This document contains a solicitation for upgrading emergency electrical systems at the Gulf Coast Veterans Health Care System in Biloxi, Mississippi. The solicitation will be issued as a 100% set-aside for service-disabled veteran-owned small businesses through request for proposal procedures. Interested offerors must check the beta.SAM.gov website for the solicitation release on or around January 25, 2021, with proposals due approximately 30 days later on February 25, 2021. The contract award is anticipated approximately 30 days after receipt of proposals. The contract performance period is 120 calendar days after notice to proceed. The construction cost range for the project is between $500,000 and $1 million. Offerors must be registered and verified in the VetBiz Registry and System for Award Management databases to be considered for award.

View the file

Other files

File Type Posted
36C25621R0055 0004.docx DOCX document
WD General Decision No MS20210050 02-12-2021.pdf PDF
Register containing all RFI Inquiries _ Responses.pdf PDF
36C25621R0055 0003.docx DOCX document
36C25621R0055 0002.docx DOCX document
Site Visit Sign-In Sheets - Proj 520-22-108.pdf PDF
36C25621R0055 0001.docx DOCX document
Solicitaiton 36C25621R0055.docx DOCX document
260511 Requirements for Electrical Installations.doc DOC document
EXHIBIT E SURETY FORM.docx DOCX document
EXHIBIT F REQUEST FOR INFORMATION FORM.docx DOCX document
SITE VISIT MAP Biloxi VA.pdf PDF
Dwg No EP110 Power Plan Level 1 Utility Plant Addition Utility Upgrades Phase 2.pdf PDF
EXHIBIT D CONTRACTOR EVALUATION FORM CONSTRUCTION SAFETY.docx DOCX document
Dwg No E-601 One Line Diagram Utility Plant Addition - Utility Upgrades Phase 2.pdf PDF
Dwg No E-401 Large Scale Plans - Mental Health Facility.pdf PDF
Dwg No EP-111 Partial Bldg Nos 2 3 19 Power Plan Level 1 Utility Upgrades Phase 2.pdf PDF
EXHIBIT C SUBCONTRACTOR INFORMATION AND CONSENT.docx DOCX document
Test Report Deficiencies Biloxi VA.pdf PDF
WD General Decision No MS20210050 01-01-2021.docx DOCX document
Dwg No ES-604 15KV Primary Distr One Line Diagram - Utility Upgrades Phase 2.pdf PDF
Relay Testing Report Biloxi VA.pdf PDF
ICRA 520-22-108.pdf PDF
262726 Wiring Devices.doc DOC document
EXHIBIT B PAST AND PRESENT PERFORMANCE QUESTIONNAIRE.docx DOCX document
260526 Grounding and Bonding for Electrical Systems.doc DOC document
Dwg No I-E1 Electrical Plot Plan Phasing Modernize Various Bldgs Bldgs 1 5 19 and 53.pdf PDF
Dwg No E-601 One Line Diagram - Mental Health Facility.pdf PDF
010000 General Requirements.docx DOCX document
36C25621R0055_1.docx DOCX document
263623 Automatic Transfer Switches.docx DOCX document
260521 Low Voltage Electrical Power Conductors and Cables 600 Volts and Below.doc DOC document
Show all 32

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FOR OFFICIAL USE ONLY

Source Selection Sensitive Information—See FAR 2.101 & 3.104 Project 520-22-108 Upgrade Emergency Electrical Systems, Biloxi 36C25621R0055

EXHIBIT A

PERFORMANCE RELEVANCY SURVEY

Offeror Name/Company

PART 1. CONTRACT REFERENCES: Provide the following information requested in this format for each of the projects/contracts you intend to have considered for evaluation. Projects shall have been completed no more than 5 years prior to the solicitation issue date. Provide all information requested regarding YOUR PERFORMANCE on the contracts you elect to reference.

Project Submittal #___________________ (NOTE: Offerors allowed NO MORE than 5 projects- offerors to make appropriate copies) Project/Contract Title: ________________________________ Contract Number/Task Order Number:_______________________ Location of Project:__________________________________ Description of Effort as Prime ( ) or Subcontractor ( ) Original Contract Value: $________________________ Current/completed Contract Value: $_________________________ Was project completed on time: Yes ( ) No ( ) Start date: ___________________ End date:_________________ Reason for delay if applicable:__________________________________________________ Any liquidated damages: Yes ( ) No ( ) CPARS available: Yes ( ) No ( ) (NOTE: Offeror can provide CPARS with proposal; however, the questionnaire has more detailed questions.)

Provide detailed description of the work performed under the contract and describe why you believe the work is VERY REVELANT, RELEVANT, or SEMI-RELEVANT. (Circle one)

Very Relevant Present/past performance effort involved essentially the same scope and magnitude of effort and complexities this solicitation requires.

Relevant Present/past performance effort involved similar scope and magnitude of effort and complexities this solicitation requires.

Somewhat Relevant Present/past performance effort involved some of the scope and magnitude of effort and complexities this solicitation requires.

Relevance detailed description of project to include work by subcontractors:

Point of Contact of Reference on project (who you are sending questionnaire/survey to):

Name: ________________________ Title: ________________________ Agency: ________________________ Email: ________________________ Phone: ________________________ POTENTIAL OFFERORS: IT IS YOUR RESPONSIBILITY TO FOLLOW-UP WITH YOUR REFERENCES IN SUBMITTING QUESTIONNAIRES PRIOR TO THE CLOSE OF THE SOLICITATION.

PART 2. NOT RELATED TO PART 1: Additional offeror information required, but not project specific. THIS INFORMATION NEED ONLY BE PROVIDED ONCE IN YOUR SUBMISSION PACKAGE.

Offeror representative providing the below information:_______________________

1. Provide information regarding the assessment of liquidated damages on any contracts within the last five years. (Frequency, circumstances, severity of problem, etc.)

2. Offerors are strongly encouraged to include with their proposals information on problems encountered on any relevant projects and the specific corrective actions taken to remedy the problems. Furthermore, please provide explanation of any marginal ratings in CPARS if applicable:

3. Other Past Performance Considerations. Information provided shall be limited to the period starting five years prior to the solicitation release date and may include the following:

a. Professional/Industry awards (Identify award type, date of award and copy of certificate if applicable), Letters of appreciation, recognition or commendations

b. Discuss unique skills and accomplishments (Explain unique skills and/or accomplishments and provide supporting information for verification).

4. Address any technical areas about this project you consider uniquely relevant to this solicitation.

· Descriptions must address the following:

· Describe the specific elements of the work performed by your firm.

· Indicate what elements of work were performed by your major subcontractors and indicate if those same subcontractors will be used on this project.