WALL MOUNTED, ADA COMPLIANT) 3/4" - 3" 2"
L-1 DROP IN LAVATORY (ADA COMPLIANT) 1/2" 1/2" 2" 1-1/2"
U-1 URINAL ( WASH DOWN) 3/4" - 2" 1-1/2"
SS-1 SERVICE SINK 1/2" 1/2" 2" 1-1/2"
WC-1 WATER CLOSET (FLUSH VALVE, WALL MOUNTED, ADA COMPLIANT): FIXTURE: KOHLER K-4325, SEAT: K-4731-GC-0. VITREOUS CHINA; FLOOR MOUNTED, FLUSH VALVE, 1.28 GPM/FLUSH. SECURE PIPING SERVING FLUSHOMETER VALVE IN WALL. PROVIDE WITH WHITE OPEN FRONT SEAT, BOLT CAPS, CLOSET SWEEP, SEAT FLANGE AND GASKET. PROVIDE SLOAN ROYAL 111-SMO SENSOR OPERATED BATTERY POWERED FLUSH VALVE. PROVIDE WITH WALL CARRIER SUITED TO WALL. COORDINATE WITH CONDITIONS PRIOR TO
ORDERING. PROVIDE ALL REQUIRED ACCESSORIES AND MOUNT PER ADA REQUIREMENTS.
L-1 DROP IN LAVATORY (ADA COMPLIANT): KOHLER K-R2196-4 "PENNINGTON" LAVATORY WITH DELTA 590 TOUCHLESS FAUCET WITH 0.5 GPM VANDAL RESISTANT AERATOR AND BATTERY, GRID STRAINER, 18 GA. CHROME PLATED P-TRAP, TAILPIECE AND 1/4 TURN STOPS. PROVIDE OWNER APPROVED SCREENING FOR ALL EXPOSED PIPEWORK UNDER COUNTER. PROVIDE ADA COMPLIANT INSULATION KIT, FASTENERS FOR TRAP, AND HOT AND COLD WATER ANGLE STOP VALVES. PROVIDE ALL REQUIRED ACCESSORIES AND INSTALL TO MEET ALL ADA REQUIREMENTS. PROVIDE WITH ASSE 1070 COMPLIANT TERMPERATURE REDUCING VALVES LIMITING TEMPERATURE AT 110F.
U-1 URINAL (WASH DOWN): KOHLER K-4991-ETSS-0 "BARDON" WITH SLOAN ROYAL 186-SMO, 0.5 GPF BATTERY OPERATED SENSOR FLUSH VALVE WITH MECHANICAL OVERRIDE.
SECURE PIPING IN WALL SERVING FLUSH VALVE. PROVIDE WITH FIXTURE CARRIER. PROVIDE "WHITE" COLOR SELECTION FOR CHINA. PROVIDE ALL REQUIRED ACCESSORIES AND
INSTALL TO MEET ALL ADA REQUIREMENTS.
SS-1 SERVICE SINK: KOHLER K-6710 WITH K-8940 RIM GUARD, K-9146 PERFORATED STRAINER, K-8928 FAUCET WITH VACUUM BREAKER, LOOSE KEY STOPS, HOSE AND WALL HOOK.
TAKE CARE TO REUSE EXISTING WASTE, VENT, AND DOMESTIC WATER CONNECTIONS.
WH-#
SCALE: NTS
WATER HEATER DETAIL
P0.0
(E) DOMESTIC COLD WATER SUPPLY
THERMOMETER
(TYP)
(E) DOMESTIC HOT WATER RECIRC
(E) DOMESTIC HOT WATER SUPPLY
AMTROL ST-5
EXPANSION TANK
STRAP TO WALL.
