Atch_2_-_FTEV_13-1001 _DrawingsFinal.pdf
PDF 2 MB Posted
- Attached to
- Upgrade Fire Suppression, Hangar 90225
- Solicitation number
- FA4417-17-R-0001
About this file
Attachment 2 Drawings
View the file
Other files
Show all 25
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
D P
R O
J E C
T
U p g r a d e
H a n g a r
F i r e
S u p p r e s s i o n
B l d g
D
W G
M e c h
T d w g
A
M
D
W G
T o
P
F p c
P
R O
J E C
T
U p g r a d e
H a n g a r
F i r e
S u p p r e s s i o n
B l d g
D
W G
M e c h
F P d w g
A
M
D
F p
P
R O
J E C
T
U p g r a d e
H a n g a r
F i r e
S u p p r e s s i o n
B l d g
D
W G
M e c h
M d w g
A
M
D
F p
P
R O
J E C
T
U p g r a d e
H a n g a r
F i r e
S u p p r e s s i o n
B l d g
D
W G
M e c h
M d w g
A
M
D
F p
P
R O
J E C
T
U p g r a d e
H a n g a r
F i r e
S u p p r e s s i o n
B l d g
D
W G
M e c h
M d w g
A
M
D
F p
FIRE ALARM SYSTEM - NEW HVAC SHUTDOWN RELAY.
MASS NOTIFICATION SYSTEM - EXISTING SIGCOM CONTROL PANEL - TO REMAIN.
LOC
ELECTRICAL LEGEND - NEW WORK:
1. THE ENTIRE INSTALLATION SHALL BE IN ACCORDANCE WITH THE LATEST ACCEPTED EDITIONS OF NFPA 70, NFPA 72, NFPA 101, UFC 3-600-01, UFC 4-010-01 AND UFC 4-021-01.
2. ALL WORK AND MATERIALS USED IN THIS PROJECT SHALL BE NEW, UNDERWRITERS LABORATORIES (UL) LISTED AND LABELED, AND SHALL BE
FURNISHED AND INSTALLED BY THE CONTRACTOR UNLESS NOTED OTHERWISE.
3. CONDUIT ROUTINGS AND DEVICE/EQUIPMENT LOCATIONS SHOWN ARE DIAGRAMMATIC ONLY, CONTRACTOR SHALL FIELD ROUTE AND LOCATE AS REQUIRED. CONDUIT ROUTINGS SHALL BE PARALLEL OR PERPENDICULAR TO BUILDING LINES.
4. THE CONDUIT SYSTEMS UTILIZED SHALL BE AS FOLLOWS:
A) BELOW GRADE - PVC SCHEDULE 40.
B) TRANSITIONS FROM BELOW GRADE (WHICH SHALL INCLUDE A "RSC" FACTORY 90 DEGREE ELBOW) TO ABOVE GRADE AND/OR THRU
SLAB - RIGID GALVANIZED STEEL (RGS).
C) INTERIOR OF BUILDING CONDUITS LESS THAN 2" IN DIAMETER (ID) - ELECTRIC METALLIC TUBING (EMT) UNLESS NOTED OTHERWISE.
D) INTERIOR OF BUILDING CONDUITS 2" IN DIAMETER (ID) OR GREATER - RIGID STEEL CONDUIT (RSC) UNLESS NOTED OTHERWISE.
E) EXTERIOR OF BUILDING EXPOSED ABOVE FINISHED GRADE - RIGID STEEL CONDUIT (RSC) UNLESS NOTED OTHERWISE.
F) FINAL 36" OF CONDUIT CONNECTED TO MOTORS AND DRY TYPE TRANSFORMERS - LIQUIDTIGHT FLEXIBLE METAL CONDUIT (LFMC).
5. ALL NEW CONDUITS RUN UNDERGROUND SHALL HAVE A MINIMUM BURIAL DEPTH OF 36" UNLESS NOTED OTHERWISE.
6. NEW CONDUITS LEAVING OR ENTERING BUILDING SHALL BE SEALED PER N.E.C. TO PREVENT ENTRANCE OF MOISTURE.
7. ALL NEW FIRE ALARM AND MASS NOTIFICATION SYSTEM CONDUITS SHALL BE "RED" IN COLOR.
8. COORDINATE LOCATIONS OF ALL NEW ELECTRICAL EQUIPMENT, DEVICES, OUTLETS, ETC., WITH EXISTING LIGHTING FIXTURES, MECHANICAL
DIFFUSERS, PUBLIC ADDRESS SPEAKERS, ETC. PRIOR TO ROUGH-IN WORK.
