EXHIBIT C - SAMPLE FLOOR PLANS W SAFE ROOMS (1).pdf
PDF 4 MB Posted
- Attached to
- 1411-26-R-RFQF-00001
- Solicitation number
- 3140004602
- Issued by
- Simpson County, Mississippi
About this file
This document is a sample floor plan exhibit prepared by Cobalt Engineering and Inspections, LLC for the Mississippi Development Authority (MDA) CDBG-DR Residential Reconstruction and Rehabilitation Services program. The file contains comprehensive architectural and engineering drawings for two residential housing options: the "Nebula" model featuring 800 square feet of living space with two bedrooms, one bathroom, and covered porches; and the "Hubble" model comprising 899 square feet with three bedrooms, one bathroom, and covered outdoor areas. Both designs include detailed roof plans with 5:12 slope, floor plans with room-by-room square footage calculations, exterior elevations, and comprehensive mechanical, electrical, and plumbing systems. The plans specify window and door schedules with sound transmission class (STC) ratings of 40 or higher, 30-year architectural shingles, fiber cement siding, and flood-resistant materials compliant with FEMA Technical Bulletin 2. Additionally, the drawings include safe room specifications sized at 5x7 and 7x7 feet constructed with concrete masonry units on concrete slabs and steel roofs, designed to be compliant with FEMA 361 and ICC-500-2023 standards.
The architectural drawings are identified as conceptual plans not intended for site-specific permitting purposes, with the notation that site-specific plans shall be prepared on a case-by-case basis. The designs specify attic ventilation calculations, foundation and ceiling joist plans with 2x6 joists at 16-inch spacing, rafter plans with 2x6 rafters at 16-inch centers, and shear wall configurations meeting structural requirements. Electrical plans include GFCI receptacles at 18, 42, and 48 inches above finished floor, 220-volt circuits for appliances with minimum 30-50 amp ratings, and provisions for future 240-volt use. Plumbing systems incorporate 3-inch and 4-inch sanitary lines with exterior cleanouts, 2-inch vent pipes, and hot and cold water distribution throughout. HVAC plans specify air handlers in the attic with flex duct (R-8 minimum) and rectangular duct systems. The document carries a validity date of one year from the signature date and includes the engineering firm's contact information: phone 409-354-5925 and email info@cobalt-engineering.com.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
01 ROOF PLAN (STANDARD) 02 FLOOR PLAN (STANDARD)
OPTION 1 OPTION 1
*SEE FLOOR PLAN FOR KITCHEN
AND LAUNDRY ROOM VENTING
NOTE: ALL WINDOWS AND DOORS TO HAVE A STC RATING OF 40 OR HIGHER
D
W
WH
5:12
SLOPE
5:12
SLOPE
5:12
SLOPE
5:12
SLOPE
5:
S
LO
PE
1'-4" TYP.
EXHAUST VENT W/
DAMPER & CAP
SQUARE FOOTAGE CALCULATIONS
LOCATION SQUARE FOOTAGE REMARKS
FLOOR PLAN 800 SQFT
FRONT PORCH 100 SQFT
REAR PORCH 25 SQFT
WINDOW SCHEDULE
MARK QUANTITY DESCRIPTIONS REMARKS
A 3 3'-0" X 5'-0" SINGLE HUNG
B 2 3'-0" X 3'-0" SINGLE HUNG
DOOR SCHEDULE
MARK QTY DESCRIPTIONS REMARKS
01 2 3'-0" X 6'-8" EXTERIOR WITH PEEPHOLE
02 4 3'-0" X 6'-8" INTERIOR
03 1 2'-6" X 6'-8" INTERIOR
04 2 (2) 2'-0" X 6'-8" DOUBLE DOORS
05 3 3'-0" X 6'-8" VENTED
06 1 2'-8" X 6'-8" INTERIOR
07 1 22" X 30" ATTIC ACCESS 350 POUND LADDER RATING
08 1 3'-0" X 6'-8" EXTERIOR
6'-10"2'-0"5'-2"
3'-4 1/2"5'-3"6'-2"5'-3"3'-4 1/2" 23'-5"
AA
5'-2"
FRONT
PORCH
100 S.F.
4'-3"
4' -9
'-1
0"
B
'-3
/2
5'
-6
/2
KITCHEN
103 S.F.
9' CLG.
SI
N
K D
W
R
AN
G E
R
EF
05A/C
AT
TI
C
AC
C
ES
S07
PA
N
TR
Y
3' -1
0"
3'-8"
4' -4
2' -3
6'
-5
3' -0
2'
-4
9' -8
6'-4"5'-4"
BATH
64 S.F.
9' CLG.
LIVING ROOM
126 S.F.
9' CLG.
CLO. 7 S.F.
BEDROOM 1
111 S.F.
9' CLG.
4'-4"3'-4"4'-0"
2X8 WALL
CLO. 11 S.F.
2X6 WALL
5'-3" 2'-5"
NOTE: ALL CABINET
DIMENSIONS ARE TO
BE FIELD VERIFIED
AND ARE THE
RESPONSIBILITY OF
THE CONTRACTOR
11'-8"4'-6"2'-0 1/2"
'-2
6' -0
'-6
BEDROOM 2
112 S.F.
9' CLG.
LAUNDRY
18 S.F.
9' CLG.
3' -1
0"
REAR
PORCH
25 S.F.
A
5'-2 1/2"
5'-7"
3' -1
0" 6'
-6
B
3' -3
/2
3'
-1
/2
5:12
SLOPE
5:12
SLOPE
6'-1"
DINNER
46 S.F.
9' CLG.
4'-3 1/2" 4'-1 1/2"
Revisions:
PROJECT LOCATION OR ADDRESS:
CLIENT:
# DATE DESCRIPTION OF CHANGE
CHECKED BY:
SCALE:
DRAWN BY:
PROJECT #:
DATE:
CCH
NOTE: SIGNATURES VALID FOR ONE YEAR ONLY AFTER DATE OF SIGNATURES
ALL RIGHTS RESERVED. NO PART OF THIS DOCUMENT MAY BE REPRODUCED OR
UTILIZED IN ANY FORM WITHOUT PRIOR WRITTEN AUTHORIZATION OF “COBALT”.
CLIENT
ADDRESS
XXXXXXXX,TX 77XXX
XX-XXXX-XX
0 ISSUED FOR CONSTRUCTION
XX-XXXX-HRAP-ASH-SOG-XX/XX/2023
XX/XX/2023
THIS DRAWING IS A CONCEPTUAL PLAN AND IS NOT
INTENDED TO BE USED AS A SITE SPECIFIC PLAN NOR
SHALL IT BE USED FOR PERMITTING PURPOSES. SITE
SPECIFICS SHALL BE PREPARED ON A CASE-BY-CASE
BASIS AND ANY USE BEYOND THE AFOREMENTIONED
INTENT IS PROHIBITED.
® phone: 409-354-5925 email: info@cobalt-engineering.com
ENGINEERING AND INSPECTIONS, LLC
1/4" = 1'-0"
A-1.00
NEBULA
FLOOR PLAN - ROOF PLAN
OPTION 1 (STANDARD)
DAS
NOTES
1. WHEN REQUIRED SEE SHEET C-1.00 FOR LAYOUT
AND LOCATION OF RAMP AND STAIRS
2. WHEN REQUIRED SEE SHEET SD-4.00 FOR RAMP
AND STAIR DETAILS
3. ROOF OVERHANG SHALL BE A MINIMUM OF 18
INCHES (INCLUDING GUTTERS) BEYOND THE
OUTTER MOST PORTION IF ANY EXTERIOR
VENEER. CONTRACTOR TO ADJUST RAFTER
TAILS AS REQUIRED.
4. WINDOWS USED FOR EGRESS SHALL HAVE A NET
CLEAR OPENING OF NOT LESS THAN 5.7 S.F.
WITH A MINIMUM HEIGHT OF 24" AND A MINIMUM
WIDTH OF 20" PER THE INTERNATIONAL
RESIDENTIAL CODE.
5. PLAIN HALF-ROUND 6" WIDE AND 4" DIAMETER
DOWNSPOUT, MINIMUM 22-GAUGE GALVANIZED
STEEL, PREFINISHED. OR STANDARD K-STYLE 6"
WIDE AND 3"X4" DOWNSPOUT, MINIMUM
22-GAUGE GALVANIZED STEEL, PREFINISHED.
6. ALL DOWNSPOUTS TO HAVE SPLASH BLOCK.
7. SMART VENT (1540-510) FLOOD VENTS ARE
REQUIRED WHEN ENCLOSED SPACE IS BELOW
B.F.E. IN AN "A" FLOOD ZONE.
8. FEMA APPROVED BREAKAWAY WALLS OR
LOUVERS ARE REQUIRED WHEN ENCLOSED
SPACE IS BELOW B.F.E. IN A "V" FLOOD ZONE.
9. ALL MATERIALS BELOW BFE AND/OR DFE SHALL
BE FLOOD RESISTANT MATERIAL INCLUDING, BUT
NOT LIMITED TO TREATED FRAMING MATERIAL.
SEE FEMA TECHNICAL BULLETIN 2, FLOOD
DAMAGE RESISTANT MATERIALS REQUIREMENTS
(2008).
10. RAIN DIVERTER STRIP IS REQUIRED OVER A/C
UNIT AND ENTRANCES.
THE ATTIC ACCESS IS REQUIRED TO BE A MINIMUM
OF 22”X30”, ASSUMING THAT NO EQUIPMENT WILL BE
INSTALLED IN THE ATTIC SPACE. IT IS THE
RESPONSIBILITY OF THE GENERAL CONTRACTOR TO
CONFIRM SITE SPECIFIC REQUIREMENTS.”