T
AUQUASTAT
P
1 HEAT CHECK
MANUFACTURERS DRAIN PAN
PRESSURE RELIEF VALVE
CASH ACME
HEAT GUARD 110-D TEMPERING VALVE
SET TO 120°F
WATER HEATER STAND
PUMP SCHEDULE
NO. TYPE GPM
HEAD
(FT) WATTS CHAR RPM SYSTEM WEIGHT MANUFACTURER REMARKS
1 POTABLE WATER CIRCULATOR - - - - - HOT WATER RECIRC - - 1
P
EXISTING TO REMAIN.1
AutoCAD SHX Text P0.0
PLUMBING COVER SHEET
(E) VENT MAIN
(E) WASTE MAIN
(E) VENT MAIN
(E) WASTE MAIN
4" W 4" W2" V 2" V
L-1 L-1
L-1L-1
WC-1
WC-1 WC-1
WC-1
U-1
U-1
SS-1
7 78
(E) VENT MAIN
(E) WASTE MAIN
(E) VENT MAIN
(E) WASTE MAIN
22 2 2
B U
IL
D
IN
G
R
ES
TR
O
O M
R
EM
O D
EL
F
O R
OCT. 2021
21-156 1330 - P1.1
TH
ES
E D
ES
IG
N S
A N
D D
R A
W
IN
G S
A R
E
TH
E
EX
C
LU
SI
V
E P
R O
P
ER
TY
O
F H
U
TC
H
IS
O N
S M
IT
H
A R
C H
IT
EC
TS
, A
N D
A R
E N
O T
TO
B
E U
SE
D
O R
D U
P
LI
C A
TE
D
W
IT
H O
U T
P
ER
M
IS
SI
O
N . C
O P
Y R
IG
1, A
LL
R
IG
H
TS
R
ES
ER
V
ED
DRAWN:
PROJECT:
DATE:
FILE:
REVISIONS:
SHEET NO.
MO
UN
TA
IN
H
OM
E
AI
R
FO
R& E
BA
SE
M O
U N
TA
IN
H O
M E
ID
A
H O
HUTCHISON
SMITH
ARCHITECTS
270 North 27th Street Boise, ID. 83702 (208) 338-1212 FAX (208) 338-0011 hsaarchitects.com
D E
S
IG
N B
U
IL
D C
O N
T R
A C
T O
R C
-2 C
O N
S T
R U
C T
IO
N
S . 1
8T H
W S
T R
E E
T
M O
U N
T A
IN
H
O M
E , I
D . 8
THESE DOCUMENTS HAVE BEEN UPDATED AND ALTERED
BASED ON INFORMATION PROVIDED BY OTHERS. THE
ARCHITECT/ENGINEER HAS NOT VERIFIED THE ACCURACY
OF THIS INFORMATION AND SHALL NOT BE HELD
RESPONSIBLE FOR ANY ERRORS OR OMISSIONS WHICH
MAY BE INCORPORATED HEREIN AS A RESULT.
BY: BR DATE: 2/7/23
ORIGINAL SIGNED AND
SEALED DRA:INGS ON
FILE AT 9ALUE
ENGINEERING 11� E
&ALDER:OOD STE 101 DR.
BOISE ID �3���
KEYNOTES
DEMOLISH EXISTING URINAL AND PLUMBING CONNECTIONS TO WALL.
REPAIR WALLS, FLOORS, ETC AS NECESSARY TO MEET ARCHITECTURAL
SPECIFICATIONS. ENSURE CARE IS TAKEN TO REUSE AS MUCH EXISTING
AS POSSIBLE. RECYCLE MATERIALS AS CAPABLE.
DEMOLISH EXISTING WATER CLOSET AND PLUMBING CONNECTIONS.
REPAIR WALLS, FLOORS, ETC AS NECESSARY TO MEET ARCHITECTURAL
SPECIFICATIONS. ENSURE CARE IS TAKEN TO REUSE AS MUCH EXISTING
AS POSSIBLE. RECYCLE MATERIALS AS CAPABLE.