9. WHERE CONFLICTS OCCUR ON ELECTRICAL DRAWINGS BETWEEN DRAWINGS, SPECIFICATIONS AND CODES, THE MOST STRINGENT
REQUIREMENT THAT APPLIES SHALL BE ADHERED TO.
10. ELECTRICAL CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO BEGINNING ANY WORK AND SHALL IMMEDIATELY NOTIFY THE GOVERNMENT INSPECTOR OF ANY DISCREPANCIES. FAILURE TO DO SO INDICATES THAT THE CONTRACTOR ACCEPTS THE
CONDITIONS AS THEY EXIST AND SHALL PERFORM THE WORK AS SHOWN AND SPECIFIED.
11. WHERE ITEMS ON DEMOLITION DRAWINGS ARE SHOWN TO BE REMOVED, REMOVAL SHALL INCLUDE WIRING AND CONDUIT BACK TO CONTROL PANEL FROM WHICH WIRING AND CONDUIT ORIGINATED. CONDUITS WHICH ARE CONCEALED BELOW FLOORS OR IN WALLS MAY BE
ABANDONED IN PLACE.
12. ALL REMOVED FIRE ALARM EQUIPMENT IS TO BE TURNED OVER TO THE GOVERNMENT.
13. ALL NEW OUTLET BOXES FOR NEW FIRE ALARM AND MASS NOTIFICATION DEVICES SHALL BE 4" SQUARE X 1 1/2" DEEP UNLESS NOTED
OTHERWISE.
14. ALL NEW FIRE ALARM AND MASS NOTIFICATION SYSTEM CIRCUITS SHALL BE TERMINATED ON TERMINAL STRIPS. WIRE NUTS ARE PROHIBITED.
ALL SIGNALING LINE CIRCUITS (SLC) AND NOTIFICATION APPLIANCE CIRCUITS (NAC) ENTERING THE BUILDING AND AT THE FIRE ALARM PANEL
SHALL BE PROVIDED WITH SUITABLE SURGE SUPPRESSORS (SEE SPECIFICATIONS)
15. THE CONTRACTOR SHALL NOTIFY THE CONTRACTING OFFICER 30 DAYS BEFORE THE PRELIMINARY AND ACCEPTANCE FIRE ALARM TESTS ARE TO BE CONDUCTED. THE TESTS SHALL BE IN ACCORDANCE WITH THE APPROVED TESTS PROCEDURES IN THE PRESENCE OF THE CONTRACTING OFFICER. THE CONTRACTOR SHALL FURNISH ALL INSTRUMENTS AND PERSONNEL REQUIRED FOR THE TESTS.
16. ANY WORK THAT WILL DISABLE THE FIRE ALARMS WILL HAVE TO BE APPROVED BY THE FACILITY DIRECTOR. IF APPROVED, THE FACILITY DIRECTOR WILL COORDINATE, WITH ASSISTANCE OF FIRE PREVENTION, A FIRE WATCH AND PUT CORRECTIVE MEASURES IN PLACE. THE CONTRACTOR CAN TEAM UP WITH THE DIRECTOR SO THEY COMMUNICATE WITH FRONT DESK AS ADDITIONAL FIRE WATCH.
GENERAL FIRE ALARM NOTES:
FIRE ALARM SYSTEM - NEW CIRCUITRY IN CONDUIT - 3/4"C. MINIMUM.F
FIRE ALARM SYSTEM - EXISTING FLOW SWITCH CONNECTION - TO REMAIN.
FIRE ALARM SYSTEM - EXISTING TAMPER SWITCH CONNECTION - TO REMAIN.
FIRE ALARM SYSTEM - EXISTING PRESSURE SWITCH CONNECTION - TO REMAIN.
FIRE ALARM SYSTEM - EXISTING NOTIFIER FIRE ALARM CONTROL PANEL - TO REMAIN.
FACP
ELECTRICAL LEGEND - DEMOLITION:
FIRE ALARM SYSTEM - SPRINKLER SYSTEM FLOW SWITCH CONNECTION - TO REMAIN.
FIRE ALARM SYSTEM - SPRINKLER SYSTEM FLOW SWITCH CONNECTION - TEMPORARILY DISCONNECT EXISTING CONNECTION - SEE NEW WORK.
