Consilium_Model_SAL_R1a_Doppler_Speed_Log_Installation_Manual_(Pages_106_-_196).pdf

PDF 4 MB Posted

Attached to
Dry Dock and Repairs to NOAA Ship Henry B. Bigelow
Solicitation number
EA-133M-15-RP-0125
Issued by

About this file

28

View the file

Other files

File Type Posted
HB_FY16_Dry_Dock_Spec_(09-23-15).pdf PDF
Questions_and_Answers_2.pdf PDF
SF_30_-_Amendment_0003.pdf PDF
SF_30_-_Amendment_0002.pdf PDF
Questions_and_Answers.pdf PDF
HB_FY16_Dry_Dock_Spec_(09-21-15).pdf PDF
SAL_T2_Installation_Manual.pdf PDF
HB-801_FC05_Tank_Capacity_Curves.pdf PDF
Lifting_Appliances_Guide_e-Aug14_2.pdf PDF
HB-561_(FRV40-225-128-010)_Steering_Gear.pdf PDF
HB_FY16_Dry_Dock_Spec_(08-26-15).pdf PDF
Amendment_0001.pdf PDF
ADCP_Ocean_Surveyor_-_Shipboard_Installlation_Guide.pdf PDF
HB-461_FE93_Transducer_Arrangement_and_Installation.pdf PDF
ADCP_tank_detalied_drawing_124068_Revision_A.pdf PDF
ADCP_150_kHz_Ocean_Surveyor_Transducer_outline_drawing.pdf PDF
HB-244_02_(FRV40-225-005-010)_Bearings _Lineshaft_and_Thrust_Model_SKF_and_Michell_Bearings_(pages_01_-_50).pdf PDF
HB-593_02_(FRV40-225-059-010)_Marine_Sanitation_Device_((MSD)_Model_MX-5_(pages_01_-_100).pdf PDF
thumb.png PNG image
HB-568_(FRV40-225-008-010)_Bow_Thruster_(pages_376_-_425).pdf PDF
SKF_C_3184_KM_Bearing_Dismounting.pdf PDF
(071)Rudder.pdf PDF
Consilium_Model_SAL_R1a_Doppler_Speed_Log_Installation_Manual_(Pages_197_-_204)-2.pdf PDF
HB-568_(FRV40-225-008-010)_Bow_Thruster_(pages_76_-_150).pdf PDF
HB-568_(FRV40-225-008-010)_Bow_Thruster_(pages_226_-_300).pdf PDF
HB-244_01_(FRV40-225-006-010)_SternTube_Bearing_and_Shaft_Seal_(pages_41_-_50).pdf PDF
HB-244_02_(FRV40-225-005-010)_Bearings _Lineshaft_and_Thrust _Model_SKF_and_Michell_Bearing_(pages_76_-_106).pdf PDF
PPI_NBR_63421-006H_(Rev_04).pdf PDF
HB-244_01_(FRV40-225-006-010)_Stern_Tube_Bearing_and_Shaft_Seal_(pages_1-20).pdf PDF
Lifting_Appliances_Guide_e-Aug14_2.pdf PDF
Navy_MIL-D-3134J _Deck_Covering_Materials.pdf PDF
HB-568_(FRV40-225-008-010)_Bow_Thruster_(pages_426_-_478).pdf PDF
NAVSEA_Standard_Item_009-32_FY10-CH1.pdf PDF
HB-568_(FRV40-225-008-010)_Bow_Thruster_(pages_201_-_225).pdf PDF
HB-568_(FRV40-225-008-010)_Bow_Thruster_(pages_01_-_75).pdf PDF
HB-243_(FRV40-225-099-010)_Marine_Shaft_Braking_System.pdf PDF
HB-633_(FRV40-225-011-010)_Cathodic_Protection_System _Marimpress.pdf PDF
HB-244_01_(FRV40-225-006-010)_SternTube_Bearing_and_Shaft_Seal_(pages_51_-_64).pdf PDF
HB-568_(FRV40-225-008-010)_Bow_Thruster_(pages_301_-_375).pdf PDF
HB-593_02_(FRV40-225-059-010)_Marine_Sanitation_Device_((MSD)_Model_MX-5_(pages_101_-_200).pdf PDF
HB-244_02_(FRV40-225-005-010)_Bearings _Lineshaft_and_Thrust _Model_SKF_and_Michell_Bearing_(pages_51_-_75).pdf PDF
Naval_Ships'_Technical_Manual_081 _Waterborne_Underwater_Hull_Cleaning_of_Navy_Ships.pdf PDF
SKF_Instruction_No._81489_OKC_Coupling.pdf PDF
HB-244_01_(FRV40-225-006-010)_Stern_Tube_Bearing_and_Shaft_Seal_(pages_21_-_40).pdf PDF
HB-593_02_(FRV40-225-059-010)_Marine_Sanitation_Device_((MSD)_Model_MX-5-2_(pages_201_-_397).pdf PDF
NAVSEA_Dwg_803_2145532B_Liquid_Level_Indicator_System_(16_sheets).pdf PDF
HB-624_FE70_Impressed_Current_Cathodic_Protection_Arr_DET_Mod.pdf PDF
HB-259-001____Engine _Exhaust _Resilient_Mounts_and_Extension_Struct_Mods_84112880_83075567.pdf PDF
HB-163_FP19_Seachest_Diagram.pdf PDF
Sperry_SRD-500_Doppler_Speed_log_block_diagram.pdf PDF
Show 40 more

Latest 50 of 85 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

çConsilium SAL R1a Manual Art No. 703810

Doc ID:703826A3, SAL R1a Section D Accessories.doc 5 (25)

1 SDP, AC/DC POWER SUPPLY FOR SD DISPLAYS

Part number: 701219

Mechanical specification Height: 45 mm Width: 115 mm Depth: 108 mm Weight: 0.5 kg

Electrical specification Input voltage: 48/115/230 VAC Current capacity (max. load): 230 VAC, 2 pcs SD4

48 or 115 VAC, 1 pc SD4 Output voltage: Approx. 18 VDC

Environmental specification Enclosure material: Aluminium Enclosure protection: IP20, protected (indoor environment) Colour: Black Recommended operating temperature:

0° to +40°C

Operating humidity: Less than 93 % RH (non condensing) at 40°C

If the SD4 displays are not powered from the R1a ELC or (optionally LPU2), they can be powered from a local DC-power source on the bridge or by an SDP.

The SDP can power two SD displays in 230 VAC mode, but only one in 115 or 48 VAC modes.

Doc ID:703826A3, SAL R1a Section D Accessories.doc 6 (25)

Dimension drawings for the SDP can be found in the Appendix section.

