Ex. B Agency Special Requirements.pdf

PDF 2 MB Posted

Attached to
General Services Administration (GSA) seeks to lease office space in Phoenix, AZ
Solicitation number
3AZ0267
Issued by

About this file

This document is a detailed Special Requirements document for the Phoenix Field Office of U.S. Citizenship and Immigration Services (USCIS), Version 3.0 dated January 2020. The document provides comprehensive architectural and design specifications for a USCIS field office facility, covering everything from building design and branding to specific technical requirements for individual room types. Key design requirements include locating the space in a modern office or business park with Class A or B office space, creating separate public and employee entrances, and ensuring the facility meets environmental stewardship standards like LEED Interior Design and Construction certification.

The document specifies precise technical requirements for various spaces, including interview rooms, computer rooms, waiting areas, restrooms, and security screening zones. Critical technical specifications include wall and ceiling construction types, electrical and data drop configurations, HVAC zoning, lighting standards, flooring materials, and security system requirements. Notably, the document mandates specific acoustic ratings for sensitive spaces like the HSDN/TALON room, requires independent mechanical systems for certain areas, and details security infrastructure such as video surveillance, duress alarms, and access control systems. The specifications are extremely granular, providing exact requirements for everything from electrical outlet placement to corner guard materials, reflecting USCIS's comprehensive approach to facility design and functionality.

View the file

Other files

Show all 22

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Phoenix Field Office Special Requirements

USCIS Facilities Management Division Version 3 – January 2020

Version 3.0 - January 2020 Page 2 of 21

Table of Contents Overview

Building Design Branding

Lady Liberty Exterior Signage Interior Signage Color Palettes

Building Hours of Operation Test-Fit Layout

Field Office Director’s Area Immigration Services Immigration Services Support Joint Use and Office Support Space General Notes

Environmental Considerations Typical Design Layouts

HSDN/TALON Room Configuration Showers Wall Partition Types

Schedules Ceilings Doors Electrical - Power and Data Flooring HVAC - Mechanical Lighting Miscellaneous Security Walls

Version 3.0 - January 2020 Page 3 of 21

Overview

Building Design

The U.S. Citizenship and Immigration Services (USCIS) maintain a strong tradition of public building design that reflects the highly respected stature of the U.S. Government. All USCIS facilities should embrace and illustrate this principle and present a building or office environment that exhibits fiscal prudence and efficiency of the public’s money, as well as, contribute to the vitality of the surrounding area.

USCIS space shall be located in an office, research, technology, or business park that is modern in design with a campus-like atmosphere; and be in a modern office building that is professional and prestigious in appearance with the surrounding development well maintained and in consonance with a professional image. The space shall be within an appropriately zoned district, i.e. Central Business District, Business Park, Commercial, or Office. Buildings located within any type of Manufacturing, Industrial, Warehouse, Retail or similar zones will not be accepted.

Space shall be BOMA Class “A” or Class “B” Office space with no exceptions (See General Notes for definitions). USCIS space shall be located within a ½ walkable mile to public transportation with one or more bus stops or combination of bus and train stops. Adequate eating facilities shall be located within the immediate vicinity. Other services such as retail shops, cleaners, banks, etc. shall also be located within the immediate vicinity.

USCIS prefers single floor occupancy. If it is determined that USCIS space can be located on more than one story, the public entry, security, information, records, and ceremony rooms should remain on the same floor serving most public functions. The remaining USCIS required space will be planned accordingly to include proper and separate access (including elevators) for the public and for employees.

The separation of the Public and Employee space will be an important aspect of this facility. All visitors shall enter through a single, well-defined, secure entrance. The entrance sequence will include a public entry that provides for protection from the weather while waiting for the security screening. USCIS employs an online appointment scheduling system, so visitors will come in a consistent stream throughout the day. The busiest time will be first thing in the morning when the first round of customers arrive at the same time requiring the process to accommodate approximately 150 people. The employees will enter through a separate entrance

Branding

Branding is incorporated throughout USCIS spaces and includes Lady Liberty, interior signage, and exterior signage. Branding is further emphasized through the use of color palettes.

Version 3.0 - January 2020 Page 4 of 21

Lady Liberty

This image should be provided on the exterior perimeter of the building near the public entry or within the public lobby space. Sizing, color, and material application will be determined during the design.

Exterior Signage

Signage must be provided on the exterior of the building or in the entrance area to the USCIS space. Additionally, USCIS may include a freestanding monument sign. The proposed sign location should be located on the site plan or building elevation plans. Based on the Offeror’s location, additional exterior directional signage may be required for campus or professional park environments. (Dimension’s utilized in the following layout are for scaling purposes only.

Interior Signage

USCIS provides and maintains agency specific interior signage requirements. The Government will provide signage specifications to the Offeror to provide and maintain signage consistency throughout USCIS spaces.

Color Palettes

USCIS color palettes will be incorporated into the space. The Offeror’s architect will work with the USCIS PM to establish the color palette during design.

USCIS COLOR PALETTES

DARK ACCENT MEDIUM ACCENT LIGHT ACCENT WHITE BASE

Benjamin Moore Benjamin Moore Benjamin Moore Benjamin Moore

Orange Tone Masada (AF-220 Classic Caramel (1118) Putnam (HC-39) Elephant Tusk (OC-8)

Blue Tone Blue Danube (2062-30) Philadelphia Cream (HC-30) Yellow Freeze (2020-70) Ocean Air (2123-50)

Red Tone Apache Red (1295) Secret (AF-170) Stonington Gray (HC-170) White Dove (OC-17)

Green Tone Guilford Green (HC-116) Chambourd (AF-645) Lancaster Whitewash (HC-174) White Dove (OC-17)

Violet Tone Mint Violet (1252) Stardust (2108-40) Tapestry (975) White Dove (OC-17)

Tan/Blue Tone Quincy Tan (HC-25) Montpeliar (AF-555) Stonington Gray (HC-170 Seapearl (OC-19)

Version 3.0 - January 2020 Page 5 of 21

Building Hours of Operation

The entire building is considered operational from 6:00am to 5:30pm, five days per week (except for Federal Holidays. All USCIS space must be capable of having HVAC services on Saturdays. The Computer LAN Room and any wire/telephone closets will require 24/7 HVAC services. USCIS recognizes that utility costs outside of normal operations hours will be paid for as overtime utilities through Government reimbursable work authorization funding.

