HVAC List - Appendix (with B91012 Added).xlsx
XLSX spreadsheet 39 KB Posted
- Attached to
- HVAC Preventive Maintenance Federal contract opportunity
- Solicitation number
- FA441724Q0150
About this file
This document is a federal contract opportunity for HVAC Preventive Maintenance Services at Hurlburt Field, FL. The 1st Special Operations Contracting Squadron intends to award a single contract with a base period of one year and four one-year option periods. The work includes all management, labor, tools, supplies, equipment, supervision, materials, and transportation necessary to provide complete preventive maintenance services for the HVAC systems. This is a small business set-aside with NAICS code 238220 and a $19 million size standard. The solicitation will be available on SAM.gov, and proposals will be accepted from all responsible sources. Key details include the performance period, scope of work, set-aside, and contracting point of contacts.
View the file
Other files for this federal contract opportunity
Show all 16
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FSS
| Facility | Organization |
| 90213 | 1 SO FORCE SUPP SQ |
| 90220 | 1 SO FORCE SUPP SQ |
| 90228 | 1 SO FORCE SUPP SQ |
| 90229 | 1 SO FORCE SUPP SQ |
| 90230 | 1 SO FORCE SUPP SQ |
| 90231 | 1 SO FORCE SUPP SQ |
| 90232 | 1 SO FORCE SUPP SQ |
| 90300 | 1 SO FORCE SUPP SQ |
| 90306 | 1 SO FORCE SUPP SQ |
| 90327 | 1 SO FORCE SUPP SQ |
| 90337 | 1 SO FORCE SUPP SQ |
| 90353 | 1 SO FORCE SUPP SQ |
| 90357 | 1 SO FORCE SUPP SQ |
| 90359 | 1 SO FORCE SUPP SQ |
| 90502 | 1 SO FORCE SUPP SQ |
| 90507 | 1 SO FORCE SUPP SQ |
| 90509 | 1 SO FORCE SUPP SQ |
| 90517 | 1 SO FORCE SUPP SQ |
| 90642 | 1 SO FORCE SUPP SQ |
| 90918 | 1 SO FORCE SUPP SQ |
| 91007 | 1 SO FORCE SUPP SQ |
| 91168 | 1 SO FORCE SUPP SQ |
| 92473 | 1 SO FORCE SUPP SQ |
| 92485 | 1 SO FORCE SUPP SQ |
| 93261 | 1 SO FORCE SUPP SQ |
Parts
| BELTS | SET 1 | SET 2 | MOTOR INFO | |||||||||||||
| FACILITY | NAME | AHU | LOCATION | SIZE | QTY | FILTER | QTY2 | FILTER | QTY3 | # AHU's | HP | VOLTS | FRAME | PHASE | RPM | NOTES |
| 90213 | Family Support | 1 | B 60 | 2 | 16x20x2 | 24 | 1 | 10 | 200 | S215T | 3 | 1750 | ||||
| 90220 | Education Center | 1 | West-Side Exterior Mech Room | B 62 | 2 | 16x25x2 | 12 | 10 | 200-208 | S215T | 3 | 1750 | ||||
| 90220 | Education Center | 5 | Comm Side Ext Mech Room | Direct-Drive | 24x24x2 | 12 | 5 | 200-208 | S184T | 3 | 1745 | |||||
