| Roof Summary | 13-Jul-18 |
| ROOFING BID SCHEDULE | |
| IDIQ 2018-2022 | |
| Project No. CP # Master Spec. | |
| 2018 THROUGH 2022 |
| Year | Basic | Option Year 1 | Option Year 2 | Option Year 3 | Option Year 4 | TOTAL |
| Subtotal | $0.00 | $0.00 | $0.00 | $0.00 | $0.00 | $ - 0 |
&P of &N &F - &A
BASE YEAR
| 13-Jul-18 | |
| ROOFING BID SCHEDULE | |
| IDIQ 2018-2022 | |
| Project No. CP# Master Spec |
| BASE YEAR | ESCALATION | TOTAL PRICE | Contractor | |||||
| 0.00 | ||||||||
| LINE ITEM | SPEC | DESCRIPTION | Unit | EST. QTY. | UNIT PRICE | EST. TOTAL PRICE | UNIT PRICE | EST. TOTAL PRICE |
| 02 41 00 | DIVISION2-SELECTIVE DEMOLITION | |||||||
| 0001 | 41 13 84 | REMOVE DEMO SPLASH BLOCKS | SF | 50 | $0.00 | |||
| DIVISION 2-ASBESTOS ABATEMENT/ LEAD CONTROLS | ||||||||
| 0002 | 02 82 13 | CLASS I AND/OR CLASS II ASBESTOS CONTAINING ROOF MATERIALS (ACRM) ROOF MEMBRANE | SF | 50 | $0.00 | |||
| 0003 | 02 82 16 | CEMENTITIOUS ASBESTOS FIBER ROOF DECK/FORM BOARD | SF | 50 | $0.00 | |||
| 0004 | 02 83 13 | LEAD CONTROLS | SF | 50 | $0.00 | |||
| 0005 | 04 01 20 | DIVISION 4-MASONRY | ||||||
| 0006 | 01 02 20 | CONCRETE MASONRY UNITS TO INCLUDE GROUTING, TUCK POINTING, FORMWORK, AND SUPPORTS. PERFORM WORK IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. | SF | 200 | $0.00 | |||
| 0007 | 01 30 20 | WATER BLAST CLEAN EXISTING MASONRY SURFACE IN ACCOURDANCE WITH PAINT MANUFACTURER'S RECOMMENDATIONS. | SF | 200 | $0.00 | |||
| 05 05 05 | DIVISION 5-STEEL ROOF DECK | |||||||
| 0008 | 05 05 10 | REMOVE EXISTING STEEL ROOF DECK AND REPLACE WITH NEW STEEL ROOF DECK | SQ | 25 | $0.00 | |||
| 0009 | 05 05 10 | DEMO LADDER WITH CAGE | VLF | 20 | $0.00 | |||
| 0010 | 05 05 10 | DEMO LADDER WITHOUT CAGE | VLF | 20 | $0.00 | |||
| 0011 | DIVISION 5-METALS | |||||||
| 0012 | 05 40 00 | COLD-FORMED METAL FRAMING | ||||||
| 0013 | 42 23 70 | COLD-FORMED METAL FRAMING MEMBERS OR SOFFIT FRAMING, TO INCLUDE SADDLES, CANT STRIPS, CURBS FOR SCUTTLES AND VENTILATORS, AND NAILERS ATTACHED AT THE TOPS OF CONCRETE OR MASONRY CURBS, EXPANSION JOINTS AND ROOF EDGES. FRAMING MEMBERS ARE 4" TO 8" WIDE BY 18 GAUGE OR THINNER. | LF | 250 | $0.00 | |||
| 0014 | 12 23 78 | RETROFIT SUB-PURLIN AND/OR FORMED SHAPED FRAMING SYSTEM MECHANICALLY FASTENED TO EXISTING AND/OR SUBSTRATE IN ACCORDANCE WITH MANUFACTURES SPECIFICATIONS. MINIMUM 16 GAUGE THICKNESS | LF | 250 | $0.00 | |||
| 0015 | 05 50 13 | METAL FABRICATION | ||||||
| 0016 | SHOP PRIMED STEEL MATERIALS INCLUDING BUT NOT LIMITED TO: PLATES, ANGLES, ANCHOR BOLTS, STEEL PIPE SLEEVES, WEDGE TYPE INSERTS, EXPANSION ANCHORS, FRAMING, SUPPORTS AND FABRICATED ITEMS FOR APPLICATIONS THAT ARE NOT SPECIFIED IN OTHER SPECIFICATION SECTIONS. | LB | 125 | $0.00 | ||||
| 0017 | 05 51 33 | STAIRS AND LADDERS | ||||||
| 0018 | 51 33 13 | FABRICATE AND INSTALL ALUMINUM ROOF ACCESS STAIRS OR LADDERS WITH CAGE | VLF | 10 | $0.00 | |||
| 0019 | 51 33 13 | FABRICATE AND INSTALL GALVANIZED STEEL ROOF ACCESS STAIRS OR LADDERS WITH CAGE | VLF | 10 | $0.00 | |||
| 0020 | 05 52 00 | PIPE AND TUBE RAILINGS | ||||||
| 0021 | 52 13 50 | FABRICATE AND INSTALL A SIDE OR BASE MOUNT ALUMINUM PIPE AND/OR TUBE GUARDRAIL SYSTEM | LF | 20 | $0.00 | |||
| 0022 | 52 13 50 | FABRICATE AND INSTALL A SIDE OR BASE MOUNT GALVANIZED STEEL PIPE AND/OR TUBE GUARDRAIL SYSTEM | LF | 20 | $0.00 | |||
| 0023 | 05 05 10 | REMOVE AND DISPOSE OF PIPE AND/OR TUBE GUARDRAIL SYSTEM | LF | 20 | $0.00 | |||
| 06 10 00 | DIVISION 6-ROUGH CARPENTRY | |||||||
| 0024 | 05 05 10,11 10 02 | REMOVE AND REPLACE EXISTING WOOD BLOCKING, NAILER, OR FRAMING, NOMINAL 2" THICK | LF | 250 | $0.00 | |||
| 0025 | 05 05 10, 11 10 30 | REMOVE AND REPLACE EXISTING WOOD FASCIA BOARDS, NOMINAL 2" THICK | LF | 125 | $0.00 | |||
| 0026 | 05 05 10, 22 13 50 | REMOVE AND REPLACE EXISTING HARDBOARD SOFFIT (3/8") | SF | 500 | $0.00 | |||
| 0027 | FURNISH AND INSTALL PRESERVATIVE TREATED WOOD ROOF NAILERS, WHICH INCLUDES WOOD SADDLES OR CRICKETS, CANT STRIPS, CURBS FOR SCUTTLES AND VENTILATORS, AND WOOD NAILERS BOLTED TO TOPS OF CONCRETE OR MASONRY CURBS AND AT EXPANSION JOINTS | BF | 500 | $0.00 | ||||
| 0028 | 05 05 10,06 33 10 | REMOVE AND REPLACE 3/8", 5/8"OR 3/4" PLYWOOD ROOF SHEATHING or SOFFIT | SF | 100 | $0.00 | |||
| 0029 | 05 05 10, 16 33 10 | REMOVE AND REPLACE ROOF DECKING , WHICH INCLUDES 1x OR 2x DECKING | SF | 100 | $0.00 | |||
| 0030 | FURNISH AND INSTALL ROOFING LUMBER FOR RESIDENTIAL UNITS, WHICH INCLUDES RAFTERS, STUDS, PLATES, CAPS, COLLAR BEAMS, SLEEPERS, NAILING STRIPS, SILLS, HEADERS AND FASCIA | BF | 100 | $0.00 | ||||
| 7050510 | DIVISION 7 DEMO | |||||||
| 0031 | DEMOLITION, HAULING, AND DISPOSAL OF UP TO 5-PLY BURS WITH FLASHINGS, GRAVEL, ETC. (DOES NOT INCLUDE INSULATION) | SQ | 100 | $0.00 | ||||
| 0032 | DEMOLITION, HAULING, AND DISPOSAL OF INSULATION UP TO 2" THICK | SQ | 100 | $0.00 | ||||
| 0033 | DEMOLITION, HAULING, AND DISPOSAL OF INSULATION OVER 2" THICK | BF | 50 | $0.00 | ||||
| 0034 | REMOVE AND DISPOSE OF EXISTING ROOF SHINGLE SYSTEM AND UNDERLAYMENT, INCLUDING FLASHING AND DRIP EDGES | SQ | 30 | $0.00 | ||||
| 0035 | REMOVE AND DISPOSE OF EXISTING ROLL ROOFING AND UNDERLAYMENT, INCLUDING FLASHING AND DRIP EDGES | SQ | 25 | $0.00 | ||||
| 0036 | DEMOLITION, REMOVAL, AND DISPOSAL OF EXISTING METAL ROOFING SYSTEM | SQ | 170 | $0.00 | ||||
| 0037 | DEMOLITION, HAULING, AND DISPOSAL OF AGGREGATE BALLAST. INCLUDE SPUDDING BACK AND VACUUMING LOOSE AGGREGATE FROM ENTIRE ROOF SURFACE. | SQ | 50 | $0.00 | ||||
| 0038 | REMOVE SINGLE PLY ROOFING (INCLUDING PVC, EPDM, PIB, TPO AND OTHER MEMBRANE ROOFING) DOWN TO THE DECK. INCLUDE MEMBRANE, PENETRATION & WALL FLASHINGS AND MEMBRANE FASTENERS. NOT TO INCLUDE INSULATION, CRICKETS AND INSULATION FASTENERS. | SQ | 50 | $0.00 | ||||
| 0039 | 02 20 | FLASHING, SHEET METAL | SF | 200 | $0.00 | |||
| 0040 | 05 20 | BUILT-IN GUTTERS | LF | 100 | $0.00 | |||
| 0041 | 06 20 | WALL INSULATION, AIR/VAPOR BARRIER | SF | 1000 | $0.00 | |||
| 0042 | 13 25 | PLUMBING VENT FLASHING | EA | 50 | $0.00 | |||
| 0043 | 13 75 | RIDGE VENT STRIP ALUMINUM | LF | 50 | $0.00 | |||
| 0044 | 21 20 | ROOF EDGE, ALUMINUM SOFFIT AND FASICA | LF | 1000 | $0.00 | |||
| 0045 | 22 20 | DRIP EDGE | LF | 1000 | $0.00 | |||
| 0046 | 22 70 | GRAVEL STOP | LF | 1000 | $0.00 | |||
| 0047 | 23 70 | SHEET METAL COPING, UP TO 12" WIDE | LF | 250 | $0.00 | |||
| 0048 | 26 20 | ROOF VENTILATION, LOUVERED GABLE VENT | EA | 2 | $0.00 | |||
| 0049 | 26 70 | REMOVE ROOF HATCH | EA | 1 | $0.00 | |||
| 0050 | 26 75 | RAFTER VENTS | EA | 2 | $0.00 | |||
| 0051 | 27 20 | SOFFIT VENT AND/OR FASICA VENT | LF | 1 | $0.00 | |||
| 0052 | 27 25 | SOFFIT VENT STRIP,ALUMINUM,3" to 4" WIDE | LF | 20 | $0.00 | |||
| 0053 | 28 70 | CANT STRIP | LF | 200 | $0.00 | |||
| 0054 | 45 50 | ROOF HATCH | EA | 1 | $0.00 | |||
| 0055 | 49 70 | SIDING HORIZONTAL WOOD CLAPBOARDS | SF | 100 | $0.00 | |||
| 0056 | 50 25 | EXTERIOR INSULATION FINISH SYSTEMS (EIFS) | SF | 50 | $0.00 | |||
| 0057 | 58 80 | STEEL SIDING,CORRUGATED/RIBBED | SF | 10000 | $0.00 | |||
| 0058 | 59 20 | WATER PROVING, PROTECTION/DRAIN BOARD UP TO 1/2" | SF | 1000 | $0.00 | |||
| 07 22 16 | DIVISION 7-ROOF AND DECK INSULATION | |||||||
| POLYISOCYANURATE BOARD INSULATION | ||||||||
| 0059 | 17 05 | 1" THICK, R 5.7 | SF | 200 | $0.00 | |||
| 0060 | 17 15 | 1.5" THICK, R 8.6 | SF | 100 | $0.00 | |||
| 0061 | 17 25 | 2" THICK, R 11.4 | SF | 200 | $0.00 | |||
| 0062 | 17 45 | 3" THICK, R17.1 | SF | 200 | $0.00 | |||
