This is a technical specification document (Section 08 11 13) detailing requirements for steel doors and frames for a dorm renovation project at Joint Base McGuire-Dix-Lakehurst. The specification requires standard steel doors that are 1-3/4 inch thick with a minimum 25% recycled content, and frames must be Level 1 knock-down field-assembled corners with zinc-coated anchors.

The document outlines detailed requirements for door hardware preparation, finishes, fabrication standards, and installation procedures. Key requirements include electrolytically deposited zinc-coated steel anchors and accessories meeting ASTM A879/A879M standards, specific wall anchor requirements (minimum three anchors per jamb), and floor anchors drilled for 3/8 inch anchor bolts. The specification requires doors and frames to be strong, rigid, and free from defects, with proper hardware preparation according to SDI/DOOR A250.8 and ANSI/BHMA A156.115 standards. Installation must follow SDI/DOOR A250.11 guidelines, with specific requirements for frame alignment, bracing, and door hanging clearances.

View the file

Other files for this federal contract opportunity

Other files attached to B2424 Dorm Construction Renovations, newest first.
File Type Posted
Solicitation Amendment FA448425R00040004 SF 30.pdf PDF
J12_B2424 Dorm Renovations QA.pdf PDF
J15_Hazmat Report.pdf PDF
C1_Statement of Work V.2.pdf PDF
Solicitation Amendment FA448425R00040003.pdf PDF
J12_B2424 Dorm Renovations QA.pdf PDF
J14_Misc Metal Fabrications.pdf PDF
Solicitation Amendment FA448425R00040002 SF 30.pdf PDF
B2424 Site Visit Sign-in Sheet.pdf PDF
Solicitation - FA448425R00040001.pdf PDF
L1_ Instructions to Offerors.docx DOCX document
Solicitation Amendment FA448425R00040001 SF 30.pdf PDF
J5_Drawings.pdf PDF
Solicitation - FA448425R0004.pdf PDF
Solicitation - FA448425R0004.pdf PDF
J2_ Specification Volume I.pdf PDF
J6_ JBMDL Antiterrorism Awareness for Contractors - Trifold .pdf PDF
J8_ JBMDL Medical Statement for Contractors.docx DOCX document
J5_ Drawings.pdf PDF
J3_ Specification Volume II.pdf PDF
J7_ JBMDL Awareness Guide for Contractors.pdf PDF
J11_ Past Performance Questionnaire .pdf PDF
J4_ Bid Schedule.pdf PDF
J1_ Material Submittal.xlsx XLSX spreadsheet
C1_Statement of Work.pdf PDF
J9_ SFS Contractor Appendix.pdf PDF
M1_ Evaluation Factors for Award.docx DOCX document
L1_ Instructions to Offerors.docx DOCX document
J10_ Wage Determination.txt TXT text file
Show all 29

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SECTION 08 11 13

STEEL DOORS AND FRAMES

08/20

PART 1 GENERAL

1.1 REFERENCES

The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.

AMERICAN WELDING SOCIETY (AWS)

AWS D1.1/D1.1M (2020; Errata 1 2021) Structural Welding

Code - Steel

ASTM INTERNATIONAL (ASTM)

ASTM A653/A653M (2023) Standard Specification for Steel

Sheet, Zinc-Coated (Galvanized) or

Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process

ASTM A879/A879M (2012; R 2017) Standard Specification for

Steel Sheet, zinc Coated by the

Electrolytic Process for Applications

Requiring Designation of the Coating Mass on Each Surface

ASTM A924/A924M (2022a) Standard Specification for General

Requirements for Steel Sheet, Metallic-Coated by the Hot-Dip Process

ASTM C578 (2023) Standard Specification for Rigid, Cellular Polystyrene Thermal Insulation

ASTM C591 (2022) Standard Specification for Unfaced

Preformed Rigid Cellular Polyisocyanurate

Thermal Insulation

ASTM C612 (2014; R 2019) Standard Specification for

Mineral Fiber Block and Board Thermal

Insulation

ASTM D2863 (2019) Standard Test Method for Measuring the Minimum Oxygen Concentration to

