4-Phase 2 BID PLANS.pdf

PDF 6 MB Posted

Attached to
Thornton Road Low Pressure Sewer - Phase II
Solicitation number
US.196130
Issued by
Delaware County, Chicora Borough, Pennsylvania

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

TH

O

R N

TO

N

R D

GLEN MILLS RD

BUCK RUN

PHASE 2

PROJECT SITE

P:

\P ro jec ts\

TH

RN

TH

OR

NB

UR

Y\

TH

RN

- T

HO

RN

TO

N

RO

AD

S

EW

ER

\D

ES

IG

N\

PE

RM

IT

P

LA

NS

\C S0

- P

ER

M

IT

.d wg

PL

OT

TE

D:

7/

/2

3:

P M, B

Y:

Se da K or km az

ST

YL

E:

Pe nn on i N

CS

.st b

PR

OJ

EC

T

ST

AT

US

CS0001

B Y

N O

D

A

TE

R E

V

IS

IO

N

S

TH

O

R N

TO

N

R O

A D

L O

W P

R E

S S

U R

E S

E W

E R

P

H A

S E

TH

O R

N

TO

N R

O A

D

TH

O R

N B

U R

Y , P

A

TO

W N

S H

IP

D

R

IV

E C

H E

Y N

E Y

, P A

TO

W

N S

H

IP

O F

TH

O

R N

B U

R Y

C O

V E

R S

H E

E T

THRN 0310.02

AS NOTED

SK

6/22/2025

CF

SHEET

APPROVED BY

OF1 6

DRAWN BY

DRAWING SCALE

DATE

PROJECT

ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES

ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE

PROJECT. THEY ARE NOT INTENDED OR REPRESENTED

TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON

THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER

PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION

OR ADAPTATION BY PENNONI ASSOCIATES FOR THE

SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS

SOLE RISK AND WITHOUT LIABILITY OR LEGAL

EXPOSURE TO PENNONI ASSOCIATE; AND OWNER SHALL

INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES

FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES

ARISING OUT OF OR RESULTING THEREFROM.

A

LL

D

IM

E N

S

IO

N S

M U

S T

B E

V E

R

IF

IE

D

B Y

C O

N

TR

A C

TO

R

A N

D O

W N

E R

M U

S T

B E

N O

TI

FI

E D

O F

A N

Y D

IS

C

R E

P A

N C

IE

S

B E

FO

R

E P

R O

C E

E D

IN

G

W

IT

H W

O R

K

TOWNSHIP OF THORNBURY

6 TOWNSHIP DRIVE

CHEYNEY, PA 19319

THORNTON ROAD LOW PRESSURE SEWER - PHASE 2

CONTRACT 2025-03

LOCATION MAP

Scale: 1" = 600'

N O

R

TH

CALL 1-800-242-1776

CALL BEFORE YOU DIG

BEFORE YOU DIG ANYWHERE IN PENNSYLVANIA

PA. ACT 287 OF 1974 REQUIRES THREE WORKING DAYS

NOTICE TO UTILITIES BEFORE YOU EXCAVATE, DRILL OR

BLAST PENNSYLVANIA ONE-CALL SYSTEM, INC.

SERIAL NUMBER(S):

PREPARED BY:

PENNONI ASSOCIATES INC.

3100 Horizon Drive, Suite 200 King of Prussia, PA 19406 T 610.277.2402 F 610.277.7449

PE

N

N O

N I A

SS

O

C

IA

TE

S

IN

C

H or iz on D riv e, S ui te

Ki ng o f P ru ss ia

, P A

T

0.

7.

F

0.

7.

BID PLANS

P:

\P ro jec ts\

TH

RN

TH

OR

NB

UR

Y\

TH

RN

- T

HO

RN

TO

N

RO

AD

S

EW

ER

\D

ES

IG

N\

PE

RM

IT

P

LA

NS

\C S0

- P

ER

M

IT

TE

D:

6/

/2

9:

A M, B

Y:

Se da K or

ST

YL

E:

Pe nn on i N

CS

.st b

PR

OJ

EC

T

ST

AT

US

CS0002

BY

N

O

D

AT

E R

EV

IS

IO

N

S

TH

O

R N

TO

N

R O

AD

TH

O R

N

BU

R Y, P A

TO

W N

SH

IP

D R

IV

E

C H

EY

N

EY

, P

A

TO

W

N

SH

IP

O

F

TH

O R

N

BU

R Y

G

EN

ER

AL

N O

TE

S

AS NOTED

APPROVED BY

DRAWN BY

DRAWING SCALE

DATE

PROJECT

ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES

ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE

PROJECT. THEY ARE NOT INTENDED OR REPRESENTED

TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON

THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER

PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION

OR ADAPTATION BY PENNONI ASSOCIATES FOR THE

SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS

SOLE RISK AND WITHOUT LIABILITY OR LEGAL

EXPOSURE TO PENNONI ASSOCIATE; AND OWNER SHALL

INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES

FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES

ARISING OUT OF OR RESULTING THEREFROM.

AL

L

D

IM

EN

SI

O N

S M

U

ST

B E

VE

R

IF

IE

D B

Y C

O N

TR

AC

TO

R

AN

D

O W

N

ER

M U

ST

B

E N

O

TI

FI

ED

O F

AN

Y

D

IS

C R

EP

AN

C

IE

S

BE

FO

R

E

PR

O C

EE

D

IN

G

W

IT

H W

O R

K

ACT 127 OF 2024

PECO ENERGY PHONE #: 610-725-7160

CHESTER WATER PHONE #: 610-876-8181

VERIZON PENNSYLVANIA INC PHONE #: 302-995-5440

THORNBURY TOWNSHIP PHONE #: 610-399-8383

6 TOWNSHIP DRIVE

MARSHALTON, DE 19808

CHEYNEY, PA 19319

1050 W. SWEDESFORD RD

BERWYN SERVICE BUILDING

415 WELSH ST

CHESTER, PA 19103

1625 NEWPORT GAP PIKE, ROOM 1

ALL DESIGNERS AND CONTRACTORS UTILIZING THIS PLAN AND

THE INFORMATION CONTAINED THEREON ARE CAUTIONED TO

OF 1974, AS AMENDED.

UTILITY LIST:

BERWYN, PA 19132

COMCAST CABLE COMMUNICATIONS PHONE #: 800-266-2278

75 EAST LANCASTER AVENUE

ARDMORE, PA 19003

LIST OF DRAWINGS:

TITLE DRAWING NO. SHEET NO.

