4. Attachment 1 - Salient Characteristics.docx

DOCX document 41 KB Posted

Attached to
Refrigerant Recovery System
Solicitation number
FA466124Q0099
Issued by

About this file

This document contains the salient characteristics specification for a refrigerant reclaimer and related equipment required under a federal contract opportunity.

The specification outlines the requirements for one high capacity 1200 cfm air cooled refrigerant recovery/recycle/reclaim unit compatible with R134a, R410A and other high pressure refrigerants. The unit must include a minimum 120-gallon tank, tools, and a mini purge unit, all meeting ASME standards. The performance may exceed the minimum requirements. The solicitation also requires a tank scale and a portable refrigerant purge unit. The federal contract opportunity is for the Department of the Air Force Global Strike Command to procure this equipment to support aircraft maintenance at Dyess AFB.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Specifications for refrigerant reclaimer and related equipment.

1. The Contractor shall provide one (1 each) Recovery/Recycle/Reclaim high pressure refrigerant unit for the recovery, compatible with R134a, R410A and other High Pressure Refrigerants. System must include a min 120 gallon tank, tools, and mini purge unit. All the following items must meet American Society of Mechanics (ASME) standard regulation requirements. Performance may exceed any minimum requirement.

ITEM

NUMBER

Description
QUANTITY
UNIT
0001
High capacity 1200 cfm air cooled condenser w/attachments

Recycle/recovery unit 230V/60HZ/1Ph, 2Ph, or 3Ph/2 HP or 3 HP with a minimum 120 gallon tank, To include the following Min /max specifications:

Push/Pull Rates (R22) 81-lbs/min Vapor Rates (R22) 2.14-lbs/min Float Connection 3-pin BH Connections 1/2” flare Low Pressure Switch 15” Hg Liquid and Vapor ports: 1/2” threaded connect

Quantity for Tool/Attachments QTY 2 – 48 cubic inch drier core QTY 1 – 80% Tank Float Cable QTY 1 – 10 ft. 1/2” hose with isolation valves QTY 2 – 20 ft. 1/2” hoses with isolation valves QTY 1 – 50’ power cable QTY 2 – 1/2 to 5/8 adapters QTY 2 – 5/8 to 3/4 Adapters

1
EA
0002
Tank Scale

For use with all the 120, 250 and 500 Gallon Must be attached in line to the tank (not a separate unit)

1
EA
0003
Portable Refrigerant Purge Unit

Discharge efficiency within +/- .02 of 0.08 lb-refg/lb non-condensibles

1
EA

16 Jul 24 Last Updated

File details come from the government source that posted it. Updated .