635-2_Compartment_Thermal_Insulation.pdf

PDF 26 KB Posted

Attached to
Dockside Repairs to NOAA Ship FERDINAND HASSLER Federal contract opportunity
Solicitation number
EA-133M-16-RP-A123
Issued by
Department of Commerce National Oceanic and Atmospheric Administration

About this file

Additional Info.

View the file

Other files for this federal contract opportunity

Other files attached to Dockside Repairs to NOAA Ship FERDINAND HASSLER, newest first.
File Type Posted
SF_30 _Amend_0007.pdf PDF
AMENDMENT_0007_REFERENCE_DOCUMENTS.exe EXE file
SF_30 _Amend_0006.pdf PDF
Declaration_of_Asbestos-freesigned.pdf PDF
SF_30 _Amend_0005.pdf PDF
SF_30 _Amend_0004.pdf PDF
SF_30 _Amend_0003.pdf PDF
Section_G.pdf PDF
SF_30 _Amend_0002.pdf PDF
Section_M.pdf PDF
SF_30 _Amend_0001.pdf PDF
Section_M._Replacement_Pages.pdf PDF
Section_B._Replacement_Page.pdf PDF
RFP.pdf PDF
M286-430-PE41-001-03(As-Built).pdf PDF
8010-100-466_X06_R3.pdf PDF
M286-430-PE41-001-03(As-Built)_(1).pdf PDF
FC61_-_Paint_Schedule.pdf PDF
M286-430-PE41-001-03(As-Built)_(1)_(1).pdf PDF
s6900_ElecElex_General_Reqts.pdf PDF
RFP_ATTACHMENT_J.4.pdf PDF
RFP_ATTACHMENT_J.3.pdf PDF
M286-117-FC40-01-02_(PenetrationControlZones).pdf PDF
RFP_ATTACHMENT_J.2.pdf PDF
8010-100-466_X02_R3.pdf PDF
M286-085-FA11-001-07_(FIRE_CONTROL_PLAN)(As-Built).pdf PDF
NOAA_Std_Spec_S4800-2_Piping_Systems.pdf PDF
NOAA_Std_Spec_S4800-2_Piping_Systems_(1).pdf PDF
M286-085-FA02-001-15_(GARRGTS)_(As-Built).pdf PDF
M286-541-FP04-07_Fuel_Fill_Transfer_and_Service_Sys_Diag_(As.pdf PDF
RFP_ATTACHMENT_J.5.pdf PDF
FC61_-_Paint_Schedule_(1).pdf PDF
S0100_NOAA_Spec_Implementation_and_Conduct_of_Checkpoints.pdf PDF
8010-100-466_X05_R3.pdf PDF
M286-529-FP01-10_(Bilge-Ballast-Fire).pdf PDF
M286-512-FP27-10(Machinery_Space_Ventilation).pdf PDF
8010-100-466_X04_R3.pdf PDF
M286-085-FA06-001-05_(FIRE_ZONE_BOUNDARY).pdf PDF
631-2D-Coating_Systems_for_Steel_Surfaces.pdf PDF
M286-635-FV10-001-03_(INSULATION).pdf PDF
IEEE_Std_45-2002.pdf PDF
8010-100-466_X03_R3.pdf PDF
M286-531-FP03-11_(Fresh_ _Potable_Water).pdf PDF
M286-301-FE08-03.pdf PDF
MOC-635-1.pdf PDF
J.1_HASSLER_FY16_DOCKSIDE_SPECIFICATION.pdf PDF
Spec_Paint_NAVSEA_Standard_Item_009-32_FY10.pdf PDF
NOT_ISSUEDM286-581-FH20-001-03_(ANCHOR_HANDLING_DETAILS)_(Asc.pdf PDF
8010-100-466_X01_R3_(1).pdf PDF
M286-505-FP25-00_(Std_Piping_Details).pdf PDF
Show all 50

Dockside Repairs to NOAA Ship FERDINAND HASSLER has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

AMC-635-2

OCTOBER 1989

NATIONAL OCEANIC AND ATMOSPHERIC ADMINISTRATION (NOAA)

ATLANTIC MARINE CENTER

STANDARD SPECIFICATION AMC-635-2

THERMAL INSULATION FOR COMPARTMENTS

1. SCOPE. This specification contains the general requirements for renewing and installing thermal insulation on shell plating, bulkheads, overheads, and other structure in compartments of NOAA ships.