| 90220 | Education Center | 6 | New Edition Westside Ext. Mech RM | A 52 | 1 | 20x25x2 | 3 | 1.5 | 208 | |||||||
| 90220 | Education Center | 7 | Server Room East Side | Direct-Drive | 20x20x2 | 1 | 4 | |||||||||
| 90228 | Mini Mall | 1 | On top of North end of post office | A 60 | 1 | 16x25x2 | 4 | 20X20X2 | 3 | |||||||
| 90228 | Mini Mall | 2 | Above Post Office | A 32 | 1 | 16x25x2 | 4 | |||||||||
| 90228 | Mini Mall | 3 | Center of Roof | A 39 | 1 | 16x16x2 | 2 | |||||||||
| 90228 | Mini Mall | 4 | On top of Church's Chicken | B 81 | 1 | 20x25x2 | 4 | 20x20x2 | 4 | |||||||
| 90228 | Mini Mall | 5 | Above Starbucks | A 46 | 1 | 16x25x2 | 2 | |||||||||
| 90228 | Mini Mall | 6 | Above Food Court (large Unit) | B 81 | 1 | 20x25x2 | 4 | 20x20x2 | 4 | 6 | ||||||
| 90229 | Commando Store | 1 | Backside Mech Room | B 36 | 2 | 24x24x2 | 2 | 12x24x2 | 1 | 7.5 | 200 | 213T | 3 | 1725 | ||
| 90229 | Commando Store | 2 | Backside Mech Room | B 35 | 1 | 24x24x2 | 2 | 3 | 200 | 182T | 3 | 1780 | Magnetek | |||
| 90229 | Commando Store | EX Fan | Backside Mech Room | A 39 | 1 | 3 | ||||||||||
| 90230 | Theater | 1 | Exterior South Mech Rm | B 40 | 1 | 20x20x2 | 6 | 5 | 200 | S184T | 3 | 1745 | ||||
| 90230 | Theater | 2 | Exterior West Inside Enclosure | A 53 | 1 | 16x25x1 | 4 | 3 | 20-230/460 | 3 | 1725 | |||||
| 90230 | Theater | 3 | 2nd Floor Interior | 18x24x1 | 1 | 3 | ||||||||||
| 90231 | Bowling Alley | 1 | Exterior East Mech Rm | A 43 | 1 | 16x20x2 | 8 | 2 | 208-230/460 | 145T | 3 | 1725 | ||||
| 90231 | Bowling Alley | 2 | Interior South Mech Rm | B 83 | 1 | 20x25x2 | 12 | 10 | 230/460 | S215T | 3 | 1760 | ||||
| 90231 | Bowling Alley | 2 | Return Air fan for AHU 2 | B 75 | 2 | 2 | ||||||||||
| 90232 | HAWC | 1 | 2nd Flr Right Mech Rm (left Unit) | B 34 | 2 | 20X20X2 | 3 | 12X24X2 | 2 | 5 | 200 | A184T | 3 | 1745 | ||
| 90232 | HAWC | 2 | 2nd Flr Right Mech Rm (right Unit) | B 38 | 2 | 20X24X2 | 3 | 12X24X2 | 2 | 5 | 200 | A184T | 3 | 1745 | ||
| 90232 | HAWC | 3 | 2nd Flr Right Mech Rm (center Unit) | B 34 | 2 | 20x24x2 | 3 | 5 | 200 | A184T | 3 | 1445 | ||||
| 90232 | HAWC | 4 | 2nd Flr Left Mech Rm | A 38 | 1 | 16X25X2 | 2 | |||||||||
| 90232 | HAWC | 5 | 2nd Flr Left Mech Rm | A 38 | 1 | 16X25X2 | 2 | |||||||||
| 90232 | HAWC | 6 | Exterior East Mech Rm | B 42 | 2 | 18x24x2 | 3 | 5 | 200 | 184T | 3 | 1740 | ||||
| 90232 | HAWC | 7 | Package Unit Outside | B 90 | 1 | 20x20x2 | 12 | 3 | 208-230/460 | 3 | 1725 | |||||
