SOW_Attch_1_-_Project_Drawing_Package.pdf

PDF 1 MB Posted

Attached to
Repair by Replace HVAC, Satellite Comm Station, B700 Federal contract opportunity
Solicitation number
FA2550-17-R-1021
Issued by
Department of the Air Force Space Command

About this file

SOW Attch 1 - Project Drawing Package

View the file

Other files for this federal contract opportunity

Other files attached to Repair by Replace HVAC, Satellite Comm Station, B700, newest first.
File Type Posted
Wage_Determination.pdf PDF
RFIs_19_Jul_17.pdf PDF
GLEN191001_SOW_-_20_Jul_17.pdf PDF
23_64_10_-_Water_Chillers,_Vapor_Compression_Type.pdf PDF
RFIs_&_Responses_18_Jul_17.pdf PDF
Generator_Fuel_Tank_rules.docx DOCX document
Wage_Determination.pdf PDF
RFIs_and_Responses_GLEN_19-1001_17_Jul_17.pdf PDF
GLEN_19-1001_Site_Visit_Attendance_Sheet_28_Jun_17.pdf PDF
GLEN_19-1001_Site_Visit_Memo_28_Jun_17.pdf PDF
FA2550-17-R-1021_RFP_Repair_HVAC_B700.pdf PDF
SOW_Attch_3_-_AF_Form_66_Submittal_Registry.xls XLS spreadsheet
SOW_Attch_2_-_Specifications.pdf PDF
RFP_Attch_2_-_Wage_Determination.pdf PDF
RFP_Attch_1_-_Statement_of_Work_dated_8_May_17.pdf PDF
Show all 15

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

BELTWAY

BELTWAY

504502200420

B E L T W A Y

504502200420

B E L T W A Y

PARKING

AREA

PARKING

AREA

3A3A

BELTWAYBELTWAY

1B

1A

2B 3B

2A

L A G O O N

P L A C E

1B

1A

2B 3B

2A

L A G O O N

P L A C E

O'MALLEY AVENUE

IRWIN AVENUE

O'MALLEY AVENUE

IRWIN AVENUE

KEPLER AVENUE

KEPLER AVENUE

D

IS

C O V E R E R

S T R E E T

D

IS

C O V E R E R

S T R E E T

S P U T N

IK

S T R E E T

GUARD

HOUSE

LAGOON CIRCLE

640 630

S P U T N

IK

S T R E E T

GUARD

HOUSE

LAGOON CIRCLE

640 630

N A V S T A R

S T R E E T

V A N G U A R D

S T R E E T

N A V S T A R

S T R E E T

V A N G U A R D

S T R E E T

10111011

H

AH

N

AV

EN

U E

H

AH

N

AV

EN

U E

FIELD

ATHLETIC

E N O C H

R O A D

FIELD

ATHLETIC

X X

X X

X X

X XX XX X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X XX X

X X

X X X X X X

VE ST .

X X

X X

X X

X X

X X

X X

X XX X

X X

X X

X X

X X X X X X X X X X X X

XX

X X

PARKING

AREA

AREA

PARKING

OPERATIONAL SPT

PARKING

AREA

50505050

BELTWAY

GALILEO AVE.

BELTWAY

GALILEO AVE.

FALCON PARKWAY

SHOPETTE

P A R K

IN

G

A R E A

FALCON PARKWAY

SHOPETTE

P A R K

IN

G

A R E A

FACILITY

FAL CO N PA RK W AY

Co n . D ra i n Co n . Dr a i n

ASPHAL T

PARKING

PARKING

AREA

AREA

SOFTBALL

FIELD

PARKING

PARKING

AREA

AREA

SOFTBALL

FIELD

Co n. D ra i n

C o n

D ra in

A S P H A L T

C o n D r ai n

FALCON PARKWAY

Co n . D ra i n

710710

B E L T W A Y

B E L T W A Y

CONTRACTOR'S ACCESS ROUTE

CONTRACTOR'S STAGING AREA

VISITOR CENTER

Cheyenne

Wells

Arapahoe

Burlington

Sedalia

Franktown Elizabeth

Elbert

Forest Black

Municipal Airport Colorado Springs

La

Veta

Aguilar

Pryor

Beulah

Colorado City

Springs Colorado

Canon

City

Greenwood

Penrose

Carson Fort

Pikes

Peak

Monument

Academy

U.S. Air

Force

Lake Palmer

Larkspur

Rock

Castle

Thatcher

Tyrone

Model

Rocky

Ford

Fowler

Delhi

Timpas 109

Crowley

Hawley

Swink

La

Junta

City

Hasty

McClave

Ninaview

Toonerville

Lyon Ft.

Wiley Bristol

SCHRIEVER AFB

Arlington

Karval

Boyero

Hugo

Punkin

North

Avondale Pueblo

Boone

Ellicott

AFB

Peterson

Yoder

Ordway Sugar

Center

Agate

Ramah

Rush

Peyton

Falcon

Calhan

Kiowa

Simla

Matheson

Kutch

Limon

Genoa

Wild

EadsHaswell

Horse 40 Kit

Carson

Seibert

Vona

Aroya

Arriba

Flagler

Stratton

Bethune

Watkins

Parker

Airport

Denver

Int.

Greenley

Denver

Boulder

Golden

Aurora

Littleton

Englewood

Brighton

Longmont

Loveland

Fort

Collins

Lupton Fort

Fleming

Woodrow

Merino Atwood

Sterling

Willard

Lindon

Hoyt

Bennett

Deer Trail

Strasburg

Valley Prospect

Last

Chance36

Wiggins

Roggen76

Morgan Fort

Snyder

Brush

Stoneham

Raymer New

Eckley

Cope

Anton

Kirk

Joes

Idalia

Akron

Platner

Otis

Yuma

K A N S A S

Sheridan Lake

C O L O R A D O 36

N E B R A S K A

N

N

D E

S C

R

IP

TI

O

N M

A R

K D

A

TE

A P

P R

D E

S

IG

N E

D B

Y

D W

N B

Y

S U

B M

IT

TE

D B

Y

FI

LE

N A

M E

S

IZ

E

P

LO

T S

C A

LE

P

LO

T D

A

TE

FI

LE

N

U M

B E

R

C O

N

TR

A C

T N

O

S O

LI

C

IT

A

TI

O

N N

O

D A

TE

D E

S C

R

IP

TI

O

N M

A R

K D

A

TE

A P

P R

SHEET

IDENTIFICATION

C K

D B

Y

A N

S I D

A S

N O

TE

D

ME

O MC

S P A C N

D A

D

2 3

C

A

B D A

V

ID

A . L

U K

E , P

.E

AI

R

F O

R C

E

SP

AC

E

C O

M M

AN

D

SC

H

R

IE

VE

R

A

IR

F O

R C

E B

A

SE

C O

LO

R

A D

O

PROJECT AREA MAP

NO SCALE

VICINITY MAP

NO SCALE

NOTES:

1. THE CONTRACTOR'S STORAGE AREA, AND ANY OTHER AREAS DISTURBED BY

CONSTRUCTION ACTIVITIES NOT INDICATED TO BE OTHERWISE SURFACED, SHALL

BE RESTORED TO THEIR ORIGINAL CONDITION BY FINE GRADING AND SEEDING IN

ACCORDANCE WITH SPECIFICATIONS.

REPAIR BY REPLACE HVAC SYSTEM, B700

SCHRIEVER AIR FOR BASE, COLORADO

GLEN 19-1001

R

EP

A

IR

B Y

R

EP

LA

C

E H

VA

C

S

YS

TE

M

, B

SC

H R

IE

VE

R A

IR

F

O R

B A

SE

, C

O

LO

R A

D O

G

LE

N

9-

PROJECT SITE

BUILDING 700

/2

7/

:1 5:

P

M

G-100

E . B

R A

TT

E . B

R A

TT

K . B

R E

S

LI

N

C O

V E

R S

H E

E T

A N

D D

R A

W

IN

G

IN

D E

X

100% ISSUED FOR CONSTRUCTION

O

C T

G

LE

N

9-

FA

-1

1- D

-0

DRAWING INDEX

DRAWING NO. DRAWING TITLE

G-100 COVER SHEET AND DRAWING INDEX

DM101 MECHANICAL DEMOLITION PLAN, ABBREVIATIONS AND LEGEND

M-101 MECHANICAL FLOOR PLAN, ABBREVIATIONS, AND LEGEND

M-201 MECHANICAL SCHEDULES

E-001 ELECTRICAL LEGEND AND ABBREVIATIONS

ED101 ELECTRICAL DEMOLITION PLAN

E-101 ELECTRICAL POWER SYSTEM FLOOR PLAN

(E) CU-2 (E) CU-1

(E) C-1

(E) C-2

GENERAL SYMBOLS

ADJ ADJUSTABLE

AFF ABOVE FINISHED FLOOR

BHP BRAKE HORSEPOWER

BTUH BTU PER HOUR

CD CONDENSATE DRAIN

CHWR CHILLED WATER RETURN

CHWS CHILLED WATER SUPPLY

DB DRY BULB

dB DECIBELS

DDC DIRECT DIGITAL CONTROL

DEG DEGREES

DEG F DEGREES FAHRENHEIT

ESP EXTERNAL STATIC PRESSURE

EWT ENTERING WATER TEMPERATURE

°F DEGREES FAHRENHEIT

FLA FULL LOAD AMPS

FPM FEET PER MINUTE

FT FEET

FT HD FEET HEAD

GA GAUGE

GPM GALLONS PER MINUTE

HP HORSEPOWER

HR HOUR

Hz HERTZ

IN W.G. INCHES OF WATER GAUGE

kPa KILOPASCALS kW KILOWATT

LVG LEAVING

LWT LEAVING WATER TEMPERATURE

MAX MAXIMUM

MCA MINIMUM CIRCUIT AMPACITY

MBH THOUSAND BTU PER HOUR

MIN MINIMUM

NC NORMALLY CLOSED

NO NORMALLY OPEN

NTS NOT TO SCALE

Pa PASCALS

PD PRESSURE DROP

PH PHASE

PRV PRESSURE REDUCING VALVE

PSI POUNDS PER SQUARE INCH

PSIG PSI GAUGE

RLA RUNNING LOAD AMPS

RPM REVOLUTIONS PER MINUTE

SP STATIC PRESSURE

TDH TOTAL DYNAMIC HEAD

TEMP TEMPERATURE

TSP TOTAL STATIC PRESSURE

TYP TYPICAL

UNO UNLESS NOTED OTHERWISE

WC WATER COLUMN

WG WATER GAUGE

MECHANICAL ABBREVIATIONS

GENERAL

EQUIPMENT

CH CHILLER

CHWP CHILLED WATER PUMP

CWP CONDENSER WATER PUMP

P PUMP

MECHANICAL LEGEND

HYDRONIC PIPING

CHWS CHILLED WATER SUPPLY

CHWR CHILLED WATER RETURN

VALVE, SEE SPECIFICATIONS FOR

VALVE TYPE

PRESSURE REDUCING VALVE

FLEXIBLE CONNECTION

TEST PLUG

PRESSURE GAUGE

MANUAL AIR VENT

PIPE BREAK

DIRECTION OF FLOW

PIPE UP

PIPE DOWN

PIPE T DOWN

PIPE T UP

PIPE CAP

UNION

REDUCER

PIPE ANCHOR

PIPE GUIDE

STRAINER

STRAINER WITH VALVE AND HOSE

CONNECTION

THERMOMETER OR SIGHT GLASS

RL REFRIGERANT LIQUID

RS REFRIGERANT SUCTION

PIPE SLOPE

CONNECT NEW TO EXISTING

AT THIS POINT

DEMOLISH TO THIS POINT

10 KEYNOTE

EQUIPMENT DESIGNATIONAHU-1

CONTROLS SYMBOLS

CONTROLS

BAS BUILDING AUTOMATION SYSTEM

BMS BUILDING MANAGEMENT SYSTEM

DDC DIRECT DIGITAL CONTROL

EMCS ENERGY MANAGEMENT CONTROL SYSTEM

°F DEGREES FAHRENHEIT

MAX MAXIMUM

MIN MINIMUM

NC NORMALLY CLOSED

NO NORMALLY OPEN

NTS NOT TO SCALE

PPM PARTS PER MILLION

PSI POUNDS PER SQUARE INCH

TYP TYPICAL

UMCS UTILITY MONITORING AND CONTROL SYSTEM

UPS UNINTERRUPTED POWER SUPPLY

WC WATER COLUMN

EPT

DIFFERENTIAL PRESSURE TRANSMITTER

HIGH-LOW TEMPERATURE THERMOSTAT

FLOW PROVING SWITCH DIFFERENTIAL

PRESSURE

FLUID FLOW TRANSMITTER

FLUID FLOW MEASURING DEVICE

FLOW PROVING SWITCH PADDLE TYPE

CURRENT SENSING RELAY

RELAY

TEMPERATURE SENSOR

DIFFERENTIAL PRESSURE SWITCH

ELECTRIC PNEUMATIC TRANSDUCER

DAMPER ACTUATOR END SWITCH

TS

FPS

CSR

R

PDS

FMT

FPS

ES

LLHL

DPT

DI

DIGITAL OUTPUT

DIGITAL INPUT

ANALOG INPUT

DO

AI

AO

ANALOG OUTPUT

ELECTRICAL WIRING CONDUCTORS AS

REQUIRED

CONTROL PANEL -

MOUNT CONTROL PANEL AT 4'8" ABOVE FLOOR TO

CENTER OF CONTROL PANEL

CP

EMERGENCY POWER OFF SWITCH -

MOUNT BOTTOM AT 4'-0" ABOVE FLOOR

EPO

CONTROL PANEL

D E

S C

R

IP

TI

O

N M

A R

K D

A

TE

A P

P R

D E

S

IG

N E

D B

Y

D W

N B

Y

S U

B M

IT

TE

D B

Y

FI

LE

N A

M E

S

IZ

E

P

LO

T S

C A

LE

P

LO

T D

A

TE

FI

LE

N

U M

B E

R

C O

N

TR

A C

T N

O

S O

LI

C

IT

A

TI

O

N N

O

D A

TE

D E

S C

R

IP

TI

O

N M

A R

K D

A

TE

A P

P R

SHEET

IDENTIFICATION

C K

D B

Y

A N

S I D

A S

N O

TE

D

ME

O MC

S P A C N

D A

D

2 3

C

B D A

V

ID

A . L

U K

E , P

.E

AI

R

F O

R C

E

SP

AC

E

C O

M M

AN

D

SC

H

R

IE

VE

R

A

IR

F O

R C

E B

A

SE

C O

LO

R

A D

O

R

EP

A

IR

B Y

R

EP

LA

C

E H

VA

C

S

YS

TE

M

, B

SC

H R

IE

VE

R A

IR

F

O R

B A

SE

, C

O

LO

R A

D O

G

LE

N

9-

/2

7/

:1 5:

P

M

DM101

E . B

R A

TT

E . B

R A

TT

K . B

R E

S

LI

N

M E

C H

A N

IC

A

L D

E M

O

LI

TI

O

N P

LA

N

A

B B

R E

V

IA

TI

O

N S

A N

D L

E G

E N

D

100% ISSUED FOR CONSTRUCTION

O

C T

G

LE

N

9-

FA

-1

1- D

-0

SCALE: 1/8" = 1'-0"

MECHANICAL DEMOLITION FLOOR PLAN

SHEET NOTES:

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS

PRIOR TO ORDERING EQUIPMENT OR ANY FABRICATION.

IF IT BECOMES NECESSARY DURING DEMOLITION TO

TEMPORARILY REMOVE ANY EQUIPMENT, PIPING, ETC. WHICH

IS NOT SPECIFICALLY NOTED TO BE REMOVED (THEREBY

IMPLYING THAT THEY ARE TO BE LEFT FOR FUTURE USE), THE

CONTRACTOR SHALL REINSTALL SAID SYSTEMS TO FULLY

OPERABLE CONDITION IN THEIR ORIGINAL LOCATIONS.

FILE METHOD OF PROCEDURE (MOP) DOCUMENTATION AT

LEAST THREE WEEKS PRIOR TO ANY SYSTEM INTERRUPTION,

SHUTDOWN, DEMOLITION OR CHANGE-OVER.

ANY DAMAGE TO THE OWNER'S OR TENANT'S PROPERTY, TO

THE STRUCTURE OR BUILDING, OR TO EQUIPMENT RESULTING

FROM THE CONTRACTOR'S OPERATIONS SHALL BE REPAIRED

OR REPLACED BY THE CONTRACTOR TO THE SATISFACTION

OF THE OWNER WITHOUT ADDITIONAL COST TO THE OWNER.

REPAIR OR REPLACEMENT SHALL, AS A MINIMUM, EQUAL

EXISTING CONDITIONS.

ASBESTOS IS NOT EXPECTED BE PRESENT IN THE BUILDING.

IF DURING THE COURSE OF THE WORK MATERIAL WHICH MAY

CONTAIN ASBESTOS IS DISCOVERED, STOP WORK

IMMEDIATELY AND NOTIFY THE COTR.