COVER SHEET CS0001 1 OF 6

DETAILS CS6001

DETAILS / MAINTENANCE AND PROTECTION CS6002

THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND

STRUCTURES AND UTILITIES, SUCH AS WATER MAINS, SEWERS, TELEPHONE,

GAS AND ELECTRIC CONDUITS, ETC. AND ABOVE GROUND UTILITIES, WHICH

MAY BE ENCOUNTERED DURING CONSTRUCTION OPERATIONS. TEST HOLES

SHALL BE DUG TO DETERMINE THE POSITION OF THE UNDERGROUND

STRUCTURES AND UTILITIES, OR THE CONTRACTOR SHALL ARRANGE WITH THE

OWNERS OF SUCH UNDERGROUND STRUCTURES AND UTILITIES TO ASSIGN A

REPRESENTATIVE TO MARK THE LOCATIONS. THE CONTRACTOR SHALL PAY

THE COST OF DIGGING TEST HOLES AND LIKEWISE HE SHALL PAY THE COST OF

THE SERVICE OF THE REPRESENTATIVES OF THE OWNERS OF SUCH UTILITIES

FOR LOCATING THE SAID UTILITIES. THE COST OF DETERMINING THE

LOCATIONS IS TO BE INCLUDED IN THE PRICES BID. THE LOCATIONS AND DEPTH

OF EXISTING STRUCTURES AND UTILITIES AS SHOWN IN THE CONTRACT

DOCUMENTS IS SIMPLY FOR THE GUIDANCE OF THE CONTRACTOR AND HAVE

NOT BEEN FIELD LOCATED. SINCE THE INFORMATION IS AS FURNISHED BY THE

RESPECTIVE UTILITIES, OR TAKEN FROM NON-AS-BUILT PLANS, THE ENGINEER

IS NOT RESPONSIBLE FOR THE ACCURACY OF THE PLANS IN THIS RESPECT.IT IS

THE CONTRACTOR'S RESPONSIBILITY TO PLACE PERMANENT COLOR CODED

MARKERS OR TRACER WIRE ALONG ALL PRIVATE LATERALS TO INDICATE THE

TYPE AND LOCATION OF ALL LATERALS INSTALLED, IN ACCORDANCE WITH THE

PA 1 CALL, ACT 127 OF 2024. THESE MARKERS ARE INTENDED ASSIST IN

LOCATING EFFORTS OF THE PRIVATE LINE IN THE FUTURE.

PA ACT 287 OF 1974 AS AMENDED BY

SCALE: 1" = 1000'

LOCATION PLAN - THORNTON ROAD

PROJECT

LOCATION

GENERAL NOTES CS0002

COMPLY WITH THE REQUIREMENTS OF PENNSYLVANIA ACT 287

SERIAL NOS: 20243391914 / 20243481059

PLAN AND PROFILE CS1001 3 OF 6

OF TRAFFIC PLAN

APPROXIMATE EXISTING PROPERTY LINE/RIGHT-OF-WAY LINE

EXISTING DOUBLE YELLOW LINE

EXISTING DRAIN LINE

EXISTING PHONE LINE

EXISTING WATER MAIN

EXISTING UTILITY POLE

EXISTING EDGE OF PAVEMENT

EXISTING OVERHEAD ELECTRIC

LEGEND

EXISTING MAJOR CONTOUR

EXISTING MINOR CONTOUR

EXISTING FENCE

EXISTING BRUSH

PROPOSED LOW PRESSURE FORCE MAIN

EXISTING DECIDUOUS TREE

E.O.P D/Y

APPROXIMATE LATERAL LOCATION (11

4" Ø)L L L L L L L

PE

N

N O

N I A

SS

O

C

IA

TE

S

IN

C

H or iz on D riv e, S ui te

Ki ng o f P ru ss ia

, P A

T

0.

7.

F

0.

7.

AIR RELEASE VALVEA

A

V

IN LINE FLUSHING STATION

AIR RELEASE VALVE WITH IN LINE FLUSHING STATION

GATE VALVE

TH

O

R N

TO

N

R O

AD

L

O W

P R

ES

SU

R E

SE

W

ER

PH

AS

E

1. ALL CONTRACTORS WORKING ON THIS PROJECT SHALL COMPLY WITH

REQUIREMENTS PROVIDED FOR IN PENNSYLVANIA'S UNDERGROUND UTILITY

LINE PROTECTION ACT 287 (1974) AS AMENDED BY ACT 121 (2008).

2. THE CONTRACTOR MUST COMPLY WITH ALL US DEPARTMENT OF LABOR,

OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION REGULATIONS AS

REVISED 1995, (OSHA ALL CONSTRUCTION METHODS AND MATERIALS SHALL

BE IN ACCORDANCE WITH PENNDOT SPECIFICATION PUBLICATION 408/2007,

LATEST REVISION, AND SHALL MEET OR EXCEED THE LOCAL MUNICIPALITY'S

STANDARD SPECIFICATIONS FOR CONSTRUCTION.

3. THE EXISTING UTILITES ARE BASED ON INFORMATION PROVIDED BY THE

UTILITY COMPANIES VIA PLANS AND SITE MARKOUT. VERTICAL INFORMATION

IS PROVIDED VIA RESPONDING USER'S PLAN AND IS APPROXIMATE. THE

LOCATIONS OF EXISTING UNDERGROUND UTILITIES ARE SHOWN IN AN

APPROXIMATE WAY ONLY AND HAVE NOT BEEN INDEPENDENTLY VERIFIED BY

THE OWNER OR ITS REPRESENTATIVE. THE CONTRACTOR SHALL DETERMINE

THE EXACT LOCATION OF ALL EXISTING UTILITIES BEFORE COMMENCING

WORK AND AGREES TO BE RESPONSIBLE FOR ANY AND ALL DAMAGES WHICH

MIGHT BE CAUSED BY THE CONTRACTOR'S FAILURE TO EXACTLY LOCATE AND

PRESERVE ANY UNDERGROUND UTILITIES.

4. IT IS THE CONTRACTOR'S RESPONSIBILITY TO CONTACT THE PENNSYLVANIA

ONE CALL SYSTEM (PHONE: 1-800-242-1776) THREE WORKING DAYS IN

ADVANCE OF ANY EXCAVATION FOR THE MARK-OUT OF THE LOCATION OF

UTILITIES AND NOTIFICATION OF COMMENCEMENT OF WORK. IT IS THE

RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN ALL UTILITY MARKINGS

WITHIN THE PROJECT LIMITS FOR THE DURATION OF THE PROJECT. IF UTILITY

MARKINGS ARE OBLITERATED, THE CONTRACTOR IS RESPONSIBLE FOR

CONTACTING PA ONE CALL FOR MARKOUT.