| 90232 | HAWC | 1 | Right EX Fan Up stairs | A 50 | 1 | |||||||||||
| 90232 | HAWC | 2 | Center EX Fan Up stairs | A 43 | 1 | |||||||||||
| 90232 | HAWC | 3 | Left EX Fan Up stairs | A 40 | 1 | 7 | ||||||||||
| 90300 | Base Pool | 2 | Storage Room | Direct-Drive | 24X24X4 | 1 | 2 | Marathon Electric | ||||||||
| 90306 | New CDC West | 1 | Front Mech Rm | B 49 | 2 | 16x20x2 | 5 | 20x24x2 | 4 | 15 | 230/460 | 254T | 3 | 1765 | Magnetek | |
| 90306 | New CDC West | 2 | Front Mech Rm | A 38 | 1 | 16x20x2 | 2 | 2.3 | 230/460 | 182T | 3 | 1760 | Marathon Electric | |||
| 90306 | New CDC West | ERV | Front Mech Rm | A 46 | 1 | 16x20x2 | 4 | 14x25x2 | 1 | 2 | 208-230/460 | E143-5T | 3 | 1730 | Baldor Super-E Motor | |
| 90306 | New CDC West | ERV | Back Panel of ERV | A 51 | 1 | 16x20x2 | 4 | 14x25x2 | 1 | 4 | 2.2 | 230/460 | 182T | 3 | 1755 | |
| 90327 | FSS Command | 1 | Back of bld | B 50 | 2 | 20x20x2 | 3 | 20x24x2 | 3 | 1 | 15 | 200 | 254T | 3 | 1760 | Carrier 99MR0627B4270103 |
| 90337 | Library | 1 | Rooftop | B 60 | 2 | 16x25x2 | 15 | 16x20x2 | 5 | McQuay | ||||||
| 90337 | Library | 2 | Outside | B 74 | 1 | 16x25x2 | 1 | 16x20x2 | 9 | 5 | 208-230/460 | 184T | 3 | 1740 | ||
| 90337 | Library | 3 | Direct-Drive | 16x24x2 | 3 | |||||||||||
| 90337 | Library | Air Comp | Mech RM | A 48 | 2 | Blow Down | Oil | 3 | ||||||||
| 90353 | CDC | 1 | Right Side of Building | B 68 | 1 | 16x25x2 | 6 | 5 | 200 | A184T | 3 | 1725 | ||||
| 90353 | CDC | 2 | on the Back of the Building | B 64 | 2 | 16x20x2 | 6 | 2 | 6 | 230/460 | 184T | 3 | 1760 | |||
| 90357 | CDC | 1 | Mech room | B 74 | 1 | 16x20x2 | 8 | |||||||||
| 90357 | CDC | ROOM 18 door | N/A | 20X20X1 | 1 | |||||||||||
| 90357 | CDC | ROOM 20 door | N/A | 20X20X1 | 1 | |||||||||||
| 90357 | CDC | ROOM 20 door | N/A | 18X18X1 | 1 | |||||||||||
| 90357 | CDC | ROOM 19 door | N/A | 24X24X1 | 1 | 5 | ||||||||||
| 90359 | HG BLDG | 1 | SOUTH AHU | 20x20x1 | 2 | 1 | ||||||||||
| 90502 | Visiting QTR | 1 | 3rd FL Mech RM | B 81 | 3 | 20x25x4 | 15 | 16x20x4 | 6 | 30 | 200 | 286T | 3 | 1760 | ||
| 90502 | Visiting QTR | 2nd floor new side | A 36 / A 40 | 1 | 20x20x2 | 2 | 20x20x4 | 2 | 2 | |||||||
| 90507 | Visiting QTR | 1 | First Floor | Direct Drive | 1 | 24x24x2 | 2 | 7.5 | 208-230/460 | S213T | 3 | 1760 | ||||
| 90507 | Visiting QTR | 2 | Second Floor | B 42 | 1 | 24x24x2 | 2 | 2 | 7.5 | 208-230/460 | S213T | 3 | 1760 | |||
| 90509 | Commando INN | 1 | Backside Mech Room | B 42 | 2 | 15X20X2 | 8 | 7.5 | 230/460 | S213T | 3 | 1745 | ||||
