E-100 rev2.pdf
PDF 196 KB Posted
- Attached to
- Renovate Building T-715 Federal contract opportunity
- Solicitation number
- FA448620R0014
About this file
This document package includes an electrical schematic and luminaire schedule for the renovation of Building T-715, along with the related federal contract solicitation.
The electrical schematic and luminaire schedule provide specifications for lighting fixtures, switches, receptacles, and other electrical components to be used in the renovation of Building T-715. The schematic includes labels for various electrical symbols and notes with requirements. The luminaire schedule lists over 25 lighting fixtures with manufacturer names, catalog numbers, voltages, wattages, and mounting details.
The related federal contract solicitation is seeking proposals for the renovation of Building T-715 located at Lajes Field in the Azores, Portugal. A single award firm fixed price contract will be issued, with a magnitude between $1 million and $5 million. The NAICS code is 236220. Proposals are due by the date specified in Section L and will be evaluated based on the factors in Section M. The contract will incorporate the specifications, drawings, and submittal requirements dated 24 January 2020. The soliciting agency is the Department of the Air Force United States Air Forces in Europe - Air Forces Africa.
View the file
Other files for this federal contract opportunity
Show all 28
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
LUMINAIRE SCHEDULE
LABEL MANUFACTURER CATALOG NO. VOLTAGE
LAMPS MOUNTING
NO. TYPE TYPE HEIGHT IN WATTS
A LLEDO 3455K57840020 220-240 1 LED RECESSED CEILING 50
B LLEDO 3455K35840020 220-240 1 LED RECESSED CEILING 29
B1 LLEDO 3455K35840220 220-240 1 LED RECESSED CEILING 29
C LLEDO 3454K22840020 220-240 1 LED RECESSED CEILING 20
F LLEDO 3649K28840200BM 220-240 1 LED RECESSED CEILING 27
H LLEDO 296302584021008 220-240 1 LED SUSPENDED 6'8" 25
K EEE APL 01 05024-O7 220-240 1 LED WALL 5'3" 10
L LLEDO 8550040840000 220-240 1 LED SURFACE CEILING 40
X PHILIPS
HBL-128GL 53 NW-UNV
NC-WT
220-240 4 LED SURFACE CEILING 287
Z OPPLE 140062030 220-240 1 LED WALL 90
ELECTRICAL LEGEND
DUPLEX RECEPTACLE 20AMP 125V - 18" AFF U.O.N.
WITH GROUND FAULT PROTECTION
WP
GFI
LIGHTING CONTACTOR
TIME CLOCK
LED RECESS LIGHT FIXTURE 2X4
RECESSED DOWN LIGHT SEE SCHEDULE FOR TYPE
MOTOR CONNECTION
JUNCTION BOX
FLEX CONNECTION, SIZE SAME AS FEEDER
PANELBOARD, SURFACE MOUNTED
MAIN DISTRIBUTION PANEL
BRANCH CIRCUIT, CONCEALED ABOVE CEILING OR IN WALL
WHERE POSSIBLE, WHERE EXPOSED ROUTE PARALLEL
& PERPENDICULAR TO STRUCTURE.
CONDUIT TURN UP
CONDUIT TURN DOWN
EXIT LIGHT SEE SCHEDULE
LIGHT SWITCH (WALL MOUNTED 48" AFF) SINGLE POLE 20A 277V
LIGHT SWITCH (WALL MOUNTED 48" AFF) DOUBLE LOW VOLTAGE DIGITAL
LIGHT SWITCH (WALL MOUNTED 48" AFF) THREE WAY
LIGHT SWITCH (WALL MOUNTED 48" AFF) , 'D' INDICATES DIMMER
EMERGENCY LIGHT, WALL MOUNTED -96" AFF
PHOTO CELL
BRANCH CIRCUIT, HOMERUN, 3/4"C. 2#12,#12G. MIN.
1.
2.
3.
4.
