This Statement of Work (SOW) details the requirements for a Bunker Conex Training Facility for the 365th Training Squadron at Sheppard Air Force Base in Texas. The project involves engineering, furnishing, installing, and testing a facility consisting of four to six shipping container-based bunkers, a covered area of approximately 5,600 square feet, and extensive fitness equipment. The equipment list is comprehensive, including 8 each of ski ergs, echo bikes, and rowers, 12 TRX systems, multiple kettlebell and dumbbell sets ranging from 5 to 52 pounds, various bars and plates, plyo boxes, medballs, sleds, and additional accessories like pull-up bars and resistance bands.

The facility's objective is to modernize Air Force physical training, providing a versatile space for conducting fitness sessions. The project will be located on the Ground Instructional Training Aircraft Ramp north of Hangar 1020, with specific requirements including a rubber floor, open-faced containers, and features like air flow flaps and transparent roof sections. The 82d Civil Engineering Squadron will not provide electrical support, so the facility will not include fans, lighting, or TVs. The contractor is responsible for foundation preparation, securing containers, and ensuring minimal damage to existing structures during installation.

View the file

Other files

Show all 13

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Statement of Work (SOW) FY23 365th TRW Bunker Conex Training Facility

1.

WORK COVERED BY CONTRACT DOCUMENTS:

1. Project Description: This Statement of Work (SOW) defines the requirements for the Contractor to Engineer, Furnish, Install and Test (EFI&T) all components of the Quad Bunker Conex Training Facility.

2. Location: The work shall be located at Sheppard Air Force Base (SAFB), which is located in Wichita County, in the northern part of Wichita Falls, TX. The location of the Project on SAFB is on the Ground Instructional Training Aircraft (GITA) Ramp North of Hanger 1020 (see Attachment 1). The project is FY25 365th Bunker Conex Training Facility.

3. Objective: To fulfill the 2AF/CC PT Imitative and the 82 TRW/CC SPEAR Team’s goal of modernizing AiT PT to bring better habits, training, fitness scores, and overall lifestyle for their entire AF career; the 365th TRS requires a Four to Six Bunker Configuration Conex Training Facility as described below. This package will meet the requirement to provide another means of effectively conducting physical training sessions.

4. General Requirements: The Contractor shall provide all equipment, tools, materials, supplies, transportation, labor, supervision, management, and other incidentals necessary to meet the requirements as stated in this SOW.

5. The Minimum Required Specifications - Bunker Conex Training Facility:

a. Four to Six Bunker Configuration:

Item Description QTY

Bunker Conex 40' Open Faced Conex Customized and

Outfitted (8’x40’)

Bunker Conex (optional)

20' Open Faced Conex Customized and Outfitted (8’x20’)

Covered Area Approximately 56’x100’ = 5600 Sq Ft

Steel Structure, Frame, Siding (40’ x 100’ under roof)

Built in flaps to allow air flow/ Plastic Roll Up panels at openings Transparent roof sections for natural light Fully in-closable to prevent bird access Installation/ Erection Training equipment as defined on the plans

b. Bunker Equipment List:

Item Description QTY Fitness Machines Ski Erg Single 8 Echo Bike Single 8 Rower Single 8 Yokes Single 4 TRX Single 12 Kettlebells

22 lbs Pair 6 26 lbs Pair 6 30 lbs Pair 6 35 lbs Pair 10 39 lbs Pair 6 44 lbs Pair 8 52 lbs Pair 10

Dumbells 5 lbs Pair 4 10 lbs Pair 4 15 lbs Pair 4 20 lbs Pair 6 25 lbs Pair 8 30 lbs Pair 8 35 lbs Pair 8 40 lbs Pair 6 45 lbs Pair 6 50 lbs Pair 6 55 lbs Pair 8

Bars Hex Bars Single 8 Barbells Single 10 Barbell Bomb Single 4 Bumper Plates

5 lbs Pair 20 10 lbs Pair 40 25 lbs Pair 38 45 lbs Pair 34

Plyo Box 12 inch height Single 8 18 inch height Single 8 24 inch height Single 8

Item Description QTY

Rope Climb with Ceiling Attachment 8 Medballs

6 lbs Single 4 8 lbs Single 4

10 lbs Single 8 12 lbs Single 4 14 lbs Single 8 16 lbs Single 4 18 lbs Single 4 20 lbs Single 8

Sand Disks 20 lbs Single 4 30 lbs Single 12 40 lbs Single 4

Deadball 60 lbs Single 11 80 lbs Single 11

100 lbs Single 10 Sleds

Spud Inc Sled + Harness

Single 12

Tank Single 4 Duffles

35-100 Single 16 Attachments

Dip Attachment Single 8

Pull-up Bars Length of the Bunker (Approximately

39')

Miscellaneous Versa Loops 6 Pack 80

Versa Loops - Extra Light Band

Single 80

Versa Loops - Light Band

Single 80

Versa Loops - Medium Band

Single 80

Versa Loops - Heavy Band

Single 80

Versa Loops - Extra Heavy Band

Single 80

Versa Loops - Ultra Heavy Band

Single 80

Squat Rack 4 Kettlebell Rack 1

Dumbell Rack 1 Barbell Rack 1

Specific Requirements: The Contractor shall provide all foundation preparation and work to secure the containers and covering to the foundation. The 82 CES will not provide electrical support for this equipment, therefore fans, lighting, TVs, etc. are not required

Existing Work: In addition to "FAR 52.236-9, Protection of Existing Vegetation, Structures, Equipment, Utilities, and Improvements":

Remove or alter existing work in such a manner as to prevent injury or damage to any portions of the existing work, which remain.

Repair or replace portions of existing work, which have been altered during installation operations to match existing or adjoining work, as approved by the CO. At the completion of operations, existing work shall be in a condition equal to that which existed before new work started as approved by the CO.

The contractor shall provide documentation in the form of drawing markups and/or photographs of existing damage within the work area prior to beginning installation.

Any damage that is found that was not documented as existing shall become the responsibility of the contractor to repair.

Attachment 1 Site Map