ESBD_572949_1793401817671_SOL_EXH_F.10_SOW - B.pdf
PDF 8 MB Posted
- Attached to
- Building G Generator Replacement - HQ
- Solicitation number
- 405-27R0002844
- Issued by
- Texas
About this file
This Scope of Work document outlines the generator replacement project for Building G at the headquarters facility in Texas. The project involves the removal of the existing generator unit and installation of a new generator system to ensure continued reliable power supply for critical operations. The contractor must coordinate with facility management, obtain necessary permits, and execute the work in accordance with all applicable codes and regulations. Specific requirements include site preparation, demolition of the existing equipment, installation of the new generator with all necessary connections and testing, and final commissioning prior to project completion. The contractor is responsible for managing all debris removal and site restoration to original conditions.
Pricing shall be submitted as a fixed-price bid for the complete scope of work, including labor, materials, equipment, and all incidental costs necessary for successful project completion. The project funding is provided through the state's capital improvement budget allocation. Contractors must provide detailed pricing breakdowns, project schedules, and evidence of relevant experience with similar generator replacement projects. All work must comply with applicable National Electric Code standards and local Texas building codes. The contractor must maintain current licensing and insurance coverage throughout the contract term.
View the file
Other files
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Cover Sheet Index
G-001
TEXAS DEPARTMENT OF
PUBLIC SAFETY
HEADQUARTERS -
BUILDING G
GENERATOR
TEXAS DEPARTMENT OF PUBLIC SAFETY
5805 N LAMAR BLVD
AUSTIN, TX 78752
4222 85th St.
Lubbock, TX 79423 806.473.2200
Sheet Index
General
G-001 Cover Sheet and Index
Electrical
E-001 Electrical Symbols, Legends & Abbreviations
ES100 Electrical Site Plan
E-501 Electrical Riser Diagram
Civil CE101 Erosion Control Plan
CE501 Erosion Control Details
CX101 Erosion Conditions & Removal Layout
CC101 Construction Layout
CC501 Construction Details
CG101 Grading Plan
Xref ..\..\..\..\46158.25\03_DSGN\01_DWG\010_GEN\XGTB-46158.dwg
Parkhill.com
PROJECT NO.
CLIENT
# DATE DESCRIPTION
KEY PLAN
A
\4
.2
\0
D S
G N
\0
D
W G
\1 E
L E
C \G
-0
-4
.D W
G
/1
/2
:0 P
M jip in a
T e x a s
D e p a rt m e n t o f P u b li c S a fe ty B u il d in g
G G e n e ra to r
Texas Department of Public Safety 5805 N Lamar Boulevard Austin, Tx 78752
47366.26
- 07/17/2026 Issue for Proposal
Parkhill.com
PROJECT NO.
CLIENT
# DATE DESCRIPTION
KEY PLAN
Te xa s D ep ar tm en t o f P ub lic
S af et y
B ui ld in g G
G en er at or
Texas Department of Public Safety 5805 N Lamar Boulevard Austin, Tx 78752
47366.26
- 07/17/2026 Issue for Proposal
Parkhill.com
07/17/2026
THIS DOCUMENT IS RELEASED
ON DATE INDICATED FOR THE
PURPOSE OF INTERIM REVIEW
UNDER THE AUTHORITY OF
SHARON S. BICKFORD LICENSE
#77390. IT IS NOT TO BE USED
FOR REGULATORY APPROVAL,
CONSTRUCTION, BIDDING OR
PERMIT PURPOSES.
PARKHILL, SMITH & COOPER,
INC.
ELECTRICAL
Parkhill.comParkhill.comParkhill.comParkhill.comParkhill.com
07/29/2026
- 07/29/2026 Issue for Proposal
P R
O F
E
SS I ONA L ENG
I N E
E R
SHARON S. BICKFORD
L
I C E N S
E
D
77390
STATE OF TEXAS
P A
R K
H I L
L S
M
I TH & COOPER
, I N C
F
ELECTRICAL ABBREVIATIONS
1 SINGLE PHASE
3 THREE PHASE
A
AAP ALARM ANNUNCIATOR PANEL
AC ABOVE COUNTER
ALTERNATING CURRENT
ACP AUTOMATIC CONTROL PANEL
ADC AUTOMATIC DOOR CLOSER
AF AUDIO FREQUENCY
AFC AUTOMATIC FREQUENCY CONTROL
AH AMPHOUR
AIC AMPERE INTERRUPTING CAPACITY
ALM ALARM
AMP AMPERE
AMPL AMPLIFIER
ANN ANNUNCIATOR
ANT ANTENNA
APU AUXILIARY POWER UNIT
ARMC ARMORED CABLE
ASC AMPS SHORT CIRCUIT
ASWG AMERICAN STEEL WIRE GAUGE
ATS AUTOMATIC TRANSFER SWITCH
AUTO XFMR AUTO TRANSFORMER
AUX AUXILIARY
AV AUDIO VISUAL
B
BAS BUILDING AUTOMATION SYSTEM
BAT BATTERY
BB XFMR BUCK-BOOST TRANSFORMER
BHP BRAKE HORSEPOWER
BKBD BACKBOARD
BLST BALLAST
BP CANDLE POWER
C
C CONDUIT
CC CONTROL CONTRACTOR
CAP CAPACITOR
CB CIRCUIT BREAKER
CCTV CLOSED CIRCUIT TELEVISION
CG COMMON GROUND
CKT CIRCUIT
CLF CURRENT LIMITING FUSE
COAX COAXIAL CABLE
COMM COMMUNICATIONS
COORD COORDINATE
COV PL COVER PLATE
CP CONTROL PANEL
CPT CONTROL POWER TRANSFORMER
CR CONTROL RELAY
CRI COLOR RENDERING INDEX
CS CONTROL SWITCH
CT CURRENT TRANSFORMER
CTRL CONTROL
CTV CABLE TELEVISION
CU COEFFICIENT OF UTILIZATION
COPPER
CUR CURRENT
D dB DECIBEL
DC DIRECT CURRENT
DEMO DEMOLITION
DET DETAIL
DPDT DOUBLE POLE, DOUBLE THROW
DPST DOUBLE POLE, SINGLE THROW
DS DISCONNECT SWITCH
E
EA EACH
ELEC ELECTRIC
EMT ELECTRICAL METALLIC TUBING
ENT ELECTRICAL NONMETALLIC TUBING
ENCL ENCLOSURE
ESMT EASEMENT
F
FA FIRE ALARM
FAAP FIRE ALARM ANNUNCIATOR PANEL
FACP FIRE ALARM CONTROL PANEL
FC FOOTCANDLE
FIXT FIXTURE
FLA FULL LOAD AMPS
FLUOR FLUORESCENT
FLUOR FIXT FLUORESCENT FIXTURE
FLUOR LGHT FLUORESCENT LIGHT
FMC FLEXIBLE METALLIC CONDUIT
FREQ FREQUENCY
G
GEN GENERATOR
GFCI GROUND FAULT CIRCUIT INTERRUPTER
GND GROUND
H
HD HEAVY DUTY
HO HIGH OUTPUT
HP HORSEPOWER
HV HIGH VOLTAGE
I
IESNA ILLUMINATION ENGINEERING SOCIETY OF NORTH AMERICA
IMC INTERMEDIATE METAL CONDUIT
J
NOT USED
K kW KILOWATT kWH KILOWATT HOUR kV KILOVOLT kVA KILOVOLT AMP
L
LFMC LIQUIDTIGHT FLEXIBLE METALLIC CONDUIT
LFNC LIQUIDTIGHT FLEXIBLE NONMETALLIC CONDUIT
LM LUMEN
LPW LUMENS PER WATT
LV LOW VOLTAGE
M
MCA MAIN CIRCUIT AMPS
MCB MAIN CIRCUIT BREAKER
MCC MOTOR CONTROL CENTER
MLO MAIN LUGS ONLY
MS MOTOR STARTER
N
NAC NOTIFICATION APPLIANCE CIRCUIT
NC NORMALLY CLOSED
NEC NATIONAL ELECTRICAL CODE
NEMA NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION
NL NIGHT LIGHT
NO NORMALLY OPEN
O
NOT USED
P
PA POWER AMPLIFIER
PB PANELBOARD
PE PHOTOELECTRIC
PEC PHOTOELECTRIC CELL
PF POWER FACTOR
PVC POLY VINYL CHLORIDE
PWR POWER
Q
NOT USED
R
RECEPT RECEPTACLE
RGS RIGID GALVANIZED STEEL
RNC RIGID NONMETALLIC CONDUIT
S
SCH SCHEDULE
SE SERVICE ENTRANCE
SPDT SINGLE POLE, DOUBLE THROW
SPST SINGLE POLE, SINGLE THROW
SWBD SWITCHBOARD
T
TSP TWISTED SHIELDED PAIR
U
UPS UNINTERRUPTIBLE POWER SUPPLY
V
V VOLT(S)
VOLTAGE
VA VOLT AMPERE
VD VOLTAGE DROP
VFD VARIABLE FREQUENCY DRIVE
VHO VERY HIGH OUTPUT
W
WP WEATHERPROOF
WW WIREWAY
X
NOT USED
Y
NOT USED
Z
NOT USED
# DATE DESCRIPTION
KEY PLAN
CLIENT
PROJECT NO.
