Addendum for Dog Kennel Amendment 0003.docx

DOCX document 11 KB Posted

Attached to
Replace Military Working Dog Kennel Federal contract opportunity
Solicitation number
FA4626-11-R-0003
Issued by
Department of the Air Force Global Strike Command

About this file

Addendum for Amendment

View the file

Other files for this federal contract opportunity

Other files attached to Replace Military Working Dog Kennel, newest first.
File Type Posted
Amendment 0003 Question and Answers.docx DOCX document
Bid Schedule.docx DOCX document
Drawings.pdf PDF
Amendment 003.doc DOC document
Questions and Answers.docx DOCX document
Bore Logs.docx DOCX document
Kennel Bore Logs.pdf PDF
Federal Government Shut Down.docx DOCX document
Dog Kennel Pre-Proposal.pptx PPTX presentation
Site Visit Attendees.pdf PDF
Questions and Answers.docx DOCX document
Attch 4 Corrected Drawings.zip ZIP file
Amendment 02.doc DOC document
Ammendment 0001.doc DOC document
Addendum 1 MWD Kennel.docx DOCX document
Questions and Answers.docx DOCX document
Questions and Answers.docx DOCX document
Attch 4 Drawings.zip ZIP file
Attch 7 - Subcontractor Consent Form - 10R0027.docx DOCX document
Attch 2 List of Submittals.xls XLS spreadsheet
Attch 1 Specifications.zip ZIP file
Attch 6 Past Performance Quest.docx DOCX document
Attch 3 Schedule of Drawings.doc DOC document
Attch 5 Wage Determination.docx DOCX document
Solicitation.doc DOC document
Show all 25

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Addendum for Dog Kennel Amendment 0003

1. Delete the demolition of the existing fence. Existing fence to remain. (Refer to C2.0)

2. Delete indicated fence for large yard area. (Refer to C3.0)

3. Delete sidewalks indicated by hatching. (Refer to C3.0)

4. Add approximately 40-feet of chain link fence and required posts as indicated. (Refer to C3.0)

5. Delete block screen wall at mechanical equipment area. (Refer to A1.3)

6. In lieu of EIFS and EIFS drainage mat, install 2-in rigid insulation and 22-gauge steel panel siding. Color of the siding to be Antique Linen-Federal Color 23578. (Refer to A3.1)

7. In lieu of CMU wainscot and cap, install 2-in rigid insulation and 22-gauge steel panel siding. Color to be Antique Linen-Federal Color 23578. (Refer to A3.2)

8. At Room 112 change floor from ceramic tile to sheet vinyl. Change walls from ceramic to green board sheet rock with paint P1. (Refer to A11.1)

9. At Room 114 change the floor to sheet vinyl except for the shower. In the latrine area change the walls from ceramic tile to green board sheet rock with paint P1. Shower area walls to remain unchanged. (Refer to A11.1)

10. Add painted steel hail guards to protect coils of the CU1 and CU2. Paint color to be Antique Linen-Federal Color 23578. (Refer to M4.1)

11. Delete lights, poles, and bases in the large yard area as indicated. (Refer to E1.1)