Doc ID:703826A3, SAL R1a Section D Accessories.doc 7 (25)

2 SD4 BMB, BULKHEAD MOUNTING BOX

Part number: 704080

Mechanical specification Height: 144 mm Width: 144 mm Depth: 54 mm Weight: 0.9kg

Enclosure protection: IP66, exposed Colour: Black

An SD4 display can be mounted directly on an indoor or outdoor bulkhead by using a BMB (Bulkhead Mounting Box). Using supplied screws, nylon washers and properly tighten the cable gland will make the assembly watertight.

M5x30(x4)

M5(x4)

Ø6,6mm

Doc ID:703826A3, SAL R1a Section D Accessories.doc 8 (25)

3 SD4SA, STAND ALONE MOUNTING BOX

Part number: 704090

Mechanical specification Height: 171 mm Width: 200 mm Depth: 67 mm Weight: 1.2 kg

Enclosure protection: IP66, exposed

40 60

Ø5.5(x4)

Doc ID:703826A3, SAL R1a Section D Accessories.doc 9 (25)

4 SD4EB, EXTENSION BOARD

Part number: 704110

Mechanical specification Height: 30.5 mm Width: 66.0 mm Depth when mounted on SD4: Adds 14 mm (Total when mounted 49 mm) Weight: 0.03 kg

Relay outputs: 2 potential free NO contacts Max load: 30 V/30 mA or 15 V/100 mA for each out-put

Enclosure protection: IP66 when mounted in BMB or SA Operating temperature: 0°C to +40° C

The SD4EB is equipped with two relays, which can be used to obtain 200 p/NM speed pulses or for other users in a specific installation.

Refer to SD4 menu LP6 to verify/initiate desired function of the output, see Section C Installation under headlines “Menu Mode” and “Menu function summary” as described for SD4-3.

Installation The SD4EB is installed directly on the back of the SD4 display. Unplug the 10-pole connector from the SD4, plug in the SD4EB (P01) replacing the 10-pole connector and instead plug in the 10-pole connector in the mating connector on top of the SD4EB. The two relay contacts can now be utilised via terminals #1-4 on the SD4EB.

SD4EB Note Terminal 1 Terminal 2

Relay 1 normally open

Terminal 3 Terminal 4

Relay 2 normally open

Doc ID:703826A3, SAL R1a Section D Accessories.doc 10 (25)

13X01 X02

31 2 4

P01 31

P03

P02

Doc ID:703826A3, SAL R1a Section D Accessories.doc 11 (25)

5 SD4ED, EXTERNAL DIMMER SWITCH

Part number: 704120 Mechanical specification Height: 144 mm Width: 48 mm Depth: 26+28.5 mm Weight: 0.2 kg

Two-way switch Two-way toggle switch

Enclosure protection: IP20, protected (indoor mounting)

The SD4ED is used to DIM an SD4 display from a remote position.

Refer to SD4 menu LP5 to verify/initiate desired function, see Section C Installation under headlines “Menu Mode” and “Menu function summary” as described for SD4- 3.Additional SD4 displays can be connected to the same dimmer switch provided they are powered from the same source. All connected displays will be dimmed but the brightness level on individual displays will not be similar. It is therefore recommended to use serial Remote DIM message when two or more displays shall be dimmed to the same brightness.

Doc ID:703826A3, SAL R1a Section D Accessories.doc 12 (25)

5.1 Installation

SD4 SD4ED Function Terminal 7 Terminal 1 Dim down Terminal 8 Terminal 3 Dim up Terminal 9 Terminal 2 0 VDC

U/N 704120 é Consilium

SD4 DIMMER

30DIM

15.5

I -

II 0V

III +

Doc ID:703826A3, SAL R1a Section D Accessories.doc 13 (25)

6 SD4 SDR2, REMOTE CONTROL PANEL

Part number: 704130

Mechanical specification Height: 48 mm Width: 144 mm Depth: 30 mm Weight: 0.12 kg Colour: Front, background: Satin black (NCS 9000-N) Enclosure material: Front plate: Aluminium. Front foil: Polyester.

Input voltage: 10-32 VDC, (connected to SD4)

Enclosure protection: IP66, panel mounted on a flat surface Operating temperature: 0°C to +40° C

The SDR2 is used to access and operate an SD4 display from a remote position.

Refer to SD4 menu LP5 to verify/initiate desired function, see Section C Installation under headlines “Menu Mode” and “Menu function summary” as described for SD4- 3.

Note: Menu system, e.g. for setting up the SD4, calibration etc, is not accessible from the SDR2 panel.

SD4 SD4 SDR2 Function Terminal 6 Terminal 1 In 1 Terminal 7 Terminal 2 In 2 Terminal 8 Terminal 3 In 3 Terminal 9 Terminal 5 0 VDC Terminal 10 Terminal 6 10-32 VDC

Doc ID:703826A3, SAL R1a Section D Accessories.doc 14 (25)

Installation

Press 2 sec

DIM

Test é Consilium

Reset TripMode WT Trip/

Total

1 2 3 4 5 6

1 2 3 4 5 6

15.5

Doc ID:703826A3, SAL R1a Section D Accessories.doc 15 (25)

7 NMEA UNITS

7.1 SAL 1N4 NMEA Buffer

Part number 704160

The SAL 1N4 NMEA Buffer is intended to interface /split NMEA serial data output where receiver system loads are high or unknown, or where a failure in one system must prevent other systems from being affected.

The SAL 1N4 has one opto-isolated input feeding four separate differential output drivers.

Installation, setup The unit should be bolted to a flat surface, preferably vertically and with wiring from below.

Wiring termination On the lower part of the unit an area is provided for securing the cables using wire straps.

Connection should be done using shielded cable and making sure the installation will be compliant with the EMC requirements of IEC 60945 it is necessary to make sure that the outer cable shield is securely connected to the chassis if the unit.

The simplest way to accomplish this is to remove the outer insulation of the cable and to fold down the screen on the outside of the insulation and to secure the cable with the straps supplied.

Input connection When connected to an output, the yellow input LED should light when the digital input goes active. With a normally working NMEA connection, this LED will flash as data are received and will be unlit between messages.

If the opposite indication is observed, the input terminals “A” and “B” should be reversed.

Output connection The unit has four RS422/485 based output pairs. Each output will drive several NMEA 0183/IEC 61162-1/-2-compliant inputs. The output drivers are not galvanically isolated from the power source, but the NMEA 0183/IEC 61162-1/-2 standard requires all inputs to be opto-isolated.

Output terminal “A” should be connected to input terminal “A” of the receiving equipment, which in some cases is marked “+”. “B” connects in the same way to “B” (or “-“).