| 90509 | Commando INN | 2 | Side exterior mech room | A 47 | 1 | 16X25X1 | 3 | |||||||||
| 90509 | Commando INN | Marathon Electric | ||||||||||||||
| 90509 | Commando INN | 4 | Child Care side back interior | Direct-Drive | 20x20x1 | 1 | 3 | |||||||||
| 90517 | Aderholt | 1 | Back Mech Room | A 48 | 2 | 24X24X2 | 9 | |||||||||
| 90517 | Aderholt | 2 | Back Mech Room | B 42 | 2 | 24X24X2 | 9 | |||||||||
| 90517 | Aderholt | 3 | Inside Mech Room | A 30 | 2 | 24X24X2 | 4 | |||||||||
| 90517 | Aderholt | 4 | Back Outside AHU | B 96 | 1 | 20X20X2 | 12 | |||||||||
| 90517 | Aderholt | 5 | New Unit for Weight Room | A 48 | 1 | 16x25x1 | 2 | 14x25x1 | 1 | |||||||
| 90517 | Aderholt | EX fan | Main Mech rm above AHU Ex fan | A 43 | 1 | 5 | ||||||||||
| 90642 | 1 | Exterior East Mech Rm | Direct-Drive | 16x25x1 | 1 | |||||||||||
| 90642 | 2 | Direct-Drive | 14x25x1 | 1 | ||||||||||||
| 90642 | return air vent inside door | 16x25x1 | 1 | 2 | ||||||||||||
| 91007 | Riptide Gym/DFAC | 1 | OSA Filter | 14x30x2 | 2 | 10 | 230/460 | S215T | 3 | 1760 | ||||||
| 91007 | Riptide Gym/DFAC | 1 | Main Mech Room | B 52 | 2 | 24x24x2 | 6 | 20 | 200-230/460 | S256T | 3 | 1745 | ||||
| 91007 | Riptide Gym/DFAC | 2 | Upstairs Mech Rm Left Side | A 61 | 4 | 24x24x2 | 6 | 25 | 200-230/460 | S284T | 3 | 1740 | ||||
| 91007 | Riptide Gym/DFAC | 3 | Upstairs Mech Rm Back Side | B 60 | 3 | 24x24x2 | 6 | 20x24x2 | 2 | |||||||
| 91007 | Riptide Gym/DFAC | KEF-1 | Rooftop Exhaust Fan (round) Large | A 53 | 2 | |||||||||||
| 91007 | Riptide Gym/DFAC | KSF-1 | Rooftop Fresh Air Fan (square) | A 51 | 2 | |||||||||||
| 91007 | Riptide Gym/DFAC | Rooftop Exhaust Fan (round) Small | 3L220 | 1 | 10 | 200 | S215T | 3 | 1766 | |||||||
| 90918 | SoundSide | 1 | 1st FL Mech. RM | BX 79 | 3 | 16X20X4 | 36 | 20X20X4 | 6 | |||||||
| 90918 | SoundSide | 2 | 1st FL Mech. RM | A 33 | 1 | 20X20X4 | 6 | |||||||||
| 90918 | SoundSide | 3 | 2nd FL Mech. RM | A 41 | 1 | 16X20X4 | 12 | |||||||||
| 90918 | SoundSide | 4 | Kitchen | Direct-Drive | Washable | 3 | 3 | |||||||||
| 91168 | CDC East | 1 | Front right mech rm | B 52 | 1 | 16x25x2 | 4 | 16x20x2 | 8 | |||||||
| 91168 | CDC East | 2 | Front right mech rm | B 62 | 1 | 16x25x2 | 12 | |||||||||
| 91168 | CDC East | ERAHU | Front right mech rm | A 50 | 2 | 20x20x2 | 6 | 16x20x2 | 6 | |||||||
| 91168 | CDC East | 3 | Front left mech rm | A 40 | 1 | 16x20x2 | 4 | |||||||||