TR
FOAM SYSTEM - CONTROL PANEL.
FIRE ALARM SYSTEM - FLOW SWITCH CONNECTION - RECONNECT NEW FLOW SWITCH TO EXISTING MONITORING MODULE.
FIRE ALARM SYSTEM - TAMPER SWITCH CONNECTION - RECONNECT NEW TAMPER SWITCH TO EXISTING MONITORING MODULE.
FIRE ALARM SYSTEM - PRESSURE SWITCH CONNECTION - RECONNECT NEW PRESSURE SWITCH TO EXISTING MONITORING MODULE.
FCP
FIRE ALARM SYSTEM - EXISTING TRANSCEIVER - TO REMAIN.
MNSP
MASS NOTIFICATION SYSTEM - EXISTING LOCAL OPERATORS CONSOLE UNIT W/ HVAC EMERGENCY SHUTOFF - TO REMAIN.
FIRE ALARM SYSTEM - SPRINKLER SYSTEM TAMPER SWITCH CONNECTION - TO REMAIN.
FIRE ALARM SYSTEM - SPRINKLER SYSTEM TAMPER SWITCH CONNECTION - TEMPORARILY DISCONNECT EXISTING CONNECTION - SEE NEW WORK.
FIRE ALARM SYSTEM - SPRINKLER SYSTEM PRESSURE SWITCH CONNECTION - TO REMAIN.
FIRE ALARM SYSTEM - SPRINKLER SYSTEM PRESSURE SWITCH CONNECTION -TEMPORARILY DISCONNECT EXISTING CONNECTION - SEE NEW WORK.
M
FIRE ALARM SYSTEM - EXISTING MONITOR MODULE - REMOVE.
ELECTRICAL PLAN - AFFF ROOM -
DEMOLITION
FS
FS
TS
TS
PS
PS
PS
TS
FS
R
FS
TS
PS
SCALE: 1/4" = 1'-0"
ELECTRICAL PLAN - AFFF ROOM -
NEW WORK
SCALE: 1/4" = 1'-0"
MNSP
FACP
TR
FCP
TS FS
TS FS
TS FS
TS PS
TS PS
MNSP
FACP
TR
FCP
TS FS
TS FS
TS FS
TS FS
EXISTING WET PIPE
SYSTEM # 1
EXISTING FOAM
RISER # 3
EXISTING FOAM
RISER # 2
EXISTING UNDERWING
FOAM RISER
EXISTING WET PIPE
SYSTEM # 2
1/4" = 1'-0" 4' 0' 4' 12'8' 16'
GRAPHIC SCALE
TS PS TS TS
TSEXISTING FOAM
BLADDER PIPING
EXISTING WET PIPE
SYSTEM # 1
EXISTING FOAM
RISER # 3
EXISTING FOAM
RISER # 2
EXISTING UNDERWING
FOAM RISER
EXISTING WET PIPE
SYSTEM # 2
TS
TS
TS
TS
TS TS
M
M M
R R
R R
M
FIRE ALARM SYSTEM - SPRINKLER SYSTEM TAMPER SWITCH CONNECTION - REMOVE EXISTING CONNECTION.TS
FOAM SYSTEM - EXISTING CONTROL PANEL - TO BE REMOVED BY THE FIRE PROTECTION CONTRACTOR.
FCP
JX
X
X
NEW EXPLOSION PROOF CONDUIT SEALING FITTING.
NEW EXPLOSION PROOF FLEXIBLE CONDUIT & WIRING CONNECTION.
NEW EXPLOSION PROOF JUNCTION BOX.
FIRE ALARM SYSTEM - NEW FOAM SYSTEM TEMPERATURE SENSOR CONNECTION.
