Macrotec Consulting, LLC.
9724 Mild Weather Ct. · Las Vegas, NV 89148 Phone: (702) 338-8213 · Fax: (702) 629-5677
Demolition Investigation Report Asbestos and Lead Based Paint Survey
Project Information:
Nellis Air Force Base Bldg. 601
Report Info:
Macrotec Project # 12522 February 10, 2012
Prepared For:
Vince Bowers 99th Civil Engineering Squadron – CES/CEV Nellis AFB, NV 89191
Prepared By:
Jason McAllister - Macrotec Consulting, LLC.
Table of Contents:
Introduction Scope of Services Site Description Sample Collection Methodology Sample Analysis Methodology Sample Assessment Recommendations Inspection Limitations
Appendix A Asbestos Assessment Appendix B Lead Assessment Appendix C Asbestos Sample Location Diagram Appendix C.1 Lead Sample Location Diagram Appendix D Asbestos Laboratory Report Appendix D.1 Lead Laboratory Report
Asbestos / Lead Survey Macrotec Project # 12522 Nellis Air Force Base – Bldg. 601 Page 2
INTRODUCTION
Macrotec Consulting performed an inspection for Asbestos-Containing Building Materials and Lead Based Paint on February 3 and February 7, 2012. The inspection was conducted for the project defined as: Demolition of building 601 at Nellis Air Force Base in Las Vegas, NV.
The intent of this inspection was to identify materials containing asbestos and lead based paint, within the subject site, that may be impacted during planned demolition activities. Macrotec’s inspection services were conducted at the request of Vince Bowers of the 99th Civil Engineering Squadron.
Jason McAllister, an EPA Lead Inspector, temporary certification #II1211-JRM- 3640, and a Nevada Asbestos Abatement Consultant, License No. IM0901, and Dustin McAllister, a certified lead inspector, License No. NV-I-16781-1, and a Nevada Asbestos Abatement Consultant, License No.IM0961, conducted these services for Macrotec Consulting.
SCOPE OF SERVICES
Asbestos
Macrotec’s inspection services were conducted to identify the presence of any materials containing asbestos pursuant to the requirements of NAC 618.960 and in accordance with the inspection requirements of the EPA’s: 40 CFR Part 61 National Emission Standard for Hazardous Air Pollutants (NESHAP).
These regulations outline inspection and abatement requirements for materials containing asbestos, prior to renovation and/or demolition activities.
Lead
Macrotec collected paint chip samples to identify the presence and content level of lead for compliance with the Occupational Safety and Health Administration’s (OSHA) and the Environmental Protection Agencies (EPA) regulatory requirements pertaining to worker protection and waste disposal.
SITE DESCRIPTION
The subject site included both the interior and exterior of a one-story building.
Macrotec’s inspection was limited to the location within the site planned for demolition as described above.
Nellis Air Force Base – Bldg. 601 Page 3
SAMPLE COLLECTION METHODOLOGY
An initial walk through of the subject site was conducted to identify homogeneous suspect materials containing asbestos and/or lead based paint, and their respective locations. This information was then used to develop a sample collection strategy.
Samples were collected by pre-wetting sample areas with water, then cutting or scraping the sample from the substrate with an appropriate sampling tool.
Whenever possible, samples were collected from areas previously damaged or deteriorating. To avoid potential contamination due to unknown asbestos and/or lead based paint content; no building systems, components, or structures were demolished to obtain samples of potentially hidden materials containing asbestos.
Each suspect bulk sample was sealed in its own zip lock plastic container and labeled with a unique identification number. Sampling tools were individually cleaned before and after each sample was collected to avoid sample cross contamination. Decontamination was accomplished using single use, pre-moistened cloths.
Samples were recorded on Macrotec’s chain-of-custody form. This form accompanied the samples to Triangle Enivronmental Service Center, Inc.
(TESC), located in Moseley, Virginia. The National Voluntary Laboratory Accreditation Program (NVLAP) accredits TESC for analysis of bulk building material samples for asbestos. The American Industrial Hygiene Association (AIHA) accredits Schneider Laboratories Inc. in Richmond Virginia, for analysis of paint chip samples for lead.
SAMPLE ANALYSIS METHODOLOGY
Asbestos
Suspect asbestos samples were subjected to analysis by polarized light microscopy (PLM). Bulk sample analysis was conducted in accordance with the EPA’s “Test Method for the Determination of Asbestos in Bulk Building Materials, EPA/600/R-93/116, 1993.
Lead
To determine lead content, the samples were submitted for analysis. Suspect paint chip samples were subjected to analysis in accordance with the EPA’s Method SW846-7420.
Nellis Air Force Base – Bldg. 601 Page 4
SAMPLE ASSESSMENT
Asbestos
Macrotec’s inspection of the subject site found Twenty Eight (28) separate suspect asbestos building materials, of which a total of Thirty Six (36) samples were collected and submitted for analysis.
The sample results indicated that the suspect materials were “None Detected” for asbestos content.
See Appendix A for a listing of the materials, material locations, samples, sample locations and results for this project.