THERE SHALL BE NO INTERRUPTION TO THE BUILDING

CONTROL SYSTEM.

REFER TO PROJECT SPECIFICATIONS FOR SITE ACCESS

RESTRICTIONS AND ESCORT PROCEDURES.

CONTRACTOR SHALL PREPARE DETAILED STEP-BY-STEP

CONSTRUCTION SCHEDULE DETAILING ALL WORK TASKS AND

OPERATIONS REQUIRED TO ACCOMPLISH PROJECT WITHOUT

CONTROL SYSTEM INTERRUPTION, SUBJECT TO NOTES

ABOVE. CONSTRUCTION SCHEDULE DETAILING SHALL BE

SUBMITTED CONCURRENT WITH MOBILIZATION AND

EQUIPMENT SUBMITTALS. SEE SPECIFICATION SECTION 01 33

00 FOR SUBMITTAL REQUIREMENTS.

CONTRACTOR SHALL COORDINATE TEMPORARY CHILLER

INSTALLATION WITH TEMPORARY CHILLER CONNECTION

INSTALLATION AND EXISTING CHILLER/CONDENSING UNIT

DEMOLITION. DOWNTIME FOR EACH CHILLER SHALL BE

MINIMIZED BY COORDINATING THE INSTALLATION OF ALL

TEMPORARY CONNECTIONS AND PIPING PRIOR TO TAKING

EACH CHILLER OFFLINE.

SEE ELECTRICAL PLANS FOR POWER REQUIREMENTS.

KEYNOTES:

REMOVE EXISTING REFRIGERANT SUCTION LINE.

REMOVE EXISTING WAVEFORM, REPLACE WITH WAVEFORM

SIZED FOR 2-1/2". COORDINATE DEMOLITION WITH MISSION

AND RECERTIFY.

REMOVE EXISTING CHILLER. PREPARE EXISTING CHILLED

WATER AND REFRIGERANT LIQUID PIPES FOR

CONNECTIONS TO NEW CHILLER.

REMOVE EXISTING CONDENSING UNIT. PREPARE

REFRIGERANT LIQUID PIPES FOR CONNECTIONS TO NEW

CONDENSING UNIT.

TEMPORARY 3" CHILLER CONNECTION THROUGH WALL.

CONTRACTOR SPECIALIZING IN HEMP BARRIER

INSTALLATION SHALL BE UTILIZIED. PROVIDE PERMANENT

PENETRATION WITH WAVEFORM AND VALVED

CONNECTIONS ON EACH END. PENETRATION SHALL

REQUIRE RECERTIFICATION OF HEMP BARRIER.

CONTRACTOR SHALL COORDINATE CONSTRUCTION AND

RECERTIFICATION WITH AIR FORCE MISSION

REQUIREMENTS. REFER TO SHEET M-1.

LOCATE TEMPORARY CHILLER OUTSIDE CHILLER YARD.

COORDINATE EQUIPMENT LOCATION AND TEMPORARY

PIPING WITH BUILDING SERVICES MANAGER.

EXISTING TEMPORARY CHILLER CONNECTIONS ON CHILLED

WATER PIPING. COORDINATE LOCATION IN THE FIELD.

04 8 16268

SCALE: 1/8"=1'-0"

N

1 1/2" RL

1 1/2" RL

1 1/2" RL

1 1/2" RLMECHANICAL VAULT

21 TUNNEL

MECHANICAL

MENS

KITCHEN

CORRIDOR

WOMENS

(E)

PUMP

(E)

PUMP(E)

PUMP

(E)

PUMP

CHWR

CHWS

CH-1

CH-2

CU-2 CU-1

2 1/2" RGH

2 1/2" RGH

2 1/2" RGH

2 1/2" RGH

(E) (E)

(E) (E)

D E

S C

R

IP

TI

O

N M

A R

K D

A

TE

A P

P R

D E

S

IG

N E

D B

Y

D W

N B

Y

S U

B M

IT

TE

D B

Y

FI

LE

N A

M E

S

IZ

E

P

LO

T S

C A

LE

P

LO

T D

A

TE

FI

LE

N

U M

B E

R

C O

N

TR

A C

T N

O

S O

LI

C

IT

A

TI

O

N N

O

D A

TE

D E

S C

R

IP

TI

O

N M

A R

K D

A

TE

A P

P R

SHEET

IDENTIFICATION

C K

D B

Y

A N

S I D

A S

N O

TE

D

ME

O MC

S P A C N

D A

D

2 3

C

B D A

V

ID

A . L

U K

E , P

.E

AI

R

F O

R C

E

SP

AC

E

C O

M M

AN

D

SC

H

R

IE

VE

R

A

IR

F O

R C

E B

A

SE

C O

LO

R

A D

O

R

EP

A

IR

B Y

R

EP

LA

C

E H

VA

C

S

YS

TE

M

, B

SC

H R

IE

VE

R A

IR

F

O R

B A

SE

, C

O

LO

R A

D O

G

LE

N

9-

/2

7/

:1 5:

P

M

M-101

E . B

R A

TT

E . B

R A

TT

K . B

R E

S

LI

N

M E

C H

A N

IC

A

L

FL

O O

R P

LA

N

, A B

B R

E V

IA

TI

O N

S

A N

D L

E G

E N

D

100% ISSUED FOR CONSTRUCTION

O

C T

G

LE

N

9-

FA

-1

1- D

-0

SCALE: 1/8" = 1'-0"

MECHANICAL FLOOR PLAN

04 8 16268

SCALE: 1/8"=1'-0"

N

SHEET NOTES:

KEYNOTES:

TEMPORARY CHILLER CONNECTION. CONTRACTOR SPECIALIZING IN

HEMP BARRIER INSTALLATION SHALL BE UTILIZIED. PROVIDE

PERMANENT PENETRATION WITH WAVEFORM AND VALVED

CONNECTIONS ON EACH END. PENETRATION SHALL REQUIRE

RECERTIFICATION OF HEMP BARRIER. CONTRACTOR SHALL

COORDINATE CONSTRUCTION AND RECERTIFICATION WITH AIR

FORCE MISSION REQUIREMENTS.

THOROUGHLY CLEAN EXISTING REFRIGERANT LIQUID LINES.

PRESSURE TEST PIPING AT 125% CHILLER OPERATING PRESSURE.

REPAIR/REPLACE INSULATION ON REFRIGERANT LINES.

NEW REFRIGERANT LINE THROUGH HEMP BARRIER. INSULATE

REFRIGERANT LINES AS REQUIRED PER MANUFACTURER. HEMP

BARRIER PENETRATION SHALL BE INSTALLED PER MIL STD 188-125-1.

RECONNECT (E) CHILLED WATER SUPPLY AND RETURN PIPING TO

CHILLER. NEW CHILLERS SHALL BE INCORPORATED INTO EXISTING

HSQ CONTROLS SYSTEM.

EXISTING EQUIPMENT PAD TO REMAIN. PAD SHALL BE EXTENDED AS

REQUIRED TO ACCOMMODATE NEW CONDENSING UNIT. REFER TO

DETAIL 2, M201.

RECONNECT NEW AND EXISTING REFRIGERANT LINES TO

CONDENSING UNITS. REATTACH EXISTING CONTROLS BETWEEN

CHILLER AND CONDENSING UNITS.

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS

PRIOR TO ORDERING EQUIPMENT OR ANY FABRICATION.

IF IT BECOMES NECESSARY DURING DEMOLITION TO

TEMPORARILY REMOVE ANY EQUIPMENT, PIPING, ETC. WHICH

IS NOT SPECIFICALLY NOTED TO BE REMOVED (THEREBY

IMPLYING THAT THEY ARE TO BE LEFT FOR FUTURE USE), THE

CONTRACTOR SHALL REINSTALL SAID SYSTEMS TO FULLY

OPERABLE CONDITION IN THEIR ORIGINAL LOCATIONS.

FILE METHOD OF PROCEDURE (MOP) DOCUMENTATION AT

LEAST THREE WEEKS PRIOR TO ANY SYSTEM INTERRUPTION,

SHUTDOWN, DEMOLITION OR CHANGE-OVER.

ANY DAMAGE TO THE OWNER'S OR TENANT'S PROPERTY, TO

THE STRUCTURE OR BUILDING, OR TO EQUIPMENT RESULTING

FROM THE CONTRACTOR'S OPERATIONS SHALL BE REPAIRED

OR REPLACED BY THE CONTRACTOR TO THE SATISFACTION

OF THE OWNER WITHOUT ADDITIONAL COST TO THE OWNER.

REPAIR OR REPLACEMENT SHALL, AS A MINIMUM, EQUAL

EXISTING CONDITIONS.

ASBESTOS IS NOT EXPECTED BE PRESENT IN THE BUILDING.