Doc ID:703826A3, SAL R1a Section D Accessories.doc 16 (25)

It is in most cases possible to feed also RS232 inputs if this is required. To avoid feeding signal current into the RS232 signal ground, the NMEA output terminal “A” should be connected to RS232 Rx terminal, while the NMEA output terminal “C” should be connected to signal ground of the RS232 input.

Specifications Indications Green LED indicates DC power applied.

Yellow LED NMEA input, flashes when messages are received.

Input Opto coupler input, compliant with NMEA 0183 and IEC 61162-1, voltage range approx 2 - 12 V.

Output NMEA0183/IEC 61162-1 compliant using RS422/485-compatible differential drivers

Power requirements 10 – 40 VDC, less than 10 mA at 24 V (typically 6 mA) with open outputs.

Dimensions Boxed 68,5 x 111 x 22 mm.

Connectors Phoenix screw terminals, accepting up to

1.5 mm² cable.

Environmental Meets or exceeds IEC 60945 class “Protected”

Doc ID:703826A3, SAL R1a Section D Accessories.doc 17 (25)

7.2 SAL N2P NMEA to Pulse Converter

Part number 704161

The SAL N2P / NMEA / Pulse Converter is intended to interface receiver systems requiring input in 200 pulses/nautical mile format.

The SAL N2P uses NMEA contained speed information and also some speed log status information. It has two closing contact relays and two opto coupler outputs.

Input connection

When a serial NMEA input is connected, the yellow input LED should light when the input goes active. With a normally working NMEA connection, this LED will flash as data are received and will be unlit between messages.

Installation, setup The unit should be bolted to a flat surface, preferably vertically and with wiring from below.

Wiring termination On the lower part of the unit an area is provided for securing the cables using wire straps. Connection should be done using shielded cable and making sure the installation will be compliant with the EMC requirements of IEC 60945 it is necessary to make sure that the outer cable shield is securely connected to the chassis if the unit.

The simplest way to accomplish this is to remove the outer insulation of the cable and to fold down the screen on the outside of the insulation and to secure the cable with the straps supplied.

Input connection When connected to an output, the yellow input LED should light when the digital input goes active. With a normally working NMEA connection, this LED will flash as data are received and will be unlit between messages. If the opposite indication is observed, the input terminals “A” and “B” should be reversed.

Output connection The unit has two closing contact relays and two opto couplers. All four of these outputs are galvanic ally separated and need to be fed with an externally provided current.

Doc ID:703826A3, SAL R1a Section D Accessories.doc 18 (25)

Configuration The unit can be used in two distinct modes. Select mode and Auto mode

The Select mode (jumper setting according to the table below), shall always be used to decode incoming NMEA VHW-messages s. 0 = open jumper, 1 = closed jumper, seem from front of units, wire terminations at bottom.

Jumpers Speed source Relay 1 Relay 2 Opto 1 Opto 2

0001 VHW only X X X X

Specifications Indications Green LED indicates DC power applied.

Yellow LED, NMEA input, flashes when messages are received.

Yellow LED, pulse output, reflects active output status.

Input Opto coupler input, compliant with NMEA 0183 and IEC 61162-1, voltage range approx 2 - 12 V.

Relay outputs Two closing contact relays.

Opto coupler output Two opto couplers, current must be provided by load.

Power requirements 10 – 40 VDC, less than 10 mA at 24 V (max 40 mA at 20

VDC)

Dimensions Boxed 68,5 x 111 x 22 mm.

Connectors Phoenix screw terminals, accepting up to

1.5 mm² cable.

Environmental Meets or exceeds IEC 60945 class “Protected”

Doc ID:703826A3, SAL R1a Section D Accessories.doc 19 (25)

Dimensions

Doc ID:703826A3, SAL R1a Section D Accessories.doc 20 (25)

8 SD4-4, GENERAL INSTRUMENT

Part number: 704044

Mechanical specification Height: 144 mm Width: 144 mm Depth: 16 mm Weight: 0.6 kg Enclosure material: Housing: Aluminium. Front foil: Polyester Colour: Housing: black

Front, background: Satin black (NCS 9000-N)

Electrical specification Input voltage: 10-32 VDC (12 or 24 VDC nominal) Current: Maximum 200 mA at 15VDC Serial input: IEC 61162-1 / NMEA0183 Remote inputs: 3 inputs with internal pull-up to +5V, activated by grounding to 0 V Serial output: IEC61162-1 / NMEA0183. Serial driver RS

422/485; max load 100 ohm (10 SD-displays) SW controlled DC (pulse) output +5 V with 35 mA current capacity

Enclosure protection: IP66 in SD4-BMB box or panel mounted on a flat surface Environmental: IEC 60945, exposed class Heat dissipation (max) = Power consumption Operating temperature: -25°C to +55° C

The “mode” window can display selected information, e.g. distance counters, speed, etc., depending on which modes are enabled in the instrument set-up.

Refer to Section C Installation under headlines “Menu Mode” and “Menu function summary” as described for SD4-3.

Doc ID:703826A3, SAL R1a Section D Accessories.doc 21 (25) é Consilium

Mode - +

Esc Menu Enter

SAL

SD4-4

Test

DIM

U/N 704044

704074 S D

4-4 Label

(12 or 24 VDC nominal)

NMEA A in NMEA B in NMEA A out NMEA B out Pulse output

SDR2

SDR2 / Ext Dim - SDR2 / Ext Dim +

0 VDC

10..32 VDC10

Doc ID:703826A3, SAL R1a Section D Accessories.doc 22 (25)

9 SIA-2-8, ANALOGUE SPEED INDICATOR

Part number 71-21049-17

Mechanical specification Height: 144 mm Width: 144 mm Depth: 79 mm Weight: 0.6 kg

Input voltage: 15-48V AC/DC for backlight Analogue input: 0.1 V/knots max 1 mA

Enclosure material: Sheet plate, phenoplast Enclosure protection: Not specified Colour: Black Operating temperature: 0° to +40C Operating Humidity: Less than 93 % RH (non condensing) at 40°C

Doc ID:703826A3, SAL R1a Section D Accessories.doc 23 (25)

9.1 Mechanical Installation

Selecting location

The display shall be panel mounted in an indoor climate.

The display unit is not splash proof or weather proof.

