Attachment 4 - MAHG231016 Repair NPS Dorms Elevators__DWG.pdf
PDF 456 KB Posted
- Attached to
- Repair NPS Dorms Elevators Federal contract opportunity
- Solicitation number
- FA301025R0024
About this file
These are design documents for a sump pump installation project at Keesler Air Force Base in Biloxi, Mississippi. The project, identified as MAHG231016, involves installing new sump pumps in elevator pits for buildings B6950, B7315, B7320, and B7420. The 100% design submittal includes mechanical and electrical plans detailing the installation process, which involves sawcutting existing concrete slabs, installing a new sump pit with gravel drainage, adding a submersible pump, and connecting to existing san sewer lines. The project documentation includes detailed technical specifications, general plumbing and electrical notes, and compliance requirements with various codes such as UFC, NFPA, and NEC standards.
The solicitation (FA301025R0024) is a Service-Disabled Veteran-Owned Small Business set-aside with a project value between $1,000,000 and $5,000,000. A mandatory site visit is scheduled for 11 August 2025 at 2:00 PM CDT, with specific entry requirements including valid identification and vehicle documentation. The project is being issued by the Department of the Air Force Air Education and Training Command, with a notice that funds are not currently available and the government reserves the right to cancel the solicitation.
View the file
Other files for this federal contract opportunity
Show all 15
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
R
ES
ER
VA
TI
O
N B
O U
N D
AR
Y
AV
EN
U E
STEVENS ST.
R O
D
EN
BE
R
G
STREET
IB
ER
VI
LL
E
D R
PERRY DRIVE
CARROL DRIVE
PRINGLE
PRINGLE CIRCLE
ST
M
AR
Y B
LV
D
GORDON AVENUE
LEWIS AVENUE
ST. MARTHA AVENUE
ANITA
ST ANN ST
WILTSHIRE BLVD.
SUNSET BLVD.
VINE ST.
R O
D
EO
D R
LOUISVILLE & NASHVILLE R.R.
PLOESTI DR
Z ST
PARADE LN
E ST
D ST
HANGAR RD
SEC
O
N D
ST
FALCON ST
PHANTOM ST
G
ALAXY ST
PASS RD
HANGAR RD
M ST
HANGAR RD
PHANTOM ST
MEADOWS D
R
Z
ST
H S T
HERCULES ST
E ST
HER
CULE
S
ST
PL
O
ES
TI
D R
FIR
ST ST
PLO
ESTI D
R
GEN CHAPPIE JAMES AV
69507315
7333 6956
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
IS
SU
E D
AT
E:
SI
ZE
M
AR
K
D
ES
C R
IP
TI
O N
D
AT
E
SHEET ID
ISSUE DATE:
KEESLER AIR FORCE BASE BILOXI, MS
PROJECT NUMBER:
ELEVATOR SUMP PUMP
MAHG231016
April 25
ST
C
IV
IL
E
N G
IN
EE
R S
Q U
AR
D
R O
N
L
ST
R
EE
T
B4
BI
LO
XI
, M S
M ay
AN
SI
D
KE
ES
LE
R
A
IR
F O
R C
E
BA
SE
B
IL
O
XI
, M
IS
SI
SS
IP
PI
SU
M P
PU
M
P
PL
AN
B
, B
, B
, B
PR
O
JE
C T
N O
M
AH
G
0%
D
ES
IG
N
S U
BM
IT
TA
L
G . R
EE
D
M . T
AN
N
ER
G . R
EE
D
C O
VE
R
S H
EE
TS
G-001
SHEET LIST TABLE
SHEET NUMBER SHEET TITLE
GENERAL
G-001 COVER SHEETS
MECHANICAL
P-101 SUMP PUMP PLAN
ELECTRICAL
E-001 GENERAL NOTES
1625958128A Text Box Attachment 4
FA301025R0024
1625958128A Text Box
1625958128A Text Box
INSTALL NEW SUMP
PIT IN EXISTING
ELEVATOR PIT P-1
TIE 2" SAN.PIIPE
INTO EXISTING
8" SAN. PIPE
EXISTING 8" SAN. SEWER
FINISH FLOOR
EXISTING ELEVATOR
SHAFT WALL
EXISTING ELEVATOR
PIT WALL
EXISTING ELEVATOR
PIT SLAB
1'-6"
CHECK VALVE
FILL IN GRAVEL FOR
SUMP WATER DRAINAGE
2" PVC PIPE
SAW CUT EXISTING
SLAB FOR SUMP PIT
1' -0
" B .T
.F
6"EXISTING GRAVEL
REPAIR CONCRETE SLAB
TO THE SUMP PIT
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
IS
SU
E D
AT
E:
SI
ZE
M
AR
K
D
ES
C R
IP
TI
O N
D
AT
E
SHEET ID
ST
C
IV
IL
E
N G
IN
EE
R S
Q U
AR
D
R O
N
L
ST
R
EE
T
B4
BI
LO
XI
, M S
M ay
AN
SI
D
KE
ES
LE
R
A
IR
F O
R C
E
BA
SE
B
IL
O
XI
, M
IS
SI
SS
IP
PI
SU
M P
PU
M
P
PL
AN
B
, B
, B
, B
PR
O
JE
C T
N O
M
AH
G
0%
D
ES
IG
N
S U
BM
IT
TA
L
GENERAL PLUMBING NOTES
1. PROVIDE ACCESS DOORS FOR VALVES LOCATED IN
AREAS UNACCESSIBLE WITH OUT DEMOLISHING
BUILDING SURFACES.