11. SEE STRUCTURAL FOUNDATION PLAN FOR
FLATWORK DIMENSIONS.
12. SEE SITE PLAN SHEET C-1.00 FOR EXTERIOR A/C
LOCATION.
ATTIC VENTILATION CALCULATION
AREA SQUARE FOOTAGE
TOTAL AREA 989 S.F.
TOTAL REQUIRED VENTED AREA (1/150) 6.59 S.F.
REQUIRED RIDGE (HIP) VENTILATION 3.29
REQUIRED SOFFIT VENTILATION 3.29
9' -0
A A
PLATE HEIGHT 2'
-3
2'
-1 0"
APPROX. HEIGHT
APPROX. HEIGHT
9' -0
PLATE HEIGHT
5' -1
APPROX. HEIGHT
9' -0
PLATE HEIGHT
5' -1
APPROX. HEIGHT
9' -0
PLATE HEIGHT
5' -1
APPROX. HEIGHT
01 FRONT ELEVATION (STANDARD)
SCALE: 1/4" = 1'-0"
02 LEFT ELEVATION (STANDARD)
SCALE: 1/4" = 1'-0"
03 REAR ELEVATION (STANDARD)
SCALE: 1/4" = 1'-0"
04 RIGHT ELEVATION (STANDARD)
SCALE: 1/4" = 1'-0"
POST
FIBER
CEMENT
SIDING
TRIM
RIDGE VENT
30-YEAR
ARCHITECTURAL
SHINGLE
RIDGE VENT
30-YEAR
ARCHITECTURAL
SHINGLE
FIBER
CEMENT
SIDING
TRIM
TRIM
FIBER
CEMENT
SIDING
FIBER
CEMENT
SIDING
TRIM
POST
B
F.F.E. = +6" A.G. MIN.
NATURAL GRADE
NATURAL GRADE
F.F.E. = +6" A.G. MIN.
NATURAL GRADE
F.F.E. = +6" A.G. MIN.
NATURAL GRADE
BA
F.F.E. = +6" A.G. MIN.
Revisions:
PROJECT LOCATION OR ADDRESS:
CLIENT:
# DATE DESCRIPTION OF CHANGE
CHECKED BY:
SCALE:
DRAWN BY:
PROJECT #:
DATE:
CCH
NOTE: SIGNATURES VALID FOR ONE YEAR ONLY AFTER DATE OF SIGNATURES
ALL RIGHTS RESERVED. NO PART OF THIS DOCUMENT MAY BE REPRODUCED OR
UTILIZED IN ANY FORM WITHOUT PRIOR WRITTEN AUTHORIZATION OF “COBALT”.
CLIENT
ADDRESS
XXXXXXXX,TX 77XXX
XX-XXXX-XX
0 ISSUED FOR CONSTRUCTION
XX-XXXX-HRAP-ASH-SOG-XX/XX/2023
XX/XX/2023
THIS DRAWING IS A CONCEPTUAL PLAN AND IS NOT
INTENDED TO BE USED AS A SITE SPECIFIC PLAN NOR
SHALL IT BE USED FOR PERMITTING PURPOSES. SITE
SPECIFICS SHALL BE PREPARED ON A CASE-BY-CASE
BASIS AND ANY USE BEYOND THE AFOREMENTIONED
INTENT IS PROHIBITED.
® phone: 409-354-5925 email: info@cobalt-engineering.com
ENGINEERING AND INSPECTIONS, LLC
1/4" = 1'-0"
A-2.00
NEBULA
EXTERIOR ELEVATIONS
OPTION 1 (STANDARD)
DAS
NOTES
1. WHEN REQUIRED SEE SHEET C-1.00 FOR LAYOUT
AND LOCATION OF RAMP AND STAIRS
2. WHEN REQUIRED SEE SHEET SD-4.00 FOR RAMP
AND STAIR DETAILS
3. ROOF OVERHANG SHALL BE A MINIMUM OF 18
INCHES (INCLUDING GUTTERS) BEYOND THE
OUTTER MOST PORTION IF ANY EXTERIOR
VENEER. CONTRACTOR TO ADJUST RAFTER
TAILS AS REQUIRED.
4. WINDOWS USED FOR EGRESS SHALL HAVE A NET
CLEAR OPENING OF NOT LESS THAN 5.7 S.F.
WITH A MINIMUM HEIGHT OF 24" AND A MINIMUM
WIDTH OF 20" PER THE INTERNATIONAL
RESIDENTIAL CODE.
5. PLAIN HALF-ROUND 6" WIDE AND 4" DIAMETER
DOWNSPOUT, MINIMUM 22-GAUGE GALVANIZED
STEEL, PREFINISHED. OR STANDARD K-STYLE 6"
WIDE AND 3"X4" DOWNSPOUT, MINIMUM
22-GAUGE GALVANIZED STEEL, PREFINISHED.
6. ALL DOWNSPOUTS TO HAVE SPLASH BLOCK.
7. SMART VENT (1540-510) FLOOD VENTS ARE
REQUIRED WHEN ENCLOSED SPACE IS BELOW
B.F.E. IN AN "A" FLOOD ZONE.
8. FEMA APPROVED BREAKAWAY WALLS OR
LOUVERS ARE REQUIRED WHEN ENCLOSED
SPACE IS BELOW B.F.E. IN A "V" FLOOD ZONE.
9. ALL MATERIALS BELOW BFE AND/OR DFE SHALL
BE FLOOD RESISTANT MATERIAL INCLUDING, BUT
NOT LIMITED TO TREATED FRAMING MATERIAL.
SEE FEMA TECHNICAL BULLETIN 2, FLOOD
DAMAGE RESISTANT MATERIALS REQUIREMENTS
(2008).
10. RAIN DIVERTER STRIP IS REQUIRED OVER A/C
UNIT AND ENTRANCES.
THE ATTIC ACCESS IS REQUIRED TO BE A MINIMUM
OF 22”X30”, ASSUMING THAT NO EQUIPMENT WILL BE
INSTALLED IN THE ATTIC SPACE. IT IS THE
RESPONSIBILITY OF THE GENERAL CONTRACTOR TO
CONFIRM SITE SPECIFIC REQUIREMENTS.”
11. SEE STRUCTURAL FOUNDATION PLAN FOR
FLATWORK DIMENSIONS.
03 ELECTRICAL PLAN (STANDARD)
ALL OPTIONS
03 WINDOW FLNEBULAING DETAIL
ALL OPTIONS
NOTE: WHEN GAS DRYER IS USED, A DEDICATED 240-VOLD BRANCH
CIRCUIT WITHIN 3 FEET OF THE DRYER IS TO BE USED. THIS CIRCUIT
SHALL HAVE A MINIMUM 30 AMP RATING. WHEN GAS RANGE IS USED, A
DEDICATED 240-VOLD BRANCH CIRCUIT IS TO BE USED. THIS CIRCUIT
SHALL HAVE A MINIMUM 50 AMP RATING. THE MAIN ELECTRICAL SERVICE
SHALL HAVE A RESERVED SPACE TO ALLOW FOR THE INSTALLATION OF A
DOUBLE POLE CIRCUIT BREAKER. THE RESERVED SPACE SHALL BE
PERMANENTLY MARKED "FOR FUTURE 240V USE".
EF
CD
OD OD
GFI 220V
GFI 72" AFF
W/P GFI
GFI 18" AFF
(FOOD DISPOSAL)
GFI 18" AFF
(DISHWNEBULAER)
GFI 42" AFF
CD
SD
SD
GFI 42" AFF
BREAKER
BOX 48" AFF GFI
220V
GFI
OD
GFI 48" AFF
Revisions:
PROJECT LOCATION OR ADDRESS:
CLIENT:
# DATE DESCRIPTION OF CHANGE
CHECKED BY:
SCALE:
DRAWN BY:
PROJECT #:
DATE:
CCH
NOTE: SIGNATURES VALID FOR ONE YEAR ONLY AFTER DATE OF SIGNATURES
ALL RIGHTS RESERVED. NO PART OF THIS DOCUMENT MAY BE REPRODUCED OR
UTILIZED IN ANY FORM WITHOUT PRIOR WRITTEN AUTHORIZATION OF “COBALT”.
CLIENT
ADDRESS
XXXXXXXX,TX 77XXX
XX-XXXX-XX
0 ISSUED FOR CONSTRUCTION
XX-XXXX-HRAP-ASH-SOG-XX/XX/2023
XX/XX/2023
THIS DRAWING IS A CONCEPTUAL PLAN AND IS NOT
INTENDED TO BE USED AS A SITE SPECIFIC PLAN NOR
SHALL IT BE USED FOR PERMITTING PURPOSES. SITE
SPECIFICS SHALL BE PREPARED ON A CASE-BY-CASE
BASIS AND ANY USE BEYOND THE AFOREMENTIONED
INTENT IS PROHIBITED.
® phone: 409-354-5925 email: info@cobalt-engineering.com
ENGINEERING AND INSPECTIONS, LLC
NEBULA
ELECTRICAL PLAN AND SECTIONS
ALL OPTIONS (STANDARD)
N.T.S.