| 91168 | CDC East | 4 | Front left mech rm | A 43 | 1 | 20x25x2 | 4 | 5 | ||||||||
| 92473 | Base Marina | 1 | East Side Mech RM | A 47 | 1 | 16x25x1 | 3 | 1 | ||||||||
| 93261 | Fam Camp | 1 | inside office | direct drive | 16x24x1 | 1 | 1 | |||||||||
| 90359 | HG BLDG | 2 | AHU back wall | 16X20X1 | 1 | 1 | ||||||||||
| 90229 | Welcom Cent | 3 | North Mech Room/inside resiliency center | A 38 | 1 | 24x24x1 | 2 | 18x18x1 | 1 | 1 | ||||||
| 90300 | Base Pool | 2 | Storage RM Outside | Direct-Drive | 16X20X1 | 1 | 2 | |||||||||
| 92485 | Marina Maint | Boat House Heater | A38 | 1 | ||||||||||||
| 91012 | BX | RTU-1 | Rooftop RTU-1 | BX81 | 1 | 20x20x2 | 4 | 20x25x2 | 4 | |||||||
| 91012 | BX | RTU-2 | Rooftop RTU-2 | AX35 | 1 | 20x25x2 | 4 | |||||||||
| 91012 | BX | RTU-3 | Rooftop RTU-3 | BX81 | 1 | 20x20x2 | 4 | 20x25x2 | 4 | |||||||
| 91012 | BX | RTU-4 | Rooftop RTU-4 | BX81 | 1 | 20x20x2 | 4 | 20x25x2 | 4 | |||||||
| 91012 | BX | RTU-5 | Rooftop RTU-5 | BX81 | 1 | 20x20x2 | 4 | 20x25x2 | 4 | |||||||
| 91012 | BX | RTU-6 | Rooftop RTU-6 | BX81 | 1 | 20x20x2 | 4 | 20x25x2 | 4 | |||||||
| 91012 | BX | RTU-7 | Rooftop RTU-7 | BX81 | 1 | 20x20x2 | 4 | 20x25x2 | 4 | |||||||
| 91012 | BX | RTU-8 | Rooftop RTU-8 | BX81 | 1 | 20x20x2 | 4 | 20x25x2 | 4 | |||||||
| 91012 | BX | RTU-9 | Rooftop RTU-9 | BX81 | 1 | 20x25x2 | 4 | 20x25x2 | 4 | |||||||
| 91012 | BX | RTU-10 | Rooftop RTU-10 | AX35 | 1 | 20x30x2 | 4 | |||||||||
| 91012 | BX | RTU-11 | Rooftop RTU-11 | AX26 | 1 | 20x30x2 | 2 | |||||||||
| 91012 | BX | RTU-12 | Rooftop RTU-12 | AX26 | 1 | 20x25x2 | 2 | |||||||||
| 91012 | BX | RTU-13 | Rooftop RTU-13 | AX35 | 1 | 20x20x2 | 4 | |||||||||
| 91012 | BX | RTU-14 | Rooftop RTU-14 | BX68 | 1 | 20x20x2 | 8 | 16x20x2 | 4 | |||||||
| 91012 | BX | RTU-15 | Rooftop RTU-15 | BX68 | 1 | 20x20x2 | 8 | 16x20x2 | 4 | |||||||
| 91012 | BX | RTU-16 | Rooftop RTU-16 | AX29 | 1 | 20x25x2 | 4 | |||||||||
| 91012 | BX | RTU-17 | Rooftop RTU-17 | BX71 | 1 | 20x25x2 | 4 | 20X20X2 | 4 |
Dorms
| Facility | Organization |
| 90323 | BASE DORMITORIES |
| 90352 | BASE DORMITORIES |
| 90358 | BASE DORMITORIES |
| 90367 | BASE DORMITORIES |
| 90368 | BASE DORMITORIES |
| 90369 | BASE DORMITORIES |
| 91009 | BASE DORMITORIES |
| 91053 | BASE DORMITORIES |
| 91054 | BASE DORMITORIES |
| 91055 | BASE DORMITORIES |
| 91056 | BASE DORMITORIES |
Parts2
| BELTS | SET 1 | SET 2 | MOTOR INFO | ||||||||||||
