FRV40-225-059-010
DESCRIPTION, OPERATION, INSTALLATION AND
MAINTENANCE INSTRUCTIONS
Marine Sanitation Device Unit (MSD) Model: MX-5
Halter Marine, Inc.
13085 Seaway Rd.
P.O. Box 3029 Gulfport, MS 39505
50-SPNA-1-00031
PUBLISHED BY DIRECTION OF NOAA
FRV40-225-059-010
DESCRIPTION, OPERATION, INSTALLATION AND
MAINTENANCE INSTRUCTIONS
Marine Sanitation Device Unit (MSD) Model: MX-5
13085 Seaway Rd.
P.O. Box 3029 Gulfport, MS 39505
PUBLISHED BY DIRECTION OF NOAA
27 September 2005
RECORD OF CHANGES
Change No.
Date Title and/or Brief Description Signature of Validating Officer
APPROVAL AND PROCUREMENT RECORD PAGE
APPROVAL DATA FOR: FRV40-225-059-010
TITLE OF MANUAL: Marine Sanitation Device Unit
APPROVAL AUTHORITY: NOAA
Contract Number
Ship Applicability
Qty Of Manuals
Building Yard
50-SPNA-1-00031 FRV40-225 2 EA Halter Marine Inc.
REMARKS:
CERTIFICATION: It is hereby certified that FRV40-225-059-010 to be provided under contract 50-SPNA- 1-00031 has been approved by the approval data shown above.
Date:________________ Chand, LLC Mathews, LA 70375
CAGE CODE: 0D5X4
VALIDATION PERFORMANCE
Title of Publication
Marine Sanitation Device Unit
Contractor Sub-Contractor (If
Performing Validation)
Contract No.(s) and Purchase Orders, If Applicable
Chapter
Section Paragraph Date Validation Completed
Check here if Not Validated
Contents of this manual have been validated and certified to be applicable to the equipment furnished under the above procurement as specified for Validation.
Name & Authority of Validating Officer: Signature of Validating Officer:
FOREWORD
This manual is intended to clearly and accurately reflect the actual configuration of the installed equipment described for the FRV40-225 Marine Sanitation Unit. Users are urged to report instances noted wherein the manual does not achieve this objective.
This technical manual provides the instructions necessary to operate, maintain,and perform troubleshooting for the Marine Sanitation Unit. The text is broken down as follows:
Section 1- FAST Model MX-5 Operation & Maintenance
Section 2- Drawings
Section 3- Spencer Vortex Regenerative Blowers Installation, Operation, and Maintenance Instructions
Section 4- PUMPAK Mounting Instructions
Section 5- ELTECH Model A200 Tablet Feeder Instruction Manual
Section 6- Honeywell Valve Installation, Operating, and Maintenance Instructions
Section 7- Vibration Isolators
Section 8- Recommended Spare Parts
Section 9- Technical Manual Vacuum Sewage System General Information
Section 10- Technical Manual Control Panel Assembly
Section 11- Technical Manual Sewage Ejector Pump Assembly with Motor
Section 12- Technical Manual Wall-Mounted VT Elongated Vacuum Toilet Assembly
Section 13- Technical Manual Envirovac Vacuum Interface Valve Assembly
Section 14- Technical Manual Envirovac Vacuum Interface Valve Kit – Lift Application
SECTION 1
FAST MODEL MX-5 OPERATION &
MAINTENANCE
SECTION 2
DRAWINGS
SERVICE ENTRANCE EQUIPMENT
(BY OTHERS)
PDB1
PB1 ILPB
STOP BLOWER START BLOWER
31 -
SS1
PUMP
OFF
HAND AUTO
mr,,SS2FynTFLOCAL DEMOTE fi4
PUMP PUMP
STOP .__. START _
-[eJj-ô i o-[
REMOTE
5VAC
SIGNAL
FE
WET
L
91 ^
O
CR1
-*H ——
CR1 OLP
SS3
WATER MAKE UP
—————OFF—————
HAND AUTO
INTERPOSING
PUMP
RUN
TDPU
0-1023 MIN.
SET FOR 13 HRS.
WATER MAKE UP
DRY CONTACTS FOR REMOTE USE
HIGH BLOWER PUMPUM
SPARE
a
NCL
^DB1
UP
"UB
:LIP
U1P,B
MJX
ItP
JLB
U-PRI
;LIP
:PT
U-SEC
JB1
LPB
SS1.3
5S2
^1 1
:RI
3ASE
[01
3ASE
f̂ i
SPARES
i o i
HAMMOND 2P20166 + 18P1713 + 2ZPMF
GOULD 63133
GOULD ATDR8
GOULD ATDR8
GOULD 30323R
ABB A9-30-10-84
ABB CAL5-11
ABB TA25DU4.0
ABB TA25DU4.0
GOULD ATQR2
GOULD 30322R
HAMMOND PT200MAMJ
GOULD TRM2
ABB CBK-KPER + CB01
ABB CBK-KPIRL1G + CB10
ABB CBK-3MK + CB10 + CB10
ABB CBK-2AMK-CB1Q-CB10
ABB CBK-KLRL1G
S.D. 750XBXM4L-120A
CUSTOM CON. OT08PC
TIME MARK 360-120-1MIN.
CUSTOM CON. DTOSPC
EMM EF1
GOULD ATDR8
GOULD TRM2
GOULD ATDR2
SDENCO/B4ST *
8229 BRENTWOOD INDUSTRIAL DRIVE
BRENTWOOD, MO 63144-2814 U.S A.
PHONE: 314-645-6540 FAX. 314-645-6131
1HIS DRAWING AND INFORMATION CONTAINED THEREIN IS THE PROPERTY
OF SC1ENCO/FAST SYSTEMS AND IS LOANED WITH THE EXPRESSED
AGREEMENT THAT IT Will NOT BE REPRODUCED, COP/ED. OR OTHERWISE
DISTRIBUTED, DIRECTLY OR INDIRECTLY, AND WILL NOT BE USED IN
WHOLE OR IN PART, TO FURNISH ANY INFORMATION FOR THE MANU-
FACTURING OF EQUIPMENT OR APPARATUS WITHOUT WRITTEN PERMISSION
OF SCIENCO/FAST SYSTEMS FIRST OBTAINED AND SPECFIC TO EACH CASE.