2. SLEEVE AND SEAL ALL WALL, FLOOR, SLAB AND ROOF
PIPE PENETRATIONS WATER TIGHT. PROVIDE FIRE
STOPPING AT EACH PENETRATION THRU A RATED
ASSEMBLY.
3. COORDINATE WORK WITH OTHER TRADES TO MINIMIZE
INTERFERENCES BETWEEN PIPES, DUCTS, ELECTRICAL
SYSTEMS AND STRUCTURES.
4. ALL PLUMBING AND FIRE PROTECTION PIPING TO BE
CONCEALED UNLESS OTHERWISE NOTED.
5. LOCATE FIRE PROTECTION PIPING AS HIGH AS POSSIBLE
AND SUPPORT FROM STRUCTURE. PROVIDE AUXILIARY
DRAINS AT ALL LOW POIINTS.
6. COORDINATE ALL PLUMBING AND FIRE PROTECTION
PIPING WITH ALL OTHER TRADES BEFORE INSTALLATION.
7. ALL VALVES SHALL BE INSTALLED WITH CLEARANCE FOR
OPERATION WITHOUT REMOVING HAND FROM HANDLE.
PUMP SCHEDULE
TAG NO. SERVICE
MAX
SERVICETE
MP (F)
GPM MAX FT. HEAD RPM MAX HP MIN EFF (%) VOLT/PH TYPE
P-1 SUBMERSIBLE SUMP PUMP WITH PIT 160 35 10 1750 3
10 - 120/1/60 SUBMERSIBLE
NOTES:
1. SUMP WATER LEVEL CONTROLLED BY SUMP PUMP FLOAT.
2. ELECTRICAL POWER SUPPLY FROM THE ELEVATOR ELECTRIAL PANEL AT ELEVATOR EQUIPMENT ROOM CLOSE BY.
3. THE WATER COLLECTED ON THE FLOOR OVERFLOW TO THE SUMP PIT TO BE PUMPED OUT.
SCALE: 1/2" = 1'-0"
PLAN VIEWP1
SCALE: 1" = 1'-0"
SECTION VIEWP2
G . R
EE
D
M . T
AN
N
ER
G . R
EE
D
M
EC
H
AN
IC
AL
S U
M P
PU
M
P
PL
AN
P-101
P-101 P2
INSTALL NEW SUMP
PIT IN EXISTING
ELEVATOR PIT P-1
TIE 2" SAN.PIIPE
INTO EXISTING
8" SAN. PIPE
EXISTING 8" SAN. SEWER
FINISH FLOOR
EXISTING ELEVATOR
SHAFT WALL
EXISTING ELEVATOR
PIT WALL
20A
WP
PUMP POWER CORD
PENETRATE ELEVATOR
EQUIPMENT ROOM WALL
120' CKT
PANEL 1A
CKT 41
20A,120V
2 - #12 THHN
1 - #12 GROUND
INTO 3 4" EMT EXISTING ELEVATOR
PIT SLAB
1' -0
" B .T
.F
LOCATE RECEPTACLE ON WALL
CLOSE TO THE POWER CORD
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
IS
SU
E D
AT
E:
SI
ZE
M
AR
K
D
ES
C R
IP
TI
O N
D
AT
E
SHEET ID
ST
C
IV
IL
E
N G
IN
EE
R S
Q U
AR
D
R O
N
L
ST
R
EE
T
B4
BI
LO
XI
, M S
M ay
AN
SI
D
KE
ES
LE
R
A
IR
F O
R C
E
BA
SE
B
IL
O
XI
, M
IS
SI
SS
IP
PI
SU
M P
PU
M
P
PL
AN
B
, B
, B
, B
PR
O
JE
C T
N O
M
AH
G
0%
D
ES
IG
N
S U
BM
IT
TA
L
SCALE: 1/2" = 1'-0"E1
SCALE: 1" = 1'-0"
SECTION VIEWE2
GENERAL ELECTRICAL NOTES
1. CONTRACTOR URGED AND EXPECTED TO FIELD VERIFY
ALL DIMENSIONS AND CONDITIONS PRIOR TO BID AND
START OF CONSTRUCTION. NOTIFY BUYER OF ANY
CONDITIONS DETRIMENTAL TO THE COMPLETION OF THE
WORK AS DESIGNED.