5. CONTRACTOR WILL MAKE EXPLORATION EXCAVATIONS AND LOCATE EXISTING

UNDERGROUND FACILITIES SUFFICIENTLY AHEAD OF CONSTRUCTION TO

PERMIT REVISIONS TO PLANS IF REVISIONS ARE NECESSARY. NOTIFY THE

ENGINEER OF WORK IF ANY DISCREPANCIES IN UTILITY LINE LOCATIONS ARE

FOUND.

6. CONTRACTOR IS REQUIRED TO TAKE PRECAUTIONARY MEASURES TO

PROTECT THE UTILITY LINES SHOWN HEREON AND ANY OTHER EXISTING

LINES NOT OF RECORD OR NOT SHOWN ON THESE PLANS.

7. PENNONI ASSOCIATES INC MAKES NO CLAIM AS TO THE ACCURACY OF THE

UNDERGROUND UTILITIES SHOWN ON THESE PLANS. THE CONTRACTOR IS

RESPONSIBLE FOR LOCATING AND VERIFYING THE DEPTH OF THE EXISTING

UTILITIES; IN THE EVENT OF A UTILITY CONFLICT, THE ENGINEER OF WORK

SHALL BE NOTIFIED.

8. IF IT IS NECESSARY TO RELOCATE OR CONNECT INTO EXISTING UTILITIES

WITHIN PENNDOT AND/OR TOWNSHIP RIGHT-OF-WAY, IT WILL BE THE

RESPONSIBILITY OF THE UTILITY OR THEIR APPOINTED CONTRACTOR TO

OBTAIN THE NECESSARY PERMITS FROM PENNDOT AND/OR THE TOWNSHIP.

9. IT IS THE CONTRACTORS SOLE RESPONSIBILITY TO GRADE ADJUST/RELOCATE

OR HAVE ADJUSTED OR RELOCATED BY THE APPROPRIATE UTILITY COMPANY,

ALL MANHOLES, VALVE COVERS, ETC. WITHIN THE PROJECT LIMITS.

10. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROPERLY BACKFILLING AND

COMPACT ALL TRENCHES. NO TRENCHES ARE TO BE LEFT OPEN AFTER

COMPLETION OF WORK FOR THE DAY. ALL CONSTRUCTION AREAS ARE TO BE

KEPT IN A CONDITION THAT ALLOWS FOR SAFE MOVEMENT OF BOTH

VEHICULAR AND PEDESTRIAN TRAFFIC. ANY EXCESS MATERIAL FROM

TRENCHING SHALL BE DELIVERED TO A LAWFUL SITE LOCATION BY THE

CONTRACTOR AT THEIR OWN EXPENSE.

11. A PRE-CONSTRUCTION MEETING SHALL BE HELD BETWEEN PENNDOT, THE

TOWNSHIP, CONTRACTOR, ENGINEER AND ALL UTILITY COMPANIES TO

CLARIFY AND COORDINATE ALL CONSTRUCTION DETAILS.

12. THE EXISTING TOPOGRAPHIC INFORMATION AND BASE SURVEY INFORMATION

WAS PROVIDED BY PENNONI ASSOCIATES INC. THE CONTRACTOR IS SOLELY

RESPONSIBLE FOR VERIFYING THE ACCURACY OF THE EXISTING

TOPOGRAPHIC AND BASE SURVEY INFORMATION PROVIDED IN THESE PLANS.

THE CONTRACTOR SHOULD CONTACT THE ENGINEER BEFORE PROCEEDING

WITH CONSTRUCTION IF THERE ARE ANY DIFFERENCES BETWEEN THE FIELD

CONDITIONS AND BASE SURVEY SHOWN ON THE PLANS.

13. THE PERMITTEE SHALL INSURE THAT THE SIGHT DISTANCE OF THE

DRIVEWAYS SERVICING PROPERTIES WITHIN THE LIMITS OF WORK OR AT

PUBLIC INTERSECTIONS IS NOT REDUCED UNLESS EXISTING AND PROPOSED

VALUES EXCEED THE DESIRABLE VALUES SPECIFIED IN THE PENNSYLVANIA

CODE, TITLE 67, TRNSPOTATION, CHAPTER 441.8(H)(1)] AS A RESULT OF THE

WORK PERFORMED IN ACCORDANCE WITH THE STATE HIGHWAY OCCUPANCY

PERMIT.

14. NO UNSUITABLE MATERIAL IS TO BE USED IN ANY PORTION OF THE ROADWAY

CONSTRUCTION. REMOVE ANY SUBGRADE THAT CANNOT BE PROPERLY

COMPACTED AND TREAT AS UNSUITABLE MATERIAL. UNDERCUTTING AND/OR

STABILIZATION MAY BE REQUIRED. THE SUBGRADE MUST BE APPROVED BY A

PENNDOT REPRESENTATIVE PRIOR TO PLACEMENT OF THE SUBBASE.

15. PEDESTRIANS MUST BE ACCOMMODATED AT ALL TIMES DURING

CONSTRUCTION.

16. EMPLOY CONSTRUCTION METHODS AND MEANS THAT KEEP DUST TO A

MINIMUM. PROVIDE FOR THE DISTRIBUTION OF WATER ON THE PROJECT FOR

THE PURPOSE OF LIMITING DUST. THE MATERIALS AND METHODS USED FOR

WATER LAYING ARE SUBJECT TO THE APPROVAL OF THE ENGINEER. PROVIDE

FOR THE PROMPT REMOVAL FROM EXISTING PAVING OF ALL DIRT AND OTHER

MATERIALS THAT HAVE SPILLED, WASHED UPON, OR OTHERWISE DEPOSITED

THEREON BY HAULING AND OTHER OPERATIONS. PROVIDE A STREET

SWEEPER TO PICK UP ANY TRACKING FROM CONSTRUCTION VEHICLES FOR

THIS PROJECT.

17. NO TRACKING OF MUD OR SEDIMENT SHALL BE PERMITTED ONTO PUBLIC

ROADS AND OUTSIDE THE LIMITS OF CONSTRUCTION. REMOVE ANY SEDIMENT

TRACKED ONTO PUBLIC ROADWAYS AND RETURN TO THE CONSTRUCTION

SITE.

