This is a construction plans document prepared by AVCON Engineers & Planners for the County of Volusia, Florida, in support of the Daytona Beach International Airport Taxiway P3 and P4 Improvements project. The construction plans consist of 60 sheets of detailed engineering drawings, specifications, and construction details for the rehabilitation and widening of Taxiway P3 and P4, including associated taxiway P connector improvements. The project scope includes demolition of existing asphalt pavement, grading and drainage work, new flexible pavement construction with asphalt surface and leveling courses totaling 4,840 tons, pavement markings covering 25,200 to 28,500 square feet, complete replacement of airfield lighting systems with new FAA-rated fixtures and circuiting, installation of taxiway and runway edge lights, runway guard lights, and directional signage, drainage infrastructure including corrugated metal pipes and concrete inlets, sodding of approximately 27,600 square yards, and electrical work encompassing 27,500 linear feet of cable installation and 8,350 linear feet of PVC duct banks. The construction plans document was electronically signed and sealed on February 18, 2026, and includes detailed sheets covering survey control, existing conditions, demolition plans, geometry and paving plans, grading and drainage, construction details, pavement markings, airfield electrical systems including lighting layout, circuiting diagrams, fixture installation details, sign schedules and details, manhole specifications, conduit and duct bank configurations, wiring details, lightning arrestor assemblies, and temporary airfield lighting provisions.
The plans incorporate comprehensive construction safety and phasing plans addressing contractor storage, staging areas, haul routes, dust control, security requirements, dewatering, and erosion control measures. Specific design elements shown throughout the plans address FAA compliance with Advisory Circular 150/5300-13B standards, including taxiway geometry points, cross-sections, and profile elevations. The electrical plans detail 68 taxiway edge lights and associated runway guard lights, with comprehensive circuiting and fixture numbering systems utilizing L-867 and L-868 base cans in various configurations for both semiflush and elevated installations. Construction details address mill and overlay fixture preparation procedures, sign mounting and installation methods, junction can plaza configurations, conduit protection criteria, cable tagging and connector specifications, lightning arrestor field assembly, and temporary taxiway and runway edge light provisions. The project documents indicate multiple construction phases with detailed coordination between civil, drainage, and electrical work, requiring contractor compliance with all FAA and Federal Transit Administration regulations applicable to Airport Improvement Program funding.
View the file
Other files
Show all 21
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
T
AC
AC
WV
PROJECT AREA
North
DAYTONA BEACH INTERNATIONAL AIRPORT
DAYTONA BEACH, FLORIDA
TAXIWAY P3 AND P4 IMPROVEMENTS
PROJECT MAP
N.T.S.
MIAMI
PANAMA CITY
PENSACOLA
JACKSONVILLE
ORLANDO
TAMPA
TALLAHASSEE
FT.PIERCE
TITUSVILLE
VICINITY MAP
N.T.S.
VOLUSIA COUNTY
This item has been electronically signed and sealed by SEAL on 2/18/2026 using an SHA-1 authentication code. Printed copies of this document are not considered signed and sealed and the SHA-1 authentication code must be verified on any electronic copies.
CIVIL DRAINAGE
This item has been electronically signed and sealed by ############################ on 2/18/2026 using an SHA-1 authentication code. Printed copies of this document are not considered signed and sealed and the SHA-1 authentication code must be verified on any electronic copies.
ENGINEERS & PLANNERS
5555 E. MICHIGAN ST., SUITE 200 - ORLANDO, FL
32822-2779 OFFICE: (407) 599-1122 - FAX: (407) 599-1133
CORPORATE CERTIFICATE OF AUTHORIZATION
NUMBER: 5057 www.avconinc.com
DAYTONA
BEACH
PLANS PREPARED BY:
North
XXXX
XXXX
2024.199.05
FEBRUARY 2026DATE
AVCON PROJECT NO.
FDOT FM NO.
FAA AIP NO.
DESCRIPTIONDATENO.
R E V I S I O N S
BID DOCUMENTS
ELECTRICAL
This item has been electronically signed and sealed by SEAL2 on 2/18/2026 using an SHA-1 authentication code. Printed copies of this document are not considered signed and sealed and the SHA-1 authentication code must be verified on any electronic copies.
PROFESSIONAL SEALS
DAYTONA BEACH
INTERNATIONAL
AIRPORT
LOCATION
OF PROJECT
2024.199.05
DRAWING
FEBRUARY 2026
SS
NO. DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
REVISIONS:
TW P3 AND TW P4
IMPROVEMENTS
DAYTONA BEACH
INTERNATIONAL
AIRPORT
2419905002G002CADD
PROFESSIONAL SEAL
FDOT FM:
FAA AIP: XXXX
XXXX
ENGINEERS & PLANNERS
5555 E. MICHIGAN ST., SUITE 200 - ORLANDO, FL 32822-2779
OFFICE: (407) 599-1122 - FAX: (407) 599-1133 CORPORATE
CERTIFICATE OF AUTHORIZATION NUMBER: 5057
www.avconinc.com
AVCON PROJECT NO.
SHEET OF 60
B
ID
D O
C U
M
EN
TS
This item has been electronically signed and sealed by using an SHA-1 authentication code. Printed copies of this document are not considered signed and sealed and the SHA-1 authentication code must be verified on any electronic copies.
INDEX OF
DRAWINGS
RDH
UO
RKH
G002
SEAL on 2/18/2026
INDEX OF DRAWINGS
SHT
NO.
DWG
NO. TITLE
FEBRUARY 2026
SS
NO. DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
REVISIONS:
TW P3 AND TW P4
IMPROVEMENTS
DAYTONA BEACH
INTERNATIONAL
AIRPORT
2419905003G003CADD
PROFESSIONAL SEAL
FDOT FM:
FAA AIP: XXXX
XXXX
ENGINEERS & PLANNERS
5555 E. MICHIGAN ST., SUITE 200 - ORLANDO, FL 32822-2779
OFFICE: (407) 599-1122 - FAX: (407) 599-1133 CORPORATE
CERTIFICATE OF AUTHORIZATION NUMBER: 5057
www.avconinc.com
AVCON PROJECT NO.
SHEET OF 60
B
ID
D O
C U
M
EN
TS
GENERAL CONSTRUCTION NOTES
UTILITY ALERT
This item has been electronically signed and sealed by using an SHA-1 authentication code. Printed copies of this document are not considered signed and sealed and the SHA-1 authentication code must be verified on any electronic copies.
GENERAL
CONSTRUCTION
NOTES AND
DETAILS
RDH
UO
RKH
G003
SEAL on 2/18/2026
ST
ST ST
CONSTRUCT TW P3, TW P4, AND
TW P IMPROVEMENTS
TAXIWAY P
TA
XI
W A
Y P4
TA
XI
W A
Y P3
RUNWAY 7L-25R
1733+00.00 1734+00.00 1735+00.00 1736+00.00 1737+00.00 1738+00.00 1739+00.00 1740+00.00 1741+00.00 1742+00.00 1743+00.00 1744+00.00 1745+00.00 1746+00.00 1747+00.00 1748+00.00 1749+00.00
+0 0.
+0
0.
+0 0.
+0
0.
1904+00.00
1905+00.00 1906+00.00 1907+00.00 1908+00.00 1909+00.00 1910+00.00 1911+00.00 1912+00.00 1913+00.00 1914+00.00 1915+00.00 1916+00.00 1917+00.00
+0 0.
2001+00.00
+0 0.
+0
0.
2004+00.00
2004+50.00
2024.199.05
DRAWING
FEBRUARY 2026
SS
NO. DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
REVISIONS:
TW P3 AND TW P4
IMPROVEMENTS
DAYTONA BEACH
INTERNATIONAL
AIRPORT
2419905004G004CADD
PROFESSIONAL SEAL
FDOT FM:
FAA AIP: XXXX
XXXX
ENGINEERS & PLANNERS
5555 E. MICHIGAN ST., SUITE 200 - ORLANDO, FL 32822-2779
OFFICE: (407) 599-1122 - FAX: (407) 599-1133 CORPORATE
CERTIFICATE OF AUTHORIZATION NUMBER: 5057
www.avconinc.com
AVCON PROJECT NO.
SHEET OF 60
B
ID
D O
C U
M
EN
TS
GRAPHIC SCALE (FT)
1206030
NORTH
This item has been electronically signed and sealed by using an SHA-1 authentication code. Printed copies of this document are not considered signed and sealed and the SHA-1 authentication code must be verified on any electronic copies.
GENERAL SITE PLAN
RDH
UO
RKH
G004
ST
ST ST
ST
ST
ST
ST
T
AC
AC
WV
RUNWAY 7L-25R
TAXIWAY P
TA
XI
W A
Y P4
TA
XI
W A
Y B
TA
XI
W A
Y B
TAXIWAY N
TA
XI
W A
Y N
TA
XI
W A
Y N
TA
XI
W A
Y N
TA
XI
W A
Y N
TA
XI
W A
Y N
TA
XI
W A
Y P5
BELLEVUE AVE
BELLEVUE AVE
TA
XI
W A
Y P3
2024.199.05
DRAWING
FEBRUARY 2026
SS
NO. DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
REVISIONS:
TW P3 AND TW P4
IMPROVEMENTS
DAYTONA BEACH
INTERNATIONAL
AIRPORT
2419905005G100CADD
PROFESSIONAL SEAL
FDOT FM:
FAA AIP: XXXX
XXXX
ENGINEERS & PLANNERS
5555 E. MICHIGAN ST., SUITE 200 - ORLANDO, FL 32822-2779
OFFICE: (407) 599-1122 - FAX: (407) 599-1133 CORPORATE
CERTIFICATE OF AUTHORIZATION NUMBER: 5057
www.avconinc.com
AVCON PROJECT NO.
SHEET OF 60
B
ID
D O
C U
M
EN
TS
GRAPHIC SCALE (FT)
400200100
NORTH
PROJECT SCHEDULE AND SEQUENCE LEGEND PHASING NOTES HAUL ROUTE NOTE
This item has been electronically signed and sealed by using an SHA-1 authentication code. Printed copies of this document are not considered signed and sealed and the SHA-1 authentication code must be verified on any electronic copies.