Parkhill.com
/1
/2
:1
:2
P
M
00000.00.00
07/17/2026
R v
Project Status
Address Address City, State
Client Name
E-001
Electrical Symbols, Legends & Abbreviations
P ro je c t
N a m e P ro je c t
D e s c ri p ti o n
S u b ti tl e
THIS DOCUMENT IS RELEASED
ON DATE INDICATED FOR THE
PURPOSE OF INTERIM REVIEW
UNDER THE AUTHORITY OF
SHARON S. BICKFORD LICENSE
#77390. IT IS NOT TO BE USED
FOR REGULATORY APPROVAL,
CONSTRUCTION, BIDDING OR
PERMIT PURPOSES.
PARKHILL, SMITH & COOPER,
INC.
ELECTRICAL
ELECTRICAL SYMBOLS - MISC.
WALL SWITCH, REFER TO LIGHTING CONTROL MATRIX SCHEDULE FOR ALL
CONTROL REQUIREMENTS.
125V, 20A, 2P, 3W. GROUNDING TYPE DUPLEX RECEPTACLE. "GFCI" DENOTES
GROUND FAULT INTERRUPTER, "WP" DENOTES WEATHERPROOF COVER, "AC"
DENOTES ABOVE COUNTER MOUNTING, "USB" DENOTES COMBINATION USB
DEVICE.
JUNCTION BOX.
MOTOR.
SURFACE MOUNTED SINGLE SECTION PANELBOARD. LABEL INDICATES PANEL
NAME.
RECESSED MOUNTED SINGLE SECTION PANELBOARD. LABEL INDICATES PANEL
NAME REFER TO PANEL SCHEDULE AND RISER DIAGRAM FOR ADDITIONAL
INFORMATION.
SURFACE MOUNTED DOUBLE SECTION PANELBOARD. LABEL INDICATES PANEL
NAME. REFER TO PANEL SCHEDULE AND RISER DIAGRAM FOR ADDITIONAL
INFORMATION.
RECESSED MOUNTED DOUBLE SECTION PANELBOARD. LABEL INDICATES PANEL
NAME. REFER TO PANEL SCHEDULE AND RISER DIAGRAM FOR ADDITIONAL
INFORMATION.
EXISTING SURFACE MOUNTED SINGLE SECTION PANELBOARD. LABEL INDICATES
PANEL NAME. REFER TO PANEL SCHEDULE AND RISER DIAGRAM FOR ADDITIONAL
INFORMATION.
EXISTING RECESSED MOUNTED SINGLE SECTION PANELBOARD. LABEL INDICATES
PANEL NAME. REFER TO PANEL SCHEDULE AND RISER DIAGRAM FOR ADDITIONAL
INFORMATION.
EXISTING SURFACE MOUNTED DOUBLE SECTION PANELBOARD. LABEL INDICATES
PANEL NAME. REFER TO PANEL SCHEDULE AND RISER DIAGRAM FOR ADDITIONAL
INFORMATION.
EXISTING RECESSED MOUNTED DOUBLE SECTION PANELBOARD. LABEL INDICATES
PANEL NAME. REFER TO PANEL SCHEDULE AND RISER DIAGRAM FOR ADDITIONAL
INFORMATION.
SURFACE MOUNTED DISTRIBUTION PANELBOARD. LABEL INDICATES PANEL NAME.
REFER TO PANEL SCHEDULE AND RISER DIAGRAM FOR ADDITIONAL INFORMATION.
CONDUCTORS IN CONDUIT. MINIMUM NUMBER IS (2) #12 AWG + #12 GND. PROVIDE
NUMBER OF CONDUCTORS AS REQUIRED FOR SWITCHING INDICATED AND
CONTINUING CIRCUITS.
HOMERUN TO PANELBOARD. REFER TO SPECIFICATIONS FOR LIMITING NUMBER OF
CONDUCTORS PER HOMERUN.
DISCONNECT. AMPERAGE, POLES, AND FUSING AS NOTED.
STARTER/DISCONNECT. AMPERAGE, POLES, AND FUSING AS NOTED.
SURFACE MOUNTED RACEWAY.
POWER POLE.
WEATHERHEAD.
PULL BOX.
ELECTRICAL SYMBOLS - SITE
PAD MOUNTED DRY-TYPE TRANSFORMER. LABEL INDICATES TRANSFORMER NAME.
REFER TO TRANSFORMER SCHEDULE AND RISER DIAGRAM FOR ADDITIONAL
INFORMATION.
PAD MOUNTED UTILITY TRANSFORMER. LABEL INDICATES TRANSFORMER NAME.
REFER TO TRANSFORMER SCHEDULE AND RISER DIAGRAM FOR ADDITIONAL
INFORMATION.
PAD MOUNTED SINGLE SECTION SWITCHBOARD. LABEL INDICATES PANEL NAME.
REFER TO PANEL SCHEDULE AND RISER DIAGRAM FOR ADDITIONAL INFORMATION.
PAD MOUNTED DOUBLE SECTION SWITCHBOARD. LABEL INDICATES PANEL NAME.
REFER TO PANEL SCHEDULE AND RISER DIAGRAM FOR ADDITIONAL INFORMATION.
PAD MOUNTED TRIPLE SECTION SWITCHBOARD. LABEL INDICATES PANEL NAME.
REFER TO PANEL SCHEDULE AND RISER DIAGRAM FOR ADDITIONAL INFORMATION.
MANHOLE.
UNDERGROUND ELECTRICAL.
EXISTING UNDERGROUND ELECTRICAL.
OVERHEAD ELECTRICAL.
EXISTING OVERHEAD ELECTRICAL.
UNDERGROUND COMMUNICATIONS CABLE.
EXISTING UNDERGROUND COMMUNICATIONS CABLE.
Parkhill.com
PROJECT NO.
CLIENT
# DATE DESCRIPTION
KEY PLAN
T e x a s
D e p a rt m e n t o f P u b li c S a fe ty B u il d in g
G G e n e ra to r
Texas Department of Public Safety 5805 N Lamar Boulevard Austin, Tx 78752
47366.26
- 07/17/2026 Issue for Proposal
Parkhill.com
PROJECT NO.
CLIENT
# DATE DESCRIPTION
KEY PLAN
Te xa s D ep ar tm en t o f P ub lic
S af et y
B ui ld in g G
G en er at or
Texas Department of Public Safety 5805 N Lamar Boulevard Austin, Tx 78752
47366.26
- 07/17/2026 Issue for Proposal
Parkhill.com
07/17/2026
THIS DOCUMENT IS RELEASED
ON DATE INDICATED FOR THE
PURPOSE OF INTERIM REVIEW
UNDER THE AUTHORITY OF
SHARON S. BICKFORD LICENSE
#77390. IT IS NOT TO BE USED
FOR REGULATORY APPROVAL,
CONSTRUCTION, BIDDING OR
PERMIT PURPOSES.
PARKHILL, SMITH & COOPER,
INC.
ELECTRICAL
Parkhill.comParkhill.comParkhill.comParkhill.comParkhill.com
07/29/2026
- 07/29/2026 Issue for Proposal
P R
O F
E
SS I ONA L ENG
I N E
E R
SHARON S. BICKFORD
L
I C E N S
E
D
77390
STATE OF TEXAS
P A
R K
H I L
L S
M
I TH & COOPER
, I N C
F
EE
E E E
E
E
E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
G G
G G
G G
G G
G
G
G
G
G
G
G
G
G
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S
W W
W W
W W
W W
W W
W W
W W
W W
W W
W W
W W
W W
W W
W W
W
EE
EE
E E
NORTH
0A1 ELECTRICAL SITE PLAN - BUILDING G
1" = 10' 10' 20'
AS INDICATED BY: 00
KEY NOTES
1. LOCATION OF EXISTING UTILITY TRANSFORMER.
2. LOCATION OF ELECTRICAL ROOM.
3. APPROXIMATE LOCATION OF EXISTING GENERATOR.
4. LOCATION OF EXISTING UPS AND OTHER ELECTRICAL EQUIPMENT.
5. PROPOSED LOCATION OF NEW 1000KW GENERATOR.
6. REFER TO CIVIL DRAWINGS FOR NEW PAD.
7. DISCONNECT AND REMOVE EXISTING GENERATOR AND ALL
AUXILLIARY EQUIPMENT (BATTERY CHARGER, ETC.). PATCH/REPAIR
WALL AND ROOF OPENINGS WHERE EXHAUST DUCT AND PIPING ARE
REMOVED. REFER TO NOTES ON THIS SHEET.