Test-Fit Layout

A test fit layout with the necessary office suite area adjacencies must be provided to demonstrate the Offeror’s intent to meet the USCIS requirements. This test fit should follow the design criteria to meet adjacencies and room requirements. When designing office square footage requirements less than 20,000 square feet a single floor design will be required. If the office square footages range from 20,000 to 40,000 square feet a contiguous two-floor design can be considered. If the office is more than 40,000 square feet, a contiguous three-floor design can be considered. When a multi-floor occupancy is being offered, vertical circulation will be required for employees.

Field Office Director’s Area

The Field Office Director (FOD) is the individual who is responsible for overseeing the operations of the USCIS Field Office location. This office should occupy a prominent area within the facility. The FOD Suite will consist of private offices planned with open office workstations including a waiting area, conference room (typically adjacent to the FOD office), copy area, storage, and circulation space.

ROOM FLOOR WALL DOOR CEILING LIGHTING HVAC EDV MISC SEC

Field Office Director F1 W1 D3 C1 L1 H1 E1 S4

Private Offices F1 W1 D1 C1 L1 H1 E1

Workstations F1 N/A N/A C1 L1 H1 E4

Conference Room F1 W1 D2 C1 L2 H2 E3 M1

Computer/ LAN Room F6 W6 D4 C4 L3 H7 E17 M10 S3, S6

Computer Setup and Storage F6 W3 D3 C1 L3 H1 E16

Copier Area F1 W2 N/A C1 L3 H1 E5 M2

Open Office Space/Circulation F1 W2 D3 C1 L1 H1 E4 S5

Version 3.0 - January 2020 Page 6 of 21

Immigration Services

The Immigration Services Division is responsible for interviewing, testing and granting individual’s citizenship in the United States of America as well as making adjustments to an immigrant’s current status. They are also responsible for providing information and forms to persons seeking legal immigration. The design of this area should reflect the importance of the process and provide a space that is comfortable for both the customer and employee.

The preferred design solution would have all office areas co-located on a single floor with the waiting room. The file room and open office space where clerical and administrative functions are performed should be adjacent or central to this Division’s offices. Public and employee circulation areas must be separate.

Interview Rooms will separate USCIS public and secure spaces. These rooms should be welcoming and open while maintaining the security and privacy to both customers and USCIS employees.

Private Office F1 W1 D1 C1 L1 H1 E2 M4

Interview Room F1 W1 D6 C1 L1 H1 E2 M3, M4 S4

Workstations F1 N/A N/A C1 L1 H1 E4

Copier Area F1 W2 N/A C1 L3 H1 E5 M2

A-File Room F1/F3 W3 D4 C1 L3 H1 E9 M17

VTC Conference Room F1 W1 D2 C1 L2 H2 E3 M1

Non-VTC Conference Room F1 W1 D2 C1 L2 H2 E3 M1

Open Office Space/Circulation F1 W2 D3 C1 L1 H1 E4 M4

Waiting Room F4 W4 D3/D5 C2 L1 H3 E8 M5 S1

Naturalization/Conference Room F1 W1 D1 C3 L2 H3 E14 M1

Naturalization Prep Room F1 W3 D4 C1 L1 H1 E7

Chair, Table and AV Storage F1 W2 D7 C1 L5 H1 E13

HUB Room F1/F3 W3 D4 C1 L3 H1 E6 M17

Immigration Services Support

The Immigration Services Support Division is where all files and records regarding applicants are maintained. The flooring must be capable of supporting a live load of 100lbs per square foot. File transfers between the Records Division and other Divisions typically involve the use of wheeled carts.

Private Office F1 W1 D1 C1 L1 H1 E2

Workstations F1 N/A N/A C1 L1 H1 E4

A-File Room F1/F3 W3 D4 C1 L3 H1 E9 M17

FDNS A-File Room F1/F3 W3 D4 C1 L3 H1 E9 M17

Version 3.0 - January 2020 Page 7 of 21

Joint Use and Office Support Space

The Joint Use and Office Support Space include areas that are shared by all Divisions within the office. The public entry will include weather vestibule and a security screening area. The security screening area, where guards will be posted, will include a walk-through metal detector and an x-ray machine.

The Naturalization Ceremony Room is where immigrants will be granted their U.S. citizenship. This room may also be used for multipurpose activities including conferences and training. The HVAC system should be designed to accommodate these occupant loads. A stage will also be included in the design of this room.

In addition to the employee restrooms, a set of public restrooms should be located adjacent to the lobby space.

A mail room, located near the loading dock/receiving area, will require a dedicated exhaust system and will also include an additional x-ray machine for the screening of packages.

