Exhibit_B_Work-Write-Up_3dcda713.pdf

PDF 157 KB Posted

Attached to
NEW CONSTRUCTION Residential Home (Taylor-725 SW 3rd ST)
Solicitation number
ITB-CDS/240715A
Issued by
Marion County, Orlando City, Florida

About this file

This is a Work Write-Up exhibit for a new construction residential home project issued by the City of Ocala, Florida under ITB# FAC/240715A. The project involves the construction of a single-family residential home located at 725 SW 3rd Street, Ocala, Florida. A non-mandatory pre-bid meeting is scheduled for October 14, 2025 at 9:30 AM EST at the Taylor Residence site. The contractor must provide all labor, materials, and equipment necessary to complete construction in accordance with the Current Florida Building Code, Exhibit A (Scope of Work), Exhibit B (Work Write-up), and Exhibit C (Building Plans). The project contact is Mrs. Ashley Presley at apresley@ocalafl.gov or (352) 629-8364.

The work specifications include foundation and slab requirements with a minimum height of one foot above base flood elevation, exterior CMU/stucco walls with an eight-foot plate height, a 5/12 roof pitch with 30-year architectural shingles rated for 130 mph winds, interior construction with R-30 attic insulation and R-13-15 wall insulation, Energy Star-certified windows and appliances, plumbing fixtures (Delta brand specifications), a split-source heat pump HVAC system with minimum 16 SEER/SEER2 rating, waterproof vinyl plank flooring throughout, Sherwin Williams paint finishes, a new concrete driveway (approximately 750 square feet), ADA-compliant ramps and sidewalks, and landscaping with a minimum of 6500 square feet of sod. Award will be made on a lump-sum basis to the lowest bidder meeting all requirements, with all bids including direct and indirect costs.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

EXHIBIT B- Work Write- Up Contract ITB# FAC/240715A

This work includes but is not limited to the following:

• Foundation-Slab height shall be a minimum 1’ above base flood elevation. Contractor shall submit certificate verifying slab height.

• Plate Height – Eight feet (8’) - Typical

• Exterior Wall Construction – CMU/stucco

• Roof Pitch – 5/12

• Roof Sheathing – ½” CDX or OSB

• Roof Dry-In – Code Compliant water/moisture barrier– 100% of Roof

• Eve Drip – 2” Aluminum drip-edge, Color to be selected by Homeowner following Contract signing.

• Shingles – 30 yr. Architectural, 130 m.p.h. rated (Or better) (Provide written warranty, brand, model and color to owner and Rehab Inspector following installation).

• Shingle Color – To be Selected by Homeowner following Contract signing.

• Vent Penetrations - 4”-6” Bath Vent Boots (2 – Sized per Fan Requirement), 8-10” Range Hood

Vent Boot (1), Ridge Vent is to be “Shingle Over” (“Cobra Vent”) style. Boots/vents shall be color matched to shingles.

• Fascia / Soffit – Aluminum, woodgrain Fascia and vented aluminum soffit, typical (Color to be selected by Homeowner following Contract signing

• Interior Studs – Wood / #2 Spruce-Stud spacing 2x4@16” o.c.

• Insulation – R-30 Fiberglass Batt in attic (min.), R-13-15 Fiberglass Batt in exterior walls or ¾” R-

MAX (masonry) equal/better

• Exterior Wall Finish – Fiber cement siding/paint(frame), Stucco/paint(masonry)

• Front Entry Ceiling- Exterior drywall w/knockdown texture

• Windows – Single Hung, Colonial, White Vinyl, Low-E, Argon Filled, with grids in the glass and screens, Energy Star Certified for Florida.

• Entry Doors (Exterior Rated) – Steel or Fiberglass on rot-proof jams with rot proof exterior trim and Stainless-Steel Security Hinges, with door stops, ADA COMPLIANT THRESHOLE Typical o Front Entry – Inswing – 3’-0” x 6’-8”, 6-panel (or similar design) Fiberglass or Steel with Fan

Lite, Peephole Viewer, Model DS238, OR Equivalent and with Kwikset SmartKey Lever-style

ADA Keyed-Entry lockset and matching deadbolt in Brushed Nickle or Oil Rubbed Bronze finish.

o Rear Entry - Inswing – 3’-0” x 6’-8”, 6-panel (or similar design) Fiberglass with ½-light with up/down/tilt blinds in the glass with Kwikset SmartKey Lever-style ADA Keyed-Entry lockset and matching deadbolt in Brushed Nickle or Oil Rubbed Bronze finish.

o Storm Door – On front entry, install a full-light storm door with retractable window and screen. Use Larson Model # 14604032 OR substantially Similar with all necessary hardware, matching front entry door hardware and color.