2. REFERENCES.

a. NOAA Standard Specification AMC-000-1 (latest revision), General Requirements for Ship Repair Contract Work on NOAA Ships"

3. REQUIREMENTS.

3.1 Whenever removal or renewal of existing insulation is

necessary to accomplish the required work, the contractor shall remove and properly dispose of all existing insulation. If the existing insulation contains asbestos materials, comply with Section 4.11.7 of reference 2.a. All suspect materials shall be considered to contain asbestos unless proven to be otherwise.

The contractor may have samples analyzed by a qualified laboratory to prove or disprove the presence of asbestos.

3.2 Materials.

3.2.1 Fibrous glass faced thermal insulation board, complying with MIL-I-742, Type I, shall be used.

3.2.2 Fibrous glass tape shall comply with MIL-C-20079, Type II, Class 1.

3.2.3 Fibrous glass insulation felt shall comply with MIL-I-

22023, Type I, Class 6.

3.2.4 Epoxy adhesive shall comply with MIL-A-24456.

3.2.5 Latex adhesive shall comply with MIL-A-3316, Class 1, Grade A.

3.2.6 Vapor barrier coating compound shall comply with MIL-C- 19993.

3.3 Installation.

3.3.1 Secure insulation board to the specified surfaces using 3/16-inch diameter studs and press-fit metal caps. Aluminum studs shall be used if the specified surface is aluminum and cadmium-plated steel studs shall be used on steel surfaces.

3.3.2 In areas accessible for a stud gun, weld studs shall be used. In areas that are inaccessible for a stud gun, studs welded to a perforated pad may be bonded to ship's structure using epoxy adhesive. A maximum of 25-percent of the total number of studs required to secure insulation on each plane area bounded by stiffeners or bulkheads may be attached using adhesive.

3.3.3 Studs shall be spaced approximately 12 inches (maximum of 14 inches) apart on centers. Studs at the edges of each piece of insulation board shall be placed not more than 4 inches from the edge at maximum intervals of 12 inches. Sufficient studs must be used to hold the insulation board firmly and evenly against the surface.

3.3.4 Insulation on vertical surfaces shall extend from 6 inches above the deck to the overhead. Do not apply insulation to the vertical surface within 6 inchess of the deck. Along the lower edge of the insulation, install a metal buffer plate tack-welded to the surface and extending out from surface a distance equal to the insulation thickness.

3.3.5 Insulation board shall be cut and neatly fitted around

surface protrusions.

3.3.6 Install insulation on beams, frames, and stiffeners as

shown on attached Appendix A.

3.3.7 Cover all seams, joints, and edges of thermal insulation with fibrous glass tape using latex adhesive.

3.3.8 To all insulation installed in laundries, sculleries, galleys, drying rooms, and to all insulation installed on the warm side of refrigerated stores spaces, apply a vapor barrier consisting of three alternate brush coatings of white, orange, and white vapor barrier coating compound.

APPENDIX A

INSULATION INSTALLATION ON BEAMS, FRAMES AND STIFFENERS

THIS PAGE IS RESERVED FOR SKETCHES

SHOWING DETAILS FOR INSTALLING INSULATION.

IF YOUR COPY OF THIS SPECIFICATION DOES

NOT HAVE THE SKETCHES, CONTACT THE NOAA

ATLANTIC MARINE CENTER, MARINE ENGINEERING

DIVISION, TELEPHONE (804) 441-6201. FAILURE

TO OBTAIN THE SKETCHES DOES NOT RELIEVE THE

CONTRACTOR OF THE RESPONSIBILITY TO COMPLY

WITH THE REQUIREMENTS CONTAINED THEREON.

END OF SPECIFICATION