2. THE WORD "PROVIDE" MEANS TO PROVIDE AND INSTALL
UNLESS NOTED OTHERWISE.
3. PROTECT ALL ELEMENTS TO REMAIN SUCH AS EXISTING
UTILITIES, FACILITY, ROADS, CURBS, DRIVES, SIDEWALKS,
METAL CARPORTS, SOLID SOD, ETC. CONTRACTOR TO
RESTORE ANY DAMAGED ELEMENTS TO THEIR ORIGINAL
4. CONDITIONS.
5. CONFINE ALL WORK TO SPECIFIC AREAS AS DESIGNATED
IN THE SCOPE OF WORK AND SCHEDULE.
6. REFER TO MATERIAL SPECIFICATION IN SCOPE OF WORK
FOR REQUIREMENTS AND APPLICATIONS.
7. PRIOR TO CONSTRUCTION, CALL 811 TO LOCATE ALL
UTILITIES, ANY UTILITY ADJUSTMENTS, EXISTING OR
PROPOSED, REQUIRED TO COMPLETE CONSTRUCTION IS
THE RESPONSIBILITY OF THE CONTRACTOR. THIS ITEM
INCLUDES, BUT IS NOT LIMITED TO: THE TEMPORARY
RELOCATION OF EXISTING OVERHEAD POWER LINES. ALL
WORK IN THE VICINITY OF OVERHEAD POWER LINES
SHALL CONFORM TO OSHA REQUIREMENTS AND ANY
OTHER APPLICABLE (LOCAL) SAFETY REQUIREMENTS.
THE CONTRACTOR IS TO REPAIR ANY DAMAGES TO
EXISTING UTILITIES THAT ARE TO REMAIN IN SERVICE
IMMEDIATELY AT NO ADDITIONAL COSTS OR EXPENSE TO
THE GOVERNMENT.
8. ALL ELECTRICAL WORK IS NEW, UNLESS OTHERWISE
NOTED, AND SHALL BE INSTALLED IN ACCORDANCE WITH
THE LATEST EDITION OF THE NEC, NFPA, OSHA IN EFFECT
AT THE START OF THE CONTRACT AND SPECIFICATIONS.
THE CONTRACTOR SHALL PROVIDE ALL NECESSARY
ELECTRICAL EQUIPMENT AND CONNECTIONS INCLUDING
CONTROL WIRING IN CONDUIT SYSTEM TO OTHER
DISCIPLINES' EQUIPMENT AS INDICATED / AS REQUIRED
FOR A COMPLETE, FUNCTIONAL ELECTRICAL CONTROL
SYSTEM. FOR CLARITY, NOT ALL FINAL CONNECTIONS
AND/OR WIRING ARE SHOWN ON THE DRAWINGS.
9. DRAWINGS ARE DIAGRAMMATIC AND DO NOT SHOW ALL
OFFSETS, BENDS, ELBOWS, JUNCTION BOXES, WIRE
TROUGHS, PULL BOXES OR OTHER REQUIRED ELEMENTS
FOR PROPER INSTALLATION OF THE WORK. ALL
NECESSARY MATERIALS NEEDED TO FULFILL THE
PROJECT REQUIREMENTS SHALL BE PROVIDED AT NO
ADDITIONAL COST TO THE GOVERNMENT. SIZES SHALL
BE PER APPLICABLE CODES.
10. THE LOCATIONS OF SWITCHES, PANELS AND OTHER
EQUIPMENT ARE APPROXIMATE. COORDINATE AND
INSTALL THESE ITEMS SO AS TO ELIMINATE
INTERFERENCE WITH DUCTS, PIPES AND ALL OTHER
EQUIPMENT AND UTILITIES. ADJUST MOUNTING HEIGHTS
AND PROVIDE APPROPRIATE MOUNTING HARDWARE AS
REQUIRED.
11. PROVIDE EQUIPMENT GROUNDING TO ALL CIRCUITS,
SIZED AS PER NEC, NFPA, AND AS SHOWN ON THE
DRAWINGS.