Break Room F5 W1 D2 C1 L1 H6 E15 M8

Chair, Table & A/V Storage F1 W2 D7 C1 L1 H1 E13

Bulk Storage F3 W3 D9 C5 L5 H1 E9 M9

PIV Room F1 W2 D3 C1 L1 H1 E6

Receiving Area F3 W3 D9 C5 L5 H1 E9

Lactation Room F1/F5 W2 D11 C1 L1 H1 E19 M19

Showers (Men and Women) F7 W7 D10 C6 L6 H1 E22 M13

Mail Room (including X-ray) F2 W8 D9 C1 L3 H8 E18 M12 S7,S8

Remote Wiring Closet F6 W6 D4 C4 L3 H9 E20 M11

Security Queuing Space F8 W3 D3/D5 C2 L1 H3 E21 M14 S1/S2

Security Screening Stations F8 W3 D3/D5 C2 L1 H3 E21 M14 S1/S2

HSDN/TALON Room F1 W5 D8 C7 L1 H5 E12

Weather Vestibule F8 W3 D3/D5 C2 L1 H3 E21 M14 S1/S2

Visitor Family Restroom F7 W7 D10 C6 L6 H1 E22 M16

Visitor Men’s Restroom F7 W7 D10 C6 L6 H1 E22 M16

Visitor Women’s Restroom F7 W7 D10 C6 L6 H1 E22 M16

Version 3.0 - January 2020 Page 8 of 21

General Notes

In the event a conflict exists between the GSA Request for Lease Proposal (RLP) and the USCIS Special Requirements, the USCIS Special Requirements shall prevail.

1. Building Classification – USCIS requires all buildings to be either Class A or Class B, no exceptions.

a. Class A - Most prestigious buildings competing for premier office users with rents above average for the area. Buildings have high quality standard finishes, state of the art systems, exceptional accessibility and a definite market presence.

b. Class B - Buildings competing for a wide range of users with rents in the average range for the area. Building finishes are fair to good for the area. Building finishes are fair to good for the area and systems are adequate, but the building does not compete with Class A at the same price.

2. Building Entrance – Wherever possible there should be two entrances to USCIS space. One entrance for employees and one entrance for visitors.

3. Direct/Indirect Light Fixtures – Light fixtures shall be direct/indirect and be capable of providing 30-foot candles (unless otherwise noted) of light at work surface height (30"AFF). Lamp color shall be maintained at 3500K and the CRI (Color Rendition Index) must be maintained at a minimum of 80 for the term of the lease unless an alternative light color is approved by the USCIS Facilities Space Management Branch (FSMB). The Lessor shall ensure that the cost of the shell lighting specified in the RLP needs to be subtracted from the total lighting cost in the Tenant Improvement pricing.

4. Sidelight Assemblies – Typical sidelight assemblies as required shall be integral with the door frame. If transoms and additional glazing adjacent to the door frame are to be specified in order to achieve LEED points for day-lighting, they should also be integral to the door frame and approved by FSMB prior to being included in the project design.

5. Surge Protective Devices(s) (SPD) – SPD will be required and must be located prior to the building’s main distribution panel (or at least before the panels/service serving the Government's leased space). The Lessor shall be responsible for replacement of MX modules when a failure occurs and the system indicates the module is defective. The USCIS Information Technology (IT) staff will periodically inspect LED indicator lights and contact GSA/Lessor when LED indicators to show replacement is necessary. The Lessor shall be responsible for providing, installing, and maintaining this system throughout the term of the lease.

6. Electronic Security System (ESS) – The Lessor shall furnish and install an operational ESS. The Lessor will maintain the systems during the one year warranty listed to the installer which commences on the date of the facility acceptance. The Government will own and maintain all installed equipment upon expiration of the one year warranty. The ESS will comprise of an HSPD12 Compliant Access Control System (ACS), Intrusion Detection System (IDS), and Internet Protocol Video Surveillance System (IPVSS) that will be capable of operating on an integrated standalone platform which can provide USCIS with the ability to access, monitor, administer and control of all three systems through a single client. The costs of the ESS shall be paid by the Government through the Tenant Improvement Allowance. The complete requirements for the electronic security systems are provided in the attached USCIS Facility Security Specific Requirements (FSSR) for Electronic Security Systems. Refer to paragraph 7.a for POTS line requirements.

7. Magnetometer and X-ray Machine(s) – USCIS will provide security equipment to be located within lobby security screening and mailroom. The Lessor shall be responsible for the coordination of the power and data to the equipment.

8. Building Services – Demarcation (Voice/Data Requirements) – Provide two (2) – 4-inch conduits (EMT Metallic raceway – inside) with pull strings from the Main building demarcation routed directly in the USCIS LAN/Computer Room. The separate conduit raceways shall be utilized for copper, fiber optic, and CATV service into the facility based on circuit requests/orders submitted by USCIS. Indicated below shall be utilized to determine site requirements. (Note: For new facilities, provide three (3) – 4 inch conduits (PVC – Schedule 80 outside) with pull strings from the Main building demarcation within the facility directly to the Service Provider Utilities for copper, fiber optic, CATV, etc. at telephone pole, enclosure, etc. on the exterior building. Coordination will be required with local Service Providers to identify locations).

a. Voice circuit - copper requirement – The voice lines and circuit requirements shall meet the staffing criteria, which shall utilize copper to deliver service to the Building Demarcation on existing or upgraded infrastructure for implementation that includes approximately (4) analog lines (POTS) and Primary Rate Interface (PRI’s) (2) for voice applications. Leased construction build-out per lease will require the coordination by the lessor with the local service provider to install the copper cable requirement to support facility for USCIS voice requirement installation. NOTE: The lessor shall be responsible for shell cost for providing the required amount of analog lines (3) which will connect to the Federal Protective Service Mega Center, LAN Room Environmental Alarm, the local fire alarm, life safety, and any other systems along with the monthly reoccurring costs included in the lease agreement. See Reference E17.

b. Data circuit - copper requirement – The data circuit requirement shall utilize copper to deliver service to the Facility Demarcation on existing or upgraded infrastructure for implementation of one analog line, Public Switched Telephone Network (PSTN), for monitoring network. Leased construction build-out will require the coordination by the lessor with the local service provider to install the copper cable requirement to support USCIS network deployment per lease agreement.