• Interior Doors – Colonial style, 6 panel wood grain, hollow-core, pre-hung with Kwikset, ADA -lever style hardware (Privacy locks on bedrooms and bathrooms and Passage on other rooms, in

Brushed Nickel or Oil Rubbed Bronze to match Entry Doors and 2-1/4” colonial casing, typical. All sizes per plan.

• Interior Trim – All interior trim styles to match. Colonial style finger-jointed, Casing 2-1/4”, Base

3-1/4”

• Ceiling/walls – 1/2” Gypsum Lightweight Ceiling Board w/ knock down Texture.

• Electric Service – Overhead, 200 AMP Main Minimum

• Meter Enclosure – Per NEC and OEU “Metering Enclosure and Equipment Standards”

• Smoke/CO Detectors – Smoke detectors must be hard-wired and interconnected with non-serviceable 10-year battery back-ups.

• Light / Fan Switches/Receptacles` – Toggle Style typical (white)

• Doorbell-Standard Builder grade

• Lighting -ALL Light Fixtures and Ceiling Fans to be ENERGY Star Certified, (4000K +/- unless otherwise specified) o Exterior – Provide LED Motion Security Floodlights on each corner of the home. Front and

Rear Switched separately.

▪ Entry Doors – Standard Bracket mount fixtures with LED changeable type bulbs

▪ Recessed Exterior Fixtures – To be “Wet Location” approved, LED with white trim.

o Interior –

▪ Kitchen – Recessed Can fixtures to be LED Energy Star Certified

▪ Kitchen / Dining Area – LED Energy Star Certified Area Light suited for the location and service needed.

▪ Bathroom(s) – to have three (3) bulb tulip-style, LED fixtures or with changeable

LED bulbs.

• Ceiling Fan/LED Light Units – 44-inch to 52-inch in bedrooms, 52-inch in Living/Family room and bedrooms

▪ All fans have reverse air-flow option, Minimum 3000 CFM Capable Air movement.

▪ All fans-Give owner color choices

▪ All ceiling fan/Lights are to have changeable-type LED Bulbs/fixtures.

• Water and Sewer Connections - Provide and install completely new connections to City of Ocala

Water and Sewer Connections.

• Plumbing – ¼-turn Stops - Typical (Kitchen sink, Refrigerator/Ice Maker, Dishwasher, Bathroom vanities, Toilets, laundry supplies and hose bibs) o Kitchen: Double Basin Stainless Steel (33” X 22” X 8” Deep)

• Delta Classic Stainless 1-handle, High-arc faucet with separate pull-out sprayer o Bathroom(s): Delta Classic Tub and/or Shower Valve w/ Integrated Stops

• Delta Classic Chrome, Single lever shower trim

• Delta In2ition Chrome Shower Head, mounter at 80” to 84” A.F.F. – Typical with slide bar o (Model #75588 OR Equal)

• Delta Classic Chrome, Single lever Vanity Faucet – Typical

• Each tub/shower area to have recessed soap/shampoo niche shelves in each. Owner location choices

• White, American Standard Cadet Series, 2-piece, ADA/Comfort/Right

Height, “WaterSense Certified,” 1.28 GPF, Elongated Toilets w/ seat and lid–

Typical Both Bathrooms

• ADA Grab Bars w/ escutcheons (3) in all Showers, Tub/Shower Combos – 1

Large 36”- 42” on back wall and 1 (each) 12”- 18” Left and Right Sidewalls, vertical –Install adequate wood backing-Owner approved locations/Typical

• Install recessed, 3-shelf, mirrored medicine cabinets to the left or right of the vanity sink.

• Install the wall mirror, centered above each vanity sink.

• Install Towel bars in tub/shower area(s), and on the wall of the bathroom(s)

• Install toilet paper dispensers in most logical locations to service the commode

• Install towel hook or ring next to the vanity sinks in most logical location(s)

• Cabinets – All Cabinets to be solid wood/plywood construction, w/pulls, handles or knobs as appropriate.

o Kitchen

▪ Lower Cabinet units per plan, door and drawers, standard height. Cabinets shall contain 1 drawer stack.

▪ Upper Cabinet Units 30” +/- per plan w/matching box covering exhaust duct.