The overall dimensions and mounting details for the SIA-2-8 unit are given in the figure below:

Doc ID:703826A3, SAL R1a Section D Accessories.doc 24 (25)

10 DIMMER POTENTIOMETER FOR SIA-2-8

Part number 71-71091-00

Mechanical specification Height: Refer to drawing Depth: 73 mm Weight: 0.1 kg

Input voltage: 15-48V AC/DC for backlight

Enclosure protection: Not specified Operating temperature: 0° to +40C Operating Humidity: Less than 93 % RH (non condensing) at 40°C

10.1 Electrical installation

Consider the ship's specific wiring diagram, depending on what units are included in the complete scope of supply.

A cable with a single twisted, stranded pair with a common screen shall be used to connect the analogue display to the analogue output terminals of the LDU (#29-30/31-

32) or the ELC (#18-19). Note the polarity.

The SIA-2-8 cannot be dimmed from an SD4 display but must be provided with a separately dimmed 15-48 V AC or DC backlight power. The backlight power can be taken from the R1a ELC or LDU.

Doc ID:703826A3, SAL R1a Section D Accessories.doc 25 (25) çConsilium LPU2 Art No. 704531B6

1 (50)

LPU2

Technical Manual Incl. installation, setting up and maintenance guidelines

Document No. 704531 é C o n s il iu m

2 (50)

Revisions 2006-09-14 A0 RB Created 2007-09-18 B0 RB Document changed from Technical manual to Manual outline 2008-02-12 B1 RB Changed back to Technical Manual. First sharp edition.

2008-02-15 B2 AF Menu_O: BTR, relay+opto out MAIN and REDUN.

2008-07-01 B3 AF T- menues, Distances TRU2, Error codes in Alert-menus. System types – menu S1. GPS. System test. Opto Inputs.

2008-10-08 B4 AF Opto input functions not implemented. Service clarified. RS232 clarified.

2009-06-16 B5 OM SW ver 704580A4. Deleted filters “be edited”, No 38400 Baud NMEA out 2-

23, USB FILL UP=default, IEC62288 SOG STW, Web-interface, CHECKSUM- CORR->CHECKSUMTEST, Dip 1-6 defaults, K1-K4 no pulse, Logic for relay WT- BT- DEPTH INVALID, LED code, Troubleshooting, Alert list updated.

2009-11-16 B6 RB Added tolerances to mechanical installation picture.

3 (50)

Contents 1 Introduction

1.1 General

1.2 Principle of operation

1.3 Block Diagram

2 Technical Specification 3 Mechanical installation

3.1 Dimensions

3.2 Cabinet location

3.3 Cable inlet with EMC protection and cable support

3.4 Grounding bolt

4 Electrical installation

4.1 General

4.2 Cabinet interior

4.3 List of connections

4.4 LPU2 Table of connections by numbers – summary

5 Setting up procedure

5.1 Accessing the LPU2 Menu system

5.2 LPU2 Menus

5.3 Menu system via Web interface

5.4 Menu function summary

6 NMEA filtering 7 Testing Procedure 8 Service and maintenance

8.1 Supervision and alert numbers

8.2 Service modes

8.3 Performing updating sequence

8.4 Performing factory reset

8.5 USB

8.6 Troubleshooting

Annex 1 9 Web-interface

9.1 Start window

9.2 Menu A window

9.3 Display NMEA pop-up window

Annex 2 10 Definitions and abbreviations Annex 3 11 Wiring principles

4 (50)

1 Introduction

1.1 General

This document describes the LPU2 (2nd generation Log Processing Unit), which serves as an interconnection device between SAL speed logs, indicators and other users, such as ARPA, auto-pilots etc.

IEC61162/NMEA serial signals and how to connect cables carrying IEC61162-signals is described in document 700164

1.2 Principle of operation

The LPU2 distributes data between connected units (instruments etc.) in the SAL speed log system, as well as it transmits speed and depth data to external systems. Serial speed/depth data from one or more speed logs is received by the LPU2 and decoded to generate serial data as well as speed pulse signals. A large number of output connections are programmable.

However, a default configuration is active on delivery and shall be used whenever possible.

The unit is equipped with a power supply, able to provide power to SD indicators as well as to an Echo Sounder Display.

The LPU2 is also used for docking log calculations. The output from a Rate Of Turn gyro can be connected to the LPU2 via serial (NMEA) or analogue input. From this input and the received speed/depth signals from the speed log, the LPU2 calculates transversal speeds of both ends of the ship, which can be fed to SD4-5 docking-log indicators.

The SD4 Log Remote Control is used to access the menu system in the LPU2 as well as in connected speed logs. This SD4 shall be labeled as a Speed Log Master Display according to instructions in the SD4 chapter.

The LPU2 is equipped with an Ethernet connection (RJ45) to access the LPU2 web-interface.

This web-interface can be used to access the LPU2 menu system, display in/out going NMEA messages, display alert lists, and for other service purposes.

The LPU2 software is contained in Flash-memory, which can be updated on board from a USB memory stick or using the serial D-sub.

Note 1: The SAL T1 or T2s system does not calculate transversal speed over ground and will therefore not be used in docking log systems.

Note 2: When the LPU2 is used together with a SAL R1a (speed trough water log system), please disregard from all information referring to BT/SOG, transverse speed or docking log functionality.

5 (50)

1.3 Block Diagram

ROT-gyro In docking-log Systems only

SAL T-series or SAL R1a speed log (1 NMEA out)

SAL Transducer with 30m cable

Log processing unit (LPU2) Unit number:704500

• 4 change over contacts

• 4 closing contacts

• 8 opto couplers

• 2 analog outputs

• 23 NMEA 0183 outputs for indicators and other NMEA listeners

• 9 power outputs for indicators, 12-28 VDC

• 24V DC outputs for ESD, ROT-gyro etc

• 9 NMEA 0183 inputs from speed log, SD4 main indicators and other NMEA talkers

• 4 Opto inputs for control signals

• 1 RS 232 port for older ESD / MFD

Intake AC Power

NMEA0183 data

Analog (option) Echo Sounder Display

(ESD2)

In T3/T1 systems only

Digital indicator SD4-2 W T/BT display

NMEA/RS 422

NMEA0183 data

NMEA/RS 422

DC Power

DC Power

Digital indicator SD4-5 Docking log display

NMEA0183 data

DC Power

Digital indicator SD4 Speed Log Master Display Log Remote Control

NMEA0183 data

DC Power

NMEA 0183

Analogue Speed Indicator SIA-2-8

Ana.out 0.1V/knot

DC Power

NMEA Consumer NMEA0183 data

200p/NM Consumer 200p/NM

NMEA0183 data out

NMEA 0183

NMEA0183 redundant

Digital indicator SD1/2 Older generation

NMEA0183 data

DC Power

Mandatory connections in SAL T1/T3 combined speed log & echosounder systems

Redundant Power

This block diagram shows the general layout of the system. Data is received from the SAL T-series speed log and the Rate Of Turn gyro, alternatively a SAL R1a speed log can be used if only speed through water is required. Processing is done in the LPU2, which also serves as data distribution/interfacing unit. The exact wiring depends on each installation, depending on which displays are needed, what turn-rate gyro is used etc.

