This document is a Space Allocation Standards Summary for the USCIS Phoenix Field Office, detailing a medium/large model office space configuration. The facility encompasses 34,431 total square feet, with 14,610 square feet of primary space and 19,821 square feet of support space, designed to accommodate 109 employees at a 134 square foot per person utilization rate. The space includes 25 multi-purpose interview rooms, 21 standard interview rooms, and 4 video interview rooms, with an annual capacity of 16,222 N-400 interviews and 20,619 on-site interview capabilities.

The office layout features 17 120-square-foot offices, 1 100-square-foot office, 66 48-square-foot workstations, and various support spaces including a break room, file areas, teaming rooms, server room, lobby, waiting room, and a ceremony room. Parking provisions include 6 spaces included in the rent (4 government vehicles and 2 official visitor spaces), with 109 employee parking spaces and 91 visitor parking spaces commercially available within a quarter-mile. The document was approved by the USCIS Central Region and digitally signed on December 13, 2023, indicating it is a current space planning document for the Phoenix Field Office.

View the file

Other files

Show all 22

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Phoenix Field Office Space Allocation Standards Summary Medium/Large Model Office

14,610 Primary Space (62% | 9,058 square feet plus 38% | 5,552 square feet of circulation space)

19,821 Support Space (62% | 12,289 square feet plus 38% | 7,532 square feet of circulation space)

34,431 Total Square Footage

134 SF/Person Utilization Rate

4 Government Owned Vehicles

2 Official Visitors

6 Parking Spaces included in the RENT

109 Employee Parking (% utilize public transit)

91 Visitor Parking (% utilize public transit)

200 Parking Spaces Commercially Available within 1/4 mile (walking distances) not included in RENT

16,222 Annual N-400s Interviews (includes any conducted for other offices via Office to Office Video Interviews)

20,619 On Site Interview Capacity (FOD in person or via video interview conducted by remote offices)

21 Multi-Purpose Interview Rooms

4 Video Interview Rooms

3 Multi-Purpose Interview Rooms (Asylum)

- Multi-Purpose Interview Rooms (ASC - Dual Biometric Stations)

57,703 Total A-File Holdings (includes those for ICE and CBP)

109 Total Number of Employees

109 Total Number of Employees Reporting to Office Daily (includes workers on AWS and teleworking 2 days per week)

- Teleworkers (teleworking more than 2 days per week)

- Remote Workers

- 150 Square Foot Offices

25 Multi-Purpose Interview Rooms (including those for ASC and Asylum Circuit Riders)

17 120 Square Foot Offices

1 100 Square Foot Offices

- 64 Square Foot Workstations

66 48 Square Foot Workstations

4 48 Square Foot Interview PODS (for conducting office to office interviews on office to onsite video interview room)

- 36 Square Foot Teleworkstations (teleworkers)

- 24 Square Foot Teleworkstations (remote workers and others)

113 Total Number of Workspaces

Approving Official's Digital Signature:

Quantity Of Workspaces

Parking Requirements

The USCIS Central Region has reviewed and approves this Space Allocation Standards for the Phoenix Field Office which totals 34,431 usable square feet of space to accomodate 109 employees, 6 parking spaces under rent for 4 GOVs and 2 Official Visitors (other government vehicles). There will be 109 employee spaces and 91 visitor parking spaces that will be commercially available at the employee's and visitor's expense within 1/4 mile of the building entry. All other employees and visitors are anticipated to utilize public transit.

Region Concurrence

Space Requirement

Note: For all public functions to be on a single floor, the floor size must be a minimum of 14,395 square feet.

Interviewing Capacity

Staffing Data

File Capacity

USCIS FO SAS V1.3 7.20.23

SARAH M

KENDALL

Digitally signed by

SARAH M KENDALL

Date: 2023.12.13 12:16:08 -05'00'

Space Allocation Standards Medium/Large Model Office

Quantity

Required

Usable

Square Feet

Each

Total

Square

Footage

Without

Circulation

120 Square Foot Offices 17 120 2,040

100 Square Foot Offices 1 100 100

48 Square Foot Workstations 66 48 3,168

Reception Area 1 50 50

Copier Areas 5 50 250

Break Room / Employee Lounge - may be enclosed or semi open 1 415 415

Kitchenette/Galley (1 per floor where Break Room not located or excessive floor size) 1 64 64