A-3.00
DAS
LEGEND
CEILING FAN W/ LIGHT KIT
SURFACE MOUNTED LIGHT FIXTURE
55 CFM EXHAUST FAN / LIGHT
OUTDOOR SCONCE
SWITCH
STANDARD AFCI RECEPTACLE
220V RECEPTACLE
RECEPTACLE WITH GROUND FAULT
INTERCEPT
WATERPROOF WITH GROUND FAULT
INTERCEPT
OVERHEAD RECEPTACLE
RECESSED CAN LIGHT
SMOKE DETECTOR
COMBO SMOKE / CARBON MONOXIDE
DETECTOR
CHANDELIER
TV / PHONE JACK
HOT / COLD WATER SUPPLY
HOSE BIB
EXHAUST VENT
EF
OD
HB
WP
GFCI
OH
GFCI
SD
CD
NOTES
1. MAIN PANEL TO HAVE A MAIN
BREAKER/DISCONNECT AND SURGE
PROTECTOR
2. 110V RECEPTACLE TO BE WITHIN 25' OF
EXTERIOR AIR COMPRESSOR
PROVIDE ONE 110V, WEATHER PROTECTED GFCI OUTLET
WITHIN 25' OF OUTSIDE HEATING/COOLING EQUIPMENT.
PLUMBING LEGEND
3" MAIN SANITARY LINE, PROVIDE CLEAN OUT AT
EXTERIOR OF HOUSE
2" VENT PIPE
3" SANITARY TO TOILET
2" SANITARY AT SINK AND SHOWER
3" SANITARY AT WNEBULAER
4" SANITARY FROM CITY TO HOUSE
WNEBULAER & SINK RISER DETAILS
02 PLUMBING PLAN (STANDARD)
ALL OPTIONS
01 PLUMBING PLAN (STANDARD)
ALL OPTIONS
NOT TO SCALE
CLEAN OUT
CONNECT TO CITY FIELD
VERIFY
6WYE CLEAN OUT 3' FROM
PROPERTY LINE
2"Ø HW DW
2"Ø CW DW
2"Ø HW DW
2"Ø CW DW
2"Ø HW DW
2"Ø CW DW
2"Ø CW DW
2"Ø HW DW
2"Ø CW DW
2"Ø CW DW
HB
4"Ø CW
4"Ø CW
4"Ø CW
4"Ø CW
4"Ø CW
4"Ø CW
4"Ø HW DW
4"Ø HW DW
4"Ø HW DW
4"Ø HW DW
4"Ø HW DW
4"Ø UNIT SUPPLY,
FIELD VERIFY LOCATION
& DIAMETER
Revisions:
PROJECT LOCATION OR ADDRESS:
CLIENT:
# DATE DESCRIPTION OF CHANGE
CHECKED BY:
SCALE:
DRAWN BY:
PROJECT #:
DATE:
CCH
NOTE: SIGNATURES VALID FOR ONE YEAR ONLY AFTER DATE OF SIGNATURES
ALL RIGHTS RESERVED. NO PART OF THIS DOCUMENT MAY BE REPRODUCED OR
UTILIZED IN ANY FORM WITHOUT PRIOR WRITTEN AUTHORIZATION OF “COBALT”.
CLIENT
ADDRESS
XXXXXXXX,TX 77XXX
XX-XXXX-XX
0 ISSUED FOR CONSTRUCTION
XX-XXXX-HRAP-ASH-SOG-XX/XX/2023
XX/XX/2023
THIS DRAWING IS A CONCEPTUAL PLAN AND IS NOT
INTENDED TO BE USED AS A SITE SPECIFIC PLAN NOR
SHALL IT BE USED FOR PERMITTING PURPOSES. SITE
SPECIFICS SHALL BE PREPARED ON A CASE-BY-CASE
BASIS AND ANY USE BEYOND THE AFOREMENTIONED
INTENT IS PROHIBITED.
® phone: 409-354-5925 email: info@cobalt-engineering.com
ENGINEERING AND INSPECTIONS, LLC
A-4.00
NEBULA
PLUMBING PLAN
(STANDARD)
DAS
LEGEND
NOTES
1. THIS DRAWING IS INTENDED FOR
USE AS A RECOMMENDED
LAYOUT. THE GENERAL
CONTRACTOR IS RESPONSIBLE
FOR MEETING WITH APPLICABLE
CODE.
2. EXHAUST FANS SHALL VENT
DIRECTLY TO THE OUTSIDE AND
BE LOCATED IN ACCORDANCE
WITH SECTIONS R303.5.1 AND
R303.5.2 OF THE INTERNATIONAL
RESIDENTIAL CODE.
3. ALL HOSE CONNECTIONS SHALL
BE EQUIPPED WITH
NON-REMOVABLE BACK FLOW
PREVENTERS PER IRC 603.3.3.
4. CLEANOUT REQUIRED ABOVE
FLOOR LEVEL OF LOWEST FLOOR
OF BUILDING FOR KITCHEN SINK.
AND IS TO BE ON THE OUTSIDE
WALL.
5. MINIMUM 30" X 22" RETURN AIR
GRILLE.
6. MECHANICAL DRAIN LINES
CANNOT CONNECT TO PLUMBING
SYSTEM.
HOSE BIB
EXHAUST VENT
HB
03 HVAC PLAN (STANDARD)
AIR HANDLER
IN ATTIC
Revisions:
PROJECT LOCATION OR ADDRESS:
CLIENT:
# DATE DESCRIPTION OF CHANGE
CHECKED BY:
SCALE:
DRAWN BY:
PROJECT #:
DATE:
CCH
NOTE: SIGNATURES VALID FOR ONE YEAR ONLY AFTER DATE OF SIGNATURES
ALL RIGHTS RESERVED. NO PART OF THIS DOCUMENT MAY BE REPRODUCED OR
UTILIZED IN ANY FORM WITHOUT PRIOR WRITTEN AUTHORIZATION OF “COBALT”.
CLIENT
ADDRESS
XXXXXXXX,TX 77XXX
XX-XXXX-XX
0 ISSUED FOR CONSTRUCTION
XX-XXXX-HRAP-ASH-SOG-XX/XX/2023
XX/XX/2023
THIS DRAWING IS A CONCEPTUAL PLAN AND IS NOT
INTENDED TO BE USED AS A SITE SPECIFIC PLAN NOR
SHALL IT BE USED FOR PERMITTING PURPOSES. SITE
SPECIFICS SHALL BE PREPARED ON A CASE-BY-CASE
BASIS AND ANY USE BEYOND THE AFOREMENTIONED
INTENT IS PROHIBITED.
® phone: 409-354-5925 email: info@cobalt-engineering.com
ENGINEERING AND INSPECTIONS, LLC
A-5.00
NEBULA
HVAC PLAN
(STANDARD)
DAS
EXHAUST FAN
SUPPLY AIR REGISTER
FLEX DUCT (R-8 MIN.)
RECTANGULAR DUCT (R-8 MIN.)
LEGEND
NOTES
1. THIS DRAWING IS INTENDED FOR
USE AS A RECOMMENDED
LAYOUT. THE GENERAL
CONTRACTOR IS RESPONSIBLE
FOR MEETING WITH APPLICABLE
CODE.
2. EXHAUST FANS SHALL VENT
DIRECTLY TO THE OUTSIDE AND
BE LOCATED IN ACCORDANCE
WITH SECTIONS R303.5.1 AND
R303.5.2 OF THE INTERNATIONAL
RESIDENTIAL CODE.
3. ALL HOSE CONNECTIONS SHALL
BE EQUIPPED WITH
NON-REMOVABLE BACK FLOW
PREVENTERS PER IRC 603.3.3.
4. CLEANOUT REQUIRED ABOVE
FLOOR LEVEL OF LOWEST FLOOR
OF BUILDING FOR KITCHEN SINK.
AND IS TO BE ON THE OUTSIDE
WALL.
5. MINIMUM 30" X 22" RETURN AIR
GRILLE.
6. MECHANICAL DRAIN LINES
CANNOT CONNECT TO PLUMBING
SYSTEM.
A F-1.00
4" THK. 3000 P.S.I. CONC. SLAB
W/ 6X6 #10 W.W.M. OVER
TREATED, COMPACTED FILL W/
10 MIL. VAPOR BARRIER @
INTERIOR LOCATIONS (U.N.O.)
HUB DRAIN
4' -2
/4
11'-9 1/2"
10'-6"
7' -3
/2
6'-1"
2'-0 1/4"
3'-0"
'-4
/4
"19 '-1
1/
2"
'-2
/4
A F-
1.
SL
O
PE
0" D
R O
P
0' -3
6' -3
'-2
'-1
8'-8 1/2"
'-1
1/
2"
HUB DRAIN0'-3"
A F-1.00
A F-
1.
SL
O
PE
3'-4 1/2" 5'-6" 6'-2" 5'-0" 3'-7 1/2"
0'-3"
A F-1.00
'-2
6'
-3
4'-8" 11'-8 1/2"
SL
O
PE
6X6 POST TO FND
WITH ABU66Z
POST BASE
F-1.00
23'-8"
0' -3
5' -0
5'-0" 7'-0 1/2"
0'-3"
'-5
'-5
ATTIC ACCESS
THIS DWG.
CORNER PORCH
POST DETAIL (TYP.)
02/SD-1.00
BEAM POCKET
(TYP. 2 PLCS.)
(2 )2
X1
D R
O P
BE
AM
(2 )2
X1
D R
O P
BE
AM
3'-4 1/2"5'-3"3'-4 1/2" 6'-2" 5'-3"
8'-5" 3'-4" 11'-8"
23'-5"
6' -0
'-1 0"
3' -1
0" 6'
-6
'-2
9' -4
6'
-0
2' -4
3'
-0
6' -3
2'
-5
'-1
0"
(2)2X10 DROP BEAM
4'-6"
(2)2X10 DROP
BEAM
(2 )2
X1
D R
O P
BE
AM
4' -9
(2 )2
X1
D R
O P
BE
AM
LEGEND
NOTES
CEILING FRAMING:
1. ALL CEILING JOISTS SHALL BE 2X6 16" O.C.
(U.N.O.)
2. ATTIC ACCESS SHALL BE NO LESS THAN
350LB CAPACITY FOLDING STAIR SYSTEM.