6 (50)

2 Technical Specification

Mechanical specification Height: 500 mm + 60 mm under the cabinet for cable glands Width: 500 mm Depth: 211.5 mm Weight: 19.7 kg

Power intake: 1 110–115 VAC / 220–230 VAC +/-10% 50-60 Hz Power consumption:

150 VA Maximum, typically 15 VA with 3 pcs SD4 connected or typically 50 VA with a ESD2 and 3 pcs SD4 connected

SD indicator power output terminals:

9 12..28 VDC-outputs distributed over three fuses:

3 x 1A. Maximum total output load 3A

ESD power output: 1 18..32 VDC outputs distributed over one fuse. 1+2 spare terminals Maximum total output load: 1.5A

Serial inputs: 9 Standard IEC61162-1 / NMEA0183 Analogue inputs: 1 +/-10 V Opto inputs: 4 Digital inputs that can detect a voltage above

3.5 V, maximum voltage 40 VDC

Serial output terminals:

23 IEC61162-1 / NMEA0183, totally 13 drivers (Divided into 8 channels)

Serial terminal: 1 RS232 For older generation ESD, in/out Analogue outputs: 2 +/-5VDC, max load 10 mA Switching relay outputs:

4 Switching: 30VDC / 1A Note! Not intended for distance pulses.

Closing relay outputs:

4 Closing: 50VDC / 0.5A 30V/30mA or 15V/100mA recommended max load when used as distance pulse relays.

Opto outputs: 8 5 to 40 VDC, max 50 mA Ethernet connection

1 RJ45, DHCP server.

To access the LPU2 the web-interface, service purpose / setting up

USB Device 1 The USB Device slot is not used.

USB Host 2 Only the lower USB Host 1 slot is used Service D-sub 1 RS232 for service purpose; terminal, Winflash.

Enclosure material: Steel plate Enclosure protection: IP22, splash proof EMC: IEC 60945, protected class Heat dissipation (max) = Power consumption Colour: RAL 7035 Recommended operating temperature

0°C to +40° C

Extreme operating temperature: -15°C to +55° C Extreme operating Humidity: Less than 93 % RH (non condensing) at 40°C

7 (50)

3 Mechanical installation

The LPU2 is mounted in an IP22 drip-proof cabinet. All cables are brought into the case via cable glands in the bottom plate. Steel bolts in the dimension M8 shall be used for mounting. To assure that the cabinet is drip-proof, nylon washers must be used to seal the fixing holes.

3.1 Dimensions

LPU2 ELC: 500 x 500 x 212mm (H x W x D) + 60 mm under the LPU2 for cable gland.

NOTE: When mounting, reserve a space of at least 150 mm under the cabinet for cable routing.

3.2 Cabinet location

• The LPU2 cabinet shall be vertically mounted in a location where necessary cabling from bridge equipment can be brought to the unit, preferably on the bridge or a space close to the bridge.

• The location must have space enough to give sufficient space and accessibility for service of the unit.

• The location shall be protected from weather and shall offer a stable temperature.

• The location shall not expose the unit to excessive vibration levels.

• The location shall be far from electrical installations giving excessive electric and/or magnetic fields.

• The cabinet bottom shall be placed approximately 1.2 m from the floor where practical.

• Compass safe distance 2 meters.

8 (50)

3.3 Cable inlet with EMC protection and cable support

18 pieces EMC protected tubes with inside diameter 20mm are mounted on the bottom plate.

More than one cable can be routed through each tube. On the inside of the cabinet each tube is equipped with a clamp plate for fixation of the cable screen. Cable support is provided by tighten a cable tie (zip tie), in the slit on the bottom of the tube, round the cable and the tube.

3.4 Grounding bolt

The bottom plate is equipped with a grounding bolt, which shall be connected to the metal structure of the ships hull. The cable area of this connection shall be at least10mm2, preferably using copper braid.

4 Electrical installation

4.1 General

To simplify the reading of this instruction, IEC61162/NMEA serial signals are named just

NMEA.

Closer information about IEC61162/NMEA serial signals and how to connect cables carrying IEC61162.signals is described in document 700164.

Also see Appendix 2 (Wiring Principles) below.

All cables shall be brought into the case via the provided cable inlet tubes in the bottom plate and all screens shall be properly terminated in the inlet tube clamp plate.

The cable screens between the SAL Speed log ELC and the LPU2 should only be connected to the LPU2 and not to the SAL ELC. Use a shielded cable with twisted pairs to connect the SAL Speed Log ELC to the LPU2.

The connection terminals are positioned on the IO-PCB and the PSU-PCB. Terminals that are stacked on top of each other have the same number with an extra letter or mark, indicating column. For example NMEA in 1 has terminal numbers 1A, 1B and 1C, Opto out 1 has terminal numbers 28+ and 28-.

The terminals are designed for cable areas with a cross-section from 0,5 mm² to maximum 2,5 mm² terminated without end caps.

9 (50)

4.2 Cabinet interior

The transformer and three Printed Circuit Boards are mounted on a plate inside the cabinet. The top PCB (CPU-PCB) is covered with a protection plate, in which holes are made for USB, Ethernet and RS232 connectors as well as the red 2 x LED digits. Also the reset pushbutton and the DIP switches are accessible without removing the front plate. All connection terminals are found on the two uncovered boards (IO- and PSU- PCB).

4.3 List of connections

Main power, 115 or 230 VAC (on PSU-PCB) Term# Function Note

71 230 V AC L1

72 115 V AC (L1 if not 71 is connected) 73 N Neutral L2 74 Protective ground GND

Only one of the terminals 71 or 72 shall be connected. When powered from 230VAC, terminal 71-73-74 shall be used and the transformer connector shall be plugged into the 230 VAC contact.

If powered from 115 VAC, terminal 72-73-74 shall be used and the transformer connector shall be plugged into the 115 VAC contact.

10 (50)

The main fuses are positioned next to the main power terminals.

NOTE: There is no main switch. To switch the LPU2 AC power off, remove the fuses.

Connections to Log 1 ELC Term# Function Note 1A NMEA in 1 Connect to T-Series speed Log NMEA "A" output 1B NMEA in 1 Connect to T-Series speed Log NMEA "B" output 42A NMEA out 7 Connect to Log control NMEA "A" input 42B NMEA out 7 Connect to Log control NMEA "B" input

The NMEA in 1 connects to the NMEA out terminal 108 and 109 on the SAL T-Series speed log ELC.