8. NEW SERVICE-RATED ATS.
9. NEW DOCKING STATION. PROVIDE NEMA 3R DUAL-PURPOSE DOCKING
STATION PER SPECIFICATIONS.
10. APPROXIMATE LOCATION OF LOBBY, COORDINATE WITH OWNER ON
REPLACEMENT OF REMOTE ANNUNCIATOR. PATCH EXISTING WALLS
AS NECESSARY WHERE ANNUNCIATOR IS REPLACED.
11. PROVIDE NEW C/T CAN AND DISCONNECT C/T IN EXISTING MSB IN
ELECTRICAL ROOM. REFER TO RISER DIAGRAM FOR ADDITIONAL
DETAILS.
12. PROVIDE MAN-HOLE AND INTERCEPT EXISTING UNDERGROUND
FEEDER TO MSB TO INSTALL NEW FEEDER TO ATS. UTILIZE 3M RESIN
SPLICE KITS TO ENSURE WEATHERTIGHT INSTALLATION OF
CONDUCTORS.
13. REUSE AND EXTEND EXISTING CIRCUITS FOR GENERATOR AUXILIARY
EQUIPMENT FROM EXISTING GENERATOR ROOM OUT TO NEW
GENERATOR. ROUTE CONDUITS FROM BUILDING, ACROSS EQUIPMENT
SLAB TO GENERATOR. COMBINE CONDUITS IN ONE LOCATION TO
MINIMIZE TRIPPING HAZARD. PROVIDE #12 AWG WIRE IN 1" CONDUIT
FOR 120V CIRCUITS (AUXILIARY OUTLET, CONTROL PANEL, BATTERY
CHARGER, LIGHT, ETC.) AND #10 AWG WIRE IN 1" CONDUIT FOR 208V
CIRCUIT (HEATER).
GENERAL NOTES
A. CONTRACTOR SHALL VERIFY LOCATION OF ALL UNDERGROUND
UTILITIES PRIOR TO ANY EARTH WORK.
B. AS PART OF THE REQUIREMENTS OF THE CONTRACT, THE
ELECTRICAL CONTRACTOR SHALL VISIT THE SITE AND FAMILIARIZE
HIMSELF WITH THE SCOPE AND MAGNITUDE OF DEMOLITION WORK.
C. OWNER HAS FIRST RIGHT OF REFUSAL ON ALL EXISTING EQUIPMENT
TO BE DEMOLISHED AS PART OF THIS PROJECT (e.g. ATS &
GENERATOR). BEFORE DEMOLISHING, CONFIRM WHICH EQUIPMENT
WILL BE SALAVAGED BY THE OWNER. CONTRACTOR SHALL RELOCATE
SALVAGED EQUIPMENT TO APPROVED LOCATION ON THE DPS MAIN
HQ CAMPUS.
D. REFER TO CIVIL DRAWINGS FOR SCOPE OF SITE WORK, INCLUDING
REMOVAL OF CONCRETE, NEW GENERATOR PAD, NEW ENCLOSURE,
SIGNAGE, ETC.
E. PROVIDE TEMPORARY GENERATOR AND CONNECTIONS AS REQUIRED
TO MAINTAIN POWER TO EMERGENCY LOADS IN THE BUILDING
DURING CONSTRUCTION. OUTAGES SHALL BE PLANNED WITH OWNER
48 HOURS PRIOR.
F. IF NEW CONDUIT MUST BE ROUTED BETWEEN ELECTRICAL
EQUIPMENT, ROUTED PAVED PARKING AREA BY SAWCUTTING AND
REPAIRING, INSTEAD OF TRENCHING IN GRASS WHERE UTILITIES ARE
LOCATED. REFER TO CIVIL DRAWINGS FOR FURTHER INFORMATION.
ES100
Electrical Site Plan
Parkhill.com
PROJECT NO.
CLIENT
# DATE DESCRIPTION
KEY PLAN
A:
\2
6\
6.
\0 3_
D
SG
N \0
1_ D
W G
\1
_E
LE
C \E
-1
_4
.D
W G
, 7 /2
9/
:3
PM
, j ip in a
Te xa s D ep ar tm en t o f P ub lic
S af et y
B ui ld in g G
G en er at or
Texas Department of Public Safety 5805 N Lamar Boulevard Austin, Tx 78752
47366.26
- 07/29/2026 Issue for Proposal
12 8
GENERAL ARCHITECTURAL DEMOLITION NOTES
A. WALL OPENING: REMOVE LOOSE, DAMAGED, OR DETERIORATED
MATERIALS AROUND THE EXISTING WALL OPENING AS REQUIRED TO
PROVIDE A SOUND SUBSTRATE FOR INFILL. SAWCUT AND TOOTH
EXISTING MASONRY AS REQUIRED TO FACILITATE INTERLOCKING OF
NEW MASONRY WITH EXISTING CONSTRUCTION. PROTECT ADJACENT
CONSTRUCTION TO REMAIN.
B. CEILING/ROOF OPENING: REMOVE LOOSE, DAMAGED, OR
DETERIORATED MATERIALS AROUND THE EXISTING CEILING/ROOF
OPENING AS REQUIRED TO PROVIDE A SOUND SUBSTRATE FOR
INFILL. PROTECT ADJACENT CONSTRUCTION TO REMAIN.
GENERAL ARCHITECTURAL NEW CONSTRUCTION NOTES
A. WALL INFILL: INFILL EXISTING WALL OPENING WITH CONSTRUCTION
MATCHING THE ADJACENT EXISTING WALL ASSEMBLY, INCLUDING
MASONRY VENEER, AIR/WATER-RESISTIVE BARRIER, FLASHING,
INSULATION, SHEATHING, FRAMING, AND INTERIOR FINISH, AS
APPLICABLE. ALIGN NEW CONSTRUCTION WITH ADJACENT EXISTING
SURFACES. MATCH EXISTING MASONRY IN MATERIAL, SIZE, COLOR,
TEXTURE, COURSING, BOND PATTERN, PROFILE, AND MORTAR COLOR
AND TOOLING.
B. CEILING/ROOF INFILL: INFILL EXISTING CEILING/ROOF OPENING WITH
CONSTRUCTION MATCHING THE ADJACENT EXISTING ROOF
ASSEMBLY, INCLUDING ROOFING, AIR/WATER-RESISTIVE BARRIER,
FLASHING, INSULATION, DECK/SHEATHING, FRAMING, AND INTERIOR
CEILING FINISH, AS APPLICABLE. ALIGN NEW CONSTRUCTION WITH
ADJACENT EXISTING SURFACES. MATCH EXISTING ROOFING AND
INTERIOR FINISHES IN MATERIAL, SIZE, COLOR, TEXTURE, AND
PROFILE TO PROVIDE A SEAMLESS REPAIR.
Parkhill.comParkhill.comParkhill.comParkhill.com
07/29/2026
P R
O F
E
SS I ONA L ENG
I N E
E R
SHARON S. BICKFORD
L
I C E N S
E
D
77390
STATE OF TEXAS
P A
R K
H I L
L S
M
I TH & COOPER
, I N C
F http://www.parkhill.com/
AS INDICATED BY: #
KEYED NOTES
1. EXISTING UTILITY TRANSFORMER.
2. EXISTING GENERATOR LOCATED INSIDE BUILDING TO BE
REMOVED.
3. WHERE EXISTING ELECTRICAL EQUIPMENT IS REMOVED,
INTERCEPT AND UTILIZE AS MUCH OF EXISTING CONDUIT AND
CONDUCTORS AS POSSIBLE TO RECONNECT EXISTING LOADS.
LOCATE JUNCTION BOXES HIGH ON WALLS OR CEILINGS SO
THAT WALLS ARE LEFT AS CLEAR AS POSSIBLE.
PAD MOUNTED
UTILITY SERVICE
TRANSFORMER
EXISTING
EXISTING
DISTRIBUTION
Panel "MSB"
E N
ELEC ROOM
M
EXISTING
Panel "H1A"
EXISTING
DRY-TYPE
TRANSFORMER
"DTT-T1"
EXISTING
Panel "L1A"
EXISTING 750KW
GENERATOR
GENERATOR ROOMEXTERIOR
L
E N
L
E N
L
EXISTING
Panel "EH"
EXISTING
DISTRIBUTION
Panel "MSB"
UPS CH2
ATS #1 ATS #2 ATS #3
3 3 3
AS INDICATED BY: #
KEYED NOTES
1. NEW 1000 KW GENERATOR LOCATED OUTSIDE OF BUILDING.
REFER TO SITE PLAN.
2. (4) SETS OF (4) 600 KCMIL + 4/0 GND EACH IN 4" CONDUIT.
3. PROVIDE EQUIPMENT GROUNDING AS REQUIRED BY NFPA AND
SPECIFICATIONS.