X
XX
---- DETAIL
---- PAGE #
FRAMING:
1. ALL STUDS, FLOOR JOISTS, RAFTERS, TRUSS,
ETC. SHALL VERTICALLY ALIGN AND BEAR
DIRECTLY ON EACH OTHER.
FULL HEIGHT BLOCKING
TYPICAL STRONG BACK SEE
DETL. #3 ON DWG. SD-2.00
PONY WALL EXTENDED
TO ROOF DIAPHRAGM
CONCRETE HOLD-DOWNS:
1. SEE DRAWING S-2.00 FOR TYPE OF
HOLD-DOWN REQUIRED.
2. SEE DRAWING F-1.00 FOR HOLD-DOWN
INSTALLATION DETAIL. (REFER TO
MANUFACTURERS INSTALLATION
INSTRUCTIONS FOR ADDITIONAL REQ'S.)
HEADER FRAMING:
1. REFER TO DETAIL 1 ON SD-1.00 FOR ALL
HEADER REQUIREMENTS. (U.N.O.)
2. POCKET DOOR HEADERS SHALL SPAN THE
OPENING & THE DOOR CAVITY (TYPICAL)
STUD PACK FRAMING:
1. (4) 2X STUD PACK UNDER EACH END OF 2X
SOLID SAWN BEAM.
2. (6) 2X STUD PACK UNDER EACH END OF
GLULAM BEAM. (SEE PLAN FOR BEAM SIZE)
3000Fb ANTHONY POWER BEAM
(SEE PLAN FOR SIZE)
FOUNDATION:
1. WALLS SHOWN FOR CLARITY ONLY.
R401.1 GEOTECHNICAL EVALUATIONS - In lieu of a complete geotechincal evaluation, the load-bearing values in table R401.4.1 shall be assumed.
R401.4.1
CLASS OF MATERIAL LOAD BEARING PRESSURE
(POUNDS PER SQ. FT.)
CLAY, SANDY CLAY, SILTY CLAY,
1500CAYEY SILT, SILT AND SANDY SILT
(CL, ML, MH, & CH)
OUTER BEAM
SHALL BE NOTCHED
& BOLTED TO POST
(2) 5 8"Ø BOLTS PER
BEAM (TYP.)
PORCH POST
PER PLAN
INNER BEAM TO POST W/
CONCEALED HANGER
(SEE SCHEDULE)
N.T.S.
SECTION Z-Z
Z
Z
INNER BEAM TO POST
W/ CONCEALED HANGER
(SEE SCHEDULE)
OUTER BEAM
SHALL BE NOTCHED
& BOLTED TO POST
(2) 5 8"Ø BOLTS PER
BEAM (TYP.)
PORCH POST
PER PLAN
N.T.S.
CORNER PORCH POST DETAIL
2"
2"
FOUNDATION & CEILING JOIST PLANS
ALL OPTIONS (STANDARD)
Revisions:
PROJECT LOCATION OR ADDRESS:
CLIENT:
# DATE DESCRIPTION OF CHANGE
CHECKED BY:
SCALE:
DRAWN BY:
PROJECT #:
DATE:
CCH
NOTE: SIGNATURES VALID FOR ONE YEAR ONLY AFTER DATE OF SIGNATURES
ALL RIGHTS RESERVED. NO PART OF THIS DOCUMENT MAY BE REPRODUCED OR
UTILIZED IN ANY FORM WITHOUT PRIOR WRITTEN AUTHORIZATION OF “COBALT”.
CLIENT
ADDRESS
XXXXXXXX,TX 77XXX
XX-XXXX-XX
0 ISSUED FOR CONSTRUCTION
XX-XXXX-HRAP-ASH-SOG-XX/XX/2023
XX/XX/2023
THIS DRAWING IS A CONCEPTUAL PLAN AND IS NOT
INTENDED TO BE USED AS A SITE SPECIFIC PLAN NOR
SHALL IT BE USED FOR PERMITTING PURPOSES. SITE
SPECIFICS SHALL BE PREPARED ON A CASE-BY-CASE
BASIS AND ANY USE BEYOND THE AFOREMENTIONED
INTENT IS PROHIBITED.
® phone: 409-354-5925 email: info@cobalt-engineering.com
ENGINEERING AND INSPECTIONS, LLC
4"=1'-0"
AW
HANGER SCHEDULE
MARK MEMBER SIZE MODEL NUMBER
1 2X6 LUS26 OR LUC26Z CONCEALED
(2) 2X6 LUS26-2 OR HUC26-2 CONCEALED
5 2X10 LUS210 OR LUC210Z CONCEALED
(2) 2X10 HUS210-2 OR HUC210-2 CONCEALED
4 (2) 2X8 LUS28-2 OR HUC28-2 CONCEALED
SOME MODELS MAY NOT BE USED
(SEE FRAMING PLAN FOR LOCATION)
2X8 LUS28 OR LUC28Z CONCEALED
2X12 HUS210 OR LUC210Z CONCEALED7
FOUNDATION PLAN (STANDARD)
ALL OPTIONS
CEILING JOIST PLAN (STANDARD)
S-1.00
RAKE EDGE
RAKE EDGE
R
ID
G E
5:125:12
CEILING FORMED BY
PRE-ENGINEERED
ROOF TRUSS
(DESIGNED BY OTHER)
5:12 5:12
R
ID
G E
1 1
1 1
SW3
SW
1SW
SW4
LEGEND
FRAMING:
1. ALL STUDS, FLOOR JOISTS, RAFTERS, TRUSS,
ETC. SHALL VERTICALLY ALIGN AND BEAR
DIRECTLY ON EACH OTHER.
ROOF FRAMING:
1. ROOF DECKING: 15
32" APA RATED PLYWOOD OR
7/16" APA RATED OSB, 0.113 x 2-3/8" RING SHANK
NAILS, 4" AROUND PERIMETER OF DIAPHRAGM. 4"
EDGE & 4" FIELD NAIL PATTERN.
2. RIDGES TO BE 2x10 (UNO)
3. ALL HIPS TO BE 2x8 (UNO)
4. ALL RAFTERS TO BE 2x6 16"O.C. (UNO)
5. RAFTER TAILS SHALL BE A CONTINUOUS
MEMBER EXTENDING FROM RAFTER (NO SPLICE)
6. ALL SHINGLES SHALL BE 30 YEAR W/ ASTM D7158
CLASS H WITH 6 NAIL PER SHINGLE.
BRACE POINT
BW - BRACE TO WALL
BS - BRACE TO STRONGBACK
BB - BRACE TO BEAM
SHEAR WALLS:
STHD14 W/ (30) 16D SINKER NAILS IN STUD
PACK PER MANUFACTURERS
INSTRUCTIONS
OR
HDU5-SDS2.5 USE (14) 14"X21
2"SDS SCREWS
PER MANUFACTURERS INSTRUCTIONS
ALL SHEARWALLS SHALL EXTEND TO ROOF
DIAPHRAGM OR NEXT FLOOR DIAPHRAGM.
HOLD-DOWNS:
15/32" APA RATED PLYWOOD OR 7/16"
APA RATED OSB SHEATHING 6"
PERIMETER AND W/6" EDGE / 6" FIELD
NAIL PATTERN USING 0.113 x 2-3/8"
RING SHANK NAILS
SW1
15/32" APA RATED PLYWOOD OR 7/16"
APA RATED OSB SHEATHING 3"
PERIMETER AND W/3" EDGE / 6" FIELD
NAIL PATTERN USING 0.113 x 2-3/8"
RING SHANK NAILS
SW3
15/32" APA RATED PLYWOOD OR 7/16"
APA RATED OSB SHEATHING 4"
PERIMETER AND W/4" EDGE / 6" FIELD
NAIL PATTERN USING 0.113 x 2-3/8"
RING SHANK NAILS
SW4
HDU8-SDS2.5 USE (20) 14"X21
2"SDS SCREWS
PER MANUFACTURERS INSTRUCTIONS
NOTES
4"=1'-0"
AW
RAFTER & SHEARWALL PLAN
##################### (STANDARD)
Revisions:
PROJECT LOCATION OR ADDRESS:
CLIENT:
# DATE DESCRIPTION OF CHANGE
CHECKED BY:
SCALE:
DRAWN BY:
PROJECT #:
DATE:
CCH
NOTE: SIGNATURES VALID FOR ONE YEAR ONLY AFTER DATE OF SIGNATURES
ALL RIGHTS RESERVED. NO PART OF THIS DOCUMENT MAY BE REPRODUCED OR
UTILIZED IN ANY FORM WITHOUT PRIOR WRITTEN AUTHORIZATION OF “COBALT”.
CLIENT
ADDRESS
XXXXXXXX,TX 77XXX
XX-XXXX-XX
0 ISSUED FOR CONSTRUCTION
XX-XXXX-HRAP-ASH-SOG-XX/XX/2023
XX/XX/2023
THIS DRAWING IS A CONCEPTUAL PLAN AND IS NOT
INTENDED TO BE USED AS A SITE SPECIFIC PLAN NOR
SHALL IT BE USED FOR PERMITTING PURPOSES. SITE
SPECIFICS SHALL BE PREPARED ON A CASE-BY-CASE
BASIS AND ANY USE BEYOND THE AFOREMENTIONED
INTENT IS PROHIBITED.
® phone: 409-354-5925 email: info@cobalt-engineering.com
ENGINEERING AND INSPECTIONS, LLC
RAFTER PLAN (STANDARD)
SHEARWALL & HOLD-DOWN PLAN (STANDARD)
S-2.00
01 ROOF PLAN (STANDARD) 02 FLOOR PLAN (STANDARD)
OPTION 1 OPTION 1
SLOPE
5:12
SLOPE
5:12
EXHAUST
VENT WITH
DAMPER AND
CAP
SQUARE FOOTAGE CALCULATIONS
LOCATION SQUARE FOOTAGE REMARKS
FLOOR PLAN 899 S.F.