DEMOLISH EXISTING LAVATORY AND PLUMBING CONNECTIONS TO
WALL. REPAIR WALLS, FLOORS, ETC AS NECESSARY TO MEET
ARCHITECTURAL SPECIFICATIONS. ENSURE CARE IS TAKEN TO REUSE AS
MUCH EXISTING AS POSSIBLE. RECYCLE MATERIALS AS CAPABLE.
CONTRACTOR TO SCOPE AND VERIFY WASTE AND VENT LOCATIONS
PRIOR TO BEGINNING CONSTRUCTION. NOTIFY ENGINEERS OF ANY
DISCREPANCY PRIOR TO BEGINNING CONSTRUCTION.
DEMOLISH EXISTING LAUNDRY TUB AND PLUMBING CONNECTIONS TO
WALL. REPAIR WALLS, FLOORS, ETC AS NECESSARY TO MEET
ARCHITECTURAL SPECIFICATIONS. ENSURE CARE IS TAKEN TO REUSE AS
MUCH EXISTING AS POSSIBLE. RECYCLE MATERIALS AS CAPABLE.
TIE NEW WASTE AND VENT CONNECTIONS INTO EXISTING STUBS FOR
DEMOLISHED LAVATORIES.
ROUTE NEW WASTE INSIDE PLUMBING WALL. AVOID TRENCHING AS
POSSIBLE. CONTRACTOR TO FIELD VERIFY EXISTING WASTE LOCATION
AND TIE IN POINT PRIOR TO BEGINNING WORK.
TIE NEW SS-1 WASTE INTO EXISTING WASTE FROM DEMOLISHED
LAUNDRY TUB. REUSE EXISTING VENT CONNECTION AS POSSIBLE.
4'2'0' 8'
SCALE: 3/8"=1'
P1.1
WASTE AND VENT DEMO PLAN
4'2'0' 8'
SCALE: 3/8"=1'
P1.2
WASTE AND VENT PLAN
GENERAL NOTES
1. EXISTING SHOWN LIGHT, NEW WORK SHOWN DARK.
2. ALL DIMENSIONS ARE IN INCHES UNLESS OTHERWISE NOTED.
3. COORDINATE ALL WORK WITH OTHER TRADES.
4. GRADE FOR DRAIN LINES SHALL BE 1/4" PER FT MINIMUM UNLESS
OTHERWISE NOTED.
5. INSTALL ALL WORK PER LOCAL CODES AS A MINIMUM STANDARD. IF
PLANS REFLECT SCOPE THAT EXCEEDS CODE REQUIREMENTS, INSTALL
WORK PER THE HIGHER STANDARD.
6. INSTALL CLEANOUTS AT THE BASE OF ALL WASTE AND ROOF DRAIN
STACKS.
7. PROVIDE AN APPROVED FIRE STOP ASSEMBLY FOR ANY PIPING
PENETRATING RATED ASSEMBLIES.
8. REFERENCE ARCHITECTURAL PLANS FOR MOUNTING HEIGHTS AND
LOCATIONS OF PLUMBING ITEMS.
9. PROVIDE TRAP PRIMERS FOR ALL FLOOR DRAINS AND FLOOR SINKS.
10. PROVIDE WATER HAMMER ARRESTORS FOR ALL SOLENOID VALVES AND
QUICK CLOSING VALVES ON LINES OVER 1/2".
11. DEMO ALL UNUSED EXISTING PIPING WITHIN PROJECT FOOTPRINT WHILE
MAINTAINING FUNCTIONALITY OF REMAINING FACILITY.
AutoCAD SHX Text P1.1
WASTE AND VENT PLAN
| Sheets and Views |
| 1330 - M0.0-Layout1 |
| 1330 - P1.2-Layout1 |
| 1330 - M1.1-Layout1 |
| 1330 - P0.0-Layout1 |
| 1330 - P1.1-Layout1 |
File details come from the government source that posted it. Updated .