CONSTRUCTION
SAFETY AND
PHASING PLAN
RDH
UO
RKH
G100
LIGHTED RUNWAY CLOSURE MARKER NOTES
AVIATION FLAG
FAA L-893 LIGHTED RUNWAY CLOSURE MARKER
LOW-PROFILE BARRICADE NOTES
LOW-PROFILE BARRICADE
HIGHWAY
ENTERING
TRUCKS
TRUCKS ENTERING HIGHWAY SIGN TRAFFIC CONE
SAFETY PLAN
2024.199.05
DRAWING
FEBRUARY 2026
SS
NO. DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
REVISIONS:
TW P3 AND TW P4
IMPROVEMENTS
DAYTONA BEACH
INTERNATIONAL
AIRPORT
2419905006G110-G112CADD
PROFESSIONAL SEAL
FDOT FM:
FAA AIP: XXXX
XXXX
ENGINEERS & PLANNERS
5555 E. MICHIGAN ST., SUITE 200 - ORLANDO, FL 32822-2779
OFFICE: (407) 599-1122 - FAX: (407) 599-1133 CORPORATE
CERTIFICATE OF AUTHORIZATION NUMBER: 5057
www.avconinc.com
AVCON PROJECT NO.
SHEET OF 60
B
ID
D O
C U
M
EN
TS
This item has been electronically signed and sealed by using an SHA-1 authentication code. Printed copies of this document are not considered signed and sealed and the SHA-1 authentication code must be verified on any electronic copies.
CONSTRUCTION
SAFETY AND
PHASING NOTES
AND DETAILS
(SHEET 1 OF 3)
RDH
UO
RKH
G110
SEAL on 3/28/2025
CONSTRUCTION
AHEAD
CONSTRUCTION
AHEAD
CONSTRUCTION AHEAD SIGN (FROM AC 150/5370-2G)
SIGN MOUNTING DETAIL
CONSTRUCTION
HAUL
ROUTE
CONSTRUCTION HAUL ROUTE SIGN
SAFETY AREA STANDARDS - TEMPORARY CONDITIONS DURING CONSTRUCTION
SAFETY AREA NOTES
TAXIWAY CLOSURE MARKER DETAIL
CONSTRUCTION AHEAD SIGN NOTES CONSTRUCTION HAUL ROUTE SIGN NOTES
2024.199.05
DRAWING
FEBRUARY 2026
SS
NO. DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
REVISIONS:
TW P3 AND TW P4
IMPROVEMENTS
DAYTONA BEACH
INTERNATIONAL
AIRPORT
2419905006G110-G112CADD
PROFESSIONAL SEAL
FDOT FM:
FAA AIP: XXXX
XXXX
ENGINEERS & PLANNERS
5555 E. MICHIGAN ST., SUITE 200 - ORLANDO, FL 32822-2779
OFFICE: (407) 599-1122 - FAX: (407) 599-1133 CORPORATE
CERTIFICATE OF AUTHORIZATION NUMBER: 5057
www.avconinc.com
AVCON PROJECT NO.
SHEET OF 60
B
ID
D O
C U
M
EN
TS
This item has been electronically signed and sealed by using an SHA-1 authentication code. Printed copies of this document are not considered signed and sealed and the SHA-1 authentication code must be verified on any electronic copies.
CONSTRUCTION
SAFETY AND
PHASING NOTES
AND DETAILS
(SHEET 2 OF 3)
RDH
UO
RKH
G111
CONTRACTOR STORAGE, STAGING, HAUL ROADS, AND DUST CONTROL GENERAL SITE AND SAFETY NOTES
ADDITIONAL OPERATIONS AND SAFETY NOTES
SECURITY NOTES
2024.199.05
DRAWING
FEBRUARY 2026
SS
NO. DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
REVISIONS:
TW P3 AND TW P4
IMPROVEMENTS
DAYTONA BEACH
INTERNATIONAL
AIRPORT
2419905006G110-G112CADD
PROFESSIONAL SEAL
FDOT FM:
FAA AIP: XXXX
XXXX
ENGINEERS & PLANNERS
5555 E. MICHIGAN ST., SUITE 200 - ORLANDO, FL 32822-2779
OFFICE: (407) 599-1122 - FAX: (407) 599-1133 CORPORATE
CERTIFICATE OF AUTHORIZATION NUMBER: 5057
www.avconinc.com
AVCON PROJECT NO.
SHEET OF 60
B
ID
D O
C U
M
EN
TS
This item has been electronically signed and sealed by using an SHA-1 authentication code. Printed copies of this document are not considered signed and sealed and the SHA-1 authentication code must be verified on any electronic copies.
CONSTRUCTION
SAFETY AND
PHASING NOTES
AND DETAILS
(SHEET 3 OF 3)
RDH
UO
RKH
G112
SEAL on 8/29/2025
AC
WV
2024.199.05
DRAWING
FEBRUARY 2026
SS
NO. DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
REVISIONS:
TW P3 AND TW P4
IMPROVEMENTS
DAYTONA BEACH
INTERNATIONAL
AIRPORT
2419905007C001CADD
PROFESSIONAL SEAL
FDOT FM:
FAA AIP: XXXX
XXXX
ENGINEERS & PLANNERS
5555 E. MICHIGAN ST., SUITE 200 - ORLANDO, FL 32822-2779
OFFICE: (407) 599-1122 - FAX: (407) 599-1133 CORPORATE
CERTIFICATE OF AUTHORIZATION NUMBER: 5057
www.avconinc.com
AVCON PROJECT NO.
SHEET OF 60
B
ID
D O
C U
M
EN
TS
GRAPHIC SCALE (FT)
800400200
NORTH
RUNWAY 7L-25R
TAXIWAY N
TAXIWAY P
R U
N W
A Y
-3
TA
XI
W A
Y W
TA
XI
W A
Y E
TW
N
TW
N
TW
N
TW
N
TW
P
TW
P
TW
P
TW
P
TW
N
TW
N
TW N7 TW N8
TW
N
TW
N
TW
N
TW
P
This item has been electronically signed and sealed by using an SHA-1 authentication code. Printed copies of this document are not considered signed and sealed and the SHA-1 authentication code must be verified on any electronic copies.
SURVEY CONTROL
PLAN
RDH
UO
RKH
C001
SEAL on 2/18/2026 This item has been electronically signed and sealed by using an SHA-1 authentication code. Printed copies of this document are not considered signed and sealed and the SHA-1 authentication code must be verified on any electronic copies.
SURVEY CONTROL
PLAN
RDH
UO
RKH
C001
FEBRUARY 2026
SS
NO. DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
REVISIONS:
TW P3 AND TW P4
IMPROVEMENTS
DAYTONA BEACH
INTERNATIONAL
AIRPORT
2419905008C051CADD
PROFESSIONAL SEAL
FDOT FM:
FAA AIP: XXXX
XXXX
ENGINEERS & PLANNERS
5555 E. MICHIGAN ST., SUITE 200 - ORLANDO, FL 32822-2779
OFFICE: (407) 599-1122 - FAX: (407) 599-1133 CORPORATE
CERTIFICATE OF AUTHORIZATION NUMBER: 5057
www.avconinc.com
AVCON PROJECT NO.
SHEET OF 60
B
ID
D O
C U
M
EN
TS
EXISTING TAXIWAY P MILLED DEMOLITION - TYPICAL SECTION
TAXIWAY P OVERLAY PROPOSED CONDITIONS, STABILIZED SHOULDERS
EXIST ℄
PROP ℄
NOTES
ASPHALT PAVEMENT DEMOLITION
DEMOLITION REQUIREMENTS
This item has been electronically signed and sealed by using an SHA-1 authentication code. Printed copies of this document are not considered signed and sealed and the SHA-1 authentication code must be verified on any electronic copies.
TYPICAL SECTIONS
(SHEET 1 OF 2)
RDH
UO
RKH
C051
SEAL on 2/18/2026
TAXIWAY
(REHAB)
TAXIWAYS
(WIDENING)
SECTION SPECIFICATIONS
TAXIWAY
STABILIZED
SHOULDERS
PAVEMENT DESIGN MATRIX
LEGEND
FEBRUARY 2026
SS
NO. DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
REVISIONS:
TW P3 AND TW P4
IMPROVEMENTS
DAYTONA BEACH
INTERNATIONAL
AIRPORT
2419905009C052CADD
PROFESSIONAL SEAL
FDOT FM:
FAA AIP: XXXX
XXXX
ENGINEERS & PLANNERS
5555 E. MICHIGAN ST., SUITE 200 - ORLANDO, FL 32822-2779
OFFICE: (407) 599-1122 - FAX: (407) 599-1133 CORPORATE
CERTIFICATE OF AUTHORIZATION NUMBER: 5057
www.avconinc.com
AVCON PROJECT NO.
SHEET OF 60
B
ID
D O
C U
M
EN
TS
NOTES
TYPICAL TAXIWAY FILLET
WIDENING CONSTRUCTION
PROP ℄
TYPICAL TAXIWAY FILLET WIDENING DEMOLITION
EXIST ℄
FILLET WIDENING INTERFACE
DETAIL - STANDARD
EDGE LIP DETAIL - NEW EOP TO TURF
ASPHALT PAVEMENT DEMOLITION
DEMOLITION REQUIREMENTS
TAXIWAY
(REHAB)
TAXIWAYS
(WIDENING)
SECTION SPECIFICATIONS
TAXIWAY
STABILIZED
SHOULDERS
PAVEMENT DESIGN MATRIX
LEGEND
This item has been electronically signed and sealed by using an SHA-1 authentication code. Printed copies of this document are not considered signed and sealed and the SHA-1 authentication code must be verified on any electronic copies.
TYPICAL SECTIONS
(SHEET 2 OF 2)
RDH
UO
RKH
C052
ST ST
TAXIWAY P
TA
XI
W A
Y P4
TA
XI
W A
Y P3
RUNWAY 7L-25R
2024.199.05
DRAWING
FEBRUARY 2026
SS
NO. DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
REVISIONS:
TW P3 AND TW P4
IMPROVEMENTS
DAYTONA BEACH
INTERNATIONAL
AIRPORT
2419905010C101CADD
PROFESSIONAL SEAL
FDOT FM:
FAA AIP: XXXX
XXXX
ENGINEERS & PLANNERS
5555 E. MICHIGAN ST., SUITE 200 - ORLANDO, FL 32822-2779
OFFICE: (407) 599-1122 - FAX: (407) 599-1133 CORPORATE
CERTIFICATE OF AUTHORIZATION NUMBER: 5057
www.avconinc.com
AVCON PROJECT NO.