| 0063 | 4" THICK, R22.8 | SF | 100 | $0.00 | ||||
| 0064 | 5" THICK, R28.5 | SF | 200 | $0.00 | ||||
| 0065 | 5.5" THICK, R31.3 | SF | 50 | $0.00 | ||||
| 0066 | 15 52 | 40 PSI EXTRUDED POLYSTYRENE 2" THICK R10 | SF | 17,000 | $0.00 | |||
| 0067 | 16 50 | EXPANDED PERLITE COVER BOARD 3/4" R2.08 | SF | 17,000 | $0.00 | |||
| 0068 | 16 60 | EXPANDED PERLITE COVER BOARD 1" R2.78 | SF | 5,000 | $0.00 | |||
| 0069 | 17 65 | TAPERED FILL INSULATION BOARD FOR DRAINAGE | BF | 5,000 | $0.00 | |||
| 07 22 00 | PROTECTION BOARDS: | |||||||
| 0070 | 7221610 | GLASS MAT GYPSUM ROOF BOARD | SF | 1000 | $0.00 | |||
| 0071 | 7221610 | HIGH DENSITY WOOD FIBER BOARD | SF | 1000 | $0.00 | |||
| 0072 | 7511330 | FIBER CANTS | LF | 250 | $0.00 | |||
| 0073 | 7511330 | WOOD CANTS | LF | 250 | $0.00 | |||
| 0074 | 7251010 | SHEATING PAPER FOR WOOD DECKS | SF | 5000 | $0.00 | |||
| 0075 | 07 21 16 | BATT ROOF INSULATION, R-19 | SF | 1,000 | $0.00 | |||
| 0076 | 07 21 16 | BATT ROOF INSULATION, R-30 | SF | 1,000 | $0.00 | |||
| 0077 | 1334195 | METAL ROOF INSULATION, VINYL FACED R30 | SQ | 170 | $0.00 | |||
| 07 24 13 | DIVISION 7-EXTERIOR INSULATION AND FINISH SYSTEMS | |||||||
| 0078 | 10 0105 | FIELD APPLIED 2" EPS INSULATION" | SF | 500 | $0.00 | |||
| 0079 | 10 0140 | PREMIUM FINISH ADD | SF | 500 | $0.00 | |||
| 0080 | 10 0150 | REINFORCING FABRIC | SF | 500 | $0.00 | |||
| 0081 | 10 0180 | COLOR OR TEXTURE CHANGE | SF | 500 | $0.00 | |||
| 0082 | 10 0190 | SUBSTRATE BASE LEVELING COAT | SF | 500 | $0.00 | |||
| 0083 | 10 0210 | SUBSTRATE SEALING COAT | SF | 500 | $0.00 | |||
| 0084 | 10 0437 | CRACK REPAIR 50 MIL, REINFORCED | SF | 200 | $0.00 | |||
| 07 31 13 | DIVISION 7-SHINGLE ROOFING SYSTEMS | |||||||
| 0085 | 10 0205 | FURNISH AND INSTALL NEW 3-TAB MINERAL SURFACED ASPHALT STRIP SHINGLE SYSTEM 30 YEAR PNEUMATIC NAILED | SQ | 100 | $0.00 | |||
| 0086 | 10 0505 | FURNISH AND INSTALL NEW ARCHITECTURAL DIMENSIONAL ASHPALT SHINGLE SYSTEM CLASS A 250- 270 LB/SQ 30 YR PNEUMATIC NAILED | SQ | 30 | $0.00 | |||
| 0087 | REMOVE AND REPLACE EXISTING SHINGLES WITH NEW ASPHALT STRIP SHINGLES TO MATCH ADJACENT AREAS, PARTIAL REPAIRS | SQ | 10 | $0.00 | ||||
| 0088 | ADD FOR STEEP ROOFS (7 TO 12 PITCH OR GREATER) | SQ | 50 | $0.00 | ||||
| DIVISION 7-STANDING SEAM METAL ROOF SYSTEM | ||||||||
| 0089 | 07 41 13 | NEW METAL ROOF PANELS, ARCHITECTURAL/NON-STRUCTURAL PER SPEC | SQ | 100 | $0.00 | |||
| 0090 | 07 61 14 | NEW STEEL STANDING SEAM METAL ROOFING, STRUCTURAL, PER SPEC. | SQ | 100 | $0.00 | |||
| 0091 | 07 61 15 | NEW ALUMINUM STANDING SEAM METAL ROOF, STRUCTURAL, PER SPEC. | SQ | 50 | $0.00 | |||
| 0092 | 07 71 19 | FASCIA PANEL SYSTEM | SF | 500 | $0.00 | |||
| 0093 | 07 46 73 | NON-PERFORATED SOFFIT PANEL | SF | 500 | $0.00 | |||
| 0094 | 07 46 73 | PERFORATED SOFFIT PANEL | SF | 100 | $0.00 | |||
| 07 42 13 | DIVISION 7-METAL WALL PANELS | |||||||
| 0095 | 20 2760 | FURNISH AND INSTALL METAL WALL PANELS | SF | 250 | $0.00 | |||
| 0096 | FURNISH AND INSTALL FABRICATED METAL WALL PANEL ASSEMBLY (INCLUDING INSULATION) | SF | 10000 | $0.00 | ||||
| multiple | DIVISION 7-UNDERLAYMENT | |||||||
| 0097 | FELT, ASPHALT SATURATED, 30 POUND | SQ | 150 | $0.00 | ||||
| 0098 | SELF ADHERING LEAK BARRIER (PEAL AND STICK) | SQ | 150 | $0.00 | ||||
| 07 51 13 | DIVISION 7-BITUMINOUS ROOFING (BURS) | |||||||
| 0099 | 4-PLY BURS WITH SBS MODIFIED CAP SHEET | SQ | 100 | $0.00 | ||||
| 0100 | multiple | REMOVE AND REPLACE PITCH PAN | EA | 40 | $0.00 | |||
| FOR RESIDENTIAL UNITS | ||||||||
| 0101 | SINGLE-PLY SBS MODIFIED CAP SHEET FOR RESIDENTIAL UNITS | SQ | 10 | $0.00 | ||||
| 07 01 50 | DIVISION 7-PARTIAL BURS REPAIRS | |||||||
| 0102 | REPAIRS BLISTERS | SF | 500 | $0.00 | ||||
| 0103 | REPAIR SPLITS | LF | 200 | $0.00 | ||||
| 0104 | REPAIR RIDGES | LF | 200 | $0.00 | ||||
| 0105 | APPLY RESATURANT AND INSTALL NEW AGGREGATE ON EXPOSED FELT AREAS | SF | 500 | $0.00 | ||||
| 07 31 13 | DIVISION 7-PREPARED ROLL ROOFING | |||||||
| 0106 | FURNISH AND INSTALL NEW MINERAL SURFACED ASPHALT PREPARED ROLL ROOFING | SQ | 20 | $0.00 | ||||
| 0107 | CUT-OUT AND PATCH ROLL ROOFING | SQ | 5 | $0.00 | ||||
| multiple | DIVISION 7-TRAFFIC-BEARING ROOF DECK SURFACING | |||||||
| 0108 | 07 51 13 | TRAFFIC-BEARING ROOF SURFACING SYSTEM | SQ | 5 | $0.00 | |||
| 07 54 19 | DIVISION 7-SBS MODIFIED BITUMINOUS MEMBRANE | |||||||
| 0109 | 10 8850 | FURNISH/INSTALL MOD.BIT.RFNG.,SBS GRAN SURF.CAP SHEET, POLY.REINF | SF | 5000 | $0.00 | |||
| 0110 | FURNISH/INSTALL HEAVYWEIGHT BASE/PLY SHEET, REINFORCED, 87 to 90 MIL THICK | SF | 5000 | $0.00 | ||||
| 0111 | 10 8800 | FURNISH/INSTALL GRANULAR SURFACE FLASHING, 160 MIL | SF | 2000 | $0.00 | |||
| 0112 | 10 8800 | FURNISH/INSTALL COLD PROCESS AHESIVE, 20 to 30 MIL THICK | SF | 5000 | $0.00 | |||
| 0113 | 10 2050 | HEAT WELD SEAMS | LF | 1000 | $0.00 | |||
| 07 53 23 | DIVISION 7 ETHYLENE-PROPYLENE-DIEN-MONOMER ROOFING (EPDM) | |||||||
| 0114 | 3700 | FURNISH/INSTALL MECHANICALLY ATTACHED EPDM, 45 MIL,0.28 PSF | SQ | 5 | $0.00 | |||
| 0115 | 3800 | FURNISH/INSTALL FULLY ADHERED WITH ADHESIVE EPDM, 45 MIL,0.28 PSF PVC SYSTEM- 72 MILS | SQ | 5 | $0.00 | |||
| 0116 | 4700 | FURNISH/INSTALL MECHANICALLY ATTACHED EPDM, 60 MIL,0.40 PSF | SQ | 5 | $0.00 | |||
| 0117 | 4800 | FURNISH/INSTALL FULLY ADHERED WITH ADHESIVE EPDM, 60 MIL,0.40 PSF | SQ | 5 | $0.00 | |||
| 0118 | 4850 | SEAM TAPE FOR MEMBRANE 3" x 100' ROLL | EA | 5 | $0.00 | |||
| 0119 | 4900 | BATTEN STRIPS 10' SECTIONS | EA | 10 | $0.00 | |||
| 0120 | 4910 | COVER TAPE for BATTEN STRIPS 6" x 100' ROLL | EA | 10 | $0.00 | |||
| 0121 | 4970 | ADHESIVE FOR FULLY ADHERED SYSTEMS, 60 SF/GAL | GAL | 10 | $0.00 | |||
| 07 54 19 | DIVISION 7-POLYVINYL-CHLORIDE ROOFING | |||||||
| 0122 | 8850 | FURNISH/INSTALL FULLY ADHERED PVC SYSTEM- 72 MILS | SQ | 5 | $0.00 | |||
| 0123 | 8800 | FURNISH/INSTALL MECHANICALLY FASTENED PVC SYSTEM- 72 MIL | SQ | 5 | $0.00 | |||
| 0124 | PVC LAMINATED METAL FLASHING UP TO 18" STRETCH OUT | LF | 20 | $0.00 | ||||
| 0125 | PVC LAMINATED METAL FLASHING 18.1" TO 36" STRETCH OUT | LF | 20 | $0.00 | ||||
| 0126 | PVC VENT BOOTS | EA | 5 | $0.00 | ||||
| 0127 | PVC UNIVERSAL CORNERS | EA | 20 | $0.00 | ||||
| 0128 | PATCH AND REPAIR PVC SYSTEM | SF | 5 | $0.00 | ||||
| 07 14 00 | DIVISION 7-FLUID APPLIED WATERPROOFING | |||||||
| 0129 | FLUID APPLIED COATING SYSTEM FOR METAL ROOFS | SQ | 1 | $0.00 | ||||
| 0130 | ENERGY STAR RATED COATING SYSTEM APPLIED TO NEW BUR ROOFING WITH MODIFIED CAP SHEET | SQ | 1 | $0.00 | ||||
| 0131 | 07 56 10 | ELASTOMERIC COATING FOR ROOF REPAIRS | SQ | 1 | $0.00 | |||
| 07 71 19 | DIVISION 7-SHEET METAL WORK, GENERAL | |||||||
| FURNISH AND INSTALL NEW GRAVEL GUARD/FASCIA (FACE DIMENSION) | ||||||||
| 0132 | GALVANIZED METAL, 4"- 5" | LF | 1000 | $0.00 | ||||
| 0133 | GALVANIZED METAL, 6" - 7" | LF | 1000 | $0.00 | ||||
| 0134 | ALUMINUM, 4" - 5" | LF | 200 | $0.00 | ||||
| 0135 | ALUMINUM, 6" - 7" | LF | 100 | $0.00 | ||||
| 0136 | 2-PIECE GALVANIZED METAL, 7" - 10" | LF | 50 | $0.00 | ||||
| 0137 | 2-PIECE GALVANIZED METAL, 10" - 12" | LF | 50 | $0.00 | ||||
| 0138 | 2-PIECE ALUMINUM, 7" - 10" | LF | 50 | $0.00 | ||||
| 0139 | 2-PIECE ALUMINUM, 10" - 12" | LF | 50 | $0.00 | ||||
| FURNISH AND INSTALL: | ||||||||
| 0140 | GALVANIZED METAL DRIP EDGE | LF | 250 | $0.00 | ||||
| 0141 | GALVANIZED METAL COUNTERFLASHING | SF | 150 | $0.00 | ||||
| 0142 | 07 65 10 | GALVANIZED METAL VALLEY FLASHING | SF | 150 | $0.00 | |||
| 0143 | GALVANIZED METAL STEP FLASHING | SF | 100 | $0.00 | ||||