Note: Macrotec utilized previous sampling data for the “Sheet Rock, Mud & Tape” samples collected in various surveys throughout the building, all of which indicated that the material has no asbestos.
Lead
Macrotec collected Forty (40) paint samples of the predominate paint colors within the subject site.
The following table summarizes the painted surfaces that were found to be lead based paint (results above 5,000 parts per million), the locations where the painted surface is located, and laboratory result. Nellis AFB may have further regulations for the handling of materials with paint over 600 parts per million, so those results are also included.
Painted Surface Description
Material Locations
Lab Result (Parts / Million)
Red Metal Pump This material is the building’s mechanical room. 55,754
See Appendix B for a listing of the painted surfaces, samples, sample locations and results for this project.
Note: Macrotec utilized two previous surveys of the paint on the exterior of the building, which both indicated that the paint on the exterior was all well under 600 parts per million.
Nellis Air Force Base – Bldg. 601 Page 5
RECOMMENDATIONS
Asbestos
No asbestos containing materials were identified in this investigation. If suspect materials are found during demolition activities outside what was identified in this report, stop work immediately until further testing can be completed.
Lead
US EPA OSHA regulations require the implementation of worker protection if there is a potential that paint with lead in it will be disturbed during renovation activities. In accordance with these regulations Macrotec recommends:
Hiring an EPA Licensed Lead Consultant to develop a project specification based on this investigation and any other additional findings.
Hiring an EPA Licensed Lead Abatement Contractor to stabilize and/or remove all regulated lead painted materials.
Hiring an EPA Licensed Lead Consultant to monitor the removal activities and provide final clearance inspection reports.
INSPECTION LIMITATIONS
The information contained in this report is limited to those areas and suspect materials found to be visually accessible through reasonable means.
Note: The pool area was occupied / in use at the time of the investigation, limiting the availability of some materials and areas.
Macrotec conducted a non-destructive survey. No demolition of building materials was conducted to determine the presence of asbestos in wall cavities, chases or other inaccessible areas. Macrotec cannot warrant that these areas do not contain asbestos in locations other than those noted in this report, however, a good faith effort was made to conduct a comprehensive survey.
• Macrotec accepts no liability for additional materials or under reporting of asbestos materials that exist below other floor coverings.
• This report is not represented as, nor is it intended to be, an asbestos abatement scope of work or project specification.
• If suspect materials are discovered during future demolition operations, cease all general work activities which could impact the
Nellis Air Force Base – Bldg. 601 Page 6 discovered suspect materials, until confirmation sampling can be conducted.
Thank you for allowing Macrotec Consulting to assist you with your environmental consulting needs. Please contact me with any questions regarding this report at (702) 338-8213.
Appendix A
Appendix A - Asbestos Assessment
Macrotec Job #12522 - Bldg. 601 ; WO #18503
The following table lists each of the materials suspected to contain asbestos at the subject site. For each material the sample number, location and laboratory result are listed. If the material was found to contain asbestos, the friablity and NESHAP classification is identified.
1 Spray Texture on Walls This material is on the walls in most of the rooms in the subject site.
No Asbestos Detected
AB1 Interior - Rm 20 - S wall None Detected
AB2 Interior - Rm 16 - W wall None Detected
AB3 Interior - Rm 14 - N wall None Detected
AB4 Interior - Rm 8RR - Center None Detected
AB5 Interior - Rm 12 - E wall None Detected
AB6 Interior - Rm 3 - S wall None Detected
AB7 Interior - Rm 5 - E wall None Detected
2 Yellow Sheet Flooring This material is on several floors within the subject site.
No Asbestos Detected
AB8 Interior - Rm 19Closet - Adj. door None Detected
3 Yellow Floor Mastic This material is on several floors within the subject site.
No Asbestos Detected
AB9 Interior - Rm 19Closet - Adj. door None Detected
4 Black Floor Mastic This material is on several floors within the subject site.
No Asbestos Detected
AB10 Interior - Rm 19Closet - Adj. door None Detected
5 Blue Sheet Flooring This material is on several floors within the subject site.
No Asbestos Detected
AB11 Interior - Rm 18RR - Adj. door None Detected
6 Black Floor Mastic This material is on several floors within the subject site.
No Asbestos Detected
AB12 Interior - Rm 18RR - Adj. door None Detected
Asbestos Survey
Bldg. 601
Macrotec Job #12522
Macrotec Job #12522 - Bldg. 601 ; WO #18503
7 Pink/Blue Sheet Flooring This material is on several floors within the subject site.
No Asbestos Detected
AB13 Interior - Rm 22 - S side None Detected
8 Gray Sheet Flooring This material is on several floors within the subject site.
No Asbestos Detected
AB14 Interior - Rm 5Closet - Adj. door None Detected
9 Gray 12x12 Floor Tile This material is on the floor of the closets in rooms 5 and 6.
No Asbestos Detected
AB15 Interior - Rm 5RR - Adj. door None Detected
10 Black Floor Mastic This material is on several floors within the subject site.
No Asbestos Detected
AB16 Interior - Rm 6 - NE corner None Detected
11 2x2 Ceiling Tile This material is on the hall ceilings in the subject site.