MANUAL FIRE ALARM PULL STATION
FIRE ALARM SMOKE DETECTOR
DUCT SMOKE DETECTOR - SUPERVISORY
TR
AN
SM
IT
C O
M M
O N
F
IR
E
AL
AR
M
S
IG
N
AL
VI
A
TR
AN
SC
EI
VE
R
T O
F .D
X INDICATES EXISTING SETTINGS OF FIRE ALARM/MASS NOTIFICATION SYSTEM
INDICATES NEW SETTINGS REQUIRED UNDER THIS CONTRACT
FIRE ALARM / MASS
NOTIFICATION SYSTEM
FUNCTIONAL MATRIX
TR
AN
SM
IT
IN
D
IV
ID
U
AL
W
AT
ER
FL
O W
A
LA
R M
PE
R
R
IS
ER
V
IA
T
R
AN
SC
EI
VE
R
T O
F .D
TR
AN
SM
IT
S
PR
IN
KL
ER
S U
PE
R
VI
SO
R Y
VI
A
TR
AN
SC
EI
VE
R
T O
F .D
TR
AN
SM
IT
D
U C
T D
ET
EC
TO
R
S U
PE
R
VI
SO
R Y
VI
A
TR
AN
SC
EI
VE
R
T O
F .D
TR
AN
SM
IT
S
U
PE
R
VI
SO
R
Y M
N S
O
VE
R R
ID
E
O F
FI
R
E
AL
AR
M
V
IA
T R
AN
SC
EI
VE
R T
O F
.D
TR
AN
SM
IT
E M
ER
G
EN
C
Y
SH
U
TD
O W
N O
F H
VA
C
V
IA
T R
AN
SC
EI
VE
R T
O F
.D
TR
AN
SM
IT
M N
S
PA
N
EL
C O
M M
O N
T R
O U
BL
E
VI
A
TR
AN
SC
EI
VE
R
T O
F .D
TR
AN
SM
IT
F
A
PA
N
EL
C O
M M
O N
T R
O U
BL
E
VI
A
TR
AN
SC
EI
VE
R
T O
F .D
IN
D
IC
AT
E
AL
AR
M C
O N
D
IT
IO
N
O N
F A
PA
N
EL
D
IS
PL
AY
A N
N U
N C
IA
TO
R
IN
D
IC
AT
E
SU
PE
R
VI
SO
R
Y C
O N
D
IT
IO
N
O N
F A
PA
N
EL
D
IS
PL
AY
A N
N U
N C
IA
TO
R
IN
D
IC
AT
E
TR
O
U
BL
E C
O N
D
IT
IO
N
O N
F A
PA
N
EL
D
IS
PL
AY
A N
N U
N C
IA
TO
R
R
EC
O R
D E
VE
N
T
IN
F
AC
P H
IS
TO
R Y
BU
FF
ER
AC
TI
VA
TE
C
LE
AR
F
IR
E
ST
R
O
BE
S
PL
AY
F
IR
E
AL
AR
M
M
ES
SA
G
E
PL
AY
M N
S M
ES
SA
G E
AS
SO
C
IA
TE
D
W
IT
H
BU
TT
O
N
AC
TI
VA
TE
A M
BE
R
A
LE
R T
ST
R
O
BE
S
O
VE
R R
ID
E
FA
M
ES
SA
G E
AN
D
C
LE
AR
ST
R O
BE
S
SH
U
TD
O
W N
A
SS
O C
IA
TE
D H
VA
C
U N
IT
EM
ER
G
EN
C Y
SH
U
TD
O
W N
O F
AL
L
H
VA
C
EQ
U
IP
M
EN
T
SPRINKLER FLOW SWITCH - RISER # 2
SPRINKLER FLOW SWITCH - RISER # 1
TEMPERATURE SENSORS IN HANGAR
FOAM SYSTEM CONTROL PANEL
FACP AC POWER FAILURE
FACP SYSTEM LOW BATTERY
FACP OPEN CIRCUIT
FACP GROUND FAULT
REMOTE POWER SUPPLY TROUBLE
MNS LOC MICROPHONE ACTIVE - PRIORITY 3
MNS DIGITAL MESSAGE 1-3 ACTIVE - PRIORITY 4-6
MNS DIGITAL MESSAGE 5-8 ACTIVE
MNS LOC HVAC SHUTDOWN SWITCH ACTIVE
MNS AC POWER FAILURE
MNS SYSTEM LOW BATTERY
MNS NOTIFICATION APPLIANCE CIRCUIT SHORT
MNS ACU PTT MICROPHONE ACTIVE - PRIORITY 1
MNS LIVE VOICE MESSAGE ACTIVE - PRIORITY 2
SPRINKLER CONTROL VALVE
MNS OPEN CIRCUIT
MNS GROUND FAULT
X X X X
X X
X X
X X X X
X X
X X X X X X X X X
X X X
X
X X X X
X
X
X X X X X
X X X X X
X X X X X
X X X
X X X X X
X X
X X X
X X X X X X X X
TR
AN
SM
IT
T
EM
PE
R
AT
U
R E
SE
N
SO
R
SU
PE
R
VI
SO
R
Y
VI
A
TR
AN
SC
EI
VE
R T
O F
.D
}DEVICES SHALL BE CONNECTED
TO THE FOAM SYSTEM CONTROL
PANEL. SEE FIRE PROTECTION
DRAWINGS.