| 0144 | GALVANIZED METAL BASE FLASHING | SF | 100 | $0.00 | ||||
| 0145 | GALVANIZED METAL FLASHING- FLAT SHEET | SF | 100 | $0.00 | ||||
| 0146 | GALVANIZED METAL CAP FLASHING | SF | 100 | $0.00 | ||||
| 0147 | 07 71 43 | ALUMINUM DRIP EDGE | LF | 250 | $0.00 | |||
| 0148 | ALUMINUM COUNTERFLASHING | SF | 150 | $0.00 | ||||
| 0149 | ALUMINUM VALLEY FLASHING | SF | 100 | $0.00 | ||||
| 0150 | ALUMINUM STEP FLASHING | SF | 100 | $0.00 | ||||
| 0151 | ALUMINUM BASE FLASHING | SF | 100 | $0.00 | ||||
| 0152 | ALUMINUM FLASHING - FLAT SHEET | SF | 100 | $0.00 | ||||
| 0153 | 04 72 10 | ALUMINUM CAP FLASHING | SF | 100 | $0.00 | |||
| 0154 | METAL RIDGE VENT | LF | 100 | $0.00 | ||||
| REMOVE EXISTING EXPANSION JOINT AND INSTALL NEW EXPANSION JOINT: | ||||||||
| 0155 | 07 71 29 | ELASTOMERIC TYPE (NEOPRENE BELLOWS) | LF | 10 | $0.00 | |||
| 0156 | 2500 | ALUMINUM CAPPED CURB | LF | 20 | $0.00 | |||
| 0157 | GALVANIZED CAPPED CURB | LF | 20 | $0.00 | ||||
| 0158 | REMOVE AND REPLACE VENTILATOR, ROOFTOP | EA | 1 | $0.00 | ||||
| 0159 | REMOVE AND REPLACE VENTILATOR, RIDGE | LF | 20 | $0.00 | ||||
| 0160 | REMOVE AND REPLACE VENTILATOR, GABLE | EA | 2 | $0.00 | ||||
| 0161 | REMOVE AND REPLACE CURB ASSEMBLY, METAL WITH CRICKET, FACTORY FABRICATED AND FINISHED | EA | 2 | $0.00 | ||||
| 0162 | REMOVE AND REPLACE ROOF SCUTTLE | EA | 1 | $0.00 | ||||
| 07 71 23 | DIVISION 7-GUTTERS AND DOWNSPOUTS | |||||||
| 0163 | 01 20 | REMOVE EXISTING GUTTER AND DOWNSPOUTS, INCLUDING HANGERS | LF | 1000 | $0.00 | |||
| FURNISH AND INSTALL NEW GUTTER, BOX, INCLUDING HANGARS, BRACKETS, SEALANTS, ETC. | ||||||||
| 0164 | 24 GA. GALVANIZED/PRIMED, 4" X 5" | LF | 50 | $0.00 | ||||
| 0165 | 24 GA. GALVANIZED/PRIMED, 5" X 7" | LF | 50 | $0.00 | ||||
| 0166 | ALUMINUM, 4" X 5" | LF | 250 | $0.00 | ||||
| 0167 | ALUMINUM, 5" X 7" | LF | 100 | $0.00 | ||||
| 07 71 23 | FURNISH & INSTALL NEW DOWNSPOUTS, INCLUDES BRACKETS, ETC. | |||||||
| 0168 | 24 GA. GALVANIZED/PRIMED, 3" X 4" | LF | 200 | $0.00 | ||||
| 0169 | ALUMINUM, 3" X 4" | LF | 100 | $0.00 | ||||
| 0170 | FURNISH & INSTALL NEW PRE-FORMED CONCRETE SPLASHBLOCKS | EA | 20 | $0.00 | ||||
| 0171 | FURNISH AND INSTALL NEW THROUGH WALL SCUPPERS | EA | 10 | $0.00 | ||||
| FURNISH AND INSTALL CONDUCTOR HEAD | EA | 2 | $0.00 | |||||
| 05 40 00 | DIVISION 7-MANUFACTURED ROOF FRAMING SYSTEM | |||||||
| 0172 | RETROFIT ROOFING & STRUCTURAL-UP TO 6/12 SLOPE <= 100 SQ | SQ | 5 | $0.00 | ||||
| 0173 | RETROFIT ROOFING & STRUCTURAL-UP TO 6/12 SLOPE =>100 SQ | SQ | 5 | $0.00 | ||||
| 07 92 00 | DIVISION 7-CAULKING AND SEALANTS | |||||||
| 0174 | REMOVE EXISTING CAULKING, CLEAN JOINT | LF | 500 | $0.00 | ||||
| 0175 | SILICONE CAULKING/SEALANT | LF | 250 | $0.00 | ||||
| 0176 | CAULKING, MISCELLANEOUS APPLICATION (SONNEBORN, SONOLASTIC NP-1, OR APPROVED EQUAL) | LF | 250 | $0.00 | ||||
| 08 05 05 | DIVISION 8 COMMON WORK RESULTS for OPENINGS | |||||||
| 0177 | 05 05 20 | REMOVE SHYLIGHTS, PLSTC DOMES, FLUSH CURB MTD | SF | 20 | $0.00 | |||
| 0178 | 62 13 20 | SKY LIGHTS FLUSH OR CURB MOUNTED VENTILATiING INSULATED PLEXIGLASS DOME | EA | 2 | $0.00 | |||
| 09 90 00 | DIVISION 9-PAINTING | |||||||
| 0179 | PAINT, BASE SCHEME, EXT. LATEX, 1 COAT | SF | 200 | $0.00 | ||||
| 0180 | PAINT, BASE SCHEME, EXT. LATEX, PRIMER AND 2 COATS | SF | 200 | $0.00 | ||||
| 22 00 00 | DIVISION 15-ROOF DRAINS | |||||||
| 0181 | REFLASH EXISTING ROOF DRAIN, INCLUDES NEW LEAD FLASHING, CLAMPING RING, AND CAST IRON DOME STRAINER | EA | 2 | $0.00 | ||||
| 0182 | REMOVE AND REPLACE EXISTING ROOF DRAIN, INCLUDES NEW CAST IRON DOME STRAINER | EA | 6 | $0.00 | ||||
| 26 41 00 | DIVISION 16-LIGHTING PROTECTION | |||||||
| REMOVE EXISTING LIGHTNING PROTECTION SYSTEM AND REINSTALL EXISTING LIGHTNING PROTECTION SYSTEM WITH NEW FASTENERS | ||||||||
| 0183 | REMOVE AND REINSTALL EXISTING CONDUCTOR | LF | 50 | $0.00 | ||||
| 0184 | REMOVE AND INSTALL NEW FASTENERS, INCLUDING LOOPS AND CLIPS | EA | 5 | $0.00 | ||||
| REMOVE EXISTING LIGHTNING PROTECTION SYSTEM AND INSTALL NEW LIGHTNING PROTECTION SYSTEM | ||||||||
| 0185 | AIR TERMINALS, INCLUDES COPPER BASE FOR NON-METAL ROOFS | EA | 10 | $0.00 | ||||
| 0186 | AIR TERMINALS, INCLUDES ALUMINUM BASE FOR METAL ROOFS | EA | 10 | $0.00 | ||||
| 0187 | CONDUCTORS | LF | 100 | $0.00 | ||||
| 0188 | FASTENERS, INCLUDES LOOPS AND CLIPS | EA | 30 | $0.00 | ||||
| 0189 | CONNECTORS | EA | 5 | $0.00 | ||||
| 0190 | COUNTERPOISE CONDUCTOR | LF | 50 | $0.00 | ||||
| 0191 | GROUNDING RODS, 3/4" DIAMETER x 60' LONG | EA | 3 | $0.00 | ||||
| 0192 | SURGE PROTECTION | EA | 1 | $0.00 | ||||
| 0193 | FURNISH AND INSTALL GROUND ACCESS PVC TEST WELL, 12" I.D. X 24" LONG WITH 1/4" GALVANIZED FRICTION FIT COVER WITH THE WORD "GROUND" ENGREAVED ON TOP OF THE COVER | EA | 1 | $0.00 | ||||
| 0194 | UL SITE INSPECTION | EA | 1 | $0.00 | ||||
| MISCELLANEOUS ROOFING ITEMS | ||||||||
| 0195 | FURNISH AND INSTALL PERMANENT FALL PROTECTION ANCHORAGE (PER EACH ANCHOR POINT) | EA | 12 | $0.00 | ||||
| 0196 | DESIGN, PROVIDE AND INSTALL FLEXIBLE LIFE LINE FALL ARREST PROTECTION SYSTEM AROUND PERIMETER and NEAR RIGE CAPS. FALL PROTECTION NEEDS TO BE SURFACE MOUNTED TO METAL ROOFS (GRADE 316 STAINLESS STEEL 5/16" DIAMETER WIRE WITH BRACKETS) SYSTEM MUST BE CAPABLE TO SUPPORT UP TO THREE PEOPLE | LF | 400 | $0.00 | ||||
| 0197 | EXTEND PLUMBING VENTS | LF | 10 | $0.00 | ||||
| 0198 | FLEXIBLE VENT PIPE FLASHING (METAL ROOFS) | EA | 10 | $0.00 | ||||
| 0199 | REMOVE AND REPLACE LEAD FLASHING AT VENT THRU ROOF (VTR) | EA | 10 | $0.00 | ||||
| 0200 | REMOVE EXISTING VTR PENETRATION FLASHING AND REPLACE WITH COLLAR TYPE FLASHING | EA | 10 | $0.00 | ||||
| 0201 | REPAIR AND REPLACE SPALLS, HOLES, AND CRACKS IN EXISTING CONCRETE ROOF DECK | SF | 50 | $0.00 | ||||
| 0202 | FURNISH AND INSTALL VAPOR BARRIER OVER CONCRETE DECKS | SQ | 4 | $0.00 | ||||
| 0203 | DISCONNECT AND RECONNECT ELECTRICAL SERVICE (<200 AMP) | EA | 3 | $0.00 | ||||
| 0204 | REMOVE EXISTING CONDUIT, ETC. AND REPLACE WITH NEW 3/4" RIGID CONDUIT, INCLUDING WIRE, BOXES, FITTINGS, ETC. | LF | 30 | $0.00 | ||||
| 0205 | ROLL COIL RIDGE VENT | LF | 30 | $0.00 | ||||
| 0206 | SPUD EXISTING ROOF TO INSULATION | SQ | 50 | $0.00 | ||||
| 0207 | CUT AND PATCH CONCRETE | LF | 100 | $0.00 | ||||
| 0208 | TRENCH AND BACKFILL | LF | 100 | $0.00 | ||||
| 0209 | TESTING (CORE CUT) OF ROOFS-REPAIR TEST AREA | EA | 4 | $0.00 | ||||
| 0210 | MOISTURE INSPECTION BY THERMAL IMAGING SURVEY | SF | 1000 | $0.00 | ||||
| 0211 | AS-BUILT DRAWINGS PER SPEC. | JOB | 2 | $0.00 | ||||
| 0212 | ENGINEERING RATE STRUCTURAL | HR | 10 | $0.00 | ||||
| 0213 | ENGINEERING RATE STRUCTURAL - FALL PROTECTION | JOB | 30 | $0.00 | ||||
| 0214 | MECHANICAL SUBCONTRACTOR | HR | 10 | $0.00 | ||||
| 0215 | ELECTRICAL SUBCONTRACTOR | HR | 10 | $0.00 | ||||
| 0216 | LABOR RATE - MISCELLANEOUS WORK | MH | 40 | $0.00 | ||||
| SPECIAL CONDITIONS AND CIRCUMSTANCES | ||||||||
| 0217 | HEIGHT FACTOR, 30 FEET OR GREATER ABOVE GROUND, UNIT EACH=JOB | EA | 1 | $0.00 | ||||
| Subtotal | $0.00 | |||||||
| MODIFIERS | ||||||||
| 0218 | MULTIPLIER % TO BE ADDED TO TOTAL FOR URGENT TASK ORDER (UTO)/NON-STANDARD HOUR WORK-TEMPORARY DRY-IN WORK ONLY | % | 1 | $0.00 | ||||
| BASE YEAR TOTAL | $0.00 |
&"Arial,Bold"&10Page &P of &N &"Arial,Bold"&10&A - &F
OPTION YEAR 1
| 13-Jul-18 | |
| ROOFING BID SCHEDULE | |
| IDIQ 2018-2022 | |
| Project No. CP# Master Spec |
| OPTION YEAR 1 | ESCALATION | TOTAL PRICE | Contractor | |||||
