Exhibit_J-_Architectural_Plans.pdf
PDF 7 MB Posted
- Attached to
- Daytona Beach Ocean Center Kitchen Renovation
- Solicitation number
- 26-P-126JD, C2096
- Issued by
- Volusia County, Florida
About this file
This architectural plans document is for the Daytona Beach Ocean Center, a commercial kitchen renovation project located at 101 N. Atlantic Avenue in Daytona Beach, Florida 32118. The project scope encompasses a complete kitchen renovation classified as a Level 1 Alteration under the Florida Building Code. Key deliverables include mechanical removal of approximately 5,210 square feet of existing quarry tile flooring with integral cove base, substrate preparation via shot blasting and diamond grinding, and installation of a urethane cement flooring system with 720 linear feet of integral cove base. The flooring system is specified to replicate installations completed in two Volusia County Jail projects, utilizing DUR-A-FLEX products including a poly-crete MDB body coat and pigmented urethane cement topcoat. The project incorporates comprehensive plumbing, mechanical, fuel gas, and accessibility systems designed to meet Florida Building Code 7th Edition 2020 standards, with design specifications including 140 MPH basic windspeed, Type II-B (Sprinklered) construction classification, and Risk Category II occupancy for Business Group B use.
The architectural plans establish detailed construction requirements and compliance standards, including submission of reports and data signed by a licensed Florida structural engineer documenting component and cladding compliance with Florida Building Code provisions. All work must be executed in accordance with governing national, state, and local codes and regulations, including the Florida Fire Prevention Code 7th Edition 2020 and National Electric Code 2017. The document emphasizes contractor responsibility for site dimension verification prior to work commencement and establishes the architect as the authority for resolving conflicts between documents, with the most stringent condition applying if conflicts are not reported. The project is designated for permitting purposes only and protected under copyright law, with authentication through the architect, Rolando Sosa, AIA, FL License AR96264, located in Ocala, Florida.
View the file
Other files
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
101 N. ATLANTIC AVENUE
OCEAN CENTER
A NEW KITCHEN RENOVATION PROJECT FOR:
DAYTONA BEACH , FLORIDA 32118
BUILDING DATA: INDEX OF DRAWINGS
COMPONENT & CLADDING DESIGN PRESSURE
LOADS: SUPPLIERS / MANUFACTURERS OF ALL
CLADDING AND COMPONENTS ( INCLUDING, BUT
NOT LIMITED TO: SIDING, ROOFING, DOORS,
WINDOWS, AWNINGS, ETC. ) WILL SUBMIT REPORTS
& DATA SIGNED AND SEALED BY A LICENSED
STRUCTURAL ENGINEER IN THE STATE OF FLORIDA
DOCUMENTING COMPLIANCE WITH THIS PROVISION
OF THE FLORIDA BUILDING CODE; 2020 EDITION.
APPLICABLE INTERNAL PRESSURE COEFFICIENT:
0.18 FOR ENCLOSED STRUCTURES AND 0.55 FOR
COVERED ENTRIES.
BASIC WINDSPEED: 140 MPH
WIND IMPORTANCE FACTOR : 1
WIND EXPOSURE: B
WIND LOADING CRITERIA:
A= 3'-6"
FBC TABLE 1609.3(1)
ARCHITECTURE LOCATION PLAN
CODE REFERENCE
APPLICABLE CODES:
THIS PROJECT IS DESIGNED TO MEET THE REQUIREMENTS OF:
FLORIDA BUILDING CODE (FBC) 7TH EDITION 2020: BUILDING
FLORIDA BUILDING CODE (FBC) 7TH EDITION 2020: PLUMBING
FLORIDA BUILDING CODE (FBC) 7TH EDITION 2020: MECHANICAL
FLORIDA BUILDING CODE (FBC) 7TH EDITION 2020: FUEL GAS
FLORIDA BUILDING CODE (FBC) 7TH EDITION 2020: ACCESSIBILITY
FLORIDA BUILDING CODE (FBC) 7TH EDITION 2020: EXISTING BUILDING
FLORIDA BUILDING CODE (FBC) 7TH EDITION 2020: ENERGY CONSERVATION CODE
FLORIDA FIRE PREVENTION CODE 7TH EDITION 2020
NATIONAL ELECTRIC CODE 2017
TYPE OF CONSTRUCTION (FBC CHAPTER 6):
TYPE II-B (SPRINKLERED)
RISK CATEGORY (FBC CHAPTER 16 TABLE 1604.5):
RISK CATEGORY: II
PRIMARY OCCUPANCY (FBC CHAPTER 3):
BUSINESS - GROUP B
GENERAL NOTES
ALL WORK SHALL BE EXECUTED IN ACCORDANCE WITH ALL GOVERNING NATIONAL,
STATE AND LOCAL CODES AND REGULATIONS.