Support Candle-Like Combustion of Plastics

(Oxygen Index)

ASTM E1300 (2024) Standard Practice for Determining

Load Resistance of Glass in Buildings

ASTM F2247 (2018) Standard Test Method for Metal

Doors Used in Blast Resistant Applications

(Equivalent Static Load Method)

ASTM F2248 (2012) Standard Practice for Specifying an

Equivalent 3-Second Duration Design

Loading for Blast Resistant Glazing

Fabricated with Laminated Glass

ASTM F2927 (2012) Standard Test Method for Door

Systems Subject to Airblast Loadings

BUILDERS HARDWARE MANUFACTURERS ASSOCIATION (BHMA)

ANSI/BHMA A156.115 (2016) Hardware Preparation in Steel Doors and Steel Frames

NATIONAL ASSOCIATION OF ARCHITECTURAL METAL MANUFACTURERS (NAAMM)

NAAMM HMMA 810 (2009) Hollow Metal Doors

NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)

NFPA 80 (2022) Standard for Fire Doors and Other

Opening Protectives

NFPA 105 (2025) Standard for Smoke Door Assemblies and Other Opening Protectives

NFPA 252 (2022) Standard Methods of Fire Tests of

Door Assemblies

STEEL DOOR INSTITUTE (SDI/DOOR)

SDI/DOOR 111 (2009) Recommended Details for Standard

Steel Doors, Frames, and Accessories and

Related Components

SDI/DOOR 113 (2023) Standard Practice for Determining the Steady-State Thermal Transmittance of

Steel Door and Frame Assemblies

SDI/DOOR A250.3 (2019) Test Procedure and Acceptance

Criteria for Factory Applied Finish

Coatings for Steel Doors and Frames

SDI/DOOR A250.4 (2022) Test Procedure and Acceptance

Criteria for Physical Endurance for Steel

Doors, Frames and Frame Anchors

SDI/DOOR A250.6 (2020) Recommended Practice for Hardware

Reinforcing on Standard Steel Doors and

Frames

SDI/DOOR A250.8 (2023) Specifications for Standard Steel

Doors and Frames

SDI/DOOR A250.11 (2022) Recommended Erection Instructions for Steel Frames

U.S. DEPARTMENT OF DEFENSE (DOD)

UFC 4-010-01 (2018; with Change 3, 2024) DoD Minimum

Antiterrorism Standards for Buildings

UL SOLUTIONS (UL)

UL 10C (2016; Reprint May 2021) UL Standard for

Safety Positive Pressure Fire Tests of

Door Assemblies

1.2 SUBMITTALS

Government approval is required for submittals with a "G" or "S" classification. Submit the following in accordance with Section 01 33 00

SUBMITTAL PROCEDURES:

SD-02 Shop Drawings

Doors; G

Frames; G

Schedule of Doors

Schedule of Frames; G

SD-03 Product Data

Doors; G

Recycled Content for Steel Door Product; S

Frames; G

Recycled Content for Steel Frame Product; S

1.3 DELIVERY, STORAGE, AND HANDLING

Deliver doors, frames, and accessories undamaged and with protective wrappings or packaging. Strap knock-down frames in bundles. Store doors and frames on platforms under cover in clean, dry, ventilated, and accessible locations, with 1/4 inch airspace between doors. Remove damp or wet packaging immediately and wipe affected surfaces dry. Replace damaged materials with new.

PART 2 PRODUCTS

2.1 STANDARD STEEL DOORS

SDI/DOOR A250.8, except as specified otherwise. Prepare doors to receive door hardware as specified in Section 08 71 00 DOOR HARDWARE. Undercut where indicated. Provide exterior doors with top edge closed flush and sealed to prevent water intrusion. Provide doors at 1-3/4 inch thick, unless otherwise indicated. Provide door material that uses a minimum of

25 percent recycled content. Provide data indicating percentage of recycled content for steel door product.

2.1.1 Classification - Level, Performance, Model

2.1.1.1 Standard Duty Doors

SDI/DOOR A250.8, Level 1, physical performance Level C, Model 1, of size(s) and design(s) indicated and core construction as required by the manufacturer. Provide where shown.

