A13_SXHT 12-1092 Environmental Sampling Report.pdf

PDF 500 KB Posted

Attached to
SXHT 12-1092 Repair Emergency Power SFS B1319
Solicitation number
FA252125B0004
Issued by

About this file

This document is an Environmental Sampling Report prepared by Sunrise Systems of Brevard, Inc. for a project at Patrick Space Force Station, specifically focusing on Building 1319's Emergency Power Repair. The report details environmental testing conducted on the interior coating of Room 104's CMU wall and the transformer pad, which included RCRA-8 metals and PCB testing, as well as asbestos sampling.

Key findings from the laboratory analysis include the presence of extremely low levels of Barium in the wall coating, with no PCBs or asbestos detected in the samples. The report emphasizes that any disturbance of the coatings must comply with OSHA regulations regarding Permissible Exposure Limits, including appropriate worker training and personal protective equipment. The samples were analyzed by Schneider Laboratories in Virginia, with the testing completed on December 20-21, 2023, as part of the environmental assessment for the facility's upcoming emergency power repair project.

View the file

Other files

Show all 20

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sunrise Systems of Brevard, Inc.

Environmental Contractor: Asbestos, Lead, & Mold

PO Box 3188 / Cocoa, FL 32924-3188 (321) 636-1618/ fax (321) 639-7397

CB-C025111 ZA-0000064 CJ-C046240

Environmental Sampling Report

SXHT 12-1092

Repair Emergency Power F1319 Patrick Space Force Station, FL

Prepared By

Sunrise systems of Brevard, Inc PO Box 3188

Cocoa FL

Sunrise Systems of Brevard, Inc.

Environmental Contractor: Asbestos, Lead, & Mold

PO Box 3188 / Cocoa, FL 32924-3188 (321) 636-1618/ fax (321) 639-7397

CB-C025111 ZA-0000064 CJ-C046240

Sunrise Systems of Brevard, Inc was contracted by Rhodes + Brito Architects to perform environmental sampling of the interior coating in Rm 104 and the Transformer pad at Bldg 1319 at Patrick Space Force Station, FL

The scope of this sampling included RCRA-8 metals and PCB testing of the interior coating on the CMU wall in Rm 104, and asbestos samples of the CMU wall and transformer pad. This is not a full building survey, but a targeted sampling of material identified to us by Rhodes and Brito.

RCRA-8 Metals

The sample was sent to Schneider Labs in Virginia for analysis. The coatings were sampled for total metals.

Total Metals analysis showed the presence of Barium in the coating of the CMU wall in Rm

104. Levels were extremely low (see attached results). As OSHA requires worker protection from exposure regardless of levels in the coating should disturbance occur, disturbance of the coatings must be done in accordance with OSHA regulations regarding Permissible Exposure Limits, and any other applicable federal, state, or local rules and regulations. “Disturbance” is considered to be cutting (with a rotating blade), grinding, sanding or abrading the material in question. Workers must have the appropriate training and wear appropriate ppe.

PCBs

Samples of the coatings on the wall were sent to Schneider Labs in Virginia for analysis. The coatings were sampled for PCB content. No PCBs were detected in the coatings.

ASBESTOS

Samples were taken from the exterior slab and CMU wall. Samples were sent to Schneider Labs in Virginia for analysis. No asbestos was detected in any of the sampled material.

In addition, no other items were readily identifiable as potentially asbestos-containing material inside the facility.

All sample results are attached at the end of this narrative.

Respectfully, Robert Crowe Sunrise systems of Brevard, Inc.

Attn:

Address: 280 North Burnett Road Order #: 544231

Cocoa, FL 32924-3188

Project: Bldg 1319 Env Sampling

23000

Sunrise Systems of Brevard, Inc (4020)Customer:

23000bcNumber: PO Number:

Received 12/20/23

Schneider Laboratories Global, Inc 2512 W. Cary Street • Richmond, Virginia • 23220-5117 804-353-6778 • 800-785-LABS (5227) • Fax 804-359-1475