| 0.00 | ||||||||
| LINE ITEM | SPEC | DESCRIPTION | Unit | EST. QTY. | UNIT PRICE | EST. TOTAL PRICE | UNIT PRICE | EST. TOTAL PRICE |
| 02 41 00 | DIVISION2-SELECTIVE DEMOLITION | |||||||
| 0001 | 41 13 84 | REMOVE DEMO SPLASH BLOCKS | SF | 50 | $0.00 | |||
| DIVISION 2-ASBESTOS ABATEMENT/ LEAD CONTROLS | ||||||||
| 0002 | 02 82 13 | CLASS I AND/OR CLASS II ASBESTOS CONTAINING ROOF MATERIALS (ACRM) ROOF MEMBRANE | SF | 100 | $0.00 | |||
| 0003 | 02 82 16 | CEMENTITIOUS ASBESTOS FIBER ROOF DECK/FORM BOARD | SF | 50 | $0.00 | |||
| 0004 | 02 83 13 | LEAD CONTROLS | SF | 50 | $0.00 | |||
| 0005 | 04 01 20 | DIVISION 4-MASONRY | ||||||
| 0006 | 01 02 20 | CONCRETE MASONRY UNITS TO INCLUDE GROUTING, TUCK POINTING, FORMWORK, AND SUPPORTS. PERFORM WORK IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. | SF | 100 | $0.00 | |||
| 0007 | 01 30 20 | WATER BLAST CLEAN EXISTING MASONRY SURFACE IN ACCOURDANCE WITH PAINT MANUFACTURER'S RECOMMENDATIONS. | SF | 100 | $0.00 | |||
| 05 05 05 | DIVISION 5-STEEL ROOF DECK | |||||||
| 0008 | 05 05 10 | REMOVE EXISTING STEEL ROOF DECK AND REPLACE WITH NEW STEEL ROOF DECK | SQ | 10 | $0.00 | |||
| 0009 | 05 05 10 | DEMO LADDER WITH CAGE | VLF | 20 | $0.00 | |||
| 0010 | 05 05 10 | DEMO LADDER WITHOUT CAGE | VLF | 20 | $0.00 | |||
| 0011 | DIVISION 5-METALS | |||||||
| 0012 | 05 40 00 | COLD-FORMED METAL FRAMING | ||||||
| 0013 | 42 23 70 | COLD-FORMED METAL FRAMING MEMBERS OR SOFFIT FRAMING, TO INCLUDE SADDLES, CANT STRIPS, CURBS FOR SCUTTLES AND VENTILATORS, AND NAILERS ATTACHED AT THE TOPS OF CONCRETE OR MASONRY CURBS, EXPANSION JOINTS AND ROOF EDGES. FRAMING MEMBERS ARE 4" TO 8" WIDE BY 18 GAUGE OR THINNER. | LF | 250 | $0.00 | |||
| 0014 | 12 23 78 | RETROFIT SUB-PURLIN AND/OR FORMED SHAPED FRAMING SYSTEM MECHANICALLY FASTENED TO EXISTING AND/OR SUBSTRATE IN ACCORDANCE WITH MANUFACTURES SPECIFICATIONS. MINIMUM 16 GAUGE THICKNESS | LF | 250 | $0.00 | |||
| 0015 | 05 50 13 | METAL FABRICATION | ||||||
| 0016 | SHOP PRIMED STEEL MATERIALS INCLUDING BUT NOT LIMITED TO: PLATES, ANGLES, ANCHOR BOLTS, STEEL PIPE SLEEVES, WEDGE TYPE INSERTS, EXPANSION ANCHORS, FRAMING, SUPPORTS AND FABRICATED ITEMS FOR APPLICATIONS THAT ARE NOT SPECIFIED IN OTHER SPECIFICATION SECTIONS. | LB | 200 | $0.00 | ||||
| 0017 | 05 51 33 | STAIRS AND LADDERS | ||||||
| 0018 | 51 33 13 | FABRICATE AND INSTALL ALUMINUM ROOF ACCESS STAIRS OR LADDERS WITH CAGE | VLF | 10 | $0.00 | |||
| 0019 | 51 33 13 | FABRICATE AND INSTALL GALVANIZED STEEL ROOF ACCESS STAIRS OR LADDERS WITH CAGE | VLF | 10 | $0.00 | |||
| 0020 | 05 52 00 | PIPE AND TUBE RAILINGS | ||||||
| 0021 | 52 13 50 | FABRICATE AND INSTALL A SIDE OR BASE MOUNT ALUMINUM PIPE AND/OR TUBE GUARDRAIL SYSTEM | LF | 50 | $0.00 | |||
| 0022 | 52 13 50 | FABRICATE AND INSTALL A SIDE OR BASE MOUNT GALVANIZED STEEL PIPE AND/OR TUBE GUARDRAIL SYSTEM | LF | 50 | $0.00 | |||
| 0023 | 05 05 10 | REMOVE AND DISPOSE OF PIPE AND/OR TUBE GUARDRAIL SYSTEM | LF | 50 | $0.00 | |||
| 06 10 00 | DIVISION 6-ROUGH CARPENTRY | |||||||
| 0024 | 05 05 10,11 10 02 | REMOVE AND REPLACE EXISTING WOOD BLOCKING, NAILER, OR FRAMING, NOMINAL 2" THICK | LF | 500 | $0.00 | |||
| 0025 | 05 05 10, 11 10 30 | REMOVE AND REPLACE EXISTING WOOD FASCIA BOARDS, NOMINAL 2" THICK | LF | 250 | $0.00 | |||
| 0026 | 05 05 10, 22 13 50 | REMOVE AND REPLACE EXISTING HARDBOARD SOFFIT (3/8") | SF | 100 | $0.00 | |||
| 0027 | FURNISH AND INSTALL PRESERVATIVE TREATED WOOD ROOF NAILERS, WHICH INCLUDES WOOD SADDLES OR CRICKETS, CANT STRIPS, CURBS FOR SCUTTLES AND VENTILATORS, AND WOOD NAILERS BOLTED TO TOPS OF CONCRETE OR MASONRY CURBS AND AT EXPANSION JOINTS | BF | 500 | $0.00 | ||||
| 0028 | 05 05 10,06 33 10 | REMOVE AND REPLACE 3/8", 5/8"OR 3/4" PLYWOOD ROOF SHEATHING or SOFFIT | SF | 200 | $0.00 | |||
| 0029 | 05 05 10, 16 33 10 | REMOVE AND REPLACE ROOF DECKING , WHICH INCLUDES 1x OR 2x DECKING | SF | 200 | $0.00 | |||
| 0030 | FURNISH AND INSTALL ROOFING LUMBER FOR RESIDENTIAL UNITS, WHICH INCLUDES RAFTERS, STUDS, PLATES, CAPS, COLLAR BEAMS, SLEEPERS, NAILING STRIPS, SILLS, HEADERS AND FASCIA | BF | 200 | $0.00 | ||||
| 7050510 | DIVISION 7 DEMO | |||||||
| 0031 | DEMOLITION, HAULING, AND DISPOSAL OF UP TO 5-PLY BURS WITH FLASHINGS, GRAVEL, ETC. (DOES NOT INCLUDE INSULATION) | SQ | 400 | $0.00 | ||||
| 0032 | DEMOLITION, HAULING, AND DISPOSAL OF INSULATION UP TO 2" THICK | SQ | 400 | $0.00 | ||||
| 0033 | DEMOLITION, HAULING, AND DISPOSAL OF INSULATION OVER 2" THICK | BF | 50 | $0.00 | ||||
| 0034 | REMOVE AND DISPOSE OF EXISTING ROOF SHINGLE SYSTEM AND UNDERLAYMENT, INCLUDING FLASHING AND DRIP EDGES | SQ | 30 | $0.00 | ||||
| 0035 | REMOVE AND DISPOSE OF EXISTING ROLL ROOFING AND UNDERLAYMENT, INCLUDING FLASHING AND DRIP EDGES | SQ | 10 | $0.00 | ||||
| 0036 | DEMOLITION, REMOVAL, AND DISPOSAL OF EXISTING METAL ROOFING SYSTEM | SQ | 100 | $0.00 | ||||
| 0037 | DEMOLITION, HAULING, AND DISPOSAL OF AGGREGATE BALLAST. INCLUDE SPUDDING BACK AND VACUUMING LOOSE AGGREGATE FROM ENTIRE ROOF SURFACE. | SQ | 50 | $0.00 | ||||
| 0038 | REMOVE SINGLE PLY ROOFING (INCLUDING PVC, EPDM, PIB, TPO AND OTHER MEMBRANE ROOFING) DOWN TO THE DECK. INCLUDE MEMBRANE, PENETRATION & WALL FLASHINGS AND MEMBRANE FASTENERS. NOT TO INCLUDE INSULATION, CRICKETS AND INSULATION FASTENERS. | SQ | 200 | $0.00 | ||||
| 0039 | 02 20 | FLASHING, SHEET METAL | SF | 200 | $0.00 | |||
| 0040 | 05 20 | BUILT-IN GUTTERS | LF | 100 | $0.00 | |||
| 0041 | 06 20 | WALL INSULATION, AIR/VAPOR BARRIER | SF | 100 | $0.00 | |||
| 0042 | 13 25 | PLUMBING VENT FLASHING | EA | 50 | $0.00 | |||
| 0043 | 13 75 | RIDGE VENT STRIP ALUMINUM | LF | 50 | $0.00 | |||
| 0044 | 21 20 | ROOF EDGE, ALUMINUM SOFFIT AND FASICA | LF | 200 | $0.00 | |||
| 0045 | 22 20 | DRIP EDGE | LF | 500 | $0.00 | |||
| 0046 | 22 70 | GRAVEL STOP | LF | 500 | $0.00 | |||
| 0047 | 23 70 | SHEET METAL COPING, UP TO 12" WIDE | LF | 200 | $0.00 | |||
| 0048 | 26 20 | ROOF VENTILATION, LOUVERED GABLE VENT | EA | 2 | $0.00 | |||
| 0049 | 26 70 | REMOVE ROOF HATCH | EA | 1 | $0.00 | |||
| 0050 | 26 75 | RAFTER VENTS | EA | 2 | $0.00 | |||
| 0051 | 27 20 | SOFFIT VENT AND/OR FASICA VENT | LF | 1 | $0.00 | |||
| 0052 | 27 25 | SOFFIT VENT STRIP,ALUMINUM,3" to 4" WIDE | LF | 20 | $0.00 | |||
| 0053 | 28 70 | CANT STRIP | LF | 50 | $0.00 | |||
| 0054 | 45 50 | ROOF HATCH | EA | 1 | $0.00 | |||
| 0055 | 49 70 | SIDING HORIZONTAL WOOD CLAPBOARDS | SF | 100 | $0.00 | |||
| 0056 | 50 25 | EXTERIOR INSULATION FINISH SYSTEMS (EIFS) | SF | 50 | $0.00 | |||
| 0057 | 58 80 | STEEL SIDING,CORRUGATED/RIBBED | SF | 1000 | $0.00 | |||
| 0058 | 59 20 | WATER PROVING, PROTECTION/DRAIN BOARD UP TO 1/2" | SF | 1000 | $0.00 | |||
| 07 22 16 | DIVISION 7-ROOF AND DECK INSULATION | |||||||
| POLYISOCYANURATE BOARD INSULATION | ||||||||
| 0059 | 17 05 | 1" THICK, R 5.7 | SF | 200 | $0.00 | |||
| 0060 | 17 15 | 1.5" THICK, R 8.6 | SF | 100 | $0.00 | |||
| 0061 | 17 25 | 2" THICK, R 11.4 | SF | 4,000 | $0.00 | |||
| 0062 | 17 45 | 3" THICK, R17.1 | SF | 200 | $0.00 | |||
| 0063 | 4" THICK, R22.8 | SF | 100 | $0.00 | ||||
| 0064 | 5" THICK, R28.5 | SF | 1,000 | $0.00 | ||||
| 0065 | 5.5" THICK, R31.3 | SF | 50 | $0.00 | ||||
| 0066 | 15 52 | 40 PSI EXTRUDED POLYSTYRENE 2" THICK R10 | SF | 4,000 | $0.00 | |||
| 0067 | 16 50 | EXPANDED PERLITE COVER BOARD 3/4" R2.08 | SF | 500 | $0.00 | |||
| 0068 | 16 60 | EXPANDED PERLITE COVER BOARD 1" R2.78 | SF | 100 | $0.00 | |||
| 0069 | 17 65 | TAPERED FILL INSULATION BOARD FOR DRAINAGE | BF | 5,000 | $0.00 | |||