COVERED
PORCH 47 S.F.
REAR PATIO 47 S.F.
*SEE FLOOR PLAN FOR KITCHEN
AND LAUNDRY ROOM VENTING
WINDOW SCHEDULE
MARK QTY. DESCRIPTIONS REMARKS
A 4 3'-0" X 5'-0" SINGLE HUNG
B 1 3'-0" X 3'-0" SINGLE HUNG
DOOR SCHEDULE
MARK QTY DESCRIPTIONS REMARKS
01 1 3'-0" X 6'-8" EXTERIOR WITH PEEPHOLE
02 1 3'-0" X 6'-8" EXTERIOR DOOR
03 6 3'-0" X 6'-8" INTERIOR
04 2 (2) 2'-0" X 6'-8" DOUBLE DOORS
05 1 2'-6" X 6'-8" INTERIOR
06 1 2'-8" X 6'-8' VENTED
07 1 22" X 30" MIN. ATTIC ACCESS 350 POUND LADDER RATING
NOTE: ALL CABINET
DIMENSIONS ARE TO
BE FIELD VERIFIED
AND ARE THE
RESPONSIBILITY OF
THE CONTRACTOR
R
EF
LAUNDRY
56 S.F.
9' CLG.
W
D
COVERED
PORCH
47 S.F.
WH
BEDROOM 1
104 S.F.
9' CLG.
BATHROOM
64 S.F.
9' CLG.
SI
N
K D
W
PA
N
TR
Y
LIVING/DINING
ROOM
120 S.F.
9' CLG.
KITCHEN
113 S.F.
9' CLG.
CLO. 12 S.F.
R
AN
G E
TO
VE
N T
TH
R
O U
G H
R O
O F
NOTE: ALL WINDOWS AND DOORS TO HAVE A STC RATING OF 40 OR HIGHER
A
A
A
A
B
BEDROOM 2
112 S.F.
9' CLG.
BEDROOM 3
112 S.F.
9' CLG.
6'-3"5'-11"2'-0"4'-11 1/2"3'-11 1/2" 12'-2"10'-11"
23'-1"
5' -0
5'
-4
'-4
2'
-0
2' -0
'-2
3' -0
6'
-6
2' -2
'-6
6'-3"5'-11"5'-0"5'-11" 12'-2"10'-11"
'-8
'-9
/2
8'
-6
/2
'-4
4'
-0
7' -0
'-5
3'-2"
4' -4
3'
-0
A/C
CLO. 12 S.F.
CLO. 7 S.F.
03 03
REAR
PORCH
47 S.F.
4'-0"
4' -2
6' -2
4'-4"
7'-8"
5'-3" 2'-5"
4'-4"3'-4"
SLOPE
5:12
SEE NOTE 3
4'-0"2'-6" Revisions:
PROJECT LOCATION OR ADDRESS:
CLIENT:
# DATE DESCRIPTION OF CHANGE
CHECKED BY:
SCALE:
DRAWN BY:
PROJECT #:
DATE:
CCH
NOTE: SIGNATURES VALID FOR ONE YEAR ONLY AFTER DATE OF SIGNATURES
ALL RIGHTS RESERVED. NO PART OF THIS DOCUMENT MAY BE REPRODUCED OR
UTILIZED IN ANY FORM WITHOUT PRIOR WRITTEN AUTHORIZATION OF “COBALT”.
CLIENT
ADDRESS
XXXXXXXX,TX 77XXX
XX-XXXX-XX
0 ISSUED FOR CONSTRUCTION
XX-XXXX-HRAP-ASH-SOG-XX/XX/2023
XX/XX/2023
THIS DRAWING IS A CONCEPTUAL PLAN AND IS NOT
INTENDED TO BE USED AS A SITE SPECIFIC PLAN NOR
SHALL IT BE USED FOR PERMITTING PURPOSES. SITE
SPECIFICS SHALL BE PREPARED ON A CASE-BY-CASE
BASIS AND ANY USE BEYOND THE AFOREMENTIONED
INTENT IS PROHIBITED.
® phone: 409-354-5925 email: info@cobalt-engineering.com
ENGINEERING AND INSPECTIONS, LLC
1/4" = 1'-0"
A-1.00
HUBBLE
FLOOR PLAN - ROOF PLAN
OPTION 1 (STANDARD)
DAS
NOTES
1. WHEN REQUIRED SEE SHEET C-1.00 FOR LAYOUT
AND LOCATION OF RAMP AND STAIRS
2. WHEN REQUIRED SEE SHEET SD-4.00 FOR RAMP
AND STAIR DETAILS
3. ROOF OVERHANG SHALL BE A MINIMUM OF 18
INCHES (INCLUDING GUTTERS) BEYOND THE
OUTTER MOST PORTION IF ANY EXTERIOR
VENEER. CONTRACTOR TO ADJUST RAFTER
TAILS AS REQUIRED.
4. WINDOWS USED FOR EGRESS SHALL HAVE A NET
CLEAR OPENING OF NOT LESS THAN 5.7 S.F.
WITH A MINIMUM HEIGHT OF 24" AND A MINIMUM
WIDTH OF 20" PER THE INTERNATIONAL
RESIDENTIAL CODE.
5. PLAIN HALF-ROUND 6" WIDE AND 4" DIAMETER
DOWNSPOUT, MINIMUM 22-GAUGE GALVANIZED
STEEL, PREFINISHED. OR STANDARD K-STYLE 6"
WIDE AND 3"X4" DOWNSPOUT, MINIMUM
22-GAUGE GALVANIZED STEEL, PREFINISHED.
6. ALL DOWNSPOUTS TO HAVE SPLASH BLOCK.
7. SMART VENT (1540-510) FLOOD VENTS ARE
REQUIRED WHEN ENCLOSED SPACE IS BELOW
B.F.E. IN AN "A" FLOOD ZONE.
8. FEMA APPROVED BREAKAWAY WALLS OR
LOUVERS ARE REQUIRED WHEN ENCLOSED
SPACE IS BELOW B.F.E. IN A "V" FLOOD ZONE.
9. ALL MATERIALS BELOW BFE AND/OR DFE SHALL
BE FLOOD RESISTANT MATERIAL INCLUDING, BUT
NOT LIMITED TO TREATED FRAMING MATERIAL.
SEE FEMA TECHNICAL BULLETIN 2, FLOOD
DAMAGE RESISTANT MATERIALS REQUIREMENTS
(2008).
10. RAIN DIVERTER STRIP IS REQUIRED OVER A/C
UNIT AND ENTRANCES.
THE ATTIC ACCESS IS REQUIRED TO BE A MINIMUM
OF 22”X30”, ASSUMING THAT NO EQUIPMENT WILL BE
INSTALLED IN THE ATTIC SPACE. IT IS THE
RESPONSIBILITY OF THE GENERAL CONTRACTOR TO
CONFIRM SITE SPECIFIC REQUIREMENTS.”
11. SEE STRUCTURAL FOUNDATION PLAN FOR
FLATWORK DIMENSIONS.
01 FRONT ELEVATION (STANDARD) 02 RIGHT ELEVATION (STANDARD)
03 REAR ELEVATION (STANDARD) 04 LEFT ELEVATION (STANDARD)
OPTION 1 OPTION 1
OPTION 1OPTION 1
ATTIC VENTILATION CALCULATION
AREA SQUARE FOOTAGE
TOTAL AREA 1,130 S.F.
TOTAL REQUIRED VENTED AREA (1/150) 7.53 S.F.
REQUIRED RIDGE (HIP) VENTILATION 3.77
REQUIRED SOFFIT VENTILATION 3.77
2' -0
12 5
F.F.E. = +6" A.G. MIN.
NATURAL GRADE
9'
-0
PLATE HEIGHT
APPROX. HEIGHT
5' -2
F.F.E. = +6" A.G. MIN.
NATURAL GRADE
9' -0
PLATE HEIGHT
APPROX. HEIGHT
5' -2
EXHAUST VENT WITH
DAMPER AND CAP
30-YEAR
ARCHITECTURAL
SHINGLES
30-YEAR
ARCHITECTURAL
SHINGLES
12 5
A
FIBER
CEMENT
SIDING
POST
SEE NOTE 3
A
F.F.E. = +6" A.G. MIN.
NATURAL GRADE
9' -0
PLATE HEIGHT
APPROX. HEIGHT
5' -3
SEE NOTE 3
FIBER
CEMENT
SIDING
TRIM
A
A
F.F.E. = +6" A.G. MIN.
NATURAL GRADE
9' -0
PLATE HEIGHT
APPROX. HEIGHT
5' -2
" SEE NOTE 3
FIBER
CEMENT
SIDING
TRIM
B
TRIM
FIBER
CEMENT
SIDING
SEE NOTE 3
Revisions:
PROJECT LOCATION OR ADDRESS:
CLIENT:
# DATE DESCRIPTION OF CHANGE
CHECKED BY:
SCALE:
DRAWN BY:
PROJECT #:
DATE:
CCH
NOTE: SIGNATURES VALID FOR ONE YEAR ONLY AFTER DATE OF SIGNATURES
ALL RIGHTS RESERVED. NO PART OF THIS DOCUMENT MAY BE REPRODUCED OR
UTILIZED IN ANY FORM WITHOUT PRIOR WRITTEN AUTHORIZATION OF “COBALT”.