SHEET OF 60
B
ID
D O
C U
M
EN
TS
GRAPHIC SCALE (FT)
1206030
NORTH
This item has been electronically signed and sealed by using an SHA-1 authentication code. Printed copies of this document are not considered signed and sealed and the SHA-1 authentication code must be verified on any electronic copies.
EXISTING
CONDITIONS
RDH
UO
RKH
C101
ST ST
TAXIWAY P
ST
ST
ST ST
TA
XI
W A
Y P4
TA
XI
W A
Y P3
RUNWAY 7L-25R
2024.199.05
DRAWING
FEBRUARY 2026
SS
NO. DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
REVISIONS:
TW P3 AND TW P4
IMPROVEMENTS
DAYTONA BEACH
INTERNATIONAL
AIRPORT
2419905011C102CADD
PROFESSIONAL SEAL
FDOT FM:
FAA AIP: XXXX
XXXX
ENGINEERS & PLANNERS
5555 E. MICHIGAN ST., SUITE 200 - ORLANDO, FL 32822-2779
OFFICE: (407) 599-1122 - FAX: (407) 599-1133 CORPORATE
CERTIFICATE OF AUTHORIZATION NUMBER: 5057
www.avconinc.com
AVCON PROJECT NO.
SHEET OF 60
B
ID
D O
C U
M
EN
TS
GRAPHIC SCALE (FT)
1206030
NORTH
DEWATERING REQUIREMENTS
EROSION AND SEDIMENT CONTROL NOTES
LEGEND
This item has been electronically signed and sealed by using an SHA-1 authentication code. Printed copies of this document are not considered signed and sealed and the SHA-1 authentication code must be verified on any electronic copies.
STORMWATER
POLLUTION
PREVENTION PLAN
RDH
UO
RKH
C102
ST ST
TAXIWAY P
RUNWAY 7L-25R
TA
XI
W A
Y P4
TA
XI
W A
Y P3
2024.199.05
DRAWING
FEBRUARY 2026
SS
NO. DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
REVISIONS:
TW P3 AND TW P4
IMPROVEMENTS
DAYTONA BEACH
INTERNATIONAL
AIRPORT
2419905012C201CADD
PROFESSIONAL SEAL
FDOT FM:
FAA AIP: XXXX
XXXX
ENGINEERS & PLANNERS
5555 E. MICHIGAN ST., SUITE 200 - ORLANDO, FL 32822-2779
OFFICE: (407) 599-1122 - FAX: (407) 599-1133 CORPORATE
CERTIFICATE OF AUTHORIZATION NUMBER: 5057
www.avconinc.com
AVCON PROJECT NO.
SHEET OF 60
B
ID
D O
C U
M
EN
TS
GRAPHIC SCALE (FT)
1206030
NORTH
LEGENDNOTES
This item has been electronically signed and sealed by using an SHA-1 authentication code. Printed copies of this document are not considered signed and sealed and the SHA-1 authentication code must be verified on any electronic copies.
DEMOLITION PLAN
RDH
UO
RKH
C201
ST ST
TAXIWAY P
TA
XI
W A
Y P4
TA
XI
W A
Y P3
RUNWAY 7L-25R
1733+00.00 1734+00.00 1735+00.00 1736+00.00 1737+00.00 1738+00.00 1739+00.00 1740+00.00 1741+00.00 1742+00.00 1743+00.00 1744+00.00 1745+00.00 1746+00.00 1747+00.00 1748+00.00 1749+00.00
+0 0.
+0
0.
+0 0.
+0
0.
1904+00.00
1905+00.00 1906+00.00 1907+00.00 1908+00.00 1909+00.00 1910+00.00 1911+00.00 1912+00.00 1913+00.00 1914+00.00 1915+00.00 1916+00.00 1917+00.00
+0 0.
2001+00.00
+0 0.
+0
0.
2004+00.00
2004+50.00
FF
FF FF
FF
FF FF FF
FF FF
FF
2024.199.05
DRAWING
FEBRUARY 2026
SS
NO. DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
REVISIONS:
TW P3 AND TW P4
IMPROVEMENTS
DAYTONA BEACH
INTERNATIONAL
AIRPORT
2419905013C301CADD
PROFESSIONAL SEAL
FDOT FM:
FAA AIP: XXXX
XXXX
ENGINEERS & PLANNERS
5555 E. MICHIGAN ST., SUITE 200 - ORLANDO, FL 32822-2779
OFFICE: (407) 599-1122 - FAX: (407) 599-1133 CORPORATE
CERTIFICATE OF AUTHORIZATION NUMBER: 5057
www.avconinc.com
AVCON PROJECT NO.
SHEET OF 60
B
ID
D O
C U
M
EN
TS
GRAPHIC SCALE (FT)
1206030
NORTH
LEGENDNOTES
DESIGN DATA
FF
This item has been electronically signed and sealed by using an SHA-1 authentication code. Printed copies of this document are not considered signed and sealed and the SHA-1 authentication code must be verified on any electronic copies.
GEOMETRY AND
PAVING PLAN
RDH
UO
RKH
C301
GEOMETRY POINTS
POINT # NORTHING EASTING
GEOMETRY POINTS
POINT # NORTHING EASTING
GEOMETRY POINTS
POINT # NORTHING EASTING
2024.199.05
DRAWING
FEBRUARY 2026
SS
NO. DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
REVISIONS:
TW P3 AND TW P4
IMPROVEMENTS
DAYTONA BEACH
INTERNATIONAL
AIRPORT
2419905014C302CADD
PROFESSIONAL SEAL
FDOT FM:
FAA AIP: XXXX
XXXX
ENGINEERS & PLANNERS
5555 E. MICHIGAN ST., SUITE 200 - ORLANDO, FL 32822-2779
OFFICE: (407) 599-1122 - FAX: (407) 599-1133 CORPORATE
CERTIFICATE OF AUTHORIZATION NUMBER: 5057
www.avconinc.com
AVCON PROJECT NO.
SHEET OF 60
B
ID
D O
C U
M
EN
TS
This item has been electronically signed and sealed by using an SHA-1 authentication code. Printed copies of this document are not considered signed and sealed and the SHA-1 authentication code must be verified on any electronic copies.
GEOMETRY DATA
RDH
UO
RKH
C302
ST ST
ST
ST
+0 0.
+0
0.
+0 0.
+0
0.
+0 0.
+0
0.
+0 0.
+0
0.
1900+00.00 1901+00.00 1902+00.00 1903+00.00 1904+00.00
+0 0.
+0
0.
+0 0.
+0
0.
+0 0.
2004+50.00
2000+00.00 2001+00.00 2002+00.00 2003+00.00 2004+00.00
20.0
22.0
24.0
26.0
28.0
30.0
32.0
34.0
36.0
38.0
40.0
1900+00 1901+00 1902+00 1903+00 1904+00 1905+00 1906+00 1907+00 1908+00 1909+00 1910+00 1911+00
2024.199.05
DRAWING
FEBRUARY 2026
SS
NO. DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
REVISIONS:
TW P3 AND TW P4
IMPROVEMENTS
DAYTONA BEACH
INTERNATIONAL
AIRPORT
2419905015C401CADD
PROFESSIONAL SEAL
FDOT FM:
FAA AIP: XXXX
XXXX
ENGINEERS & PLANNERS
5555 E. MICHIGAN ST., SUITE 200 - ORLANDO, FL 32822-2779
OFFICE: (407) 599-1122 - FAX: (407) 599-1133 CORPORATE
CERTIFICATE OF AUTHORIZATION NUMBER: 5057
www.avconinc.com
AVCON PROJECT NO.
SHEET OF 60
B
ID
D O
C U
M
EN
TS
GRAPHIC SCALE (FT)
1206030
NORTH
LEGEND: NOTES
20.0
22.0
24.0
26.0
28.0
30.0
32.0
34.0
36.0
38.0
40.0
This item has been electronically signed and sealed by using an SHA-1 authentication code. Printed copies of this document are not considered signed and sealed and the SHA-1 authentication code must be verified on any electronic copies.
GRADING AND
DRAINAGE PLAN
(SHEET 1 OF 3)
RDH
UO
RKH
C401
ST
ST ST ST
1733+00.00 1734+00.00 1735+00.00 1736+00.00 1737+00.00 1738+00.00 1739+00.00 1740+00.00 1741+00.00 1742+00.00 1743+00.00 1744+00.00 1745+00.00 1746+00.00 1747+00.00 1748+00.00 1749+00.00
+0 0.
+0
0.
+0 0.
+0
0.
1904+00.00
1905+00.00 1906+00.00 1907+00.00 1908+00.00 1909+00.00 1910+00.00 1911+00.00 1912+00.00 1913+00.00 1914+00.00 1915+00.00 1916+00.00 1917+00.00 1918+00.00
2004+50.00
+0 0.
+0
0.
+0 0.
+0
0.
+0 0.
1902+00 1903+00 1904+00 1905+00 1906+00 1907+00 1908+00 1909+00 1910+00 1911+00 1912+00 1913+00 1914+00 1915+00 1916+00 1917+00 1918+00
2024.199.05
DRAWING
FEBRUARY 2026
SS
NO. DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
REVISIONS:
TW P3 AND TW P4
IMPROVEMENTS
DAYTONA BEACH
INTERNATIONAL
AIRPORT
2419905016C402CADD
PROFESSIONAL SEAL
FDOT FM:
FAA AIP: XXXX
XXXX
ENGINEERS & PLANNERS
5555 E. MICHIGAN ST., SUITE 200 - ORLANDO, FL 32822-2779
OFFICE: (407) 599-1122 - FAX: (407) 599-1133 CORPORATE
CERTIFICATE OF AUTHORIZATION NUMBER: 5057
www.avconinc.com
AVCON PROJECT NO.