IF DURING THE COURSE OF THE WORK MATERIAL WHICH MAY

CONTAIN ASBESTOS IS DISCOVERED, STOP WORK

IMMEDIATELY AND NOTIFY THE COTR.

THERE SHALL BE NO INTERRUPTION TO THE BUILDING

CONTROL SYSTEM.

REFER TO PROJECT SPECIFICATIONS FOR SITE ACCESS

RESTRICTIONS AND ESCORT PROCEDURES.

CONTRACTOR SHALL PREPARE DETAILED STEP-BY-STEP

CONSTRUCTION SCHEDULE DETAILING ALL WORK TASKS AND

OPERATIONS REQUIRED TO ACCOMPLISH PROJECT WITHOUT

CONTROL SYSTEM INTERRUPTION, SUBJECT TO NOTES

ABOVE. CONSTRUCTION SCHEDULE DETAILING SHALL BE

SUBMITTED CONCURRENT WITH MOBILIZATION AND

EQUIPMENT SUBMITTALS. SEE SPECIFICATION SECTION 01 33

00 FOR SUBMITTAL REQUIREMENTS.

CONTRACTOR SHALL COORDINATE TEMPORARY CHILLER

INSTALLATION WITH TEMPORARY CHILLER CONNECTION

INSTALLATION AND EXISTING CHILLER/CONDENSING UNIT

DEMOLITION. DOWNTIME FOR EACH CHILLER SHALL BE

MINIMIZED BY COORDINATING THE INSTALLATION OF ALL

TEMPORARY CONNECTIONS AND PIPING PRIOR TO TAKING

EACH CHILLER OFFLINE.

SEE ELECTRICAL PLANS FOR POWER REQUIREMENTS.

CONTRACTOR SHALL

TAKE PRECAUTIONS TO

PREVENT WARPING THE

HEMP SHIELD & DAMAGING

EXISTING PENETRATIONS

COUPLING,

TYPICAL

NEW PENETRATION

NEW PIPE THROUGH

EXISTING PIPE, TYP

OF (2)

BUSHING AS

REQUIRED

REMOVE ACOUSTIC PANEL

& INSULATION DURING

PLATE MODIFICATION.

REINSTALL ACOUSTIC PANEL

& INSULATION WHEN TESTING IS

COMPLETE.

(E) HEMP

SHIELDING

EXISTING PENETRATIONS

AND PIPING

COPPER

PIPE

BRASS PIPE

BRAZE

BRAZE

EXISTING PENETRATIONS

AND PIPING

(E) PENETRATION

PLATE

PRIOR TO MODIFYING HEMP SHIELD:

1. COMPLETE AF FORM 19.

2. TEST EXISTING SHIELD INTEGRITY IN THE

AREA OF HTE MODIFICATION. SEE

SPECIFICATION FOR TESTING

REQUIREMENTS.

AFTER MODIFICATIONS TO HEMP SHIELD ARE

COMPLETE:

1. RETEST SHIELD INTEGRITY IN AREA OF

MODIFICATION.

2. PERFORM ANY REQUIRED REPAIRS TO

RESTORE HEMP SHIELD TO ORIGINAL

PERFORMANCE.

3. RETEST SHIELD INTEGRITY.

BRAZE

1/4"

1/4"

1/4"

CONDUCTIVE METALLIC FITTING,

TYPICAL

CONDUCTIVE METALLIC FITTING,

TYPICAL

CONDUCTIVE METALLIC

FITTING,

TYPICAL

LENGTH OF STRAIGHT PIPE MUST BE

AT LEAST FIVE (5) TIMES THE PIPE

DIAMETER, TYPICAL ALL INSTANCES.

EXISTING FOUNDATION PAD

ROUGHEN SURFACE TO 1/4" AMPLITUDE.

CLEAN SURFACE & AND APPLY BONDING

AGENT PER MFR INSTRUCTIONS PRIOR

TO POURING CONCRETE

DRILL & EPOXY REINF BARS W/

SIMPSON-STRONGTIE SET-XP EPOXY

OR EQUAL. EMBED 5" MIN INTO

EXISTING FOUNDATION PAD

V E

R

IF

Y

8" F

IE

LD 4"

#4 @ 12" O.C. LOCATE

MID-HEIGHT OF SLAB

TYP

2" CLR

PER PLAN

CONCRETE REQUIREMENTS:

A. PER ACI 318.

B. MAXIMUM CONCRETE COMPRESSIVE STRENGTH, F'c = 4,500 PSI.

C. MAXIMUM WATER-CEMENT RATIO, W/C = 0.45.

D. MODERATE FREEZE/THAW EXPOSURE CATEGORY, F1.

E. MAXIMUM SLUMP = 2" TO 4" PRIOR TO ADDITION OF ADMIXTURES.

F. MAXIMUM AGGREGATE SIZE = 3/4".

G. AIR-ENTRAINMENT PERCENTAGE = 5% TO 7%.

H. ADMIXTURES:

- AIR-ENTRAINING PER ASTM C260.

- ACCELERATING PER ASTM C494, TYPE C OR E.

- FLY ASH/POZZOLANS PER ASTM C618.

- WATER-REDUCER OR RETARDER PER ASTM C494; TYPE A, B OR D.

- HIGH RANGE WATER REDUCER (HRWR) PER ASTM C494, TYPE F OR G.

INSIDE HEMP BOUNDARY

OUTSIDE HEMP BOUNDARY

HEMP BOUNDARY

REMOTE

CONDENSING UNIT

CONTROL PANEL

DIGITAL-TO-

PNEUMATIC

CONVERTER

CONDENSING UNIT

PNEUMATIC-

TO-DIGITAL

CONVERTER

PNEUMATIC

TUBING

NOTE: THIS DETAIL IS DIAGRAMMATIC IN

NATURE AND MAY NOT REPRESENT ALL

EQUIPMENT/COMPONENTS REQUIRED.

D E

S C

R

IP

TI

O

N M

A R

K D

A

TE

A P

P R

D E

S

IG

N E

D B

Y

D W

N B

Y

S U

B M

IT

TE

D B

Y

FI

LE

N A

M E

S

IZ

E

P

LO

T S

C A

LE

P

LO

T D

A

TE

FI

LE

N

U M

B E

R

C O

N

TR

A C

T N

O

S O

LI

C

IT

A

TI

O

N N

O

D A

TE

D E

S C

R

IP

TI

O

N M

A R

K D

A

TE

A P

P R

SHEET

IDENTIFICATION

C K

D B

Y

A N

S I D

A S

N O

TE

D

ME

O MC

S P A C N

D A

D

2 3

C

B D A

V

ID

A . L

U K

E , P

.E

AI

R

F O

R C

E

SP

AC

E

C O

M M

AN

D

SC

H

R

IE

VE

R

A

IR

F O

R C

E B

A

SE

C O

LO

R

A D

O

R

EP

A

IR

B Y

R

EP

LA

C

E H

VA

C

S

YS

TE

M

, B

SC

H R

IE

VE

R A

IR

F

O R

B A

SE

, C

O

LO

R A

D O

G

LE

N

9-

/2

7/

:1 5:

P

M

M-201

E . B

R A

TT

E . B

R A

TT

K . B

R E

S

LI

N

M E

C H

A N

IC

A

L S

C H

E D

U

LE

S

100% ISSUED FOR CONSTRUCTION

O

C T

G

LE

N

9-

FA

-1

1- D

-0

CONDENSING UNIT SCHEDULE

PLAN

MARK

ASSOCIATED

UNIT

MINIMUM COOLING

CAPACITY (MBH)

AMBIENT AIR

TEMPERATURE (DEG F)

NUMBER

CIRCUITS FLUID

FANS ELECTRICAL BASIS OF

DESIGN REMARKSNUMBER FLA (EA) VOLT/PH/HZ MCA MOCP

CU-1 CH-1 1500 95 2 R134A 10 3.3 460/3/60 27.2 35 TRANE 1, 2, 3, 4

CU-2 CH-2 1500 95 2 R134A 10 3.3 460/3/60 27.2 35 TRANE 1, 2, 3, 4

WATER COOLED CHILLER SCHEDULE

PLAN

MARK

CAPACITY

(TONS)

COOLING

CAPACITY

COOLING EFF.

(kW/TON)

EVAPORATOR COMPRESSOR ELECTRICAL

BASIS OF DESIGN REMARKSFLUID

FLUID FLOW

(GPM)

ENT FLUID

TEMP (DEG F)

LEV FLUID

TEMP (DEG F)

FLUID P.D.