SYSTEM
CUSTOMER
T'TLE CHLORINE SIMPLEX
3 HP PUMP 2 1/2 HP BLOWER
SCALE I DRAWN BY CHKD. APPD.
NONE INDQUIP
NEXT ASSEMBLY
SUBMITTAL 8-05-02
CONTRACT NO. MODEL NO. DRAWING NO. REV.
J-1247 XXXX 32638-M5S
SECTION 3
SPENCER VORTEX REGENERATIVE
BLOWERS INSTALLATION, OPERATION,
AND MAINTENANCE INSTRUCTIONS
Spencer® Vortex® Regenerative Blowers
Serial No:
Model No:
Installation, Operation and Maintenance Instructions
VB-007
VB-055
Important Read and become familiar with this manual prior to uncrating and installing your Spencer Vortex Blower. Following the instructions detailed here will help you realize its full potential of efficient service and extended lifespan. Damage resulting from failure to follow correct procedure will void the warranty.
The Spencer Turbine Company Windsor, Connecticut 06095 Form ZZ11
Contents I. General Page
Scope Limited Warranty Safety Precautions
II. Installation Locating, Mounting, Connecting Wiring
III. Operation Limits of Operation ..................... 4-5 Temperature Rise
IV. Disassembly and Reassembly General Disassembly Procedure Reassembly Cautions Locknut Torque
V. Vortex Blower Data Assembly Diagrams .................... 6-17 Parts Lists ........................... 6-17 Performance Curves ................... 6-17
VI. Troubleshooting Guide
I. General Scope Information contained in this manual relates to Vortex Blowers standard and explosion-proof motor models
VB-001S, VB-001, VB-002S, VB-002, VB-003S, VB-003,
VB-004S, VB-004, VB-007S, VB-007, VB-019S, VB-019,
VB-030S, VB-030, VB-037S, VB-037.VB-055, VB-075,
andVB-110.
Limited Warranty We warrant that this product will be free from defects in material and workmanship for a period of 18 months from date of shipment or 12 months from date of startup, whichever comes first. Within the warranty period, we shall repair or replace F.O.B. our Factory such products that are determined by us to be defective.
This warranty will not apply to any product which has been subjected to misuse, negligence, or accident, or misap-plied or improperly installed. This warranty will not apply to any product which has been disassembled, repaired, or otherwise altered by any persons not authorized by the Spencer Vortex Service Department.
On units which include thermal protection, the thermal protection must be connected as recommended.
The guarantee of the motor and control manufacturers will govern the extent of our guarantee on such equip-ment. Warranty work on motors and controls must be authorized by Spencer and must be performed in an authorized shop as designated by the manufacturers.
The Spencer Turbine Company reserves the right to invoice all expenses incurred when repairs are made in the field at the specific request of the customer.
No assemblies or parts of assemblies will be accepted for repair or replacement under this warranty without prior authorization by The Spencer Turbine Company. For complete warranty information, obtain Spencer's Form 706, "Terms and Conditions of Sales."
Safety Precautions Power sources, protective devices, and grounding provi-sions must be in accordance with wiring instructions provided in this manual.
Blower becomes hot during operation and may cause burns if touched.
Do not operate the blower under load conditions which exceed the rated full-load amps on the nameplate.
Do not install the blower in any area which may have an explosive atmosphere or which may contain flammable gases or liquids. Always provide proper ventilation. Do not install in any area which may subject the blower to corrosive liquids. Excessive moisture may cause electri-cal failure; install the blower in areas free from water or rain. Do not operate blower without motor cooling fan cover, or without impeller end cover.
Before installing blowers with explosion-proof motors, the buyer must check federal, state and local codes to see if such motors are appropriate for the intended appli-cation environment. It is the buyer's responsibility to determine the suitability of any product for a particular purpose.
Storage If machine is to be stored for an extended period of time, it must be carefully protected from dampness and dirt.
II. Installation Locating, Mounting, Connecting Ambient temperature at the installed location should not be less than -5° F or greater than 104° F. Relative humidity should not exceed 80%.
Mount the blower in a horizontal or vertical position as shown in Figure 1; VB-055, VB-075 and VB-110 models must be mounted only in a horizontal position.
Horizontal Vertical (VB-037 & small*
Never This
r) Way
Fig. 1 Mounting Positions
Remove protective coverings, such as vinyl tape or plastic plugs, from the inlet and outlet ports. For models VB-004 and larger, attach to system piping using threaded connection as provided. Avoid exces-sive stress caused by pipe connector tightening or by misaligned pipe on the inlet and outlet ports. Support piping by brackets or other means. Models VB-001, VB-002 and VB-003 are supplied with a patented (U.S. Patent 5,791,870) reversible flange with threaded pipe or tubing connections.
In the event the blower is located where dust, fibers, drops of water, or other particulates may be in the airstream, use a filter on the suction side of the piping. If foreign matter enters the impeller, it may clog, jam, or otherwise impair the blower performance.
Wiring Caution: Confirm that the power source is the same as that indicated on the unit's nameplate. Application of incorrect voltage or improper phase connection may cause motor failure or other damage.
Use conductors and devices (such as the circuit breakers, starters, and switches shown in Figure 3) that are suitable for the applications shown in Tables 1 and 2 and are in compliance with the National Electric Code and applicable local codes and regula-tions. Motor terminal connections are shown below Table 1.
Provide protection from overheating of the motor windings. Some models are equipped with built-in thermal protectors (see Table 1). Where applicable, connect the leads from the pilot-duty thermal protector to the magnetic starter as shown in Fig. 3.
Check the direction of rotation of the blower.
To reverse the direction or rotation:
1) for a single-phase motor, interchange motor leads 5 and 8.
2) for a three-phase motor, interchange any two of the three line connections.
Caution: Install a properly-sized overload device and disconnect in accordance with local codes and regu-lations and dedicated only to the Vortex Blower.
Furnish the Vortex Blower and all associated electrical devices with a proper ground in accordance with all local codes and regulations.