AND

c. Data circuit - fiber optic requirement – For office and staffing requirements, the data circuit types shall be (2) 1Gig dedicated access circuits with one having an IPS Port of 1Gig and the other having a VPN port of 500Mbps, which requires that the existing fiber optic cable in the facility shall be utilized to support the network. If fiber cable does not exist within the facility or meet needed circuit requirement, coordination is required by the Lessor and the local service provider to install accordingly or upgraded infrastructure included per lease agreement for implementation with the site upgrades to support the USCIS network deployment. Note with existing buildings – The location within the facility where the building demarcation resides (telephone room, electrical closet, etc.) may require site upgrades that may include, but not limited to, the installation of electrical outlets (typically two (2) dedicated L5-15R's or requested equivalent), plywood backing, grounding to the Main Electrical Service, busbar, etc., as part of the Shell requirement.

Version 3.0 - January 2020 Page 9 of 21

9. Cable Management (Data/Voice Cabling) – The Lessor shall be responsible for the installation of the data and voice cabling.

Please refer to the USCIS Structured Cabling Plant Standards attached with the RLP. Each drop location shall consist of two data Category 6 white (2D) plenum cables for each office, workstation or other location indicated during the design phase to support network and voice applications. A wall phone location shall consist of one voice Category 6 white (1V) plenum cable. The Lessor shall be responsible for providing 19” standalone equipment racks with 10” double-sided vertical managers and patch panels for phone and data punch downs along with wire management, shelves, PDU’s, and ladder runway above racks in the LAN/Computer Room as highlighted in the USCIS Structured Cabling Plant Standards. A combination of cable basket trays and J-hooks shall be used to distribute the data/voice cabling throughout the building. If quantity exceeds 100 cables, basket trays shall be coordinated with the USCIS Project Manager in FSMB during the 30% construction drawing plan review. Cable trays (basket and ladder) shall be installed per manufacturer’s instruction and be coordinated with mechanical ducts, sprinklers, plumbing, etc. to ensure a 12” clearance above the tray from any obstructions. The cost of this work shall be paid by the Government through the Tenant Improvement Allowance. Upon final cost reconciliation of the project, the cost of the data and voice cabling shall be provided to the Government for USCIS budgetary purposes. This work (materials and labor) shall be warranted for the full term of the lease.

10. Wireless & Overhead Paging Application – The installation requirements for the USCIS Wireless Application throughout the facility will be included in the build-out of the project. Wireless and overhead paging drop locations will be AFC throughout the facility, with each location consisting of two data Category 6 white (2D) plenum cables. The requirements include plenum cabling, surface boxes, ceiling or wall mounted components, patch panels, wire management, conductivity/termination hardware, patch cables, etc., along with installation labor which will be typically specified in a supplemental attached statement of work (SOW) associated with the USCIS Structured Cable Plant Standards document. Site specific details will be included in the SOW for the requested installation and components to comply with the facility requirements. All AP's (Access Points) and speakers will be provided and installed by the Government following the acceptance and are NOT included with the TI.

11. Dumpsters (Post Acceptance) - Lessor to provide two (2) 6-yd dumpsters (estimated) for 60 calendar days, starting one (1) week prior to estimated USCIS/GSA site acceptance (date TBD). One (1) dumpster will be for trash disposal and one (1) dumpster will be for recycling disposal. Lessor has option of providing existing on-site dumpsters or providing temporary dumpsters. If temporary dumpsters are needed, Lessor is responsible for coordinating size, delivery and placement of dumpsters with GSA / USCIS prior to delivery and emptying dumpsters as needed throughout the 60 calendar day period.

12. Electrical Circuits – Dedicated circuits will be required in copier areas, HSDN (TALON) Room, security screening lobby and also in the break room. Dedicated outlets shall be a different color than the building standard. Further information and locations will be provided during design.

13. Standard Duplex Electrical/Data Drop Installations – Electrical outlets and data drops shall be installed per the industry standard;

18” Above Finished Floor (AFF).

14. Corner Guards – USCIS requires corner guards to be installed throughout the facility. Corner guards should be at least 4’-0” high and placement will be determined during design. At a minimum, they will be placed in high traffic areas. The corner guards should be stainless steel or high-impact vinyl. Manufacturer to be InPro or equal.

15. Systems Furniture Electrical Circuit Configuration – USCIS utilizes systems furniture workstations in open office space. The USCIS systems furniture vendor will provide the electrical circuit configuration during the design phase. The furniture vendor will provide the necessary electrical whips but it will be the responsibility of the Lessor’s electrical contractor to install the power/data connections.

16. E-Verify – The Offeror's contractors, subcontractors, cleaning staff and other employees having access to the facility both before and post occupancy must comply with Federal Acquisition Regulation 52.222-54 Employment Eligibility Verification. Only those individuals legally authorized to work in the United States are permitted to be employed either directly or indirectly by the Offeror. Information on registration for the use of the E-Verify program can be obtained via the internet at the Department of homeland Security Web site:

http//www.usics.gov/e-verify.

17. Security Clearances – USCIS is installing HSPD12 Compliant Access Control Systems in all USCIS Facilities. PIV Access will be required by all contract staff to include the lessor contract staff and his/her designees, lessor’s maintenance team and custodian/janitorial staff. Once USCIS has taken occupancy of the space, it is required that all contractors, janitorial and lessor staff requiring routine access to the USCIS space will have completed the required NACI security background check as mandated by HSPD12 for unescorted access during normal working hours. The Government will facilitate, monitor compliance and pay for all required NACI security backgrounds checks for the duration of the lease.

18. Door Hardware and Keying Control – USCIS has specific requirements for all door hardware, keying, lockset cores and the control of such. The Lessor shall review and comply with the requirements listed in this document as well as the USCIS Facility Security Specific Requirements. The specific master keying plan will be developed during the design. The implementation and execution of the final plan will be the Lessor’s responsibility. The Lessor shall provide a minimum of 3 copies of each lockset key. USCIS will control all keys. The Lessor is responsible for providing and installing a securable key storage box within the USICS space for the storage and/or control of all keys.

19. Automatic Door Openers – automatic door openers are required on any entrance door into USCIS space, restroom door and any door that may separate the lobby and waiting room.

