J13_Door and Frames Specifications.pdf
PDF 31 KB Posted
- Attached to
- B2424 Dorm Construction Renovations Federal contract opportunity
- Solicitation number
- FA448425R0004
About this file
This is a technical specification document (Section 08 11 13) detailing requirements for steel doors and frames for a dorm renovation project at Joint Base McGuire-Dix-Lakehurst. The specification requires standard steel doors that are 1-3/4 inch thick with a minimum 25% recycled content, and frames must be Level 1 knock-down field-assembled corners with zinc-coated anchors.
The document outlines detailed requirements for door hardware preparation, finishes, fabrication standards, and installation procedures. Key requirements include electrolytically deposited zinc-coated steel anchors and accessories meeting ASTM A879/A879M standards, specific wall anchor requirements (minimum three anchors per jamb), and floor anchors drilled for 3/8 inch anchor bolts. The specification requires doors and frames to be strong, rigid, and free from defects, with proper hardware preparation according to SDI/DOOR A250.8 and ANSI/BHMA A156.115 standards. Installation must follow SDI/DOOR A250.11 guidelines, with specific requirements for frame alignment, bracing, and door hanging clearances.
View the file
Other files for this federal contract opportunity
Show all 29
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SECTION 08 11 13
STEEL DOORS AND FRAMES
08/20
PART 1 GENERAL
1.1 REFERENCES
The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.
AMERICAN WELDING SOCIETY (AWS)
AWS D1.1/D1.1M (2020; Errata 1 2021) Structural Welding
Code - Steel
ASTM INTERNATIONAL (ASTM)
ASTM A653/A653M (2023) Standard Specification for Steel
Sheet, Zinc-Coated (Galvanized) or
Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process
ASTM A879/A879M (2012; R 2017) Standard Specification for
Steel Sheet, zinc Coated by the
Electrolytic Process for Applications
Requiring Designation of the Coating Mass on Each Surface
ASTM A924/A924M (2022a) Standard Specification for General
Requirements for Steel Sheet, Metallic-Coated by the Hot-Dip Process
ASTM C578 (2023) Standard Specification for Rigid, Cellular Polystyrene Thermal Insulation
ASTM C591 (2022) Standard Specification for Unfaced
Preformed Rigid Cellular Polyisocyanurate
Thermal Insulation
ASTM C612 (2014; R 2019) Standard Specification for
Mineral Fiber Block and Board Thermal
Insulation
ASTM D2863 (2019) Standard Test Method for Measuring the Minimum Oxygen Concentration to
Support Candle-Like Combustion of Plastics
(Oxygen Index)
ASTM E1300 (2024) Standard Practice for Determining
Load Resistance of Glass in Buildings
ASTM F2247 (2018) Standard Test Method for Metal
Doors Used in Blast Resistant Applications
(Equivalent Static Load Method)
ASTM F2248 (2012) Standard Practice for Specifying an
Equivalent 3-Second Duration Design
Loading for Blast Resistant Glazing
Fabricated with Laminated Glass
ASTM F2927 (2012) Standard Test Method for Door
Systems Subject to Airblast Loadings
BUILDERS HARDWARE MANUFACTURERS ASSOCIATION (BHMA)
ANSI/BHMA A156.115 (2016) Hardware Preparation in Steel Doors and Steel Frames
NATIONAL ASSOCIATION OF ARCHITECTURAL METAL MANUFACTURERS (NAAMM)
NAAMM HMMA 810 (2009) Hollow Metal Doors
NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)
NFPA 80 (2022) Standard for Fire Doors and Other
Opening Protectives
NFPA 105 (2025) Standard for Smoke Door Assemblies and Other Opening Protectives
NFPA 252 (2022) Standard Methods of Fire Tests of
Door Assemblies
STEEL DOOR INSTITUTE (SDI/DOOR)
SDI/DOOR 111 (2009) Recommended Details for Standard
Steel Doors, Frames, and Accessories and
Related Components
SDI/DOOR 113 (2023) Standard Practice for Determining the Steady-State Thermal Transmittance of
Steel Door and Frame Assemblies
SDI/DOOR A250.3 (2019) Test Procedure and Acceptance
Criteria for Factory Applied Finish
Coatings for Steel Doors and Frames
SDI/DOOR A250.4 (2022) Test Procedure and Acceptance
Criteria for Physical Endurance for Steel
Doors, Frames and Frame Anchors
SDI/DOOR A250.6 (2020) Recommended Practice for Hardware
Reinforcing on Standard Steel Doors and
Frames
SDI/DOOR A250.8 (2023) Specifications for Standard Steel
Doors and Frames
SDI/DOOR A250.11 (2022) Recommended Erection Instructions for Steel Frames
U.S. DEPARTMENT OF DEFENSE (DOD)
UFC 4-010-01 (2018; with Change 3, 2024) DoD Minimum
Antiterrorism Standards for Buildings
UL SOLUTIONS (UL)
UL 10C (2016; Reprint May 2021) UL Standard for
Safety Positive Pressure Fire Tests of
Door Assemblies
1.2 SUBMITTALS
Government approval is required for submittals with a "G" or "S" classification. Submit the following in accordance with Section 01 33 00
SUBMITTAL PROCEDURES:
SD-02 Shop Drawings
Doors; G
Frames; G
Schedule of Doors
Schedule of Frames; G
SD-03 Product Data
Doors; G
Recycled Content for Steel Door Product; S
Frames; G
Recycled Content for Steel Frame Product; S
1.3 DELIVERY, STORAGE, AND HANDLING
Deliver doors, frames, and accessories undamaged and with protective wrappings or packaging. Strap knock-down frames in bundles. Store doors and frames on platforms under cover in clean, dry, ventilated, and accessible locations, with 1/4 inch airspace between doors. Remove damp or wet packaging immediately and wipe affected surfaces dry. Replace damaged materials with new.