THE ELECTRICAL CONTRACTOR SHALL BECOME FAMILIAR WITH THE
ARCHITECTURAL DRAWINGS PRIOR TO THE INSTALLATION OF THE
ELECTRICAL SYSTEMS.
THE MINIMUM CONDUIT SHALL BE 3/4" WITH 3 #12 THHN OR THWN
CONDUCTORS FOR SINGLE PHASE LOADS AND 4 #12 FOR THREE PHASE LOADS.
PROVIDE GFI PROTECTED RECEPTACLES PER N.E.C./R.T.I.E.B.T.
RECEPTACLE AND SWITCH BOXES SHALL BE ROUGHED IN FLUSH WITH WALL
SURFACE.
PROVIDE ALL NECESSARY SUPPORTS AS REQUIRED FOR LIGHT FIXTURES,
CONDUIT, DISCONNECTS, ETC.
VERIFY DOOR SWINGS WITH ARCHITECTURAL PLANS
AND MANUFACTURER SHOP DRAWINGS FOR PROPER LOCATION OF SWITCHES.
FIELD ADJUST THE LIGHT FIXTURE LAYOUT TO
CLEAR ANY BEAMS, COLUMNS, PIPING, ETC. THAT MIGHT BE IN THE WAY.
REFER TO THE APPROPRIATE DRAWING FOR THE EXACT LOCATION OF EQUIPMENT
INSTALLED UNDER DIVISIONS OF THE DOCUMENTS WHICH REQUIRE ELECTRICAL SERVICE.
5.
6.
7.
8.
9.
10.
MOTOR RATED SWITCH
11.
12. CONDUCTOR AND CONDUIT SHALL BE INCREASED IN SIZE TO ACCOMMODATE
VOLTAGE DROP.
FIXTURES FINISH SHALL BE COORDINATED WITH ARCHITECT.
BRANCH CIRCUIT, GROUND, 3 PHASE, NEUTRAL,
3/4"C. 4#12,#12G. MIN.
BRANCH CIRCUIT, GROUND, 1 PHASE, NEUTRAL
3 SWITCH LEG CONDUCTORS 3/4"C. 4#12,#12G. MIN.
CONDUIT STUB-UP AND CAP, TERMINATION
ABOVE FINISHED GRADE TO CENTERLINE
CONDUIT
CIRCUIT
CIRCUIT BREAKER
DISCONNECT
EXHAUST FAN
ELECTRIC UNIT HEATER
GROUND FAULT CURRENT INTERRUPTING
GROUND
HORSEPOWER
MAIN LUGS ONLY
PANEL
UNDERGROUND
WITH
WEATHERPROOF
TRANSFORMERXFMR
WP
UG
MLO
HP
GFI
EWH
EUH
EF W/
PNL
GND
DISC
C/B
AFG
CKT
C
UON
EWC
AHU
RCP
AIR HANDLING UNIT
ELECTRIC WATER COOLER
REFLECTED CEILING PLAN
UNLESS OTHERWISE NOTED
WITH WEATHERPROOF WHILE IN USE COVER
LED 4 FOOT STRIP
ELECTRIC WATER HEATER
ELECTRICAL WORK SHALL CONFORM TO THE N.E.C./R.T.I.E.B.T. AS A MINIMUM STANDARD.
ITEMS SPECIFIED BY BRAND NAME ARE ON AN "OR EQUAL" BASIS
(UNLESS OTHERWISE NOTED).
EMERGENCY AND EXIT LIGHTS SHALL BE CIRCUITED AHEAD OF THE SWITCHES.
PROVIDE JUNCTION BOXES AS INDICATED OR REQUIRED.
SIZE PER NEC ARTICAL 370.
13.