4.3.1 NOTE! NMEA in 1 is not to be used if Log 1 is a SAL R1a!

NMEA in 1 is supervised by the LPU2: if there is no NMEA the relay K1 will drop.

NMEA out 7 (terminal 42) connects to the NMEA in terminal on the SAL Speed log ELC, SAL T-series and R1a.

Redundancy connections to Log 1 ELC Term# Function Note 5A NMEA in 5 Connect to Log NMEA "A" output (redundancy) 5B NMEA in 5 Connect to Log NMEA "B" output (redundancy)

SAL T-series: NMEA in 5 connects to the redundancy NMEA output (Redundant WT) in Log 1 terminal 120 and 121. This will improve the redundancy of the system. Even if the LPU2 and/or the speed over ground log are malfunctioning, at least speed trough water will still be presented on the redundancy outputs.

SAL R1a: NMEA in 5 connects to the NMEA output on the SAL R1a ELC.

NMEA in 5 is supervised by the LPU2 if there is no NMEA the relay K2 will drop.

Also refer to typical Connection diagrams in the system drawing section.

This connection (Redundant WT) has to be made when a SAL T1 or T3 system is installed to ensure the redundancy between the speed log part and the echo sounder part of the combined SAL T1 / T3 Speed log / Echo sounder system.

Connections to Log 2 ELC (option) Term# Function Note 2A NMEA in 2 Connect to Log NMEA "A" output 2B NMEA in 2 Connect to Log NMEA "B" output 43A NMEA out 8 Connect to Log control NMEA "A" input 43B NMEA out 8 Connect to Log control NMEA "B" input

A second SAL Speed Log can be connected to the LPU2. The NMEA in 2 and NMEA out 8 shall be connected to the NMEA connections of the Log 2 ELC via a twisted pair cable.

Connection to gyro (if docking-log option is used)

11 (50)

3A NMEA in 3 Connect to NMEA "A" output terminal from gyro 3B NMEA in 3 Connect to NMEA "B" output terminal from gyro

Instead of a serial NMEA interface an analogue signal can be used to obtain rate of turn information from the gyro.

Term# Function Note 17 Sign. Analogue in Connect to analogue output signal from gyro 17 0VDC Analogue in Connect to signal ground from gyro Note! The gyro output impedance may not exceed 150Ω when using the analogue input.

Connections to ESD2 In SAL T1, T3 and T3+ systems an ESD2, Echo Sounder Display 2nd, is used to present a graphical view of the depth, handle depth alarms, store historical depth data and such. The ESD2 is connected to the LPU2 over an NMEA / 422 interface.

NMEA interface (1st option for ESD2 connection) and power to ESD Term# Function Note 4A NMEA in 4 Connect to NMEA "A" output from ESD2 (COM4, D9 #2) 4B NMEA in 4 Connect to NMEA "B" output from ESD2 (COM4, D9 #7) 36A NMEA out 1 Connect to NMEA "A" input to ESD2 (COM 4, D9 #8) 36B NMEA out 1 Connect to NMEA "B" input to ESD2 (COM 4, D9 #3) 47+ +18 to 32 VDC Connect to DC power input of ESD with a separate DC power cable.

47- 0 VDC Connect to DC power input of ESD with a separate DC power cable.

The DC power cable shall have a cross section of at least 1.5 mm2

NMEA out 1 will be directly connected, via redundancy relays, to NMEA in 1 (the main input from speed log1) in case of loss of power or a failure in the LPU2.

RS232 interface(2nd option for older ESD connection) Term# Function Note 10 RS232 In (Rx) Connect to pin 3 in 9-pole D-sub on display 11 RS232 GND Connect to pin 5 in 9-pole D-sub on display 12 RS232 Out (Tx) Connect to pin 2 in 9-pole D-sub on display Terminal 12 has same function as NMEA out 1.

Terminal 10 and terminal 4 has same function and can therefore not be used simultaneously.

SD4 Log remote control – Speed Log Master Display and redundancy indicator Term# Function Note 37A NMEA out 2 Connect to SD4 NMEA "A" input 37B NMEA out 2 Connect to SD4 NMEA "B" input 6A NMEA in 6 Connect to SD4 NMEA "A" output 6B NMEA in 6 Connect to SD4 NMEA "B" output 50+ +12 to 28 VDC Connect to DC power input of indicator 50- 0 VDC Connect to DC power input of indicator8

12 (50)

The speed logs and the LPU2 menu system can be remotely accessed for calibration and setup of parameters from an SD4 indicator such as SD4-2.

The NMEA out 2 and NMEA in 6 shall be connected to the NMEA in and out connections of the SD4 via a twisted pair cable. It is recommended to use a shielded cable with four twisted pairs to connect the SD4 to the LPU2, two pairs for NMEA, one pair for power and one pair as spare. NMEA out 2 will be directly connected, via redundancy relays, to NMEA in 5 (the redundancy output of speed log1) in case of loss of power or a failure in the LPU2.

2nd SD4 Log remote control Term# Function Note 44A NMEA out 9 Connect to SD4 NMEA "A" input 44B NMEA out 9 Connect to SD4 NMEA "B" input 7A NMEA in 7 Connect to SD4 NMEA "A" output 7B NMEA in 7 Connect to SD4 NMEA "B" output 51+ +12 to 28 VDC Connect to DC power input of indicator 51 0 VDC Connect to DC power input of indicator

A 2nd SD4 remote control can be connected to the system. It will have the same remote control functionality as the main display.

GPS input Term# Function Note 8A NMEA in 8 Connect to GPS NMEA "A" output 8B NMEA in 8 Connect to GPS NMEA "B" output

GPS info received is only used for diagnostic purpose. This is an optional but recommended connection with the intention to simplify troubleshooting of the speed log system.

Alarm Mute input or 3rd SD4 Log remote control Term# Function Note 9A NMEA in 9 Connect to bridge alarm panel 9B NMEA in 9 Connect to bridge alarm panel NMEA in 9 is used to mute alarms from a central alarm panel on the bridge.

Digital inputs (opto-isolated) Note! Opto functions are not implemented in software release 704580A3 or earlier.

Term# Function Note 13+ OPTO in1 ESD alarm mute 13- OPTO in1 Opto input 1 is used to mute ESD alarms in SAL T1 or T3 systems.

Term# Function Note 14+ OPTO in2 LOG 2 BT silent mode 14- OPTO in2 Opto input 2 is used to stop the acoustic transmission from the BT part of log 2 if applicable.

