This document is a detailed test performance report for a 2-stage booster motor (AC150M4) tested at Wright Patterson Air Force Base on December 17-18, 1980. The report contains multiple data pages documenting extensive technical performance measurements including vibration, pressure, bearing oil temperatures, and motor characteristics across different stages and conditions. Key measurements include:
Test specifications include a G.E. 5000HP 4160V motor with Westinghouse 2500HP 238 configuration. The test was a five-point performance evaluation conducted with customer witnesses, with contract engineers from Barber/Kincer/Krieger. The documentation comprehensively tracks parameters such as intake temperatures, upstream and downstream nozzle pressures, air density, flow rates, discharge temperatures, motor input power, and various mechanical performance metrics across multiple test runs and stages of the booster motor.