| 07 22 00 | PROTECTION BOARDS: | |||||||
| 0070 | 7221610 | GLASS MAT GYPSUM ROOF BOARD | SF | 1000 | $0.00 | |||
| 0071 | 7221610 | HIGH DENSITY WOOD FIBER BOARD | SF | 1000 | $0.00 | |||
| 0072 | 7511330 | FIBER CANTS | LF | 250 | $0.00 | |||
| 0073 | 7511330 | WOOD CANTS | LF | 250 | $0.00 | |||
| 0074 | 7251010 | SHEATING PAPER FOR WOOD DECKS | SF | 5000 | $0.00 | |||
| 0075 | 07 21 16 | BATT ROOF INSULATION, R-19 | SF | 300 | $0.00 | |||
| 0076 | 07 21 16 | BATT ROOF INSULATION, R-30 | SF | 300 | $0.00 | |||
| 0077 | 1334195 | METAL ROOF INSULATION, VINYL FACED R30 | SQ | 100 | $0.00 | |||
| 07 24 13 | DIVISION 7-EXTERIOR INSULATION AND FINISH SYSTEMS | |||||||
| 0078 | 10 0105 | FIELD APPLIED 2" EPS INSULATION" | SF | 50 | $0.00 | |||
| 0079 | 10 0140 | PREMIUM FINISH ADD | SF | 50 | $0.00 | |||
| 0080 | 10 0150 | REINFORCING FABRIC | SF | 50 | $0.00 | |||
| 0081 | 10 0180 | COLOR OR TEXTURE CHANGE | SF | 50 | $0.00 | |||
| 0082 | 10 0190 | SUBSTRATE BASE LEVELING COAT | SF | 50 | $0.00 | |||
| 0083 | 10 0210 | SUBSTRATE SEALING COAT | SF | 50 | $0.00 | |||
| 0084 | 10 0437 | CRACK REPAIR 50 MIL, REINFORCED | SF | 20 | $0.00 | |||
| 07 31 13 | DIVISION 7-SHINGLE ROOFING SYSTEMS | |||||||
| 0085 | 10 0205 | FURNISH AND INSTALL NEW 3-TAB MINERAL SURFACED ASPHALT STRIP SHINGLE SYSTEM 30 YEAR PNEUMATIC NAILED | SQ | 10 | $0.00 | |||
| 0086 | 10 0505 | FURNISH AND INSTALL NEW ARCHITECTURAL DIMENSIONAL ASHPALT SHINGLE SYSTEM CLASS A 250- 270 LB/SQ 30 YR PNEUMATIC NAILED | SQ | 20 | $0.00 | |||
| 0087 | REMOVE AND REPLACE EXISTING SHINGLES WITH NEW ASPHALT STRIP SHINGLES TO MATCH ADJACENT AREAS, PARTIAL REPAIRS | SQ | 10 | $0.00 | ||||
| 0088 | ADD FOR STEEP ROOFS (7 TO 12 PITCH OR GREATER) | SQ | 10 | $0.00 | ||||
| DIVISION 7-STANDING SEAM METAL ROOF SYSTEM | ||||||||
| 0089 | 07 41 13 | NEW METAL ROOF PANELS, ARCHITECTURAL/NON-STRUCTURAL PER SPEC | SQ | 100 | $0.00 | |||
| 0090 | 07 61 14 | NEW STEEL STANDING SEAM METAL ROOFING, STRUCTURAL, PER SPEC. | SQ | 150 | $0.00 | |||
| 0091 | 07 61 15 | NEW ALUMINUM STANDING SEAM METAL ROOF, STRUCTURAL, PER SPEC. | SQ | 150 | $0.00 | |||
| 0092 | 07 71 19 | FASCIA PANEL SYSTEM | SF | 250 | $0.00 | |||
| 0093 | 07 46 73 | NON-PERFORATED SOFFIT PANEL | SF | 150 | $0.00 | |||
| 0094 | 07 46 73 | PERFORATED SOFFIT PANEL | SF | 150 | $0.00 | |||
| 07 42 13 | DIVISION 7-METAL WALL PANELS | |||||||
| 0095 | 20 2760 | FURNISH AND INSTALL METAL WALL PANELS | SF | 250 | $0.00 | |||
| 0096 | FURNISH AND INSTALL FABRICATED METAL WALL PANEL ASSEMBLY (INCLUDING INSULATION) | SF | 100 | $0.00 | ||||
| multiple | DIVISION 7-UNDERLAYMENT | |||||||
| 0097 | FELT, ASPHALT SATURATED, 30 POUND | SQ | 100 | $0.00 | ||||
| 0098 | SELF ADHERING LEAK BARRIER (PEAL AND STICK) | SQ | 100 | $0.00 | ||||
| 07 51 13 | DIVISION 7-BITUMINOUS ROOFING (BURS) | |||||||
| 0099 | 4-PLY BURS WITH SBS MODIFIED CAP SHEET | SQ | 400 | $0.00 | ||||
| 0100 | multiple | REMOVE AND REPLACE PITCH PAN | EA | 20 | $0.00 | |||
| FOR RESIDENTIAL UNITS | ||||||||
| 0101 | SINGLE-PLY SBS MODIFIED CAP SHEET FOR RESIDENTIAL UNITS | SQ | 10 | $0.00 | ||||
| 07 01 50 | DIVISION 7-PARTIAL BURS REPAIRS | |||||||
| 0102 | REPAIRS BLISTERS | SF | 500 | $0.00 | ||||
| 0103 | REPAIR SPLITS | LF | 200 | $0.00 | ||||
| 0104 | REPAIR RIDGES | LF | 200 | $0.00 | ||||
| 0105 | APPLY RESATURANT AND INSTALL NEW AGGREGATE ON EXPOSED FELT AREAS | SF | 500 | $0.00 | ||||
| 07 31 13 | DIVISION 7-PREPARED ROLL ROOFING | |||||||
| 0106 | FURNISH AND INSTALL NEW MINERAL SURFACED ASPHALT PREPARED ROLL ROOFING | SQ | 50 | $0.00 | ||||
| 0107 | CUT-OUT AND PATCH ROLL ROOFING | SQ | 5 | $0.00 | ||||
| multiple | DIVISION 7-TRAFFIC-BEARING ROOF DECK SURFACING | |||||||
| 0108 | 07 51 13 | TRAFFIC-BEARING ROOF SURFACING SYSTEM | SQ | 5 | $0.00 | |||
| 07 54 19 | DIVISION 7-SBS MODIFIED BITUMINOUS MEMBRANE | |||||||
| 0109 | 10 8850 | FURNISH/INSTALL MOD.BIT.RFNG.,SBS GRAN SURF.CAP SHEET, POLY.REINF | SF | 1000 | $0.00 | |||
| 0110 | FURNISH/INSTALL HEAVYWEIGHT BASE/PLY SHEET, REINFORCED, 87 to 90 MIL THICK | SF | 2000 | $0.00 | ||||
| 0111 | 10 8800 | FURNISH/INSTALL GRANULAR SURFACE FLASHING, 160 MIL | SF | 500 | $0.00 | |||
| 0112 | 10 8800 | FURNISH/INSTALL COLD PROCESS AHESIVE, 20 to 30 MIL THICK | SF | 3500 | $0.00 | |||
| 0113 | 10 2050 | HEAT WELD SEAMS | LF | 100 | $0.00 | |||
| 07 53 23 | DIVISION 7 ETHYLENE-PROPYLENE-DIEN-MONOMER ROOFING (EPDM) | |||||||
| 0114 | 3700 | FURNISH/INSTALL MECHANICALLY ATTACHED EPDM, 45 MIL,0.28 PSF | SQ | 10 | $0.00 | |||
| 0115 | 3800 | FURNISH/INSTALL FULLY ADHERED WITH ADHESIVE EPDM, 45 MIL,0.28 PSF PVC SYSTEM- 72 MILS | SQ | 10 | $0.00 | |||
| 0116 | 4700 | FURNISH/INSTALL MECHANICALLY ATTACHED EPDM, 60 MIL,0.40 PSF | SQ | 10 | $0.00 | |||
| 0117 | 4800 | FURNISH/INSTALL FULLY ADHERED WITH ADHESIVE EPDM, 60 MIL,0.40 PSF | SQ | 10 | $0.00 | |||
| 0118 | 4850 | SEAM TAPE FOR MEMBRANE 3" x 100' ROLL | EA | 5 | $0.00 | |||
| 0119 | 4900 | BATTEN STRIPS 10' SECTIONS | EA | 10 | $0.00 | |||
| 0120 | 4910 | COVER TAPE for BATTEN STRIPS 6" x 100' ROLL | EA | 10 | $0.00 | |||
| 0121 | 4970 | ADHESIVE FOR FULLY ADHERED SYSTEMS, 60 SF/GAL | GAL | 5 | $0.00 | |||
| 07 54 19 | DIVISION 7-POLYVINYL-CHLORIDE ROOFING | |||||||
| 0122 | 8850 | FURNISH/INSTALL FULLY ADHERED PVC SYSTEM- 72 MILS | SQ | 10 | $0.00 | |||
| 0123 | 8800 | FURNISH/INSTALL MECHANICALLY FASTENED PVC SYSTEM- 72 MIL | SQ | 10 | $0.00 | |||
| 0124 | PVC LAMINATED METAL FLASHING UP TO 18" STRETCH OUT | LF | 50 | $0.00 | ||||
| 0125 | PVC LAMINATED METAL FLASHING 18.1" TO 36" STRETCH OUT | LF | 50 | $0.00 | ||||
| 0126 | PVC VENT BOOTS | EA | 20 | $0.00 | ||||
| 0127 | PVC UNIVERSAL CORNERS | EA | 50 | $0.00 | ||||
| 0128 | PATCH AND REPAIR PVC SYSTEM | SF | 5 | $0.00 | ||||
| 07 14 00 | DIVISION 7-FLUID APPLIED WATERPROOFING | |||||||
| 0129 | FLUID APPLIED COATING SYSTEM FOR METAL ROOFS | SQ | 5 | $0.00 | ||||
| 0130 | ENERGY STAR RATED COATING SYSTEM APPLIED TO NEW BUR ROOFING WITH MODIFIED CAP SHEET | SQ | 5 | $0.00 | ||||
| 0131 | 07 56 10 | ELASTOMERIC COATING FOR ROOF REPAIRS | SQ | 5 | $0.00 | |||
| 07 71 19 | DIVISION 7-SHEET METAL WORK, GENERAL | |||||||
| FURNISH AND INSTALL NEW GRAVEL GUARD/FASCIA (FACE DIMENSION) | ||||||||
| 0132 | GALVANIZED METAL, 4"- 5" | LF | 200 | $0.00 | ||||
| 0133 | GALVANIZED METAL, 6" - 7" | LF | 100 | $0.00 | ||||
| 0134 | ALUMINUM, 4" - 5" | LF | 200 | $0.00 | ||||
| 0135 | ALUMINUM, 6" - 7" | LF | 100 | $0.00 | ||||
| 0136 | 2-PIECE GALVANIZED METAL, 7" - 10" | LF | 50 | $0.00 | ||||
| 0137 | 2-PIECE GALVANIZED METAL, 10" - 12" | LF | 50 | $0.00 | ||||
| 0138 | 2-PIECE ALUMINUM, 7" - 10" | LF | 50 | $0.00 | ||||
| 0139 | 2-PIECE ALUMINUM, 10" - 12" | LF | 50 | $0.00 | ||||
| FURNISH AND INSTALL: | ||||||||
| 0140 | GALVANIZED METAL DRIP EDGE | LF | 250 | $0.00 | ||||
| 0141 | GALVANIZED METAL COUNTERFLASHING | SF | 150 | $0.00 | ||||
| 0142 | 07 65 10 | GALVANIZED METAL VALLEY FLASHING | SF | 150 | $0.00 | |||
| 0143 | GALVANIZED METAL STEP FLASHING | SF | 100 | $0.00 | ||||
| 0144 | GALVANIZED METAL BASE FLASHING | SF | 100 | $0.00 | ||||
| 0145 | GALVANIZED METAL FLASHING- FLAT SHEET | SF | 100 | $0.00 | ||||
| 0146 | GALVANIZED METAL CAP FLASHING | SF | 100 | $0.00 | ||||
| 0147 | 07 71 43 | ALUMINUM DRIP EDGE | LF | 250 | $0.00 | |||
| 0148 | ALUMINUM COUNTERFLASHING | SF | 150 | $0.00 | ||||
| 0149 | ALUMINUM VALLEY FLASHING | SF | 200 | $0.00 | ||||
| 0150 | ALUMINUM STEP FLASHING | SF | 100 | $0.00 | ||||
