1-Permit-06122308 .pdf

PDF 23 KB Posted

Attached to
Thornton Road Low Pressure Sewer - Phase II
Solicitation number
US.196130
Issued by
Delaware County, Chicora Borough, Pennsylvania

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Name and Address of Permittee:

Thornbury Township 6 Township Drive Cheyney, PA 19319

County: Delaware

County Contact No.: (610) 480-1935

Issuing District Office: 6-0

District Contact No.: (610) 205-6790

Municipalities: Thornbury Township

Issue Date: 7/22/2025

Expiration Date: 7/22/2026

Application No.: 373276

Account No.:

Permit Fee: $ 0.00

Immediately upon completion of the work Permittee shall notify the permit office where application was made. Subject to all the conditions, agreements, restrictions, and regulations prescribed by the Pennsylvania Department of Transportation, (see in particular 67 Pa. Code, Chapter 212, 441 and 459 and State Highway Law, 36 P.S. Section 670 - 411, 420 and 421 ) and subject to the plans, special conditions, or restrictions herein set forth or attached hereto. This permit shall be located at the work site and shall be available for inspection by any police officer or Department representative.

Location and Description of Work Permit No.: 06122308

1 of 2 State Route #: 4017 Segment(s): From 0010 To 0010 Offset(s): From 0000 To 0980

641: Install Sub-surface Sewer Facility

2 of 2 State Route #: 4016 Segment(s): From 0064 To 0064 Offset(s): From 0169 To 1302

641: Install Sub-surface Sewer Facility

Permit Conditions Permit No.: 06122308

1 of 17 NOTIFY THE TRAFFIC MANAGEMENT CENTER AT 610-205-6500 PRIOR TO SETTING UP ANY

LANE CLOSURES OR RESTRICTIONS, AND WHEN THE CLOSURE/RESTRICTION IS

REMOVED.

2 of 17 CONTACT COUNTY PERMIT INSPECTOR AT LEAST 3 WORK DAYS PRIOR TO START OF

WORK AT 610-480-1935.

3 of 17 AN INSPECTOR, WHEN AVAILABLE, WILL BE ASSIGNED ON MORE THAN A SPOT

INSPECTION BASIS. PERMITTEE WILL BE CHARGED ALL INSPECTION COSTS INCURRED

BY THE DEPARTMENT.

4 of 17 THIS PERMIT AUTHORIZES WORK ONLY IN DEPARTMENT HIGHWAY RIGHT OF WAY.

5 of 17 2A COARSE AGGREGATE BACKFILL MATERIAL IS REQUIRED UNDER 67 PA CODE, SECTION 459.8 (G)(2) AND SECTION 703.2 OF PUBLICATION 408.

6 of 17 DEPARTMENT MUST BE NOTIFIED IN WRITING TWO WEEKS IN ADVANCE OF PRE-

CONSTRUCTION MEETING.

7 of 17 FULL LANE OVERLAY IS REQUIRED, AS PER REGULATION 459.8.

8 of 17 DEPARTMENT MUST BE NOTIFIED IN WRITING UPON COMPLETION OF WORK.

9 of 17 THE PERMITTEE IS REQUIRED TO USE HOT MIX OR WARM MIX MATERIAL FOR

TEMPORARY RESTORATION. COLD MIX WILL BE PERMITTED AT THE DISCRETION OF

THE DEPARTMENT. PERMITTEE MUST MAINTAIN A SMOOTH PAVEMENT SURFACE

SUITABLE FOR DRIVING FOR THE DURATION OF THE TEMPORARY PAVEMENT.

M-945P (6/12)

Highway Occupancy Permit Permit No.: 06122308

Page 1 of Permit # 06122308

Permit Conditions Permit No.: 06122308

10 of 17 SHOULDERS MUST BE RESTORED IN ACCORDANCE WITH APPROPRIATE SECTION OF

PUB. 408 AND ROADWAY CONSTRUCTION STANDARDS RC-25M.

11 of 17 ALL DISTURBED AREAS OUTSIDE THE PAVEMENT OR SHOULDER SHALL BE RESTORED

TO A CONDITION AT LEAST EQUAL TO THAT WHICH EXISTED BEFORE THE START OF

WORK.

12 of 17 NO LANES MAY BE RESTRICTED BETWEEN THE HOURS OF 6:00 AM TO 9:00 AM OR

BETWEEN THE HOURS OF 3:00 PM TO 6:00 PM.

13 of 17 PERMITTEE IS RESPONSIBLE FOR ENSURING THAT MUD, SILT AND OTHER DEBRIS IS

REMOVED FROM VEHICLES AND TIRES (BY POWER WASH, ETC.) BEFORE ENTERING

ONTO THE HIGHWAY.

14 of 17 CONTRACTOR MUST CONTACT PENNDOT'S DISTRICT PRESS OFFICE VIA EMAIL: RA-

PDD6PRESS@PA.GOV AT LEAST 5 WORK DAYS PRIOR TO ANY LANE CLOSURE AND 10

WORKING DAYS PRIOR TO ANY FULL LANE CLOSURE(S).

15 of 17 MATERIAL AND EQUIPMENT MAY NOT BE STORED WITHIN THE STATE R.O.W.

16 of 17 SPREADING, FINISHING AND COMPACTION OF THE TEMPORARY PAVEMENT MATERIAL

SHALL LEAVE THE SURFACE SMOOTH AND LEVEL WITH THE EDGE OF EXISTING

PAVEMENT. THE DISTANCE AT ANY POINT FROM A TEN (10) FOOT STRAIGHT EDGE TO

THE SURFACE SHALL NOT EXCEED ONE-HALF (1/2) INCH IN ANY DIRECTION FOR THE

DURATION OF TEMPORARY RESTORATION. LUMPS OR DEPRESSIONS EXCEEDING THIS

TOLERANCE SHALL BE CORRECTED BY REMOVING DEFECTIVE WORK AND REPLACING

WITH NEW MATERIAL AS DIRECTED.

17 of 17 Installation of approximately 1,030 linear feet of 2 & 3-inch low-pressure sanitary sewer force main along the west side of Thornton Road (S.R. 4017) and within the intersection of Thornton Road and Glen Mills Road (S.R. 4016) to service five (5) properties and the existing rest-room facilities within the Townships Park.

Acknowledgement of Completion

Permit work has been completed:

Date:

By:

Michael B. Carroll

Secretary of Transportation

Din Abazi, P.E.

District Executive

M-945P (6/12)

Highway Occupancy Permit Permit No.: 06122308

Page 2 of Permit # 06122308

File details come from the government source that posted it. Updated .