18. MATERIAL CERTIFICATIONS MUST BE PROVIDED BY AN APPROVED

MANUFACTURER LISTED IN THE DEPARTMENT'S PUBLICATION 35, BULLETIN 15,

FOR ALL MATERIALS AND STRUCTURES WITHIN THE PENNDOT RIGHT-OF-WAY.

19. ALL STRUCTURES SHALL BE DESIGNED FOR HS-25 LOADING.

20. UNLESS OTHERWISE INDICATED ON THE PLANS, ALL BACKFILL WITHIN THE

ROADWAY AND UNDER CURB, SIDEWALK, AND DRIVEWAYS SHALL CONSIST OF

PENNDOT 2A STONE.

GENERAL NOTES:

THRN 0310.02

SK

06/22/2025

CF

SHEET OF2 6

REDUCER

BID PLANS

4 OF 6PLAN AND PROFILE CS1002

EXISTING UNDERGROUND CONDUIT

EXISTING FIRE HYDRANT

0+00

2.

2.

1+00

0.

9.

2+00

6.

6.

3+00

4.

4.

4+00

3.

2.

5+00

3.

3.

6+00

4.

4.

7+00

5.

5.

8+00

7.

7.

9+00

8.

8.

10+00

8.

8.

25 10+22.46 468.2 468.2347

1.

8.

5.

3.

3.

3.

4.

6.

8.

9.

4' COV. MIN.

(TYP)

MIN.

3' CLEARANCE

MIN.

3' CLEARANCE

PROPOSED 3" FORCE MAIN

PROPOSED 3"

GATE VALVE

PROPOSED

AIR RELEASE

VALVE

THORNTON ROAD(SR 4017)

(33' WIDE)

RETAINED AS ROW OF

BROADMEADOWS FARM

(33' WIDE)

G

LE

N M

IL

LS

R O

AD

(S

R

(5 0'

W

ID

E)

G

LE

N M

IL

LS

R O

AD

(S

R

(3 3'

W

ID

E)

PROPOSED 3" FORCE MAIN

INSTALLED VIA

DIRECTIONAL DRILLING

IN-LINE FLUSHING

CONNECTION

AIR

RELEASE

VALVE

EXISTING 3"

GATE VALVE

VA

V

CONNECT TO 3"

GATE VALVE

SR4017

SEG 0010

OFFSET 0980

1 14"-INCH

SERVICE LATERAL

(TYP.)

START OF WORK

1 14" SERVICE LATERAL TO

REST ROOM FACILITY

( 140 Feet)

(SEE NOTE ON DRWG CM1002

V

3" GATE

VALVE

.2

5'

MANUFACTURED

3"X3"X2" WYE

W/45° BEND

END WORK

CURB STOP

ASSEMBLY

MANHOLE W/AIR

RELEASE

SEE NOTE

8 BELOW

AIR

RELEASE

VALVE

A

APPROXIMATE EXISTING PROPERTY LINE/RIGHT-OF-WAY LINE

EXISTING DOUBLE YELLOW LINE

EXISTING PIPE SIZE/MATERIAL

EXISTING PHONE LINE

EXISTING WATER MAIN

EXISTING UTILITY POLE

EXISTING EDGE OF PAVEMENT

EXISTING OVERHEAD ELECTRIC

LEGEND

EXISTING MAJOR CONTOUR

EXISTING MINOR CONTOUR

EXISTING FENCE

EXISTING BRUSH

PROPOSED LOW PRESSURE FORCE MAIN W/SIZE

EXISTING DECIDUOUS TREE

LATERAL LOCATION (11

4" Ø)

APPROXIMATE TOP OF BANK

4' COV. MIN.

(TYP)

0+00

8.

8.

8.

1+00

7.

7.

6.

1+99.26

6.

6.

MIN.

3' CLEARANCE

PROPOSED

2" FORCE MAIN

P:

\P ro jec ts\

TH

RN

TH

OR

NB

UR

Y\

TH

RN

- T

HO

RN

TO

N

RO

AD

S

EW

ER

\D

ES

IG

N\

PE

RM

IT

P

LA

NS

\C S1

- P

ER

M

IT

TE

D:

4/

/2

1:

P M, B

Y:

Se da K or

ST

YL

E:

Pe nn on i N

CS

_A M

TR

AK

.st b

PR

OJ

EC

T

ST

AT

US

B Y

N O

D

A

TE

R E

V

IS

IO

N

S

P R

O P

O S

E D

L O

W P

R E

S S

U R

E P

LA

N

P

R O

FI

LE

1"=40'

CFAPPROVED BY

DRAWN BY

DRAWING SCALE

DATE

PROJECT

ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES

ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE

PROJECT. THEY ARE NOT INTENDED OR REPRESENTED

TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON

THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER

PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION

OR ADAPTATION BY PENNONI ASSOCIATES FOR THE

SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS

SOLE RISK AND WITHOUT LIABILITY OR LEGAL

EXPOSURE TO PENNONI ASSOCIATES; AND OWNER

SHALL INDEMNIFY AND HOLD HARMLESS PENNONI

ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND

EXPENSES ARISING OUT OF OR RESULTING THEREFROM.

A

LL

D

IM

E N

S

IO

N S

M U

S T

B E

V E

R

IF

IE

D

B Y

C O

N

TR

A C

TO

R

A N

D O

W N

E R

M U

S T

B E

N O

TI

FI

E D

O F

A N

Y D

IS

C

R E

P A

N C

IE

S

B E

FO

R

E P

R O

C E

E D

IN

G

W

IT

H W

O R

K

NORTH

PE

N

N O

N I A

SS

O

C

IA

TE

S

IN

C

H or iz on D riv e, S ui te

Ki ng o f P ru ss ia

, P A

T

0.

7.

F

0.

7.

NOTES:

1. FORCE MAIN AND LATERALS TO BE INSTALLED VIA DIRECTIONAL DRILLING

2. FORCE MAIN AND LATERALS TO BE HDPE (SDR-11) PIPE. ALL CONNECTIONS TO BE MADE VIA

BUTT FUSION

3. FORCE MAIN TO BE LOCATED A MINIMUM OF 2.5 FEET FROM NEAREST UTILITY POLE OR

STRUCTURE.

