Exhibit H - Inspection Report Bavak B-Secure Speedgates.pdf

PDF 760 KB Posted

Attached to
Maintenance Services of Barriers and Gates
Solicitation number
191T7026R0001
Issued by

About this file

This is an inspection report template for Bavak B-Secure Speedgate 2.0 security gate installations. The form is designed to document comprehensive field inspections of automated security gate systems and is provided by Bavak Beveiligingsgroep B.V., a Netherlands-based security company located in Noordwijk.

The inspection report captures site information including name, address, location, contact person, phone number, and installation details such as serial numbers for both the Speedgate system and control components. The report systematically evaluates 36 inspection items covering mechanical, electrical, and safety components including motor operation and clearances, drive unit elements, manual release mechanisms, encoders, panel hinges and bearings, guide wheels and brackets, end limit stops, brushes and draft strips, gate and cabinet locks, steel plating, drainage systems, cabling infrastructure, photoelectric beams, safety buffers and edges, detection loops, induction loop detectors, electrical components and signals, PLC and PCB programming, traffic lights, pavement levels, powder coating condition, software status, type plates and warning signals, operational sequencing tests, cleaning status, and logbook maintenance. Each inspection item includes four evaluation categories: "Not applicable," "All right/Correct," "Needs attention," and "Not all right." The form concludes with space for technician remarks, comments section, and signature lines for both the Bavak engineer and site responsible party. This template serves as a standardized quality assurance and maintenance documentation tool for security gate system inspections.

View the file

Other files

File Type Posted
Questions and Answers.pdf PDF
Conference Minutes.pdf PDF
Exhibit G - Checklist Bavak B-Secure Speedgates.pdf PDF
Exhibit A - Pricing Schedule.xlsx XLSX spreadsheet
Exhibit I - Oil Datasheet Arnica S46.pdf PDF
Prospective Offerors Cover Letter.pdf PDF
SF-1442.pdf PDF
191T7026R0001.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

INSPECTION REPORT

Site Name: Tested / checked by (name technician):

Address: Inspection date:

Zipcode / City: Inspection times(start-end):

Country: Type of installation:

Contact person on site: Type Controls:

Phone: Serial no. SG:

Serial no. Controls:

Type of installation Speedgate B-secure 2.0

* Delete whichever is not applicable

** When a detection loop has been declared unfit, please indicate function, measured value and type of paving.

Remarks:

1) Motor (clearances, measurement, operation)

2) Drive unit (All drive elements)

3) Manual release

4) Encoder

5) Panel hinges (operation, wear)

6) Bearings of panel hinges

7) Movement of the panels (visible)

8) End limit stop (Gearwheel blocking mechanism)

9) Guide wheels (wear)

10) Guide wheel brackets ( Fastening / axle / locknut)

11) Bearing top side column

12) Bearing bottom side column

13) Check all mechanical connections

14) Brushes / draft strips (option)

15) Locks gate and control cabinet (functionality )

16) Steel plate on gate panels

17) Inspection hatches

18) Drainage of drive unit gate

19) Cabling in drive unit

20) Photo electric beams (working, attachment)

21) Safety buffers/edges (working, wear (hor./vert.)

22) Detection loops (working, measurements)**

23) Induction loop detector

24) Electrical components (working)

25) Electrical signals

26) PLC-progamming / PCB Programming

27) Cabling from junctionbox / motorswitch to cabinet

28) Traffic lights (working, overall condition)

29) Pavement level (in relation to install., detec. loops)

30) Measurements

31) Powder coating / damage

32) PLC / PCB software

33) Type plate & warning signals (applied &visible)

34) Sequence of operation test (app. 5 minutes)

35) Cleaning

35) Logbook present & filled in

Comments:

Name and Signature Bavak engineer: Name and Signature site responsible:

N o t ap p lic ab le

A ll ri gh t/ C o rr ec t

N ee d s at te n ti o n

N o t al l r ig h t

Bavak Beveiligingsgroep B.V.

P.O. Box 334 - 2200 AH Noordwijk

Zwarteweg 19 - 2201 AA Noordwijk The Netherlands

Ph: +31(0)714035544 internet:www.bavak.com

Service:

Phone: +31 71 4025020

R_012025

Exhibit H - Inspection Report Bavak B-Secure Speedgates