Exhibit H - Equipment Cutsheet - AC-273A_273B.pdf
PDF 130 KB Posted
- Solicitation number
- RFP-2023-23044
- Issued by
-
Department of Energy Office of Science
View the file
Other files
Show all 22
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MODEL SN5507S SN5509S
Full Load Pressure - psig 100 125
Capacity at Full Load Pressure - acfm 387 354
Power at Full Load Pressure - bhp 84.8 85.1
Package kW Air-Cooled 68.3 68.5
Package kW Water-Cooled 66.9 67.0
Gear Ratio 1.33 1.22
Fluid Flow - gpm 19.0 17.0
Heat Rejection - Fluid Clr. BTU/min. 2893 2937
Heat Rejection - Aft. Clr. BTU/min. 705 636
Flow at 80°F Water in - gpm 19.0 19.0
Pipe connection NPT In/Out - in. 1 1/2 / 1 1/2 1 1/2 / 1 1/2
Max./Min. Water Pressure - psig 75/25 75/25
Water Outlet Temperature F° 110 110
Air Flow Water-Cooled Fan w/encl. - cfm 2845 2845
Water-Cooled Vent Fan - hp 1/4 1/4
Air Flow Air-Cooled Fan - cfm 6000 6000
Air-Cooled Fan Motor - hp 2.0 2.0
Air-Cooled Fan Motor Nominal Efficiency 88.5% 88.5%
Standard Fan Water Column - in. 1/8 1/8
High Static Fan Water Column - in. 3/4 3/4
Fluid Fill Capacity - U.S. Gal. 5.0 5.0
Volume - Cubic Feet Air (U.S. Gal.) 3.1 (23) 3.1 (23)
Rated Pressure - psig 210 210
Air-Cooled w/enclosure 70 70
Water-Cooled w/enclosure
Inlet Air
Main Lubricant Flow Beta
99.9% Eff. To 3 Microns Per SAE J726C
Beta 20 = 200 Per ISO 16889
SN55S Series - 75 HP 60 Hz Horsepower Rated
Compressor Performance*
Cooling Data
Water-Cooled Series Flow (w/aftercooler)
Cooling Air Flows
Air/Fluid Housing dBA Ratings at 1 Meter (Typical)
CONSULT FACTORY
Filter Rating
For more information, contact Sullair at
219.879.5451 or sullairsolutions@sullair.com www.sullair.com
Sullair Proprietary and Confidential
© 2017 Sullair etankersley Rectangle jkomperud Cloud
Length - in. 87.6 (97.0) 87.6 (97.0)
Width - in. 43.4 (49.9) 43.4 (49.9)
Height - in. 68.5 (77.2) 68.5 (77.2)
Weight - lbs. 3455 (3785) 3455 (3785)
Discharge Connection - in. NPT 2 2
Moisture Drain Connection - in. NPT 1/4 1/4
Electrical Data (Typical across all models) 230V 460V 575V
Motor HP 75 75 75
Motor Nominal Efficiency 95.0% 95.0% 95.0%
Nominal RPM 1780 1780 1780
Frame Size (TEFC) 364/5TSC 364/5TSC 364/5TSC
Service Factor 1.2 1.2 1.2
Nameplate Amps 168.0 84.1 65.8
Locked Rotor Amps - Max. 1076 538 480
Starter Enclosure Rating NEMA 4 NEMA 4 NEMA 4
Starter Size Amp Rating 300 115 115
Fan Amps (Air Cooled) 6.45 3.23 2.58
Package Amps (Air Cooled) 197.3 98.7 78.9
Package Amps (Water Cooled) 193.3 96.8 77.3
NOTE: Data subject to change without notice
TC Doc #: TDS-000346/00
Dimensions & Weights w/Enclosure - Uncrated (Crated)
* Capacity per CAGI/PNEUROP PN2CPTC2 (Annex C to ISO 1217)
For more information, contact Sullair at
219.879.5451 or sullairsolutions@sullair.com www.sullair.com
Sullair Proprietary and Confidential
© 2017 Sullair
File details come from the government source that posted it. Updated .