3. RFP APPENDIX - B Drawings 13Jun2022.pdf
PDF 5 MB Posted
- Attached to
- Repair/Restore Pest Management Facility Federal contract opportunity
- Solicitation number
- FA481922R0015
About this file
This document provides details for a design-build project to repair and restore a Pest Management Facility at Tyndall Air Force Base in Florida. The project is a firm-fixed price contract with a period of performance of 365 days from the notice to proceed. The requirement is estimated between $800,000 and $2,000,000. The solicitation is set aside for HUBZone small businesses and was issued by the Department of the Air Force Air Combat Command. Performance and payment bonds are required. Davis-Bacon wage determinations for building construction in Florida apply. A site visit will be conducted with the end user, contractor, Civil Engineer, and Construction Squadron as outlined in Section L.
View the file
Other files for this federal contract opportunity
Show all 27
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
APPENDIX – B
CONCEPTUAL DRAWINGS OF NEW BUILDING
AND
AS-BUILT DRAWINGS OF EXISTING BUILDING
For
REQUEST FOR PROPOSAL
Repair (Restore) Pest Management Facility
TYNDALL AFB FLORIDA
FOR PROJECT XLWU 20-8196
A102
EXISTING FENCE
TO BE REMOVED
EXISTING FORCE
MAIN
EXISTING WATER
LINE
A102
NEW FENCE
LOCATION
NEW DRY SWALE
LOCATION
A1023
A102 4
JM
O
N D
O 6/
/2
:4
9:
P M
187 SF
UTILITY
272 SF
BREAK/
CIRCULATION
108 SF
INSECTICIDE
152 SF
INSECTICIDE
168 SF
HERBICIDE
497 SF
OPEN
BREEZEWAY
478 SF
OPEN
DRIVE
A102
60 SF
MECH/ELEC
118'
0"
58 SF
COMM
64 SF
STORAGE
131 SF
EQUIP
REPAIR
8'
0"
8' - 0" 16' - 4"
EXISTING WALL
NEW WALL
DEMOLISHED WALL
WH
ALIGN
FINISHED
FLOORS
FLOOR HEIGHT
TO ALIGN
734 SF
ROOF
COVER
87 SF
STORAGE
523 SF
ROOF
COVER
A102
A1023
A102 4
JM
O
N D
O 6/
/2
:4
8:
P M
1/8" = 1'-0"
FL 1
ROOM AREA SCHEDULE
Area Name Number
187 SF UTILITY 1
272 SF BREAK/ CIRCULATION 2
108 SF INSECTICIDE 5
152 SF INSECTICIDE 6
168 SF HERBICIDE 8
497 SF OPEN BREEZEWAY 9
478 SF OPEN DRIVE 10
60 SF MECH/ELEC 11
58 SF COMM 12
64 SF STORAGE 13
131 SF EQUIP REPAIR 14
734 SF ROOF COVER 15
87 SF STORAGE 17
523 SF ROOF COVER 18
3520 SF
BUILDING FOOT PRINT 2600 SF
FL 1
0' - 0"
TOW
9' - 1"
1 1/2" 1'-0" 1 1/2"
1'-0"
TOR
15' - 7"
DEPTH SURROUND
TYP. ROOFLINE
2' - 0"
DEPTH SURROUND
TYP. ROOFLINE
2' - 0"
OPENOPEN
JM
O
N D
O 6/
/2
:4
9:
P M
1/8" = 1'-0"
ELEVATION 1
1/8" = 1'-0"
ELEVATION 2
1/8" = 1'-0"
ELEVATION 3
3 1/8" = 1'-0"
ELEVATION 4
JM
O
N D
O 6/
/2
:4
9:
P M
**:"n*:
i.r--: - :-*-,-*
-::.4=' q-s-*'--j:.i-}|-_-.
TII:':
"**-1Jj"**" *.-- f i-
.l r
Nores:
i: <!\q<r .gr tau ,o{!- :&!*}<qrar* rs ..*vl
^i i+Lsa
L rSr*rlq a'a'4.r ,q5. 4*:* *.*{ 'c!.c vr r I
-F-GS r '* aa.*qa i L,-;dv6a.q:. {e tq!4a {o ! qr, 9!.' gst + *. 6. Fr eh\q ):
t--t j'
{ ia =qd.j:rn:$.S =a*aBlFr:**
I
*f -;tr.ff-n'-
-*1 t
****{i
, trl *t.{ -
*." **^o";*u,*_, ,J Er.rr (".. '*er{Anrf , , I
'iti i"rt{. I-it tiiI;It4 I -*- --:
-a* r'
€air-. ' - : 'l i.J =*u-r
€ c.$ f- -* rj.f.,i rJal:5lre"ciD'(sc*\\'TroN.
.!ffi - *i!> FA$:Y!3* s.qll nt 3d* ?'a<!, $ - -M ?se@*aft-* riG r+rtEwu( Iaar\ - 6r$sr$ lrrcia!d/a!5 $( tA(sg*gE \P?l() $ LOOV CR
,--- "t , oc*s(rl te#{4c= I
.iet!Fa'{( x"l Batr ffi
-1---T-:-r--l rl :-l
L& l-rtt-1-]-ffi ---1-1--1-t- H-H_ aao-l rl {l il !l
\l
| Combined Drawings.pdf |
| Presentation.pdf |
| Slide Number 1 |
| Slide Number 2 |
| Slide Number 3 |
| Slide Number 4 |
| Slide Number 5 |
| Concept of New Work.pdf |
| Pest Control - Sheet - A101 - 2022_0511 |
| Sheets |
| A101 - Unnamed |
| A103 - Unnamed |
| A104 - Unnamed |
| Pest Control - Sheet - A103 - 2022_0511 |
| Sheets |
| A101 - Unnamed |
| A103 - Unnamed |
| A104 - Unnamed |
| Pest Control - Sheet - A104 - 2022_0511 |
| Sheets |
| A101 - Unnamed |
| A103 - Unnamed |
| A104 - Unnamed |
| Site Plan Overhead.pdf |
| Sheets |
| A101 - Unnamed |
| A102 - Unnamed |
| A103 - Unnamed |
| A104 - Unnamed |
| Building Floor Plan.pdf |
| Sheets |
| A101 - Unnamed |
| A102 - Unnamed |
| A103 - Unnamed |
| A104 - Unnamed |
| Site Plan Overhead Projection.pdf |
| Sheets |
| A101 - Unnamed |
| A102 - Unnamed |
| A103 - Unnamed |
| A104 - Unnamed |
| Elevation Views.pdf |
| Sheets |
| A101 - Unnamed |
| A102 - Unnamed |
| A103 - Unnamed |
| A104 - Unnamed |
File details come from the government source that posted it. Updated .