Bookle Section 4. Code Search.doc

DOC document 61 KB Posted

Attached to
Design and Construct an 14, 025 SF NAF Child Development Center (CDC) at Barksdale AFB, Louisiana
Solicitation number
FA4608-09-R-0027
Issued by

About this file

Booklet - Code Search

View the file

Other files

File Type Posted
CDC QUESTIONS.docx DOCX document
CDC QUESTIONS.docx DOCX document
CDC QUESTIONS.docx DOCX document
Appendix to Child Development Center BAFB.doc DOC document
Response to Question 2.docx DOCX document
Amendment 0002.doc DOC document
Barksdale AFB_Design Compatibility Guidelines_March 2006.pdf PDF
Correction to - Response to Question 1.docx DOCX document
Response to Question 1.docx DOCX document
P3.01.pdf PDF
M2.02.pdf PDF
bafb tblk24x36-1-B afjmc.dwg DWG drawing
E3.01.pdf PDF
E7.02.dwg DWG drawing
A1.06.dwg DWG drawing
M3.03.dwg DWG drawing
C1.01.dwg DWG drawing
S3-01.dwg DWG drawing
Site photo Child Development Center RFP.pdf PDF
XSITE.dwg DWG drawing
S2-01.pdf PDF
E2.01.dwg DWG drawing
M3.04.pdf PDF
A0.01 Cover.dwg DWG drawing
A1.08.pdf PDF
M2.01.pdf PDF
A1.07.pdf PDF
A1.03.pdf PDF
C1.00.dwg DWG drawing
M3.02.dwg DWG drawing
DEMOPLAN.pdf PDF
Design Build RFP Iindex.doc DOC document
Booklet Section 1 Meeting Minutes 03.24.09.pdf PDF
S1-01.dwg DWG drawing
S2-01.dwg DWG drawing
A1.02.pdf PDF
P2.02.dwg DWG drawing
E7.02.pdf PDF
Standard Template CDC 5-28-09.pdf PDF
S1-02.pdf PDF
M3.01.pdf PDF
A1.04.pdf PDF
S1-02.dwg DWG drawing
E7.01.dwg DWG drawing
P1.01.dwg DWG drawing
M1.01.dwg DWG drawing
E4.01.dwg DWG drawing
M3.03.pdf PDF
A1.08.dwg DWG drawing
A1.06.pdf PDF
Show 40 more

Latest 50 of 110 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Code Category

N.F.P.A. 101 (2006 Edition)
International Building Code (2006 Edition)
International Building Code (2006 Edition)
UFC 4-740-14
Occupancy Classification:
• Day-Care Occupancy (6.1.4)
• Group E- Educational Occupancy
Group I-4 – Institutional Occupancy
Daycare
Construction Type:
• Type II(000) (Commentary Table 8.1)
• Type IIB (Table 601)
• Type IIB (Table 601)
Allowable Height & Area:
• N/A
• 2 Stories and 14,500 s.f. (Table 503)
• 2 Stories and 13,000 s.f. (Table 503)
Hazard Classification:
• Ordinary Hazard (16.1.5)
•
Occupant Load:
• 35 s.f. net per person (Table 7.3.1.2)
• 35 s.f. net per person (Table 1004.1.1)
• 35 s.f. net per person (Table 1004.1.1)
35 S.F. per person
Exit Capacity:
• .2” / person for level components and ramps

• .3” / person for stairways

• Minimum door width = 36” (xx” clear) (7.3.3.1)

• .15” / person for other egress components

• .2” / person for stairs

• Minimum door width = xx” (32” clear) (Table 1005.1)

• .15” / person for other egress components

• .2” / person for stairs

• Minimum door width = xx” (32” clear) (Table 1005.1)

Number of Exits:
• 2 Minimum (16.2.4)
• 2 Minimum for 1-500 occupants per story (Table 1019.1)
• 2 Minimum for 1-500 occupants per story (Table 1019.1)
Dead End Corridor:
• 20’ (50’ sprinkled) (16.2.5.2)
• 20’ (1017.3)
• 20’ (1017.3)
Not permitted
Common Path of Travel:
• 75’ , other than for the first 100 ft. in a building protected throughout by an approved, supervise automatic sprinkler system (16.2.5.3)
• 75’ (1014.3)
• 75’ (1014.3)
Exit Access Corridors:
• 1 Hour Rated in nonsprinkled building (16.3.6)

No rating required in sprinklered buildings

• Non rated corridors allowed (Table 1017.1)

• Corridors need not be rated in Group E occupancies with rooms used either for instruction with at least one exit door directly to the exterior at ground level or for assembly purposes with at least one-half of the required exits directly to the exterior at ground level (1017.1)

• Non rated corridors allowed (Table 1017.1)
Main corridor to be 8 feet wide minimum
Travel Distance:
• Between any room door intended as an exit access and an exit shall not exceed 100 ft. (150’ sprinkled)

• Between any point in a room an exit shall not exceed 150 ft. (200’ sprinkled)

• Between any point in a sleeping room and an exit access door in that room shall not exceed 50 ft

(16.2.6.2)