CLIENT
ADDRESS
XXXXXXXX,TX 77XXX
XX-XXXX-XX
0 ISSUED FOR CONSTRUCTION
XX-XXXX-HRAP-ASH-SOG-XX/XX/2023
XX/XX/2023
THIS DRAWING IS A CONCEPTUAL PLAN AND IS NOT
INTENDED TO BE USED AS A SITE SPECIFIC PLAN NOR
SHALL IT BE USED FOR PERMITTING PURPOSES. SITE
SPECIFICS SHALL BE PREPARED ON A CASE-BY-CASE
BASIS AND ANY USE BEYOND THE AFOREMENTIONED
INTENT IS PROHIBITED.
® phone: 409-354-5925 email: info@cobalt-engineering.com
ENGINEERING AND INSPECTIONS, LLC
1/4" = 1'-0"
A-2.00
HUBBLE
EXTERIOR ELEVATIONS
OPTION 1 (STANDARD)
DAS
NOTES
1. WHEN REQUIRED SEE SHEET C-1.00 FOR LAYOUT
AND LOCATION OF RAMP AND STAIRS
2. WHEN REQUIRED SEE SHEET SD-4.00 FOR RAMP
AND STAIR DETAILS
3. ROOF OVERHANG SHALL BE A MINIMUM OF 18
INCHES (INCLUDING GUTTERS) BEYOND THE
OUTTER MOST PORTION IF ANY EXTERIOR
VENEER. CONTRACTOR TO ADJUST RAFTER
TAILS AS REQUIRED.
4. WINDOWS USED FOR EGRESS SHALL HAVE A NET
CLEAR OPENING OF NOT LESS THAN 5.7 S.F.
WITH A MINIMUM HEIGHT OF 24" AND A MINIMUM
WIDTH OF 20" PER THE INTERNATIONAL
RESIDENTIAL CODE.
5. PLAIN HALF-ROUND 6" WIDE AND 4" DIAMETER
DOWNSPOUT, MINIMUM 22-GAUGE GALVANIZED
STEEL, PREFINISHED. OR STANDARD K-STYLE 6"
WIDE AND 3"X4" DOWNSPOUT, MINIMUM
22-GAUGE GALVANIZED STEEL, PREFINISHED.
6. ALL DOWNSPOUTS TO HAVE SPLASH BLOCK.
7. SMART VENT (1540-510) FLOOD VENTS ARE
REQUIRED WHEN ENCLOSED SPACE IS BELOW
B.F.E. IN AN "A" FLOOD ZONE.
8. FEMA APPROVED BREAKAWAY WALLS OR
LOUVERS ARE REQUIRED WHEN ENCLOSED
SPACE IS BELOW B.F.E. IN A "V" FLOOD ZONE.
9. ALL MATERIALS BELOW BFE AND/OR DFE SHALL
BE FLOOD RESISTANT MATERIAL INCLUDING, BUT
NOT LIMITED TO TREATED FRAMING MATERIAL.
SEE FEMA TECHNICAL BULLETIN 2, FLOOD
DAMAGE RESISTANT MATERIALS REQUIREMENTS
(2008).
10. RAIN DIVERTER STRIP IS REQUIRED OVER A/C
UNIT AND ENTRANCES.
THE ATTIC ACCESS IS REQUIRED TO BE A MINIMUM
OF 22”X30”, ASSUMING THAT NO EQUIPMENT WILL BE
INSTALLED IN THE ATTIC SPACE. IT IS THE
RESPONSIBILITY OF THE GENERAL CONTRACTOR TO
CONFIRM SITE SPECIFIC REQUIREMENTS.”
11. SEE STRUCTURAL FOUNDATION PLAN FOR
FLATWORK DIMENSIONS.
03 ELECTRICAL PLAN (STANDARD)
03 WINDOW FL21 CUSTOMING DETAIL
ALL OPTIONS
NOTE: WHEN GAS DRYER IS USED, A DEDICATED 240-VOLD BRANCH
CIRCUIT WITHIN 3 FEET OF THE DRYER IS TO BE USED. THIS CIRCUIT
SHALL HAVE A MINIMUM 30 AMP RATING. WHEN GAS RANGE IS USED, A
DEDICATED 240-VOLD BRANCH CIRCUIT IS TO BE USED. THIS CIRCUIT
SHALL HAVE A MINIMUM 50 AMP RATING. THE MAIN ELECTRICAL SERVICE
SHALL HAVE A RESERVED SPACE TO ALLOW FOR THE INSTALLATION OF A
DOUBLE POLE CIRCUIT BREAKER. THE RESERVED SPACE SHALL BE
PERMANENTLY MARKED "FOR FUTURE 240V USE".
GFI 18" AFF
(DISHW21 CUSTOMER)
GFI 18" AFF
(FOOD DISPOSAL)
W/P GFI OD
EF
A/C
LI
G
H T
D
W
220V
GFI
GFI
OD
GFI 42"
AFF
GFI 48" AFF
BREAKER
BOX 48" AFF
SD
SD
SD
CD
CD
GFI 42" AFF
GFI
GFI 72" AFF
Revisions:
PROJECT LOCATION OR ADDRESS:
CLIENT:
# DATE DESCRIPTION OF CHANGE
CHECKED BY:
SCALE:
DRAWN BY:
PROJECT #:
DATE:
CCH
NOTE: SIGNATURES VALID FOR ONE YEAR ONLY AFTER DATE OF SIGNATURES
ALL RIGHTS RESERVED. NO PART OF THIS DOCUMENT MAY BE REPRODUCED OR
UTILIZED IN ANY FORM WITHOUT PRIOR WRITTEN AUTHORIZATION OF “COBALT”.
CLIENT
ADDRESS
XXXXXXXX,TX 77XXX
XX-XXXX-XX
0 ISSUED FOR CONSTRUCTION
XX-XXXX-HRAP-ASH-SOG-XX/XX/2023
XX/XX/2023
THIS DRAWING IS A CONCEPTUAL PLAN AND IS NOT
INTENDED TO BE USED AS A SITE SPECIFIC PLAN NOR
SHALL IT BE USED FOR PERMITTING PURPOSES. SITE
SPECIFICS SHALL BE PREPARED ON A CASE-BY-CASE
BASIS AND ANY USE BEYOND THE AFOREMENTIONED
INTENT IS PROHIBITED.
® phone: 409-354-5925 email: info@cobalt-engineering.com
ENGINEERING AND INSPECTIONS, LLC
HUBBLE
ELECTRICAL PLAN AND SECTIONS
ALL OPTIONS (STANDARD)
N.T.S.
A-3.00
DAS
LEGEND
CEILING FAN W/ LIGHT KIT
SURFACE MOUNTED LIGHT FIXTURE
55 CFM EXHAUST FAN / LIGHT
OUTDOOR SCONCE
SWITCH
STANDARD AFCI RECEPTACLE
220V RECEPTACLE
RECEPTACLE WITH GROUND FAULT
INTERCEPT
WATERPROOF WITH GROUND FAULT
INTERCEPT
OVERHEAD RECEPTACLE
RECESSED CAN LIGHT
SMOKE DETECTOR
COMBO SMOKE / CARBON MONOXIDE
DETECTOR
CHANDELIER
TV / PHONE JACK
HOT / COLD WATER SUPPLY
HOSE BIB
EXHAUST VENT
EF
OD
HB
WP
GFCI
OH
GFCI
SD
CD
NOTES
1. MAIN PANEL TO HAVE A MAIN
BREAKER/DISCONNECT AND SURGE
PROTECTOR
2. 110V RECEPTACLE TO BE WITHIN 25' OF
EXTERIOR AIR COMPRESSOR
PROVIDE ONE 110V, WEATHER PROTECTED GFCI OUTLET
WITHIN 25' OF OUTSIDE HEATING/COOLING EQUIPMENT.
PLUMBING LEGEND
3" MAIN SANITARY LINE, PROVIDE CLEAN OUT AT
EXTERIOR OF HOUSE
2" VENT PIPE
3" SANITARY TO TOILET
2" SANITARY AT SINK AND SHOWER
3" SANITARY AT W21 CUSTOMER
4" SANITARY FROM CITY TO HOUSE
W21 CUSTOMER & SINK RISER DETAILS
02 PLUMBING PLAN (STANDARD)
ALL OPTIONS
01 PLUMBING PLAN (STANDARD)
ALL OPTIONS
HB
3/4" Ø UNIT SUPPLY,
FIELD VERIFY LOCATION
& DIAMETER
NOT TO SCALE
HB
3/4"Ø CW
1/2"Ø HW DW
1/2"Ø CW DW
1/2"Ø HW DW
1/2"Ø CW DW
1/2"Ø HW DW
1/2"Ø CW DW
1/2"Ø HW DW
1/2"Ø CW DW
1/2"Ø HW DW
1/2"Ø CW DW
1/2"Ø CW DW
3/4"Ø CW
3/4"Ø CW
3/4"Ø CW
3/4"Ø CW
3/4"Ø CW
3/4"Ø CW
3/4"Ø CW
HWHW
H W
H W
H W
H W
H W
H W
H W
H W
H W
H W
HWHWHW
HWHWHW
HW HW HW
HWHWHWHWHW
2-WAY TEE STYLE
CLEAN OUT
WYE CLEAN OUT
3' FROM
PROPERTY LINE
SEWER TO BE 4" WITH
A TWO WAY CLEANOUT
AT THE PROPERTY LINE
AND AT THE BUILDING
DRAIN TO BUILDING
SEWER CONNECTION
Revisions:
PROJECT LOCATION OR ADDRESS:
CLIENT:
# DATE DESCRIPTION OF CHANGE
CHECKED BY:
SCALE:
DRAWN BY:
PROJECT #:
DATE:
CCH
NOTE: SIGNATURES VALID FOR ONE YEAR ONLY AFTER DATE OF SIGNATURES
ALL RIGHTS RESERVED. NO PART OF THIS DOCUMENT MAY BE REPRODUCED OR
UTILIZED IN ANY FORM WITHOUT PRIOR WRITTEN AUTHORIZATION OF “COBALT”.
