This document contains an attachment to a solicitation for repair work at Tyndall Air Force Base in Florida. The solicitation seeks proposals to modify an existing building to accommodate the installation of eight motorized coiling doors, relocate light switches, demolish existing bollards and install new protective bollards, and modify the building to add a 10'x10' mechanical room. A site visit will be held on August 3, 2021. Offerors are encouraged to thoroughly review the solicitation and its attachments. The 325th Contracting Squadron at Tyndall AFB is issuing the solicitation on behalf of the Department of the Air Force Air Combat Command.
View the file
Other files for this federal contract opportunity
Show all 35
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1 1 1 1 1 1 1 1
2 2
3 3 3 3 3 3 3 3 3
4 4 4 4 4 4 4 4
NOTES:
1 MODIFY THE EXISTING PANELING ON THE BUILDING TO RECEIVE
NEW STRUCTURAL STEEL FOR THE INSTALLATION OF (8EA)
MOTORIZED COILING DOORS TO INCLUDE REQUIRED CIRCUITRY.
NEW METAL WALL PANELING, FLASHING & GUTTERS TO BE SIMILAR
TO THE REST OF THE BUILDING.
2 RELOCATE THE EXISTING LIGHT SWITCHES TO ACCOMMODATE THE
(2EA) PERSONNEL DOORS INSTALLED AT EACH END OF THE BUILDING.
3 DEMO THE EXISTING BOLLARDS. BOLLARD SHALL BE CUT OFF FLUSH
WITH THE EXISTING GRADE.
4 INSTALL NEW 6’ BOLLARDS TO PROTECT THE COILING DOORS. BOLLARD
SHALL HAVE A 3’ EMBEDMENT & EXTEND 4’ ABOVE GRADE. BOLLARD
SHALL BE CONCRETE FILLED & PAINTED YELLOW.
5 CONTRACTOR SHALL MODIFY THE BUILDING FOR THE ADDITION OF A
10’X10’ MECHANICAL ROOM TO HOUSE THE NEW FA/ SUPPRESSION SYSTEM.
TYNDALL A.F.B., FL. 32403
325th CIVIL ENGINEERING SQUADRON
Task Order No.
SHEET:
PROJ. NO.
SCALE:
DATE:
Sheet Title
DRAWN BY:
DESIGNED BY:
TYNDALL A.F.B., FL. 32403
A-1 521/8" = 1' - 0"A. BOLING
FLOOR PLAN
BLDG #1142
ROLL-UP DOORS
CONSTRUCT
B. ROCHA 15 SEPT 16 16-1007
FLOOR PLAN
SCALE: 1/8"=1'-0"
NOT FOR CONSTRUCTION
AutoCAD SHX Text
OF
AutoCAD SHX Text
NO.
AutoCAD SHX Text M
AutoCAD SHX Text T
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text O
AutoCAD SHX Text M
AutoCAD SHX Text A
AutoCAD SHX Text R
AutoCAD SHX Text C
AutoCAD SHX Text I
AutoCAD SHX Text M
AutoCAD SHX Text O
AutoCAD SHX Text A
AutoCAD SHX Text N
AutoCAD SHX Text D
AutoCAD SHX Text
REVISION
AutoCAD SHX Text
DATE
AutoCAD SHX Text
BY
AutoCAD SHX Text
SHT. REF. NO.
File details come from the government source that posted it. Updated .