4. ALL EXCAVATIONS WITHIN THE RIGHT-OF-WAY, CARTWAY, OR WITHIN 3 FEET OF STRUCTURE, INCLUDING UTILITY POLES, THE EDGE OF THE PAVING SHALL BE BACKFILLED WITH PENNDOT

2A STONE COMPACTED IN 6-INCH LIFTS TO A MAXIMUM DRY DENSITY OF 95-PERCENT

5. ALL LATERAL LOCATIONS INDICATED ARE APPROXIMATE. FINAL LOCATION TO BE DETERMINED

AFTER CONSULTATION OF PROPERTY OWNER

6. ALL PROPOSED SEWER TO MEET PADEP REQUIREMENTS FOR SEPARATION FROM EXISTING

WATER MAIN (MIN 18-INCHES VERTICAL OR 10-FOOT HORIZONTAL

7. ALL FORCE MAIN AND LATERALS TO HAVE A MINIMUM 4-FOOT OF COVER

8. CONTRACTOR TO EXCAVATE AND DETERMINE ELEVATION OF BOTTOM OF EXISTING STORM

SEWER LINES AT THE INTERSECTION OF THORNTON ROAD AND GLEN MILLS ROAD A MINIMUM

OF 3 WEEKS PRIOR TO COMMENCEMENT OF ANY CONSTRUCTION. PROVIDE TOWNSHIP WITH

ELEVATIONS. NO LATER THAN 3-WORKING DAYS AFTER COMPLETION OF EXCAVATION.

9. ALL WORK SHALL BE CONDUCTED WITHIN THE LIMIT OF THE EXISTING RIGHT-OF-WAY. NO

WORK, EQUIPMENT OR OTHER ACCESS SHALL OCCUR ON PRIVATE PROPERTY UNLESS

WRITTEN PERMISSION IS GRANTED BY THE PROPERTY OWNER.

10. THE CONTRACTOR SHALL LIMIT THE EARTH DISTURBANCE ASSOCIATED WITH THIS PROJECT.

NO ADDITIONAL EARTH DISTURBANCE SHALL OCCUR WITHOUT CONCURRENCE FROM THE

TOWNSHIP.

%,D 3/ANS

00 40' 80'

&A// ��������������

&A// %EFORE <O8 D,*

BEFORE YOU DIG ANYWHERE IN PENNSYLVANIA

PA. ACT 287 OF 1974 REQUIRES THREE WORKING DAYS

NOTICE TO UTILITIES BEFORE YOU EXCAVATE, DRILL OR

BLAST PENNSYLVANIA ONE-CALL SYSTEM, INC.

SERIAL NUMBER(S): 20243481059

20243391914

TH

O

R N

TO

N

R O

A D

L O

W P

R E

S S

U R

E S

E W

E R

P

H A

S E

TH

O R

N

TO

N R

O A

D

TH

O R

N B

U R

Y , P

A

TO

W N

S H

IP

D

R

IV

E C

H E

Y N

E Y

, P A

TO

W

N S

H

IP

O F

TH

O

R N

B U

R Y

THRN 0310.02

SK

06/22/2025

CF

&S����

SHEET 3 6OF

0+00

6.

6.

1+00

3.

3.

2+00

9.

9.

3+00

4.

4.

4+00

9.

9.

5+00

1.

1.

6+00

4.

4.

7+00

4.

4.

07 7+11.61 434.2 434.2246

6.

1.

6.

2.

6.

7.

4.

1 14" LATERAL FROM

FUTURE MAINTENANCE

BUILDING

4' COV. MIN.

(TYP)

IN LINE FLUSHING

MANHOLE W/AIR RELEASE

PROPOSED

2" X 1 14 "

REDUCER

IN LINE FLUSHING

MANHOLE

PROPOSED

2" FORCE MAIN

RETAINED AS RO

W

O F

BRO

ADM

EADO

W

S FARM

(33' W

IDE)

GLEN MILLS ROAD (SR4016)

(50' WIDE)

GLEN MILLS ROAD (SR4016)

(33' WIDE)

TBTBTBTBTBTBTBTBTBTBTBTBTB

UNDERGROUND ELECTRIC LINE (TO

BE ABANDONED)

APPROXIMATE LOCATION

FUTURE ELECTRIC LINE

V

12.25'

END OF LATERAL

PROVIDE CURB STOP

ASSEMBLY

1 14" LATERAL TO FUTURE

MAINTENANCE BUILDING

MANUFACTURED

45° BEND

1 14" SERVICE LATERAL

TO REST ROOM FACILITY

(± 140 Feet)

(SEE NOTE BELOW)

3" GATE

VALVE

MANUFACTURED

3"X3"X2" WYE

W/45° BEND

END WORK

5.0'

CURB STOP

ASSEMBLY

SEE NOTE 8 ON

DRWG CM1001

IN LINE

FLUSHING

MANHOLE

2"x1 14" REDUCER

(W/CAP)

AIR RELEASE

IN LINE FLUSHING

MANHOLE

±25' TO EOP

A

AIR

RELEASE

VALVE

5.0'

SEE NOTE 2

BELOW

A

4' COV. MIN.

(TYP)

0+00

8.

8.

8.

1+00

7.

7.

6.

1+99.26

6.

6.

MIN.

3' CLEARANCE

PROPOSED

2" FORCE MAIN

P:

\P ro jec ts\

TH

RN

TH

OR

NB

UR

Y\

TH

RN

- T

HO

RN

TO

N

RO

AD

S

EW

ER

\D

ES

IG

N\

PE

RM

IT

P

LA

NS

\C S1

- P

ER

M

IT

TE

D:

4/

/2

1:

P M, B

Y:

Se da K or

ST

YL

E:

Pe nn on i N

CS

.st b

PR

OJ

EC

T

ST

AT

US

BY

N

O

D

AT

E R

EV

IS

IO

N

S

APPROVED BY

DRAWN BY

DRAWING SCALE

DATE

PROJECT

ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES

ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE

PROJECT. THEY ARE NOT INTENDED OR REPRESENTED

TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON

THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER

PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION

OR ADAPTATION BY PENNONI ASSOCIATES FOR THE

SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS

SOLE RISK AND WITHOUT LIABILITY OR LEGAL

EXPOSURE TO PENNONI ASSOCIATES; AND OWNER

SHALL INDEMNIFY AND HOLD HARMLESS PENNONI

ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND

EXPENSES ARISING OUT OF OR RESULTING THEREFROM.

