Amend_6_Addendum_4.doc

DOC document 28 KB Posted

Attached to
Upgrade Fire Suppression, Hangar 90225
Solicitation number
FA4417-17-R-0001
Issued by

About this file

This is addendum #4, added verbiage to addendum #3.

View the file

Other files

File Type Posted
Amend_6_FA4417-17-R-0001-0006.docx DOCX document
Amend_5_FA4417-17-R-0001-0005.docx DOCX document
Amend_5_ADDENDUM_3.doc DOC document
Additional_Question_and_Answer.docx DOCX document
RFI's_FA4417-17-R-0001_FTEV_13-1001-Answered_3.docx DOCX document
sprinkler_pipe_sizes.pdf PDF
RFI's_FA4417-17-R-0001_FTEV_13-1001-Answered_12_Jan_17.docx DOCX document
FTEV13-1001Specifications_Rev-1-3-17.pdf PDF
FTEV_13-1001_revised_drawings_1-3-17_.pdf PDF
ADDENDUM__2.doc DOC document
Amendment_4.docx DOCX document
RFI's_FA4417-17-R-0001_FTEV_13-1001-Answered.docx DOCX document
FA4417-17-R-0001-0003_Amendment_3.pdf PDF
Site_Visit_Minutes_and_Sign_In_sheet.pdf PDF
FA4417-17-R-000102.docx DOCX document
02_FTEV13-1001Specifications_1_Dec_16.pdf PDF
Amendment_FA4417-17-R-0001-0001.docx DOCX document
FTEV_13-1001_drawings_1_Dec_16.pdf PDF
Atch_2_-_FTEV_13-1001 _DrawingsFinal.pdf PDF
Atch_4_-_PPQ _17R0001.docx DOCX document
Atch_1_-_FTEV_13-1001 SpecificationsFinal.pdf PDF
Solicitation_FA4417-17-R-0001.docx DOCX document
Atch_5_-_Financial_Worksheet _17R0001.docx DOCX document
Atch_3_-_Wage_Det _17R0001.docx DOCX document
Atch_6 _ _Add_Contract_Reqs _17R0001.docx DOCX document
Show all 25

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PROJECT # FTEV 13-1001

UPGRADE HANGAR FIRE SUPPRESSION SYSTEM

BUILDING 90225

ADDENDUM #4

24 Jan. 2017 1.

Replace the addendum #3 with the paragraph below.

“The existing overhead wet pipe system shall be re-used to the largest extent possible. The contractor shall be responsible for replacement of portions of the system as required to reduce pressure drop for the final overall hydraulic calculations. The upper level wet pipe system shall be used in the calculations. The contractor shall also include the cost of changing out the impellers in the 3 existing fire pumps in building 90705. The pumps are Patterson model number 10X8X17SSC with 250 horsepower motors. The representative for the pumps is Hydro Technologies, point of contact is Danny Dunaway 251-478-1104. The contractor shall schedule the work so that two of the pumps are operational at all times.”

END OF ADDENDUM