Attachment_5_-_Appendix_A_Fire_Suppression_System_List.xlsx

XLSX spreadsheet 14 KB Posted

Attached to
Fire Suppression
Solicitation number
F2B3AQ7123A001
Issued by

View the file

Other files

File Type Posted
Attachment_1_-_COMBO_Fire_Suppression_2.0.pdf PDF
Questions_and_Answers_2.pdf PDF
Questions_and_Answers.docx DOCX document
Fire_Suppression_-_Explanation_of_dates.xlsx XLSX spreadsheet
Attachment_3_-_Bid_Schedule.xlsx XLSX spreadsheet
Attachment_6_-_Appendix_B_PIV_List.xlsx XLSX spreadsheet
Attachment_7_-_Appendix_D_Backflow_List.xlsx XLSX spreadsheet
Attachment_2_-_PWS_Fire_Suppression_Inspections.pdf PDF
Attachment_4_-_Wage_Determination.pdf PDF
Attachment_1_-_COMBO_Fire_Suppression.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sheet1

Appendix A - Fire Suppression System List
Building #LocationMakeSprinkler Valve LocationTypeDate of FacilityDate System Installed
1102ECSSTD1956
1152LG SupplyGemSouth East Corner of Build.Wet19561998
1106Conference CenterGemBasementWet19561998
1108Admin OfficesFIRE PUMPBasementPUMP1954
1108Admin OfficesBasementWet /STD1954
1109Admin OfficesBasementWet/STD1954
1109Admin OfficeFIRE PUMPBasementPUMP1954
1201Steam PlantGrinnellBoiler RoomWet19542011
1201Pump HouseGrinnellPump HouseWet19541986
1208Munitions MxVikingBathroomWet19541993
1240Family SupportRm 602 - Rear Mech RmWet1956
1305HQ ABGRascoMech RoomWet/STD19841984
1305HQ ABGFIRE PUMPMech RoomPUMP19841984
1412TLFReliableBasementWet19652004
1412TLFReliableBasementDry19652004
1414VOQReliableBasement Storage RoomWet19662003
1414VOQReliableBasement Storage RoomDry19662003
1420VOQUnknownMech RoomWet19572001
1423TLFVictaulicMech RoomWet19842004
1423TLFReliable3rd floor closetDry19842004
1425The CommonsFirematicBasementWet19542002
1426VOQVictaulicBasementWet19542001
1426VOQVictaulicBasementDry19542001
1427VOQVictaulicBasementWet19542000
1435SC Info.System & ComputerVictaulicMech RoomWet19592009
1435SC Info.System & ComputerANSUL NOVEC 1230Server RoomANSUL1959
1445SF WarehouseVictaulicSouth East Corner of Build.Wet20062005
1510DormVictaulicStairwellWet/STD19552001
1511DormVictaulicStairwellWet/STD19552001
1531UNDER CONSTRUCTION19652016
1538TheaterunknownMech RoomWet19562001
1548Fitness CenterTyco 6”Mech RoomWet19562006
1600Elect. Rsch EngRascoRoom 117 ClosetWet19551990
1603ChapelWet19552016
1604PK/JAPorter/VictaulicMech RoomWet20102009
1607Elect. Rsch EngVictaulicBasement Mech RoomWet/STD19552000
1608Auto Hobby ShopReliableGarageWet19781999
1612Elect Rsch EngAutomatic1st Floor Mech RoomWet/STD19811980
1614Phase IRascoMech RoomWet19552001
1614Phase IIReliableLoading DockWet19552001
1614Phase 0ReliableNear Room 148Wet19552001
1618Admin OfficeVictaulicWet19642014
1624Elect. Rsch EngFirematicMech RoomWet/STD19872008
1630Elect. Rsch EngFirematicMech RoomWet/STD19901987
1642Motor PoolCSCNorth Side (@pumps)Wet19551954
1642Motor PoolCSCSouth SideWet19551954
1646DMATSANSUL IQ318/VESDA1st floor/basementANSUL1953
1709BX AAFESReliableZone A – Sprink RoomWet20022001
1709BX AAFESReliableZone B – Sprink RoomWet20022001
1725Security ForcesVikingMech RoomWet19951994
1728Education CenterZasco 4”Hall ClosetWet19551996
1813BE Storage ShedVikingMech RoomWet19522002
1813BE Storage ShedVikingMech RoomDry19522004
1827CE Roads & GroundsVictaulicMech RoomWet20072007
1993Youth CenterPorterMech RoomWet19732004
1994Child Care CenterFirematicMech RoomWet19941994
1999After School CareReliableMech RoomDry19602001
Sagamore HillSagamore HillIQ301 BFA, VESDA & INERGENBlgs 5 & 6ANSUL ANSUL1968 & 1990
10 Stand Pipe
44 Wet
6 Dry
8 Clean Agent
3 Fire Pump

File details come from the government source that posted it. Updated .