AL

L

D

IM

EN

SI

O N

S M

U

ST

B E

VE

R

IF

IE

D B

Y C

O N

TR

AC

TO

R

AN

D

O W

N

ER

M U

ST

B

E N

O

TI

FI

ED

O F

AN

Y

D

IS

C R

EP

AN

C

IE

S

BE

FO

R

E

PR

O C

EE

D

IN

G

W

IT

H W

O R

00 40' 80'

PR

O

PO

SE

D L

O W

P R

ES

SU

R E

PL

AN

PR

O

FI

LE

1"=40'

TH

O

R N

TO

N

R O

AD

L

O W

P R

ES

SU

R E

SE

W

ER

PH

AS

E

TH

O

R N

TO

N

R O

AD

TH

O R

N

BU

R Y, P A

TO

W N

SH

IP

D R

IV

E

C H

EY

N

EY

, P

A

TO

W

N

SH

IP

O

F

TH

O R

N

BU

R Y

THRN 0310.02

SK

06/22/2025

CF

CS1002

SHEET 4 6OF

PE

N

N O

N I A

SS

O

C

IA

TE

S

IN

C

H or iz on D riv e, S ui te

Ki ng o f P ru ss ia

, P A

T

0.

7.

F

0.

7.

NOTES:

1. LATERAL TO THE REST ROOM BULDING TO BE INSTALLED TO WITHIN 20 FEET

OF BUILDING.

2. CONTRACTOR TO LOCATE EXISTING UNDERGROUND CONDUIT VIA TEST PITS

AS REQUIRED A MINIMUM OF 3 WEEKS PRIOR TO COMMENCEMENT OF ANY

INSTALLATION. MAIN TO BE LOCATED AT ALL LOCATIONS WHERE CONDUIT IS

MARKED AND WITHIN 6-FEET OF THE PROPOSED FORCE MAIN/LATERAL TO

MAINTENANCE BUILDING.

3. ALIGNMENT OF 1 14"- INCH LATERAL TO MAINTENANCE BUILDING MAY BE

ADJUSTED SLIGHTLY TO AVOID SURFACE FEATURES AND MAXIMIZE

DISTANCE FROM TOP OF SLOPE.

BID PLANS

BEARING AND REQUIRED,

SQUARE FEET

A

A

P:

\P ro jec ts\

TH

RN

TH

OR

NB

UR

Y\

TH

RN

- T

HO

RN

TO

N

RO

AD

S

EW

ER

\D

ES

IG

N\

PE

RM

IT

P

LA

NS

\C S6

- P

ER

M

IT

TE

D:

4/

/2

1:

P M, B

Y:

Se da K or

ST

YL

E:

Pe nn on i N

CS

.st b

PR

OJ

EC

T

ST

AT

US

BY

N

O

D

AT

E R

EV

IS

IO

N

S

APPROVED BY

DRAWN BY

DRAWING SCALE

DATE

PROJECT

ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES

ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE

PROJECT. THEY ARE NOT INTENDED OR REPRESENTED

TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON

THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER

PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION

OR ADAPTATION BY PENNONI ASSOCIATES FOR THE

SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS

SOLE RISK AND WITHOUT LIABILITY OR LEGAL

EXPOSURE TO PENNONI ASSOCIATES; AND OWNER

SHALL INDEMNIFY AND HOLD HARMLESS PENNONI

ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND

EXPENSES ARISING OUT OF OR RESULTING THEREFROM.

AL

L

D

IM

EN

SI

O N

S M

U

ST

B E

VE

R

IF

IE

D B

Y C

O N

TR

AC

TO

R

AN

D

O W

N

ER

M U

ST

B

E N

O

TI

FI

ED

O F

AN

Y

D

IS

C R

EP

AN

C

IE

S

BE

FO

R

E

PR

O C

EE

D

IN

G

W

IT

H W

O

N O

N I A

SS

O

C

IA

TE

S

IN

C

H or iz on D riv e, S ui te

Ki ng o f P ru ss ia

, P A

T

0.

7.

F

0.

7.

DETAIL- TYPICAL LATERAL VALVE ASSEMBLY

N.T.S.

CM6001

DETAIL- TYPICAL BLOCKING FOR HORIZONTAL THRUSTS UP TO

150 PSI WORKING PRESSUREN.T.S.

CM6001

D

ET

AI

LS

AS SHOWN

DETAIL- AIR RELEASE

IN LINE FLUSHING MANHOLEN.T.S.

CM6001

TH

O

R N

TO

N

R O

AD

L

O W

P R

ES

SU

R E

SE

W

ER

PH

AS

E

TH

O

R N

TO

N

R O

AD

TH

O R

N

BU

R Y, P A

TO

W N

SH

IP

D R

IV

E

C H

EY

N

EY

, P

A

TO

W

N

SH

IP

O

F

TH

O R

N

BU

R Y

THRN 0310.02

SK

06/22/2025

CF

CS6001

SHEET 5 6OF

DETAIL-

N.T.S.

MANHOLE FRAME AND COVER 3

CM6001

DETAIL- IN LINE FLUSHING MANHOLE - IN PAVING

N.T.S.

CM6001

DETAIL- AIR RELEASE MANHOLE

N.T.S.

CM6001

BID PLANS

DETAIL- IN LINE FLUSHING MANHOLE - IN GRASS

N.T.S.

CM6001

MAINTENANCE AND PROTECTION OF TRAFFIC NOTES

1. ALL TRAFFIC CONTROL SHALL CONFORM TO PENNDOT PUBLICATION 213

"TEMPORARY TRAFFIC CONTROL GUIDELINES, LATEST EDITION.

2. ALL WORK SHALL BE IN ACCORDANCE WITH THE CONDITIONS INDICATED ON THE

APPROVED PENNDOT HIGHWAY OCCUPANCY PERMIT.

3. ALL TRENCHES TO BE TEMPORARILY PAVED AT THE END OF EACH WORKDAY WITH

2 INCHES OF HOT MIX MATERIAL.

4. FURNISH, ERECT, PLACE AND MAINTAIN TRAFFIC CONTROL SIGNS AND DEVICES

AND MAINTAIN TRAFFIC DURING HOURS OF CONSTRUCTION AND AT ALL OTHER

TIMES IN ACCORDANCE WITH THE METHODS INDICATED ON THESE DRAWINGS AND,

· PENNDOT PUBLICATION 213, WORK ZONE TRAFFIC CONTROL GUIDELINES.

· MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (MUTCD), 2009 EDITION.

· PA CODE, TITLE 67, CHAPTER 212, OFFICIAL TRAFFIC CONTROL DEVICES.

· PENNDOT PUBLICATION 35, APPROVED CONSTRUCTION MATERIALS (BULLETIN

15).

