4. Attachment 4. Questions Document.docx
DOCX document 29 KB Posted
- Attached to
- Refrigerant Recovery System Federal contract opportunity
- Solicitation number
- FA466124Q0099
About this file
This document is a Questions and Answers document related to Solicitation Number FA466124Q0099 for a Refrigerant Recovery System. The key details are:
The solicitation is for the provision of a high efficiency recovery storage system for high pressure refrigerants used to maintain aerospace ground equipment at Dyess Air Force Base. The contractor must provide one Lite Evac/ASME Packaged Recycle/Recovery Unit capable of recovering RSS, R134a, R407 and other high pressure refrigerants. The system must include a 120 gallon ASME tank, ASME tools, and mini purge units, meeting the salient characteristics listed in Attachment 1.
The questions address acceptable power configurations (1-phase, 2-phase or 3-phase) and horsepower (2 HP or 3 HP), confirm that only delivery is required with no installation, and provide the full shipping address of 925 Ave E-1 Bldg 5204, Dyess AFB, TX 79607. The solicitation is being issued by the Department of the Air Force Global Strike Command.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 4. Attachment 1 - Salient Characteristics.docx | DOCX document | |
| 4. 1. COMBO Refrigerant Recovery System (Amend 3).docx | DOCX document | |
| 3. Attachment 4. Questions Document.docx | DOCX document | |
| 3. 1. COMBO Refrigerant Recovery System (Amend 2).rtf | RTF text file | |
| 3. Attachment 1 - Salient Characteristics.docx | DOCX document | |
| COMBO Refrigerant Recovery System (Mod 1).rtf | RTF text file | |
| COMBO Refrigerant Recovery System.rtf | RTF text file | |
| Attachment 3 - FA466124Q0099 FAR 52.212-5.docx | DOCX document | |
| Attachment 2 - FA466124Q0099 FAR Provisions and Clauses.docx | DOCX document | |
| Attachment 1 - Salient Characteristics.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
24 July 24
Questions for FA4661 24-Q-0099 Refrigerant Recovery
1. Specs are calling for a 3PH where the unit only comes in 1PH, and the unit is 2 HP (UPDATED)
0. 1 Ph, 2 Ph, or 3 Ph is acceptable. Please make sure to specify.
0. 2 HP and 3 HP are acceptable
1. Can you please confirm that only delivery is needed, and no installation will be required?
1. No installation is needed
1. Can you please provide the full shipping address?
925 Ave E-1 Bldg 5204 Dyess AFB, TX. 79607