SHEET OF 60
B
ID
D O
C U
M
EN
TS
GRAPHIC SCALE (FT)
1206030
NORTH
LEGEND: NOTES
20.0
22.0
24.0
26.0
28.0
30.0
32.0
34.0
36.0
38.0
40.0
20.0
22.0
24.0
26.0
28.0
30.0
32.0
34.0
36.0
38.0
40.0
This item has been electronically signed and sealed by using an SHA-1 authentication code. Printed copies of this document are not considered signed and sealed and the SHA-1 authentication code must be verified on any electronic copies.
GRADING AND
DRAINAGE PLAN
(SHEET 2 OF 3)
RDH
UO
RKH
C402
ST ST
ST
ST
+0 0.
+0
0.
+0 0.
+0
0.
+0 0.
+0
0.
+0 0.
+0
0.
1900+00.00 1901+00.00 1902+00.00 1903+00.00 1904+00.00
+0 0.
+0
0.
+0 0.
+0
0.
+0 0.
2004+50.00
2000+00.00 2001+00.00 2002+00.00 2003+00.00 2004+00.00
PROFILE OF Alignment - 20
20.0
22.0
24.0
26.0
28.0
30.0
32.0
34.0
36.0
38.0
40.0
20.0
22.0
24.0
26.0
28.0
30.0
32.0
34.0
36.0
38.0
40.0
2000+00 2001+00 2002+00 2003+00 2004+00 2005+00
2024.199.05
DRAWING
FEBRUARY 2026
SS
NO. DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
REVISIONS:
TW P3 AND TW P4
IMPROVEMENTS
DAYTONA BEACH
INTERNATIONAL
AIRPORT
2419905017C403CADD
PROFESSIONAL SEAL
FDOT FM:
FAA AIP: XXXX
XXXX
ENGINEERS & PLANNERS
5555 E. MICHIGAN ST., SUITE 200 - ORLANDO, FL 32822-2779
OFFICE: (407) 599-1122 - FAX: (407) 599-1133 CORPORATE
CERTIFICATE OF AUTHORIZATION NUMBER: 5057
www.avconinc.com
AVCON PROJECT NO.
SHEET OF 60
B
ID
D O
C U
M
EN
TS
GRAPHIC SCALE (FT)
1206030
NORTH
LEGEND: NOTES
This item has been electronically signed and sealed by using an SHA-1 authentication code. Printed copies of this document are not considered signed and sealed and the SHA-1 authentication code must be verified on any electronic copies.
GRADING AND
DRAINAGE PLAN
(SHEET 3 OF 3)
RDH
UO
RKH
C403
FEBRUARY 2026
SS
NO. DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
REVISIONS:
TW P3 AND TW P4
IMPROVEMENTS
DAYTONA BEACH
INTERNATIONAL
AIRPORT
2419905018C501CADD
PROFESSIONAL SEAL
FDOT FM:
FAA AIP: XXXX
XXXX
ENGINEERS & PLANNERS
5555 E. MICHIGAN ST., SUITE 200 - ORLANDO, FL 32822-2779
OFFICE: (407) 599-1122 - FAX: (407) 599-1133 CORPORATE
CERTIFICATE OF AUTHORIZATION NUMBER: 5057
www.avconinc.com
AVCON PROJECT NO.
SHEET OF 60
B
ID
D O
C U
M
EN
TS
FF TYPE FF FLEXIBLE PAVEMENT BUTT JOINT
NOTE
COMPACTION SCHEDULE - EMBANKMENTS
FILL SECTION CUT SECTION
ASPHALT PAVING LANE DETAIL - LONGITUDINAL SECTION
ASPHALT TRANSITION DETAIL BETWEEN PHASES
NOTE
NOTE
This item has been electronically signed and sealed by using an SHA-1 authentication code. Printed copies of this document are not considered signed and sealed and the SHA-1 authentication code must be verified on any electronic copies.
CONSTRUCTION
DETAILS
RDH
UO
RKH
C501
ST ST
2024.199.05
DRAWING
FEBRUARY 2026
SS
NO. DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
REVISIONS:
TW P3 AND TW P4
IMPROVEMENTS
DAYTONA BEACH
INTERNATIONAL
AIRPORT
2419905019C601CADD
PROFESSIONAL SEAL
FDOT FM:
FAA AIP: XXXX
XXXX
ENGINEERS & PLANNERS
5555 E. MICHIGAN ST., SUITE 200 - ORLANDO, FL 32822-2779
OFFICE: (407) 599-1122 - FAX: (407) 599-1133 CORPORATE
CERTIFICATE OF AUTHORIZATION NUMBER: 5057
www.avconinc.com
AVCON PROJECT NO.
SHEET OF 60
B
ID
D O
C U
M
EN
TS
GRAPHIC SCALE (FT)
1206030
NORTH
This item has been electronically signed and sealed by using an SHA-1 authentication code. Printed copies of this document are not considered signed and sealed and the SHA-1 authentication code must be verified on any electronic copies.
MARKING PLAN
RDH
UO
RKH
C601
GENERAL MARKING NOTES
SURFACE PAINTED HOLD POSITION MARKING DETAIL
PATTERN A RUNWAY HOLDING POSTION MARKING DETAIL
NOTES
TAXIWAY CENTERLINE INTERSECTION
WITH RUNWAY EDGE MARKING DETAIL
RUNWAY EDGE MARKING DETAIL
2024.199.05
DRAWING
FEBRUARY 2026
SS
NO. DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
REVISIONS:
TW P3 AND TW P4
IMPROVEMENTS
DAYTONA BEACH
INTERNATIONAL
AIRPORT
2419905020C611-C612CADD
PROFESSIONAL SEAL
FDOT FM:
FAA AIP: XXXX
XXXX
ENGINEERS & PLANNERS
5555 E. MICHIGAN ST., SUITE 200 - ORLANDO, FL 32822-2779
OFFICE: (407) 599-1122 - FAX: (407) 599-1133 CORPORATE
CERTIFICATE OF AUTHORIZATION NUMBER: 5057
www.avconinc.com
AVCON PROJECT NO.
SHEET OF 60
B
ID
D O
C U
M
EN
TS
This item has been electronically signed and sealed by using an SHA-1 authentication code. Printed copies of this document are not considered signed and sealed and the SHA-1 authentication code must be verified on any electronic copies.
MARKING DETAILS
(SHEET 1 OF 2)
RDH
UO
RKH
C611
ENHANCED TAXIWAY CENTERLINE MARKING DETAIL
TAXIWAY CENTERLINE MARKING DETAIL
TAXIWAY CENTERLINE MARKING LEAD-IN TO RUNWAY DETAIL
NOTES
DASHED TAXIWAY EDGE STRIPING DETAIL
2024.199.05
DRAWING
FEBRUARY 2026
SS
NO. DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
REVISIONS:
TW P3 AND TW P4
IMPROVEMENTS
DAYTONA BEACH
INTERNATIONAL
AIRPORT
2419905020C611-C612CADD
PROFESSIONAL SEAL
FDOT FM:
FAA AIP: XXXX
XXXX
ENGINEERS & PLANNERS
5555 E. MICHIGAN ST., SUITE 200 - ORLANDO, FL 32822-2779
OFFICE: (407) 599-1122 - FAX: (407) 599-1133 CORPORATE
CERTIFICATE OF AUTHORIZATION NUMBER: 5057
www.avconinc.com
AVCON PROJECT NO.
SHEET OF 60
B
ID
D O
C U
M
EN
TS
This item has been electronically signed and sealed by using an SHA-1 authentication code. Printed copies of this document are not considered signed and sealed and the SHA-1 authentication code must be verified on any electronic copies.
MARKING DETAILS
(SHEET 2 OF 2)
RDH
UO
RKH
C612
NOTES:
SPECIAL NOTE TO CONTRACTOR:
This item has been electronically signed and sealed by using an SHA-1 authentication code. Printed copies of this document are not considered signed and sealed and the SHA-1 authentication code must be verified on any electronic copies.
AIRFIELD
ELECTRICAL
GENERAL NOTES
MAG
CB
MAG
E001
SEAL on 2/18/2026
2024.199.05
DRAWING
FEBRUARY 2026
SS
NO. DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
REVISIONS:
TW P3 AND TW P4
IMPROVEMENTS
DAYTONA BEACH
INTERNATIONAL
AIRPORT
2419905021E001CADD
PROFESSIONAL SEAL
FDOT FM:
FAA AIP: XXXX
XXXX
ENGINEERS & PLANNERS
5555 E. MICHIGAN ST., SUITE 200 - ORLANDO, FL 32822-2779
OFFICE: (407) 599-1122 - FAX: (407) 599-1133 CORPORATE
CERTIFICATE OF AUTHORIZATION NUMBER: 5057
www.avconinc.com
AVCON PROJECT NO.
SHEET OF 60
B
ID
D O
C U
M
EN
TS
NOTE:
MODIFIER DESCRIPTION
A
RE
SYMBOL EXISTING ITEM DESCRIPTION ABBREVIATIONS
T
SYMBOL NEW ITEM DESCRIPTION SYMBOL NEW ITEM DESCRIPTION
NE
2024.199.05
DRAWING
FEBRUARY 2026
SS
NO. DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
REVISIONS:
TW P3 AND TW P4
IMPROVEMENTS
DAYTONA BEACH
INTERNATIONAL
AIRPORT
2419905022E002CADD
PROFESSIONAL SEAL
FDOT FM:
FAA AIP: XXXX
XXXX
ENGINEERS & PLANNERS
5555 E. MICHIGAN ST., SUITE 200 - ORLANDO, FL 32822-2779
OFFICE: (407) 599-1122 - FAX: (407) 599-1133 CORPORATE
CERTIFICATE OF AUTHORIZATION NUMBER: 5057
www.avconinc.com
AVCON PROJECT NO.
SHEET OF 60
B
ID
D O
C U
M
EN
TS
This item has been electronically signed and sealed by using an SHA-1 authentication code. Printed copies of this document are not considered signed and sealed and the SHA-1 authentication code must be verified on any electronic copies.