(FT)

FOULING

FACTOR NUMBER RLA (EA) LRA (EA) VOLT/PH/HZ MCA MOCP

CH-1 120 101.7 1.352 WATER 217 54 42 13 0.0001 2 100 184 460/3/60 211 300 TRANE RTUD 120 HE 1, 2, 3, 4, 5 CH-2 120 101.7 1.352 WATER 217 54 42 13 0.0001 2 100 184 460/3/60 211 300 TRANE RTUD 120 HE 1, 2, 3, 4, 5

REMARKS:

1. DESIGN CONDITIONS: ALTITUDE 6300 FT, -15 DEG F OUTDOOR AIR

2. PNEUMATIC CONTROL INTERFACE BETWEEN CHILLER AND CONDENSER. NO MICROPROCESSOR-BASED EQUIPMENT LOCATED OUTDOORS. CONTROLS SHALL MATCH EXISTING HSQ CONTROLS.

PROVIDE ONE FULL WEEK OF FACTORY STARTUP ASSISTANCE TO ENSURE CONTROLS ARE OPERATING PROPERLY.

3. TEMPORARY CHILLER SHALL BE CAPABLE OF MEETING DESIGN FLUID FLOW OF CH-1 AT SCHEDULED DELTA T, AND SHALL INCLUDE PUMP CAPABLE OF 70 FT HEAD AT THAT FLOW.

4. SPECIFICATION TYPE "C" SPRING ISOLATORS ON CHILLER.

5. PROVIDE ALL ACCESSORIES REQUIRED TO UPGRADE CHILLERS TO NEW REFRIGERANT, INCLUDING REFRIGERANT PUMPS, IF APPLICABLE.

REMARKS:

1. DESIGN CONDITIONS: ALTITUDE 6300 FT, -15 DEG F OUTDOOR AIR. PROVIDE LOW AMBIENT KIT.

2. PNEUMATIC CONTROL INTERFACE BETWEEN CHILLER AND CONDENSER. NO MICROPROCESSOR-BASED EQUIPMENT LOCATED OUTDOORS. CONTROLS SHALL MATCH EXISTING HSQ CONTROLS. PROVIDE ONE FULL WEEK OF FACTORY STARTUP ASSISTANCE TO ENSURE CONTROLS ARE OPERATING PROPERLY.

3. PROVIDE GFCI CONVENIENCE OUTLET ON UNIT.

4. UNIT-MOUNTED CONTROLS SHALL INCLUDE A SURGE PROTECTION DEVICE ON EACH UNIT. DEVICE SHALL BE LITTELFUSE INDUSTRIAL HIGH-ENERGY VARISTOR OR SIMILAR.

REFER TO ELECTRICAL DRAWINGS FOR MORE DETAIL.

12" = 1'-0"1 HEMP PENETRATION DETAIL

1" = 1'-0"2

EXISTING FOUNDATION PAD

EXTENSION

12" = 1'-0"3

DIGITAL TO PNEUMATIC

CONTROLS DETAIL

MOLDED CASE CIRCUIT BREAKER, FIXED TRIP.

THREE POLE UNLESS DESIGNATED "1P" OR "2P"

MOLDED CASE CB OF A GIVEN FRAME SIZE

WITH ADJUSTABLE TRIP SETTINGS

NORMALLY OPEN MOMENTARY PUSHBUTTON

NORMALLY CLOSED MOMENTARY PUSHBUTTON

NORMALLY OPEN CONTACTS

NORMALLY CLOSED CONTACTS

ELECTRICAL METER

FUSE, SIZE AS INDICATED

SURGE ARRESTOR - VOLTAGE RATING AND

CLASS AS NOTED

GROUND CONNECTION - TO STANDARD ROD

TYPE ELECTRODE TO NEAREST STRUCTURE STEEL

(#6 MIN. CONDUCTOR IF NOT SHOWN)

SS

ONE-LINE DIAGRAM SYMBOLS

POWER TRANSFORMER, DELTA-WYE

CONFIGURATION

MOTOR - EQUIPMENT SCHEDULE IDENTIFICATION AS SHOWN

MOTOR - HORSE POWER IDENTIFIED AS SHOWN

M

FUSED DISCONNECT SWITCH, SIZE AND TYPE AS INDICATED IN

SCHEDULE

DISCONNECT SWITCH, SIZE AND TYPE AS INDICATED IN SCHEDULE

F

DISCONNECT SWITCH, FURNISHED WITH EQUIPMENT

MOTOR STARTER, SIZE AND TYPE AS INDICATED IN SCHEDULE

MOTOR STARTER, FURNISHED WITH EQUIPMENT

COMBINATION MOTOR STARTER w/EXTERNALLY

OPERATED DISCONNECT

COMBINATION MOTOR STARTER w/EXTERNALLY

OPERATED DISCONNECT, FURNISHED WITH EQUIPMENT

VFD VARIABLE FREQUENCY DRIVE

SHUNT TRIP SWITCH WITH SAFETY COVERKIRK KEY INTERLOCK ST

CEILING MOUNTED LUMINAIRE

SINGLE POLE SWITCH

MANUAL STARTER WITH THERMAL OVERLOADS

THREE WAY SWITCH

FOUR WAY SWITCH

DIMMER SWITCH

THREE SPEED, FOUR POSITION FAN CONTROL

SWITCH RATED FOR NO. OF FANS INDICATED

OCCUPANCY SENSOR0

F

D

S T0

ELECTRICAL PANELBOARD.

TELEPHONE TERMINAL BOARD (PLYWOOD BACKBOARD)

DATA OUTLET, DUPLEX, 18" AFF, UNLESS NOTED OTHERWISE.

DATA OUTLET, 18" AFF, UNLESS NOTED

OTHERWISE. "2" DENOTES DUPLEX JACK.

TELEPHONE OUTLET, 18" AFF, UNLESS NOTED OTHERWISE.

DATA OUTLET FOR GFGI IP ADDRESSABLE CCTV CAMERA (RISER)

DATA OUTLET, MOUNTED IN RECESSED FLOOR BOX

C

X X

MODULAR TELEPHONE/DATA JACKS, 18" AFF, UNLESS

NOTED OTHERWISE. (2-TELEPHONE, 2-DATA)

CATV OUTLET, 18" AFF, UNLESS NOTED OTHERWISE.

"2" DENOTES DUPLEX JACK.

TELEPH0NE AND DATA CABLES (x = NUMBER OF CABLES)

ROUTED TO A JUNCTION BOX FOR MODULAR FURNITURE.

X

S P

S P

MI

SP-

V

SI-

ICM

IC

RECESSED FLOOR JUNCTION BOX WITH BLANK FACE PLATE FOR

MODULAR FURNITURE (x = NUMBER OF CABLES).

FLUSH MOUNTED CEILING SPEAKER - PAGING SYSTEM

HORN TYPE SPEAKER - PAGING SYSTEM, HEIGHT AS

INDICATED ON FLOOR PLANS.

MICROPHONE INPUT PLATE, 18" AFF.

WALL MOUNTED VOLUME CONTROL, 48" AFF.

SPEAKER OUTPUT

SPEAKER INPUT

INTERCOM MASTER STATION

INTERCOM REMOTE STATION

GFGI IP ADDRESSABLE CCTV CAMERA LOCATION (PLAN)

CIRCLE INDICATES CEILING MOUNTED

NO CIRCLE INDICATES WALL MOUNTED

CAM

LIGHTING PLAN SYMBOLS MISCELLANEOUS ELECTRICAL SYMBOLS

KEYNOTES

EQUIPMENT CONNECTION, REFER TO APPROPRIATE

SCHEDULE FOR ADDITIONAL INFORMATION.

TELECOMMUNICATIONS SYMBOLS

A, AMP ACCP

AF

AFG

AFF

AIC

ASYM

AT

ATS

AWG

AMPERE

ALARM CENTER CONTROL PANEL

AMPS FRAME

ABOVE FINISH GRADE

ABOVE FINISH FLOOR

AMPS INTERRUPTING CAPACITY

AMPS ASYMMETRICAL

AMPS TRIP

AUTOMATIC TRANSFER SWITCH

AMERICAN WIRE GAGE

BLDG

BP/IS

BUILDING

BYPASS/ISOLATION

HPF HIGH POWER FACTOR

C

CONDUIT

COMMUNITY ANTENNA TELEVISION

CIRCUIT BREAKER

CIRCUIT

CEILING

CENTER LINE

COMMUNICATION

CONTINUOUS

COPPER

C dB dBA DIM

DISC

DWG

DECIBEL

DECIBEL, A-WEIGHTED

DIMENSION

DISCONNECT

DRAWING

E

ELEC

EMCS

EMT

ENCL

EPO EQ

EQUIP

EXIST EXP

EXT

EAST

ELECTRICAL OR ELECTRIC

ENERGY MANAGEMENT CONTROL SYSTEM

ELECTRICAL METALLIC TUBING

ENCLOSURE

EMERGENCY POWER OFF

EQUAL

EQUIPMENT

EXISTING

EXPOSED

EXTERIOR

FACP

FAEP FE

FIRE ALARM CONTROL PANEL FIRE ALARM

EXTENDER PANEL

FURNISHED WITH EQUIPMENT

GFGI

GFI

G, GND, GRD

GOVERNMENT FURNISHED, GOVERNMENT INSTALLED

GROUND FAULT INTERRUPTER

GROUND

GOVERNMENT

IMC

IG

INTERMEDIATE METAL CONDUIT

ISOLATED GROUND

J-BOX JUNCTION BOX

KAIC KV

KVA KW

KWH

KILOAMPS INTERRUPTING CAPACITY (SYM RMS)

KILOVOLTS

KILOVOLT AMPERES

KILOWATT

KILOWATT HOURS

MIN MINIMUM

N

NEC

N, NEUT

N.O.

