Questions and Answers:

The following questions are derived from the site visit and questions provided through other means.

1. Please provide the quantity of trusses or the spacing of the trusses shown on sheet A6, detail 3 as this information cannot be determined upon review of the bidding documents.

RESPONSE: There will be two trusses; one attached to each of the vertical tubes each side of the opening.

2. See sheet S101. Please provide a base plate detail for the 14" steel pipe columns.

RESPONSE: Use a 1 ½” thick, 24” diameter base plate with 8- 3/4” dia. anchor bolts

3. See sheet S301, section 2. Please identify the vertical members located above the metal roof deck and below the two wide flange steel beams.

RESPONSE: 3” dia. standard steel pipe, supporting the equipment rails.

4. The Specifications Table of Contents lists section as 07 56 10 Fluid Applied Roofing. But, the specs leave out that section jumping from 07 42 13 to 07 60 00. There appear to be no specs for that application. Please provide specification.

RESPONSE: See amendment #2 for updated “Specifications”

5. Would you be able to email me an editable WORD version of the Attachment-10 form included in the Solicitation?

RESPONSE: See attached editable word version of Attachment-10.

6. Is the building going to be pre-fabricated or custom built? Custom Built

7. Is the relocation of the fence and trees part of the project and will the relocation of the fence and tress, be performed by the Government or Contractor? Reference "Specifications" Section 02 41 00 Part 3, paragraph 3.1.3.

8. Will the maximum height be 90 feet?

RESPONSE: Yes. As indicated on the Contract Documents.

9. Will the capacity of the building be 4 people and equipment?

RESPONSE: Per Code, 100/sf per person.

10. Will there be fixed equipment in the building?

RESPONSE: None.

11. Will there be a lavatory in the building?

RESPONSE: No.

12. Can you provide a bidders list/site visit attendees list?

RESPONSE: Only one company authorized release of their name below:

Lord & Son Construction 19 David Street Ft. Walton Beach, FL 32547