PART 2 PRODUCTS
2.1 STANDARD STEEL DOORS
SDI/DOOR A250.8, except as specified otherwise. Prepare doors to receive door hardware as specified in Section 08 71 00 DOOR HARDWARE. Undercut where indicated. Provide exterior doors with top edge closed flush and sealed to prevent water intrusion. Provide doors at 1-3/4 inch thick, unless otherwise indicated. Provide door material that uses a minimum of
25 percent recycled content. Provide data indicating percentage of recycled content for steel door product.
2.1.1 Classification - Level, Performance, Model
2.1.1.1 Standard Duty Doors
SDI/DOOR A250.8, Level 1, physical performance Level C, Model 1, of size(s) and design(s) indicated and core construction as required by the manufacturer. Provide where shown.
2.2 STANDARD STEEL FRAMES
SDI/DOOR A250.8, Level 1, except as otherwise specified. Form frames to sizes and shapes indicated, with knock-down field-assembled corners.
Provide steel frames for doors, unless otherwise indicated. Provide frame product that uses a minimum of 25 percent recycled content. Provide data indicating percentage of recycled content for steel frame product.
2.2.1 Knock-Down Frames
Design corners for simple field assembly by concealed tenons, splice plates, or interlocking joints that produce square, rigid corners and a tight fit and maintain the alignment of adjoining members. Provide locknuts for bolted connections.
2.2.2 Anchors
Provide anchors to secure the frame to adjoining construction. Provide steel anchors, zinc-coated not lighter than 18 gage.
2.2.2.1 Wall Anchors
Provide at least three anchors for each jamb. For frames which are more than 7.5 feet in height, provide one additional anchor for each jamb for each additional 2.5 feet or fraction thereof.
a. Masonry: Provide anchors of corrugated or perforated steel straps or 3/16 inch diameter steel wire, adjustable or T-shaped;
b. Stud partitions: Weld or otherwise securely fasten anchors to backs of frames. Design anchors to be fastened to wood studs with nails, or to closed steel studs with sheet metal screws, and to open steel studs by wiring or welding;
c. Completed openings: Secure frames to previously placed concrete or masonry with expansion bolts in accordance with SDI/DOOR 111;
and
d. Solid plaster partitions: Secure anchors solidly to back of frames and tie into the lath. Provide adjustable top strut anchors on each side of frame for fastening to structural members or ceiling construction above. Provide size and type of strut anchors as recommended by the frame manufacturer.
2.2.2.2 Floor Anchors
Provide floor anchors drilled for 3/8 inch anchor bolts at bottom of each jamb member.
2.3 HARDWARE PREPARATION
Drill and tap doors and frames to receive finish hardware. Prepare doors and frames for hardware in accordance with the applicable requirements of
SDI/DOOR A250.8 and SDI/DOOR A250.6. For additional requirements refer to
ANSI/BHMA A156.115. Drill and tap for surface-applied hardware at the project site. Build additional reinforcing for surface-applied hardware into the door at the factory. Punch door frames to receive a minimum of two rubber or vinyl door silencers on lock side of single doors and one silencer for each leaf at heads of double doors. Set lock strikes out to provide clearance for silencers.
2.4 FINISHES
2.4.1 Electrolytic Zinc-Coated Anchors and Accessories
Provide electrolytically deposited zinc-coated steel in accordance with
ASTM A879/A879M, Commercial Quality, Coating Class A. Phosphate treat and factory prime zinc-coated surfaces as specified in SDI/DOOR A250.8.
2.5 FABRICATION AND WORKMANSHIP
Provide finished doors and frames that are strong and rigid, neat in appearance, and free from defects, waves, scratches, cuts, dents, ridges, holes, warp, and buckle. Provide molded members that are clean cut, straight, and true, with joints coped or mitered, well formed, and in true alignment. Dress exposed welded and soldered joints smooth. Design door frame sections for use with the wall construction indicated. Corner joints must be well formed and in true alignment. Conceal fastenings where practicable.
PART 3 EXECUTION
3.1 INSTALLATION
3.1.1 Frames
Set frames in accordance with SDI/DOOR A250.11. Plumb, align, and brace securely until permanent anchors are set. Anchor bottoms of frames with expansion bolts or powder-actuated fasteners. Build in or secure wall anchors to adjoining construction.]
3.1.2 Doors
Hang doors in accordance with clearances specified in SDI/DOOR A250.8.
After erection and glazing, clean and adjust hardware.
3.2 PROTECTION
Protect doors and frames from damage. Repair damaged doors and frames prior to completion and acceptance of the project or replace with new, as directed. Wire brush rusted frames until rust is removed. Clean thoroughly. Apply an all-over coat of rust-inhibitive paint of the same type used for shop coat.
3.3 CLEANING
Upon completion, clean exposed surfaces of doors and frames thoroughly.
Remove mastic smears and other unsightly marks.
-- End of Section --