EXISTING AND NEW DEVICES
SHALL BE CONNECTED TO THE
FIRE ALARM CONTROL PANEL.
TSNEW TAMPER SWITCH
AT VALVE.
SEE "FIRE ALARM
TRANSCEIVER NOTE,"
SHEET E-2.
TS
TS
M
M
FIRE ALARM SYSTEM - NEW MONITOR MODULE.M
FIRE ALARM SYSTEM - NEW TAMPER SWITCH CONNECTION.TS
NEW EXIT LIGHT FIXTURE - SEE DETAILS, SHEET E-3.
90225
30 APRIL 2015
OF 17
FTEV 13-1001
U
PG
R
AD
E H
AN
G
AR
F
IR
E
SU
PP
R
ES
SI
O
N S
YS
TE
M
BL
D G
. 9
JRH
EWW/JRH
EL
EC
TR
IC
AL
L
EG
EN
D S
E-1
ELECTRICAL PLAN - FIRE ALARM SYSTEM - EAST SIDE
NORTH
SCALE: 1/8" = 1'-0"
AIRCRAFT
PAINT BAY
PAINT
STORAGE
COMP.
ROOM 125
AFFF
ELEC.
HVAC
MECH. ROOM
BREAK/
TRAINING
COMM.
1/8" = 1'-0" 8' 0' 8' 24'16' 32'
GRAPHIC SCALE
NOT TO SCALE
KEY PLAN
NORTH
MNSP
FACP
TR
SEE ELECTRICAL PLANS FOR DEMOLITION AND
NEW WORK ON SHEET E-1 FOR WORK IN THIS ROOM.
FCP
LO
C
ENTIRE HANGAR BAY AREA IS A CLASSIFIED ENVIRONMENT. ALL ELECTRICAL INSTALLATION
WITHIN THE HANGAR BAY SHALL BE LISTED FOR CLASS 1, DIVISION 1 LOCATIONS.
J JF
F
X
X
X
X
X
R
R
F
F
REMOVE EXISTING EXIT LIGHT &
INSTALL NEW EXIT LIGHT IN EXISTING
LOCATION. RECONNECT EXISTING
CONDUIT & WIRING. SEE DETAIL,
SHEET E-3.
CONNECT NEW HVAC SHUT DOWN RELAYS TO EXISTING DDC
CONTROLLERS FOR EXHAUST FANS 1 THRU 8, 16, 17 & 18.
INSTALL INLINE SURGE PROTECTIVE DEVICE (EDCO #
HSP-121A OR EQUAL) ON EXISTING 120 VOLT CIRCUIT &
RECONNECT TO NEW FOAM SYSTEM CONTROL PANEL.
RECONNECT EXISTING FIRE ALARM CIRCUIT TO NEW
FOAM SYSTEM CONTROL PANEL. PROVIDE NEW WIRING
IN EXISTING CONDUIT FROM FOAM SYSTEM CONTROL
PANEL TO EXISTING MONITOR MODULES.
NOTE:
INSTALL EXPLOSION PROOF CONDUIT SEALING FITTING
WHERE CONDUITS LEAVES CLASSIFIED ENVIRONMENT.
EXISTING LOC W/ EMERGENCY SHUTDOWN
SWITCH FOR HVAC EQUIPMENT.
XXX
REMOVE EXISTING EXIT LIGHT &
INSTALL NEW EXIT LIGHT IN EXISTING
LOCATION. RECONNECT EXISTING
CONDUIT & WIRING. SEE DETAIL,
SHEET E-3.
EXTEND CONDUIT & WIRING TO NEAREST FIRE ALARM INITIATING DEVICE.
FIRE ALARM TRANSCEIVER NOTE;
THE FIRE ALARM CONTRACTOR SHALL INSTALL (1) 4 ZONE EXPANSION CARD IN THE EXISTING MONACO BTX-M FIRE ALARM TRANSCEIVER. THE NEW TEMPERATURE SENSORS IN THE HANGAR SHALL TRANSMIT A SUPERVISORY CONDITION TO THE CENTRAL RECEIVING STATION OVER 1 ZONE IN THE EXPANSION CARD. THE FOAM SYSTEM CONTROL PANEL SHALL BE CONNECTED TO THE EXISTING FIRE ALARM
TRANSCEIVER TO TRANSMIT ALARM/SUPERVISORY CONDITIONS OVER THE OTHER 3 ZONES.