Circuit Broker or other suitable disconnect with Overload Relay
Pilot lamp
Fig. 3 Typical Wiring Diagram
The Spencer Turbine Company 600 Day Hill Road, Windsor, CT 06095-4706 TEL 800-232-4321 4- 860-688-8361 * FAX 860-688-0098
Table 1 Three-Phase Motor Data - Typical Values
60 Hertz Operation Model No.
Power (hp) Voltage (V) FL Amp (A) Voltage (V) FL Amp (A)
Model NO.
Power (hp) Voltage (V) FL Amp (A) Voltage (V) FL Amp (A)
VB-001
0.13
200-230/460 .5-.487.24
VB-030
208-230/460
10.6-10.2/5.1
VB-002
0.25
200-230/460
.86-.737.37
VB-037
200-230/460
13.2-12/6
4.8
VB-003
0.5
208-230/460
1.8-1 .67.8 0.8
VB-055
7.5
200-230/460
19.8-17.2/8.6
VB-004
0.75
200-230/460
2.3-2.4/1.2
0.96
VB-075
200-230/460
27.5-27.2/13.6
9.6
VB-007
1.5
200-230/460
2.7-2.8/1.4
1.4
VB-110
200-230/460
39-37/18.5
13.5
VB-019
2.5
200-230/460
7.2-6.6/3.3
2.1
50 Hertz Operation
Model No.
Power (hp) Voltage (V) FLAmp(A)
Model No.
Power (hp) Voltage (V) FLAmp(A)
VB-001
0.13
190-220/380-415
.5-.52A25-.26
VB-030
3.4
190/380-415 10.2/5.2-5.1
VB-002
0.21
190-220/380-415 .74-.66A37-.34
VB-037
4.2
190/380-415
11.8/5.9-5.6
VB-003
0.5
190/380-415 2/1 -.9
VB-055
6.25
190/380-415 17.6/8.8-8.2
VB-004
0.63
190/380-415 2.4/1.2-1.3
VB-075
8.33
190/380-415
27/13.5-14.5
VB-OQ7
1.25
190/380-415 2.8/1.4-1.5
VB-110
12.5
190/380-415 36/18-17
VB-019
2.1
190/380-415 6.6/3.3-3.1
NOTE: Thermostats are provided on the VB-004 and larger models.
MOTOR WIRING
Three-Phase Single-Phase Low Voltage High Voltage
• 41 * A A A
4 5 6
7 8 9 o n • 1 2 3
0 0 0
• 4 o <
Line Line
Low Voltage e — - -w —————— w ^
3 5
1 4
0 0
Line
Single-Phase High Voltage
3 5 2
0 • __ •
Line
4 8
Single Voltage
05 "4 n 1 <>8 o o
Line
NOTES: (1) For three-phase, interchange any two line connections to reverse shaft rotation
(2) For single-phase, interchange motor leads 5 and 8 to reverse shaft rotation
THERMOSTATS
VB-004 AND LARGER
Volts Amps Wiring
115 6.0
230 3.0
460 1.5
575 1.2
Table 2 Single-Phase Motor Data - Typical Values
60 Hertz Operation Model No.
Power (hp) Voltage (V) FLAmps(A)
VB-001 S
0.13
115/230
1.25/.63
VB-002S
0.25
115/230
2.3/1.15
VB-003S
0.5
115/230 5.2/2.6
VB-004S
0.75
115/208-230
9.6/5-4.8
VB-007S
1.5
115/208-230 12.4/6.5-6.2
VB-019S
2.5
115/208-230
22/11.5-11
VB-030S
115/208-230 34.8/18.5-17.4
VB-037S
20.8
50 Hertz Operation
Model No.
Power (hp) Voltage (V) FL Amps (A)
VB-001S
0.13
110/220 1.34/.67
VB-002S
0.21
110/220
2.1/1.05
VB-003S
0.5
110/220
5.6/2.8
VB-004S
0.63
100-110/220
9.9-11.6/5.8
VB-007S
1.25
100-110/220
12.7-12.4/6.2
VB-019S
2.1
100-110/220
22-21/10.5
VB-030S
3.3
100-110/220
42-38.6/19.3
VB-037S
4.2
The Spencer Turbine Company 600 Day Hill Road, Windsor, CT 06095-4706 TEL 800-232-4321 * 860-688-8361 * FAX 860-688-0098
Spencer-
Moc
Yearc
VORTEX* BLOWER
Je! No. Serial No
Maximum CFM Pressure ("H2O) Vacuum ("H2O)
60 Hz 50 Hz
Read Instruction manual before installing
The Spencer Turbine Company i production Windsor, CT 06095
(860) 688-8361 Manufactured in USA
Fig. 4 Typical Nameplate
III. Operation Limits of Operation Operation at flows less than those indicated by the solid line on the applicable performance curve will cause overheating of the unit and is to be avoided.
Maximum pressure and vacuum are indicated on the nameplate (see Fig. 4). These represent conditions at which the minimum allowable airflow (CFM) occurs.
Check the operating pressure or vacuum to assure that the pressure or vacuum remains less than maximum.
For continuous operation at low air volume (on the dotted portion of the performance curve), provide a bypass in the piping and operate at a lower pressure than maximum operating pressure. See Performance Curves, Section V.
Caution: Low flow conditions may produce heat levels which may cause burns. Do not touch the blower in operation.
Temperature Rise A NEMA Class F insulation system is used in the motor.
Maximum allowable winding temperature is 265°F. If a thermal protector or thermal relay activates because the temperature rise of the motor is higher than usual, inves-tigate and correct the problem. Explosion-proof motors use a NEMA Class B insulation. Typical causes of motor overheating are given in Section VI, Troubleshooting Guide.
IV. Disassembly and Reassembly
A. General
1. Precautions should be taken when disassembling or reassembling the blower. See Warranty Terms.
2. Keep all parts clean.
3. Do not overtighten bolts and screws.
SHIM BLOCK
Fig. 5 Impeller Puller
B. Disassembly Procedure (Reassembly is performed in reverse order)
Caution: Shims are used to adjust the gap between the impeller and casing. When disassembling, take care to note the quantity of shims and their thickness. The shim stack replacement must be the correct thickness to assure proper clearance and to avoid degradation of performance.