Location: CCSFS

12/21/23Reported

Analysis Report

Cust. Sample ID

Parameter

Sample ID Location

UnitsRL* AnalystAnalysis DateResultMethod

Matrix Bulk, Paint

544231-001 1 Room 104 Wall Coating

Semi-volatile Organic Compounds

Aroclor - 1016 PPB AE12/20/23477<478SW846 8082A

Aroclor - 1221 PPB AE12/20/23477<478SW846 8082A

Aroclor - 1232 PPB AE12/20/23477<478SW846 8082A

Aroclor - 1242 PPB AE12/20/23477<478SW846 8082A

Aroclor - 1248 PPB AE12/20/23477<478SW846 8082A

Aroclor - 1254 PPB AE12/20/23477<478SW846 8082A

Aroclor - 1260 PPB AE12/20/23477<478SW846 8082A

Aroclor - 1262 PPB AE12/20/23477<478SW846 8082A

Aroclor - 1268 PPB AE12/20/23477<478SW846 8082A

544231-002 1 Room 104 Wall Coating

Metals Analysis

Arsenic PPM DM12/21/236.02<6.03EPA 6010D

Barium PPM DM12/21/236.02112EPA 6010D

Cadmium PPM DM12/21/236.02<6.03EPA 6010D

Chromium PPM DM12/21/2315.1<15.1EPA 6010D

Lead PPM DM12/21/236.02<6.03EPA 6010D

Mercury PPM SA12/21/230.108<0.108EPA 7471B

Selenium PPM DM12/21/236.02<6.03EPA 6010D

Silver PPM DM12/21/236.02<6.03EPA 6010D

544231-12/21/23 04:42 PM

Manager

Reviewed By: Kelly Muncy

Surrogate Recoveries

544231-001 - PCB

MIDCB

90%TCMX

All internal QC parameters were met. Unusual sample conditions, if any, are described. Surrogate Spike results designated with "D" indicate that the analyte was diluted out. "MI" indicates matrix interference. Concentration and *Reporting Limit (RL) based on areas provided by client. Values are reported to three significant figures. Solid PPM = mg/kg | PPB = µg/kg and Water PPM = mg/L | PPB = µg/L. The test results apply to the sample as received.

Attn:

Address: 280 North Burnett Road Order #: 544231

Cocoa, FL 32924-3188

Project: Bldg 1319 Env Sampling

23000

Sunrise Systems of Brevard, Inc (4020)Customer:

23000bcNumber: PO Number:

Received 12/20/23

Schneider Laboratories Global, Inc 2512 W. Cary Street • Richmond, Virginia • 23220-5117 804-353-6778 • 800-785-LABS (5227) • Fax 804-359-1475

Location: CCSFS

12/21/23Reported

Analysis Report

Cust. Sample ID

Parameter

Sample ID Location

UnitsRL* AnalystAnalysis DateResultMethod

Matrix Bulk, Paint

Method Parameter Florida Virginia

State Certifications

Arsenic ELAP Certified VELAP CertifiedEPA 6010D

Barium ELAP Certified VELAP CertifiedEPA 6010D

Cadmium ELAP Certified VELAP CertifiedEPA 6010D

Chromium ELAP Certified VELAP CertifiedEPA 6010D

Lead ELAP Certified VELAP CertifiedEPA 6010D

Selenium ELAP Certified VELAP CertifiedEPA 6010D

Silver ELAP Certified VELAP CertifiedEPA 6010D

Mercury ELAP Certified VELAP CertifiedEPA 7471B

Aroclor - 1016 Not Certified VELAP CertifiedSW846 8082A

Aroclor - 1221 Not Certified VELAP CertifiedSW846 8082A

Aroclor - 1232 Not Certified VELAP CertifiedSW846 8082A

Aroclor - 1242 Not Certified VELAP CertifiedSW846 8082A

Aroclor - 1248 Not Certified VELAP CertifiedSW846 8082A

Aroclor - 1254 Not Certified VELAP CertifiedSW846 8082A

Aroclor - 1260 Not Certified VELAP CertifiedSW846 8082A

Aroclor - 1262 Not Certified VELAP CertifiedSW846 8082A

Aroclor - 1268 Not Certified VELAP CertifiedSW846 8082A

State Certificate Number

Florida ELAP E87828

Virginia VELAP 12664

All internal QC parameters were met. Unusual sample conditions, if any, are described. Surrogate Spike results designated with "D" indicate that the analyte was diluted out. "MI" indicates matrix interference. Concentration and *Reporting Limit (RL) based on areas provided by client. Values are reported to three significant figures. Solid PPM = mg/kg | PPB = µg/kg and Water PPM = mg/L | PPB = µg/L. The test results apply to the sample as received.

File details come from the government source that posted it. Updated .