· PENNDOT PUBLICATION 111, TRAFFIC CONTROL PAVEMENT MARKING AND

SIGNING STANDARDS (TC-8600).

· PENNDOT PUBLICATION 408/2020, SPECIFICATIONS.

· PENNDOT PUBLICATION 46, TRAFFIC ENGINEERING MANUAL.

· PENNDOT PUBLICATION 72M, STANDARDS FOR ROADWAY CONSTRUCTION,

SERIES RC-1M TO 100M.

· PENNDOT PUBLICATION 212, OFFICIAL TRAFFIC CONTROL DEVICES.

· PENNDOT PUBLICATION 236, HANDBOOK OF APPROVED SIGNS.

8. REMOVE THESE DEVICES IMMEDIATELY UPON COMPLETION OF THE WORK.

9. NOTIFY THE DISTRICT 6-0 REGIONAL TRAFFIC MANAGEMENT CENTER (RTMC),

610-205-6934, FIFTEEN (15) MINUTES IN ADVANCE OF ANY PROPOSED LANE OR

SHOULDER RESTRICTION, ROAD CLOSURE, OR ANY OPERATION IMPEDING THE

FLOW OF TRAFFIC. NOTIFY THE RTMC WHEN THE ROAD IS RESTORED TO NORMAL

OPERATION.

10. THE CONTRACTOR IS REQUIRED TO SUBMIT A ROAD RESTRICTION FORM TO THE

DISTRICT 6-0 PRESS OFFICE ONE WEEK IN ADVANCE OF ANY LANE CLOSURES AND

TWO WEEKS IN ADVANCE OF ANY FULL CLOSURES THAT NECESSITATE A DETOUR.

THE FORM IS AVAILABLE ONLINE AT

https://www.penndot.pa.gov/RegionalOffices/district-6/Documents/Road%20Restriction%20Form.pdf OR BY CALLING 610-205-6797.

11. ALL WORKERS SHALL FOLLOW REGULATIONS SET FORTH IN TITLE 23 OF THE CODE

OF FEDERAL REGULATIONS (CFR) PART 634 EFFECTIVE NOVEMBER 24, 2008 IN

REGARDS TO THE WORKER'S SAFETY APPAREL.

12. PERMITTEE MUST ARRANGE FOR INSPECTION OF ALL TRAFFIC CONTROL DEVICES

PRIOR TO START OF WORK.

13. COVER OR REMOVE ALL CONFLICTING SIGNS AND ERADICATE ALL CONFLICTING

PAVEMENT MARKINGS. DO NOT PLACE ADHESIVE ON FACE OF THE SIGN.

14. ALL DISTANCES MAY BE ADJUSTED SLIGHTLY TO FIT FIELD CONDITIONS.

15. NO TRAFFIC RESTRICTIONS OR LANE CLOSURES ARE PERMITTED BETWEEN 6:00

AM AND 9:00 AM AND BETWEEN 3:00 PM AND 7:00 PM MONDAYS THROUGH FRIDAYS

OR ON LEGAL HOLIDAYS AND WEEKENDS ASSOCIATED WITH LEGAL HOLIDAYS. ALL

RESTRICTIONS AND CLOSURES ARE TO BE REMOVED BY NOON ON THE DAY PRIOR

TO THE LEGAL HOLIDAY.

16. PROPERLY BARRICADE AND SECURE THE WORK AREA DURING NON-WORKING

HOURS TO PROVIDE FULL WIDTH USE FOR THROUGH TRAFFIC LANES UNDER

SHORT TERM OPERATIONS.

17. THIS TRAFFIC CONTROL PLAN DOES NOT RELIEVE THE CONTRACTOR OF HIS

RESPONSIBILITY AS SPECIFIED IN SECTION 901.3(a) OF PUBLICATION 408.

18. ALL SIGNS TO BE REFLECTORIZED OR ILLUMINATED DURING HOURS OF DARKNESS.

19. MODIFY EXISTING TRAFFIC CONTROL DEVICES AS REQUIRED FOR THE DURATION

OF THE WORK.

20. MAINTAIN ACCESS TO ALL ADJACENT PROPERTIES AT ALL TIMES.

21. NOTIFY ALL GOVERNMENTAL, POLICE, FIRE AND EMERGENCY SERVICES WITHIN

THE IMMEDIATE AREA. NOTICE MUST BE GIVEN AT LEAST 48 HOURS PRIOR TO

START OF WORK.

22. DURING HOURS OF DARKNESS ALL CHANNELIZING DEVICES MUST HAVE EITHER 350

IN. OF REFLECTORIZED MATERIAL OR TYPE C LIGHT. TYPE C LIGHT SHALL BE

PLACED ON EACH DEVICE IN TRANSITION AREAS.

23. DROPOFFS CREATED BY CONSTRUCTION OPERATIONS SHALL BE TREATED

CONSISTENT WITH PUBLICATION 408, SECTION 901.3(J).

24. MAINTENANCE AND PROTECTION OF TRAFFIC DURING CONSTRUCTION SHALL BE IN

ACCORDANCE WITH APPLICABLE FIGURES PATA 107 AND 109-B IN PENNDOT

PUBLICATION 213 "TEMPORARY TRAFFIC CONTROL GUIDELINES", APRIL, 2022 AND

TITLE 67 PA CODE, CHAPTER 212 "OFFICIAL TRAFFIC CONTROL DEVICES" DATED

FEBRUARY 4, 2006 OR MOST CURRENT.

25. MOUNT ALL LONG-TERM ADVANCE WARNING SIGNS ON TYPE III BARRICADES

UNLESS OTHERWISE NOTED OR INSTRUCTED BY DISTRICT OFFICE.

26. ALL SIGNS AND DEVICES TO BE MAINTAINED IN NEW OR LIKE NEW CONDITION.

27. DRIVEWAYS WILL BE KEPT ACCESSIBLE AT ALL TIMES. LOCATE ALL SIGNS SO THAT

SIGHT DISTANCES WILL NOT BE OBSTRUCTED AT DRIVEWAYS AND LOCAL ROADS.

28. ALL CHANNELIZING DEVICES, BARRICADES AND SIGNS SHALL HAVE TYPE III OR

BETTER PRISMATIC RETROREFLECTIVE SHEETING. SHEETING SHALL BE APPROVED

AND LISTED IN PENNDOT PUBLICATION 35 (BULLETIN 15).