No Asbestos Detected
AB17 Interior - Lobby - Center None Detected
12 2x4 Ceiling Tile This material is in the rooms in the subject site.
No Asbestos Detected
AB18 Interior - Rm 19 - Center None Detected
13 Duct Tape & Mud This material is on the ducts above the ceilings.
No Asbestos Detected
AB19 Interior - Lobby - Center None Detected
14 Red Grout This material is on the floor in room 15.
No Asbestos Detected
AB20 Interior - Rm 15 - Adj. hall door None Detected
Asbestos Survey
Bldg. 601
15 Mortar This material is on the exterior walls.
No Asbestos Detected
AB21 Exterior - S Side - Adj. main entry None Detected
16 Brick This material is on the exterior walls.
No Asbestos Detected
AB22 Exterior - S Side - Adj. main entry None Detected
17 Yellow Mastic Behind Ceramic Tile This material is behind ceramic tiles.
No Asbestos Detected
AB23 Interior - Rm 3RR - Adj. door None Detected
18 Yellow Carpet Mastic This material is beneath the carpet throughout the subject site.
No Asbestos Detected
AB24 Interior - N/S Hall - Adj. Rm 8 None Detected
19 Beige Base Cove Mastic This material is behind rubber base cove.
No Asbestos Detected
AB25 Interior - Rm 6 - N side None Detected
20 Window Putty This material is on the windows throughout the subject site.
No Asbestos Detected
AB26 Interior - Rm 3 - S side None Detected
21 Trowel Texture on Ext. Ceilings This material is on the three exterior ceilings.
No Asbestos Detected
AB27 Exterior - Adj. door to lobby None Detected
AB28 Exterior - Adj. door to room 12 None Detected
AB29 Exterior - Adj. door to room 8 None Detected
22 White Roof Mastic This material is on the seams and penetrations throughout the roof.
No Asbestos Detected
AB30 Exterior - Roof - SW corner None Detected
Asbestos Survey
Bldg. 601
23 Black Roof Mastic This material is on various penetrations beneath the white mastic on the roof.
No Asbestos Detected
AB31 Exterior - Roof - SW corner None Detected
24 Black Roof Mastic This material is on various penetrations beneath the white mastic on the roof.
No Asbestos Detected
AB32 Exterior - Roof - NW corner None Detected
25 Gray Roof Mastic This material is on various penetrations beneath the white mastic on the roof.
No Asbestos Detected
AB33 Exterior - Roof - NW corner None Detected
26 Pipe Wrap Cap This material is in the mech room.
No Asbestos Detected
AB34 Interior - Mech Rm - S end None Detected
27 Pipe Wrap This material is in the mech room.
No Asbestos Detected
AB35 Interior - Mech Rm - N end None Detected
28 Smooth Sheet Rock Mud & Tape This material is in the mech room.
No Asbestos Detected
AB36 Interior - Mech Rm - NE corner None Detected
Asbestos Survey
Bldg. 601
Appendix B
Appendix B - Lead Assessment
Macrotec Job #12522 - Bldg. 601 ; WO #18503
The following table lists each of the painted surfaces suspected to contain lead at the subject site. For each painted surface, the sample number, location and laboratory result are listed.
Sample
Painted Surface Description
Sample Location Description
Lab Result (Parts per Million)
L1 Interior - E/W Hall - E end 34Brown Metal Door
L2 Interior - Rm 5 - E wall Below Reportable LimitLt. Pink Sheet Rock Wall
L3 Interior - Rm 5RR - N wall 38Blue Sheet Rock Wall
L4 Interior - Rm 5 - W doorway Below Reportable LimitPink Wood Door Frame
L5 Interior - Rm 5 - N side 85Pink Metal Window Frame
L6 Interior - Rm 4 - S doorway Below Reportable LimitBrown Metal Door Frame