| 0151 | ALUMINUM BASE FLASHING | SF | 100 | $0.00 | ||||
| 0152 | ALUMINUM FLASHING - FLAT SHEET | SF | 100 | $0.00 | ||||
| 0153 | 04 72 10 | ALUMINUM CAP FLASHING | SF | 100 | $0.00 | |||
| 0154 | METAL RIDGE VENT | LF | 100 | $0.00 | ||||
| REMOVE EXISTING EXPANSION JOINT AND INSTALL NEW EXPANSION JOINT: | ||||||||
| 0155 | 07 71 29 | ELASTOMERIC TYPE (NEOPRENE BELLOWS) | LF | 50 | $0.00 | |||
| 0156 | 2500 | ALUMINUM CAPPED CURB | LF | 50 | $0.00 | |||
| 0157 | GALVANIZED CAPPED CURB | LF | 50 | $0.00 | ||||
| 0158 | REMOVE AND REPLACE VENTILATOR, ROOFTOP | EA | 1 | $0.00 | ||||
| 0159 | REMOVE AND REPLACE VENTILATOR, RIDGE | LF | 20 | $0.00 | ||||
| 0160 | REMOVE AND REPLACE VENTILATOR, GABLE | EA | 2 | $0.00 | ||||
| 0161 | REMOVE AND REPLACE CURB ASSEMBLY, METAL WITH CRICKET, FACTORY FABRICATED AND FINISHED | EA | 2 | $0.00 | ||||
| 0162 | REMOVE AND REPLACE ROOF SCUTTLE | EA | 2 | $0.00 | ||||
| 07 71 23 | DIVISION 7-GUTTERS AND DOWNSPOUTS | |||||||
| 0163 | 01 20 | REMOVE EXISTING GUTTER AND DOWNSPOUTS, INCLUDING HANGERS | LF | 500 | $0.00 | |||
| FURNISH AND INSTALL NEW GUTTER, BOX, INCLUDING HANGARS, BRACKETS, SEALANTS, ETC. | ||||||||
| 0164 | 24 GA. GALVANIZED/PRIMED, 4" X 5" | LF | 100 | $0.00 | ||||
| 0165 | 24 GA. GALVANIZED/PRIMED, 5" X 7" | LF | 250 | $0.00 | ||||
| 0166 | ALUMINUM, 4" X 5" | LF | 250 | $0.00 | ||||
| 0167 | ALUMINUM, 5" X 7" | LF | 100 | $0.00 | ||||
| 07 71 23 | FURNISH & INSTALL NEW DOWNSPOUTS, INCLUDES BRACKETS, ETC. | |||||||
| 0168 | 24 GA. GALVANIZED/PRIMED, 3" X 4" | LF | 200 | $0.00 | ||||
| 0169 | ALUMINUM, 3" X 4" | LF | 100 | $0.00 | ||||
| 0170 | FURNISH & INSTALL NEW PRE-FORMED CONCRETE SPLASHBLOCKS | EA | 20 | $0.00 | ||||
| 0171 | FURNISH AND INSTALL NEW THROUGH WALL SCUPPERS | EA | 10 | $0.00 | ||||
| FURNISH AND INSTALL CONDUCTOR HEAD | EA | 2 | $0.00 | |||||
| 05 40 00 | DIVISION 7-MANUFACTURED ROOF FRAMING SYSTEM | |||||||
| 0172 | RETROFIT ROOFING & STRUCTURAL-UP TO 6/12 SLOPE <= 100 SQ | SQ | 10 | $0.00 | ||||
| 0173 | RETROFIT ROOFING & STRUCTURAL-UP TO 6/12 SLOPE =>100 SQ | SQ | 10 | $0.00 | ||||
| 07 92 00 | DIVISION 7-CAULKING AND SEALANTS | |||||||
| 0174 | REMOVE EXISTING CAULKING, CLEAN JOINT | LF | 500 | $0.00 | ||||
| 0175 | SILICONE CAULKING/SEALANT | LF | 250 | $0.00 | ||||
| 0176 | CAULKING, MISCELLANEOUS APPLICATION (SONNEBORN, SONOLASTIC NP-1, OR APPROVED EQUAL) | LF | 250 | $0.00 | ||||
| 08 05 05 | DIVISION 8 COMMON WORK RESULTS for OPENINGS | |||||||
| 0177 | 05 05 20 | REMOVE SHYLIGHTS, PLSTC DOMES, FLUSH CURB MTD | SF | 100 | $0.00 | |||
| 0178 | 62 13 20 | SKY LIGHTS FLUSH OR CURB MOUNTED VENTILATiING INSULATED PLEXIGLASS DOME | EA | 2 | $0.00 | |||
| 09 90 00 | DIVISION 9-PAINTING | |||||||
| 0179 | PAINT, BASE SCHEME, EXT. LATEX, 1 COAT | SF | 200 | $0.00 | ||||
| 0180 | PAINT, BASE SCHEME, EXT. LATEX, PRIMER AND 2 COATS | SF | 200 | $0.00 | ||||
| 22 00 00 | DIVISION 15-ROOF DRAINS | |||||||
| 0181 | REFLASH EXISTING ROOF DRAIN, INCLUDES NEW LEAD FLASHING, CLAMPING RING, AND CAST IRON DOME STRAINER | EA | 3 | $0.00 | ||||
| 0182 | REMOVE AND REPLACE EXISTING ROOF DRAIN, INCLUDES NEW CAST IRON DOME STRAINER | EA | 6 | $0.00 | ||||
| 26 41 00 | DIVISION 16-LIGHTING PROTECTION | |||||||
| REMOVE EXISTING LIGHTNING PROTECTION SYSTEM AND REINSTALL EXISTING LIGHTNING PROTECTION SYSTEM WITH NEW FASTENERS | ||||||||
| 0183 | REMOVE AND REINSTALL EXISTING CONDUCTOR | LF | 50 | $0.00 | ||||
| 0184 | REMOVE AND INSTALL NEW FASTENERS, INCLUDING LOOPS AND CLIPS | EA | 10 | $0.00 | ||||
| REMOVE EXISTING LIGHTNING PROTECTION SYSTEM AND INSTALL NEW LIGHTNING PROTECTION SYSTEM | ||||||||
| 0185 | AIR TERMINALS, INCLUDES COPPER BASE FOR NON-METAL ROOFS | EA | 10 | $0.00 | ||||
| 0186 | AIR TERMINALS, INCLUDES ALUMINUM BASE FOR METAL ROOFS | EA | 10 | $0.00 | ||||
| 0187 | CONDUCTORS | LF | 100 | $0.00 | ||||
| 0188 | FASTENERS, INCLUDES LOOPS AND CLIPS | EA | 30 | $0.00 | ||||
| 0189 | CONNECTORS | EA | 5 | $0.00 | ||||
| 0190 | COUNTERPOISE CONDUCTOR | LF | 300 | $0.00 | ||||
| 0191 | GROUNDING RODS, 3/4" DIAMETER x 60' LONG | EA | 3 | $0.00 | ||||
| 0192 | SURGE PROTECTION | EA | 1 | $0.00 | ||||
| 0193 | FURNISH AND INSTALL GROUND ACCESS PVC TEST WELL, 12" I.D. X 24" LONG WITH 1/4" GALVANIZED FRICTION FIT COVER WITH THE WORD "GROUND" ENGREAVED ON TOP OF THE COVER | EA | 1 | $0.00 | ||||
| 0194 | UL SITE INSPECTION | EA | 1 | $0.00 | ||||
| MISCELLANEOUS ROOFING ITEMS | ||||||||
| 0195 | FURNISH AND INSTALL PERMANENT FALL PROTECTION ANCHORAGE (PER EACH ANCHOR POINT) | EA | 24 | $0.00 | ||||
| 0196 | DESIGN, PROVIDE AND INSTALL FLEXIBLE LIFE LINE FALL ARREST PROTECTION SYSTEM AROUND PERIMETER and NEAR RIGE CAPS. FALL PROTECTION NEEDS TO BE SURFACE MOUNTED TO METAL ROOFS (GRADE 316 STAINLESS STEEL 5/16" DIAMETER WIRE WITH BRACKETS) SYSTEM MUST BE CAPABLE TO SUPPORT UP TO THREE PEOPLE | LF | 800 | $0.00 | ||||
| 0197 | EXTEND PLUMBING VENTS | LF | 10 | $0.00 | ||||
| 0198 | FLEXIBLE VENT PIPE FLASHING (METAL ROOFS) | EA | 10 | $0.00 | ||||
| 0199 | REMOVE AND REPLACE LEAD FLASHING AT VENT THRU ROOF (VTR) | EA | 10 | $0.00 | ||||
| 0200 | REMOVE EXISTING VTR PENETRATION FLASHING AND REPLACE WITH COLLAR TYPE FLASHING | EA | 10 | $0.00 | ||||
| 0201 | REPAIR AND REPLACE SPALLS, HOLES, AND CRACKS IN EXISTING CONCRETE ROOF DECK | SF | 50 | $0.00 | ||||
| 0202 | FURNISH AND INSTALL VAPOR BARRIER OVER CONCRETE DECKS | SQ | 4 | $0.00 | ||||
| 0203 | DISCONNECT AND RECONNECT ELECTRICAL SERVICE (<200 AMP) | EA | 3 | $0.00 | ||||
| 0204 | REMOVE EXISTING CONDUIT, ETC. AND REPLACE WITH NEW 3/4" RIGID CONDUIT, INCLUDING WIRE, BOXES, FITTINGS, ETC. | LF | 30 | $0.00 | ||||
| 0205 | ROLL COIL RIDGE VENT | LF | 30 | $0.00 | ||||
| 0206 | SPUD EXISTING ROOF TO INSULATION | SQ | 50 | $0.00 | ||||
| 0207 | CUT AND PATCH CONCRETE | LF | 100 | $0.00 | ||||
| 0208 | TRENCH AND BACKFILL | LF | 100 | $0.00 | ||||
| 0209 | TESTING (CORE CUT) OF ROOFS-REPAIR TEST AREA | EA | 10 | $0.00 | ||||
| 0210 | MOISTURE INSPECTION BY THERMAL IMAGING SURVEY | SF | 1000 | $0.00 | ||||
| 0211 | AS-BUILT DRAWINGS PER SPEC. | JOB | 3 | $0.00 | ||||
| 0212 | ENGINEERING RATE STRUCTURAL | HR | 10 | $0.00 | ||||
| 0213 | ENGINEERING RATE STRUCTURAL - FALL PROTECTION | JOB | 20 | $0.00 | ||||
| 0214 | MECHANICAL SUBCONTRACTOR | HR | 10 | $0.00 | ||||
| 0215 | ELECTRICAL SUBCONTRACTOR | HR | 10 | $0.00 | ||||
| 0216 | LABOR RATE - MISCELLANEOUS WORK | MH | 100 | $0.00 | ||||
| SPECIAL CONDITIONS AND CIRCUMSTANCES | ||||||||
| 0217 | HEIGHT FACTOR, 30 FEET OR GREATER ABOVE GROUND, UNIT EACH=JOB | EA | 3 | $0.00 | ||||
| Subtotal | $0.00 | |||||||
| MODIFIERS | ||||||||
| 0218 | MULTIPLIER % TO BE ADDED TO TOTAL FOR URGENT TASK ORDER (UTO)/NON-STANDARD HOUR WORK-TEMPORARY DRY-IN WORK ONLY | % | 1 | $0.00 | ||||
| OPTION YEAR 1 | $0.00 |
&"Arial,Bold"&10Page &P of &N &"Arial,Bold"&10&A - &F
OPTION YEAR 2
| 13-Jul-18 | |
| ROOFING BID SCHEDULE | |
| IDIQ 2018-2022 | |
| Project No. CP# Master Spec |
| OPTION YEAR 2 | ESCALATION | TOTAL PRICE | Contractor | |||||
| 0.00 | ||||||||
| LINE ITEM | SPEC | DESCRIPTION | Unit | EST. QTY. | UNIT PRICE | EST. TOTAL PRICE | UNIT PRICE | EST. TOTAL PRICE |
| 02 41 00 | DIVISION2-SELECTIVE DEMOLITION | |||||||
| 0001 | 41 13 84 | REMOVE DEMO SPLASH BLOCKS | SF | 50 | $0.00 | |||
| DIVISION 2-ASBESTOS ABATEMENT/ LEAD CONTROLS | ||||||||
| 0002 | 02 82 13 | CLASS I AND/OR CLASS II ASBESTOS CONTAINING ROOF MATERIALS (ACRM) ROOF MEMBRANE | SF | 100 | $0.00 | |||
| 0003 | 02 82 16 | CEMENTITIOUS ASBESTOS FIBER ROOF DECK/FORM BOARD | SF | 50 | $0.00 | |||
