TECHNICAL_EXHIBIT_06_CONFINED_SPACE_LOCATIONS.pdf

PDF 81 KB Posted

Attached to
Tertiary Wastewater Treatment Facility at Joint Base McGuire-Dix-Lakehurst (JB-MDL), NJ
Solicitation number
FA4484-17-R-0006
Issued by

About this file

Technical Exhibit 06 ~ Confined Space Locations

View the file

Other files

File Type Posted
JB_MDL_FA4484-17-R-0006-0004.docx.pdf PDF
JB_MDL_FA4484-17-R-0006-0003.pdf PDF
JB_MDL_New_Collective_Bargaining_Agreement.pdf PDF
JB-MDL_Technical_Exhibit_07_Revision_01.pdf PDF
JB-MDL_FA4484-17-R-0006-0002.pdf PDF
JB-MDL_PERFORMANCE_WORK_STATEMENT_20170721_(Rev_1).pdf PDF
FA4484-17-R-0006_Amendment_0001.pdf PDF
Wage_Determination_2015-4191_(Rev_2).pdf PDF
TECHNICAL_EXHIBIT_01_CDRL.pdf PDF
TECHNICAL_EXHIBIT_07_FIRE_EXTINGUISHER_COUNT_AND_LOCATION.pdf PDF
A7_Antiterrorism_Awareness_Guide_for_Contractors,_MAR_16.pdf PDF
A2_QUESTIONNAIRE.docx DOCX document
A4_PERFORMANCE_WORK_STATEMENT_20170320.pdf PDF
TECHNICAL_EXHIBIT_03-1_NJPDES_FINAL_TTBS.pdf PDF
A9_Wage_Determination_2015-4191.docx DOCX document
TECHNICAL_EXHIBIT_03-3_Plant_Permit_03012016thru02282021.pdf PDF
A5_JB-MDL_Security_Forces_Appendix_20150610.PDF PDF
A1_QUESTIONNAIRE_COVER_LETTER.pdf PDF
TECHNICAL_EXHIBIT_04_GENERATOR_INVENTORY_AND_MAINTENANCE_ACTION.pdf PDF
JB-MDL_FA4484-17-R-0006__20170706.docx.pdf PDF
A8_Collective_Bargaining_Agreement.pdf PDF
A3_QASP_TWTP.pdf PDF
TECHNICAL_EXHIBIT_03-2_Pinelands_Beneficial_Reuse_Permit.pdf PDF
TECHNICAL_EXHIBIT_02_Security_Requirements.pdf PDF
TECHNICAL_EXHIBIT_05_TTBSS_PDF_Drawings.pdf PDF
A6_JB_MDL_Antiterrorism_Awareness_for_Contractors_(Trifold).pdf PDF
Show all 26

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

TECHNICAL EXHIBIT # 06

CONFINED SPACE LOCATIONS

BUILDING

Number

TYPE OF LOCATION TYPE ACCESS

PERMIT

REQUIRED

0199 LIFT STATION, SEWER PIT‐WET WELL PLATE 24"X48" YES

0199 LIFT STATION, SEWER PIT‐GRINDER CHAMBER GRATES YES

1803 LIFT STATION, SEWER PIT‐WET WELL HATCH 4'X4' YES

1803 LIFT STATION, SEWER PIT‐GRINDER CHAMBER GRATES YES

202 LIFT STATION, SEWER PIT‐WET WELL

BILCO DOOR LESS

THAN 36'

DIAMETER YES

3155 LIFT STATION, SEWER PIT‐WET WELL HATCH 4'X4' YES

3155 LIFT STATION, PIT VALVE CHAMBER PLATE 30"X30" YES

3155 LIFT STATION, RAG BASKET CHAMBER HATCH 30"X30" YES

4301 LIFT STATION, SEWER PIT‐WET WELL HATCH 30"X30" YES

4301 LIFT STATION, SEWER PIT‐WET WELL GRATES YES

4310 LIFT STATION, SEWER PIT‐GRINDER CHAMBER HATCH 36"X30" YES

4353 PIT, WET WELL LARGE PLATES YES

4399 SEWER LIFT PUMP YES

500 LIFT STATION, SEWER PIT‐WET WELL

BILCO DOOR LESS

THAN 36'

DIAMETER YES

5324 PIT, WASTEWATER PUMP OPEN TOP 8'X14' YES

5426 SANITARY SEWER

MANHOLE 24"

DIAMETER YES

5727 LIFT STATION, SEWER PIT‐WET WELL

MANHOLE 24"

DIAMETER YES

5757 LIFT STATION, SEWER PIT‐GRINDER CHAMBER

HATCH DOORS

3'X4' ‐ 2EA YES

5860 LIFT STATION, SEWER PIT‐GRINDER CHAMBER GRATES YES

5860 LIFT STATION, SEWER PIT‐WET WELL HATCH 30"X30" YES

5998 LIFT STATION, SEWER PIT‐WET WELL

BILCO DOOR LESS

THAN 36'

DIAMETER YES

5998 LIFT STATION, PIT VALVE CHAMBER PLATE 30"X30" YES

5998 LIFT STATION, RAG BASKET CHAMBER HATCH 30"X30" YES

5999 LIFT STATION, SEWER PIT‐WET WELL HATCH 30"X30" YES

File details come from the government source that posted it. Updated .