L7 Interior - Rm 4RR - Adj. door Below Reportable LimitOff-white 4x4 Ceramic Wall Tile
L8 Interior - Rm 3RR - Adj. door Below Reportable LimitBrown 1x3 Ceramic Wall Tile
L9 Interior - Rm 3 - N side 45Brown Metal Window Frame
L10 Interior - Rm 2 - N wall Below Reportable LimitBlue Sheet Rock Wall
L11 Interior - Rm 7 - N wall Below Reportable LimitLt. Pink Sheet Rock Wall
L12 Interior - Rm 7 - W ext. door 53Brown Metal Door Frame
L13 Interior - Rm 7RR - Center 33White Sheet Rock Ceiling
L14 Interior - Rm 22 - S side Below Reportable LimitBrown Metal Door
L15 Interior - Rm 20 - Doorway 179Brown Metal Door Frame
L16 Interior - Rm 19Closet - Adj. door Below Reportable LimitWhite Sheet Rock Wall
L17 Interior - Rm 16 - N side 143Pink Metal Window Frame
L18 Interior - Rm 16 - E side 139Pink Metal Door Frame
Lead Paint Survey
Bldg. 601
Appendix B
Sample
Painted Surface Description
Sample Location Description
Lab Result (Parts per Million)
L19 Interior - N/S Hall - Adj. Rm 8 Below Reportable LimitBeige Metal Fire Ext. Box
L20 Interior - Rm 15 Storage - S wall 31Beige Sheet Rock Wall
L21 Interior - Rm 15 - N wall Below Reportable Limit4x4 Beige Ceramic Wall Tile
L22 Interior - Rm 15 - N side Below Reportable Limit6x6 Red Ceramic Floor Tile
L23 Interior - Rm 15 - Adj. E door Below Reportable LimitBeige Metal Electric Box
L24 Interior - Rm 15 - W ext. doorway 465Brown Metal Door Frame
L25 Interior - Rm 15 - W ext. doorway 34Brown Metal Door
L26 Interior - Rm 9RR - NW corner Below Reportable LimitPurple 4x4 Ceramic Wall Tile
L27 Interior - Rm 9 - S wall Below Reportable LimitLt. Pink Sheet Rock Wall
L28 Interior - Rm 14RR - SE corner 25Green 4x4 Ceramic Wall Tile
L29 Interior - Rm 10 - S wall 32Blue Sheet Rock Wall
L30 Interior - Rm 12 - N wall Below Reportable LimitLt. Pink Sheet Rock Wall
L31 Interior - Rm 12 - E side 93Brown Metal Window Frame
L32 Interior - Rm 13 - Doorway to hall 201Brown Metal Door Frame
L33 Interior - Rm 13 - W wall Below Reportable LimitLt. Pink Sheet Rock Wall
L34 Interior - Rm 16 - N wall Below Reportable LimitWhite Sheet Rock Wall
L35 Exterior - Adj. door to rm 8 42Beige Exterior Sheet Rock Ceiling
L36 Exterior - Roof - SW corner 174Beige Metal Roof
L37 Exterior - Roof - NW corner Below Reportable LimitBeige Metal Vent
L38 Interior - Mech Rm - N wall 51White Sheet Rock Wall
L39 Interior - Mech Rm - SW corner 55,754Red Metal Pump
L40 Interior - Mech Rm - W wall 633Red Metal Column
Lead Paint Survey
Bldg. 601
Appendix C
Rm 3
Rm 4 Rm 5
Rm 6
Rm 7
Rm 8Rm 9
Rm 11Rm 12
Rm 13
Rm 14
Rm 15
Rm 16
Rm 19
Rm 20
Rm 22
RR
Mech
RR
RR
RR
Clos
RR
Clos
N/S Hall
Clos Clos
Clos
RR
Stor
Clos
Clos
Clos
Clos
RR
RR Clos
Clos
Clos
RR
RR
RR
E /W
H al l
Asbestos Survey
Bldg. 601
Macrotec Project # 12522
Appendix C
* Diagram Not Drawn To Scale
Sample Location Diagram
N
AB1AB2AB3
AB4
AB5
AB6AB7
AB8AB9AB10AB18AB11AB12
AB13AB14AB15AB16
AB20
AB26AB23AB25AB24 AB17AB19 AB29AB28
AB27AB34AB35 AB36
Appendix C.1
Rm 3
Rm 4 Rm 5
Rm 6
Rm 7
Rm 8Rm 9
Rm 11Rm 12
Rm 13
Rm 14
Rm 15
Rm 16
Rm 19
Rm 20
Rm 22
RR
Mech
RR
RR
RR
Clos
RR
Clos
N/S Hall
Clos Clos
Clos
RR
Stor
Clos
Clos
Clos
Clos
RR
RR Clos
Clos
Clos
RR
RR
RR
E /W
H al l
Lead Based Paint Survey
Bldg. 601
Macrotec Project # 12522
Appendix C
* Diagram Not Drawn To Scale
Sample Location Diagram
N
L1L2L3 L4L5 L6L7 L8L9 L10L13L11L12
L14L16 L15L17 L18L19L20L21 L22 L23L24 L25 L38 L39L40L28
L35L26L27L29L30 L31
L32L33 L34
Appendix D
Macrotec Consulting
TRIANGLE ENVIRONMENTAL SERVICE CENTER, INC.