N C N.C.

NL

NSMR

NORTH

NATIONAL ELECTRICAL CODE

NEUTRAL

NORMALLY OPEN

NO CONNECTION

NORMALLY CLOSED

NIGHT LIGHT

NON-STRUCTURAL METAL ROOF

PA

PNL

PH

PVC

PUBLIC ADDRESS

PANEL

PHASE

POLYVINYL CHLORIDE

RECP REF

REQD

RGS

RECEPTACLE

REFERENCE

REQUIRED

RIGID GALVANIZED STEEL

S

SEC SPEC

SPD SPKR

SSMR ST

STO

SYM

SOUTH

SECONDARY

SPECIFICATIONS

SURGE PROTECTIVE DEVICE

SPEAKER

STANDING SEAM METAL ROOF

SHUNT TRIP

SWITCH-WITH THERMAL OVERLOAD

SYMMETRICAL

TEL TMGB

TYP

TELEPHONE

TELEPHONE MASTER GROUND BUS

TYPICAL

UG

UNO

UNDERGROUND

UNLESS NOTED OTHERWISE

V

VA

VFD

VT

VOLT

VOLT AMPERE

VARIABLE FREQUENCY DRIVE

VOLTAGE TRANSFORMER

W W/

W/O WP

WEST

WITH

WITHOUT

WEATHERPROOF

XFMR TRANSFORMER

208/120 208Y/120V SYSTEM

480/277 480Y/277V SYSTEM

ELECTRICAL ABBREVIATIONS

SECURITY / ACCESS SYMBOLS

POWER PLAN SYMBOLS

CPX CONTROL ACCESS WALL PANEL

'X' DENOTES NUMBER

BMS BALANCE MAGNETIC SWITCH

ML MAGNETIC LOCK

ADA ADA DOOR CONTROL MODULE

DCM DOOR CONTROL MONITOR MODULE

LOW VOLTAGE SWITCH - LOW VOLTAGE CONTROL SYSTEM -

'X' INDICATES CONTROL CIRCUIT.

LV X

PHOTCELL SENSORP

BUS DUCT OR CABLE TRAY RISER (PLAN VIEW)

ENCLOSED CIRCUIT BREAKERCB

L

CATV

CB

CKT

COMM

CONT

Cu

CL

GOVT

OCCUPANCY WALL SENSOR0

MAN HOLE - (EXTERIOR) - SIZED PER PLANS AND NEC.MH

HAND HOLE - (EXTERIOR) - SIZED PER PLANS AND NEC.HH

ELLIPTICAL BUBBLE INDICATES PANELBOARD. ALL RECEPTACLE

AND LIGHTING BRANCH CIRCUITS IN ROOM SHALL BE CIRCUITED

TO THIS PANELBOARD. CIRCUIT NUMBER SHALL BE NEXT TO

POWER OR LIGHTING DEVICE. ALL CONDUITS SHALL CONTAIN A

GREEN INSULATED GROUND WIRE SIZED IN ACCORDANCE WITH

NEC TABLE 250.122, UNLAESS OTHEWISE NOTED.

PP21

ELLIPTICAL BUBBLE INDICATES PANELBOARD. ALL RECEPTACLE

AND LIGHTING BRANCH CIRCUITS IN ROOM SHALL BE CIRCUITED

TO THIS PANELBOARD. ALL CONDUITS SHALL CONTAIN A GREEN

INSULATED GROUND WIRE SIZED IN ACCORDANCE WITH NEC

TABLE 250.122, UNLAESS OTHEWISE NOTED.

PP21-1,3,5

OR

PT POWER TRANFER DEVICE

SR STRIKE RELEASE

CR CARD READER

KP KEY PAD

REX REQUEST TO EXIT DEVICE

HX-1

A1 a a

TERMINATIONS

DRAW-OUT DEVICE

DISCONNECT SWITCH, FUSED

CURRENT TRANSFORMER

POTENTIAL TRANSFORMER

WEATHERHEAD

1 SHORT CIRCUIT CURRENT NODE

COMBINATION VARIABLE FREQUENCY

DRIVE/DISCONNECT

ENCLOSED CIRCUIT BREAKER

DISCONNECT SWITCH

LOAD BREAK

NO LOAD BREAKNLB

ANSI PROTECTIVE DEVICE

A

AMMETER

VOLTMETER

FEEDER REFERENCE

TRANSFER SWITCH

GROUND FAULT PROTECTION

ENGINE GENERATOR

DIGITAL METER

PANELBOARD

SURGE PROTECTION DEVICE

UTILITY PAD MOUNTED TRANSFORMER

MOTOR STARTER

COMBINATION STARTER/DISCONNECT

AUTOMATIC

MANUAL

GENERATOR MONITORING PANEL

GFI

IG

T

SIMPLEX RECEPTACLE

DUPLEX RECEPTACLE

GROUND FAULT INTERRUPTER

ISOLATED GROUND

TAMPER RESISTANT

DOUBLE DUPLEX RECEPTACLE (ESSENTIAL POWER)

SPECIAL RECEPTACLE: WALL, FLOOR, CEILING

DOUBLE DUPLEX RECEPTACLE, FLOOR MOUNTED

DUPLEX RECEPTACLE, FLOOR MOUNTED (ESSENTIAL POWER)

DUPLEX RECEPTACLE, CEILING MOUNTED (ESSENTIAL POWER)

DOUBLE DUPLEX RECEPTACLE, CEILING MOUNTED

DUPLEX RECEPTACLE, ESSENTIAL POWER

(ESSENTIAL POWER)

(ESSENTIAL POWER)

PB

# INDICATES DEVICE SPACING ON-CENTER

M# MULTI-OUTLET ASSEMBLY

JJ

PULLBOX

JUNCTION BOX, WALL OR CEILING MOUNTED OR FLOOR MOUNTEDOR

SEAL-OFF

BUS DUCT

T TRANSFORMER

UTILITY METER

GROUND BAR

CONDUIT CAP

CONDUIT TURNED DOWN OR UP

BUSHED CONDUIT

DISTRIBUTION EQUIPMENT

OR

SPECIAL RECEPTACLE ESSENTIAL POWER: WALL, FLOOR, CEILING

MD MOTION DETECTOR

LR LATCH RELEASE

DB DURESS BUTTON

COMBINATION TELEPHONE/DATA OUTLET, FLOOR MOUNTED

C CLOCK OUTLET

COMMUNICATION/POWER POLE, DEVICES AS INDICATED

ELECTRICAL LEGEND

GENERAL

M

NORMAL EMERGENCY

SHUNT TRIP

WALL MOUNTED LUMINAIRE

SURFACE MOUNTED OR SUSPENDED INDUSTRIAL FLUORESCENT

FIXTURE-NO LENS

RECESSED FLUORESCENT TROFFER FIXTURE

SURFACE MOUNTED FLUORESCENT TROFFER FIXTURE

WALL (SURFACE) MOUNTED FLUORESCENT LIGHT FIXTURE W/LENS

TRACK LIGHTING

COVE LIGHT/UNDERCOUNTER LUMINAIRE

LINEAR PENDANT LUMINAIRE

EMERGENCY BATTERY PACK UNIT

POLE MOUNTED LUMINAIRE

FLOOD LIGHT

CEILING MOUNTED EXIT LIGHT

WALL MOUNTED EXIT LIGHT

UPPER CASE DESIGNATES LUMINAIRE TYPE

LOWER CASE INDICATES SWITCH LEG

EFX

THREE SPEED, FOUR POSITION FAN CONTROL

SWITCH RATED FOR NO. OF FANS INDICATED

ADA DOOR OPERATOR PUSHBUTTON

ADA

X

POWER SWITCH - 'X' DENOTES SPECIFIC FUNCTION

K = KEYED SWITCH

P = PILOT LIGHT

T = TIMER SWITCH

F = FAN CONTROL SWITCH

CB = CIRCUIT BREAKER TYPE

FX

THREE BUTTOM DOOR OPERATOR CONTROL

ON / OFF / AUTO

D

TELEPHONE OUTLET, MOUNTED IN RECESSED FLOOR BOX

XXXX

SPD

GFP

GMP

K

3A

SA

15kV

M

A

V

DM

T

ATS

MTS

E

M

VFD

ST

FUSED DISCONNECT SWITCHF

CB

LB

30A

2P

350 AT

400 AF

48" A.F.F.

