Exhibit C SOW Site40_LLRW Roof Replacement_240913.pdf

PDF 174 KB Posted

Attached to
Fermilab - Removal and replacement of roofing systems
Solicitation number
ISD-356855-RK
Issued by

About this file

This document is a Statement of Work (SOW) for a federal contract opportunity issued by the Fermi National Accelerator Laboratory (FNAL) for the removal and replacement of roofing systems on an existing building at the FNAL site in Batavia, Illinois.

The SOW requires the subcontractor to furnish all supervision, labor, materials, tools, and equipment necessary to remove and dispose of the existing roofing and insulation down to the bare roof decking, and replace it with a new SBS Asphalt 4CID CR G roofing system. The work also includes the relocation and reinstallation of existing roof equipment, removal and replacement of all roofing trim, fascia, gravel stops, and coping, as well as the installation of a new ballasted roof edge railing system. The project has a total duration of 75 calendar days from the Notice to Proceed (NTP), with key milestones at 0 days (NTP), 20 days (all material submittals), and 75 days (project completion). The subcontractor is responsible for all quality assurance activities, and no government-furnished property is anticipated for this project.

View the file

Other files

File Type Posted
Amendment No. 1 Fermilab Removal Systems.pdf PDF
Exhibit T 10-4-101_Site 40 LLRW_V2024_Roof-G02-REV1.pdf PDF
Exhibit S Request For Clarifications v1.pdf PDF
Exhibit 1- REQUEST FOR PROPOSAL (RFP) INSTRUCTIONS TO OFFERORS Roof Replacement_Site40 v2.pdf PDF
Exhibit Q 10-4-101_Site 40 LLRW_Roof Replacement drawing set_240913.pdf PDF
Exhibit D FL-41 (Rev 12.22) - Bid Bond.pdf PDF
Exhibit M Site40_013100_ESH_Requirements_3-2022.pdf PDF
Exhibit F Performance Bond FL-40 (Rev 12.22).pdf PDF
Exhibit G Fermilab Subcontractor Safety Information Questionnaire.pdf PDF
Exhibit I Proposal Certifications Form PUR 466 Rev. 1 (10142021).pdf PDF
Exhibit R Proposal Form.pdf PDF
Exhibit N Site 40 013300 Submittals 240913.pdf PDF
Exhibit O Sample Subcontract.pdf PDF
Exhibit P Wage Determinations.pdf PDF
Exhibit J Subcontractor Annual Representations Certifications (SARC) Form SARC (Rev. 3) (04082022).pdf PDF
Exhibit H Statement and Acknowledgment (Standard Form 1413) (Rev 42013).pdf PDF
Exhibit A FRA General Terms and Conditions for Construction (03.2024).pdf PDF
Exhibit B 2022 Construction Insurance Requirements.pdf PDF
Exhibit E Payment Bond FL 42 (Rev 12.22).pdf PDF
Exhibit K FAR 52-219-9-Small-Business-Subcontracting-Plan-.pdf PDF
Exhibit L Site40 010010_General_Requirements_3_2022_240913.pdf PDF
Show all 21

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Statement of Work (SOW) –

SITE 40 LOW LEVEL WASTE HANDLING BUILDING

September 13, 2024

1.0 INTRODUCTION AND BACKGROUND

Fermi National Accelerator Laboratory (FNAL) is requesting a proposal for removal and replacement of roofing systems; one low roof and one high bay roof, at one existing building.

The project is located on the Fermi National Accelerator Laboratory (Fermilab) Site, adjacent to the city of

Batavia, Illinois. The project is in DuPage County, located on West Batavia Road, and East of Receiving

Road. Refer to sheet G-01 of drawing set for vicinity map.

2.0 SCOPE OF WORK:

The Subcontractor shall furnish all required supervision, labor materials, tools, plant, and appurtenances necessary to perform diligently and fully all work as described in the drawings and technical specifications.

All work includes transportation, overhead, bonding costs, safety oversight, quality control oversight, and supervision as required to construct the project described in the drawings and technical specifications.

Work will include:

A. Furnish all labor, materials and equipment required to remove and dispose of existing roofing and insulation down to bare roof decking. Replace with new SBS Asphalt 4CID CR G roofing systems, including miscellaneous associated work as described in the drawing set "10-4-101_Site 40

LLRW_CCR_RoofReplacement_200321.pdf”; ISD project number 10-4-101; dated 09/13/24.

B. Provide all associated work including but not limited to relocation and reinstallation of existing roof equipment; removal and replacement of all roofing trim, fascia, gravel stops and coping.

C. Furnish all labor, materials and equipment required for new ballasted roof edge railing system as described in the drawing set.

3.0 Deliverables

The Subcontractor shall perform all work required to complete the construction work in accordance with the drawings and/or specifications.

4.0 Quality Assurance

A Fermilab Construction Coordinator will be assigned to this project. Refer to Specification section

010010, GENERAL REQUIREMENTS.

The Subcontractor is responsible for all activities necessary to manage, control, and document that work complies with the Subcontract documents. The Subcontractor’s responsibility includes ensuring adequate Quality Control services are provided for work accomplished on- and off-site by his/her organization, suppliers, sub-tier contractors, technical laboratories, and consultants.

5.0 Government - Furnished Property

No roofing materials and equipment necessary for completion are anticipated to be furnished for this project by FRA.

6.0 Security

All personnel working at Fermilab are required to provide Real ID and obtain badging from the

Fermilab Badging Office.

Compliance with the Fermilab COVID 19 requirements in effect at the time the work is performed is mandatory

7.0 Schedule/ Period of Performance

This project includes the following milestones:

1. Milestone 0: 0 Calendar Days- NTP.

a. This milestone marks the point where construction work may begin.

2. Milestone 1: 20 Calendar Days – All Material Submittals

a. The Notice To Proceed (NTP) represents the basis of the start of the project duration.

3. Milestone 2: 75 Calendar Days – Project Complete

a. The Project Complete milestone marks the completion of the project including punchlist items, clean-up and acceptance of as-built drawings and if required, submittals.

Encl:

10-4-101_Site 40 LLRW_Roof Replacement drawing set_240913.pdf

Site40 013100_ESH_Requirements_3-2022.docx

Site 40 013300 Submittals_240913.docx

Site40 010010_General_Requirements_3_2022_240913 .docx

File details come from the government source that posted it. Updated .