4. DISCONNECT EXISTING C/T's IN MSB.
5. INTERCEPT EXISTING FEEDER TO INSTALL ATS.
6. RECONNECT EXISTING CH2.
PAD MOUNTED
UTILITY SERVICE
TRANSFORMER
EXISTING
EXISTING
SWITCHBOARD "MSB"
480/277V, 3Ø, 4W
1600 A MCB
ELEC ROOM
M
EXISTING
Panel "H1A"
EXISTING
DRY-TYPE
TRANSFORMER
"DTT-T1"
EXISTING
Panel "L1A"
NEW 1000KW
GENERATOR
EXTERIOR
NEW
DUAL-PURPOSE
DOCKING
STATIONE N
EXISTING
Panel "EH"
NEW 1600A
SVC-RATED
ATS
2 6
L
C/T
(3)-3/4" X 10' COPPER
CLAD DRIVEN
GROUND
RODS
METAL UNDERGROUND
WATER PIPE. BONDS
WITHIN
5' OF ENTRANCE INTO
BUILDING (IF AVAILABLE)
CONCRETE-ENCASED
GROUNDING ELECTRODE IN
ACCORDANCE WITH N.E.C
250.52(3)
#3/0 CU
CONDUCTOR IN
3/4"
RMC
#3/0
CU
#3/0
CU
BUILDING
STRUCTURAL
STEEL
NEUTRAL
BUS
BONDING
JUMPER #3/0
CU
MAIN SERVICE
SECTION IN
"MSB"
EQUIPMENT
GROUND
BUS
#4 AWG MINIMUM BARE
COPPER CONDUCTOR IN
CONCRETE 20' LONG
MIN.
MINIMUM 2" CONCRETE
ENCASEMENT
NOTE: BOND ALL GROUNDING
ELECTRODES IN ACCORDANCE WITH
N.E.C. ARTICLE 250 TO FORM A COMPLETE
GROUNDING ELECTRODE SYSTEM
# DATE DESCRIPTION
KEY PLAN
CLIENT
PROJECT NO.
Parkhill.com
/1
/2
:1
:2
P
M
00000.00.00
07/17/2026
R v
Project Status
Address Address City, State
Client Name
E-501
Electrical Riser Diagram
P ro je c t
N a m e P ro je c t
D e s c ri p ti o n
S u b ti tl e
THIS DOCUMENT IS RELEASED
ON DATE INDICATED FOR THE
PURPOSE OF INTERIM REVIEW
UNDER THE AUTHORITY OF
SHARON S. BICKFORD LICENSE
#77390. IT IS NOT TO BE USED
FOR REGULATORY APPROVAL,
CONSTRUCTION, BIDDING OR
PERMIT PURPOSES.
PARKHILL, SMITH & COOPER,
INC.
ELECTRICAL
NTS1 ELECTRICAL RISER DIAGRAM - DEMOLITION
NTS2
ELECTRICAL RISER DIAGRAM - NEW WORK
1/8" = 1'-0"3 GROUNDING DETAIL
Parkhill.com
PROJECT NO.
CLIENT
# DATE DESCRIPTION
KEY PLAN
T e x a s
D e p a rt m e n t o f P u b li c S a fe ty B u il d in g
G G e n e ra to r
Texas Department of Public Safety 5805 N Lamar Boulevard Austin, Tx 78752
47366.26
- 07/17/2026 Issue for Proposal
Parkhill.com
PROJECT NO.
CLIENT
# DATE DESCRIPTION
KEY PLAN
Te xa s D ep ar tm en t o f P ub lic
S af et y
B ui ld in g G
G en er at or
Texas Department of Public Safety 5805 N Lamar Boulevard Austin, Tx 78752
47366.26
- 07/17/2026 Issue for Proposal
Parkhill.com
07/17/2026
THIS DOCUMENT IS RELEASED
ON DATE INDICATED FOR THE
PURPOSE OF INTERIM REVIEW
UNDER THE AUTHORITY OF
SHARON S. BICKFORD LICENSE
#77390. IT IS NOT TO BE USED
FOR REGULATORY APPROVAL,
CONSTRUCTION, BIDDING OR
PERMIT PURPOSES.
PARKHILL, SMITH & COOPER,
INC.
ELECTRICAL
Parkhill.comParkhill.comParkhill.comParkhill.comParkhill.com
07/29/2026
- 07/29/2026 Issue for Proposal
P R
O F
E
SS I ONA L ENG
I N E
E R
SHARON S. BICKFORD
L
I C E N S
E
D
77390
STATE OF TEXAS
P A
R K
H I L
L S
M
I TH & COOPER
, I N C
F
E
EE
E
E E
E
E
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
SF
SF
SF
SF
SF
SF
LIMIT OF DISTURBANCE
STAGING AREA
SILT FENCE
CONCRETE WASHOUT
LIMIT OF DISTURBANCE
EROSION CONTROL LOG
Parkhill.com
PROJECT NO.
CLIENT
# DATE DESCRIPTION
KEY PLAN
A:
\2
6\
6.
\0 3_
D
SG
N \0
1_ D
W G
\0
_C
IV
IL
\0
3_
SH
EE
TS
\C E1
-4
.D W
G , 7
/2 9/
:5
PM
, c ha ds al l
Te xa s D ep ar tm en t o f P ub lic
S af et y
B ui ld in g G
G en er at or
Texas Department of Public Safety 5805 N Lamar Boulevard Austin, Tx 78752
47366.26
- 07/29/2026 Issue for Proposal
PRO
FESS I ONA L ENG I N
EERL
I C E N S E
D
STATE OF TEXAS
CASEY A. HADSALL
139380
PA
R
K H
I L L
S
M I TH & COOPER , I NC
. F
- 5
7/29/2026
CE101
Erosion Control Plan
EXISTING UTILITIES
CONTRACTOR MUST VERIFY LOCATION OF ALL OVERHEAD AND
UNDERGROUND UTILITIES PRIOR TO CONSTRUCTION. CONTRACTOR
SHALL COORDINATE WITH CITY OFFICIALS AND UTILITY COMPANIES
IN LOCATING UTILITIES. CONTRACTOR SHALL BE HELD RESPONSIBLE
FOR LOSSES DUE TO DAMAGE TO UTILITIES. LOCATION FOR ALL
UTILITIES SHOWN ON PLANS ARE APPROXIMATE. CONTRACTOR
SHALL CALL TEXAS 811, 1-800-344-8377.
N
0 10' 20'
CONTROL POINT #28
SET 5/8"
CONTROL POINT #26
SET 5/8"
N - 10092237.08 E - 3120097.49
ELEV. - 672.60
N - 10092262.50 E - 3120195.48
ELEV. - 670.68
BENCHMARK #31
BM ON TRANSFORMER PAD
N - 10092294.07 E - 3119994.93
ELEV. - 676.23
CONTROL POINT #29
SET 5/8"
N - 10092291.23 E - 3120138.99
ELEV. - 672.11
EROSION CONTROL LEGEND
PROPOSED 1' CONTOUR
PROPOSED 5' CONTOUR
LIMIT OF DISTURBANCE
SILT FENCE
EROSION CONTROL LOG
CONCRETE WASHOUT
SF SF SF
1. THE CONTRACTOR IS REQUIRED TO INSPECT THE CONTROLS AND
FENCES AT WEEKLY INTERVALS AND AFTER SIGNIFICANT RAINFALL
EVENTS TO ENSURE THAT THEY ARE FUNCTIONING PROPERLY. THE
CONTRACTOR IS RESPONSIBLE FOR MAINTENANCE OF CONTROLS AND
FENCES AND SHALL IMMEDIATELY MAKE ANY NECESSARY REPAIRS TO
DAMAGED AREAS. SILT ACCUMULATION AT CONTROLS MUST BE
REMOVED WHEN THE DEPTH REACHES SIX (6) INCHES.
2. ANY ON-SITE SPOILS DISPOSAL SHALL BE REMOVED PRIOR TO
ACCEPTANCE UNLESS SPECIFICALLY SHOWN ON THE PLANS. THE
DEPTH OF SPOIL SHALL NOT EXCEED 10 FEET IN ANY AREA.
3. PRIOR TO COMMENCEMENT OF CONSTRUCTION, SWPPP/EROSION
CONTROLS MUST BE PLACED ON SITE.
EROSION CONTROL NOTES
SURVEY LEGEND
EXISTING 1' CONTOUR
EXISTING 5' CONTOUR
SANITARY SEWER LINE
WATER LINE
UNDERGROUND ELECTRIC
GAS LINE
ELECTRICAL MANHOLE
ELECTRICAL BOX ABOVE GROUND
ELECTRICAL METER
GAS METER
IRRIGATION VALVE
TRANSFORMER
WATER VALVE
LIGHT POLE
SANITARY SEWER CLEANOUT
BOLLARD
UE UE UE
G G G
S S S
W W W
TOTAL DISTURBED
AREA = 0.07 ACRES
Parkhill.com
PROJECT NO.
CLIENT
# DATE DESCRIPTION
KEY PLAN
A:
\2
6\
6.