POLE MOUNTED
BRANCH CIRCUIT, CONCEALED BELOW SLAB, OR BELOW GRADE
W
RECESSED WALL WASHER DOWN LIGHT SEE SCHEDULE FOR TYPE
WALL MOUNTED LIGHT SEE SCHEDULE FOR TYPE
SUSPENDED DIRECT/INDIRECT LIGHT SEE SCHEDULE FOR TYPE
DUPLEX RECEPTACLE 20AMP 125V - VERIFY MOUNTING HEIGHT
DUPLEX RECEPTACLE 20AMP 125V - 60" AFF
REF
MW
WITH LOCATION OF MICROWAVE PRIOR TO ROUGH IN.
FIRE ALARM CONTROL PANEL
FIRE ALARM COMBINATION SPEAKER STROBE
FIRE ALARM STROBE
MANUAL PULL STATION
FIRE ALARM ANNUNCIATOR PANEL
HVAC RETURN DUCT SMOKE DETECTOR
HVAC SUPPLY DUCT SMOKE DETECTOR
CEILING MOUNTED SMOKE DETECTOR
CEILING MOUNTED HEAT DETECTOR
POWER PANEL
D
120V-POWER OUTLET 20 NEMA 5-20R FLOOR MOUNTED OUTLET
LV
LV2
LIGHT SWITCH (WALL MOUNTED 48" AFF) LOW VOLTAGE DIGITAL
DUPLEX RECEPTACLE 20AMP 125V - 18" AFF U.O.N.
POWER DISTRIBUTION UNIT
G
SURFACE MOUNTED ROOF AIR TERMINAL
GROUND ROD
BURIED GROUND CONDUCTOR
TRIPOD MOUNTED ROOF AIR TERMINAL
120V-POWER OUTLET 20 NEMA 5-20R MOUNTED AT 48" AFF UNLESS NOTED OTHERWISE
LABEL POWER AND SWITCH OUTLETS WITH RESPECT TO
CIRCUIT BREAKER AND PANEL LOCATION.
14.
P1
OCCUPANCY SENSOR POWER PACK TYPE "P1" SEE DETAIL SHEET
OCCUPANCY SENSOR, DUAL TECHNOLOGY, SEE DETAIL SHEET
M
GROUND BUS
120V-POWER OUTLET 20 NEMA 5-20R OUTLET AND SECURE DATA JACK MOUNTED
IN FLOORBOX. FSR MODEL NUMBER FL540P-4 (BOX), FL540P-BLP-C (LID)
WALL MOUNTED SCONCE
PENDANT MOUNTED LUMINAIRE
SEE SCHEDULE FOR TYPE
SEE SCHEDULE FOR TYPE
RECESSED DOWN LIGHT SEE SCHEDULE FOR TYPE
CATEGORY 6 CABLE
C
C
C
120V-POWER OUTLET 20 NEMA 5-20R CEILING MOUNTED OUTLET
SOUND MASKING DEVICE;
WALL AND DOOR MOUNTED
SM
SOUND MASKING DEVICE;
DUCT MOUNT
SM
D
SOUND MASKING SPEAKER
SM
SOUND MASKING GENERATORSMG
EMERGENCY POWER OFF
EPO
M
F
F
32A, 400V EUROPEAN RECEPTACLE
DUPLEX, 120V, NEMA 5-20R ON DEDICATED CIRCUIT
TWIST LOCK DUPLEX, 120V, NEMA L5-20R ON DEDICATED CIRCUIT
L
L
208V, NEMA L6-30R
NEMA L15-30R
NEMA L21-30R
NEMA L15-20R
60 AMP, 120/240V OUTLET
INDICATES TO MOUNT RECEPTACLE IN ABS BOX ON
FLEX WHIP UON (TYPICAL)
ELECTRICAL SYMBOLS
QUADPLEX RECEPTACLE 20AMP 125V - 18" AFF U.O.N.
ELECTRICAL ABBREVIATION
ELECTRICAL NOTES
FIRE ALARM SYMBOLS
GROUNDING & LIGHTNING PROTECTION SYMBOLS
SECURITY
DUPLEX RECEPTACLE 20AMP 125V - COORDINATE HEIGHT WITH
SECURITY CONTRACTOR PRIOR TO INSTALLATION
CAMERA
CONDUITS LEAVING OR ENTERING BUILDING SHALL BE SEALED
PER NEC TO PREVENT ENTRANCE OF MOISTURE.