ALTHOUGH EVERY EFFORT HAVE BEEN MADE TO PROVIDE CLEAR AND CONCISE
DOCUMENTS, ANY CONFLICTS FOUND SHALL BE BROUGHT TO THE ATTENTION OF THE
ARCHITECT FOR HIS CLARIFICATION OR DETERMINATION OF WHICH CONDITION
(MATERIAL / CALLOUTS/ OR DETAILS) SHALL GOVERN. IF THE ARCHITECT IS NOT
NOTIFIED OF CONFLICTS THEN THE MOST STRINGENT WILL BE USED AS DETERMINED
BY THE ARCHITECT.
ALL BUILDING ELEMENTS SHALL BE INSTALLED STRAIGHT, LEVEL, PLUMB AND
SQUARE.
DUE TO MATERIAL TOLERANCES THE GENERAL CONTRACTOR MUST VERIFY ALL
DIMENSIONS WITH ACTUAL CONDITIONS ON THE SITE AND REPORT ANY DIFFERENCES
TO THE ARCHITECT FOR INTERPRETATION AND RESOLUTION PRIOR TO
COMMENCEMENT OF WORK.
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
A000
LOCATION PLAN
N O R
TH
SCALE: 1/16' = 1'-0"
A000 COVER, PROJECT INFORMATION
ARCHITECTURAL
DEMOLITION PLAN A100
PLUMBING
P001 PLUMBING SYMBOLS, LEGEND, NOTES, SCHEDULES AND INDEX
P002
P101 sheet no.
project no.
by date 03.24.23 project no.
by date
SG
BID DOCUMENTS
A N
EW
K
IT
CH
EN
R
EN
O
VA
TI
O N
F O
R:
O
CE
A N
C
EN
TE
R
D A
YT
O
N A
B
EA
CH
, F
LO
RI
D A co py rig ht
RO
LA
N
DO
S O
SA
, A
RC
HI
TE
CT
FL
L
IC
EN
SE
: A
R
Th is el ec tr on ic al ly si gn ed a nd se al ed d oc um en t i s o nl y va lid fo r a o ne ti m e us e of th is pr oj ec t i n on e lo ca tio n fo r pe rm itt in g.
C op ie s o f t hi s d oc um en t a re n ot c on sid er ed sig ne d an d se al ed
. A ut he nt ic at io n co de a nd si gn at ur e m us t b e ve rif ie d.
w w w .s os ar ch ite ct .c om so sa so sa rc hi te ct
.c om e as t f or t k in g st su ite
. O ca la , f l.
p:
(3
) 6
-0 flo rid a lic en se aa
N . A
TL
A
N
TI
C A
V
EN
U E
CV-1 COVER
P200
P300 PLUMBING RISERS
P400 PLUMBING DETAILS
PD100 ENLARGED KITCHEN PLUMBING FLOOR PLAN DEMOLITION
ENLARGED KITCHEN PLUMBING FLOOR PLAN RENOVATION
PLUMBING OVERALL FLOOR PLAN RENOVATION
PLUMBING SPECIFICATIONS
CLASSIFICATION OF WORK (FBC CHAPTER 6 SECTION 602):
ALTERATION : LEVEL 1
FLOOR PLAN A200
LOCATION
OF WORK
AutoCAD SHX Text ALL RIGHTS RESERVED, THESE PLANS ARE PROTECTED BY COPYRIGHT LAWS. UNAUTHORIZED USE MAY RESULT IN LEGAL ACTION.
AutoCAD SHX Text C
AutoCAD SHX Text
NORTH
D
C
B
A
C.7
C.2
C.8
E
D.3
D
EXISTING PRODUCT COOLER
NOT IN CONTRACT
EXISTING PRODUCT FREEZER
NOT IN CONTRACT
sheet no.
project no.
by date 03.24.23 project no.
by date
SG
BID DOCUMENTS
A N
EW
K
IT
CH
EN
R
EN
O
VA
TI
O N
F O
R:
O
CE
A N
C
EN
TE
R
D A
YT
O
N A
B
EA
CH
, F
LO
RI
D A co py
RO
LA
N
DO
S O
SA
, A
RC
HI
TE
CT
FL
L
IC
EN
SE
: A
R
Th is el ec tr on ic al ly si gn ed a nd se al ed d oc um en t i s o nl y va lid fo r a o ne ti m e us e of th is pr oj ec t i n on e lo ca tio n fo r pe rm itt in g.
C op ie s o f t hi s d oc um en t a re n ot c on sid er ed sig ne d an d se al ed
. A ut he nt ic at io n co de a nd si gn at ur e m us t b e ve rif ie d.
w w w .s os ar ch ite ct .c om so sa so sa rc hi te ct
.c om e as t f or t k in g st su ite
. O ca la , f l.