AIRFLIED
ELECTRICAL
LEGEND AND
ABBREVIATIONS
MAG
CB
MAG
E002
SEAL on 4/1/2025
AC
WV
E102 E202 E302
E101 E201 E301
2024.199.05
DRAWING
FEBRUARY 2026
SS
NO. DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
REVISIONS:
TW P3 AND TW P4
IMPROVEMENTS
DAYTONA BEACH
INTERNATIONAL
AIRPORT
2419905023E100CADD
PROFESSIONAL SEAL
FDOT FM:
FAA AIP: XXXX
XXXX
ENGINEERS & PLANNERS
5555 E. MICHIGAN ST., SUITE 200 - ORLANDO, FL 32822-2779
OFFICE: (407) 599-1122 - FAX: (407) 599-1133 CORPORATE
CERTIFICATE OF AUTHORIZATION NUMBER: 5057
www.avconinc.com
AVCON PROJECT NO.
SHEET OF 60
B
ID
D O
C U
M
EN
TS
GRAPHIC SCALE IN FEET
0 1000250 500
NORTH
KEY SHEET NOTES
This item has been electronically signed and sealed by using an SHA-1 authentication code. Printed copies of this document are not considered signed and sealed and the SHA-1 authentication code must be verified on any electronic copies.
AIRFIELD LIGHTING
SHEET KEY PLAN
MAG
CB
MAG
E100
SEAL on 2/18/2026
TW
E
RUNWAY 7L-25R RUNWAY 7L-25R
TW
N
TW
N
TW N
TW
N
TW
N
TW
N
TW
N
TW N7
TW N8
TW N TW N TW N
TW
W
R W
6-
TW
P
TW
P
TW
P
TW
P
TW P TW P TW P TW P TW P
TW W1 TW E1
TW W TW E
TW
E
TW
E
TW
E
TW
N
TW
N
TW
N
TW E2TW W2
TW
W
TW
W
TW STW S
TW E3TW W3
TW E4
TW W4
TW W TW E
TW
C
TW
C
2 TW A
TW
C
TW
W
TW
E
TW
P
TW
T
TW
M
TW
M
TW S
TW T
RUNWAY 7R-25L
TW
S
TW
RUNWAY 7L 25 R
TW
"P
3"
TW
"P
2"
TW "P"
ST
ST
ST
ST
ST
ST
RUNWAY 7L 25 RRUNWAY 7L 25 R
TW
"B
1"
A1 A1A1A1
P B
1B1 PP3
P
B1
P3P
P3P2
7L-25RP37L-25RP2
P P3
M A
TC
H
LI
N
E
SH
EE
T
E1
S
TA
TI
O
N
GRAPHIC SCALE IN FEET
0 10025 50
NORTH
NOTES:
This item has been electronically signed and sealed by using an SHA-1 authentication code. Printed copies of this document are not considered signed and sealed and the SHA-1 authentication code must be verified on any electronic copies.
EXISTING
CONDITIONS AND
DEMOLITION PLAN
(SHEET 1 OF 2)
MAG
CB
MAG
E101
SEAL on 8/18/2025
2024.199.05
DRAWING
FEBRUARY 2026
SS
NO. DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
REVISIONS:
TW P3 AND TW P4
IMPROVEMENTS
DAYTONA BEACH
INTERNATIONAL
AIRPORT
2419905024E101-E102CADD
PROFESSIONAL SEAL
FDOT FM:
FAA AIP: XXXX
XXXX
ENGINEERS & PLANNERS
5555 E. MICHIGAN ST., SUITE 200 - ORLANDO, FL 32822-2779
OFFICE: (407) 599-1122 - FAX: (407) 599-1133 CORPORATE
CERTIFICATE OF AUTHORIZATION NUMBER: 5057
www.avconinc.com
AVCON PROJECT NO.
SHEET OF 60
B
ID
D O
C U
M
RUNWAY
7L 25 R
TW "P" TW "P"
TW
"P
5"
TW
"B3"
ST ST ST ST ST ST ST
ST
ST
TW
"B
2"
RUNWAY 7L 25 R RUNWAY 7L 25 R
A1A1
P B
B2 P
B2 P
N NN N
P5 P
7L-25RP5
P5 P5
P5P
P5 P
B3 P
B3 P
JP JP
TT
JPJP
TT
T
T
T
T T
TT T
T
T T
T
T T
T
T T
T T
T
T
N
T
T T
T T
N
TT
TT
T
TT T
T
T
T
T
T
TTTTT T
T
T T
T T
T T
T T
T
T
GRAPHIC SCALE IN FEET
0 10025 50
NORTH
M A
TC
H
LI
N
E
SH
EE
T
E1
S
TA
TI
O
N
NOTES:
This item has been electronically signed and sealed by using an SHA-1 authentication code. Printed copies of this document are not considered signed and sealed and the SHA-1 authentication code must be verified on any electronic copies.
EXISTING
CONDITIONS AND
DEMOLITION PLAN
(SHEET 2 OF 2)
MAG
CB
MAG
E102
SEAL on 8/29/2025
2024.199.05
DRAWING
FEBRUARY 2026
SS
NO. DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
REVISIONS:
TW P3 AND TW P4
IMPROVEMENTS
DAYTONA BEACH
INTERNATIONAL
AIRPORT
2419905024E101-E102CADD
PROFESSIONAL SEAL
FDOT FM:
FAA AIP: XXXX
XXXX
ENGINEERS & PLANNERS
5555 E. MICHIGAN ST., SUITE 200 - ORLANDO, FL 32822-2779
OFFICE: (407) 599-1122 - FAX: (407) 599-1133 CORPORATE
CERTIFICATE OF AUTHORIZATION NUMBER: 5057
www.avconinc.com
AVCON PROJECT NO.
SHEET OF 60
B
ID
D O
C U
M
ST
ST
ST
ST
A
A
T T
T T
T
T T
T
T
T T
T
T
T T
T
T T
T T
TTTT
T
T
T
7L-25RP3
P4P3 P3
P4
P4
PP3 P
B1 P
P4 P
P3
TT
T
T
T
T
T T
T T
T T
RE
T
T
A
3M
2M
TW
"P
3"
TW
"P
4"
TW "P" TW "P"
TW
"B
1"
3M
3M
B1 P
3M
P B
A
T T
T T
T T
T
T
T T T
T T
NE
N
E
A
T T
T
T
T T
T T
A
T T
T T
T T
T
T
N E
N E
NE
NE
NE
N E
NENENE
NE
T
2M 2M
2M
4M
2M
4M
2M
7L-25RP4
TW "P"
A
A
T T
T T
T
T T
T
T
T T
T
T
T T
T
T T
T T
TTTT
T
T
T
7L-25RP3
P4P3 P3
P4
P4
PP3 P
B1 P
P4 P
P3
TT
T
T
T
T
T T
T T
T T
RE
T
T
A
3M
2M
TW
"P
3"
TW
"P
4"
TW "P" TW "P"
TW
"B
1"
3M
3M
B1 P
3M
P B
A
T T
T T
T T
T
T
T T T
T T
NE
N
E
A
T T
T
T
T T
T T
A
T T
T T
T T
T
T
N E
N E
NE
NE
NE
N E
NENENE
NE
T
2M 2M
2M
4M
2M
4M
2M
7L-25RP4
TW "P"
2024.199.05
DRAWING
FEBRUARY 2026
SS
NO. DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
REVISIONS:
TW P3 AND TW P4
IMPROVEMENTS
DAYTONA BEACH
INTERNATIONAL
AIRPORT
2419905025E201-E202CADD
PROFESSIONAL SEAL
FDOT FM:
FAA AIP: XXXX
XXXX
ENGINEERS & PLANNERS
5555 E. MICHIGAN ST., SUITE 200 - ORLANDO, FL 32822-2779
OFFICE: (407) 599-1122 - FAX: (407) 599-1133 CORPORATE
CERTIFICATE OF AUTHORIZATION NUMBER: 5057
www.avconinc.com
AVCON PROJECT NO.
SHEET OF 60
B
ID
D O
C U
M
EN
TS
M A
TC
H
LI
N
E
SH
EE
T
E2
S
TA
TI
O
N
GRAPHIC SCALE IN FEET
0 10025 50
NORTH
NOTES APPLICABLE TO SHEET E201-E202:
This item has been electronically signed and sealed by using an SHA-1 authentication code. Printed copies of this document are not considered signed and sealed and the SHA-1 authentication code must be verified on any electronic copies.
AIRFIELD LIGHTING
LAYOUT PLAN
(SHEET 1 OF 2)
MAG
CB
MAG
E201
ST ST ST ST ST ST ST
ST
T
TT
T
T
TTT
B2 P
3M
TW
"P
5"
TW "P"
TW
"B
2"
TW
"B3"
3M
B2 P
3M
P B
N E
NE
NE
N E
NE
NE
TW "P"
T
TT
T
T
TTT
B2 P
3M
TW
"P
5"
TW "P"
TW
"B
2"
TW
"B3"
3M
B2 P
3M
P B
N E
NE
NE
N E
NE
NE
TW "P"
P5 P
7L-25RP5
P5 P5
P5P
P5 P
B3 P
B3 P
2024.199.05
DRAWING
FEBRUARY 2026
SS
NO. DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
REVISIONS:
TW P3 AND TW P4
IMPROVEMENTS
DAYTONA BEACH
INTERNATIONAL
AIRPORT
2419905025E201-E202CADD
PROFESSIONAL SEAL
FDOT FM:
FAA AIP: XXXX
XXXX
ENGINEERS & PLANNERS
5555 E. MICHIGAN ST., SUITE 200 - ORLANDO, FL 32822-2779
OFFICE: (407) 599-1122 - FAX: (407) 599-1133 CORPORATE
CERTIFICATE OF AUTHORIZATION NUMBER: 5057
www.avconinc.com
AVCON PROJECT NO.
SHEET OF 60
B
ID
D O
C U
M
EN
TS
GRAPHIC SCALE IN FEET
0 10025 50
NORTH
M A
TC
H
LI
N
E
SH
EE
T
E2
S
TA
TI
O
N
NOTES:
This item has been electronically signed and sealed by using an SHA-1 authentication code. Printed copies of this document are not considered signed and sealed and the SHA-1 authentication code must be verified on any electronic copies.