20. Fire Alarm System (FAS) – The Lessor shall provide, install and maintain a compliant FAS for any building(s) which is occupied by USCIS. The FAS shall be complaint with the space’s intended use and meet all applicable NFPA while also meeting all requirements of the local authority having jurisdiction. If the GSA lease requirements and/or the local building codes require a complaint system as part of the building shell, those costs will be included with the shell rent. In this case USCIS will only focus on what is needed for the tenant improvement (TI) fit out and its integration with the shell FAS.

21. Mass Notification System (MNS) – As part of the tenant improvements, USCIS will require the design, installation and maintenance of a mass notification system for any space occupied by USCIS. The system and its components will be integrated with the installed FAS. The system and its components shall be installed to comply with NFPA codes and all requirements of the local authority having jurisdiction. The lay-out and placement for all components will be detailed during the design development phase of the scope of work.

Version 3.0 - January 2020 Page 10 of 21

At a minimum the MNS shall include eight (8) pre-recorded messages, two (2) activation panels with manual voice override and the ability to accept recorded .WAV files at a later date.

22. Loading Area and Freight Elevators – the space will require a loading and unloading zone for pallet sized deliveries. Ground level deliveries are acceptable assuming there is an easily accessible route to the building and freight elevators. Path to the freight elevator must have corridors that allow for the moving/turning of a pallet and pallet jack. The door opening width for the elevator cab must be a minimum of 44” and the cab must be deep enough to allow for a standard pallet sized load to fit. Successful offeror must demonstrate how this requirement will be met and acceptability of the plan will need to be approved by USCIS and GSA.

23. Accompanying Attachments

a. USCIS Facility Security Specific Requirements

b. USCIS Computer and Telephone Room Standards

c. USICS Structured Cable Plant Standards

d. USCIS Audiovisual Standards

e. USCIS Signage Standards

Environmental Considerations The U.S. Citizenship and Immigration Services make a strong commitment to environmental stewardship. The Offeror should comply with the following requirements which can also be found within the GSA RLP.

1. LEED Certification – The Offeror shall obtain LEED: Interior Design and Construction ( ID+C) at a minimum.

2. Compliances - The Offeror shall comply to the extent feasible with the Resource Conservation and Recovery Act (RCRA), Section

6002, 1976. The Offeror shall use recycled content products as indicated in the lease and as designated by the U.S. Environmental Protection Agency (EPA) in the Comprehensive Procurement Guidelines (CPG), 40 CFR Part 247, and its accompanying Recovered Materials Advisory Notice (RMAN).

3. Preferable Products - The use of environmentally preferable products and materials is encouraged in addition to the consideration of the lifecycle analysis of the product to the initial cost. Some examples may include janitorial cleaning products packaged ecologically, products and equipment considered environmentally beneficial, recycled products that are phosphate free; non-corrosive;

nonflammable; fully biodegradable and paper products with recycled content conforming to EPA's CPG.

4. Construction Waste - Prior to construction commencement, the Offeror shall submit a proposed plan following industry standards to recycle construction waste. The plan shall quantify material diversion goals and maximize the materials to be recycled and/or salvaged (at least 50 percent) from construction, demolition, and packaging debris.

5. Recycling – A building recycling service plan annotating recycling area(s) as part of DID’s should be reflected on CD submission. For leased space greater than 10,000 square feet with a term longer than six months, the Offeror shall establish a recycling program for (at a minimum) paper, corrugated cardboard, glass, plastics, and metals where local markets for recovered materials exist. An appropriately sized recycling area (2 SF per 1,000 SF of gross area) should be designed for collection and storage of recycling materials. Telecom rooms are not acceptable as recycling space. The Government, upon request, may request additional information concerning the recycling programs maintained in the building the leased space.

6. Energy Star – The Offeror shall achieve Energy Star rating for new construction. The Offeror is encouraged to purchase at least 50 percent of the Government tenant’s electricity from renewable sources.

7. Landscaping – As required, the Offeror must provide landscape management practices which avoids or minimizes the use of fertilizer and pesticides; prohibits the use of the 2,4-Dichlorophenoxyacetic Acid (2,4-D) herbicide and organophosphates; composted/recycled all yard waste; utilizing landscaping products with recycled content as required by EPA’s CPG for landscaping products; and for new construction, where conditions permit, the site shall be landscaped for low maintenance and water conservation with plants that are either native or well-adapted to the local growing conditions.

8. Plumbing – The Offeror must provide plumbing fixtures that conform to EPA WaterSense or fixtures with equivalent flush volumes/flow rates.

Version 3.0 - January 2020 Page 11 of 21

Typical Design Layouts

HSDN/TALON Room Configuration

Showers

Version 3.0 - January 2020 Page 12 of 21

Wall Partition Types

Version 3.0 - January 2020 Page 13 of 21

Schedules

Ceilings

TYPE DESCRIPTION

C1 TYPICAL OFFICE SPACES

Minimum ceiling height 8’-0”. 2’ X 2’ Acoustical Ceiling Tile (ACT) with tegular edges with a minimum 25% recycled content.

C2

PUBLIC ENTRY/SECURITY SCREENING/WAITING ROOM

Minimum ceiling height 12’-0”. 2’ x 2’ ACT with tegular edges with a minimum 25% recycled content; or painted exposed deck (spiral duct is required if the deck is exposed); or a combination of high-quality ceiling tile with GWB accents. The Government shall approve the proposed ceiling design.

C3

COMPUTER TRAINING/NATURALIZATION ROOM

Minimum ceiling height 10’-0”. 2’ X 2’ Acoustical Ceiling Tile (ACT) with tegular edges with a minimum 25% recycled content.

The ceiling may incorporate painted GWB accents at column lines or other areas to enhance the prominence of the room.