1. Remove impeller cover; remove screws, pull cover away from case.
2. Unfasten lock washer; remove nut and washer.
3. Remove impeller from shaft by one of the following methods:
a.manually pull the impeller outward, OR b.screw two bolts into tapped holes and pull on the bolts, OR (if the fit is tight)
c. use a puller assembly (not furnished) as shown in
Fig. 5.
4. Remove motor shaft key.
5. Remove case from motor; if necessary remove screws holding case to base and motor to case.
6. Remove shims from motor shaft if necessary; do not discard them. See Note above.
Caution: Motors are heavy. Lift motor on models larger than VB002 by the eyebolt on the motor with an aid from a lifting device.
C. Reassembly Guidance
1. The gap between the impeller and case is essential for proper performance of the unit. The shims between the shaft collar and impeller hub establish the spacing of this gap. In reassembly, before installing the impeller cover, check the gap between the impeller and case to assure that the measurement conforms to the gap specification on the assembly drawing (on the following pages) for your unit.
The Spencer Turbine Company 600 Day Hill Road, Windsor, CT 06095-4706 TEL 800-232-4321 + 860-688-8361 + FAX 860-688-0098
2. For models VB-004 to VB-110, remove the plug at the bottom of the case and check the gap with a feeler gage. Remove impeller and adjust shims if necessary to change gap. When adjustments and checks are complete, replace plug tightly to prevent air leakage,
a. For models VB-001 to VB-003, check gap anywhere along the periphery of the case to impeller mating surface.
3. Fasten impellers using lockwashers and locknuts.
Torque locknut to recommended torque values in Table 3. Bend a lockwasher tab down into a lock-washer slot.
4. Reattach the impeller cover.
Catalog No.
VB001, VB001S, VB002
VB002S, VB003, VB003S
VB004, VB004S
VB007, VB007S
VB019, VB019S
VB030, VB030S
VB037, VB037S
VB055
VB075
VB110
Recommended Torque (Ft-Lb)
Table 3 Locknut Torque
V. Vortex Blower Data Pages 7 through 17 present information about the various blower models. This information is important in understanding your blower's performance, in using the blower in the proper operating range, and in ordering parts that might be needed.
A. Assembly Diagrams At the top of each page is an assembly diagram of the unit. Items are identified by circled numbers around the diagram. Above each diagram is the gap specification.
B. Parts Lists At the lower left of each diagram is a table giving the item number (shown on the Assembly Diagram), the Part No. for that item and the corresponding part description. In ordering parts, provide the model number, the part number and the description.
C. Performance Curves At the lower right of each diagram are performance curves for 50Hz and 60Hz operation. The curves present the following information:
The upper line of each curve is pressure performance while the lower line is vacuum performance. The dashed portion at the left end of some of the curves indicates an intermittent-only operating area. See Operation Section on page 5.
D. Estimated Acoustical Noise Level at 1.5M, 60Hz
Model
VB001S
VB001
VB002S
VB002
VB003S
VB003
VB004S
VB004
VB007S
VB007
VB019S
VB019
VB030S
VB030
VB037S
VB037
VB055
VB075
VB110
dba
The Spencer Turbine Company 600 Day Hill Road, Windsor, CT 06095-4706 TEL 800-232-4321 + 860-688-8361 + FAX 860-688-0098
Spencer® Vortex® Regenerative Blowers
VB001S, VB001
Assembly Diagram
(12
Parts List
DESCRIPTION VORTEX BLOWER ASSEMBLY - VB001 S & VB001
ITEM
7A
PART NO
VBC90101
VBI90101
VBE90101
NUT90219
WSH90184
WSH90185
MOT90210
MOT90215
SCR90901
SCR90307
GSK90168
FLC90013
SCR90888
INS90014
KEY90083
N/A
DESCRIPTION
Case, Unibody Impeller Cover, Impeller Locknut, Shaft Lockwasher, Shaft Shim, Shaft to Impeller (as required) Motor 42C 1/8 HP, 1 Ph Motor 42C 1/8 HP, 3 Ph M4 x 0 7 Pan Head Phillips Screw x 31 [8] Long 1/4-20 x 625" Long Socket Cap Screw Gasket, Flange Flange M5 x 0 8 Hex Head Bolt x 63 [16] long Absorber Key Impeller to case gap specification
QTY
N/A
VB001S, VB001
Performance Curves
VB001 Vortex Performance
VB001 Vortex Performance
The Spencer Turbine Company 600 Day Hill Road, Windsor, CT 06095-4706 TEL 800-232-4321 + 860-688-8361 + FAX 860-688-0098
VB002S, VB002
Assembly Diagram mm.
VB002S, VB002
Parts List
DESCRIPTION: VORTEX BLOWER ASSEMBLY - VB002S & VB002
ITEM
7A
PART NO.
VBC90201
VBI90201
VBE90201
NUT90219
WSH90184
WSH90185
MOT90211
MOT90212
SCR90901
SCR90307
GSK90169
FLC90014
SCR90888
INS90015
KEY90085
N/A
DESCRIPTION
Case, Unibody Impeller Cover, Impeller Locknut, Shaft Lockwasher, Shaft Shim, Shaft to Impeller (as required) Motor 42C, 1/4 HP, 1 Ph Motor 42C, 1/4 HP, 3Ph M4 x 0.7 Pan Head Phillips Screw x .31 [8] Long 1/4-20 x .625" Long Socket Cap Screws Gasket, Flange Flange M5 x 0.8 Hex Head Bolt x .63 [16] Long Absorber Key Impeller to case gap specification
QTY.
N/A
Performance Curves
VB002 Vortex Performance
Volume - CFM
VB002 Vortex Performance
The Spencer Turbine Company 600 Day Hill Road, Windsor, CT 06095-4706 TEL 800-232-4321 4- 860-688-8361 + FAX 860-688-0098
VB003S, VB003
Assembly Diagram in mm.
Parts List
DESCRIPTION: VORTEX BLOWER ASSEMBLY - VB003S & VB003
ITEM
7A 7B
PART NO.