HVAC SHUT DOWN NOTE;
ALL NEW AND EXISTING HVAC SHUT DOWN RELAYS SHALL BE PROGRAMMED TO SHUT DOWN THE
ASSOCIATED DDC CONTROL EQUIPMENT WHEN THE HVAC SHUT DOWN SWITCH IN THE MASS
NOTIFICATION SYSTEM LOCAL OPERATOR CONSOLE IS ACTIVATED.
REMOVE EXISTING EXIT LIGHT &
INSTALL NEW EXIT LIGHT IN EXISTING
LOCATION. RECONNECT EXISTING
CONDUIT & WIRING. SEE DETAIL,
SHEET E-3.
REMOVE EXISTING EXIT LIGHT &
INSTALL NEW EXIT LIGHT IN EXISTING
LOCATION. RECONNECT EXISTING
CONDUIT & WIRING. SEE DETAIL,
SHEET E-3.
EXTEND TO FACP VIA MONITOR MODULES -
INSTALL MONITOR MODULES IN AFFF ROOM.
90225
30 APRIL 2015
R
AD
E H
AN
G
AR
F
IR
E
SU
PP
R
ES
SI
O
N S
YS
TE
M
BL
D G
. 9
JRH
EWW/JRH
EL
EC
TR
IC
AL
P
LA
N
FI
R E
AL
AR
M S
YS
TE
M
EA
ST
S
ID
E
E-2
ELECTRICAL PLAN - FIRE ALARM SYSTEM - WEST SIDE
NORTH
SCALE: 1/8" = 1'-0"
1/8" = 1'-0" 8' 0' 8' 24'16' 32'
GRAPHIC SCALE
NOT TO SCALE
KEY PLAN
NORTH
GMAU-1
PAINT BOOTH EXHAUST FANS
MAKE-UP
AIR UNIT
R F
3 WATT LED LAMP. 120/277 VOLT DUAL VOLTAGE INPUT.
WALL MOUNTING BRACKET.
DETAIL - EXIT FIXTURE
N.T.S.
EXIT SIGN W/ RED LETTERS ON ACRYLIC EDGE LIT PANEL.
COPPER FREE ALUMINUM HOUSING. FIXTURE SHALL BE LISTED FOR CLASS 1, DIVISION 1,
GROUPS C & D. FURNISH WITH NICKEL CADMIUM BATTERY AND CHARGER FOR 90
MINUTES OF BACKUP POWER.
5 TEST SWITCH AND READY LIGHT.
6 RECONNECT EXISTING CONDUIT & WIRING. CONDUIT ORIENTATION VARIES FROM THIS DETAIL.
R F
CONNECT NEW HVAC SHUT DOWN RELAY TO NEW DDC
CONTROLLER FOR PAINT BOOTH EXHAUST FANS & MAKE
UP AIR UNIT.
R
F
CONNECT NEW HVAC SHUT DOWN RELAYS TO EXISTING
DDC CONTROLLERS FOR EF-9 & GMAU-1.
EXTEND CONDUIT & WIRING TO NEAREST FIRE ALARM INITIATING DEVICE.
EF-9
EXTEND CONDUIT & WIRING TO NEAREST FIRE ALARM INITIATING DEVICE.
90225
30 APRIL 2015
R
AD
E H
AN
G
AR
F
IR
E
SU
PP
R
ES
SI
O
N S
YS
TE
M
BL
D G
. 9
JRH
EWW/JRH
EL
EC
TR
IC
AL
P
LA
N
FI
R E
AL
AR
M S
YS
TE
M
W
ES
T
SI
D E
E-3
| 14125T1-T001 |
| 14125FP1-- |
| 14125FP2-Layout1 |
| 14125FP3-Layout1 |
| 14125FP4-Layout1 |
| 14125FP5-Layout1 |
| 14125FP6-Layout1 |
| 14125FP7-Layout1 |
| 14125FP8-Layout1 |
| 14125FP9-Layout1 |
| 14125FP10-Layout1 |
| 14125M1-Layout1 |
| 14125M2-Layout1 |
| 14125M3-Layout1 |
| FTEV 13-1001 E1 |
| FTEV 13-1001 E2 |
| FTEV 13-1001 E3 |
File details come from the government source that posted it. Updated .