AIRFIELD LIGHTING
LAYOUT PLAN
(SHEET 2 OF 2)
MAG
CB
MAG
E202
A1 A1A1A1
A
A
T T
T T
T
T T
T
T
T T
T
T
T T
T
T T
T T
TTTT
T
T
T
7L-25RP3
P4P3 P3
P4
P4
PP3 P
B1 P
P4 P
P3
JP JP JP JP
TT
T
T
JP
T
T
T T
T T
T T
RE
T
T
A
3M
2M
TW
"P
3"
TW
"P
4"
TW "P" TW "P"
TW
"B
1"
3M
3M
B1 P
3M
P B
A
T T
T T
T T
T
T
T T T
T T
NE
N
E
A
T T
T
T
T T
T T
A
T T
T T
T T
T
T
N E
N E
NE
NE
NE
N E
NENENE
NE
T
2M 2M
2M
4M
2M
4M
2M
7L-25RP4
TW "P"
2024.199.05
DRAWING
FEBRUARY 2026
SS
NO. DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
REVISIONS:
TW P3 AND TW P4
IMPROVEMENTS
DAYTONA BEACH
INTERNATIONAL
AIRPORT
2419905026E301-E302CADD
PROFESSIONAL SEAL
FDOT FM:
FAA AIP: XXXX
XXXX
ENGINEERS & PLANNERS
5555 E. MICHIGAN ST., SUITE 200 - ORLANDO, FL 32822-2779
OFFICE: (407) 599-1122 - FAX: (407) 599-1133 CORPORATE
CERTIFICATE OF AUTHORIZATION NUMBER: 5057
www.avconinc.com
AVCON PROJECT NO.
SHEET OF 60
B
ID
D O
C U
M
EN
TS
M A
TC
H
LI
N
E
SH
EE
T
E3
S
TA
TI
O
N
GRAPHIC SCALE IN FEET
0 10025 50
NORTH
NOTES:
This item has been electronically signed and sealed by using an SHA-1 authentication code. Printed copies of this document are not considered signed and sealed and the SHA-1 authentication code must be verified on any electronic copies.
AIRFIELD LIGHTING
CIRCUITING PLAN
(SHEET 1 OF 2)
MAG
CB
MAG
E301
SEAL on 8/18/2025
A1A1
N NN N
P5 P
7L-25RP5
P5 P5
P5P
P5 P
B3 P
B3 P
JP JP
TT
JPJP
TT
T
T
T
T T
TT T
T
T T
T
T T
T
T T
T T
T
T
N
T
T T
T T
N
TT
TT
T
TT T
T
T
T
T
T
TTTTT T
T
T T
T T
T T
T T
T
T T
TT
T
T
TTT
B2
P JP
3M
TW
"P
5"
TW "P"
TW
"B
2"
TW
"B3"
3M
B2 P
3M
P B
N E
NE
NE
N E
NE
NE
TW "P"
2024.199.05
DRAWING
FEBRUARY 2026
SS
NO. DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
REVISIONS:
TW P3 AND TW P4
IMPROVEMENTS
DAYTONA BEACH
INTERNATIONAL
AIRPORT
2419905026E301-E302CADD
PROFESSIONAL SEAL
FDOT FM:
FAA AIP: XXXX
XXXX
ENGINEERS & PLANNERS
5555 E. MICHIGAN ST., SUITE 200 - ORLANDO, FL 32822-2779
OFFICE: (407) 599-1122 - FAX: (407) 599-1133 CORPORATE
CERTIFICATE OF AUTHORIZATION NUMBER: 5057
www.avconinc.com
AVCON PROJECT NO.
SHEET OF 60
B
ID
D O
C U
M
EN
TS
GRAPHIC SCALE IN FEET
0 10025 50
NORTH
M A
TC
H
LI
N
E
SH
EE
T
E3
S
TA
TI
O
N
NOTES:
This item has been electronically signed and sealed by using an SHA-1 authentication code. Printed copies of this document are not considered signed and sealed and the SHA-1 authentication code must be verified on any electronic copies.
AIRFIELD LIGHTING
CIRCUITING PLAN
(SHEET 2 OF 2)
MAG
CB
MAG
E302
AC
WV
TAXIWAY NOVEMBER
TAXIWAY PAPA
TAXIWAY NOVEMBER
RUNWAY 7L-25R
B3 B4
C2C1
N7N6
B1 B2
P3 P4 P5 P6
T
AC
AC
WV
TAXIWAY NOVEMBER
TAXIWAY PAPA
TAXIWAY NOVEMBER
RUNWAY 7L-25R
B3 B4
N7N6
B1 B2
P3 P4 P5 P6
2024.199.05
DRAWING
FEBRUARY 2026
SS
NO. DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
REVISIONS:
TW P3 AND TW P4
IMPROVEMENTS
DAYTONA BEACH
INTERNATIONAL
AIRPORT
2419905027E303CADD
PROFESSIONAL SEAL
FDOT FM:
FAA AIP: XXXX
XXXX
ENGINEERS & PLANNERS
5555 E. MICHIGAN ST., SUITE 200 - ORLANDO, FL 32822-2779
OFFICE: (407) 599-1122 - FAX: (407) 599-1133 CORPORATE
CERTIFICATE OF AUTHORIZATION NUMBER: 5057
www.avconinc.com
AVCON PROJECT NO.
SHEET OF 60
B
ID
D O
C U
M
EN
TS
GRAPHIC SCALE IN FEET
0 400100 200
NORTH
DAYTONA INTERNATIOAL AIRPORT, AIRFIELD LIGHTING COLOR CIRCUIT DIAGRAM & CIRCUIT DESIGNATIONS
RUNWAY GUARD LIGHT AND RUNWAY SIGN CIRCUIT DIAGRAM FOR SCHEDULE A & B WORK
TAXIWAY PAPA EDGE LIGHT CIRCUIT DIAGRAM FOR SCHEDULE A & B WORK
This item has been electronically signed and sealed by using an SHA-1 authentication code. Printed copies of this document are not considered signed and sealed and the SHA-1 authentication code must be verified on any electronic copies.
AIRFIELD LIGHTING
OVERALL
CIRCUITING
DIAGRAM
MAG
CB
MAG
E303
T T
T T
T
T T
T T
T T
T
T
T T
T
TT
T
T TT T
T TTTT
T
T
T
TTT
T
TT
T
T
T
T
T T
T T
T T
RE
T
T
A
A
T T
T T
T T
T
T
T T T
T
T
NE
N
E
A
T T
T
T
T T
T T
A
T T
T T
T T
T
T
N E
N E
NE
NE
NE
N E
NE
N E
NENENE
NE
NE
N E
NE
NET
TW
"B
2"
7L-25R
TW
"P
3"
TW
"P
4"
TW "P"
RUNWAY 7L-25R
7L-25R
TW "P"TW "P"
RUNWAY 7L-25R
TW
"B
1"
2024.199.05
DRAWING
FEBRUARY 2026
SS
NO. DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
REVISIONS:
TW P3 AND TW P4
IMPROVEMENTS
DAYTONA BEACH
INTERNATIONAL
AIRPORT
2419905028E401CADD
PROFESSIONAL SEAL
FDOT FM:
FAA AIP: XXXX
XXXX
ENGINEERS & PLANNERS
5555 E. MICHIGAN ST., SUITE 200 - ORLANDO, FL 32822-2779
OFFICE: (407) 599-1122 - FAX: (407) 599-1133 CORPORATE
CERTIFICATE OF AUTHORIZATION NUMBER: 5057
www.avconinc.com
AVCON PROJECT NO.
SHEET OF 60
B
ID
D O
C U
M
EN
TS
GRAPHIC SCALE IN FEET
0 20050 100
NORTH
LIGHTING CIRCUIT
FIXTURE NUMBERING FORMAT
FIXTURE ID & NUMBERS
NOTES:
This item has been electronically signed and sealed by using an SHA-1 authentication code. Printed copies of this document are not considered signed and sealed and the SHA-1 authentication code must be verified on any electronic copies.
AIRFIELD LIGHTING
NUMBERING PLAN
SHEET
MAG
CB
MAG
E401
TYPICAL L-868B
DEEP BASE CAN
TYPICAL SEMI-FLUSH FIXTURE INSTALLATION WITH
DEEP BASE CAN AND TOP CAN SECTION TO BE
INSTALLED IN ASPHALT PAVEMENT
MAXIMUM SEMIFLUSH - FLUSH FIXTURE HEIGHT
REBAR DETAIL FOR ALL L-868 BASE CANS
SEMI-FLUSH FIXTURE NOTES:
PLAN A-A
DETAIL ''A''
FIXTURE INSTALLATION TOLERANCES
This item has been electronically signed and sealed by using an SHA-1 authentication code. Printed copies of this document are not considered signed and sealed and the SHA-1 authentication code must be verified on any electronic copies.
SEMIFLUSH FIXTURE
DETAILS (SHEET 1
OF 2)
MAG
CB
MAG
E501
SEAL on 2/18/2026
2024.199.05
DRAWING
FEBRUARY 2026
SS
NO. DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
REVISIONS:
TW P3 AND TW P4
IMPROVEMENTS
DAYTONA BEACH
INTERNATIONAL
AIRPORT
2419905029E501CADD
PROFESSIONAL SEAL
FDOT FM:
FAA AIP: XXXX
XXXX
ENGINEERS & PLANNERS
5555 E. MICHIGAN ST., SUITE 200 - ORLANDO, FL 32822-2779
OFFICE: (407) 599-1122 - FAX: (407) 599-1133 CORPORATE
CERTIFICATE OF AUTHORIZATION NUMBER: 5057
www.avconinc.com
AVCON PROJECT NO.
SHEET OF 60
B
ID
D O
C U
M
BASE CAN DETAIL
NEWSEMIFLUSH FIXTURE IN NEW PAVEMENT
SUGGESTED BASE CAN AND TRENCHED
CONDUIT INSTALLATION SEQUENCE
SECTION A - CONDUIT
CROSS SECTION.
BASE CAN DETAIL
NEW INPAVEMENT FIXTURE IN NEW PAVEMENT.
INSTALLATION SHOWN PRIOR TO PAVING OPERATIONS.