| FACILITY | NAME | AHU | LOCATION | SIZE | QTY | FILTER | QTY2 | FILTER (2) | QTY3 | HP | VOLTS | FRAME | PHASE | RPM | NOTES |
| 90323 | STTP BLDG | 1 | 1st Floor Mech Room | A 39 | 2 | 12x24x4 | 3 | 24x24x4 | 3 | 3 | 200 | 182T | 3 | 1730 | |
| 90323 | STTP BLDG | 2 | 2nd Floor Mech Room | A 39 | 2 | 12x24x4 | 3 | 24x24x4 | 3 | 3 | 200 | 182T | 3 | 1730 | |
| 90323 | STTP BLDG | 3 | 3rd Floor Mech Room | A 39 | 2 | 12x24x4 | 3 | 24x24x4 | 3 | 5 | 200 | 184T | 3 | 1740 | |
| 90352 | 1st floor | B 53 | 1 | 24X24X2 | 2 | 12X24X2 | 2 | ||||||||
| 90352 | 2 floor Mech Room | B 36 | 1 | 20x24x2 | 3 | 12x20x2 | 3 | 7.5 | 200-208 | S213T | 3 | 1745 | |||
| 90352 | 3rd Floor Mech Room | B 35 | 1 | 20x24x2 | 3 | 12x20x2 | 3 | 7.5 | 200-208 | S213T | 3 | 1745 | |||
| 90352 | Boiler Room | A 43 | 1 | 20x24x2 | 1 | 1.5 | 200-230/460 | M145T | 3 | 1745 | |||||
| 90352 | Main Floor Mech Room | A 47 | 1 | 16x20x2 | 2 | 1.5 | 200-230/460 | M145T | 3 | 1745 | |||||
| 90358 | Dorm | 1 | 1st Floor Mech Room A-Wing | B 35 | 1 | 18x24x2 | 1 | 20x24x2 | 2 | 7.5 | 200 | S215T | 3 | 1760 | |
| 90358 | Dorm | O/A Fan-1 | O/A Fan attached to AHU 1 | A 38 | 1 | 1/6 | 115 | 1 | 1725 | ||||||
| 90358 | Dorm | 2 | 2nd Floor Mech Room A-Wing | B 36 | 1 | 18x24x2 | 1 | 20x24x2 | 2 | 7.5 | 200 | S215T | 3 | 1760 | |
| 90358 | Dorm | O/A Fan-2 | O/A Fan attached to AHU 2 | A 38 | 1 | 1/6 | 115 | 1 | 1725 | ||||||
| 90358 | Dorm | 3 | 3rd Floor Mech Room A-Wing | B 60 | 1 | 18x24x2 | 2 | 24x24x2 | 1 | 10 | 200 | S215T | 3 | 1760 | |
| 90358 | Dorm | O/A Fan 3 | O/A Fan Attached to AHU 3 | A 38 | 1 | 1/6 | 115 | 1 | 1725 | ||||||
| 90358 | Dorm | 4 | 1st Floor Mech Room B-Wing | B 35 | 1 | 18x24x2 | 1 | 20x24x2 | 2 | 7.5 | 200 | S215T | 3 | 1760 | |
| 90358 | Dorm | O/A Fan 4 | O/A Fan attached to AHU 4 | A 38 | 1 | 1/6 | 115 | 1 | 1725 | ||||||
| 90358 | Dorm | 5 | 2nd Floor Mech Room B-Wing | B 35 | 1 | 18x24x2 | 1 | 20x24x2 | 2 | 7.5 | 200 | S215T | 3 | 1760 | |
| 90358 | Dorm | O/A Fan 5 | O/A Fan attached to AHU 5 | A 38 | 1 | 1/6 | 115 | 1 | 1725 | ||||||
| 90358 | Dorm | 6 | 3rd Floor Mech Room B-Wing | B 35 | 1 | 18x24x2 | 2 | 20x24x2 | 1 | 10 | 200 | S215T | 3 | 1760 | |
| 90358 | Dorm | O/A Fan 6 | O/A Fan attached to AHU 6 | A 38 | 1 | 1/6 | 115 | 1 | 1725 | ||||||
| 90358 | Dorm | 7 | Day Room and Mail Boxes | B 53 | 1 | 20x24x2 | 2 | 3 | |||||||
| 90358 | Dorm | EF 1 | Exhaust Fan 3rd Floor A-Wing | A 48 | 1 | 3/4 | 115/208-230 | 56 | 1 | 1725 | |||||