▪ Formica-type counter tops with integrated 4” backsplash per plans – typical(minimum) o Bathroom(s)

▪ Master 36” Counter height with solid surface top and 18” oval or integrated vanity sink

▪ Guest 36” Counter height with solid surface top and 18” oval or integrated vanity sink

• Closet Shelving – ClosetMaid Shelf type wire shelving typical in closets o All bedroom closets and above washer and dryer area ClosetMaid Shelf and Rod type o ClosetMaid Pantry/Close Mesh type Wire shelving typical in pantry/laundry/linen

• Mechanical – Split Air Source Heat Pump – Minimum System Requirements Per Current Florida

Building Codes, - Mechanical and FBC, Energy Conservation Code Requirements o Illuminated, Digital Thermostat Required, Matched/Compatible with HVAC System.

o 16 SEER/SEER2 minimum rating o Secondary “Wet-switch” in condensate line required.

o AHRI Certificate and Energy Calculations and Manual D & J Required. Provide additional copies to Rehab Inspector.

https://www.lowes.com/pl/Closetmaid--Wire-closet-shelves-Wire-closet-organizers-Closet-organization-Storage-organization/2350164646?refinement=4294965732 https://www.lowes.com/pl/Closetmaid--Wire-closet-shelves-Wire-closet-organizers-Closet-organization-Storage-organization/2350164646?refinement=4294965732 https://www.lowes.com/pl/Closetmaid--Wire-closet-shelves-Wire-closet-organizers-Closet-organization-Storage-organization/2350164646?refinement=4294965732

▪ In each Bathroom – Provide and install “Delta Breez Green Builder,” Model 80HLED

(OR Equivalent) Bathroom Exhaust Fans with 4-inch Semi-Rigid Aluminum Duct to

Roof Penetration. Fans to be run on dedicated GFCI Circuit with the LED Light on a separate switch.

▪ In Kitchen – Provide and install ridged metal duct for Microwave/Range Hood

Ventilation through the roof to exterior.

▪ In laundry install Dryerbox® type venting.

• Flooring – Waterproof Vinyl Plank Flooring Throughout (Owner to select Color from Contractor provided selections following contract signing. Lighter colors suggested) o Bathroom Floors – Waterproof Vinyl Plank Flooring o Roll-in Shower, to be Porcelain or Ceramic Tile.

• Bath Wall Tile-Ceramic to the ceiling with bullnose trim floor to ceiling.

• Appliances – All appliances (Frigidaire equal or better) to be Energy Star Certified (Except Range and Microwave) o Appliances to be black, white, or stainless

▪ Refrigerator/Freezer, 20 c.f. or larger

▪ 30-inch Smooth-top, Freestanding Electric Range with Self Cleaning Oven

▪ Dishwasher, top controls, provide all necessary power cords, drain, and supply hoses.

▪ 30-inch, Over-the -range Microwave Oven/Vent Hood, with Exterior ventilation.

▪ (Range, Refrigerator, Dishwasher and Microwave MUST be same Brand/matching model line and finish color)

• Paint – All primer(s) to be Sherwin Williams Multi-Purpose Interior/Exterior Latex Primer, Equal or Better. All Interior Paint to be Sherwin Williams ProMar 200, low/no VOC OR

Equal or Better. All Exterior Paint to be Sherwin Williams SuperPaint Equal or Better. Paint shall be applied with enough coats, free of trash and debris, in a uniform film, to cover, mask or obscure the substrate to which it is applied, or the colors underneath. Provide enough coats for a complete and even coverage without bleeding. All paintable surfaces shall be primed and painted.

o Interior

▪ Ceilings to be Flat White Ceiling Paint

▪ Wet/Damp areas to be Semi-Gloss finish

▪ All other areas to be Satin finish

▪ All trim to be Gloss finish o Exterior

▪ Ceilings (if paintable) to be Exterior Rated, Flat White Ceiling Paint

▪ Walls to be Satin

▪ All Trim to be Gloss finish

• Concrete Driveway - Provide and install a new concrete driveway and apron, location TBD.

Approximate allowance of 750 square feet at 4” thick.

• Sidewalk/ADA Ramps – Provide a concrete ramp/walk from home to driveway, location TBD. (Do not exceed 1:12 slope)

• Landscaping – Provide a minimum of 6500 square feet of sod, Argentine Bahia, around home (to include right of way) after final grade. Sod shall be tightly laid and rolled. Any dead sod shall be replaced. Remainder of lot shall be seeded (Argentine Bahia seed), protected with hay, and watered until accepted. Standard USPS mailbox, black, on 4x4 pt post w/house numbers on the side. For lots smaller than 6500 square ft, the entire lot shall be sodded.

• House Numbers-Code approved. Shall not be peel and stick type. In an approved location.

• Elevations-Finished floor elevation shall be minimum 1’ above the highest spot in the road in front of the home. For flood zones, the elevation shall be minimum 1’ above base flood elevation.

Contractor shall include a survey of the finished floor elevation, proposed spot elevations and flow arrows in the site plan to indicate the direction of drainage flow. A final plot plan with finished floor elevation, spot elevations and flow arrows must be submitted to stormwater division before CO is issued. Finished floor elevation should also show in relation to the crown of the road.

File details come from the government source that posted it. Updated .