Addendum for Dog Kennel Amendment 0003.docx
DOCX document 11 KB Posted
- Attached to
- Replace Military Working Dog Kennel
- Solicitation number
- FA4626-11-R-0003
About this file
Addendum for Amendment
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Amendment 0003 Question and Answers.docx | DOCX document | |
| Bid Schedule.docx | DOCX document | |
| Amendment 003.doc | DOC document | |
| Drawings.pdf | ||
| Questions and Answers.docx | DOCX document | |
| Kennel Bore Logs.pdf | ||
| Bore Logs.docx | DOCX document | |
| Federal Government Shut Down.docx | DOCX document | |
| Site Visit Attendees.pdf | ||
| Dog Kennel Pre-Proposal.pptx | PPTX presentation | |
| Questions and Answers.docx | DOCX document | |
| Attch 4 Corrected Drawings.zip | ZIP file | |
| Amendment 02.doc | DOC document | |
| Addendum 1 MWD Kennel.docx | DOCX document | |
| Ammendment 0001.doc | DOC document | |
| Questions and Answers.docx | DOCX document | |
| Questions and Answers.docx | DOCX document | |
| Attch 3 Schedule of Drawings.doc | DOC document | |
| Attch 1 Specifications.zip | ZIP file | |
| Attch 5 Wage Determination.docx | DOCX document | |
| Attch 6 Past Performance Quest.docx | DOCX document | |
| Solicitation.doc | DOC document | |
| Attch 7 - Subcontractor Consent Form - 10R0027.docx | DOCX document | |
| Attch 4 Drawings.zip | ZIP file | |
| Attch 2 List of Submittals.xls | XLS spreadsheet |
Show all 25
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Addendum for Dog Kennel Amendment 0003
1. Delete the demolition of the existing fence. Existing fence to remain. (Refer to C2.0)
2. Delete indicated fence for large yard area. (Refer to C3.0)
3. Delete sidewalks indicated by hatching. (Refer to C3.0)
4. Add approximately 40-feet of chain link fence and required posts as indicated. (Refer to C3.0)
5. Delete block screen wall at mechanical equipment area. (Refer to A1.3)
6. In lieu of EIFS and EIFS drainage mat, install 2-in rigid insulation and 22-gauge steel panel siding. Color of the siding to be Antique Linen-Federal Color 23578. (Refer to A3.1)
7. In lieu of CMU wainscot and cap, install 2-in rigid insulation and 22-gauge steel panel siding. Color to be Antique Linen-Federal Color 23578. (Refer to A3.2)
8. At Room 112 change floor from ceramic tile to sheet vinyl. Change walls from ceramic to green board sheet rock with paint P1. (Refer to A11.1)
9. At Room 114 change the floor to sheet vinyl except for the shower. In the latrine area change the walls from ceramic tile to green board sheet rock with paint P1. Shower area walls to remain unchanged. (Refer to A11.1)
10. Add painted steel hail guards to protect coils of the CU1 and CU2. Paint color to be Antique Linen-Federal Color 23578. (Refer to M4.1)
11. Delete lights, poles, and bases in the large yard area as indicated. (Refer to E1.1)