15.
TS TAMPER SWITCH
FS
FLOW SWITCH
PS
DRY PIPE PRESSURE SWITCH
ELECTRICAL SYMBOLS (con't)
ABOVE FINISHED FLOOR TO CENTERLINEAFF
ELECTRIC UTILITY METER
FIRE ALARM RADIO FREQUENCY ANTENNA
ABOVE FINISHED SLAB TO CENTERLINEAFS
STAINLESS STEEL (316)SS
OVERHEAD POWER LINE
CONTROL/COMMUNICATION WIRING PER VENDOR STANDARDS
WALL UNSECURED PHONE +48" - 1 CAT 6 RJ-45 DATA DROP
GROUND BUS
MULTIMODE FIBER 10/2 FIBER DROP
SECURE DATA DROP - 2 CAT 6 ORANGE SHIELDED CABLE,
UNSECURE DATA DROP - 2 CAT 6 RJ-45 DATA DROPS
PHONE DROP - 2 CAT 6 RJ-45 DATA DROP
INDICATES TO MOUNT OUTLET IN ABS BOX IN FLOOR
(TYPICAL)
AK
AC
CAMERA, FIXED
ACCESS ALARM KEYPAD, 471210-F
ALARM MOTION DETECTOR, 669SIM-ADT
ALARM DOOR CONTACT, MAGNASPHERE HSS-L1.5-121
ALARM PANEL
ACCESS ELECTRIC STRIKE
ACCESS CONTROL J-BOX
IR1
DC
AP
ES
ALARM MOTION MOUNTED UNDER ACCESS FLOORIRF
CAMERA, POINT/TILT/ZOOM
PTZ
ACAS CARD READERCR
ACAS CARD READER WITH PINPADCRP
ACCESS ELECTRIFIED HINGEEH
SL ACCESS STATUS INDICATOR LIGHT, 7201xL2-H
ACCESS MAGNIFIED LOCKMAG
ALARM OVERHEAD DOOR CONTACT BRACKET, HS-1271DC
OH
ALARM MOTION DETECTOR, 450SIM-ADTIR2
ALARM MOTION DETECTOR, 633SIMA-ADTIR3
FIX
ACCESS CONTROL REQUEST TO EXIT DEVICE, WALL MOUNTED PUSH BUTTONRTE
ACCESS CONTROL REQUEST TO EXIT DEVICE, CEILING MOUNTED MOTION ACTIVATERTE
DATA SYMBOLS
ACAS/SECURITY SYMBOLS
UNSECURED DATA DROP - COORDINATE HEIGHT
AND LOCATION WITH SECURITY CONTRACTOR
SECURITY
CAMERA
PRIOR TO INSTALLATION
AUDIO VISUAL RECESSED WALL BOX - PROVIDE WITH
THREE GANGS SUITABLE FOR POWER, DATA AND AUDIO
VISUAL CABLING, LEGRAND TV3W OR EQUAL. VERIFY
HEIGHT PRIOR TO INSTALLATION
RED CONNECTOR, RED FACEPLATE
MAGNETIC DOOR HOLDER
FIRE PROTECTION RISER
FIRE PROTECTION RISER WITH HANDLE
A
HD
DOUBLE RECEPTACLE EUROPEAN 16AMP 230V - 18" AFF U.O.N.
