IR CENTAC 2 M79-1658 23 DEC 80.pdf

PDF 11 MB Posted

Attached to
RQOO CENTAC 1 Overhaul Federal contract opportunity
Solicitation number
FA239625RB006
Issued by
Department of the Air Force Materiel Command Research Laboratory

About this file

This document is a detailed test performance report for a 4C150M4B2 - 735.9 PSIG component, conducted on December 22, 1980, at Wright Patterson Air Force Base. The test involves a five-point performance analysis of a G.E. 5000HP 4160V motor with a Westinghouse booster, focusing on comprehensive mechanical and thermal measurements across multiple stages.

The report includes extensive data on various parameters such as intake temperature, relative humidity, bar pressure, nozzle temperatures, air density, flow rates, and component-specific metrics like stage seal air pressures, oil temperatures, and vibration readings. Key measurements were taken across six stages, including detailed recordings of temperature, pressure, and performance characteristics for each stage's plain and thrust components, as well as bullgear and motor performance. The documentation provides a granular technical assessment of the equipment's operational characteristics under test conditions, likely for quality assurance, maintenance, or performance validation purposes.

View the file

Other files for this federal contract opportunity

Other files attached to RQOO CENTAC 1 Overhaul, newest first.
File Type Posted
CENTAC1 QnAs.pdf PDF
Centac Specification and Performance Data.pdf PDF
Drawings (1-7).pdf PDF
IR CENTAC 1 M79-1657 18 DEC 80.pdf PDF
Drawings (8-11).pdf PDF
Drawings (12-34).pdf PDF
Drawings (35-44).pdf PDF
IR Centac Shop Test M79-1658-1668.pdf PDF
Centac_1_Stage4_5_Piping_1.JPG JPG image
Centac_1_4C_Section_1.JPG JPG image
Centac_1_4C_Section_5.JPG JPG image
Centac_1_Stage4_5_Piping_4.JPG JPG image
Centac_2_Stage4_5_Piping_4.JPG JPG image
Centac_2_Stage4_5_Piping_3.JPG JPG image
Centac_1_4C_Section_4.JPG JPG image
Sign in Sheet.pdf PDF
Centac_1_Stage4_5_Piping_2.JPG JPG image
Centac_1_4C_Section_Nameplate.JPG JPG image
Centac_1_Stage4_5_Piping_3.JPG JPG image
Centac_2_Stage4_5_Piping_1.JPG JPG image
Centac_1_4C_Section_6.JPG JPG image
Centac_1_4C_Section_2.JPG JPG image
Centac_1_4C_Section_3.JPG JPG image
Solicitation - FA239625RB006.pdf PDF
Past Performance Questionaire.pdf PDF
Attach. 1 - SOW - CENTAC 1 Overhaul - 19 Nov 24.pdf PDF
Attach. 3 - Base Acces & Map - 14 Apr 25.pdf PDF
Past Performance Reference List.pdf PDF
Attach. 2 - DBA WD - OH20240081 - 14 Mar 25.pdf PDF
Attach. 1 - SOW - CENTAC 1 Overhaul - 19 Nov 24.pdf PDF
Attach. 2 - DBA WD - OH20240081 - 14 Mar 25.pdf PDF
Past Performance Reference List.pdf PDF
Attach. 3 - Base Access Information & Map - 11 Apr 25.pdf PDF
Solicitation - FA239625RB006.pdf PDF
Past Performance Questionaire.pdf PDF
Show all 35

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

File details come from the government source that posted it. Updated .