13509 East Boundary Road, Suite B, Midlothian, VA 23112
804-739-1751 • fax: 804-739-1753
BULK ASBESTOS SAMPLE ANALYSIS SUMMARY
9724 Mild Weather Ct.
Las Vegas, NV 89148
12522
Bldg 601
120206I
2/6/2012
2/7/2012
2/7/2012
F. JiangJOB SITE:
TESC LOGIN #:
DATE OF RECEIPT:
DATE OF ANALYSIS:
DATE OF REPORT:
ANALYST:
TESC
SAMPLE #
CLIENT SAMPLE ID
& GROSS DESCRIPTION
ESTIMATED
% ASBESTOS
NON ASBESTOS
% FIBERS
NON FIBROUS
% MATERIALS
CLIENT:
CLIENT JOB/ #:
1 AB1 / White powder NAD 100%
2 AB2 / White powder NAD 100%
3 AB3 / White powder NAD 100%
4 AB4 / White powder NAD 100%
5 AB5 / White powder NAD 100%
6 AB6 / White powder NAD 100%
7 AB7 / White powder NAD 100%
8 AB8 / Yellow lino., gray fibers NAD 75%20% Cellulose
5% Synthetic
9 AB9 / Yellow adhesive NAD 100%
10 AB10 / Black adhesive NAD 100%
Tuesday, February 07, 2012 Page 1 of 4
Samples are analyzed in accordance with “Interim Method for the Determination of Asbestos in Bulk Insulation Samples”, EPA/600/R-93-116, July 1993
(EPA-600/M4-82-020, Dec 1982), or the current US EPA method for the analysis of asbestos in building material. None Detected: not detected at/or below the detected limit of method (Reporting limit: 1% Asbestos). Glass fiber is analyzed for quality control blank. TESC recommends by point count or
Transmission Electron Microscopy (TEM), for materials regulated by the EPA NESHAP (National Emission Standards for Hazardous Air Pollutants) and found to contain less than ten percent (<10%) asbestos by Polarized Light Microscopy (PLM). Both services are available for an additional fee. This report must not be reproduced except in full with approval of Triangle Environmental Service Center, Inc. This test report relates only to the item(s) tested.
NVLAP Lab Code: 200794-0 LEGEND NAD=No Asbestos Detected, Lino.=Linoleum, JC=Joint Compound] [
Reviewed By Authorized Signatory:
Feng Jiang, MS Senior Geologist, Laboratory Director
Yuedong Fang, Senior Geologist
13509 East Boundary Road, Suite B, Midlothian, VA 23112
12522
Bldg 601
120206I
2/6/2012
2/7/2012
2/7/2012
F. JiangJOB SITE:
TESC LOGIN #:
DATE OF RECEIPT:
DATE OF ANALYSIS:
DATE OF REPORT:
ANALYST:
TESC
SAMPLE #
CLIENT SAMPLE ID
& GROSS DESCRIPTION
ESTIMATED
% ASBESTOS
NON ASBESTOS
% FIBERS
NON FIBROUS
% MATERIALS
CLIENT:
11 AB11 / Blue vinyl NAD 100%
12 AB12 / Black adhesive NAD 100%
13 AB13 / Pink, blue lino. & gray fibers NAD 90%10% Fiberglass
14 AB14 / Gray lino., gray fibers NAD 80%20% Cellulose
15 AB15 / Gray vinyl NAD 100%
16 AB16 / Black adhesive NAD 100%
17 AB17 / Gray fibers NAD 15%80% Cellulose
5% Fiberglass
18 AB18 / Gray fibers NAD 10%80% Cellulose
10% Fiberglass
19 AB19 / White adhesive, white fibers NAD 30%70% Fiberglass
20 AB20 / Red granular NAD 100%
Tuesday, February 07, 2012 Page 2 of 4
Samples are analyzed in accordance with “Interim Method for the Determination of Asbestos in Bulk Insulation Samples”, EPA/600/R-93-116, July 1993
(EPA-600/M4-82-020, Dec 1982), or the current US EPA method for the analysis of asbestos in building material. None Detected: not detected at/or below the detected limit of method (Reporting limit: 1% Asbestos). Glass fiber is analyzed for quality control blank. TESC recommends by point count or
Transmission Electron Microscopy (TEM), for materials regulated by the EPA NESHAP (National Emission Standards for Hazardous Air Pollutants) and found to contain less than ten percent (<10%) asbestos by Polarized Light Microscopy (PLM). Both services are available for an additional fee. This report must not be reproduced except in full with approval of Triangle Environmental Service Center, Inc. This test report relates only to the item(s) tested.
NVLAP Lab Code: 200794-0 LEGEND NAD=No Asbestos Detected, Lino.=Linoleum, JC=Joint Compound] [
Reviewed By Authorized Signatory:
13509 East Boundary Road, Suite B, Midlothian, VA 23112
12522
Bldg 601
120206I
2/6/2012
2/7/2012
2/7/2012
F. JiangJOB SITE:
TESC LOGIN #:
DATE OF RECEIPT:
DATE OF ANALYSIS:
DATE OF REPORT:
ANALYST:
TESC
SAMPLE #
CLIENT SAMPLE ID
& GROSS DESCRIPTION
ESTIMATED
% ASBESTOS
NON ASBESTOS
% FIBERS
NON FIBROUS
% MATERIALS
CLIENT:
21 AB21 / Gray ganular NAD 100%
22 AB22 / Gray ganular NAD 100%
23 AB23 / Yellow adhesive NAD 100%
24 AB24 / Yellow adhesive NAD 100%
25 AB25 / Yellow adhesive NAD 100%
26 AB26 / Black rubber NAD 100%
27 AB27 / White powder NAD 100%
28 AB28 / White powder NAD 100%
29 AB29 / White powder NAD 100%
30 AB30 / White adhesive NAD 100%
Tuesday, February 07, 2012 Page 3 of 4
Samples are analyzed in accordance with “Interim Method for the Determination of Asbestos in Bulk Insulation Samples”, EPA/600/R-93-116, July 1993
(EPA-600/M4-82-020, Dec 1982), or the current US EPA method for the analysis of asbestos in building material. None Detected: not detected at/or below the detected limit of method (Reporting limit: 1% Asbestos). Glass fiber is analyzed for quality control blank. TESC recommends by point count or
Transmission Electron Microscopy (TEM), for materials regulated by the EPA NESHAP (National Emission Standards for Hazardous Air Pollutants) and found to contain less than ten percent (<10%) asbestos by Polarized Light Microscopy (PLM). Both services are available for an additional fee. This report must not be reproduced except in full with approval of Triangle Environmental Service Center, Inc. This test report relates only to the item(s) tested.
