ESBD_464742_1761747436632_C3 FEN DET Revised 10-27-25.pdf

PDF 257 KB Posted

Attached to
RFP 735-2026-8247 Facilities Shops Yard Expansion
Solicitation number
735-2026-8247
Issued by
Upton County, Texas

About this file

This is a technical drawing document prepared by Corlett, Probst & Boyd, P.L.L.C., engineering firm based in Wichita Falls, Texas, for Midwestern State University. The document, revised on October 27, 2025, provides detailed fence specifications and installation details for the Facilities Shops Yard Expansion project located at the university's existing parking lot in the Highland Addition area. The project encompasses two types of fence configurations with specific material and construction requirements. Type I fencing features 1x8 red cedar board and batten planks stained to a height of 8 feet, supported by 2 7/8-inch schedule 40 galvanized metal poles set in concrete at 8-foot on-center maximum intervals with poles embedded at minimum 30 inches below finish grade. Type II fencing consists of 1x6 red cedar planks stained, with similar pole specifications. Both fence types utilize continuous 2x4 red cedar runners and 2x6 red cedar furring strips, all stained, with concrete bases and reinforcement consisting of two number 4 continuous reinforcing bars with number 3 bars at 24-inch centers. The drawing also includes specifications for concrete flume sections and sidewalk details with 5-inch thick concrete, 3000 PSI strength, reinforced with number 3 bars at designated spacing, and subgrade compaction requirements to 90 percent per ASTM D-698 standards.

The technical specifications indicate a comprehensive fence installation project requiring adherence to precise structural and material standards established by the consulting engineer, Devin G. Smith, Texas Professional Engineer No. 84012. The drawing reflects the revised project scope dated October 27, 2025, incorporating additional flume details as noted on the document. All materials are specified as red cedar with staining requirements, galvanized metal pole components, and reinforced concrete work with specific compaction and strength requirements. The documentation serves as the technical basis for contractor bidding and project execution under the RFP 735-2026-8247 solicitation, with all work subject to completion by March 1, 2026, and prevailing wage compliance requirements established by the state.

View the file

Other files

Show all 15

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

AutoCAD SHX Text

CORLETT, PROBST & BOYD, P.L.L.C.

AutoCAD SHX Text

WICHITA FALLS, TEXAS 76302

AutoCAD SHX Text

SHEET OF

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

PHONE (940)723-1455

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text

CHECKED

AutoCAD SHX Text

DRAWN

AutoCAD SHX Text S:\WALT\2025\25-0574\25-0574.DWG C3 FEN DET P-10/27/2025 4:06 PM S-10/27/2025 4:04 PM WALTER THOMPSON C3 FEN DET P-10/27/2025 4:06 PM S-10/27/2025 4:04 PM WALTER THOMPSONC3 FEN DET P-10/27/2025 4:06 PM S-10/27/2025 4:04 PM WALTER THOMPSON P-10/27/2025 4:06 PM S-10/27/2025 4:04 PM WALTER THOMPSONP-10/27/2025 4:06 PM S-10/27/2025 4:04 PM WALTER THOMPSON S-10/27/2025 4:04 PM WALTER THOMPSONS-10/27/2025 4:04 PM WALTER THOMPSON WALTER THOMPSONWALTER THOMPSON

AutoCAD SHX Text

ENGINEERS - SURVEYORS

AutoCAD SHX Text

TBPE F-279 TBPLS-100541-00

AutoCAD SHX Text

WAT

AutoCAD SHX Text

DGS

AutoCAD SHX Text

DGS

AutoCAD SHX Text 1" = 10'