C4

COMPUTER ROOM & REMOTE WIRING CLOSET

Minimum ceiling height 8’-6”. Acoustical Ceiling Tile (ACT) with tegular edges with a minimum 25% recycled content. Space above the ceiling must be free from sprinkler mains, plumbing runs, building HVAC ductwork, condensate drains and HVAC equipment. The adjacent wall must also be free from adjoining plumbing or water pipelines. Restrooms, kitchens, or other similar space shall not be located directly over the LAN/Computer Room.

C5 BULK STORAGE/LOADING & RECEIVING AREA

Minimum ceiling height 8’-0”. Exposed or painted exposed deck.

C6 EMPLOYEE & PUBLIC RESTROOMS

Minimum ceiling height 8’-0”. Painted moisture resistant GWB or 2’ X 2’ GWB tiles.

C7

HSDN/TALON

Minimum ceiling height 8’-0”. 2’ X 2’ Acoustical Ceiling Tile (ACT) with tegular edges with a minimum 25% recycled content.

Ceiling system will be required to help this room achieve a STC-55 (ASTC-52) rating. Lessor to coordinate one acoustical test during construction (acoustical engineer to provide any necessary recommendations) and one acoustical test after construction to verify STC-55 (ASTC-52) to meet ASTM-E336-17A testing standards with typical field allowances.

Doors

D1

LOCKABLE OFFICE

Solid Core (SC) hardwood veneer door with commercial-grade mortise hardware (office function lockset) with replaceable core and 2" hollow metal (HM) frame with welded corners. Provide 18" sidelight assembly adjacent to door integral with HM door frame. See General notes #4.

D2

NON-LOCKABLE OFFICE

SC hardwood veneer door with commercial-grade mortise hardware (passage function) and 2" HM frame with welded corners.

Provide 18" sidelight assembly adjacent to door integral with HM door frame. See General Notes #4.

D3*

SECURE SPACES WITH SIDELIGHT ASSEMBLY

SC hardwood veneer door with commercial-grade mortise hardware (storeroom function lockset) with a high-security replaceable core, door closer, and 2" HM frame with welded corners. Provide ESS Access Control System in accordance with USCIS Facility Security Specific Requirements. Devices shall be connected to the ACS's central system. Components are to include contact/contactless card reader, door position switch, a request to exit device and electric strike. Provide 18" sidelight assembly adjacent to door integral with HM door frame. See General Notes #3. Automatic door opener may be required. Kick plate and door protection may be required for doors with high traffic and/or on a file cart path may be required.

D4*

SECURE SPACES WITHOUT SIDELIGHT ASSEMBLY

SC hardwood veneer door with commercial-grade mortise hardware (storeroom function lockset) with a high-security replaceable core, door closer, and 2" HM frame with welded corners. Provide ESS Access Control System in accordance with USCIS Facility Security Specific Requirements. Devices shall be connected to the ACS's central system. Components are to include contact/contactless card reader, door position switch, a request to exit device and electric strike. Kick plate and door protection may be required for doors with high traffic and/or on a file cart path may be required.

D5

WAITING ROOM & WEATHER VESTIBULE ENTRY

Glass double doors with pivot hardware and magnetic locks. Additional glass panels/sidelights may be required to ensure sightlines are maintained for guards for security. Automatic door opener required.

D6 INTERVIEW ROOM (2 doors to each room)

Version 3.0 - January 2020 Page 14 of 21

Back of house door: Solid Core (SC) hardwood veneer door with commercial-grade mortise hardware (office function lockset) with thumb latch on the CORRIDOR SIDE with replaceable core and 2" hollow metal (HM) frame with welded corners. Provide 18" sidelight assembly adjacent to door integral with HM door frame. See General notes #4.

Waiting Room side door: Aluminum storefront assembly glass door with storeroom function lockset.

D7

AUDIO VISUAL & CHAIR STORAGE

SC hardwood veneer door with commercial-grade mortise hardware (office function lockset) with a replaceable core, door closer, and 2” HM frame with welded corners.

D8 HSDN/TALON ROOM

Door and associated door frame to maintain a STC-55 (ASTC-52) rating for the entire room. Door and hardware to be commercial-grade mortise hardware (storeroom function lockset) with a high-security replaceable core, door closer, and all necessary gaskets to maintain the STC rating. Provide ESS Access Control System in accordance with USCIS Facility Security Specific Requirements. Devices shall be connected to the ACS's central system. Components are to include contact/contactless card reader, door position switch, request to exit device, electric strike, automatic door bottom and floor threshold (Pemko 412 PKM or equal). Lessor to coordinate one acoustical test during construction (acoustical engineer to provide any necessary recommendations) and one acoustical test after construction to verify STC-55 (ASTC-52) to meet ASTME336-17A testing standards with typical field allowances.

D9*

BULK STORAGE & MAILROOM

4’-0” x 7’-0” painted hollow metal door with commercial-grade mortise hardware (storeroom function lockset) with a high-security replaceable core, door closer, 2” HM frame with welded corners and kick plates (both sides) from just below the door handle to 3” AFF and the width of the door. Provide ESS Access Control System in accordance with USCIS Facility Security Specific Requirements. Devices shall be connected to the ACS's central system. Components are to include contact/contactless card reader, door position switch, a request to exit device, and electric strike.

D10

RESTROOM/SHOWER ROOM

SC hardwood veneer door with push/pull hardware, door closer and 2” HM frames with welded corners. Automatic door opener required.

D11

LACTATION ROOM

SC hardwood veneer door with commercial-grade mortise hardware (privacy function) with occupied indicator lockset, replaceable core and 2” HM frame with welded corners.

D12

LOCKABLE ROOM WITHOUT SIDELIGHT

Solid Core (SC) hardwood veneer door with commercial-grade mortise hardware (storeroom function lockset) with replaceable core and 2" hollow metal (HM) frame with welded corners.

* - Doors with ESS: If electric strike opens to non-secure space, install strike latch guard.