CLIENT
ADDRESS
XXXXXXXX,TX 77XXX
XX-XXXX-XX
0 ISSUED FOR CONSTRUCTION
XX-XXXX-HRAP-ASH-SOG-XX/XX/2023
XX/XX/2023
THIS DRAWING IS A CONCEPTUAL PLAN AND IS NOT
INTENDED TO BE USED AS A SITE SPECIFIC PLAN NOR
SHALL IT BE USED FOR PERMITTING PURPOSES. SITE
SPECIFICS SHALL BE PREPARED ON A CASE-BY-CASE
BASIS AND ANY USE BEYOND THE AFOREMENTIONED
INTENT IS PROHIBITED.
® phone: 409-354-5925 email: info@cobalt-engineering.com
ENGINEERING AND INSPECTIONS, LLC
A-4.00
HUBBLE
PLUMBING PLAN
(STANDARD)
DAS
LEGEND
NOTES
1. THIS DRAWING IS INTENDED FOR
USE AS A RECOMMENDED
LAYOUT. THE GENERAL
CONTRACTOR IS RESPONSIBLE
FOR MEETING WITH APPLICABLE
CODE.
2. EXHAUST FANS SHALL VENT
DIRECTLY TO THE OUTSIDE AND
BE LOCATED IN ACCORDANCE
WITH SECTIONS R303.5.1 AND
R303.5.2 OF THE INTERNATIONAL
RESIDENTIAL CODE.
3. ALL HOSE CONNECTIONS SHALL
BE EQUIPPED WITH
NON-REMOVABLE BACK FLOW
PREVENTERS PER IRC 603.3.3.
4. CLEANOUT REQUIRED ABOVE
FLOOR LEVEL OF LOWEST FLOOR
OF BUILDING FOR KITCHEN SINK.
AND IS TO BE ON THE OUTSIDE
WALL.
5. MINIMUM 30" X 22" RETURN AIR
GRILLE.
6. MECHANICAL DRAIN LINES
CANNOT CONNECT TO PLUMBING
SYSTEM.
HOSE BIB
EXHAUST VENT
HB
01 HVAC PLAN (STANDARD)
10"X6"
1WAY
6"Ø
10"X6"
1WAY
6"Ø
"X
AIR
HANDLER
"X
10"X6"
1WAY
6"Ø
10"X6"
1WAY
6"Ø
10"X6"
1WAY
6"Ø
10"X6"
1WAY
6"Ø
10"X6"
1WAY
6"Ø
Revisions:
PROJECT LOCATION OR ADDRESS:
CLIENT:
# DATE DESCRIPTION OF CHANGE
CHECKED BY:
SCALE:
DRAWN BY:
PROJECT #:
DATE:
CCH
NOTE: SIGNATURES VALID FOR ONE YEAR ONLY AFTER DATE OF SIGNATURES
ALL RIGHTS RESERVED. NO PART OF THIS DOCUMENT MAY BE REPRODUCED OR
UTILIZED IN ANY FORM WITHOUT PRIOR WRITTEN AUTHORIZATION OF “COBALT”.
CLIENT
ADDRESS
XXXXXXXX,TX 77XXX
XX-XXXX-XX
0 ISSUED FOR CONSTRUCTION
XX-XXXX-HRAP-ASH-SOG-XX/XX/2023
XX/XX/2023
THIS DRAWING IS A CONCEPTUAL PLAN AND IS NOT
INTENDED TO BE USED AS A SITE SPECIFIC PLAN NOR
SHALL IT BE USED FOR PERMITTING PURPOSES. SITE
SPECIFICS SHALL BE PREPARED ON A CASE-BY-CASE
BASIS AND ANY USE BEYOND THE AFOREMENTIONED
INTENT IS PROHIBITED.
® phone: 409-354-5925 email: info@cobalt-engineering.com
ENGINEERING AND INSPECTIONS, LLC
A-5.00
HUBBLE
HVAC PLAN
(STANDARD)
DAS
EXHAUST FAN
SUPPLY AIR REGISTER
FLEX DUCT (R-8 MIN.)
RECTANGULAR DUCT (R-8 MIN.)
LEGEND
NOTES
1. THIS DRAWING IS INTENDED FOR
USE AS A RECOMMENDED
LAYOUT. THE GENERAL
CONTRACTOR IS RESPONSIBLE
FOR MEETING WITH APPLICABLE
CODE.
2. EXHAUST FANS SHALL VENT
DIRECTLY TO THE OUTSIDE AND
BE LOCATED IN ACCORDANCE
WITH SECTIONS R303.5.1 AND
R303.5.2 OF THE INTERNATIONAL
RESIDENTIAL CODE.
3. ALL HOSE CONNECTIONS SHALL
BE EQUIPPED WITH
NON-REMOVABLE BACK FLOW
PREVENTERS PER IRC 603.3.3.
4. CLEANOUT REQUIRED ABOVE
FLOOR LEVEL OF LOWEST FLOOR
OF BUILDING FOR KITCHEN SINK.
AND IS TO BE ON THE OUTSIDE
WALL.
5. MINIMUM 30" X 22" RETURN AIR
GRILLE.
6. MECHANICAL DRAIN LINES
CANNOT CONNECT TO PLUMBING
SYSTEM.
A F-1.00
C F-1.00
4" THK. 3000 P.S.I. CONC. SLAB
W/ 6X6 #10 W.W.M. OVER
TREATED, COMPACTED FILL W/
10 MIL. VAPOR BARRIER @
INTERIOR LOCATIONS (U.N.O.)
12'-2"11'-2"
6X6 POST TO FND
WITH ABU66Z
POST BASE
F-1.00
SL
O
PE
HUB DRAIN
HUB DRAIN
12'-2"11'-2"
'-5
8'
-8
'-1
0" 9'
-8
7' -1
2' -3
4'
-3
'-3
'-1 0"
9' -3
4'
-3
5' -7
0'-3"
0' -3
0" D
R O
P
VARIES
DROP
A F-1.00
A F-
1.
A F-
1.
A F-
1.
A F-
1.
C F-
1.
0" D
R O
P
SL
O
PE
2'
-8
10'-7 1/4" 8'-7 3/4"
6' -7
/2
1'-11 1/2"
'-3
/4
'-2
/4
6'-2"
3'-0"
'-1
3/
4"
0'-3 1/2"
'-9
/2
0'-3"
0'-3"
(2)2X10 DROP
BEAM
THIS DWG.
CORNER PORCH
POST DETAIL (TYP.)
12'-2"10'-11"
9' -1
0" 2'
-0
2' -0
'-4
3' -0
6'
-3
2' -5
'-1 0"
10'-11" 12'-2"
7' -0
5'
-4
'-0
4'
-0
(2 )2
X1
D R
O P
BE
AM
9' -1
0"
23'-1"
2' -6
'-8
02/SD-1.00
BEAM POCKET
(TYP. 2 PLCS.)
LEGEND
NOTES
CEILING FRAMING:
1. ALL CEILING JOISTS SHALL BE 2X6 16" O.C.
(U.N.O.)
2. ATTIC ACCESS SHALL BE NO LESS THAN
350LB CAPACITY FOLDING STAIR SYSTEM.
X
XX
---- DETAIL
---- PAGE #
FRAMING:
1. ALL STUDS, FLOOR JOISTS, RAFTERS, TRUSS,
ETC. SHALL VERTICALLY ALIGN AND BEAR
DIRECTLY ON EACH OTHER.
FULL HEIGHT BLOCKING
TYPICAL STRONG BACK SEE
DETL. #3 ON DWG. SD-2.00
PONY WALL EXTENDED
TO ROOF DIAPHRAGM
CONCRETE HOLD-DOWNS:
1. SEE DRAWING S-2.00 FOR TYPE OF
HOLD-DOWN REQUIRED.
2. SEE DRAWING F-1.00 FOR HOLD-DOWN
INSTALLATION DETAIL. (REFER TO
MANUFACTURERS INSTALLATION
INSTRUCTIONS FOR ADDITIONAL REQ'S.)
HEADER FRAMING:
1. REFER TO DETAIL 1 ON SD-1.00 FOR ALL
HEADER REQUIREMENTS. (U.N.O.)
2. POCKET DOOR HEADERS SHALL SPAN THE
OPENING & THE DOOR CAVITY (TYPICAL)
STUD PACK FRAMING:
1. (4) 2X STUD PACK UNDER EACH END OF 2X
SOLID SAWN BEAM.
2. (6) 2X STUD PACK UNDER EACH END OF
GLULAM BEAM. (SEE PLAN FOR BEAM SIZE)
3000Fb ANTHONY POWER BEAM
(SEE PLAN FOR SIZE)
FOUNDATION:
1. WALLS SHOWN FOR CLARITY ONLY.
R401.1 GEOTECHNICAL EVALUATIONS - In lieu of a complete geotechincal evaluation, the load-bearing values in table R401.4.1 shall be assumed.
R401.4.1
CLASS OF MATERIAL LOAD BEARING PRESSURE
(POUNDS PER SQ. FT.)
CLAY, SANDY CLAY, SILTY CLAY,
1500CAYEY SILT, SILT AND SANDY SILT
(CL, ML, MH, & CH)
OUTER BEAM
SHALL BE NOTCHED
& BOLTED TO POST
(2) 5 8"Ø BOLTS PER
BEAM (TYP.)
PORCH POST
PER PLAN
INNER BEAM TO POST W/
CONCEALED HANGER
(SEE SCHEDULE)
N.T.S.
