This exhibit describes the Colorado River Service Unit (CRSU) facility requirements for medical imaging interpretation services. CRSU provides healthcare to eligible beneficiaries within the Colorado River Indian Tribes service area and requires contractor-provided interpretation services for three imaging modalities: Plain Film (X-Ray), Ultrasound (if available), and CT (if available). The Government will identify active modalities at the time of task order issuance. Service requirements, including hours of operation, will be established at the task-order level based on operational needs, with routine interpretation services anticipated during normal business hours.
The estimated annual workload spans five years (Base Year through Option Year 4) across three facility locations. Parker is the primary facility with 3,000 X-Ray interpretations, 600 CT interpretations, and 600 Ultrasound interpretations annually. Peach Springs requires 1,000 annual X-Ray interpretations, and Supai requires 500 annual X-Ray interpretations. Additionally, the contractor must support one HL7 interface for CRSU, with actual interface requirements subject to variation based on facility architecture and existing system configurations. Interface requirements include PACS integration, HL7 connectivity (if implemented), Vista Imaging compatibility, and compliance with required IHS cybersecurity and connectivity requirements. Facility-specific workflows, escalation procedures, and additional interface requirements will be identified by the ordering activity.
View the file
Other files
Show all 18
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
EXHIBIT C
COLORADO RIVER SERVICE UNIT (CRSU)
C.1 Facility Description
Colorado River Service Unit provides healthcare services to eligible beneficiaries within the Colorado River Indian Tribes service area.
C.2 Imaging Modalities
Contractor shall provide interpretation services for modalities available at the facility, including:
• Plain Film (X-Ray)
• Ultrasound (if available)
• CT (if available)
The Government will identify active modalities at time of task order issuance.
C.3 Service Hours
Service requirements shall be established at the task-order level based upon operational needs.
Routine interpretation services are anticipated during normal business hours.
C.4 Estimated Annual Workload
PARKER Base Year OY1 OY2 OY3 OY4
CT 600 600 600 600 600
X-Ray 3000 3000 3000 3000 3000 Ultrasound 600 600 600 600 600
PEACH
SPRINGS
X-Ray 1000 1000 1000 1000 1000
SUPAI
X-Ray 500 500 500 500 500
HL7
INTERFACE
The Government currently anticipates one (1) HL7 interface for CRSU. Actual interface requirements may vary based on facility architecture and existing system configurations.
Interface Requirements
Contractor shall support:
• PACS integration
• HL7 connectivity, if implemented
• Vista Imaging compatibility
• Required IHS cybersecurity and connectivity requirements
C.5 Site-Specific Requirements
Facility-specific workflows, escalation procedures, and interface requirements will be identified by the ordering activity.