- All other doors that open into non-secure space: Install non-removable pins at each hinge.

Electrical - Power and Data

E1 DISTRICT & FIELD DIRECTOR OFFICES

Provide four duplex electrical receptacles, two duplex data (2D) drops and one cable television outlet (CATV).

E2 TYPICAL OFFICE AREAS

Provide four duplex electrical receptacles, and one duplex data (2D) drops.

E3

CONFERENCE ROOM

Provide a minimum of three duplex electrical receptacles (one on each side and back wall), one quadruplex receptacle on the front wall and one recessed floor outlet coordinated with the conference room table base and equipped with a removable cover or protective slide cover. Provide two duplex data (2D) drops on the front wall, one duplex data (2D) drop on the back wall and one duplex data (2D) drop terminated on the surface of the conference table through the recessed floor box. Provide CATV on the front wall in coordination with the AV design. Refer to the USCIS AV Standards document for conduit infrastructure and plywood backing layout within the wall for Government provided wall mounted LCD’s.

E4

OPEN AREA PLANNING/SYSTEMS FURNITURE

Provide one duplex data (2D) drop and one electrical connection per each system furniture unit (no power poles). There will be approximately 61 system furniture units. Include at least one duplex electrical receptacle and duplex data (2D) drop on open walls identified during design planning for network printers and fax machines.

E5

COPIER AREAS

Provide one dedicated duplex electrical receptacle and one duplex data (2D) drop per copier. Provide two duplex electrical outlets and one duplex data (2D) drop at counter height.

E6 GUARD/PIV ROOM/STORAGE/STAGING ROOM

Provide two duplex electrical receptacles and one duplex data (2D) drop.

Version 3.0 - January 2020 Page 15 of 21

E7 NATURALIZATION PREP ROOM

Provide four duplex electrical receptacles and a minimum of one duplex data (2D) drop.

E8

WAITING ROOM

Provide convenience duplex electrical receptacles as identified during the design planning. Provide additional duplex electrical receptacles, duplex data drops and CATV outlets for AV design at a ratio of one set per every 500 square feet. Refer to the USCIS AV Standards document for conduit infrastructure and plywood backing layout within the wall for Government provided wall mounted LCD’s. Provide one wall phone (1V) location at 54” AFF at each ISO entrance into the waiting room on the secure side of the door for overhead paging.

E9 Provide duplex electrical receptacles and duplex data (2D) drops at a ratio of one per 300 square feet (minimum of one each).

E10 Not Used.

E11 Not Used.

E12 HSDN/TALON ROOM

Provide three (3) duplex electrical receptacles, two (2) dedicated 20 amp circuits each with duplex NEMA 5-20R receptacles (one for the HSDN cabinet and one for the NSA approved shredder). Install one (1) CMP – plenum rated armored fiber cable in wall-mount enclosure at 18” below the finished ceiling directly above the HSDN rack and three (3) standard data drops. Refer to USCIS Structured Cable Plant Scope of Work for site specific requirements. Electrical receptacle and data drop locations shall maintain a STC-55 (ASTC-52) rating. Lessor to coordinate one acoustical test during construction (acoustical engineer to provide any necessary recommendations) and one acoustical test after construction to verify STC-55 (ASTC-52) to meet ASTM- E33617A testing standards with typical field allowances.

E13

AUDIO VISUAL & CHAIR STORAGE

Provide three duplex electrical receptacles and one duplex data (2D) drop. Provide one duplex electrical receptacle and one empty single-gang box mounted horizontally at 30” AFF with two conduit stubs AFC along with plywood backing in the wall for AV equipment enclosure. Refer to the USCIS AV Standards document for conduit infrastructure layout within the wall.

E14

TRAINING/NATURALIZATION ROOMS

Recessed Floor: Provide recessed floor outlets containing one duplex data (2D) drop and one duplex electrical receptacle which shall be flush with the finished floor and equipped with a removable cover or protective slide covers. Exact quantity will be determined during design.

Front Wall AV: Provide a minimum of one quadruplex electrical receptacle, one duplex data (2D) drop, and one CATV outlet.

Provide additional conduit and box infrastructure for AV equipment along with plywood backing for Government provided wall mounted projector screen or LCD monitor and speaker locations.

Ceiling: Provide one duplex electrical receptacle and one duplex data (2D) drop in ceiling tile approximately 14’-0” off the front wall for the Government provided projector, if applicable.

Back Wall: Provide one duplex electrical receptacle and one duplex data (2D) drop on the back wall.

Side Walls: Provide one duplex electrical receptacle and one duplex data (2D) drop on the side wall for instructor podium, if applicable. Provide duplex electrical receptacles with multiple circuits for computers and duplex data (2D) drops (minimum quantity (12) on side walls).

Refer to the USCIS AV Standards document for conduit infrastructure

E15

BREAKROOM

Provide three duplex electrical receptacles and one wall phone (1V) location at 54” AFF. Provide two (unless otherwise indicated during the design planning) dedicated duplex electrical receptacles for refrigerators and two dedicated duplex electrical receptacles for vending machines. Provide two dedicated electrical receptacles for microwave ovens above the counter.

Provide two additional duplex electrical receptacles above the counter (GFI as required by code). Provide one duplex electrical receptacle, one duplex data (2D) drop and one CATV drop on the wall at 12" BFC for AV Digital Signage. Refer to the USCIS AV Standards document for conduit infrastructure and plywood backing layout within the wall for Government provided wall mounted LCD’s.

E16 COMPUTER STORAGE AND STAGING ROOM

Provide four duplex electrical receptacles on two 20 amp electric circuits and six duplex data (2D) drops.