29. PERMITTEE SHALL NOTIFY LOCAL EMERGENCY AUTHORITIES (E.G., POLICE, FIRE,

MEDICAL), AFFECTED BUSINESS, SCHOOL DISTRICT(S), THE GENERAL PUBLIC, THE

DISTRICT PERMIT MANAGER AND THE DISTRICT APRAS COORDINATOR AT LEAST

FOURTEEN DAYS PRIOR TO ANY SIGNIFICANT TRAFFIC IMPACTS (E.G., LATERAL

WIDTH RESTRICTIONS LESS THAN 16 FEET, DETOURS).

30. REMOVE ALL SHORT-TERM WORK ZONE TRAFFIC CONTROL SIGNINGUPON

COMPLETION OF THAT DAY'S WORK PERIOD.

31. RESTRICTING TRAFFIC FLOW WITHIN THE WORK AREA SHALL BE MINIMIZED TO

PREVENT TRAFFIC CONGESTION AND UNSAFE TRAFFIC CONDITION.

32. NOTIFY THE LOCAL MUNICIPALITY WHERE SIGNALIZED INTERSECTIONS FALL

WITHIN THE WORK ZONE. DO NOT FLAG A SIGNALIZED INTERSECTION WITHOUT

THE MUNICIPALITY PLACING THE SIGNAL ON FLASH.

33. THE CONTRACTOR SHALL COMPLY WITH ACT 229 OF DECEMBER 2002 DURING

CONSTRUCTION ACTIVITIES WITHIN PENNDOT'S RIGHT-OF-WAY.

34. ACCEPTABLE SIGHT DISTANCE MUST BE MAINTAINED ON ALL ROADS AT ALL TIMES.

1'-0"

MIN

1'-0"

MIN

SAW-CUT FULL DEPTH (TYP.) ALL SIDES

TACK COAT OF TYPE E-1

BITUMINOUS MATERIAL

EXISTING

WEARING

COURSE

PROPOSEDEXISTING

5 1/2" SUPERPAVE ASPHALT MIXTURE DESIGN, BASE

COURSE, PG 64S-22 (TYP.), 3.0 TO < 10.0 MILLION ESALs 25mm MIXTURES

2 1/2" SUPERPAVE ASPHALT MIXTURE DESIGN, BINDER

COURSE, PG 64S-22 (TYP.), 3.0 TO < 10.0 MILLION ESALs 19mm MIXTURES

1 1/2" SUPERPAVE ASPHALT MIXTURE DESIGN, WEARING

COURSE, PG 64S-22 (TYP.), 3.0 TO < 10.0 MILLION ESALs 9.5mm MIXTURES, SRL-H

PENNDOT #2A STONE

P:

\P ro jec ts\

TH

RN

TH

OR

NB

UR

Y\

TH

RN

- T

HO

RN

TO

N

RO

AD

S

EW

ER

\D

ES

IG

N\

PE

RM

IT

P

LA

NS

\C S6

- P

ER

M

IT

TE

D:

4/

/2

1:

P M, B

Y:

Se da K or

ST

YL

E:

Pe nn on i N

CS

.st b

PR

OJ

EC

T

ST

AT

US

BID PLANS

BY

N

O

D

AT

E R

EV

IS

IO

N

S

APPROVED BY

DRAWN BY

DRAWING SCALE

DATE

PROJECT

ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES

ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE

PROJECT. THEY ARE NOT INTENDED OR REPRESENTED

TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON

THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER

PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION

OR ADAPTATION BY PENNONI ASSOCIATES FOR THE

SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS

SOLE RISK AND WITHOUT LIABILITY OR LEGAL

EXPOSURE TO PENNONI ASSOCIATES; AND OWNER

SHALL INDEMNIFY AND HOLD HARMLESS PENNONI

ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND

EXPENSES ARISING OUT OF OR RESULTING THEREFROM.

AL

L

D

IM

EN

SI

O N

S M

U

ST

B E

VE

R

IF

IE

D B

Y C

O N

TR

AC

TO

R

AN

D

O W

N

ER

M U

ST

B

E N

O

TI

FI

ED

O F

AN

Y

D

IS

C R

EP

AN

C

IE

S

BE

FO

R

E

PR

O C

EE

D

IN

G

W

IT

H W

O

N O

N I A

SS

O

C

IA

TE

S

IN

C

H or iz on D riv e, S ui te

Ki ng o f P ru ss ia

, P A

T

0.

7.

F

0.

7.

ROADWAY IN USE

10' LANE, MIN.

NOTES:

1. SAFETY BUILD-UP MUST BE UTILIZED ANY PLACE WHERE OPEN EXCAVATION ALONG

ADJACENT ROADWAYS RESULTS IN A DROP OFF GREATER THAN 2 INCHES.

2. IF IT IS NECESSARY TO REMOVE THE EXISTING LANE EDGE LINE, PLACE A TEMPORARY 4"

WHITE EDGE LINE AT THE EDGE OF ROADWAY. REFER TO PUBLICATION 213 SECTION C.

WORK AREA

CHANNELIZING DEVICE

BUILD-UP SAFETY SLOPE

EMBANKMENT OR SUBBASE

CONSTRUCT SAFETY SLOPE WHEN

EXCAVATION EXCEED 2 INCHES

23" MAX.

TOP OF EXCAVATION

TOP OF SUBBASE, TOP OF

BASE COURSE OR SUBBASE

SEE NOTE 2

EXISTING PAVEMENT

EDGE OF ROADWAY

PAVEMENT

CS 6002

DETAIL- DROPOFF TREATMENT FOR MAINTAINING TWO LANES OF TRAFFIC

N.T.S.

D

ET

AI

LS

M

AI

N

TE

N

AN

C

E

AN

D P

R O

TE

C

TI

O

N O

F

TR

AF

FI

C P

LA

N

SK

CF

CS6002

SHEET 6 6OF

TH

O

R N

TO

N

R O

AD

TH

O R

N

BU

R Y, P A

TO

W N

SH

IP

D R

IV

E

C H

EY

N

EY

, P

A

TO

W

N

SH

IP

O

F

TH

O R

N

BU

R Y

THRNM23001

AS NOTED

06/22/2025

TH

O

R N

TO

N

R O

AD

L

O W

P R

ES

SU

R E

SE

W

ER

PH

AS

E

CS 6002

DETAIL- STATE HIGHWAY TRENCH RESTORATION

N.T.S.

CS0001
CS0001
CS0002
CS0002
CS1001
CM1001
CS1002
CM-1002
CS6001
CS6001
CS6002
CS6002

File details come from the government source that posted it. Updated .