A
DETAIL "A" FOR BASE CAN
INSTALLATION IN BITUMINOUS
PAVEMENT
GENERAL NOTE:
SEE SEMIFLUSH FIXTURE DETAILS
AND ** NOTES ON SHEET E501.
NOTE:
2024.199.05
DRAWING
FEBRUARY 2026
SS
NO. DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
REVISIONS:
TW P3 AND TW P4
IMPROVEMENTS
DAYTONA BEACH
INTERNATIONAL
AIRPORT
2419905030E502CADD
PROFESSIONAL SEAL
FDOT FM:
FAA AIP: XXXX
XXXX
ENGINEERS & PLANNERS
5555 E. MICHIGAN ST., SUITE 200 - ORLANDO, FL 32822-2779
OFFICE: (407) 599-1122 - FAX: (407) 599-1133 CORPORATE
CERTIFICATE OF AUTHORIZATION NUMBER: 5057
www.avconinc.com
AVCON PROJECT NO.
SHEET OF 60
B
ID
D O
C U
M
EN
TS
This item has been electronically signed and sealed by using an SHA-1 authentication code. Printed copies of this document are not considered signed and sealed and the SHA-1 authentication code must be verified on any electronic copies.
SEMIFLUSH FIXTURE
DETAILS (SHEET 2
OF 2)
MAG
CB
MAG
E502
TYPICAL INSTALLATION DETAIL FOR L-867B
TELESCOPING BASE CAN IN NEW ASPHALT PAVEMENT SECTION A-A
ELEVATED FIXTURE NOTES:
TYPICAL L-867B
TELESCOPING BASE CAN
A
2024.199.05
DRAWING
FEBRUARY 2026
SS
NO. DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
REVISIONS:
TW P3 AND TW P4
IMPROVEMENTS
DAYTONA BEACH
INTERNATIONAL
AIRPORT
2419905031E503CADD
PROFESSIONAL SEAL
FDOT FM:
FAA AIP: XXXX
XXXX
ENGINEERS & PLANNERS
5555 E. MICHIGAN ST., SUITE 200 - ORLANDO, FL 32822-2779
OFFICE: (407) 599-1122 - FAX: (407) 599-1133 CORPORATE
CERTIFICATE OF AUTHORIZATION NUMBER: 5057
www.avconinc.com
AVCON PROJECT NO.
SHEET OF 60
B
ID
D O
C U
M
EN
TS
This item has been electronically signed and sealed by using an SHA-1 authentication code. Printed copies of this document are not considered signed and sealed and the SHA-1 authentication code must be verified on any electronic copies.
ELEVATED FIXTURE
DETAILS (SHEET 1
OF 3)
MAG
CB
MAG
E503
TYPICAL L-867B BASE CAN
SEE ELEVATED FIXTURE DETAILS AND NOTES
SHEET E503 FOR APPLICABLE NOTES.
NOTE:
PRECAST L-867B BASE CAN - PLAN VIEW
PRECAST L-867 BASE CAN - ELEVATION
2024.199.05
DRAWING
FEBRUARY 2026
SS
NO. DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
REVISIONS:
TW P3 AND TW P4
IMPROVEMENTS
DAYTONA BEACH
INTERNATIONAL
AIRPORT
2419905032E504CADD
PROFESSIONAL SEAL
FDOT FM:
FAA AIP: XXXX
XXXX
ENGINEERS & PLANNERS
5555 E. MICHIGAN ST., SUITE 200 - ORLANDO, FL 32822-2779
OFFICE: (407) 599-1122 - FAX: (407) 599-1133 CORPORATE
CERTIFICATE OF AUTHORIZATION NUMBER: 5057
www.avconinc.com
AVCON PROJECT NO.
SHEET OF 60
B
ID
D O
C U
M
EN
TS
This item has been electronically signed and sealed by using an SHA-1 authentication code. Printed copies of this document are not considered signed and sealed and the SHA-1 authentication code must be verified on any electronic copies.
ELEVATED FIXTURE
DETAILS (SHEET 2
OF 3)
MAG
CB
MAG
E504
TO RUNWAY
RUNWAY GUARD LIGHT FIXTURE LAYOUT
SEE ELEVATED FIXTURE DETAILS AND NOTES
SHEET E503 FOR APPLICABLE NOTES.
NOTE:
PRECAST L-867B BASE CAN - PLAN VIEW
INSTALLATION DETAIL FOR L-804 RGL ON
L-867B BASE CAN IN TURF
2024.199.05
DRAWING
FEBRUARY 2026
SS
NO. DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
REVISIONS:
TW P3 AND TW P4
IMPROVEMENTS
DAYTONA BEACH
INTERNATIONAL
AIRPORT
2419905033E505CADD
PROFESSIONAL SEAL
FDOT FM:
FAA AIP: XXXX
XXXX
ENGINEERS & PLANNERS
5555 E. MICHIGAN ST., SUITE 200 - ORLANDO, FL 32822-2779
OFFICE: (407) 599-1122 - FAX: (407) 599-1133 CORPORATE
CERTIFICATE OF AUTHORIZATION NUMBER: 5057
www.avconinc.com
AVCON PROJECT NO.
SHEET OF 60
B
ID
D O
C U
M
EN
TS
This item has been electronically signed and sealed by using an SHA-1 authentication code. Printed copies of this document are not considered signed and sealed and the SHA-1 authentication code must be verified on any electronic copies.
ELEVATED FIXTURE
DETAILS (SHEET 3
OF 3)
MAG
CB
MAG
E505
L-867 ONE PIECE BASE CAN
L-867 TELESCOPING BASE CAN
EXISTING L-868 ONE PIECE BASE CAN WITH
SPACER RINGS 2" ≥ 3"
L-867 TWO PIECE BASE CAN
EXISTING L-868 ONE PIECE BASE
CAN WITH SPACER RINGS ≤ 1"
EXISTING L-868 ONE PIECE BASE CAN WITH
SPACER RINGS 1" ≤ 2"
EXISTING L-868 ONE PIECE BASE
CAN WITH SPACER RINGS > 3"
EXISTING L-868 TWO PIECE BASE CAN
"SAFE" ADJUSTABLE BASE CAN
SEE PREPARATION OF BASE CAN FOR
MILL AND OVERLAY (SHEET 1 OF 5)
FOR APPLICABLE NOTES.
NOTE:
2024.199.05
DRAWING
FEBRUARY 2026
SS
NO. DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
REVISIONS:
TW P3 AND TW P4
IMPROVEMENTS
DAYTONA BEACH
INTERNATIONAL
AIRPORT
2419905034E506CADD
PROFESSIONAL SEAL
FDOT FM:
FAA AIP: XXXX
XXXX
ENGINEERS & PLANNERS
5555 E. MICHIGAN ST., SUITE 200 - ORLANDO, FL 32822-2779
OFFICE: (407) 599-1122 - FAX: (407) 599-1133 CORPORATE
CERTIFICATE OF AUTHORIZATION NUMBER: 5057
www.avconinc.com
AVCON PROJECT NO.
SHEET OF 60
B
ID
D O
C U
M
EN
TS
This item has been electronically signed and sealed by using an SHA-1 authentication code. Printed copies of this document are not considered signed and sealed and the SHA-1 authentication code must be verified on any electronic copies.
MILL AND OVERLAY
FIXTURE PREPERATION
SHEETS (SHEET 1 OF 2)
MAG
CB
MAG
E506
STEP 1
STEP 2 STEP 3
STEP 4 STEP 5
NOTES:
EXISTING DEEP BASE CAN WITH TOP CAN SECTION
AND/OR SPACER RINGS ≥ 3"
2024.199.05
DRAWING
FEBRUARY 2026
SS
NO. DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
REVISIONS:
TW P3 AND TW P4
IMPROVEMENTS
DAYTONA BEACH
INTERNATIONAL
AIRPORT
2419905035E507CADD
PROFESSIONAL SEAL
FDOT FM:
FAA AIP: XXXX
XXXX
ENGINEERS & PLANNERS
5555 E. MICHIGAN ST., SUITE 200 - ORLANDO, FL 32822-2779
OFFICE: (407) 599-1122 - FAX: (407) 599-1133 CORPORATE
CERTIFICATE OF AUTHORIZATION NUMBER: 5057
www.avconinc.com
AVCON PROJECT NO.
SHEET OF 60
B
ID
D O
C U
M
EN
TS
This item has been electronically signed and sealed by using an SHA-1 authentication code. Printed copies of this document are not considered signed and sealed and the SHA-1 authentication code must be verified on any electronic copies.
MILL AND OVERLAY
FIXTURE PREPERATION
SHEETS (SHEET 2 OF 2)
MAG
CB
MAG
E507
MANDATORY SIGN LOCATION DETAIL
ARROW ROTATION ANGLE DATA AS VIEWED
LOOKING AT SIGN FACE
2024.199.05
DRAWING
FEBRUARY 2026
SS
NO. DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
REVISIONS:
TW P3 AND TW P4
IMPROVEMENTS
DAYTONA BEACH
INTERNATIONAL
AIRPORT
2419905036E508CADD
PROFESSIONAL SEAL
FDOT FM:
FAA AIP: XXXX
XXXX
ENGINEERS & PLANNERS
5555 E. MICHIGAN ST., SUITE 200 - ORLANDO, FL 32822-2779
OFFICE: (407) 599-1122 - FAX: (407) 599-1133 CORPORATE
CERTIFICATE OF AUTHORIZATION NUMBER: 5057
www.avconinc.com
AVCON PROJECT NO.
SHEET OF 60
B
ID
D O
C U
M
EN
TS
This item has been electronically signed and sealed by using an SHA-1 authentication code. Printed copies of this document are not considered signed and sealed and the SHA-1 authentication code must be verified on any electronic copies.
SIGN SCHEDULE
(SHEET 1 OF 2)
MAG
CB
MAG
E508
SIGN SCHEDULE FOR GUIDANCE SIGNS ASSOCIATED WITH TAXIWAY "P3 & P4" WORK
P3
7L-25RP3
P4P3
P4
P4
7L-25R
P3
P3P
P4P
B1P
P4P
B2P
B1 P
PB1
B2 P
PB2
2024.199.05
DRAWING
FEBRUARY 2026
SS
NO. DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
REVISIONS:
TW P3 AND TW P4
IMPROVEMENTS
DAYTONA BEACH
INTERNATIONAL
AIRPORT
2419905037E509CADD
PROFESSIONAL SEAL
FDOT FM:
FAA AIP: XXXX
XXXX
ENGINEERS & PLANNERS
5555 E. MICHIGAN ST., SUITE 200 - ORLANDO, FL 32822-2779
OFFICE: (407) 599-1122 - FAX: (407) 599-1133 CORPORATE
CERTIFICATE OF AUTHORIZATION NUMBER: 5057
www.avconinc.com
AVCON PROJECT NO.