VBC90301
VBI90301
VBE90301
NUT90219
WSH90184
WSH90185
MOT90213
MOT90214
MOT90229
SCR90901
SCR90307
GSK90170
FLC90015
SCR90888
INS90016
KEY90085
N/A
DESCRIPTION
Case, Unibody Impeller Cover, Impeller Locknut, Shaft Lockwasher, Shaft Shim, Shaft to Impeller (as required) Motor 48C, 1/2 HP, 1 Ph Motor 48C, 1/2 HP, 3 Ph Motor 48C, 1/2 HP, 3 Ph, 575 Volt M4 x 0.7 Pan Head Phillips Screw x .31 [8] Long 1/4-20 x .625" Long Socket Cap Screw Gasket, Flange Flange M5 x 0.8 Hex Head Bolt x .63 [16] Long Absorber Key Impeller to case gap specification
QTY.
N/A
VB003S, VB003
Performance Curves
VB003 Vortex Performance
VB003 Vortex Performance
The Spencer Turbine Company 600 Day Hill Road, Windsor, CT 06095-4706 TEL 800-232-4321 + 860-688-8361 + FAX 860-688-0098
VB004S, VB004
Assembly Diagram
VB004S, VB004
Parts List
DESCRIPTION: VORTEX BLOWER ASSEMBLY - VB004S & VB004
ITEM
8A 8B
PART NO.
VBC90401
VBI90401
VBB90401
VBE90401
NUT90212
WSH90170
WSH90177
MOT90193
MOT90192
MOT90230
SCR90887
WSH90142
WSH90166
SCR90888
WSH90181
SCR90877
WSH90138
WSH90139
SCR90307
GSK90165
GSK90163
FLC90007
SCR90931
PLG90037
INS90017
KEY90076
SEL90108
N/A
DESCRIPTION
Case Impeller Base Cover, Impeller Locknut, Shaft Lockwasher, Shaft Shim, Shaft to Impeller (as required) Motor 48C, 3/4 HP, 1 Ph Motor 48C, 3/4 HP, 3 Ph Motor 48C, 3/4 HP, 3 Ph, 575 Volt M6 x 1 .0 Hex Head Bolt x .63 [1 6] Long Lock washer, M5 Flat Washer, M5 M5 x 0.8 Hex Head Bolt x .63 [1 6] Long Flat Washer, M5 M5 x 0.8 Pan Head Phillips Screw x .39 [10] Long Lockwasher, M5 Flat Washer, M5 1/4-20 x .625" Long Socket Cap screw Gasket, Case Gasket, Flange Flange M6 x 1 .0 S.H.C.S. x .98 [25] Long Plug, 1/4 NPT x .43 [11] Long Absorber Key Lip Seal Impeller to case gap specification
QTY.
N/A
Performance Curves VB004 Vortex Performance
VB004 Vortex Performance
The Spencer Turbine Company 600 Day Hill Road, Windsor, CT 06095-4706 TEL 800-232-4321 4- 860-688-8361
FAX 860-688-0098
VB007S, VB007, VB007SXP, VB007XP
Assembly Diagram in.
,020 mm.
rn sii+' 004 CO. 103CO. 513_ 002 C0. 053"
(See Bulletin 417, pages 34 and 35 for specifics on models with explosion-proof motors.)
Parts List
DESCRIPTION VORTEX BLOWER ASSEMBLY - VB007S, VB007, VB007SXP, VB007XP
ITEM
8A 8B 8C 8D 8E 8F
28A
PART NO
VBC90701
VBI90701
VBB90701
VBE90701
NUT90210
WSH90171
WSH90160
MOT90195
MOT90194
MOT90231
MOT90376
MOT90375
MOT90225
MOT90358
SCR90887
WSH90142
WSH90166
SCR90888
WSH90181
SCR90877
WSH90138
WSH90139
SCR90867
GSK90164
GSK90163
FLC90008
SCR90931
PLG90037
INS90018
KEY90076
SEL90107
SEL90012
N/A
DESCRIPTION
Case Impeller Base Cover, Impeller Lockout, Shaft Lockwasher, Shaft Shim, Shaft to Impeller (as required) Motor, 56C, 1 HP, 1 Ph Motor, 56C 1 HP, 3 Ph Motor, 56C, 1 HP, 3 Ph, 575 Volt Motor, 56C, 1 HP, 3 Ph, XP, Motor, 56C, 1 HP, 1 Ph, XP Motor, 56C, 1-1/2 HP, 3 Ph, XP Motor, 56C, 1-1/2 HP, 1 Ph, XP M6 x 1 .0 Hex Head Bolt x .63 [1 6] Long Lockwasher, M6 Flat Washer, M6 M5 x 0 8 Hex Head Bolt x 63 [1 6] Long Washer, Flat M5 M5 x 0 8 Pan Head Phillips Screw x 39 [10] Long Lockwasher, M5 Flat Washer, M5 3/8-16 x .75" Long Socket Cap Screw Gasket, Case Gasket, Flange Flange, 1 1/2 FNPT M6 x 1 .0 S.H C S x 98 [25] Long Plug, 1/4NPTx.43[11]Long Absorber Key Lip Seal Viton Lip Seal Impeller to case gap specification
QTY.
N/A
VB007S, VB007
Performance Curves VB007 Vortex Performance
VB007 Vortex Performance
50 HZ
10 20 30 40 50 60 70 80 90 100 110
Volume ICFM
The Spencer Turbine Company 600 Day Hill Road, Windsor, CT 06095-4706 TEL 800-232-4321 4- 860-688-8361 + FAX 860-688-0098
VB019S, VB019, VB019SXP, VB019XP
Assembly Diagram
in. mm.
Parts List
(See Bulletin 417, pages 36 and 37 for specifics on models with explosion-proof motors.)
DESCRIPTION: VORTEX BLOWER ASSEMBLY - VB01 9S, VB01 9, VB01 9SXP, VB01 9XP
ITEM
8A 8B 8C 8D 8E 8F
9ALT
28A
PART NO.