15+ OPTO in3 Echo sounder 2 MAIN

13 (50)

15- OPTO in3 When activated ES 2 (LOG 2) becomes the active Echo Sounder.

16+ OPTO in4 LOG 2 MAIN 16- OPTO in4 When activated LOG 2 becomes the active log

Input choices:

ALARM MUTE

LOG 2 MAIN

ES 2 MAIN

LOG 1 BT MUTE

LOG 2 BT MUTE

These electrical inputs are galvanic separated from the LPU2 by opto couplers. The OPTO inputs can detect an input voltage above 3,5VDC. Maximum input voltage is 40VDC.

NMEA out 10 – 15, connections to NMEA slave indicators SD4/SD1/SD2 Provisions are made to connect NMEA output and DC power to SD4 or SD1/SD2 slave indicators. In total, including the Log Remote indicators, a maximum of 9 (nine) SD indicators can be powered from the LPU2.

45A NMEA out 10 Connect to SD4 NMEA "A" input 45B NMEA out 10 Connect to SD4 NMEA "B" input 52+ +12 to 28 VDC Connect to DC power input of indicator 52- 0 VDC Connect to DC power input of indicator

Term# Function Note 46A NMEA out 11 Connect to SD4 NMEA "A" input 46B NMEA out 11 Connect to SD4 NMEA "B" input 53+ +12 to 28 VDC Connect to DC power input of indicator 53- 0 VDC Connect to DC power input of indicator

Term# Function Note 59A NMEA out 12 Connect to SD4 NMEA "A" input 59B NMEA out 12 Connect to SD4 NMEA "B" input 54+ +12 to 28 VDC Connect to DC power input of indicator 54- 0 VDC Connect to DC power input of indicator

Term# Function Note 60A NMEA out 13 Connect to SD4 NMEA "A" input 60B NMEA out 13 Connect to SD4 NMEA "B" input 55+ +12 to 28 VDC Connect to DC power input of indicator 55- 0 VDC Connect to DC power input of indicator

14 (50)

61A NMEA out 14 Connect to SD4 NMEA "A" input 61B NMEA out 14 Connect to SD4 NMEA "B" input 56+ +12 to 28 VDC Connect to DC power input of indicator 56- 0 VDC Connect to DC power input of indicator

Term# Function Note 62A NMEA out 15 Connect to SD4 NMEA "A" input 62B NMEA out 15 Connect to SD4 NMEA "B" input 57+ +12 to 28 VDC Connect to DC power input of indicator 57- 0 VDC Connect to DC power input of indicator

The NMEA out A and B shall be connected to the NMEA in connections of the SD indicators via a twisted pair cable. It is recommended to use a shielded cable with two twisted pairs to connect the slave SD indicators to the LPU2, one pair for NMEA and one pair for power.

NMEA out 3 – 6 and 16 – 23, connections to external NMEA listeners 12 external NMEA listeners can be connected to the LPU2. Out 3 – 6 share driver and will be directly connected to NMEA in 5 (the redundancy output of speed log1) in case of loss of power or a failure in the LPU2.

Term# Function Note 38A NMEA out 3 Connect to external NMEA listener, NMEA "A" input 38B NMEA out 3 Connect to external NMEA listener, NMEA "B" input

Term# Function Note 39A NMEA out 4 Connect to external NMEA listener, NMEA "A" input 39B NMEA out 4 Connect to external NMEA listener, NMEA "B" input

Term# Function Note 40A NMEA out 5 Connect to external NMEA listener, NMEA "A" input 40B NMEA out 5 Connect to external NMEA listener, NMEA "B" input

Term# Function Note 41A NMEA out 6 Connect to external NMEA listener, NMEA "A" input 41B NMEA out 6 Connect to external NMEA listener, NMEA "B" input

63A NMEA out 16 Connect to external NMEA listener, NMEA "A" input 63B NMEA out 16 Connect to external NMEA listener, NMEA "B" input

Term# Function Note 64A NMEA out 17 Connect to external NMEA listener, NMEA "A" input 64B NMEA out 17 Connect to external NMEA listener, NMEA "B" input

65A NMEA out 18 Connect to external NMEA listener, NMEA "A" input

15 (50)

65B NMEA out 18 Connect to external NMEA listener, NMEA "B" input

Term# Function Note 66A NMEA out 19 Connect to external NMEA listener, NMEA "A" input 66B NMEA out 19 Connect to external NMEA listener, NMEA "B" input

Term# Function Note 67A NMEA out 20 Connect to external NMEA listener, NMEA "A" input 67B NMEA out 20 Connect to external NMEA listener, NMEA "B" input

Term# Function Note 68A NMEA out 21 Connect to external NMEA listener, NMEA "A" input 68B NMEA out 21 Connect to external NMEA listener, NMEA "B" input

Term# Function Note 69A NMEA out 22 Connect to external NMEA listener, NMEA "A" input 69B NMEA out 22 Connect to external NMEA listener, NMEA "B" input

Term# Function Note 70A NMEA out 23 Connect to external NMEA listener, NMEA "A" input 70B NMEA out 23 Connect to external NMEA listener, NMEA "B" input

Connections to relays and opto coupler outputs There are 16 outputs of this kind: 4 switching relays, 4 closing relays and 8 opto couplers. The function of each relay/opto output can be programmed into the LPU2, using the commands and procedures defined in section 5, "Setting up Procedure".

Note! The switching relays K1-K4 are not intended for distance pulse function. First choice for pulse function is opto O1-O8, second K5-K8. Warranty can not be claimed if K1, K2, K3 or K4 are used for distance pulse function.

Switching relays (NC=normally closed contact, CM=common, NO=normally open contact) Relay# Term# Default signal K1 20:NC 20:CM 20:NO No NMEA Log 1 Main = de-energized K2 21:NC 21:CM 21:NO No NMEA Log 1 Redundancy = de-energized K3 22:NC 22:CM 22:NO WTL Astern = energized K4 23:NC 23:CM 23:NO ESD Alarm = de-energized

When energized, the corresponding LED will be lit and CM-NO will be electrically connected.

The relays K1 and K2 supervise the NMEA in 1 and 5. The relays will be de-energized for no NMEA activity.

Relay K3 will be energised when WTL alter from ahead to astern speed.

16 (50)

Relay K4 will be de-energized when an Echo sounder alarm occurs, or if no SAL ESD is connected to the LPU2. Only valid in SAL T1, T3 and T3+.

