07200.pdf

PDF 53 KB Posted

Attached to
RECOVERY - SGBP970107 - Repair J-Wing Elec, Strat
Solicitation number
FA4600-09-B-0006
Issued by

About this file

Attachment 1 Specs

View the file

Other files

File Type Posted
QA 2 Repair J Wing Electrical RFI.doc DOC document
QA RECOVERY Repair J Wing Electrical RFI.doc DOC document
OFF-B-6073 Sheet 02 - Amendment 1 - May 09.dwf DWF file
OFF-B-6073 Sheet 04 - Amendment 1 - May 09.dwf DWF file
FA4600-09-B-0006-0003.pdf PDF
OFF-B-6074 Sheet 03 - Amendment 1 - May 09.dwf DWF file
OFF-B-6073 Sheet 05 - Amendment 1 - May 09.dwf DWF file
OFF-B-6074 Sheet 01 - Amendment 1 - May 09.dwf DWF file
OFF-B-6073 Sheet 06 - Amendment 1 - May 09.dwf DWF file
OFF-B-6073 Sheet 01 - Amendment 1 - May 09.dwf DWF file
amend 0002.doc DOC document
Site Visit Sign in.pdf PDF
Amendment 1.doc DOC document
08100.pdf PDF
Section 1A J-WING BJ-1J.pdf PDF
Sheet 05-5.dwf DWF file
09650.pdf PDF
Section 1C J-WING BJ-1J.pdf PDF
16010 Final General Electrical.pdf PDF
Sheet 04-4.dwf DWF file
09000.pdf PDF
Sheet 06-6.dwf DWF file
Sheet 07-7.dwf DWF file
02110.pdf PDF
Sheet 05-5.dwf DWF file
16452 Final Grounding.pdf PDF
16135 Final Electrical Boxes and Fittings.pdf PDF
Sheet 02-2.dwf DWF file
09900.pdf PDF
Sheet 09-Layout.dwf DWF file
16361 Final Secondary Unit Substations.pdf PDF
09250.pdf PDF
16470 Final Panelboards.pdf PDF
Section 1B J-WING BJ-1J.pdf PDF
Sheet 07-7.dwf DWF file
16120 Final Wires and Cables.pdf PDF
Section 1 AF66 J-WING bj-1j.xls XLS spreadsheet
16190 Final Supporting Devices.pdf PDF
Sheet 03-3.dwf DWF file
Sheet 01-01.dwf DWF file
16482 Final Motor Control Centers.pdf PDF
06300.pdf PDF
Sheet 04-4.dwf DWF file
16110 Final Raceways.pdf PDF
Sheet 06-6.dwf DWF file
16124 Final Medium Voltage Cables.pdf PDF
Atch 4 General Decision Number.doc DOC document
Atch 5 offeror checklist.doc DOC document
TOC - Repair Electrical J-Wing Stratcom Floors BJ 1J.pdf PDF
Sheet 08-8.dwf DWF file
Show 40 more

Latest 50 of 62 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

112-006 07200-1

DIVISION 7 – THERMAL AND MOISTURE PROTECTION 1

SECTION 07200 3

BUILDING INSULATION 4

A. GENERAL 6

RELATED PRODUCTS SPECIFIED ELSEWHERE 8

Gypsum Drywall Section 09250 10

QUALITY ASSURANCE 12

All insulating materials and methods of installation shall comply with all applicable building and fire codes. 14

PRODUCT DELIVERY, STORAGE AND HANDLING 16

Protect insulation from physical damage and from becoming wet, soiled, or covered with ice or snow. Comply with 18 the manufacturer’s recommendations for handling, storage and protection during installation. 19

B. PRODUCTS 21

BATT INSULATION 23

Sound batts for vertical installation between studs shall be unfaced R-11 fiberglass batt insulation. At 6” stud 25 walls, use unfaced R-19 batts. Batt insulations thall be the manufacturer’s standard lengths and widths as 26 required to coordinate with spaces to be insulated and shall be one of the following types and manufactures (or 27 approved equal): 28 FS-25 Building Insulation Owens-Corning Fiberglass 29 FSK-25 Batt Insulation Manville Corporation 30 Batts shall be widths as required to tightly fit between studs, except that at all locations where gypsum drywall is 32 not shown on both sides of the partition, batts shall be supplied with foil on one face. 33 All batt insulation shall have maximum flame spread rating of 5 and smoke-developed rating of 15 per ASTM E 84. 35 Where batt insulation is included in rated wall, ceiling or floor construction, provide mineral wool batts which have 37 been tested and rated as required for the indicated assembly. 38

C. EXECUTION 40

PREPARATION 42

Clean substrate of substances harmful to insulations or vapor barriers, including removal of projections which 44 might puncture vapor barrier. 45

GENERAL 47

Comply with manufacturer’s written instructions for particular conditions of installation in each case. If printed 49 instructions are not available or do not apply to project conditions, consult manufacturer’s technical representative 50 for specific recommendations before proceeding with work. 51 Extend insulation full thickness as shown over entire area to be insulated. Cut and fit tightly around obstructions, 53 and fill and close voids with insulation. 54 Apply insulation units to substrate by method indicated, complying with manufacturer’s written recommendations. 56 If no specific method is indicated, bond units to substrate with adhesive or use mechanical anchorage to provide 57 permanent placement and support of units. 58

112-006 07200-2

Do not obstruct ventilation spaces except for firestopping. 1

INSTALLATION OF BATT INSULATION 3

Install batt insulation at the locations shown on the Drawings with vapor barriers on room side. Tightly fit into place 5 and push down in vertical spaces to assure avoidance of future settling. Securely staple in place as 6 recommended by the insulation manufacturer. Maintain all required minimum clearance between insulation and 7 fans, lights or other heat-producing equipment items. At locations where studs are less than full stud depth, strip 8 part of the insulation off of the non-vapor barrier side to reduce the total thickness to 1/2" greater than the available 9 space. 10

PROTECTION 12

Protect installed insulation and vapor barriers from possible physical abuses, where possible by non-delayed 14 installation of concealing work or, where that is not possible, by temporary covering or enclosure. Installer shall 15 advise Contractor of exposure hazards, including possible sources of deterioration and fire hazards. 16