| 90358 | Dorm | EF 2 | Exhaust Fan 3rd Floor B-Wing | A 48 | 1 | 3/4 | 115/208-230 | 56 | 1 | 1725 | Bld is being renovated | ||||
| 90367 | Support Group Dorm | 1 | 1st Floor BLD A | B 53 | 1 | 24x24x2 | 2 | 12x24x2 | 2 | Marathon Electric Motor | |||||
| 90367 | Support Group Dorm | OAU | 1st Floor BLD A | A 38 | 1 | Tappan Split Unit Mod# B3BV-024K Ser#B3B0004075 | |||||||||
| 90367 | Support Group Dorm | 2 | 2nd Floor BLD A | B 36 | 2 | 24x24x2 | 3 | 12x24x2 | 3 | 7.5 | 200 | 1750 | Tappan Split Unit Mod# B3BV-024K Ser#B3B0004075 | ||
| 90367 | Support Group Dorm | OAU | 2nd Floor BLD A | A 38 | 1 | ||||||||||
| 90367 | Support Group Dorm | 3 | 3rd Floor BLD A | B 36 | 2 | 24x24x2 | 3 | 12x24x2 | 3 | 7.5 | 200 | 1750 | |||
| 90367 | Support Group Dorm | OAU | 3rd Floor BLD A | A 38 | 1 | ||||||||||
| 90367 | Support Group Dorm | 4 | 1st Floor BLD B | B 53 | 1 | 24x24x2 | 2 | 12x24x2 | 2 | ||||||
| 90367 | Support Group Dorm | OAU | 1st Floor BLD B | A 38 | 1 | ||||||||||
| 90367 | Support Group Dorm | 5 | 2nd Floor BLD B | B 35 | 2 | 24x24x2 | 3 | 12x24x2 | 3 | 7.5 | 208-230/460 | 213T | 3 | 1740 | |
| 90367 | Support Group Dorm | OAU | 2nd Floor BLD B | A 38 | 1 | ||||||||||
| 90367 | Support Group Dorm | 6 | 3rd Floor BLD B | B 36 | 2 | 24x24x2 | 3 | 12x24x2 | 3 | 7.5 | 200 | 1750 | |||
| 90367 | Support Group Dorm | OAU | 3rd Floor BLD B | A 38 | 1 | ||||||||||
| 90367 | Support Group Dorm | 7 | Inside main mech room | A 41 | 1 | 20x25x4 | 1 | 200 | P145T | 3 | 1745 | ||||
| 90367 | Support Group Dorm | 8 | middle near Day Room | A 45 | 1 | 20x20x2 | 4 | 200 | P145T | 3 | 1745 | ||||
| 90367 | Support Group Dorm | EF-1 | Exhaust Fan BLD A | A 43 | 1 | 2 | 208-230/460 | 145T | 3 | 1725 | |||||
| 90367 | Support Group Dorm | Air Comp | OUTSIDE MECH RM | A 44 | 2 | Blow Down | Oil | Marathon Electric | |||||||
| 90367 | Support Group Dorm | EF-2 | Exhaust Fan BLD B | A 46 | 1 | 2 | 208-230/460 | 145T | 3 | 1725 | |||||
| 90368 | 2 | Bottom Middle of blds | A 47 | 1 | 16x20x4 | 4 | 1 | 208 | N143T | 3 | 1745 | Magnetek | |||
| 90368 | 3B | Top Middle | A 46 | 1 | 16x20x4 | 2 | 1 | 208 | N143T | 3 | 1745 | ||||
| 90368 | 2B | Middle Middle | A 46 | 1 | 16x20x4 | 2 | 1 | 208 | N143T | 3 | 1745 | Magnetek | |||
| 90368 | 1B | Bottom Middle | A 46 | 1 | 16x20x4 | 2 | 1 | 208 | S182T | 3 | 1760 | Dayton Motor | |||
| 90368 | 1 | Bottom by Chiller plant | BX 40 | 1 | 16x20x4 | 4 | 1.5 | 208 | P145I | 3 | 1745 | ||||