NVLAP Lab Code: 200794-0 LEGEND NAD=No Asbestos Detected, Lino.=Linoleum, JC=Joint Compound] [
Reviewed By Authorized Signatory:
13509 East Boundary Road, Suite B, Midlothian, VA 23112
12522
Bldg 601
120206I
2/6/2012
2/7/2012
2/7/2012
F. JiangJOB SITE:
TESC LOGIN #:
DATE OF RECEIPT:
DATE OF ANALYSIS:
DATE OF REPORT:
ANALYST:
TESC
SAMPLE #
CLIENT SAMPLE ID
& GROSS DESCRIPTION
ESTIMATED
% ASBESTOS
NON ASBESTOS
% FIBERS
NON FIBROUS
% MATERIALS
CLIENT:
31 AB31 / Black adhesive NAD 90%10% Cellulose
32 AB32 / Black adhesive NAD 90%10% Cellulose
33 AB33 / Gray adhesive NAD 90%10% Cellulose
Total Samples/Layers Analyzed: 33
Tuesday, February 07, 2012 Page 4 of 4
Samples are analyzed in accordance with “Interim Method for the Determination of Asbestos in Bulk Insulation Samples”, EPA/600/R-93-116, July 1993
(EPA-600/M4-82-020, Dec 1982), or the current US EPA method for the analysis of asbestos in building material. None Detected: not detected at/or below the detected limit of method (Reporting limit: 1% Asbestos). Glass fiber is analyzed for quality control blank. TESC recommends by point count or
Transmission Electron Microscopy (TEM), for materials regulated by the EPA NESHAP (National Emission Standards for Hazardous Air Pollutants) and found to contain less than ten percent (<10%) asbestos by Polarized Light Microscopy (PLM). Both services are available for an additional fee. This report must not be reproduced except in full with approval of Triangle Environmental Service Center, Inc. This test report relates only to the item(s) tested.
NVLAP Lab Code: 200794-0 LEGEND NAD=No Asbestos Detected, Lino.=Linoleum, JC=Joint Compound] [
Reviewed By Authorized Signatory:
13509 East Boundary Road, Suite B, Midlothian, VA 23112
12522
Bldg 601
120208H
2/8/2012
2/9/2012
2/9/2012
F. JiangJOB SITE:
TESC LOGIN #:
DATE OF RECEIPT:
DATE OF ANALYSIS:
DATE OF REPORT:
ANALYST:
TESC
SAMPLE #
CLIENT SAMPLE ID
& GROSS DESCRIPTION
ESTIMATED
% ASBESTOS
NON ASBESTOS
% FIBERS
NON FIBROUS
% MATERIALS
CLIENT:
1 AB1 / Gray fibers NAD 5%95% Fiberglass
2 AB2 / Brown, white fibers NAD 2%98% Cellulose
3 AB3 / White powder, brown fibers NAD 80%20% Cellulose
Total Samples/Layers Analyzed: 3
Thursday, February 09, 2012 Page 1 of 1
Samples are analyzed in accordance with “Interim Method for the Determination of Asbestos in Bulk Insulation Samples”, EPA/600/R-93-116, July 1993
(EPA-600/M4-82-020, Dec 1982), or the current US EPA method for the analysis of asbestos in building material. None Detected: not detected at/or below the detected limit of method (Reporting limit: 1% Asbestos). Glass fiber is analyzed for quality control blank. TESC recommends by point count or
Transmission Electron Microscopy (TEM), for materials regulated by the EPA NESHAP (National Emission Standards for Hazardous Air Pollutants) and found to contain less than ten percent (<10%) asbestos by Polarized Light Microscopy (PLM). Both services are available for an additional fee. This report must not be reproduced except in full with approval of Triangle Environmental Service Center, Inc. This test report relates only to the item(s) tested.