SECTION Z-Z
Z
Z
INNER BEAM TO POST
W/ CONCEALED HANGER
(SEE SCHEDULE)
OUTER BEAM
SHALL BE NOTCHED
& BOLTED TO POST
(2) 5 8"Ø BOLTS PER
BEAM (TYP.)
PORCH POST
PER PLAN
N.T.S.
CORNER PORCH POST DETAIL
2"
2"
HUBBLE
FOUNDATION & CEILING JOIST PLANS
ALL OPTIONS (STANDARD)
Revisions:
PROJECT LOCATION OR ADDRESS:
CLIENT:
# DATE DESCRIPTION OF CHANGE
CHECKED BY:
SCALE:
DRAWN BY:
PROJECT #:
DATE:
CCH
NOTE: SIGNATURES VALID FOR ONE YEAR ONLY AFTER DATE OF SIGNATURES
ALL RIGHTS RESERVED. NO PART OF THIS DOCUMENT MAY BE REPRODUCED OR
UTILIZED IN ANY FORM WITHOUT PRIOR WRITTEN AUTHORIZATION OF “COBALT”.
CLIENT
ADDRESS
XXXXXXXX,TX 77XXX
XX-XXXX-XX
0 ISSUED FOR CONSTRUCTION
XX-XXXX-HRAP-ASH-SOG-XX/XX/2023
XX/XX/2023
THIS DRAWING IS A CONCEPTUAL PLAN AND IS NOT
INTENDED TO BE USED AS A SITE SPECIFIC PLAN NOR
SHALL IT BE USED FOR PERMITTING PURPOSES. SITE
SPECIFICS SHALL BE PREPARED ON A CASE-BY-CASE
BASIS AND ANY USE BEYOND THE AFOREMENTIONED
INTENT IS PROHIBITED.
® phone: 409-354-5925 email: info@cobalt-engineering.com
ENGINEERING AND INSPECTIONS, LLC
4"=1'-0"
AW
HANGER SCHEDULE
MARK MEMBER SIZE MODEL NUMBER
1 2X6 LUS26 OR LUC26Z CONCEALED
(2) 2X6 LUS26-2 OR HUC26-2 CONCEALED
5 2X10 LUS210 OR LUC210Z CONCEALED
(2) 2X10 HUS210-2 OR HUC210-2 CONCEALED
4 (2) 2X8 LUS28-2 OR HUC28-2 CONCEALED
SOME MODELS MAY NOT BE USED
(SEE FRAMING PLAN FOR LOCATION)
2X8 LUS28 OR LUC28Z CONCEALED
2X12 HUS210 OR LUC210Z CONCEALED7
FOUNDATION PLAN (STANDARD)
ALL OPTIONS
CEILING JOIST PLAN (STANDARD)
S-1.00
R
ID
G E
5:12 5:12
CEILING FORMED BY
PRE-ENGINEERED
ROOF TRUSS
(DESIGNED BY OTHER)
RAKE EDGE
RAKE EDGE
01/SD-2.00
DOUBLE RAFTER
& OUT-LOOKERS
AT GABLE END
WALL (TYP.)
SW3
1 1
SW4
SW4
SW
SW
SW
SW3
SW
LEGEND
FRAMING:
1. ALL STUDS, FLOOR JOISTS, RAFTERS, TRUSS,
ETC. SHALL VERTICALLY ALIGN AND BEAR
DIRECTLY ON EACH OTHER.
ROOF FRAMING:
1. ROOF DECKING: 15
32" APA RATED PLYWOOD OR
7/16" APA RATED OSB, 0.113 x 2-3/8" RING SHANK
NAILS, 4" AROUND PERIMETER OF DIAPHRAGM. 4"
EDGE & 4" FIELD NAIL PATTERN.
2. RIDGES TO BE 2x10 (UNO)
3. ALL HIPS TO BE 2x8 (UNO)
4. ALL RAFTERS TO BE 2x6 16"O.C. (UNO)
5. RAFTER TAILS SHALL BE A CONTINUOUS
MEMBER EXTENDING FROM RAFTER (NO SPLICE)
6. ALL SHINGLES SHALL BE 30 YEAR W/ ASTM D7158
CLASS H WITH 6 NAIL PER SHINGLE.
BRACE POINT
BW - BRACE TO WALL
BS - BRACE TO STRONGBACK
BB - BRACE TO BEAM
SHEAR WALLS:
STHD14 W/ (30) 16D SINKER NAILS IN STUD
PACK PER MANUFACTURERS
INSTRUCTIONS
OR
HDU5-SDS2.5 USE (14) 14"X21
2"SDS SCREWS
PER MANUFACTURERS INSTRUCTIONS
ALL SHEARWALLS SHALL EXTEND TO ROOF
DIAPHRAGM OR NEXT FLOOR DIAPHRAGM.
HOLD-DOWNS:
15/32" APA RATED PLYWOOD OR 7/16"
APA RATED OSB SHEATHING 6"
PERIMETER AND W/6" EDGE / 6" FIELD
NAIL PATTERN USING 0.113 x 2-3/8"
RING SHANK NAILS
SW1
15/32" APA RATED PLYWOOD OR 7/16"
APA RATED OSB SHEATHING 3"
PERIMETER AND W/3" EDGE / 6" FIELD
NAIL PATTERN USING 0.113 x 2-3/8"
RING SHANK NAILS
SW3
15/32" APA RATED PLYWOOD OR 7/16"
APA RATED OSB SHEATHING 4"
PERIMETER AND W/4" EDGE / 6" FIELD
NAIL PATTERN USING 0.113 x 2-3/8"
RING SHANK NAILS
SW4
HDU8-SDS2.5 USE (20) 14"X21
2"SDS SCREWS
PER MANUFACTURERS INSTRUCTIONS
NOTES
4"=1'-0"
AW
HUBBLE
RAFTER & SHEARWALL PLAN
######## (STANDARD)
Revisions:
PROJECT LOCATION OR ADDRESS:
CLIENT:
# DATE DESCRIPTION OF CHANGE
CHECKED BY:
SCALE:
DRAWN BY:
PROJECT #:
DATE:
CCH
NOTE: SIGNATURES VALID FOR ONE YEAR ONLY AFTER DATE OF SIGNATURES
ALL RIGHTS RESERVED. NO PART OF THIS DOCUMENT MAY BE REPRODUCED OR
UTILIZED IN ANY FORM WITHOUT PRIOR WRITTEN AUTHORIZATION OF “COBALT”.
CLIENT
ADDRESS
XXXXXXXX,TX 77XXX
XX-XXXX-XX
0 ISSUED FOR CONSTRUCTION
XX-XXXX-HRAP-ASH-SOG-XX/XX/2023
XX/XX/2023
THIS DRAWING IS A CONCEPTUAL PLAN AND IS NOT
INTENDED TO BE USED AS A SITE SPECIFIC PLAN NOR
SHALL IT BE USED FOR PERMITTING PURPOSES. SITE
SPECIFICS SHALL BE PREPARED ON A CASE-BY-CASE
BASIS AND ANY USE BEYOND THE AFOREMENTIONED
INTENT IS PROHIBITED.
® phone: 409-354-5925 email: info@cobalt-engineering.com
ENGINEERING AND INSPECTIONS, LLC
RAFTER PLAN (STANDARD)
SHEARWALL & HOLD-DOWN PLAN (STANDARD)
S-2.00
5X7 SAFEROOM
5X7 SAFEROOM
49 S.F.
+8'-0" CLG.
RIGHT
1/4
STEEL
5' -0
7'-0"
REARFRONT LEFT
1/4
1/ 4:
SL
O
PE
C.M.U. ON
CONCRETE SLAB
CONCRETE ROOF
FEMA 361 AND (2021)
ICC-500-2023 COMPLIANT
WALL VENT
FEMA 361 AND (2021)
ICC-500-2023 COMPLIANT
WALL VENT
ENGINEERING AND INSPECTIONS, LLC
409.354.5925
THIS SAFE ROOM PLAN IS FOR THE SOLE PURPOSE AND
USE FOR THE MISSISSIPPI DEVELOPMENT AUTHORITY
(MDA) PROGRAM SERVICES. AS SUCH, THIS DESIGN
MAY BE REPLICATED OR RECREATED FOR USE FOR
SITE SPECIFIC RECONSTRUCTION PLAN SETS. THIS
SPECIFIC DRAWING SHALL NOT BE USED FOR
PERMITTING.
SA
FE
R O
O M
(5 ' X
7X7 SAFEROOM
7X7 SAFEROOM
49 S.F.
+8'-0" CLG.
C.M.U. ON
CONCRETE SLAB
7' -0
7'-0"
RIGHT
1/4
REARFRONT LEFT
1/4
1/ 4:
SL
O
PE
STEEL
CONCRETE ROOF
FEMA 361 AND (2021)
ICC-500-2023 COMPLIANT
WALL VENT
FLOOR PLAN ROOF PLAN
FEMA 361 AND (2021)
ICC-500-2023 COMPLIANT
WALL VENT
ENGINEERING AND INSPECTIONS, LLC
409.354.5925
THIS SAFE ROOM PLAN IS FOR THE SOLE PURPOSE AND
USE FOR THE MISSISSIPPI DEVELOPMENT AUTHORITY
(MDA) PROGRAM SERVICES. AS SUCH, THIS DESIGN
MAY BE REPLICATED OR RECREATED FOR USE FOR
SITE SPECIFIC RECONSTRUCTION PLAN SETS. THIS
SPECIFIC DRAWING SHALL NOT BE USED FOR
PERMITTING.
SA
FE
R O
O M
(7 ' X
File details come from the government source that posted it. Updated .