| 0004 | 02 83 13 | LEAD CONTROLS | SF | 50 | $0.00 | |||
| 0005 | 04 01 20 | DIVISION 4-MASONRY | ||||||
| 0006 | 01 02 20 | CONCRETE MASONRY UNITS TO INCLUDE GROUTING, TUCK POINTING, FORMWORK, AND SUPPORTS. PERFORM WORK IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. | SF | 100 | $0.00 | |||
| 0007 | 01 30 20 | WATER BLAST CLEAN EXISTING MASONRY SURFACE IN ACCOURDANCE WITH PAINT MANUFACTURER'S RECOMMENDATIONS. | SF | 100 | $0.00 | |||
| 05 05 05 | DIVISION 5-STEEL ROOF DECK | |||||||
| 0008 | 05 05 10 | REMOVE EXISTING STEEL ROOF DECK AND REPLACE WITH NEW STEEL ROOF DECK | SQ | 10 | $0.00 | |||
| 0009 | 05 05 10 | DEMO LADDER WITH CAGE | VLF | 20 | $0.00 | |||
| 0010 | 05 05 10 | DEMO LADDER WITHOUT CAGE | VLF | 20 | $0.00 | |||
| 0011 | DIVISION 5-METALS | |||||||
| 0012 | 05 40 00 | COLD-FORMED METAL FRAMING | ||||||
| 0013 | 42 23 70 | COLD-FORMED METAL FRAMING MEMBERS OR SOFFIT FRAMING, TO INCLUDE SADDLES, CANT STRIPS, CURBS FOR SCUTTLES AND VENTILATORS, AND NAILERS ATTACHED AT THE TOPS OF CONCRETE OR MASONRY CURBS, EXPANSION JOINTS AND ROOF EDGES. FRAMING MEMBERS ARE 4" TO 8" WIDE BY 18 GAUGE OR THINNER. | LF | 250 | $0.00 | |||
| 0014 | 12 23 78 | RETROFIT SUB-PURLIN AND/OR FORMED SHAPED FRAMING SYSTEM MECHANICALLY FASTENED TO EXISTING AND/OR SUBSTRATE IN ACCORDANCE WITH MANUFACTURES SPECIFICATIONS. MINIMUM 16 GAUGE THICKNESS | LF | 250 | $0.00 | |||
| 0015 | 05 50 13 | METAL FABRICATION | ||||||
| 0016 | SHOP PRIMED STEEL MATERIALS INCLUDING BUT NOT LIMITED TO: PLATES, ANGLES, ANCHOR BOLTS, STEEL PIPE SLEEVES, WEDGE TYPE INSERTS, EXPANSION ANCHORS, FRAMING, SUPPORTS AND FABRICATED ITEMS FOR APPLICATIONS THAT ARE NOT SPECIFIED IN OTHER SPECIFICATION SECTIONS. | LB | 200 | $0.00 | ||||
| 0017 | 05 51 33 | STAIRS AND LADDERS | ||||||
| 0018 | 51 33 13 | FABRICATE AND INSTALL ALUMINUM ROOF ACCESS STAIRS OR LADDERS WITH CAGE | VLF | 10 | $0.00 | |||
| 0019 | 51 33 13 | FABRICATE AND INSTALL GALVANIZED STEEL ROOF ACCESS STAIRS OR LADDERS WITH CAGE | VLF | 10 | $0.00 | |||
| 0020 | 05 52 00 | PIPE AND TUBE RAILINGS | ||||||
| 0021 | 52 13 50 | FABRICATE AND INSTALL A SIDE OR BASE MOUNT ALUMINUM PIPE AND/OR TUBE GUARDRAIL SYSTEM | LF | 50 | $0.00 | |||
| 0022 | 52 13 50 | FABRICATE AND INSTALL A SIDE OR BASE MOUNT GALVANIZED STEEL PIPE AND/OR TUBE GUARDRAIL SYSTEM | LF | 50 | $0.00 | |||
| 0023 | 05 05 10 | REMOVE AND DISPOSE OF PIPE AND/OR TUBE GUARDRAIL SYSTEM | LF | 50 | $0.00 | |||
| 06 10 00 | DIVISION 6-ROUGH CARPENTRY | |||||||
| 0024 | 05 05 10,11 10 02 | REMOVE AND REPLACE EXISTING WOOD BLOCKING, NAILER, OR FRAMING, NOMINAL 2" THICK | LF | 500 | $0.00 | |||
| 0025 | 05 05 10, 11 10 30 | REMOVE AND REPLACE EXISTING WOOD FASCIA BOARDS, NOMINAL 2" THICK | LF | 250 | $0.00 | |||
| 0026 | 05 05 10, 22 13 50 | REMOVE AND REPLACE EXISTING HARDBOARD SOFFIT (3/8") | SF | 100 | $0.00 | |||
| 0027 | FURNISH AND INSTALL PRESERVATIVE TREATED WOOD ROOF NAILERS, WHICH INCLUDES WOOD SADDLES OR CRICKETS, CANT STRIPS, CURBS FOR SCUTTLES AND VENTILATORS, AND WOOD NAILERS BOLTED TO TOPS OF CONCRETE OR MASONRY CURBS AND AT EXPANSION JOINTS | BF | 500 | $0.00 | ||||
| 0028 | 05 05 10,06 33 10 | REMOVE AND REPLACE 3/8", 5/8"OR 3/4" PLYWOOD ROOF SHEATHING or SOFFIT | SF | 200 | $0.00 | |||
| 0029 | 05 05 10, 16 33 10 | REMOVE AND REPLACE ROOF DECKING , WHICH INCLUDES 1x OR 2x DECKING | SF | 200 | $0.00 | |||
| 0030 | FURNISH AND INSTALL ROOFING LUMBER FOR RESIDENTIAL UNITS, WHICH INCLUDES RAFTERS, STUDS, PLATES, CAPS, COLLAR BEAMS, SLEEPERS, NAILING STRIPS, SILLS, HEADERS AND FASCIA | BF | 200 | $0.00 | ||||
| 7050510 | DIVISION 7 DEMO | |||||||
| 0031 | DEMOLITION, HAULING, AND DISPOSAL OF UP TO 5-PLY BURS WITH FLASHINGS, GRAVEL, ETC. (DOES NOT INCLUDE INSULATION) | SQ | 400 | $0.00 | ||||
| 0032 | DEMOLITION, HAULING, AND DISPOSAL OF INSULATION UP TO 2" THICK | SQ | 400 | $0.00 | ||||
| 0033 | DEMOLITION, HAULING, AND DISPOSAL OF INSULATION OVER 2" THICK | BF | 50 | $0.00 | ||||
| 0034 | REMOVE AND DISPOSE OF EXISTING ROOF SHINGLE SYSTEM AND UNDERLAYMENT, INCLUDING FLASHING AND DRIP EDGES | SQ | 30 | $0.00 | ||||
| 0035 | REMOVE AND DISPOSE OF EXISTING ROLL ROOFING AND UNDERLAYMENT, INCLUDING FLASHING AND DRIP EDGES | SQ | 10 | $0.00 | ||||
| 0036 | DEMOLITION, REMOVAL, AND DISPOSAL OF EXISTING METAL ROOFING SYSTEM | SQ | 100 | $0.00 | ||||
| 0037 | DEMOLITION, HAULING, AND DISPOSAL OF AGGREGATE BALLAST. INCLUDE SPUDDING BACK AND VACUUMING LOOSE AGGREGATE FROM ENTIRE ROOF SURFACE. | SQ | 50 | $0.00 | ||||
| 0038 | REMOVE SINGLE PLY ROOFING (INCLUDING PVC, EPDM, PIB, TPO AND OTHER MEMBRANE ROOFING) DOWN TO THE DECK. INCLUDE MEMBRANE, PENETRATION & WALL FLASHINGS AND MEMBRANE FASTENERS. NOT TO INCLUDE INSULATION, CRICKETS AND INSULATION FASTENERS. | SQ | 200 | $0.00 | ||||
| 0039 | 02 20 | FLASHING, SHEET METAL | SF | 200 | $0.00 | |||
| 0040 | 05 20 | BUILT-IN GUTTERS | LF | 100 | $0.00 | |||
| 0041 | 06 20 | WALL INSULATION, AIR/VAPOR BARRIER | SF | 100 | $0.00 | |||
| 0042 | 13 25 | PLUMBING VENT FLASHING | EA | 50 | $0.00 | |||
| 0043 | 13 75 | RIDGE VENT STRIP ALUMINUM | LF | 50 | $0.00 | |||
| 0044 | 21 20 | ROOF EDGE, ALUMINUM SOFFIT AND FASICA | LF | 200 | $0.00 | |||
| 0045 | 22 20 | DRIP EDGE | LF | 500 | $0.00 | |||
| 0046 | 22 70 | GRAVEL STOP | LF | 500 | $0.00 | |||
| 0047 | 23 70 | SHEET METAL COPING, UP TO 12" WIDE | LF | 200 | $0.00 | |||
| 0048 | 26 20 | ROOF VENTILATION, LOUVERED GABLE VENT | EA | 1 | $0.00 | |||
| 0049 | 26 70 | REMOVE ROOF HATCH | EA | 1 | $0.00 | |||
| 0050 | 26 75 | RAFTER VENTS | EA | 2 | $0.00 | |||
| 0051 | 27 20 | SOFFIT VENT AND/OR FASICA VENT | LF | 1 | $0.00 | |||
| 0052 | 27 25 | SOFFIT VENT STRIP,ALUMINUM,3" to 4" WIDE | LF | 20 | $0.00 | |||
| 0053 | 28 70 | CANT STRIP | LF | 50 | $0.00 | |||
| 0054 | 45 50 | ROOF HATCH | EA | 1 | $0.00 | |||
| 0055 | 49 70 | SIDING HORIZONTAL WOOD CLAPBOARDS | SF | 100 | $0.00 | |||
| 0056 | 50 25 | EXTERIOR INSULATION FINISH SYSTEMS (EIFS) | SF | 50 | $0.00 | |||
| 0057 | 58 80 | STEEL SIDING,CORRUGATED/RIBBED | SF | 1000 | $0.00 | |||
| 0058 | 59 20 | WATER PROVING, PROTECTION/DRAIN BOARD UP TO 1/2" | SF | 1000 | $0.00 | |||
| 07 22 16 | DIVISION 7-ROOF AND DECK INSULATION | |||||||
| POLYISOCYANURATE BOARD INSULATION | ||||||||
| 0059 | 17 05 | 1" THICK, R 5.7 | SF | 200 | $0.00 | |||
| 0060 | 17 15 | 1.5" THICK, R 8.6 | SF | 100 | $0.00 | |||
| 0061 | 17 25 | 2" THICK, R 11.4 | SF | 200 | $0.00 | |||
| 0062 | 17 45 | 3" THICK, R17.1 | SF | 200 | $0.00 | |||
| 0063 | 4" THICK, R22.8 | SF | 100 | $0.00 | ||||
| 0064 | 5" THICK, R28.5 | SF | 1,000 | $0.00 | ||||
| 0065 | 5.5" THICK, R31.3 | SF | 50 | $0.00 | ||||
| 0066 | 15 52 | 40 PSI EXTRUDED POLYSTYRENE 2" THICK R10 | SF | 200 | $0.00 | |||
| 0067 | 16 50 | EXPANDED PERLITE COVER BOARD 3/4" R2.08 | SF | 500 | $0.00 | |||
| 0068 | 16 60 | EXPANDED PERLITE COVER BOARD 1" R2.78 | SF | 100 | $0.00 | |||
| 0069 | 17 65 | TAPERED FILL INSULATION BOARD FOR DRAINAGE | BF | 5,000 | $0.00 | |||
| 07 22 00 | PROTECTION BOARDS: | |||||||
| 0070 | 7221610 | GLASS MAT GYPSUM ROOF BOARD | SF | 1000 | $0.00 | |||
| 0071 | 7221610 | HIGH DENSITY WOOD FIBER BOARD | SF | 1000 | $0.00 | |||
| 0072 | 7511330 | FIBER CANTS | LF | 250 | $0.00 | |||
| 0073 | 7511330 | WOOD CANTS | LF | 250 | $0.00 | |||
| 0074 | 7251010 | SHEATING PAPER FOR WOOD DECKS | SF | 5000 | $0.00 | |||
| 0075 | 07 21 16 | BATT ROOF INSULATION, R-19 | SF | 300 | $0.00 | |||
| 0076 | 07 21 16 | BATT ROOF INSULATION, R-30 | SF | 300 | $0.00 | |||