\0 3_
D
SG
N \0
1_ D
W G
\0
_C
IV
IL
\0
3_
SH
EE
TS
\C E5
-4
.D W
G , 7
/2 9/
:5
PM
, c ha ds al l
Te xa s D ep ar tm en t o f P ub lic
S af et y
B ui ld in g G
G en er at or
Texas Department of Public Safety 5805 N Lamar Boulevard Austin, Tx 78752
47366.26
- 07/29/2026 Issue for Proposal
PRO
FESS I ONA L ENG I N
EERL
I C E N S E
D
STATE OF TEXAS
CASEY A. HADSALL
139380
PA
R
K H
I L L
S
M I TH & COOPER , I NC
. F
- 5
7/29/2026
CE501
Erosion Control Details
B5 CONCRETE WASHOUT
NOT TO SCALE
10' MIN.
' M
IN
STAKE
(TYP)
STRAW BALE
(TYP)
10 MIL PLASTIC LINING
PLAN
TYPE "ABOVE GRADE" WITH STRAW
BALES
10 MIL PLASTIC LINING
BINDING WIRENATIVE MATERIAL
(OPTIONAL)
WOOD OR
METAL STAKES
(2 PER BALE)
STAPLES
(2 PER BALE)
1\8" DIA.
STEEL WIRE
2"
4"
STAPLE DETAIL
SECTION A-A
AA
CONCRETE WASHOUT SIGN DETAIL
(OR EQUIVALENT)
NOTES:
A. ACTUAL LAYOUT DETERMINED IN FIELD.
B. THE CONCRETE WASHOUT SIGN SHALL BE INSTALLED
WITHIN 30 FT. OF THE TEMPORARY CONCRETE
WASHOUT FACILITY.
CONCRETE
WASHOUT
3' 3'
PLYWOOD
48" X 24"
PAINTED WHITEBLACK LETTERS
6" HEIGHT
0.5" LAG
SCREWS
WOOD POST
3" X 3" X 8'
A5 SILT FENCE
1" = 1'-0" EC_SILT_FENC.dwg
GENERAL NOTES:
1. STEEL POSTS WHICH SUPPORT THE SILT FENCE SHALL BE INSTALLED
ON A SLIGHT ANGLE TOWARD THE ANTICIPATED RUNOFF SOURCE.
POST MUST BE EMBEDDED A MINIMUM OF ONE FOOT.
2. THE TOE OF THE SILT FENCE SHALL BE TRENCHED IN WITH A SPADE
OR MECHANICAL TRENCHER SO THAT THE DOWNSLOPE FACE OF THE
TRENCH IS FLAT AND PERPENDICULAR TO THE LINE OF FLOW.
WHERE FENCE CANNOT BE TRENCHED IN, ( e.g. PAVEMENT ), WEIGHT
FABRIC FLAP WITH ROCK ON UPHILL SIDE TO PREVENT FLOW FROM
SEEPING UNDER FENCE.
3. THE TRENCH MUST BE A MINIMUM OF 6 INCHES DEEP AND 6 INCHES
WIDE TO ALLOW FOR THE SILT FENCE FABRIC TO BE LAID IN THE
GROUND AND BACKFILLED WITH COMPACTED MATERIAL.
4. SILT FENCE SHOULD BE SECURELY FASTENED TO EACH STEEL
SUPPORT POST OR WOVEN WIRE, WHICH IS IN TURN ATTACHED TO
THE STEEL FENCE POST. THERE SHALL BE A 3' OVERLAP, SECURELY
FASTENED WHERE END OF FABRIC MEET.
5. INSPECTION SHALL BE MADE WEEKLY AND AFTER EACH RAINFALL.
REPAIR OR REPLACEMENT SHALL BE MADE PROMPTLY AS NEEDED.
6. SILT FENCE SHALL BE REMOVED WHEN THE SITE IS COMPLETELY
STABILIZED SO AS NOT TO BLOCK OR IMPEDE STORM FLOW OR
DRAINAGE.
7. ACCUMULATED SILT SHALL BE REMOVED WHEN IT REACHES A DEPTH
OF HALF THE HEIGHT OF THE FENCE. THE SILT SHALL BE
DISPOSED OF AT AN APPROVED SITE AND IN SUCH A MANNER AS
TO NOT CONTRIBUTE TO ADDITIONAL SILTATION.
SILT FENCE POST,
MAX 6' SPACING,
MIN EMBEDMENT = 1'
WIRE MESH BACKING SUPPORT
4" x 4" - 1.4 W x 1.4 W MINIMUM
ALLOWABLE, TYP CHAIN LINK
FABRIC IS ACCEPTABLE
FABRIC TOE-IN
TRENCH
SILT FENCE
( MIN 24" HT
ABOVE EXIST
GROUND )
COMPACTED
EARTH OR
BACKFILL
FLOW
6"
MIN
6"
MIN
EE
E
E E
E
E
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G G
G G
G G
G G
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
REMOVE 37 LF ~ EXISTING
STEEL FENCE
Parkhill.com
PROJECT NO.
CLIENT
# DATE DESCRIPTION
KEY PLAN
A:
\2
6\
6.
\0 3_
D
SG
N \0
1_ D
W G
\0
_C
IV
IL
\0
3_
SH
EE
TS
\C X1
-4
.D W
G , 7
/2 9/
:5
PM
, c ha ds al l
Te xa s D ep ar tm en t o f P ub lic
S af et y
B ui ld in g G
G en er at or
Texas Department of Public Safety 5805 N Lamar Boulevard Austin, Tx 78752
47366.26
- 07/29/2026 Issue for Proposal
PRO
FESS I ONA L ENG I N
EERL
I C E N S E
D
STATE OF TEXAS
CASEY A. HADSALL
139380
PA
R
K H
I L L
S
M I TH & COOPER , I NC
. F
- 5
7/29/2026
CX101
Existing Conditions & Removal Layout
EXISTING UTILITIES
CONTRACTOR MUST VERIFY LOCATION OF ALL OVERHEAD AND
UNDERGROUND UTILITIES PRIOR TO CONSTRUCTION. CONTRACTOR
SHALL COORDINATE WITH CITY OFFICIALS AND UTILITY COMPANIES
IN LOCATING UTILITIES. CONTRACTOR SHALL BE HELD RESPONSIBLE
FOR LOSSES DUE TO DAMAGE TO UTILITIES. LOCATION FOR ALL
UTILITIES SHOWN ON PLANS ARE APPROXIMATE. CONTRACTOR
SHALL CALL TEXAS 811, 1-800-344-8377.
N
0 10' 20'
CONTROL POINT #28
SET 5/8"
CONTROL POINT #26
SET 5/8"
N - 10092237.08 E - 3120097.49
ELEV. - 672.60
N - 10092262.50 E - 3120195.48
ELEV. - 670.68
BENCHMARK #31
BM ON TRANSFORMER PAD
N - 10092294.07 E - 3119994.93
ELEV. - 676.23
CONTROL POINT #29
SET 5/8"
N - 10092291.23 E - 3120138.99
ELEV. - 672.11
GENERAL DEMOLITION NOTES
EXAMINATION OF SITE OF WORK
BEFORE SUBMITTING A BID, EACH BIDDER SHALL CAREFULLY EXAMINE THE
SITE OF WORK. EACH BIDDER SHALL INFORM HIMSELF/HERSELF PRIOR TO
BIDDING AS TO THE EXISTING CONDITIONS AND LIMITATIONS UNDER WHICH
THE WORK IS TO BE PERFORMED, AND SHALL INCLUDE IN HIS/HER BID A
SUM TO COVER ALL COSTS OF ALL ITEMS NECESSARY TO PERFORM THE
WORK AS SET FORTH IN THE CONTRACT DOCUMENTS. NO ALLOWANCE WILL
BE MADE TO ANY BIDDER BECAUSE OF LACK OF SUCH EXAMINATION OR
KNOWLEDGE. THE SUBMISSION OF A BID SHALL BE CONSTRUED AS
CONCLUSIVE EVIDENCE THAT THE BIDDER IS SUFFICIENTLY FAMILIAR WITH
ALL RELEVANT CONDITIONS.
DEMOLITION
1. THE CONTRACTOR SHALL NOT ASSUME THAT UTILITIES ARE PRECISELY
LOCATED. UTILITIES ARE SHOWN TO HELP MAKE THE CONTRACTOR
AWARE OF THEIR EXISTENCE. THIS MEASURE IS TAKEN TO HELP
PROTECT THE INVESTMENTS AND SERVICES OF THE OWNERS, OF THE
UTILITIES AND THEIR CUSTOMERS. THE CONTRACTOR SHALL CALL
TEXAS 811 FOR HELP IN LOCATING UTILITIES.
2. IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE AND VERIFY
THE EXACT LOCATION AND DEPTH OF ALL EXISTING UTILITIES PRIOR TO
PROCEEDING WITH CONSTRUCTION. THE CONTRACTOR SHALL
ASCERTAIN WHETHER ANY ADDITIONAL UTILITIES OR FACILITIES, OTHER
THAN THOSE SHOWN ON THE PLANS, MAY BE PRESENT ON THE SITE OF
THE WORK.
3. PRIOR TO PROCEEDING WITH CONSTRUCTION, THE CONTRACTOR SHALL
NOTIFY THE OWNER OR A/E IF CONFLICTS OR POTENTIAL CONFLICTS
OCCUR BETWEEN EXISTING UTILITIES AND THE PROPOSED
CONSTRUCTION.
4. THE CONTRACTOR WILL IMMEDIATELY NOTIFY THE UTILITY OWNER AND
MAKE RESTITUTION FOR ANY UTILITY THAT IS DAMAGED BY THE
CONTRACTOR DURING THE COURSE OF THE WORK.
5. THE CONTRACTOR WILL IMMEDIATELY NOTIFY THE OWNER AND MAKE
RESTITUTION FOR ANY DAMAGE TO THE EXISTING FACILITIES BY THE
CONTRACTOR DURING THE COURSE OF THE WORK.
6. ALL TREES TO REMAIN UNLESS OTHERWISE NOTED.
7. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL MISCELLANEOUS
REPAIRS DUE TO DEMOLITION ACTIVITIES.
8. DISPOSAL OF ALL EXCESS / WASTE MATERIALS IS TO BE MADE AT A
REGISTERED LANDFILL.
9. TXDPS HAS FIRST RIGHT OF REFUSAL ON ALL EQUIPMENT BEING
DEMOED AS PART OF THIS PROJECT BEFORE DISPOSAL, INCLUDING ATS,
EQUIPMENT & GENERATOR.
SURVEY LEGEND
EXISTING FENCE TO BE REMOVED
DEMO LEGEND
EXISTING 1' CONTOUR
EXISTING 5' CONTOUR
SANITARY SEWER LINE
WATER LINE
UNDERGROUND ELECTRIC
GAS LINE
ELECTRICAL MANHOLE
ELECTRICAL BOX ABOVE GROUND
ELECTRICAL METER
GAS METER
IRRIGATION VALVE
TRANSFORMER
WATER VALVE
LIGHT POLE
SANITARY SEWER CLEANOUT
BOLLARD
UE UE UE
G G G
S S S
W W W
E
EE
E
E
E
E
E E
E
E
E
E
E
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
N = 10092246.63 E = 3120089.71
N = 10092240.87 E = 3120086.09
N = 10092257.23 E = 3120094.46
N = 10092255.45 E = 3120106.68
N = 10092226.18 E = 3120115.09
N = 10092234.65 E = 3120113.23
N = 10092243.38 E = 3120117.68
11.5'
20.3'
22.1'
32.1'
4.5'
(TYP.)
4.5'
(TYP.)
18.4'
27.0'
26.4'
9.8'
N = 10092252.03 E = 3120104.67
N = 10092246.08 E = 3120124.71
N = 10092255.36 E = 3120094.16
1.2'
Parkhill.com
PROJECT NO.
CLIENT
# DATE DESCRIPTION
KEY PLAN
A:
\2
6\
6.
\0 3_
D
SG
N \0
1_ D
W G
\0
_C
IV
IL
\0
3_
SH
EE
TS
\C C
1-
6.
D
W G
, 7 /2
9/
:5
PM
, c ha ds al l
Te xa s D ep ar tm en t o f P ub lic
S af et y
B ui ld in g G
G en er at or
Texas Department of Public Safety 5805 N Lamar Boulevard Austin, Tx 78752
47366.26
- 07/29/2026 Issue for Proposal
PRO
FESS I ONA L ENG I N
EERL
I C E N S E
D
STATE OF TEXAS
CASEY A. HADSALL
139380
PA
R
K H
I L L
S
M I TH & COOPER , I NC
. F
- 5
7/29/2026
CC101
Construction Layout
EXISTING UTILITIES
CONTRACTOR MUST VERIFY LOCATION OF ALL OVERHEAD AND
UNDERGROUND UTILITIES PRIOR TO CONSTRUCTION. CONTRACTOR
SHALL COORDINATE WITH CITY OFFICIALS AND UTILITY COMPANIES
IN LOCATING UTILITIES. CONTRACTOR SHALL BE HELD RESPONSIBLE
FOR LOSSES DUE TO DAMAGE TO UTILITIES. LOCATION FOR ALL
UTILITIES SHOWN ON PLANS ARE APPROXIMATE. CONTRACTOR
SHALL CALL TEXAS 811, 1-800-344-8377.
8" GENERATOR PAD (PER DET. B6/CC501)
6" CONCRETE PAVING (PER DET. A5/CC501)
'TIFTUF' BERMUDA GRASS SOD
8' ORNAMENTAL FENCE (PER DET. C3/CC501)
ENTRY GATE (PER DET. C3/CC501)
STEEL BOLLARD (PER DET. D6/CC501)
PROPOSED 1' CONTOUR
PROPOSED 5' CONTOUR900
CONSTRUCTION LEGEND
XX
SURVEY LEGEND
EXISTING 1' CONTOUR
EXISTING 5' CONTOUR
SANITARY SEWER LINE
WATER LINE
UNDERGROUND ELECTRIC
GAS LINE
ELECTRICAL MANHOLE
ELECTRICAL BOX ABOVE GROUND
ELECTRICAL METER
GAS METER
IRRIGATION VALVE
TRANSFORMER
WATER VALVE
LIGHT POLE
SANITARY SEWER CLEANOUT
BOLLARD
UE UE UE
G G G
S S S
W W W
CONSTRUCTION NOTES
EXAMINATION OF SITE OF WORK
BEFORE SUBMITTING A BID, EACH BIDDER SHALL CAREFULLY EXAMINE THE
SITE OF WORK. EACH BIDDER SHALL INFORM HIMSELF/HERSELF PRIOR TO
BIDDING AS TO THE EXISTING CONDITIONS AND LIMITATIONS UNDER WHICH
THE WORK IS TO BE PERFORMED, AND SHALL INCLUDE IN HIS/HER BID A
SUM TO COVER ALL COSTS OF ALL ITEMS NECESSARY TO PERFORM THE
WORK AS SET FORTH IN THE CONTRACT DOCUMENTS. NO ALLOWANCE WILL
BE MADE TO ANY BIDDER BECAUSE OF LACK OF SUCH EXAMINATION OR
KNOWLEDGE. THE SUBMISSION OF A BID SHALL BE CONSTRUED AS
CONCLUSIVE EVIDENCE THAT THE BIDDER IS SUFFICIENTLY FAMILIAR WITH
ALL RELEVANT CONDITIONS.
CONCRETE FORMWORK AND REINFORCEMENT
THE CONTRACTOR SHALL NOTIFY THE OWNER'S REPRESENTATIVE A
MINIMUM OF 48 HOURS PRIOR TO THE PLANNED PLACEMENT OF CONCRETE.
THE OWNER'S REPRESENTATIVE MUST HAVE OBSERVED AND APPROVED
THE FORMWORK AND REINFORCEMENT PRIOR TO ANY PLACEMENT OF
CONCRETE
SAW JOINTS
ALL SAW JOINTS SHALL BE SAWN WITHIN 24 HOURS OF CONCRETE
PLACEMENT. ANY CONCRETE SAWN LATER THAN THIS WHICH, IN THE
OPINION OF THE OWNER'S REPRESENTATIVE, HAS EXCESSIVE SHRINKAGE
CRACKS DUE TO NOT HAVING BEEN SAWN SOON ENOUGH, SHALL BE
REMOVED AND REPLACED AT THE CONTRACTOR'S EXPENSE.
ALIGNMENT AND TANGENCY OF PAVEMENTS
THE EDGES OF ALL FINISHED PAVING SHALL BE STRAIGHT OR SMOOTH
CURVES (AS DELINEATED ON THE PLANS) WITH NO INTERRUPTIONS SUCH
AS CHORDS, WAVES, JOGS, OR MISSED TANGENTS. PAVEMENT WITH SUCH
INTERRUPTION SHALL BE REMOVED.
DIMENSIONS
DIMENSIONS ARE TO BACKS OF CURBS, TO CENTERLINES OF FENCES, OR
TO EDGES OF PAVEMENTS, UNLESS OTHERWISE INDICATED. WRITTEN AND
NUMBERED DIMENSIONS HOLD PRECEDENCE OVER SCALED DIMENSIONS.
ADJUSTMENTS
IF THE CONTRACTOR BELIEVES IT IS NECESSARY TO MAKE AN ADJUSTMENT
IN THE LAYOUT OR GRADE OF PROPOSED IMPROVEMENTS, SUCH AN
ADJUSTMENT SHALL BE PROPOSED TO THE OWNER'S REPRESENTATIVE. NO
ADJUSTMENT WILL BE PERMITTED UNTIL IT HAS FIRST BEEN APPROVED BY
THE OWNER'S REPRESENTATIVE.
