This document is an Addendum to a federal contract for repairing elevators at Keesler Air Force Base in Mississippi. The project involves elevator repairs at multiple NPS (Navy Personnel Support) dormitories, including Foster Manor, Winters Manor, Smith Manor, and Davis Manor. Key modifications include: limiting contractor access to three facilities at a time, adding two additional facilities (Foster Manor and Winters Manor) for sump work only, and exempting certain facilities (Smith Manor and Davis Manor) from elevator flooring removal and replacement. The contract specifies that upon 100% completion and government acceptance of work in one facility, another facility may be released to the contractor. The addendum also stipulates that the existing car entrance sill is to remain, altering previous specification requirements.
View the file
Other files for this federal contract opportunity
Show all 15
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Attachment 8
FA301025R0024
ADDENDUM 1 Date: August 26, 2025
CONTRACT NUMBER:
PROJECT NAME: Repair NPS Dorm Elevators
LOCATION: Triangle Area - Keesler AFB, Mississippi
PROJECT NUMBER: MAHG23-1016
WORK ORDER #: NA
This Addendum is hereby part of the Contract Documents. The following conditions take precedence over conflict conditions in the Specifications, on the Drawings, and in any other Contract Document. When a change is called for on a Drawing, this change shall carry through all applicable drawings, including all related architectural, civil, structural, mechanical, plumbing and electrical drawings. The Contract Documents are hereby amended in the following particulars:
I. Relating to the Statement of Work:
A. Reference 3.1.1 NPS Dorms
1. Add B6965 Foster Manor to complete sump work only. No interior nor electrical upgrades required for this elevator.
2. Add B7404 Winters Manor to complete sump work only. No interior nor electrical upgrades required for this elevator.
B. Reference 3.2 Description of work, 3.2.2:
1. Omit Sentence: The contractor shall phase work and complete all work within a single structure before being allowed to begin work in a subsequent structure.
2. Insert Sentence: The contractor shall have access to only three facilities at any given time. Upon 100% completion within one facility and upon acceptance by the government, another facility may be released to the contractor.
C. Reference SOW 3.2.5.2.1 Demolition and SOW 3.2.5.3.21 New Construction
1. 3.2.5.2.1: “Remove the elevator flooring” does not apply to B7315 Smith Manor and
B6955 Davis Manor.
2. 3.2.5.3.21: “Install new VCT flooring in the elevator cab” does not apply to B7315
Smith Manor and B6955 Davis Manor.
II. Relating to the Specifications:
A. Reference Section 14 24 23 Hydraulic Passenger Elevators, 2.8 Passenger Elevator Guides, Platform, and Enclosure, 2.8.5 Car Entrance Sill: Omit sentence in its entirety. The existing car entrance sill is to remain.
III. As-Built Drawings
A. Attached for reference only.
END OF ADDENDUM 1