FA485525R0008 - QA 2 - 16 Dec 2024.pdf
PDF 100 KB Posted
- Attached to
- Cannon AFB Microwave System Support Services Federal contract opportunity
- Solicitation number
- FA485525R0008
About this file
This is a Questions and Answers document for solicitation FA485525R0008 for Cannon AFB Microwave System Support Services, dated December 16, 2024. The document clarifies that there are 7 total towers in the system, with heights ranging from 20 feet to 150 feet. Some towers are attached to poles on buildings rather than being free-standing structures. The locations include Building 9 (75ft), RSC B1095 (40ft), B5000 (150ft), Building 2302 (100ft), Building 3161b (100ft), Building 3161a (80ft), and Sundale (20ft).
The document also addresses safety equipment, confirming that all free-standing towers are equipped with safety climb systems. One tower at MAFR (Melrose Air Force Range) is noted to have a different style of safety climb system compared to the others.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| FA485525R0008 - QA - 16 Dec 2024.pdf | ||
| FA485525R0008 - QA - 04 Dec 2024.pdf | ||
| Attachement 1 - Performance Work Statement_Microwave Contract - 02 Dec 2024.pdf | ||
| Addemdum - FA485525R0008.pdf | ||
| Combo - Microwave Support Service - FA485525R0008 - 05Nov24.pdf | ||
| Attachment 2 - Provisions and Clauses.pdf | ||
| Attachment 04 - Price List.xlsx | XLSX spreadsheet | |
| Attachement 1 - Performance Work Statement Microwave MX.pdf | ||
| Attachment 3 - WD 2015 5457 Rev 25.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Cannon AFB Microwave System Support Services
FA485525R0008
16 December 2024
1) Are those the only two towers?
a. There are currently 7 “towers”. (Note: Some are attached to poles attached to buildings)
Location TWR Height (ft)
Bldg 9 75
RSC B1095 40
B5000 150 Bldg 2302 100 Bldg 3161b 100 Bldg 3161a 80 Sundale 20
2) Related… are there safety climbs on all the towers?
a. All free-standing towers are equipped with safety climb systems although from the pictures one of the towers at MAFR is a different style of safety climb.
https://sam.gov/opp/607bd965ef704741a00306ec9b7d49bc/review