VBC91901
VBI91901
VBB91901
VBE91901
NUT90210
WSH90171
WSH90160
MOT90254
MOT90249
MOT90347
MOT90372
MOT90378
MOT90224
MOT90359
SCR90887
SCR90876
WSH90142
WSH90166
SCR90943
WSH90181
SCR90877
WSH90138
WSH90139
SCR90867
GSK90162
GSK90163
FLC90008
SCR90931
PLG90037
INS90019
KEY90077
SEL90107
SEL90012
N/A
DESPCRIPTION
Case Impeller Base Cover, Impeller Locknut, Shaft Lockwasher, Shaft Shim, Shaft to Impeller (as required) Motor, 145TC, 2-1/2 HP, 1 Ph Motor, 145TC, 2-1/2 HP, 3 Ph Motor, 145TC, 2-1/2 HP, 3 Ph, 575 Volt Motor, 145TC, 2 HP, 3 Ph, XP, Motor, 145TC, 2 HP, 1 Ph, XP Motor, 145TC, 2-1/2 HP, 3 Ph, XP Motor, 145TC, 2-1/2 HP, 1 Ph, XP M6 x 1 .0 Hex Head Bolt x .63 [1 6] Long M6. x 1 .0 Hex Head Bolt x .98 [25] Long (Cast Motor) Lockwasher, M6 Flat Washer, M6 M5 x 0.8 Hex Head Bolt x .79 [20] Long Flat Washer, M5 M5 x 0.8 Pan Head Phillips Screw x .39 [10] Long Lockwasher, M5 Flat Washer, M5 3/8-16 x .75" Long Socket Cap Screw Gasket, Case Gasket, Flange Flange, 1 1/2 FNPT M6 x 1.0 S.H.C.S. x .98 [25] Long Plug, 1/4NPTx.43[11]Long Absorber Key Lip Seal Viton Lip Seal Impeller to case gap specification
QTY.
N/A
VB019S, VB019
Performance Curves
VB019 Vortex Performance qi i i
[6CH
m m
•JZj wm N\
>j
1 _, \
25 SO TS 100 125 150 175
Volume - ICFM
VB019 Vortex Performance
ES2
r-l-.— iSOHZ imr-r;^ k i
V\
0 25 50 75 100 125 150 17$
Volume - ICFM
The Spencer Turbine Company 600 Day Hill Road, Windsor, CT 06095-4706 TEL 800-232-4321 + 860-688-8361 + FAX 860-688-0098
VB030S, VB030, VB030XP
Assembly Diagram
in. mm.
(See Bulletin 417, pages 38 and 39 for specifics on models with explosion-proof motors.)
VB030S, VB030
Parts List
DESCRIPTION: VORTEX BLOWER ASSEMBLY - VB030S, VB030, VB030XP
ITEM
8A 8B 8C 8D 8E
28A
PART NO.
VBC93001
VBI93001
VBB93001
VBE93001
NUT90209
WSH90172
WSH90157
MOT90370
MOT90250
MOT90348
MOT90223
MOT90406
MOT90432
SCR90879
WSH90148
WSH90182
SCR90876
WSH90166
SCR90877
WSH90138
WSH90139
SCR90335
GSK90161
GSK90155
FLC90009
SCR90878
PLG90037
INS90020
KEY90078
SEL90104
SEL90109
N/A
DESCRIPTION
Case Impeller Base Cover, Impeller Locknut, Shaft Lockwasher, Shaft Shim, Shaft to Impeller (as required) Motor, 184TC, 4 HP, 1 Ph Motor, 182TC, 4 HP, 3 Ph Motor, 182TC, 4 HP, 3 Ph, 575 Volt Motor, 182TC, 4 HP, 3 Ph, XP, Motor, 182TC, 5 HP, 3 Ph, XP Motor, 182TC, 5 HP, 3 Ph, 575 Volt, XP M8 x 1 .25 Hex Head Bolt x .98 [25] Long Lockwasher, M8 Flat Washer, M8 M6 x 1 .0 Hex Head Bolt x .98 [25] Long Flat Washer, M6 M5 x 0.8 Pan Head Phillips Screw x .39 [10] Long Lockwasher, M5 Flat Washer, M5 1/2 -1 3 x 1 .0 Long Socket Cap Screw Gasket, Case Gasket, Flange Flange, 2 FNPT M6 x 1 .0 Hex Head Bolt x 1 .57 [40] Long Plug, 1/4NPTx.43[11]Long Absorber Key Lip Seal Viton Lip Seal Impeller to case gap specification
QTY.
N/A
Performance Curves
VB030 Vortex Performance
75 200 225
VB030 Vortex Performance
The Spencer Turbine Company 600 Day Hill Road, Windsor, CT 06095-4706 TEL 800-232-4321 + 860-688-8361 + FAX 860-688-0098
VB037S, VB037, VB037XP
Assembly Diagram
in. mm.
(See Bulletin 417, pages 40 and 41 for specifics on models with explosion-proof motors.)
VB037S, VB037
Parts List
DESCRIPTION VORTEX BLOWER ASSEMBLY - VB037S, VB037, VB037XP
ITEM
8A 8B 8C 28A
PART NO
VBC93701
VBI93702
VBB93700
VBE93701
NUT90209
WSH90172
WSH90157
MOT90361
MOT90181
MOT90234
MOT90222
SCR90879
WSH90148
WSH90182
SCR90878
WSH90166
SCR90877
WSH90138
WSH90139
SCR90335
GSK90154
GSK90155
FLC90009
SCR90878
PLG90037
INS90021
SCN90056
KEY90079
SEL90104
SEL90109
SPR90088
N/A
PLC90027
DESCRIPTION
Case Impeller Base Cover, Impeller Locknut, Shaft Lockwasher, Shaft Shim, Shaft to Impeller (as required) Motor, 184TC, 5 HP, 1 Ph Motor, 184TC, 5 HP, 3 Ph Motor, 184TC, 5 HP, 3 Ph, 575 Volt Motor, 184TC, 5 HP, 3 Ph, XP M8 x 1 25 Hex Head Bolt x 98 [25] Long Lockwash, M8 Flat Washer, M8 M6 x 1 0 Hex Head Bolt x 1 57 [40] Long Flat Washer, M6 M5 x 0 8 Pan Head Phillips Screw x 39 [10] Long Lockwasher, M5 Flat Washer, M5 1/2-13 x 1 0 Long Socket Cap Screw Gasket, Case Gasket, Flange Flange, 2 FNPT M6 x 1 0 Hex Head Bolt x 1 57 [40] Long Plug, 1/4NPTx 43 [11] Long Absorber Absorber Screen Key Lip Seal Viton Lip Seal Spacer, Washer (Case to Base) Impeller to case gap specification Plate, Case
QTY
N/A
Performance Curves
VB037 Vortex Performance
200 225 250 275 300
Volume ICFM
VB037 Vortex Performance
The Spencer Turbine Company 600 Day Hill Road, Windsor, CT 06095-4706 TEL 800-232-4321 » 860-688-8361 » FAX 860-688-0098
VB055, VB055XP
Assembly Diagram
in. mm.