12. COMPLY WITH NFPA, UFC, OTHER APPLICABLE CODES
AND AUTHORITY HAVING JURISDICTION OR AS SHOWN ON
THE DRAWINGS FOR MOUNTING HEIGHTS OF ALL
ELECTRICAL EQUIPMENT AND DEVICES. MAINTAIN
MINIMUM WORKING CLEARANCES REQUIRED BY NEC,
NFPA, UNLESS APPROVED IN WRITING.
13. DO NOT DISTURB ANY WIRING WHOSE ORIGIN, FUNCTION
OR UTILITY ARE UNKNOWN WITHOUT PRIOR APPROVAL
FROM THE BUYER. FIELD VERIFY ALL CIRCUITS BEING
IMPACTED PRIOR TO THE START OF WORK.
14. NOTIFY THE BUYER IF A CONDITION PREVENTS THE
INTENT OF THESE PLANS.
15. FOLLOW MANUFACTURER'S WRITTEN INSTRUCTIONS FOR
INSTALLATIONS, UNLESS INDICATED OR SPECIFIED
OTHERWISE. ADVISE THE BUYER AND OBTAIN WRITTEN
DIRECTION FROM THE BUYER IF CONFLICTS EXIST
BETWEEN MANUFACTURERS REQUIREMENTS AND
CONTRACT DOCUMENTS PRIOR TO THE START OF THE
AFFECTED WORK.
16. CONDUCTORS / CONDUIT SIZES LABELED FOR EACH
BRANCH CIRCUIT / FEEDER RUN SHALL BE CONSIDERED
THE SAME FOR ALL DOWNSTREAM RUNS UNTIL THE
SIZES ARE CHANGED OR TERMINATED.
17. PROVIDE A TYPED DIRECTORY IN ALL PANEL BOARDS
CLEARLY DESCRIBING THE LOCATION OF AND TYPE OF
LOAD BEING SERVED FOR ALL CIRCUITS.
18. PROVIDE ENGRAVED PHENOL NAMEPLATES FOR ALL
SWITCHBOARDS, SWITCHGEAR, PASTEBOARDS,
TRANSFER SWITCHES, AND DISCONNECT SWITCHES, USE
COLORS AS PROVIDED IN THE SPECIFICATIONS.
19. THE CONTRACTOR IS RESPONSIBLE FOR PROTECTING
ALL ELECTRICAL EQUIPMENT FROM FOREIGN MATERIAL
DURING CONSTRUCTION.
20. THIS SHEET IS A STANDARD SHEET. CERTAIN SYMBOLS
AND ABBREVIATIONS INDICATED ON THIS SHEET MAY
NOT APPEAR ON THE DRAWINGS.
21. CONTRACTOR WILL BE RESPONSIBLE TO VERIFY THE
BUILDING / STRUCTURE SERVICE VOLTAGES IN ORDER
TO SELECT THE EQUIPMENT NEEDED IN THIS PROJECT
TO WORK PROPERLY. BEFORE CONNECTING THE ANY
EQUIPMENT, THE CONTRACTOR SHALL VERIFY AND TEST
IF THE PROPER VOLTAGE IS SUPPLIED.
22. IAW UFC 3-520 PAR 3.2.5.1(CURRENT EDITION) CIRCUIT
BREAKERS IN NEW PANELS SHALL BE BOLT-ON TYPE,
UNLESS THE EXISTING PANELS ONLY PERMIT PLUG-ON
BREAKERS.
23. WHEN INSTALLING MOTORS AND PUMPS, THE
CONTRACTOR IS RESPONSIBLE TO PROVIDE UNDER THIS
PROJECT THE MOTOR STARTER / CONTROL PANELS AS
REQUIRED BY THE MANUFACTURER.
24. GROUNDING CONDUCTORS FOR SURGE ARRESTERS
SHALL NOT BE RUN IN METAL ENCLOSURES UNLESS THE
METAL RACEWAY IS BONDED TO BOTH ENDS OF THE
GROUNDING CONDUCTOR.
25. WHEN PENETRATING WALLS THAT ARE FIRE RATED, A 2
HOURS MIN. FIRE STOP KIT SEALANT SHALL BE APPLIED
TO SEAL AREA AROUND CONDUIT AND WALL, HIGHER
RATING SHOULD BE USED WHEN WALL IS RATED OVER 2
HOURS.
APPLICABLE CODES
CODES TO BE FOLLOWED INCLUDE BUT ARE NOT LIMITED TO:
UFC 1-200-01: DOD BUILDING CODE
UFC 3 501-01: ELECTRICAL ENGINEERING
UFC 3 520-01: INTERIOR ELECTRICAL SYSTEMS
NFPA 70: NATIONAL ELECTRICAL CODE
IBC: INTERNATIONAL BUILDING CODE