| 0077 | 1334195 | METAL ROOF INSULATION, VINYL FACED R30 | SQ | 100 | $0.00 | |||
| 07 24 13 | DIVISION 7-EXTERIOR INSULATION AND FINISH SYSTEMS | |||||||
| 0078 | 10 0105 | FIELD APPLIED 2" EPS INSULATION" | SF | 50 | $0.00 | |||
| 0079 | 10 0140 | PREMIUM FINISH ADD | SF | 50 | $0.00 | |||
| 0080 | 10 0150 | REINFORCING FABRIC | SF | 50 | $0.00 | |||
| 0081 | 10 0180 | COLOR OR TEXTURE CHANGE | SF | 50 | $0.00 | |||
| 0082 | 10 0190 | SUBSTRATE BASE LEVELING COAT | SF | 50 | $0.00 | |||
| 0083 | 10 0210 | SUBSTRATE SEALING COAT | SF | 50 | $0.00 | |||
| 0084 | 10 0437 | CRACK REPAIR 50 MIL, REINFORCED | SF | 20 | $0.00 | |||
| 07 31 13 | DIVISION 7-SHINGLE ROOFING SYSTEMS | |||||||
| 0085 | 10 0205 | FURNISH AND INSTALL NEW 3-TAB MINERAL SURFACED ASPHALT STRIP SHINGLE SYSTEM 30 YEAR PNEUMATIC NAILED | SQ | 10 | $0.00 | |||
| 0086 | 10 0505 | FURNISH AND INSTALL NEW ARCHITECTURAL DIMENSIONAL ASHPALT SHINGLE SYSTEM CLASS A 250- 270 LB/SQ 30 YR PNEUMATIC NAILED | SQ | 20 | $0.00 | |||
| 0087 | REMOVE AND REPLACE EXISTING SHINGLES WITH NEW ASPHALT STRIP SHINGLES TO MATCH ADJACENT AREAS, PARTIAL REPAIRS | SQ | 10 | $0.00 | ||||
| 0088 | ADD FOR STEEP ROOFS (7 TO 12 PITCH OR GREATER) | SQ | 10 | $0.00 | ||||
| DIVISION 7-STANDING SEAM METAL ROOF SYSTEM | ||||||||
| 0089 | 07 41 13 | NEW METAL ROOF PANELS, ARCHITECTURAL/NON-STRUCTURAL PER SPEC | SQ | 100 | $0.00 | |||
| 0090 | 07 61 14 | NEW STEEL STANDING SEAM METAL ROOFING, STRUCTURAL, PER SPEC. | SQ | 150 | $0.00 | |||
| 0091 | 07 61 15 | NEW ALUMINUM STANDING SEAM METAL ROOF, STRUCTURAL, PER SPEC. | SQ | 150 | $0.00 | |||
| 0092 | 07 71 19 | FASCIA PANEL SYSTEM | SF | 250 | $0.00 | |||
| 0093 | 07 46 73 | NON-PERFORATED SOFFIT PANEL | SF | 150 | $0.00 | |||
| 0094 | 07 46 73 | PERFORATED SOFFIT PANEL | SF | 150 | $0.00 | |||
| 07 42 13 | DIVISION 7-METAL WALL PANELS | |||||||
| 0095 | 20 2760 | FURNISH AND INSTALL METAL WALL PANELS | SF | 250 | $0.00 | |||
| 0096 | FURNISH AND INSTALL FABRICATED METAL WALL PANEL ASSEMBLY (INCLUDING INSULATION) | SF | 100 | $0.00 | ||||
| multiple | DIVISION 7-UNDERLAYMENT | |||||||
| 0097 | FELT, ASPHALT SATURATED, 30 POUND | SQ | 100 | $0.00 | ||||
| 0098 | SELF ADHERING LEAK BARRIER (PEAL AND STICK) | SQ | 100 | $0.00 | ||||
| 07 51 13 | DIVISION 7-BITUMINOUS ROOFING (BURS) | |||||||
| 0099 | 4-PLY BURS WITH SBS MODIFIED CAP SHEET | SQ | 400 | $0.00 | ||||
| 0100 | multiple | REMOVE AND REPLACE PITCH PAN | EA | 20 | $0.00 | |||
| FOR RESIDENTIAL UNITS | ||||||||
| 0101 | SINGLE-PLY SBS MODIFIED CAP SHEET FOR RESIDENTIAL UNITS | SQ | 10 | $0.00 | ||||
| 07 01 50 | DIVISION 7-PARTIAL BURS REPAIRS | |||||||
| 0102 | REPAIRS BLISTERS | SF | 500 | $0.00 | ||||
| 0103 | REPAIR SPLITS | LF | 200 | $0.00 | ||||
| 0104 | REPAIR RIDGES | LF | 200 | $0.00 | ||||
| 0105 | APPLY RESATURANT AND INSTALL NEW AGGREGATE ON EXPOSED FELT AREAS | SF | 500 | $0.00 | ||||
| 07 31 13 | DIVISION 7-PREPARED ROLL ROOFING | |||||||
| 0106 | FURNISH AND INSTALL NEW MINERAL SURFACED ASPHALT PREPARED ROLL ROOFING | SQ | 50 | $0.00 | ||||
| 0107 | CUT-OUT AND PATCH ROLL ROOFING | SQ | 5 | $0.00 | ||||
| multiple | DIVISION 7-TRAFFIC-BEARING ROOF DECK SURFACING | |||||||
| 0108 | 07 51 13 | TRAFFIC-BEARING ROOF SURFACING SYSTEM | SQ | 5 | $0.00 | |||
| 07 54 19 | DIVISION 7-SBS MODIFIED BITUMINOUS MEMBRANE | |||||||
| 0109 | 10 8850 | FURNISH/INSTALL MOD.BIT.RFNG.,SBS GRAN SURF.CAP SHEET, POLY.REINF | SF | 1000 | $0.00 | |||
| 0110 | FURNISH/INSTALL HEAVYWEIGHT BASE/PLY SHEET, REINFORCED, 87 to 90 MIL THICK | SF | 2000 | $0.00 | ||||
| 0111 | 10 8800 | FURNISH/INSTALL GRANULAR SURFACE FLASHING, 160 MIL | SF | 500 | $0.00 | |||
| 0112 | 10 8800 | FURNISH/INSTALL COLD PROCESS AHESIVE, 20 to 30 MIL THICK | SF | 3500 | $0.00 | |||
| 0113 | 10 2050 | HEAT WELD SEAMS | LF | 100 | $0.00 | |||
| 07 53 23 | DIVISION 7 ETHYLENE-PROPYLENE-DIEN-MONOMER ROOFING (EPDM) | |||||||
| 0114 | 3700 | FURNISH/INSTALL MECHANICALLY ATTACHED EPDM, 45 MIL,0.28 PSF | SQ | 10 | $0.00 | |||
| 0115 | 3800 | FURNISH/INSTALL FULLY ADHERED WITH ADHESIVE EPDM, 45 MIL,0.28 PSF PVC SYSTEM- 72 MILS | SQ | 10 | $0.00 | |||
| 0116 | 4700 | FURNISH/INSTALL MECHANICALLY ATTACHED EPDM, 60 MIL,0.40 PSF | SQ | 10 | $0.00 | |||
| 0117 | 4800 | FURNISH/INSTALL FULLY ADHERED WITH ADHESIVE EPDM, 60 MIL,0.40 PSF | SQ | 10 | $0.00 | |||
| 0118 | 4850 | SEAM TAPE FOR MEMBRANE 3" x 100' ROLL | EA | 5 | $0.00 | |||
| 0119 | 4900 | BATTEN STRIPS 10' SECTIONS | EA | 10 | $0.00 | |||
| 0120 | 4910 | COVER TAPE for BATTEN STRIPS 6" x 100' ROLL | EA | 10 | $0.00 | |||
| 0121 | 4970 | ADHESIVE FOR FULLY ADHERED SYSTEMS, 60 SF/GAL | GAL | 5 | $0.00 | |||
| 07 54 19 | DIVISION 7-POLYVINYL-CHLORIDE ROOFING | |||||||
| 0122 | 8850 | FURNISH/INSTALL FULLY ADHERED PVC SYSTEM- 72 MILS | SQ | 10 | $0.00 | |||
| 0123 | 8800 | FURNISH/INSTALL MECHANICALLY FASTENED PVC SYSTEM- 72 MIL | SQ | 10 | $0.00 | |||
| 0124 | PVC LAMINATED METAL FLASHING UP TO 18" STRETCH OUT | LF | 50 | $0.00 | ||||
| 0125 | PVC LAMINATED METAL FLASHING 18.1" TO 36" STRETCH OUT | LF | 50 | $0.00 | ||||
| 0126 | PVC VENT BOOTS | EA | 20 | $0.00 | ||||
| 0127 | PVC UNIVERSAL CORNERS | EA | 50 | $0.00 | ||||
| 0128 | PATCH AND REPAIR PVC SYSTEM | SF | 5 | $0.00 | ||||
| 07 14 00 | DIVISION 7-FLUID APPLIED WATERPROOFING | |||||||
| 0129 | FLUID APPLIED COATING SYSTEM FOR METAL ROOFS | SQ | 5 | $0.00 | ||||
| 0130 | ENERGY STAR RATED COATING SYSTEM APPLIED TO NEW BUR ROOFING WITH MODIFIED CAP SHEET | SQ | 5 | $0.00 | ||||
| 0131 | 07 56 10 | ELASTOMERIC COATING FOR ROOF REPAIRS | SQ | 5 | $0.00 | |||
| 07 71 19 | DIVISION 7-SHEET METAL WORK, GENERAL | |||||||
| FURNISH AND INSTALL NEW GRAVEL GUARD/FASCIA (FACE DIMENSION) | ||||||||
| 0132 | GALVANIZED METAL, 4"- 5" | LF | 200 | $0.00 | ||||
| 0133 | GALVANIZED METAL, 6" - 7" | LF | 100 | $0.00 | ||||
| 0134 | ALUMINUM, 4" - 5" | LF | 200 | $0.00 | ||||
| 0135 | ALUMINUM, 6" - 7" | LF | 100 | $0.00 | ||||
| 0136 | 2-PIECE GALVANIZED METAL, 7" - 10" | LF | 50 | $0.00 | ||||
| 0137 | 2-PIECE GALVANIZED METAL, 10" - 12" | LF | 50 | $0.00 | ||||
| 0138 | 2-PIECE ALUMINUM, 7" - 10" | LF | 50 | $0.00 | ||||
| 0139 | 2-PIECE ALUMINUM, 10" - 12" | LF | 50 | $0.00 | ||||
| FURNISH AND INSTALL: | ||||||||
| 0140 | GALVANIZED METAL DRIP EDGE | LF | 250 | $0.00 | ||||
| 0141 | GALVANIZED METAL COUNTERFLASHING | SF | 150 | $0.00 | ||||
| 0142 | 07 65 10 | GALVANIZED METAL VALLEY FLASHING | SF | 150 | $0.00 | |||
| 0143 | GALVANIZED METAL STEP FLASHING | SF | 100 | $0.00 | ||||
| 0144 | GALVANIZED METAL BASE FLASHING | SF | 100 | $0.00 | ||||
| 0145 | GALVANIZED METAL FLASHING- FLAT SHEET | SF | 100 | $0.00 | ||||
| 0146 | GALVANIZED METAL CAP FLASHING | SF | 100 | $0.00 | ||||
| 0147 | 07 71 43 | ALUMINUM DRIP EDGE | LF | 250 | $0.00 | |||
| 0148 | ALUMINUM COUNTERFLASHING | SF | 150 | $0.00 | ||||
| 0149 | ALUMINUM VALLEY FLASHING | SF | 200 | $0.00 | ||||
| 0150 | ALUMINUM STEP FLASHING | SF | 100 | $0.00 | ||||
| 0151 | ALUMINUM BASE FLASHING | SF | 100 | $0.00 | ||||
| 0152 | ALUMINUM FLASHING - FLAT SHEET | SF | 100 | $0.00 | ||||
| 0153 | 04 72 10 | ALUMINUM CAP FLASHING | SF | 100 | $0.00 | |||
| 0154 | METAL RIDGE VENT | LF | 100 | $0.00 | ||||
| REMOVE EXISTING EXPANSION JOINT AND INSTALL NEW EXPANSION JOINT: | ||||||||
| 0155 | 07 71 29 | ELASTOMERIC TYPE (NEOPRENE BELLOWS) | LF | 50 | $0.00 | |||
| 0156 | 2500 | ALUMINUM CAPPED CURB | LF | 50 | $0.00 | |||
| 0157 | GALVANIZED CAPPED CURB | LF | 50 | $0.00 |