(See Bulletin 417, pages 42 and 43 for specifics on models with explosion-proof motors.)
VB055
Parts List
DESCRIPTION: VORTEX BLOWER ASSEMBLY - VB055, VB055XP
ITEM
8A 8B 28A
PART NO.
VBC95501
VBI95502
VBB95501
VBE95501
NUT90211
WSH90173
WSH90154
MOT90182 j
MOT90205
MOT90221
SCR90881
WSH90148
WSH90182
SCR90895
WSH90182
SCR90876
WSH90143
WSH90142
SCR90335
GSK90156
GSK90157
FLC90010
SCR90878
PLG90037
INS90022
SCN90057
KEY90080
SEL90105
SEL91110
N/A
PLC90028
DESCRIPTION
Case Impeller Base Cover, Impeller Locknut, Shaft Lockwasher, Shaft Shim, Shaft to Impeller (as required) Motor, 213TC, 7-1/2 HP, 3PH Motor, 213TC, 7-1/2 HP, 3 Ph, 575 Volt Motor, 213TC, 7-1/2 HP, 3 Ph, XP M8 x 1 .25 Hex Head Bolt x 1 .18 [30] Long Lockwasher, M8 Flat Washer, M8 M8 x 1 .25 Hex Head Bolt x 1 .57 [40] Long Flat Washer, M8 M6 x 1 .0 Hex Head Screw x .98 [25] Long Lockwasher, M6 Washer, Flat M6 1/2-13 x 1 .0 Long Socket Cap Screw Gasket, Case Gasket, Flange Flange, 2-1/2 FNPT M6 x 1 .0 Hex Head Bolt x 1 57 [40] Long Plug, 1/4 NPTx. 43 [11] Long Absorber Absorber Screen Key Lip Seal Viton Lip Seal Impeller to case gap specification Case Plate
QTY.
N/A
Performance Curves VB055 Vortex Performance
VB055 Vortex Performance
50 HZ
150 200 250 300 350
Volume ICFM
The Spencer Turbine Company 600 Day Hill Road, Windsor, CT 06095-4706 TEL 800-232-4321 4- 860-688-8361 + FAX 860-688-0098
VB075
Assembly Diagram
in. mm.
Parts List
DESCRIPTION: VORTEX BLOWER ASSEMBLY - VB075
ITEM
8A
PART NO.
VBC97501
VBI97502
VBB97501
VBE97501
NUT90213
WSH90174
WSH90179
MOT90199
MOT90235
SCR90881
WSH90148
WSH90182
SCR90881
WSH90182
SCR90876
WSH90143
WSH90142
SCR90335
GSK90158
GSK90159
FLC90011
SCR90883
PLG90037
INS90023
SCN90058
KEY90081
SEL90106
SPR90089
N/A
PLC90029
DESCRIPTION
Case Impeller Base Cover, Impeller Locknut, Shaft Lockwasher, Shaft Shim, Shaft to Impeller (as required) Motor, 21 5TC, 10 HP, 3PH Motor, 215TC, 10 HP, 3 Ph, 575 Volt M8 x 1 .25 Hex Head Bolt x 1 .18 [30] Long Lockwasher, M8 Flat Washer M8 M8 x 1 .25 Hex Head Bolt x 1 .18 [30] Long Flat Washer M8 M6 x 1 .0 Hex Head Screw x .98 [25] Long lockwasher, M6 Flat Washer M6 1/2-13 x 1 .0 Long Socket Cap Screw Gasket, Case Gasket, Flange Flange, 3 FNPT M8 x 1.25 Hex Head Bolt x 2.165 [55] Long Plug, 1/4NPTx.43[11]Long Absorber Absorber Screen Key Lip Seal Spacer, Washer (Case to Base) Impeller to case gap specification Case Plate
QTY.
N/A
VB075
Performance Curves VB075 Vortex Performance
VB075 Vortex Performance
The Spencer Turbine Company 600 Day Hill Road, Windsor, CT 06095-4706 TEL 800-232-4321 + 860-688-8361 * FAX 860-688-0098
VB110
Assembly Diagram
in. mm.