| 90369 | 1 | 1st Floor Rec Room | B 44 | 1 | 16x20x4 | 4 | |||||||||
| 90369 | 2 | 1st Floor B-Wing | A 45 | 1 | 16x20x4 | 2 | |||||||||
| 90369 | 3 | 2nd Floor B-Wing | A 43 | 1 | 16x20x4 | 2 | |||||||||
| 90369 | 4 | 3rd Floor B-Wing | A 43 | 1 | 16x20x4 | 2 | |||||||||
| 90369 | 5 | 1st Floor A-Wing Mech Room | A 45 | 1 | 16x20x4 | 2 | |||||||||
| 90369 | 6 | 2nd Floor A-Wing Mech Room | A 43 | 1 | 16x20x4 | 2 | |||||||||
| 90369 | 7 | 3rd Floor A-Wing Mech Room | A 45 | 1 | 16x20x4 | 2 | |||||||||
| 90369 | 8 | Laundry Room A-wing side | A 41 | 1 | 16x20x4 | 4 | |||||||||
| 91009 | Red Horse Dorm | 4 | 1st Floor B-Wing Mech Room | B 42 | 1 | 20x24x2 | 3 | 6 | 200 | S184T | 3 | 1760 | |||
| 91009 | Red Horse Dorm | 7 | Day Room and Mail Boxes | A 48 | 1 | 20x20x2 | 2 | 7.5 | 200 | S213T | 3 | 1760 | |||
| 91009 | Red Horse Dorm | 1 | 1st Floor A-Wing Mech Room | B 35 | 1 | 18x24x2 | 2 | 20x24x2 | 1 | 7.5 | 200 | S213T | 3 | 1760 | Marathon |
| 91009 | Red Horse Dorm | 2 | 2nd Floor A-Wing Mech Room | B 35 | 1 | 18x24x2 | 2 | 20x24x2 | 1 | 10 | 200 | S215T | 3 | 1766 | |
| 91009 | Red Horse Dorm | 3 | 3rd Floor A-Wing Mech Room | B 46 | 1 | 20x24x2 | 3 | 1 | 115/208-230 | 56 | 1 | 1725 | |||
| 91009 | Red Horse Dorm | E/F 4A | Exhaust Fan 3rd Floor mech A-wing | B 68 | 1 | ||||||||||
| 91009 | Red Horse Dorm | 5 | 2nd Floor B-Wing Mech room | B 42 | 1 | 24x24x2 | 2 | 12x24x2 | 1 | 1/4 | 115 | 48Z | 1 | 1725 | Gould Motor |
| 91009 | Red Horse Dorm | O/A Fan-5 | Outside Air Fan attached to AHU 5 | A 38 | 1 | 1/4 | 115 | 48Z | 1 | 1725 | Get Key to Mech Room from Inside BLD | ||||
| 91009 | Red Horse Dorm | O/A Fan-3 | Outside Air Fan Attached to AHU 3 | A 45 | 1 | 20x24x2 | 2 | 18x24x2 | 2 | Get Key to Mech Room from Inside BLD | |||||
| 91009 | Red Horse Dorm | 6 | 3rd Floor B-Wing Mech room | B 44 | 1 | 24x24x2 | 2 | 12x24x2 | 4 | 1/4 | 115 | 48Z | 1 | 1725 | |
| 91009 | Red Horse Dorm | O/A Fan-6 | Outside Air Fan attached to AHU 6 | A 54 | 1 | 24x24x2 | 2 | 18x24x2 | 2 | ||||||
| 91009 | Red Horse Dorm | EF 5A | Exhaust Fan 3rd Floor mech B-wing | B 66 | 1 | ||||||||||
| 91053 | POD Dorms | 1 | 91053 A/H | B 62 | 2 | 16x20x4 | 16 | Carrier Crusader Mod# 5855C090-LC Ser# 2192A03114 | |||||||
| 91054 | POD Dorms | 1 | Mechanical Room | A 48 | 1 | 16x20x4 | 2 | 15 | 200 | 245T | 3 | 1760 | |||
| 91055 | POD Dorms | 1 | 91055 A/H | B 62 | 2 | 16x20x4 | 16 | ||||||||
| 91056 | POD Dorms | 1 | 91056 A/H | B 62 | 2 | 16x20x4 | 16 |