File Area(s) - may be enclosed or open or combination 1 1,920 1,920

Interview PODS (for Office to Office Interviews) 4 48 192

Management (FOD) Conference Room VTC 1 275 275

Teaming Rooms (4-7 people | approximately 1 room per supervisory group) 8 120 960

Team Collaboration Room VTC 1 225 225

Bulk Storage 1 700 700

Computer Staging and Storage 1 150 150

HSDN Talon Room 1 120 120

Lactation Room - includes lavatory/sink 2 64 128

Mail Room and File Staging/Retirement 1 610 610

Employee Restrooms - one per floor - (1) toilet and (1) lavatory each 2 65 130

Employee Shower | Men - (2) shower stalls, (1) lavatory, (6) 2-tier lockers (12 compartments) 1 220 220

Employee Shower | Women - (2) shower stalls, (1) lavatory, (6) 2-tier lockers (12 compartments) 1 220 220

Remote Wiring Closet(s) 1 100 100

Server Room 1 350 350

Union Office 1 135 135

Lobby (includes space for (1) security screening lanes and (3) check-in lanes including queueing spa 1 900 900

Weather Vestibule 1 50 50

Public Restroom | Men - (1) toilets, (1) urinals and (1) lavatories 1 150 150

Public Restroom | Family - (1) toilets and (1) lavatories 1 75 75

Public Restroom | Women - (3) toilets and (1) lavatories 1 185 185

Waiting Room 1 1,395 1,395

Multi-Purpose Interview Rooms 25 150 3,750

Video Interview Rooms (small - 4 person capacity) 2 85 170

Video Interview Rooms (large - 6 person capacity) 2 100 200

Ceremony Room (non-fixed seating) 1 1,800 1,800

Chair, Table and A/V Storage (Naturalization Ceremony Room) 1 150 150

TOTAL SQUARE FOOTAGE REQUIRED (62%) 21,347

CIRCULATION AND LAYOUT FACTOR (38%) 13,084

TOTAL SQUARE FOOTAGE REQUIRED 34,431

P u b lic

F ac in g

Sp ac e s

M e e ti n g

Sp ac e s

SPACE DESCRIPTION

O p en o r

En cl o se d

En cl o se d S u p p o rt S p ac e s

O p e n

O ff ic e

Phoenix Field Office

P ri va te

O ff ic e s

USCIS FO SAS V1.3 7.20.23

Total Staff Program 0 District Office (4 positions accounted for under Field Office Management)

18 Field Office Management (total supervisory and non-supervisory staff)

50 Immigration Services (total supervisory and non-supervisory staff)

24 Immigration Services Support (total supervisory and non-supervisory staff)

9 FDNS (total supervisory and non-supervisory staff)

3 OIT (total supervisory and non-supervisory staff - including OIT contractors)

1 OSI (total supervisory and non-supervisory staff)

4 HQ Support (total supervisory and non-supervisory staff)

0 ASC (total supervisory and non-supervisory staff)

0 Contractors (total supervisory and non-supervisory staff excluding OIT contractors)

Phoenix Field Office Staffing Breakdown - For Regional Review Purposes Only (Do not distribute to GSA)!

Medium/Large Model Office

USCIS FO SAS V1.3 7.20.23

SF81 Cover Letter (Backup).pdf
USCIS Phoenix Field Office Requirements Pt 1.pdf
Binder1.pdf
GSA Standard Form 81 signed.pdf
PHO-FO-FY23A SF-81 Supporting Documentation (Backup).pdf
PHO-FO-FY23A SAS v4 Project Cost Estimate backup
USCIS PHO-FO-FY23A Special Requirements backup
Overview
Building Design
Branding
Lady Liberty
Exterior Signage
Interior Signage
Color Palettes
Building Hours of Operation
Test-Fit Layout
Field Office Director’s Area
Immigration Services
Immigration Services Support
Joint Use and Office Support Space
General Notes
Environmental Considerations
Typical Design Layouts
HSDN/TALON Room Configuration
Showers
Wall Partition Types
Schedules
Ceilings
Doors
Electrical - Power and Data
Flooring
HVAC - Mechanical
Lighting
Miscellaneous
Security
Walls

USCIS Overview - PHO FO 2023-07-18 backup

PHO-FO-FY23A SAS v3.2 CRO Signed.pdf

File details come from the government source that posted it. Updated .