p:
(3
) 6
-0 flo rid a lic en se aa
N . A
TL
A
N
TI
C A
V
EN
U E
SCALE: 1/8" = 1'-0"
DEMOLITION PLAN
EXISTING DRAIN (SITE VERIFY)
FLOOR PLAN LEGEND
EXISTING TO REMAIN
SCOPE OF DEMOLITION WORK:
1. MECHANICALLY REMOVE EXISTING QUARRY TILE AND INTEGRAL COVE BASE.
2. MECHANICALLY REMOVE TILE, THINSET, VIA INDUSTRIAL GRINDERS.
3. MECHANICALLY PREPARE SUBSTRATE VIA SHOT BLASTING/DIAMOND GRINDING.
4. PREPARE/REPAIR STANDARD JOINTS, CRACKS AND DIVOTS.
5. EXISTING DRAINS TO BE SITE FIELD VERIFY
6. FOR PLUMBING AND EQUIPMENT SEE ENGINEER DRAWINGS.
EXISTING TILE SYSTEM TO BE REMOVE
( SEE DEMOLITION NOTE)
A100
EXISTING
NOT IN CONTRACT
EXISTING
NOT IN CONTRACT
ED
ED ED ED ED
ED
ED
ED
EDEDED
ED
ED
ED
ED
ED
EDED
EXISTING CONDITIONS
AutoCAD SHX Text ALL RIGHTS RESERVED, THESE PLANS ARE PROTECTED BY COPYRIGHT LAWS. UNAUTHORIZED USE MAY RESULT IN LEGAL ACTION.
D
B
A
C.7
C.2
C.8
E
D.3
D
V E R
IF
Y
1"
V
E R
IF
Y 79'-4" ± VERIFY
36'-11" ± VERIFY
sheet no.
project no.
by date 03.24.23 project no.
by date
SG
BID DOCUMENTS
A N
EW
K
IT
CH
EN
R
EN
O
VA
TI
O N
F O
R:
O
CE
A N
C
EN
TE
R
D A
YT
O
N A
B
EA
CH
, F
LO
RI
D A co py
RO
LA
N
DO
S O
SA
, A
RC
HI
TE
CT
FL
L
IC
EN
SE
: A
R
Th is el ec tr on ic al ly si gn ed a nd se al ed d oc um en t i s o nl y va lid fo r a o ne ti m e us e of th is pr oj ec t i n on e lo ca tio n fo r pe rm itt in g.
C op ie s o f t hi s d oc um en t a re n ot c on sid er ed sig ne d an d se al ed
. A ut he nt ic at io n co de a nd si gn at ur e m us t b e ve rif ie d.
w w w .s os ar ch ite ct .c om so sa so sa rc hi te ct
.c om e as t f or t k in g st su ite
. O ca la , f l.
p:
(3
) 6
-0 flo rid a lic en se aa
N . A
TL
A
N
TI
C A
V
EN
U E
SCALE: 1/8" = 1'-0"
FLOOR PLAN
FLOOR PLAN LEGEND
- EPOXY FLOORING BY 'DUR-A-FLEX'
EXISTING TO REMAIN
NEW FLOOR SYSTEM AREA
EXISTING PRODUCT COOLER
NOT IN CONTRACT
EXISTING PRODUCT FREEZER
NOT IN CONTRACT
SCOPE OF WORK:
PROVIDE & INSTALL URETHANE CEMENT FLOORING SYSTEM (APPX 5,210SF) WITH CORRESPONDING INTEGRAL COVE BASE (APPX 720LF/6"). SEE ATTACHED COLOR-CODED FLOOR PLAN TO VERIFY INSTALLATION AREAS. THIS WILL BE A REPLICATION OF THE SYSTEM
INSTALLED IN THE TWO VOLUSIA COUNTY JAIL PROJECTS.
1. MECHANICALLY REMOVE EXISTING QUARRY TILE AND INTEGRAL COVE BASE.
2. MECHANICALLY REMOVE TILE, THINSET, VIA INDUSTRIAL GRINDERS.
3. MECHANICALLY PREPARE SUBSTRATE VIA SHOT BLASTING/DIAMOND GRINDING.
4. PREPARE/REPAIR STANDARD JOINTS, CRACKS AND DIVOTS.
5. DELIVER INTEGRAL COVE BASE, 6", TO FLOOR WALL UNIONS WITHIN INSTALLATION AREAS.
6. APPLY URETHANE CEMENT BODY COAT, 1/4" (DUR-A-FLEX, POLY-CRETE MDB) AND BROADCAST NATURAL AGGREGATE TO REJECTION.
7. APPLY PIGMENTED, URETHANE CEMENT TOPCOAT (DUR-A-FLEX, TF+) TO FLOORING AND INTEGRAL COVE BASE.
8. EXISTING DRAINS TO BE SITE FIELD VERIFY
A200
EXISTING
NOT IN CONTRACT
EXISTING
NOT IN CONTRACT
AutoCAD SHX Text ALL RIGHTS RESERVED, THESE PLANS ARE PROTECTED BY COPYRIGHT LAWS. UNAUTHORIZED USE MAY RESULT IN LEGAL ACTION.
| SS_A000_2337_COVERSHEET.pdf |
| Sheets and Views |
| A000_XXXX |
| SS_A100_2337_DEMOLITION_PLAN.pdf |
| Sheets and Views |
| A100 |
| SS_A200_2337_FLOOR_PLAN_NOTES_(003).pdf |
| Sheets and Views |
| A200 |
File details come from the government source that posted it. Updated .