2.2 STANDARD STEEL FRAMES

SDI/DOOR A250.8, Level 1, except as otherwise specified. Form frames to sizes and shapes indicated, with knock-down field-assembled corners.

Provide steel frames for doors, unless otherwise indicated. Provide frame product that uses a minimum of 25 percent recycled content. Provide data indicating percentage of recycled content for steel frame product.

2.2.1 Knock-Down Frames

Design corners for simple field assembly by concealed tenons, splice plates, or interlocking joints that produce square, rigid corners and a tight fit and maintain the alignment of adjoining members. Provide locknuts for bolted connections.

2.2.2 Anchors

Provide anchors to secure the frame to adjoining construction. Provide steel anchors, zinc-coated not lighter than 18 gage.

2.2.2.1 Wall Anchors

Provide at least three anchors for each jamb. For frames which are more than 7.5 feet in height, provide one additional anchor for each jamb for each additional 2.5 feet or fraction thereof.

a. Masonry: Provide anchors of corrugated or perforated steel straps or 3/16 inch diameter steel wire, adjustable or T-shaped;

b. Stud partitions: Weld or otherwise securely fasten anchors to backs of frames. Design anchors to be fastened to wood studs with nails, or to closed steel studs with sheet metal screws, and to open steel studs by wiring or welding;

c. Completed openings: Secure frames to previously placed concrete or masonry with expansion bolts in accordance with SDI/DOOR 111;

and

d. Solid plaster partitions: Secure anchors solidly to back of frames and tie into the lath. Provide adjustable top strut anchors on each side of frame for fastening to structural members or ceiling construction above. Provide size and type of strut anchors as recommended by the frame manufacturer.

2.2.2.2 Floor Anchors

Provide floor anchors drilled for 3/8 inch anchor bolts at bottom of each jamb member.

2.3 HARDWARE PREPARATION

Drill and tap doors and frames to receive finish hardware. Prepare doors and frames for hardware in accordance with the applicable requirements of

SDI/DOOR A250.8 and SDI/DOOR A250.6. For additional requirements refer to

ANSI/BHMA A156.115. Drill and tap for surface-applied hardware at the project site. Build additional reinforcing for surface-applied hardware into the door at the factory. Punch door frames to receive a minimum of two rubber or vinyl door silencers on lock side of single doors and one silencer for each leaf at heads of double doors. Set lock strikes out to provide clearance for silencers.

2.4 FINISHES

2.4.1 Electrolytic Zinc-Coated Anchors and Accessories

Provide electrolytically deposited zinc-coated steel in accordance with

ASTM A879/A879M, Commercial Quality, Coating Class A. Phosphate treat and factory prime zinc-coated surfaces as specified in SDI/DOOR A250.8.

2.5 FABRICATION AND WORKMANSHIP

Provide finished doors and frames that are strong and rigid, neat in appearance, and free from defects, waves, scratches, cuts, dents, ridges, holes, warp, and buckle. Provide molded members that are clean cut, straight, and true, with joints coped or mitered, well formed, and in true alignment. Dress exposed welded and soldered joints smooth. Design door frame sections for use with the wall construction indicated. Corner joints must be well formed and in true alignment. Conceal fastenings where practicable.

PART 3 EXECUTION

3.1 INSTALLATION

3.1.1 Frames

Set frames in accordance with SDI/DOOR A250.11. Plumb, align, and brace securely until permanent anchors are set. Anchor bottoms of frames with expansion bolts or powder-actuated fasteners. Build in or secure wall anchors to adjoining construction.]

3.1.2 Doors

Hang doors in accordance with clearances specified in SDI/DOOR A250.8.

After erection and glazing, clean and adjust hardware.

3.2 PROTECTION

Protect doors and frames from damage. Repair damaged doors and frames prior to completion and acceptance of the project or replace with new, as directed. Wire brush rusted frames until rust is removed. Clean thoroughly. Apply an all-over coat of rust-inhibitive paint of the same type used for shop coat.

3.3 CLEANING

Upon completion, clean exposed surfaces of doors and frames thoroughly.

Remove mastic smears and other unsightly marks.

-- End of Section --