AutoCAD SHX Text C3

AutoCAD SHX Text

AutoCAD SHX Text

SEPTEMBER, 2024

AutoCAD SHX Text

FENCE DETAILS

AutoCAD SHX Text

FOR EXISTING PARKING LOT

AutoCAD SHX Text

OUT OF BLOCK 46, HIGHLAND ADDITION

AutoCAD SHX Text

MIDWESTERN STATE UNIVERSITY

AutoCAD SHX Text

WICHITA FALLS, WICHITA COUNTY, TEXAS

AutoCAD SHX Text

4605 OLD JACKSBORO HIGHWAY

AutoCAD SHX Text

BASIS OF BEARINGS ARE NAD 83 - TEXAS NORTH CENTRAL

AutoCAD SHX Text

WO#25-0574

AutoCAD SHX Text

DEVIN G. SMITH

AutoCAD SHX Text

REGISTERED PROFESSIONAL ENGINEER NO. 84012

AutoCAD SHX Text 84012

AutoCAD SHX Text A

AutoCAD SHX Text

DEVIN G. SMITH

AutoCAD SHX Text E

AutoCAD SHX Text F

AutoCAD SHX Text R

AutoCAD SHX Text O

AutoCAD SHX Text P

AutoCAD SHX Text S

AutoCAD SHX Text I

AutoCAD SHX Text S

AutoCAD SHX Text O

AutoCAD SHX Text N

AutoCAD SHX Text S

AutoCAD SHX Text T

AutoCAD SHX Text A

AutoCAD SHX Text T

AutoCAD SHX Text E

AutoCAD SHX Text O

AutoCAD SHX Text N

AutoCAD SHX Text I

AutoCAD SHX Text G

AutoCAD SHX Text E

AutoCAD SHX Text L

AutoCAD SHX Text N

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text S

AutoCAD SHX Text X

AutoCAD SHX Text A

AutoCAD SHX Text F

AutoCAD SHX Text T

AutoCAD SHX Text E

AutoCAD SHX Text

8'-0" (AS ACCEPTED W/ADD. ALT. NO. 2)

AutoCAD SHX Text 2'-6"

AutoCAD SHX Text 2-#4's CONT. W/ #3 AT 24" C/C

AutoCAD SHX Text 1x8 RED CEDAR BOARD & 1x2 BATTEN PLANKS (STAINED)

AutoCAD SHX Text CONT. 2x6 RED CEDAR FURRING STRIP (STAINED)

AutoCAD SHX Text 5 1/2"

AutoCAD SHX Text 10"

AutoCAD SHX Text 2 7/8" SCHED. 40 GALV. METAL POLE w/ CAP @ 8'-0" O.C. MAX. - SET IN MIN. 12" CONCRETE

AutoCAD SHX Text

MIN. 30" BELOW LOWEST FINISH GRADE

AutoCAD SHX Text 1'-0"

AutoCAD SHX Text CONT. 2x4 RED CEDAR RUNNERS

AutoCAD SHX Text CONT. 2x4 RED CEDAR (STAINED)

AutoCAD SHX Text

CONT. CONC. BASE

AutoCAD SHX Text 2'-6"

AutoCAD SHX Text 2-#4's CONT. W/ #3 AT 24" C/C

AutoCAD SHX Text 1x6 RED CEDAR PLANKS (STAINED)

AutoCAD SHX Text 5 1/2"

AutoCAD SHX Text 10"

AutoCAD SHX Text 2 7/8" SCHED. 40 GALV. METAL POLE w/ CAP @ 8'-0" O.C. MAX. - SET IN MIN. 12" CONCRETE

AutoCAD SHX Text

MIN. 30" BELOW LOWEST FINISH GRADE

AutoCAD SHX Text 1'-0"

AutoCAD SHX Text CONT. RED CEDAR 2x4 RUNNERS

AutoCAD SHX Text

CONT. CONC. CAP

AutoCAD SHX Text 2'-6"

AutoCAD SHX Text 2'-6"

AutoCAD SHX Text 2'-6"

AutoCAD SHX Text 4"

AutoCAD SHX Text

TYPE I FENCE DETAIL NOT TO SCALE

AutoCAD SHX Text

TYPE II FENCE DETAIL NOT TO SCALE

AutoCAD SHX Text

TYPE I FENCE ELVATION NOT TO SCALE

AutoCAD SHX Text

TYPE II FENCE ELVATION NOT TO SCALE

AutoCAD SHX Text

3/8" STEEL PLATE

AutoCAD SHX Text 2'-6"

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text

TYPICAL SECTION OF SIDEWALK FLUME

AutoCAD SHX Text

SIDEWALK

AutoCAD SHX Text

RECESSED ANCHOR BOLTS AT 2 FOOT CENTERS EACH SIDE.

AutoCAD SHX Text 2'-10"

AutoCAD SHX Text

FOOT

AutoCAD SHX Text

PER

AutoCAD SHX Text 1/4"

AutoCAD SHX Text

5" THICK 3000 PSI CONCRETE WITH NO. 3 BARS AT 12" O.C.E.W.

AutoCAD SHX Text

COMPACT 6" RAW SUBGRADE TO 90% ASTM D-698

AutoCAD SHX Text 12"

AutoCAD SHX Text

TYP.

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text

TYPICAL SECTION OF 2'-6" CONCRETE FLUME

AutoCAD SHX Text

NO. 3 BARS AT 18" O.C.E.W. DOWEL INTO PROPOSED PAVEMENT AND CURB

AutoCAD SHX Text

6" TYP.

AutoCAD SHX Text

AutoCAD SHX Text

REVISED 10-27-25: ADDED FLUME DETAILS

AutoCAD SHX Text dgs DGS Sig Date Stamp

Sheets and Views
C3 FEN DET

File details come from the government source that posted it. Updated .