SHEET OF 60
B
ID
D O
C U
M
EN
TS
This item has been electronically signed and sealed by using an SHA-1 authentication code. Printed copies of this document are not considered signed and sealed and the SHA-1 authentication code must be verified on any electronic copies.
SIGN SCHEDULE
(SHEET 2 OF 2)
MAG
CB
MAG
E509
SECTION A-ARIGHT SIDE VIEW
DETAIL ''A''
DETAIL ''A1''
DETAIL ''B''
2024.199.05
DRAWING
FEBRUARY 2026
SS
NO. DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
REVISIONS:
TW P3 AND TW P4
IMPROVEMENTS
DAYTONA BEACH
INTERNATIONAL
AIRPORT
2419905038E510CADD
PROFESSIONAL SEAL
FDOT FM:
FAA AIP: XXXX
XXXX
ENGINEERS & PLANNERS
5555 E. MICHIGAN ST., SUITE 200 - ORLANDO, FL 32822-2779
OFFICE: (407) 599-1122 - FAX: (407) 599-1133 CORPORATE
CERTIFICATE OF AUTHORIZATION NUMBER: 5057
www.avconinc.com
AVCON PROJECT NO.
SHEET OF 60
B
ID
D O
C U
M
EN
TS
This item has been electronically signed and sealed by using an SHA-1 authentication code. Printed copies of this document are not considered signed and sealed and the SHA-1 authentication code must be verified on any electronic copies.
SIGN NOTES
MAG
CB
MAG
E510
TWO MODULE SIGN PLAN VIEW
N.T.S.
N.T.S.
TWO MODULE SIGN FRONT VIEW
NOTE **8
TO PAVEMENT
SEE SIGN DETAILS SHEET E510
FOR APPLICABLE NOTES.
NOTE:
GRADING AND FILL DETAIL
ADHESIVE I.D.
LABEL (TYP.)
4 0 5
MODE 1 & 2, 200 MPH (STANDARD)
CONFIGURATION MOUNTING DETAIL
A
A
SIGN
CENTERLINE
RIGHT SIDE VIEW
RW -
P P3
N.T.S.
SIGN INSTALLATION IN ASPHALT
2024.199.05
DRAWING
FEBRUARY 2026
SS
NO. DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
REVISIONS:
TW P3 AND TW P4
IMPROVEMENTS
DAYTONA BEACH
INTERNATIONAL
AIRPORT
2419905039E511CADD
PROFESSIONAL SEAL
FDOT FM:
FAA AIP: XXXX
XXXX
ENGINEERS & PLANNERS
5555 E. MICHIGAN ST., SUITE 200 - ORLANDO, FL 32822-2779
OFFICE: (407) 599-1122 - FAX: (407) 599-1133 CORPORATE
CERTIFICATE OF AUTHORIZATION NUMBER: 5057
www.avconinc.com
AVCON PROJECT NO.
SHEET OF 60
B
ID
D O
C U
M
EN
TS
This item has been electronically signed and sealed by using an SHA-1 authentication code. Printed copies of this document are not considered signed and sealed and the SHA-1 authentication code must be verified on any electronic copies.
SIGN DETAILS
(SHEET 1 OF 4)
MAG
CB
MAG
E511
THREE MODULE SIGN PLAN VIEW
THREE MODULE SIGN FRONT VIEW
SEE SIGN DETAILS SHEET E510
FOR APPLICABLE NOTES.
NOTE:
A
A
B1 P
2024.199.05
DRAWING
FEBRUARY 2026
SS
NO. DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
REVISIONS:
TW P3 AND TW P4
IMPROVEMENTS
DAYTONA BEACH
INTERNATIONAL
AIRPORT
2419905040E512CADD
PROFESSIONAL SEAL
FDOT FM:
FAA AIP: XXXX
XXXX
ENGINEERS & PLANNERS
5555 E. MICHIGAN ST., SUITE 200 - ORLANDO, FL 32822-2779
OFFICE: (407) 599-1122 - FAX: (407) 599-1133 CORPORATE
CERTIFICATE OF AUTHORIZATION NUMBER: 5057
www.avconinc.com
AVCON PROJECT NO.
SHEET OF 60
B
ID
D O
C U
M
EN
TS
This item has been electronically signed and sealed by using an SHA-1 authentication code. Printed copies of this document are not considered signed and sealed and the SHA-1 authentication code must be verified on any electronic copies.
SIGN DETAILS
(SHEET 2 OF 4)
MAG
CB
MAG
E512
FOUR MODULE SIGN PLAN VIEW
N.T.S.
N.T.S.
FOUR MODULE SIGN FRONT VIEW
TO PAVEMENT
LONGITUDINAL
CENTERLINE OF
SIGN
SEE SIGN DETAILS SHEET E510
FOR APPLICABLE NOTES.
NOTE:
A
A
7L -2 5RP3
2024.199.05
DRAWING
FEBRUARY 2026
SS
NO. DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
REVISIONS:
TW P3 AND TW P4
IMPROVEMENTS
DAYTONA BEACH
INTERNATIONAL
AIRPORT
2419905041E513CADD
PROFESSIONAL SEAL
FDOT FM:
FAA AIP: XXXX
XXXX
ENGINEERS & PLANNERS
5555 E. MICHIGAN ST., SUITE 200 - ORLANDO, FL 32822-2779
OFFICE: (407) 599-1122 - FAX: (407) 599-1133 CORPORATE
CERTIFICATE OF AUTHORIZATION NUMBER: 5057
www.avconinc.com
AVCON PROJECT NO.
SHEET OF 60
B
ID
D O
C U
M
EN
TS
This item has been electronically signed and sealed by using an SHA-1 authentication code. Printed copies of this document are not considered signed and sealed and the SHA-1 authentication code must be verified on any electronic copies.
SIGN DETAILS
(SHEET 3 OF 4)
MAG
CB
MAG
E513
MODE 3, 300 MPH (HIGH WIND) CONFIGURATION MOUNTING DETAIL
RDR SIGN PLAN VIEW
RDR SIGN FRONT VIEW
A
A
SEE SIGN DETAILS SHEET E510
FOR APPLICABLE NOTES.
NOTE:
2024.199.05
DRAWING
FEBRUARY 2026
SS
NO. DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
REVISIONS:
TW P3 AND TW P4
IMPROVEMENTS
DAYTONA BEACH
INTERNATIONAL
AIRPORT
2419905042E514CADD
PROFESSIONAL SEAL
FDOT FM:
FAA AIP: XXXX
XXXX
ENGINEERS & PLANNERS
5555 E. MICHIGAN ST., SUITE 200 - ORLANDO, FL 32822-2779
OFFICE: (407) 599-1122 - FAX: (407) 599-1133 CORPORATE
CERTIFICATE OF AUTHORIZATION NUMBER: 5057
www.avconinc.com
AVCON PROJECT NO.
SHEET OF 60
B
ID
D O
C U
M
EN
TS
This item has been electronically signed and sealed by using an SHA-1 authentication code. Printed copies of this document are not considered signed and sealed and the SHA-1 authentication code must be verified on any electronic copies.
SIGN DETAILS
(SHEET 4 OF 4)
MAG
CB
MAG
E514
GRAPHIC SCALE (FT)
1000500250
NORTH
GRAPHIC SCALE (FT)
20010050
NORTH
EXISTING SIGN LOCATION
WORK AREA
A
A
SECTION AA
GRADING
CIVIL NOTES: ELECTRICAL NOTES:
SECTION AA
CIRCUITING
DEMOLITION NOTES:
PROPOSED NOTES:
2024.199.05
DRAWING
FEBRUARY 2026
SS
NO. DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
REVISIONS:
TW P3 AND TW P4
IMPROVEMENTS
DAYTONA BEACH
INTERNATIONAL
AIRPORT
2419905043E515CADD
PROFESSIONAL SEAL
FDOT FM:
FAA AIP: XXXX
XXXX
ENGINEERS & PLANNERS
5555 E. MICHIGAN ST., SUITE 200 - ORLANDO, FL 32822-2779
OFFICE: (407) 599-1122 - FAX: (407) 599-1133 CORPORATE
CERTIFICATE OF AUTHORIZATION NUMBER: 5057
www.avconinc.com
AVCON PROJECT NO.
SHEET OF 60
B
ID
D O
C U
M
EN
TS
This item has been electronically signed and sealed by using an SHA-1 authentication code. Printed copies of this document are not considered signed and sealed and the SHA-1 authentication code must be verified on any electronic copies.
RELOCATING
EXISTING RDR SIGN
MAG
CB
MAG
E515
JUNCTION CAN PLAZA NUMBERING SYSTEM
SECTION A-AL-867D JUNCTION CAN PLAZA - 2 CAN
SHEET NOTES:
DETAIL ''B''
A E516
A E516
2024.199.05
DRAWING
FEBRUARY 2026
SS
NO. DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
REVISIONS:
TW P3 AND TW P4
IMPROVEMENTS
DAYTONA BEACH
INTERNATIONAL
AIRPORT
2419905044E516-E517CADD
PROFESSIONAL SEAL
FDOT FM:
FAA AIP: XXXX
XXXX
ENGINEERS & PLANNERS
5555 E. MICHIGAN ST., SUITE 200 - ORLANDO, FL 32822-2779
OFFICE: (407) 599-1122 - FAX: (407) 599-1133 CORPORATE
CERTIFICATE OF AUTHORIZATION NUMBER: 5057
www.avconinc.com
AVCON PROJECT NO.
SHEET OF 60
B
ID
D O
C U
M
EN
TS
This item has been electronically signed and sealed by using an SHA-1 authentication code.
This is the start of the file's text. The full file is on GovTribe.