• 200’ (250’ sprinkled) (Table 1016.1)
• 150’ (200’ sprinkled) (Table 1016.1)
Illumination of Means of Egress
• See Section 7.8
• See Section 1006
• See Section 1006
Emergency Lighting:
• Required per 7.9 for interior stairs and corridors, assembly use spaces, flexible and open plan buildings, interior or limited access portion of building, and shops and laboratories (16.2.9)
• See Section 1006
• See Section 1006
Comply with NFPA 101
Special Means of Egress Features
• Windows for Rescue for nonsprinkled buildings and rooms or spaces without a door leading directly to the outside of the building : Every room or space normally subject to client occupancy, other than bathrooms, shall have not less than one outside window for emergency rescue that complies with the following

1. Windows shall be openable from the inside without the use of tools and shall provide a clear opening of no less than 20 in. in width, 24 in. in height , and 5.7 s.f. in area.

2. The bottom of the opening shall be not more than 44 in. above the floor.

3. The clear opening shall allow a rectangular solid, with a width and height that provides not less than the required 5.7 s.f. opening and a depth of not less than 20 in. to pass fully through the opening.

(16.2.11.1)

Exit Signs:
• Required other than main exterior exit doors that obviously and clearly are indefinable as exits, and where a main entrance serves also as an exit. (7.10.1)
•Required at exit and exit access door except in rooms or areas that require only one exit or exit access and main exterior exit doors or gates that are obviously and clearly indefinable a exits need no have exit signs where approved by the building official. (1011.1)
•Required at exit and exit access door except in rooms or areas that require only one exit or exit access and main exterior exit doors or gates that are obviously and clearly indefinable a exits need no have exit signs where approved by the building official. (1011.1)
Protection from Hazards
• See 16.3.2
• See Section 414
• See Section 414
1 Hour Separation at Laundry Rooms
Interior Finish
Wall and Ceiling Finish:

• Stairways, corridors, and lobbies – Class A

• All other Occupied areas – Class A or B

Floor Finish:

• Exit enclosure and exit access corridors – Class II(16.3.3)

• Exit Enclosures and Exit Passageways – ClassB

• Corridors – Class C

• Rooms and Enclosed Spaces – Class C

(Table 803.5)

• Interior Floor Finish – Class I or II (804.2)

• Exit Enclosures and Exit Passageways – Class B

• Corridors – Class B

• Rooms and Enclosed Spaces – Class B(Table 803.5)

• Interior Floor Finish – Class I or II (804.2) Same as NFPA 101

Extinguishing Requirements
• Automatic sprinklers per NFPA 13

• Portable fire extinguishers per NFPA 10

• Required per International Fire Code
• Required per International Fire Code
Detection, Alarms and Communications
• Fire alarm system required per 9.6

• Detectors installed on each floor in front of the doors to the stairways and in the corridors of all floors, lounges, recreation areas, and sleeping rooms

• Notification: Audible and visible per NFPA 72

• Initiation: Manual means and by operation of any required smoke detectors and required sprinkler systems (16.3.4)

• See Section 907
• See Section 907
Staffing Requirements
• Staff-to-Client Ratio Age (mo.)

(Table A.16.1.1.)

1:3 0-24

1:4 25-36

1:7 37-60

1:10 61-96

1:12 ≥97

1:3 Clients incapable of self- preservation

Plumbing Fixtures Required

Louisiana State Plumbing Code, 2000 edition

Water Closets:

Ages 0-4 Fixtures

1-20 1

21-40 2

41-80 3

For each additional 40 children add 1 fixture

Ages 5-up Fixtures

1-40 1 Male, 1 Female

41-80 1 Male, 2 Females

81-120 2 Males, 3 Females

121-160 2 Males, 4 Females

For each additional 40 females add 1 fixture

For each additional 80 males add 1 fixture

Lavatories:

Ages 0-4 Fixtures

1-21 1

21-40 2

41-80 3

For each additional 40 children add 1 fixture

Ages 5-up Fixtures

1-41 1 Male, 1 Female

41-81 1 Male, 2 Females

81-121 2 Males, 3 Females

121-161 2 Males, 4 Females

For each additional 40 females add 1 fixture

For each additional 80 males add 1 fixture

Lavatories in Kitchen:

1 in each food preparation and utensil washing area located to permit convenient use by all food and utensil handlers

Lavatories in caring for infants:

1 in or adjacent to each diaper changing area but never to be located in a food preparation/storage or utensil washing area.

Bathtubs, Showers and Miscellaneous Fixtures:

Kitchen:

7-15 children- 3 compartment sink (or approved domestic or commercial dishwashing machine and a 2 compartment sink

16-up children- 3 compartment sink (dishwashing machine, if provided, must be a commercial type)

One laundry tray, service sink, or curbed cleaning facility with floor drain on premises for cleaning mops/mop water disposal.

Caring for infants:

One extra laundry tray, service sink, or similar fixture is required to clean and sanitize toilet training potties immediately after each use. Such fixtures shall be dedicated solely for this purpose and shall not be in the food preparation/storage, utensil washing, or dining areas.