ASBESTOS SURVEY REPORT

FOR

VANDENBERG AIR FORCE BASE, CALIFORNIA

BUILDING NO. 860

Prepared for:

Mr. Joseph Naputi

30 CES/CEVCC

1028 Iceland Avenue Vandenberg Air Force Base, California 93437-6010

Ms. Carol Cromer

CESAM-EN-GE

U.S. Army Engineer District, Mobile Post Office Box 2288

Mobile, Alabama 36628-0001

Prepared by:

TETRA TECH EM, INC.

10860 GOLD CENTER DR. SUITE 200

RANCHO CORDOVA, CALIFORNIA 95670

Contract No. FA4890-04-D-0006, ECAS Log No. 658, Task Order CK 18, FY08 Environmental Compliance and Miscellaneous Technical Support for AFSPC

March 7, 2009 i

CONTENTS

Section Page

1.0 SITE STRUCTURE

2.0 FINDINGS

3.0 ASSUMPTIONS AND DEVIATIONS

APPENDICES

Appendix

A FIGURES

B PHOTOLOG

C LABORATORY REPORTS AND CHAIN-OF-CUSTODY FORMS

TABLES

Table

1 ACM SAMPLE SUMMARY

2 NON-ACM SAMPLE SUMMARY

1.0 SITE STRUCTURE

Building 860 is a single-story, approximately 7,740 sq. ft. structure; built in 1959. The building is constructed of concrete masonry with a stucco finish. Interior finishes include drywall with skim coat walls. Flooring materials include carpet, floor tile, ceramic tile, and mastic. Bathrooms have ceramic tile and grout on the walls and floors. The occupants of this building have recently remodeled (still in-progress) the interior of this building.

The building was split up into three areas; the office area, the annex area and the attic area. The office area is represented by the main section of the building and includes offices, a kitchen, restroom, a fitness room and locker room. The annex area is attached on the east side to the office area and includes classrooms and a conference room. The attic area is located above the main office area. Homogenous materials were identified in each section and sampled accordingly.

2.0 FINDINGS

Six homogenous materials were identified in the assessment areas with a total of 6 samples being analyzed by the laboratory. Samples that exceed the EPA-defined asbestos containing material (ACM) level of 1.0% by polarized light microscopy (PLM) testing are summarized in Table 1 for all areas. Table

2 identifies all samples taken in each area that according to laboratory results do not contain asbestos.

The laboratory report shown in Appendix C contains the PLM results for all the suspect ACM samples collected from the building.

TABLE 1

ACM SAMPLE SUMMARY

Sample No. Material Description

Material Locations and Room Condition (G, P, or S)

Analytical Result

(% ACM)

Quantity (Sq.

Ft. or Lin. Ft.)

Friable (Yes/No)

Material Condition (G, P, or S) and Potential for

Disturbance (L, M, or H)

860-115-NF-CA

Yellow/Black Mastic under

Carpet

Throughout the office area of the building* – G 2% - Chry 7,740 Sq. Ft. No G – L

NA TSI - Joints Throughout the attic area of the building – G PACM Unknown Yes G – L

Notes:

ACM Asbestos-containing material PACM Presumed asbestos-containing material Chry Chrysotile asbestos Sq. Ft. Square feet Lin Ft Linear feet NA Not applicable G Good Condition P Poor Condition S Significant Damage L Low Possibility of Disturbance M Medium Possibility of Disturbance H High Possibility of Disturbance

* Sample number 860-115-NF-CA was taken as a carpet adhesive material sample, but it is this assessors professional opinion that the 2% Chry lab result is not the carpet adhesive, but mastic residue mixed in with the carpet adhesive left on the concrete from 9” x 9” floor tile taken out during a renovation that had asbestos present as stated in a previous survey.

Based on survey observations or the sample analytical results, Tetra Tech recommends removal of all

ACM listed in Table 1 by a licensed asbestos abatement contractor before any work disturbs the materials. If the ACM is not disturbed during any renovation processes, the ACM may be left in place.

TABLE 2

NON-ACM SAMPLE SUMMARY

Figure ID Number* Sample No. Material Description Analytical Result

(% ACM)

1 860-11-NW-CBM Cove Base Mastic ND 2 860-113-EW-CT Ceiling Tile ND 3 860-113-EW-DW Drywall ND 4 860-111-NW-SC Skim Coat ND 5 860-E-NW-WC Window Caulk ND

Notes:

ACM Asbestos-containing material ND Non-Detect for Asbestos

* This ID number corresponds to the ID numbers listed on the figure identifying where the sample was taken.

Based on these sample analytical results, Tetra Tech recommends no further action be taken if the non-

ACMs listed in Table 2 are disturbed.

3.0 ASSUMPTIONS AND DEVIATIONS

The following suspect and/or assumed ACMs were identified but not sampled for one or more of the following reasons: limitations on access; limitation on destructive sampling in a specific area because of use; prospect of damage unable to be repaired, thus leaving the possibility of a future asbestos fiber release; or previous analytical reports identifying the material as containing asbestos (PACM).

• Destructive Sampling Limitations: Stucco on the exterior walls; joint compound associated with the drywall in the office area; possible electrical wiring wrap throughout all areas of the building (safety issue); and ceramic tile and associated grout and mastic in the office area, specifically the bathrooms.

• PACM: Thermal system insulation (TSI) in the attic area on the joints of the domestic water pipes.

• Limitations on Access: The annex area was not accessible; all three rooms were occupied and were not to be disturbed.

The previous survey identifies the following materials as containing asbestos; the current survey did not identify these materials. Renovations have occurred since the previous survey; therefore the materials may have been removed.

• 9x9 floor tile and associated mastic in the office area

The roof was not accessible but appeared to be covered with gravel, a previous survey indicated that roofing sealant was present and contained asbestos. The previous survey also indicates that the wallboard in rooms 104 and 105 of the annex area contains 2% chrysotile asbestos. This area was inaccessible due to a class in session.

Samples of the suspect ACMs not sampled during this survey should be taken by a licensed asbestos inspector, prior to any disturbance of the materials to determine if the material contains asbestos.

APPENDIX A

FIGURES

Figure 1 Building 860

X :\S

\0

0\

FH

\F ig ur e1 _8

.F

H

Asbestos Survey Vandenberg Air Force Base near Lompoc, California

Date: 01/30/09 Drawn By: Ingrid Tobar Project No: 103I0770.001

Not to Scale

Legend

Asbestos Containing Material Sample Location Non-asbestos Containing Material (sample number corresponds to sample’s taken listed in Table 2 of the report, that do not contain asbestos) Pressumed Asbestos Containing Materials PACM (TSI-Joints)

PACM

Classroom 1

860-115-NF-CA

(Mastic from previous 9x9 floor tile)

Classroom 2

Conference Room

Training Simulator Room

Men’s Restroom

Women’s Restroom

Physical Fitness Room

Crew Office

Supt’s Office

Dayroom

Kitchen

Tool Room

Supply Room

Locker Room

APPENDIX B

PHOTOLOG

Asbestos Survey Report Building No. 860

Vandenberg Air Force Base, California

TETRA TECH

This photograph shows the carpet over previously abated 9” x 9” floor tile and mastic in the physical fitness room 115 of the office area that has asbestos present mixed in with the carpet adhesive.

Date 1/27/09

DESCRIPTION

APPENDIX C

LABORATORY REPORTS AND CHAIN-OF-CUSTODY FORMS

1.0 SITE STRUCTURE
2.0 FINDINGS
3.0 ASSUMPTIONS AND DEVIATIONS