3 NUMBER INDICATES CIRCUIT DESIGNATION

D E

S C

R

IP

T

IO

N M

A R

K D

A T

E A

P P

R

D E

S

IG

N E

D B

Y

D W

N B

Y

S U

B M

IT

T

E D

B Y

F

IL

E N

A M

E

S

IZ

E

P L

O T

S C

A L

E

P L

O T

D A

T E

F

IL

E

N U

M B

E R

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

D A

T E

D E

S C

R

IP

T

IO

N M

A R

K D

A T

E A

P P

R

SHEET

IDENTIFICATION

C K

D B

Y

A N

S I

D

A S

N O

T E

D

ME

O MC

S

P A C

N D

A

D

2 3

C

B D A

V

ID

A

L U

K E

P

.E

A

IR

F O

R C

E S

P A

C E

C O

M M

A N

D S

C H

R

IE

V E

R A

IR

F

O R

C E

B A

S E

C O

L O

R A

D O

R E

P A

IR

B

Y R

E P

L A

C E

H V

A C

S Y

S T

E M

B

S C

H R

IE

V

E R

A

IR

F O

R B

A S

E C

O L

O R

A D

O

G L

E N

-1

/2

/2

:5

:2

A

M

E-001

S W

IL

L

IA

M S

S W

IL

L

IA

M S

K B

IN

K

L E

Y

E L E

C T

R

IC

A L L

E G

E N

D A

N D

A B

B R

E V

IA

T

IO

N

S

100% ISSUED FOR CONSTRUCTION

O

C T

P

F A

-1

-D

-0

-1

E

-0

.D

W G

EXISTING

MCC1

EXISTING 400A/3P

NON-FUSED DISC. SW.

EXISTING 400A/3P

NON-FUSED DISC. SW.

(E) CU-1(E) CU-2

(E) C-1

(E) C-2

EXISTING CHILLER

CONTROL PANEL

EXISTING CHILLER

CONTROL PANEL

EXISTING

PULL BOX

EXISTING

60A/3P

DISC. SW.

EXISTING

60A/3P

DISC. SW.

EXISTING

EMI FILTER TUNNEL

MECHANICAL VAULT

MECHANICAL

MENS

WOMENS

KITCHEN

CORRIDOR

GENERATOR

EXISTING 60A/3P

DISC. SW.

6 6

D E

S C

R

IP

T

IO

N M

A R

K D

A T

E A

P P

R

D E

S

IG

N E

D B

Y

D W

N B

Y

S U

B M

IT

T

E D

B Y

F

IL

E N

A M

E

S

IZ

E

P L

O T

S C

A L

E

P L

O T

D A

T E

F

IL

E

N U

M B

E R

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

D A

T E

D E

S C

R

IP

T

IO

N M

A R

K D

A T

E A

P P

R

SHEET

IDENTIFICATION

C K

D B

Y

A N

S I

D

A S

N O

T E

D

ME

O MC

S

P A C

N D

A

D

2 3

C

B D A

V

ID

A

L U

K E

P

.E

A

IR

F O

R C

E S

P A

C E

C O

M M

A N

D S

C H

R

IE

V E

R A

IR

F

O R

C E

B A

S E

C O

L O

R A

D O

R E

P A

IR

B

Y R

E P

L A

C E

H V

A C

S Y

S T

E M

B

S C

H R

IE

V

E R

A

IR

F O

R B

A S

E C

O L

O R

A D

O

G L

E N

-1

/2

/2

:5

:2

A

M

ED101

S W

IL

L

IA

M S

S W

IL

L

IA

M S

K B

IN

K

L E

Y

E L E

C T

R

IC

A L D

E M

O L

IT

IO

N

P L A

N

100% ISSUED FOR CONSTRUCTION

O

C T

P

F A

-1

-D

-0

-1

E

D

.D

W G

SCALE: 1/8" = 1'-0"

ELECTRICAL DEMOLITION PLAN

N

04 8 16268

SCALE: 1/8"=1'-0"

SHEET NOTES:

1.

2.

3.

4.

5.

ELECTRICAL DRAWINGS ILLUSTRATE ELECTRICAL

EQUIPMENT AND DESIGN REQUIREMENTS, REFER TO

MECHANICAL DRAWINGS FOR COORDINATION.

REFER TO SABER SPECIFICATIONS FOR ADDITIONAL

REQUIREMENTS.

IF CONFLICTS SHOULD OCCUR DURING CONSTRUCTION

BETWEEN DRAWINGS AND SPECIFICATIONS THE MORE

RESTRICTIVE REQUIREMENT SHALL TAKE PRECEDENCE.

CONTRACTOR SHALL PROVIDE THE NECESSARY

PROTECTION FOR EXISTING LIGHT FIXTURES AND

ELECTRICAL EQUIPMENT TO PREVENT DAMAGE.

CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIR OR

REPLACEMENT OF ANY EQUIPMENT DAMAGED DURING THIS

PROJECT.

REFER TO E-101 FOR NEW WORK FOR THIS AREA.

KEYNOTES:

EXISTING DISCONNECT SWITCH SHALL BE REMOVED.

EXISTING ELECTRICAL EQUIPMENT SHALL REMAIN.

DISCONNECT AND REMOVE EXISTING CONDUIT FROM

DISCONNECT SWITCH BACK TO PENETRATION OF CONDUIT

THROUGH UTILITY PAD. LEAVE ENOUGH CONDUIT FOR

EXTENSION TO NEW CONDENSING UNIT CONNECTION,

REFER TO E-101.

EXISTING CONDUIT AND WIRE SHALL BE DISCONNECTED

AND REMOVED. REFER TO E-101 FOR NEW FEEDER

SCHEDULE.

EXISTING CHILLER CONTROL PANEL SHALL BE

DISCONNECTED AND REMOVED.

EXISTING UNDERGROUND CONDUIT SHALL REMAIN.

EXISTING CONDUIT SHALL REMAIN AND BE RE-USED FOR

NEW BRANCH CIRCUIT CONDUCTORS. DICONNECT AND

REMOVE EXISTING CONDUCTORS. REFER TO E-101 FOR

NEW FEEDER SCHEDULE.

(E) PP-1

EXISTING

MCC1

NEW 400A/3P

NON-FUSED

DISC. SW.

NEW 400A/3P

NON-FUSED

DISC. SW.

NEW CHILLER

CONTROL PANEL

NEW CHILLER

CONTROL PANEL

EXISTING

PULL BOX

CU-1CU-2

CH-1

CH-2

NEW 60A/3P

DISC. SW.

NEW 60A/3P

DISC. SW.

NEW 60A/3P

DISC. SW.

MECHANICAL VAULT

GENERATOR

MECHANICAL

MENS

WOMENS

KITCHEN

TUNNEL

CORRIDOR

2 2

2 2

5 5

WP

GFI

10 10

M WH

MCC-1 480V, 3PH

400AT

600AF

35A

60A 3-P

35A

60A 3-P

EMI

AIR

COOLED

COND. #1

SUPPLY SUPPLY

3-P 30A

20A

3-P 30A

20A

3-P 200A

FAN #1 FAN #2

3-P 400A

300A 300A

3-P 400A

3-P 30A

20A

RELAY

PANEL

SECTION 3 OF 6 SECTION 4 OF 6

HEATER

BACKUP

WATER

100A 3-P

90A

SECTION 5 OF 6 SECTION 6 OF 6

BUS-A

MAIN

NO 1

BUS-B

CH-1

CU-1

EXHAUST

FAN #1

BLANK

SPACE

BOILERCHILLER #1

PULL

BOX

BLANK

SPACE

B

MAIN

NO 1 400AT

600AF

AIR

COOLED

COND. #2

CU-2

EMI

PULL

BOX

M M

CH-2

CHILLER #2

PULL

BOX

PULL

BOX

NOTE:

HEAVIER LINE WEIGHT INDICATES NEW

WORK/EQUIPMENT. LIGHTER LINE WEIGHT

INDICATES EXISTING EQUIPMENT

60A 3-P

60A 3-P

60A 3-P

400A 3-P

400A 3-P

3 3

3 3

J

60A 3-P

J

5 5

NEW #250kcmil + #4 GND

FEEDER CONDUIT

NEW 2 1/2"C

NEW 3#8 + #10 GND EXISTING 1"C

3 NEW 8#14 + #14 GND EXISTING 3/4"C

4 NEW 4#14 + #14 GND NEW 3/4"C

5 NEW 3#8 + #10 GND NEW 3/4"C

FEEDER SCHEDULE

CH-1

CH-2

CHILLER

DESCRIPTION VOLTAGE

480V

CHILLER 480V

CU-1

AIR COOLED

CONDENSING UNIT

CU-2

ITEM PH MCA FLA DISC STARTER CKT. BRKR./FUSE WIRE SIZE CONDUIT PANEL CKT. # NOTES

480V

480V

400A/3P

NEMA 1

SUPPLIED

W/ UNIT

33.8

300A FUSE

REFER TO FEEDER

SCHEDULE

MCC1

SUPPLIED

W/ UNIT

227 300A FUSE MCC1

60A/3P

NEMA 3R

EXISTING 35A FUSE MCC1

33.8 EXISTING 35A FUSE MCC1

MECHANICAL EQUIPMENT SCHEDULE

REFER TO FEEDER

SCHEDULE

REFER TO FEEDER

SCHEDULE

REFER TO FEEDER

SCHEDULE

REFER TO FEEDER

SCHEDULE

REFER TO FEEDER

SCHEDULE

REFER TO FEEDER

SCHEDULE

REFER TO FEEDER

SCHEDULE

AIR COOLED

CONDENSING UNIT

400A/3P

NEMA 1

60A/3P

NEMA 3R

D E

S C

R

IP

T

IO

N M

A R

K D

A T

E A

P P

R

D E

S

IG

N E

D B

Y

D W

N B

Y

S U

B M

IT

T

E D

B Y

F

IL

E N

A M

E

S

IZ

E

P L

O T

S C

A L

E

P L

O T

D A

T E

F

IL

E

N U

M B

E R

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

D A

T E

D E

S C

R

IP

T

IO

N M

A R

K D

A T

E A

P P

R

SHEET

IDENTIFICATION

C K

D B

Y

A N

S I

D

A S

N O

T E

D

ME

O MC

S

P A C

N D

A

D

2 3

C

B D A

V

ID

A

L U

K E

P

.E

A

IR

F O

R C

E S

P A

C E

C O

M M

A N

D S

C H

R

IE

V E

R A

IR

F

O R

C E

B A

S E

C O

L O

R A

D O

R E

P A

IR

B

Y R

E P

L A

C E

H V

A C

S Y

S T

E M

B

S C

H R

IE

V

E R

A

IR

F O

R B

A S

E C

O L

O R

A D

O

G L

E N

-1

/2

/2

:5

:2

A

M

E-101

S W

IL

L

IA

M S

S W

IL

L

IA

M S

K B

IN

K

L E

Y

E L E

C T

R

IC

A L P

O W

E R

S Y

S T

E M

F L O

O R

P L A

N

100% ISSUED FOR CONSTRUCTION

O

C T

P

F A

-1

-D

-0

-1

E

-1

.D

W G

SCALE: 1/8" = 1'-0"

ELECTRICAL POWER SYSTEM FLOOR PLAN

SHEET NOTES:

1.

2.

3.

4.

ELECTRICAL DRAWINGS ILLUSTRATE ELECTRICAL

EQUIPMENT AND DESIGN REQUIREMENTS, REFER TO

MECHANICAL DRAWINGS FOR COORDINATION.

REFER TO SABER SPECIFICATIONS FOR ADDITIONAL

REQUIREMENTS.

IF CONFLICTS SHOULD OCCUR DURING CONSTRUCTION

BETWEEN DRAWINGS AND SPECIFICATIONS THE MORE

RESTRICTIVE REQUIREMENT SHALL TAKE PRECEDENCE.

CONTRACTOR SHALL PROVIDE THE NECESSARY

PROTECTION FOR EXISTING LIGHT FIXTURES AND

ELECTRICAL EQUIPMENT TO PREVENT DAMAGE.

CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIR OR

REPLACEMENT OF ANY EQUIPMENT DAMAGED DURING THIS

PROJECT.

KEYNOTES:

PROVIDE NEW NEMA 1 DISCONNECT SWITCH.

PROVIDE NEW NEMA 3R DISCONNECT SWITCH.

REPLACE EXISTING FUSES WITH FUSES INDICATED.

PROVIDE NEW NEMA 3R JUNCTION BOX FOR EXTENSION OF

BRANCH CIRCUIT TO NEW DISCONNECT SWITCH.

PROVIDE 120V, 20A, EMI FILTER, NEMA 1, FRONT COVER

ACCESS, DUAL COVER DESIGN, CORCOM CDEUW SERIES OR

EQUAL. REFER TO HEMP PENETRATION DETAIL 1/M201 FOR

PENETRATION OF HEMP BOUNDARY. COORDINATE EXACT

LOCATION IN FIELD.

PROVIDE (2#12 + #12G)3/4"C FROM SPARE 20A/1P CIRCUIT #22

IN EXISTING PANEL "PP-1".

FIELD COORDINATE EXACT ROUTING OF CONDUIT. ROUTE

CONDUIT HIGH ON EXTERIOR WALL, JUST UNDER GUTTER.

PAINT CONDUIT TO MATCH EXISTING WALL.

EXISTING EMI FILTER TO REMAIN UNALTERED. REPLACE RF

GASKETING IF REQUIRED. REPAIR OR RETHREAD MISSING OR

DAMAGED COVER BOLTS PER FILTER MANUFACTURER'S

RECOMMENDATION.

RF TEST HEMP SHIELDING PRIOR TO STARTING OF WORK FOR

BASELINE PERFORMANCE. ALERT CONTRACTING OFFICE IF

TEST DOES NOT MEET MIL-STD 188-125-1. RE-TEST HEMP

SHIELDING IAW MIL-STD 188-125-1 AFTER WORK IS COMPLETE.

CORRECT DEFICIENCIES TO MEET MIL-STD 188-125-1.

CONTRACTOR SHALL VERIFY IF 120V CIRCUIT IS REQUIRED AT

CONDENSING UNIT FOR CONTROLS. IF REQUIRED

CONTRACTOR SHALL EXTEND UNDERGROUND THE NEW 120V

CIRCUIT AT THE EXTERIOR DUPLEX RECEPTACLE TO THE

CONTROL LOCATION ON THE CONDENSING UNIT.

N

04 8 16268

SCALE: 1/8"=1'-0"

SCALE: N.T.S.

PARTIAL MCC1 ONE-LINE DIAGRAM

TEMPORARY POWER

THE CONTRACTOR SHALL PROVIDE A PORTABLE DIESEL

POWERED GENERATOR TO PROVIDE TEMPORARY POWER

FOR A TEMPORARY CHILLER WHILE THE EXISTING CHILLERS

ARE BEING REPLACED. COORDINATE THE EXACT VOLTAGE

AND KVA/KW RATING WITH THE TEMPORARY CHILLER

PROVIDED.

Sheets
DM101 - MECHANICAL DEMOLITION PLAN, ABBREVIATIONS AND LEGEND
G-100 - COVER SHEET AND DRAWING INDEX
M-101 - MECHANICAL FLOOR PLAN, ABBREVIATIONS, AND LEGEND
M-201 - MECHANICAL SCHEDULES
19-1001_DM101.pdf
Sheets
DM101 - MECHANICAL DEMOLITION PLAN, ABBREVIATIONS AND LEGEND
G-100 - COVER SHEET AND DRAWING INDEX
M-101 - MECHANICAL FLOOR PLAN, ABBREVIATIONS, AND LEGEND
M-201 - MECHANICAL SCHEDULES
19-1001_M-101.pdf
Sheets
DM101 - MECHANICAL DEMOLITION PLAN, ABBREVIATIONS AND LEGEND
G-100 - COVER SHEET AND DRAWING INDEX
M-101 - MECHANICAL FLOOR PLAN, ABBREVIATIONS, AND LEGEND
M-201 - MECHANICAL SCHEDULES
19-1001_M-201.pdf
Sheets
DM101 - MECHANICAL DEMOLITION PLAN, ABBREVIATIONS AND LEGEND
G-100 - COVER SHEET AND DRAWING INDEX
M-101 - MECHANICAL FLOOR PLAN, ABBREVIATIONS, AND LEGEND
M-201 - MECHANICAL SCHEDULES

File details come from the government source that posted it. Updated .