NVLAP Lab Code: 200794-0 LEGEND NAD=No Asbestos Detected, Lino.=Linoleum, JC=Joint Compound] [
Reviewed By Authorized Signatory:
Appendix D.1
13509 East Boundary Road, Suite B, Midlothian, VA 23112 • 804-739-1751 • fax: 804-739-1753
(EPA METHOD 7420)
LEAD IN PAINT SAMPLE ANALYSIS SUMMARY
9724 Mild Weather Ct.
Las Vegas, NV 89148
12522
Bldg 601
120206J
2/6/2012
2/7/2012
2/8/2012
S. Al-JohaniJOBSITE:
TESC LOGIN #:
DATE OF RECEIPT:
DATE OF ANALYSIS:
DATE OF REPORT:
ANALYST:
TESC
SAMPLE #
CLIENT
SAMPLE
WEIGHT (mg)
LEAD CONCENTRATION
PPM
CLIENT:
CLIENT JOB #:
LEAD CONCENTRATION
(% by Weight)
TOTAL LEAD
(ug)
1 L1 318 0.003 3410.8
2 L2 335 < 0.003 < 30< 10.0
3 L3 337 0.004 3812.7
4 L4 305 < 0.003 < 33< 10.0
5 L5 369 0.009 8531.4
6 L6 336 < 0.003 < 30< 10.0
7 L7 552 < 0.002 < 18< 10.0
8 L8 523 < 0.002 < 19< 10.0
9 L9 322 0.005 4514.6
10 L10 318 < 0.003 < 31< 10.0
Wednesday, February 08, 2012 Page 1 of 4
Reviewed By Authorized Signatory:
Feng Jiang, MS Senior Geologist, Laboratory Director
Yuedong Fang, Senior Geologist
The condition of the samples analyzed was acceptable upon receipt per laboratory protocol unless otherwise noted on this report. Results represent the analysis of samples submitted by the customer. Sample information was provided by the customer. This report must not be reproduced, except in full,without the written consent of Triangle Environmental Service Center, Inc. The test report related only to the item(s) tested. This analysis was performed by an AHIA accredited laboratory. AIHA/ELLAP ID: 100527, NYELAP/NELAC ID: 11413.
Minimum Reporting Limit: 20 ug. Lead Based Paint contains 0.5% lead by weight per Federal statute. The OSHA Lead in Construction Standard, 29 CFR
1926.62, is invoked if any lead is present in the sample. Lead-free paint is defined as <0.06% by weight (CPSC).
[LEGEND: mg= milligram, ug= microgram, ppm= parts per million]
9724 Mild Weather Ct.
Las Vegas, NV 89148
12522
Bldg 601
120206J
2/6/2012
2/7/2012
2/8/2012
S. Al-JohaniJOBSITE:
TESC LOGIN #:
DATE OF RECEIPT:
DATE OF ANALYSIS:
DATE OF REPORT:
ANALYST:
LEAD CONCENTRATION
PPM
CLIENT:
CLIENT JOB #:
LEAD CONCENTRATION
(% by Weight)
TOTAL LEAD
(ug)
11 L11 323 < 0.003 < 31< 10.0
12 L12 344 0.005 5318.3
13 L13 330 0.003 3310.8
14 L14 297 < 0.003 < 34< 10.0
15 L15 207 0.018 17937.1
16 L16 314 < 0.003 < 32< 10.0
17 L17 260 0.014 14337.1
18 L18 172 0.014 13923.9
19 L19 118 < 0.008 < 85
Sample weight below Lab SOP guidelines.
< 10.0
20 L20 346 0.003 3110.8
Wednesday, February 08, 2012 Page 2 of 4
Reviewed By Authorized Signatory:
Feng Jiang, MS Senior Geologist, Laboratory Director
Yuedong Fang, Senior Geologist
The condition of the samples analyzed was acceptable upon receipt per laboratory protocol unless otherwise noted on this report. Results represent the analysis of samples submitted by the customer. Sample information was provided by the customer. This report must not be reproduced, except in full,without the written consent of Triangle Environmental Service Center, Inc. The test report related only to the item(s) tested. This analysis was performed by an AHIA accredited laboratory. AIHA/ELLAP ID: 100527, NYELAP/NELAC ID: 11413.
Minimum Reporting Limit: 20 ug. Lead Based Paint contains 0.5% lead by weight per Federal statute. The OSHA Lead in Construction Standard, 29 CFR
1926.62, is invoked if any lead is present in the sample. Lead-free paint is defined as <0.06% by weight (CPSC).
9724 Mild Weather Ct.
Las Vegas, NV 89148
12522
Bldg 601
120206J
2/6/2012
2/7/2012
2/8/2012
S. Al-JohaniJOBSITE:
TESC LOGIN #:
DATE OF RECEIPT:
DATE OF ANALYSIS:
DATE OF REPORT:
ANALYST:
LEAD CONCENTRATION
PPM
CLIENT:
CLIENT JOB #:
LEAD CONCENTRATION
(% by Weight)
TOTAL LEAD
(ug)
21 L21 559 < 0.002 < 18< 10.0
22 L22 550 < 0.002 < 18< 10.0
23 L23 151 < 0.007 < 66
Sample weight below Lab SOP guidelines.
< 10.0
24 L24 233 0.047 465108.4
25 L25 318 0.003 3410.8
26 L26 225 < 0.004 < 44< 10.0
27 L27 327 < 0.003 < 31< 10.0
28 L28 512 0.002 2512.7
29 L29 337 0.003 3210.8
30 L30 328 < 0.003 < 30< 10.0
Wednesday, February 08, 2012 Page 3 of 4
Reviewed By Authorized Signatory:
Feng Jiang, MS Senior Geologist, Laboratory Director
Yuedong Fang, Senior Geologist
The condition of the samples analyzed was acceptable upon receipt per laboratory protocol unless otherwise noted on this report. Results represent the analysis of samples submitted by the customer. Sample information was provided by the customer. This report must not be reproduced, except in full,without the written consent of Triangle Environmental Service Center, Inc. The test report related only to the item(s) tested. This analysis was performed by an AHIA accredited laboratory. AIHA/ELLAP ID: 100527, NYELAP/NELAC ID: 11413.