VB110
Parts List
DESCRIPTION VORTEX BLOWER ASSEMBLY - VB1 10
ITEM
8A
PART NO
VBC91101
VBI91102
VBB91101
VBE91101
NUT90213
WSH90174
WSH90179
MOT90200
MOT90236
SCR90882
WSH90137
WSH90183
SCR90881
WSH90182
SCR90876
WSH90143
WSH90142
SCR90335
GSK90160
GSK90159
FLC90011
SCR90883
PLG90037
INS90024
SCN90061
KEY90082
SEL90106
SPR90089
N/A
PLC90030
DESCRIPTION
Case Impeller Base Cover, Impeller Locknut, Shaft Lockwasher Shaft Shim, Shaft to Impeller (as required) Motor, 254-6TC, 15 HP 3PH Motor, 254-6TC, 15 HP 3 Ph, 575 Volt M10 x 1 5 Hex Head Bolt x 1 57 [40] Long Lockwasher, M10 Flat Washer M10 M8 x 1 25 Hex Head Bolt x 1 1 8 [30] Long Flat Washer M8 M6 x 1 0 Hex Head Screw x 98 [25] Long Lockwasher, M6 Flat Washer M6 1/2-13 x 1 0 Long Socket Cap Screw Gasket, Case Gasket, Flange Flange, 3 FNPT M8 x 1 25 Hex Head Bolt x 2 16 [55] Long Plug, 1/4NPTX 43 [11] Long Absorber Absorber Screen Key Lip Seal Spacer, Washer (Case to Base) Impeller to case gap specification Case Plate
QTY
N/A
Performance Curves VB110 Vortex Performance
VB110 Vortex Performance
J_4
ISO HZ,
150 200 250 300 350 400 450 500 560 600
Volume ICFM
The Spencer Turbine Company 600 Day Hill Road, Windsor, CT 06095-4706 TEL 800-232-4321 4> 860-688-8361 4 FAX 860-688-0098
VI. Troubleshooting Guide Trouble Possible Cause Corrective Action
Blower Does Not Turn and there is -
A Humming Sound
No Sound
One phase of power line disconnected One phase of stator line open Bearing(s) defective Impeller jammed by foreign material Impeller jammed against casing or side cover Rubbing of rotor core and stator core Capacitor open (single-phase models)
Two phases of power line disconnected Two phases of stator winding open Faulty switch connection Fuse blown
Connect power leads properly Contact factory Change defective bearing(s) Clean impeller Adjust gap
Contact factory Change capacitor
Connect power leads properly Contact factory Change switch Change fuse
Blower Turns, but
Fuse Blows - Fuse capacity insufficient, wiring fault
- Short circuit
- Terminals shorted
- Excessive load
Inspect wiring Repair Improve insulation and check connections Increase air flow
Overheats or Thermal Protector Activates Power source unbalance; possible voltage drop
Operating in single-phase condition Excessive friction due to defective bearings Impeller contaminated by foreign material Impeller rubbing against casing or side cover Operation at less than minimum rated flow
Check voltage; phases must be balanced within 5% and voltage must be within 10% of rated Check connections Replace bearings Clean impeller Adjust gap Increase airflow
Makes Abnormal Sound Impeller rubbing against casing or side cover Impeller rubbed by foreign material Bearing(s) defective There is a leak or air passages are clogged Loose cap screw
Adjust gap Clean impeller Replace bearings Repair or clean Tighten screw
The Spencer Turbine Company 600 Day Hill Road, Windsor, CT 06095-4706 TEL 800-232-4321 4- 860-688-8361 + FAX 860-688-0098 t s.
Products & Services Industrially rated products offering effective solutions for air and gas moving problems:
• Modular central vacuum systems
• Mobile or stationary integrated vacuum units
• Dust collectors and separators
• Multi-stage centrifugal blowers
• Single stage centrifugal blowers
• Regenerative blowers
• Positive displacement blowers and packages
• Gas boosters
• Custom-engineered products with special materials for extreme temperatures and pressure
Complementary accessories with single source convenience and compatibility:
• Standard and custom electrical control panels - UL, CUL and C.E. Listed available
• Comprehensive selection of tubing, fittings, vacuum hoses, valves and tools
• Valves, gauges, couplings, shrink sleeves, vibration isolators and other system components
Comprehensive engineering and other customer support services:
• The industry's largest complement of technical specialists in air and gas moving technology
• Worldwide parts and service organization
• Application research and testing facility
• Product selection process aided by internal computer program
Worldwide organization of sales representatives and distributors offering:
• Product selection, installation and operation assistance
• Comprehensive system design services
• Follow-up services and troubleshooting
For the name and telephone number of your local Spencer Representative, call 1-800-232-4321 or email marketing@spencer-air.com.
The
Since 1892 moving air and gas for a cleaner environment
Turbine Company, 600 Day Hill Road, Windsor, CT 06095-4706 TEL 800-232-4321 * 860-688-8361 * FAX 860-688-0098 * www.spencerturbine.com
Form ZZ11, Copyright © 2003 The Spencer Turbine Company 1203CF4 0
SECTION 4
PUMPAK MOUNTING INSTRUCTIONS
PUMPAK MOUNTING INSTRUCTIONS
Self Priming Centrifugal Pumps
FLOMAX
11/2" —2-3" Pipe Size
Packed separately with each PUMPAK assembly are Mounting Instructions, Installation and Maintenance Instructions and Parts Lists. It is important that these bulletins be read over care-fully to fully familiarize yourself with the pump arrangement.
These Instructions pertain only to the mounting of PUMPAK assembly to driver.
Remove the contents from the shipping cartons and check them over carefully to make certain that no parts are missing or damaged in shipment. Cartons should contain the following parts.
1. PUMPAK assembly
2. Bag containing following:
Necessary lockwashers, capscrews and nuts.
WARNING: DO NOT REMOVE STRIP STOCK SPACER FROM FRONT OF IMPELLER
UNTIL PUMPAK HAS BEEN COMPLETELY ASSEMBLED TO THE DRIVER.
MOUNTING PUMPAK
Loosen impeller clamp nuts.
Do not use drive shaft key. Remove key if installed on drive shaft.
Slide PUMPAK assembly onto the drive shaft. WARNING! If PUMPAK does not slide freely — STOP — DO NOT HAMMER or force PUMPAK. Be sure impeller clamp is loose. PUMPAK assemblies should slide on with hand pressure. Check for and remove any burrs from drive shaft or bore of sleeve. Align holes in adapter with holes in driver mounting face and slide PUMPAK until adaptor contacts mounting face.
Attach capscrews and lockwashers and tighten to secure PUMPAK assembly to driver.
Tighten impeller clamp nuts to lock impeller onto drive shaft.
ADJUSTING IMPELLER CLEARANCE:
NOTE: A shipping spacer was inserted at the factory for the purpose of establishing the proper clearance between the face of impeller and the wear plate.
Remove strip stock spacer only after tightening the impeller.
Clearance between the impeller and wear plate is now set to approximately. 020". Turn over slowly to make certain pump rotates freely.
Loosen impeller clamp to adjust clearance between impeller and wear plate using a feeler gauge in place of spacer. After clearance has been established, tighten impeller clamp to lock impeller to shaft.
TECUMSEH PRODUCTS COMPAIMV
34800 BENNETT DRIVE - FRASER, Ml 48026-1686
293-82-4-O - FAX (586) 293-8-4-69
(8OO S63-8OOG)
www. mppumps. com
FORM 3002-F
PRINTED IN THE U.S.A. (6-02)