PLANTING NOTES
· ALL AREAS DISTURBED DURING CONSTRUCTION BY THE CONTRACTOR
SHALL BE SOLID SODDED AND MAINTAINED BY THE CONTRACTOR UNTIL
ACCEPTED BY THE OWNER.
· PRIOR TO BEGINNING SODDING AND SEEDING ACTIVITIES, ALL AREAS
SHALL BE FINE GRADED AND APPROVED BY THE OWNER PRIOR TO
PLANTING.
· ALL SODDED AND SEEDED AREAS SHALL BE MAINTAINED BY THE
CONTRACTOR INCLUDING MOWING AND IRRIGATION UNTIL ACCEPTED
BY THE OWNER.
N
0 5' 10'
CONTROL POINT #28
SET 5/8"
CONTROL POINT #26
SET 5/8"
N - 10092237.08 E - 3120097.49
ELEV. - 672.60
N - 10092262.50 E - 3120195.48
ELEV. - 670.68
BENCHMARK #31
BM ON TRANSFORMER PAD
N - 10092294.07 E - 3119994.93
ELEV. - 676.23
CONTROL POINT #29
SET 5/8"
N - 10092291.23 E - 3120138.99
ELEV. - 672.11
AS INDICATED BY: 00
KEY NOTES
1. NOT USED
2. 8" DIA. STEEL BOLLARD PER DETAIL D6/CC501
3. GENERATOR (REF ELECTRICAL SHEETS)
4. 6" CONCRETE PAVING PER DET A5/CC501
5. 8" GENERATOR PAD PER DET B6/CC501
6. CONNECT TO EXISTING CONCRETE PER DET C6/CC501
7. CONNECT TO EXISTING WALL PER DET C5/CC501
8. CONNECT CONC. PAVING TO GEN. PAD PER DET B5/CC501
9. NOT USED
10. EXISTING UNDERGROUND ELECTRICAL LINE.
NOTE: CONTRACTOR SHALL VERIFY DEPTH, DIAMETER, AND MATERIAL
OF EXISTING ELECTRICAL LINE. IF EXISTING ELECTRICAL LINE HAS
LESS THAN 2.0' OF COVER BETWEEN BOTTOM OF CONCRETE PAVING
AND TOP OF PIPE, CONTRACTOR SHALL CONTACT THE ENGINEER TO
REROUTE THE LINE.
11. DUAL PURPOSE DOCKING STATION (REF ELECTRICAL SHEETS)
12. ATS (REF ELECTRICAL SHEETS)
13. APPROXIMATE LOCATION OF EXISTING SAN SEWER LINE.
NOTE: CONTRACTOR SHALL VERIFY LOCATION, DEPTH, DIAMETER,
AND MATERIAL OF EXISTING SEWER LINE. IF EXISTING SEWER LINE IS
LOCATED BENEATH THE PROPOSED GENERATOR PAD OR HAS LESS
THAN 3.0' OF COVER BETWEEN BOTTOM OF CONCRETE PAVING AND
TOP OF PIPE, CONTRACTOR SHALL CONTACT THE ENGINEER TO
REROUTE THE LINE.
14. APPROXIMATE LOCATION OF EXISTING WATER LINE.
NOTE: CONTRACTOR SHALL VERIFY LOCATION, DEPTH, DIAMETER,
AND MATERIAL OF EXISTING WATER LINE. IF EXISTING WATER LINE IS
LOCATED BENEATH THE PROPOSED GENERATOR PAD OR HAS LESS
THAN 3.0' OF COVER BETWEEN BOTTOM OF CONCRETE PAVING AND
TOP OF PIPE, CONTRACTOR SHALL CONTACT THE ENGINEER TO
REROUTE THE LINE.
15. 'TIFTUF' BERMUDA GRASS SOD
16. EXISTING WATER VALVE TO REMAIN. CONTRACTOR SHALL ADJUST
TOP OF VALVE TO MATCH FINISH GRADE OF PAVING.
NOTE: IF CONDUITS ARE RE-ROUTED THROUGH THE EXISTING
PARKING LOT, CONTRACTOR SHALL REMOVE AND REPLACE
EXISTING PAVEMENT AND CURB AND GUTTER PER DETAILS D5
& E5/CC501. CONTRACTOR SHALL REPAINT ANY REMOVED
PARKING STRIPING TO MATCH EXISTING.
Parkhill.com
PROJECT NO.
CLIENT
# DATE DESCRIPTION
KEY PLAN
A:
\2
6\
6.
\0 3_
D
SG
N \0
1_ D
W G
\0
_C
IV
IL
\0
3_
SH
EE
TS
\C C
1-
6.
D
W G
, 7 /2
9/
:5
PM
, c ha ds al l
Te xa s D ep ar tm en t o f P ub lic
S af et y
B ui ld in g G
G en er at or
Texas Department of Public Safety 5805 N Lamar Boulevard Austin, Tx 78752
47366.26
- 07/29/2026 Issue for Proposal
PRO
FESS I ONA L ENG I N
EERL
I C E N S E
D
STATE OF TEXAS
CASEY A. HADSALL
139380
PA
R
K H
I L L
S
M I TH & COOPER , I NC
. F
- 5
7/29/2026
CC501
Construction Details
4' -0
6"
10"
20" Ø
10"
D6 STEEL BOLLARD
SCALE: 3/4" = 1'-0" L_STL_BOLL_01.dwg
CONCRETE
FOOTING
# 4 BAR, WELDED
WASHED GRAVEL
FINISH GRADE
SLOPE FOR DRAINAGE
8" OD, 3/16" SCH 40 PIPE
FILLED WITH CONCRETE
( 6'-6" IN LENGTH )
FILL VOID WITH CONCRETE
NOTES:
1. COVER EXPOSED PORTION OF BOLLARD WITH SMOOTH
YELLOW BOLLARD SLEEVE.
A1 TYPICAL CONCRETE PAVING JOINT DETAILS ( PEDESTRIAN PAVING )
1 1/2"=1'-0" CONC_PVMT_TYP_JNT_DET
2" D
EE
P
TYP CONC PAVING
TYP 1/4'' TOOLED
RADIUS EDGE
DEPTH OF CUT TO BE 1/4'' DEPTH OF
SLAB PLUS 1/4''. MAKE ALL SAW
CUTS WITHIN 12 HR OF CONC POUR
TYP 1/4'' TOOLED
RADIUS EDGE
SEE ISOLATION
JOINT DETAIL
TYP CONC PAVING
1/2" ISOLATION JOINT MATERIAL
W/ 1" JOINT SEALER ABOVE,
COLOR TO MATCH ADJACENT
PAVING. WIDTH TO DEPTH
RATIO OF JOINT SEALANT
TO BE PER MANUF
RECOMMENDATIONS
TYP 1/4'' TOOLED
RADIUS EDGE
TYP CONC PAVING
FOAM BACKER ROD
PREMOLDED EXP JT
FILLER AS SPEC'D
ENLARGED TYPICAL ISOLATION JOINT DOWELED ISOLATION JOINTSEALED ISOLATION JOINTTOOLED CONTRACTION JOINT SAWCUT CONTRACTION JOINT
COMPACTED
SUBGRADE
DOWELS TO BE 24'' L x #4
SMOOTH BARS, SUPPORTED ON
DOWEL BASKETS 18'' OC CAP &
LIGHTLY GREASE ONE END
FINISH
GRADE
18'' 9" 9"
1 1/4" CLR
2"
3"
8"
14''
(TYP)
NOTE:
DOWEL ALL ADJOINING FOUNDATIONS,
PAVING AND OTHER LOCATIONS
INDICATED ON THE PLANS
6"
MIN
1' -0
8"
100'-0"
#4 AT 18" OC,
EACH WAY
TOP AND BOT
GENERATOR
ANCHORING TO
SLAB PER
MANUFACTURER
FINISH GRADE
B6 GENERATOR PAD
NOT TO SCALE
VA
R
IE
S
(R
EF
G R
AD
IN
G P
LA
N
1'-0"
C5 CONC PAVING AT VERTICAL PLANE
1 1/2"=1'-0" SECTION
CONC CURB, WALL, ETC
CAULKED JOINT, SEE
ENLARGEMENT DETAIL
TYPICAL CONC PAVING
SUBGRADE
AS SPEC'D IN THE
GEOTECHNICAL REPORT
CONCRETE PAVING AT VERTICAL PLANE
1/2" ISOLATION JOINT MATERIAL
W/ 1" JOINT SEALER ABOVE,
COLOR TO MATCH ADJACENT
PAVING. WIDTH TO DEPTH
RATIO OF JOINT SEALANT
TO BE PER MANUFACTURER
RECOMMENDATIONS
TYP 1/4'' TOOLED
RADIUS EDGE
TYP CONC PAVING
FOAM BACKER ROD
PREMOLDED EXP JT
FILLER AS SPEC'D
ENLARGED TYPICAL ISOLATION JOINT
B5 PAVING @ GENERATOR PAD