Minimum Reporting Limit: 20 ug. Lead Based Paint contains 0.5% lead by weight per Federal statute. The OSHA Lead in Construction Standard, 29 CFR
1926.62, is invoked if any lead is present in the sample. Lead-free paint is defined as <0.06% by weight (CPSC).
9724 Mild Weather Ct.
Las Vegas, NV 89148
12522
Bldg 601
120206J
2/6/2012
2/7/2012
2/8/2012
S. Al-JohaniJOBSITE:
TESC LOGIN #:
DATE OF RECEIPT:
DATE OF ANALYSIS:
DATE OF REPORT:
ANALYST:
LEAD CONCENTRATION
PPM
CLIENT:
CLIENT JOB #:
LEAD CONCENTRATION
(% by Weight)
TOTAL LEAD
(ug)
31 L31 277 0.009 9325.8
32 L32 287 0.020 20125.7
33 L33 319 < 0.003 < 31< 10.0
34 L34 331 < 0.003 < 30< 10.0
35 L35 349 0.004 4214.6
36 L36 191 0.017 174
Sample weight below Lab SOP guidelines.
33.3
37 L377 317 < 0.003 < 32< 10.0
Total Sample(s) Analyzed:
Wednesday, February 08, 2012 Page 4 of 4
Reviewed By Authorized Signatory:
Feng Jiang, MS Senior Geologist, Laboratory Director
Yuedong Fang, Senior Geologist
The condition of the samples analyzed was acceptable upon receipt per laboratory protocol unless otherwise noted on this report. Results represent the analysis of samples submitted by the customer. Sample information was provided by the customer. This report must not be reproduced, except in full,without the written consent of Triangle Environmental Service Center, Inc. The test report related only to the item(s) tested. This analysis was performed by an AHIA accredited laboratory. AIHA/ELLAP ID: 100527, NYELAP/NELAC ID: 11413.
Minimum Reporting Limit: 20 ug. Lead Based Paint contains 0.5% lead by weight per Federal statute. The OSHA Lead in Construction Standard, 29 CFR
1926.62, is invoked if any lead is present in the sample. Lead-free paint is defined as <0.06% by weight (CPSC).
9724 Mild Weather Ct.
Las Vegas, NV 89148
12522
Bldg 601
120208J
2/8/2012
2/9/2012
2/10/2012
O. ElshowayaJOBSITE:
TESC LOGIN #:
DATE OF RECEIPT:
DATE OF ANALYSIS:
DATE OF REPORT:
ANALYST:
LEAD CONCENTRATION
PPM
CLIENT:
CLIENT JOB #:
LEAD CONCENTRATION
(% by Weight)
TOTAL LEAD
(ug)
1 L38 315 0.005 5116.1
2 L39 320 5.575 55,75417,841.4
3 L40 212 0.063 633134.1
Total Sample(s) Analyzed:
Friday, February 10, 2012 Page 1 of 1
Reviewed By Authorized Signatory:
Feng Jiang, MS Senior Geologist, Laboratory Director
Yuedong Fang, Senior Geologist
The condition of the samples analyzed was acceptable upon receipt per laboratory protocol unless otherwise noted on this report. Results represent the analysis of samples submitted by the customer. Sample information was provided by the customer. This report must not be reproduced, except in full,without the written consent of Triangle Environmental Service Center, Inc. The test report related only to the item(s) tested. This analysis was performed by an AHIA accredited laboratory. AIHA/ELLAP ID: 100527, NYELAP/NELAC ID: 11413.
Minimum Reporting Limit: 20 ug. Lead Based Paint contains 0.5% lead by weight per Federal statute. The OSHA Lead in Construction Standard, 29 CFR
1926.62, is invoked if any lead is present in the sample. Lead-free paint is defined as <0.06% by weight (CPSC).
| 12522 - Bldg. 601.pdf |
| Appendix A.pdf |
| 12522 - As Assess.pdf |
| Appendix B.pdf |
| 12522 - Pb Assess.pdf |
| Appendix C.pdf |
| 12522 As Diagram.pdf |
| Appendix C.1.pdf |
| 12522 Pb Diagram.pdf |
| Appendix D.pdf |
| 12522 - As Lab.pdf |
| 120206i |
| CCF00272012_00035 |
| CCF00272012_00036 |
| 12522 - As Lab2.pdf |
| 120208h |
| CCF00292012_00027 |
| Appendix D.1.pdf |
| 12522 - Pb Lab.pdf |
| 120206j |
| CCF00282012_00000 |
| CCF00282012_00001 |
| 12522 - Pb Lab 2.pdf |
| 120208j |
| CCF00292012_00029 |
File details come from the government source that posted it. Updated .