CEILING FAN
EXHAUST FAN
EF
MOTOR STARTER, COMBINATION TYPE STARTER & DISCONNECT
SEE MECHANICAL AND PLUMBING SCHEDULES FOR SIZING
DISCONNECT SWITCH, FUSIBLE, SEE MECHANICAL AND PLUMBING
SCHEDULES FOR SIZING
DISCONNECT SWITCH, NON-FUSIBLE, SEE MECHANICAL AND PLUMBING
PLANS FOR SIZING
PANEL
FRONT VIEWSIDE VIEW
FINISHED
FLOOR
P
A
N
E
L
HEIGHT OF
PANEL
SIDE VIEWFRONT VIEW
REQUIRED
CLEARANCE
FINISHED
FLOOR
PANEL
SLAB ABOVE
EXCLUSIVELY
DEDICATED
SPACE
SLAB ABOVE
4'-0" (1.3m) FOR 1 51-600V
NOMINAL PANEL
P
A
N
E
L
.8 m (30") WHICH DOES NOT
HAVE TO BE CENTERED
ON EQUIPMENT.
WALL
6'-6" (2m)
MIN.
NTS
TYPICAL PANELBOARD REQUIRED CLEARANCE DETAIL
4" (102mm) MINIMUM, 12" (305mm) MAXIMUMCEILING
WALL MOUNTED SMOKE DETECTOR
FIRE ALARM MANUAL PULL STATION
MISCELLANEOUS
TELEPHONE OUTLET
THERMOSTAT
RECEPTACLE
WALL SWITCH
DATA OUTLET
m m
48" (1220mm) MAXIMUM UNLESS LOCATED ABOVE
"OBSTRUCTION" SUCH AS A COUNTER, THEN 42" (1050mm)
MAXIMUM, UNLESS OTHERWISE INDICATED IN EACH CASE
48" (1.3m) m
M A
X I M
U M m m
M A
X I M
U M
FIRE
F
I
R
E
FINISHED FLOOR
NOTES:
1. DEVICES SHOWN MAY NOT ALL BE USED
2. DETAIL INDICATES TYPICAL MOUNTING HEIGHTS ONL Y
m
M A
X I M
U M m m
M A
X I M
U M
84" (2.2m)
NTS
DEVICE MOUNTING HEIGHT DETAIL
PHOTOGRAPH CAMERA LOCATION AND ORIENTATION MARKER
ROOF AIR TERMINAL
E-100
TYPICAL FOR ALL SHOWNTYP
LED RECESS LIGHT FIXTURE 2X2
MASS NOTIFICATION LOCAL OPERATOR CONTROL PANEL
WITH MASS NOTIFICATION STROBE
FIRE ALARM COMBINATION SPEAKER STROBE
F
WITH MASS NOTIFICATION STROBE. WEATHERPROOF
WP
Project No.: MQNA 13-1017 Designed By: 65 CENP
Drawn By: 65 CENP
Checked By: 65 CES
A
B
C
D
E
F
G
1 2 3 4 5 6 7 8
Bar Measures 1 inch
BUILDING T-715
U.S. Air Forces in Europe Lajes Field, Azores, PT
REPAIR/MODERNIZATION
MARK DATE DESCRIPTION BY
1 24 JAN 20 FINAL - FOR CONSTRUCTION CENP
WALL MOUNTED CLOCK
AND FIRE ALARM STROBE
TV OUTLET
60" (1.5m)
E-001
E-001
2 11 FEB 20 FINAL - FOR CONSTRUCTION - REV 1 CENP
LIGHT FIXTURE WITH HATCHING INDICATES EMERGENCY BATTERY BACK-UP UNIT,
PROVIDE AN UNSWITCHED CONDUCTOR TO EACH EMERGENCY BATTERY PACK
3 29 SEP 20 FINAL - FOR CONSTRUCTION - REV 2 CENP
AutoCAD SHX Text C
AutoCAD SHX Text
TC
AutoCAD SHX Text P
AutoCAD SHX Text S
AutoCAD SHX Text M
AutoCAD SHX Text J
AutoCAD SHX Text R
AutoCAD SHX Text
FAA
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text
FACP
AutoCAD SHX Text S
AutoCAD SHX Text P
AutoCAD SHX Text P
AutoCAD SHX Text J
AutoCAD SHX Text
AV
AutoCAD SHX Text
LOC
| Sheets and Views |
| E-100 |
File details come from the government source that posted it. Updated .