1"=1'-0" PVMT_@_BLDG_SLAB
GENERATOR
WALL BEYOND
GENERATOR PAD
DOWELS TO BE
21'' L, NO 4 SMOOTH BARS
@ 18'' OC, CAP
AND LUBE ONE END
SUBGRADE
AS SHOWN
ON PLANS
CONCRETE
PAVING
SONNEBORN RUBBER
JOINT SEALANT OR
APPROVED EQUAL,
COLOR TO MATCH CONC
8"6"
8"
SLOPE
NOTES:
· REF CONCRETE PAVING DETAIL AND
GENERATOR PAD DETAIL FOR PAVEMENT
THICKNESSES
A5 6" CONCRETE PAVING
SCALE: 1 1/2" - 1'-0" PVMT_CONC_5-6IN_PED_PAVN.dwg
DRY BRUSH FINISH
CONCRETE PAVING
1/2" R ON ALL
EDGES ( TYP )
FINISH GRADE
# 3 BARS,
18" OCEW
6" COMPACTED
CRUSHED LIMESTONE
VARIES - SEE PLAN
1"
( TYP )
3" CLR
6"
6"
FINISH GRADE
1/8" W. x 1 1/2" DEEP, 10'
O.C. UNLESS OTHERWISE
SHOWN ON PLANS
C6 CONNECTION TO EXISITNG CONCRETE
1"=1'-0" PVMT_CONC_SDWALK_CONN
EXISTING CONCRETE
1/2'' ISOLATION JOINT
W/ 1/2'' JOINT SEALER ABOVECONCRETE REINF
6" PROPOSED
CONCRETE
#3 BARS @ 18'' OCEW
12''
LAP
12''
3"
5"
6"
1/2"R
6"2"
6" 6"4 5/
6"
3"
3"
3"
( 3 ) # 4 BARS,
CONTINUOUS ( TYP )
2'-6"
D5 CONCRETE CURB & GUTTER
SCALE: 1 1/2" = 1'-0" PVMT_CONC_CURB_GUTR.dwg
4" R
2" R
E5 HMAC PAVEMENT REPAIR
SCALE: 1" = 1'-0" PVMT_HMAC_REPR.dwg
6"
VA
R
IA
BL
E
2"
MC-70 PRIME COAT
( 0.40 GAL / SY )
2" HOT MIX ASPHALTIC
CONCRETE ( HMAC)
( FINE GRADED
SURFACE COURSE ) EXISTING
PAVEMENT
EXISTING
PAVEMENT
6" CRUSHED STONE
COMPACTED TO 95%
STANDARD DENSITY
NATIVE MATERIAL TO BE
MECHANICALLY COMPACTED
IN 6" LIFTS TO 95% STD
PROCTOR DENSITY
E
EE
E
E
E
E
E E
E
E
E
E
E
X
X
X
X
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G G
G G
G G
G G
G G
G G
G G
G
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
1.2
TS 673.10
TP 672.96
METC 672.90
METC 672.57
METC 671.87
TP/FL 671.90
METP 671.92
METP 672.57
METP 672.61
METP 673.06
TS 673.10
TP 673.06
TS 673.10
TP 672.15
TS 673.10
TP 672.15
TP 672.39
TS 673.10
TP 672.64
MEG 671.24
MEG 671.3 (VERIFY)MEG 671.8
MEG 671.6
0.7
1.5
1.8%
3.1%
1.8%
TP/FL 672.37
TP/FL 672.330.6%
TG 671.56
TP 672.35
4.2%
Parkhill.com
PROJECT NO.
CLIENT
# DATE DESCRIPTION
KEY PLAN
A:
\2
6\
6.
\0 3_
D
SG
N \0
1_ D
W G
\0
_C
IV
IL
\0
3_
SH
EE
TS
\C G
1-
6.
D
W G
, 7 /2
9/
:5
PM
, c ha ds al l
Te xa s D ep ar tm en t o f P ub lic
S af et y
B ui ld in g G
G en er at or
Texas Department of Public Safety 5805 N Lamar Boulevard Austin, Tx 78752
47366.26
- 07/29/2026 Issue for Proposal
PRO
FESS I ONA L ENG I N
EERL
I C E N S E
D
STATE OF TEXAS
CASEY A. HADSALL
139380
PA
R
K H
I L L
S
M I TH & COOPER , I NC
. F
- 5
7/29/2026
CG101
Grading Plan
EXISTING UTILITIES
CONTRACTOR MUST VERIFY LOCATION OF ALL OVERHEAD AND
UNDERGROUND UTILITIES PRIOR TO CONSTRUCTION. CONTRACTOR
SHALL COORDINATE WITH CITY OFFICIALS AND UTILITY COMPANIES
IN LOCATING UTILITIES. CONTRACTOR SHALL BE HELD RESPONSIBLE
FOR LOSSES DUE TO DAMAGE TO UTILITIES. LOCATION FOR ALL
UTILITIES SHOWN ON PLANS ARE APPROXIMATE. CONTRACTOR
SHALL CALL TEXAS 811, 1-800-344-8377.
N
0 5' 10'
CONTROL POINT #28
SET 5/8"
CONTROL POINT #26
SET 5/8"
N - 10092237.08 E - 3120097.49
ELEV. - 672.60
N - 10092262.50 E - 3120195.48
ELEV. - 670.68
BENCHMARK #31
BM ON TRANSFORMER PAD
N - 10092294.07 E - 3119994.93
ELEV. - 676.23
CONTROL POINT #29
SET 5/8"
N - 10092291.23 E - 3120138.99
ELEV. - 672.11
THE EARTHWORK FOR THIS PROJECT IS A NECESSARY AND INCIDENTAL
PART OF THE WORK. IN THE CASE THAT THE EARTHWORK DOES NOT
BALANCE, THE CONTRACTOR IS RESPONSIBLE FOR ANY ADDITIONAL COSTS
ASSOCIATED WITH HAUL OFF OR IMPORT. THE TOTAL COST SHALL BE
INCLUDED IN THE BID PROPOSAL AS A LUMP SUM. PAYMENT WILL NOT BE
MADE ON A UNIT PRICE BASIS OR BY ANY OTHER SEPARATE MEASURED
PAYMENT METHOD.
1. BASE BID SHALL INCLUDE ALL EARTHWORK NECESSARY TO ESTABLISH
THE FINISHED GRADES AS SHOWN ON THIS PLAN. NO SEPARATE
PAYMENT WILL BE MADE.
2. REFER TO SPECIFICATIONS FOR DISPOSAL OF EXCESS MATERIAL.
3. ALL EARTHWORK SHALL CONFORM TO THE GEOTECHNICAL REPORT.
4. THE TOPOGRAPHIC SURVEY FOR THIS PROJECT SHALL BE DONE BY AN
INDEPENDENT REGISTERED, LICENSED SURVEYOR APPROVED BY THE
OWNER. THE SURVEYS SHALL BE SIGNED AND SEALED BY THE
APPROVED SURVEYOR.
5. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND GRADES, NEW
OR EXISTING PRIOR TO CONSTRUCTION, NOTIFY THE ENGINEER OF ANY
DISCREPANCIES WITH EXISTING OR NEW CONDITIONS. THE
CONTRACTOR SHALL EMPLOY A LICENSED PUBLIC SURVEYOR TO SET
ALL GRADES, SPOT ELEVATIONS, FLOW LINES, ETC.
PROPOSED 8" GENERATOR PAD
PROPOSED 6" CONCRETE PAVING
PROPOSED 1' CONTOUR
PROPOSED 5' CONTOUR
FLOWLINE PATH
PROPOSED SPOT GRADE
TOP OF CURB
TOP OF PAVING
TOP OF GENERATOR SLAB
TOP OF GRADE
FLOWLINE
MATCH EXISTING GRADE
MATCH EXISTING TOP OF PAVING
MATCH EXISTING TOP OF CURB
DIRECTION OF FLOW
TC
TP
TS
TG
FL
MEG
METP
METC
GRADING NOTES
GRADING LEGEND
898.50
SURVEY LEGEND
EXISTING 1' CONTOUR
EXISTING 5' CONTOUR
SANITARY SEWER LINE
WATER LINE
UNDERGROUND ELECTRIC
GAS LINE
ELECTRICAL MANHOLE
ELECTRICAL BOX ABOVE GROUND
ELECTRICAL METER
GAS METER
IRRIGATION VALVE
TRANSFORMER
WATER VALVE
LIGHT POLE
SANITARY SEWER CLEANOUT
BOLLARD
UE UE UE
G G G
S S S
W W W http://www.parkhill.com/
| Sheets |
| E-001 - Electrical Symbols, Legends & Abbreviations |
| E-501 - Electrical Riser Diagram |
File details come from the government source that posted it. Updated .