Version 3.0 - January 2020 Page 16 of 21

E17

COMPUTER LAN ROOM

Provide a recessed independent electrical panel in this room for all circuits (except lighting). The electrical panel must have 25% space capacity and a secondary ground connection to the TMGB within the room. Provide emergency power off button with a protective cover located adjacent to the door(s) that will shut down all power for electrical panels in this room. The installation of the grounding/bonding system shall follow the requirements in accordance with BICSI-J-STD-607-A and ANSI/TIA/EIA-606 standards for labeling along with the NEC (National Electrical Code). Bonding conductor shall originate for the Electrical Entrance Facility to the TMGB typically with 3/0 AWG due to length. Building steel may only be utilized as a secondary connection. A #6 AWG copper ground shall be utilized for the bonding equipment within this room for racks, ladder runway equipment, etc. Provide a minimum of eight (8) dedicated 30 amp 125/120 volt, NEMA L14-30R, 3P, 4W, grounding, locking receptacle with twist-lock outlets mounted in the ceiling tiles above equipment racks and cabinets. Provide one dedicated, L-5 twist-lock 125 volt 30 amp outlet (NEMA L5-30R) and one dedicated L-6 twist-lock 220 volt 30 amp outlet (NEMA L6-30R) and one dedicated 110 volt 20 amp outlet (NEMA 5-20R for security equipment requirements. Provide a minimum of six (6) dedicated duplex 110 volt 20 amp outlets (NEMA 5-20R) and a minimum of four (4) dedicated quadruplex 110 volt 20 amp outlets (NEMA 5-20R) receptacles on the wall behind the equipment racks and on side walls. Data/Voice – Provide one duplex data (2D) locations (near security system and back wall) and two wall phone (1V) locations at 54" AFF (front wall near door and back wall). Provide two (2) 4" conduits EMT raceways with pull strings to the location (Telephone Room, Electrical closet, etc.)

within the facility where the building demarcation resides (typical of existing facilities). USCIS will contract requirements and coordinate with service providers to pull required cable type in these raceways to extend voice and data circuits along with CATV services into the LAN/Computer Room. A 24" ladder runway shall be installed above two-post stand-alone equipment racks, enclosures and cabinets to provide cable management from side to side and front to back of the room. Provide a minimum of 4' clearance behind and 3' clearance in front of two-post stand-alone equipment racks. Provide a minimum 4' clearance behind and 3' clearance in front of the four-post equipment racks, enclosures, and cabinets. Provide Category 6 patch panels, 3U, 2U, 1U horizontal wire managers, 19" shelves, PDU's and 10" vertical wire management on 19" stand alone equipment racks, etc. to support Cat 6 cable duplex (2D) locations and single voice Cat 6 (1V) wall phone plates throughout floor space. The building lessor is responsible for providing two analog telephone lines (POTS) for the duration of the lease term. One is provided for the IDS reporting to the FPS MegaCenter. One is provided for the environmental alarm system within the LAN Room.

E18

MAILROOM

Provide dedicated electrical service for the X-Ray machine. Provide four duplex electrical receptacles. Provide three duplex data (2D) drops. Provide one wall phone (1V) location at 54” AFF. Some outlets may be required to be located at counter height. Depending on the final size and layout of this room, the exact quantity and location of electrical receptacles and data drops will be determined during design.

E19 LACTATION ROOM

Provide three duplex electrical receptacles and one at counter height. Provide one wall phone (1V) location at 54” AFF.

E20

REMOTE WIRING CLOSET

Provide an independent recessed electrical panel in this room for all circuits (except lighting). The electrical panel must have 25% space capacity and a secondary ground connection to the TMGB within the room. Provide emergency power off button with a protective cover located adjacent to the door(s) that will shut down all power for an electrical panel in this room. The installation of the grounding/bonding system shall follow the requirements in accordance with BICSI-J-STD-607-A and ANSI/TIA/EIA-606 standards for labeling along with the NEC (National Electrical Code). Bonding conductor for TR shall originate for the TMGB within the LAN/Computer Room typically with 3/0 AWG due to length. Building steel may only be utilized as a secondary connection. A #6 AWG copper ground shall be utilized for the bonding equipment within this room for racks, ladder runway equipment, etc. Provide a minimum of four (4) dedicated 30 amp 125/120 volt, NEMA L14-30R, 3P, 4W, grounding, locking receptacle with twist-lock outlets mounted in the ceiling tiles above equipment racks. Provide a minimum of four (4) dedicated duplex 110 volt 20 amp outlets (NEMA 5-20R) and a minimum of two (2) dedicated quadruplex 110 volt 20 amp outlets (NEMA 5-20R) receptacles on the wall behind the equipment racks and on side walls. The types and quantity of electrical receptacles may be updated after lease award and during the design phase due to changing technologies. Data/Voice – Provide one wall phone (1V) locations at 54" AFF. An 18" ladder runway shall be installed above two-post stand-alone equipment rack(s) to provide cable management from side to side and front to back of the room. Provide a minimum of 3' clearance behind and 3' clearance in front of two-post stand-alone equipment rack(s). Provide Category 6 patch panels, 3U, 2U, 1U horizontal wire managers, 19" shelf, PDU's and 10" vertical wire management on 19" stand-alone equipment rack(s,), etc. to Cat 6 cable duplex (2D) locations and single voice Cat 6 (1V) wall phone plates throughout floor space.

E21

SECURITY SCREENING/WEATHER VESTIBULE

Provide two dedicated duplex electrical receptacles and two duplex data (2D) drops per each Guard Desk location. Provide two duplex electrical receptacles and two duplex data (2D) drops per Reception Desk location. Provide one duplex electrical receptacle and one duplex data (2D) drop for each Info/Pass kiosk. Some outlets may be required to be located at counter height.

E22 EMPLOYEE & PUBLIC RESTROOMS

Provide a minimum of one GFI electrical outlet at counter height.

E23

BIOMETRIC STATIONS

Provide a minimum of one dedicated duplex electrical receptacle and one duplex data (2D) drop per biometric machine location.

Provide one convenience duplex electrical receptacle on the back wall.

Version 3.0 - January 2020 Page 17 of 21