Closing relays (NO=normally open contact, CM=common) Relay# Term# Default signal K5 24:CM 24:NO Speed through water longitudinal 200p/nm, WTL K6 25:CM 25:NO Speed through water longitudinal 200p/nm, WTL K7 26:CM 26:NO Speed over ground resulting 200p/nm, BTR K8 27:CM 27:NO Speed over ground resulting 200p/nm, BTR If no transversal bottom track speed (BTT) is available such as in SAL T2s and T1 systems, all BTR outputs will be calculated as if BTT=0, thus BTR outputs will be equal to BTL. This is applicable for analogue out, pulse relays and opto-couplers.

Opto-couplers Opto# Term# Default signal O1 28+ 28- Speed through water longitudinal 200 p/nm, WTL O2 29+ 29- Speed through water longitudinal 200 p/nm, WTL O3 30+ 30- Speed through water longitudinal 200 p/nm, WTL O4 31+ 31- Speed through water longitudinal 200 p/nm, WTL O5 32+ 32- Speed over ground resulting 200 p/nm, BTR O6 33+ 33- Speed over ground resulting 200 p/nm, BTR O7 34+ 34- Speed over ground resulting 200 p/nm, BTR O8 35+ 35- Speed over ground resulting 200 p/nm, BTR

Analogue outputs Output Term# Default signal Ana out 1 18:Sign 18:0VDC Speed through water longitudinal 0.1 V/knot, WTL Ana out 2 19:Sign 19:0VDC Speed over ground resulting 0.1 V/knot, BTR

17 (50)

4.4 LPU2 Table of connections by numbers – summary

4.4.1 Terminals on I/O PCB:

Terminal Name Function Default use 1A In 1 A 1B In 1 B

NMEA in 1 Speed log 1 Main, NOT R1a

1C Not to be used 2A In 2 A 2B In 2 B

NMEA in 2 Speed log 2

2C Not to be used 3A In 3 A 3B In 3 B

NMEA in 3 Gyro (ROT)

3C Not to be used 4A In 4 A 4B In 4 B

NMEA in 4 ESD2

4C Not to be used 5A In 5 A 5B In 5 B

NMEA in 5 Speed log 1 Redundancy/R1a

6A In 6 A 6B In 6 B

NMEA in 6 SD4 Log remote control – Speed Log Master Display

18 (50)

7A In 7 A 7B In 7 B

NMEA in 7 SD4 Log remote control

8A In 8 A 8B In 8 B

NMEA in 8 GPS for diagnostic purpose

9A In 9 A 9B In 9 B

NMEA in 9 Alarm Mute

10 In (Rx) RS232 In

11 GND RS232 GND

12 Out(Tx) RS232 Out

Older Echo Sounder Display (Tx = Channel 0)

13 + 13 -

Opto in1 ESD Alarm mute

14 + 14 -

Opto in2 LOG 1 bottom track mute

15 + 15 -

Opto in3 Echo sounder 2 MAIN

16 + 16 -

Opto in4 LOG 2 MAIN

17 Sign

17 0VDC

Analogue in ROT Gyro (+-10V)

18 Sign

18 0VDC

Ana out 1 Speed through water longitudinal, 0.1V/knot

19 Sign

19 0VDC

Ana out 2 Speed over ground resulting, 0.1V/knot

20 NC Normally Closed 20 CM Common

20 NO

K1 Normally Open

No NMEA Log 1 Main

21 NC Normally Closed 21 CM Common

21 NO

K2 Normally Open

No NMEA Log 1 Redundancy / R1a

22 NC Normally Closed 22 CM Common

22 NO

K3 Normally Open

WTL Astern

23 NC Normally Closed 23 CM Common

23 NO

K4 Normally Open

ESD Alarm

24 CM

24 NO

K5 Speed through water longitudinal 200p/nm

25 CM

25 NO

K6 Speed through water longitudinal 200p/nm

26 CM

26 NO

K7 Speed over ground resulting 200p/nm

27 CM

27 NO

K8 Speed over ground resulting 200p/nm

28 + 28 -

Opto 1 Speed through water longitudinal 200p/nm

29 + 29 -

Opto 2 Speed through water longitudinal 200p/nm

30 + 30 -

Opto 3 Speed through water longitudinal 200p/nm

31 + 31 -

Opto 4 Speed through water longitudinal 200p/nm

32 + Opto 5 Speed over ground resulting 200p/nm

19 (50)

32 - 33 + 33 -

Opto 6 Speed over ground resulting 200p/nm

34 + 34 -

Opto 7 Speed over ground resulting 200p/nm

35 + 35 -

Opto 8 Speed over ground resulting 200p/nm

36 A Out 1 A 36 B Out 1 B

NMEA out 1 (redundancy) ESD2 (Channel 0)

36 C Not to be used 37 A Out 2 A 37 B Out 2 B

NMEA out 2 (redundancy) SD4 Log remote control – Speed Log Master Display (Channel 1)

38 A Out 3 A 38 B Out 3 B

NMEA out 3 (redundancy) (Out 3-6 share driver)

Connects to external NMEA listeners (Channel 2)

39 A Out 4 A 39 B Out 4 B

NMEA out 4 (redundancy) (Out 3-6 share driver)

Connects to external NMEA listeners (Channel 2)

40 A Out 5 A 40 B Out 5 B

NMEA out 5 (redundancy) (Out 3-6 share driver)

Connects to external NMEA listeners (Channel 2)

41 A Out 6 A 41 B Out 6 B

NMEA out 6 (redundancy) (Out 3-6 share driver)

Connects to external NMEA listeners (Channel 2)

42 A Out 7 A 42 B Out 7 B

NMEA out 7 Log 1 (Channel 3)

43 A Out 8 A 43 B Out 8 B

NMEA out 8 Log 2 (Channel 4)

44 A Out 9 A 44 B Out 9 B

NMEA out 9 2nd SD4 Log remote control (Channel 5)

45 A Out 10 A 45 B Out 10 B

NMEA out 10 (Out 10-11 share driver)

SD indicator (Channel 6)

46 A Out 11 A 46 B Out 11 B

NMEA out 11 (Out 10-11 share driver)

SD indicator (Channel 6)

47 + 18-32 VDC

47 -

Power for Echo Sounder Display, ESD

48 + 18-32 VDC

48 -

Spare

49 + 18-32 VDC

49 -

Spare

50 + 12-28 VDC

50 -

Power for SD indicators

51 + 12-28 VDC

51 -

Power for SD indicators

52 + 12-28 VDC

52 -

Power for SD indicators

53 + 12-28 VDC

53 -

Power for SD indicators

54 + 12-28 VDC

54 -

Power for SD indicators

55 + 12-28 VDC

55 -

Power for SD indicators

20 (50)

56 + 12-28 VDC

56 -

Power for SD indicators

57 + 12-28 VDC

57 -

Power for SD indicators

58 + 12-28 VDC

58 -

Power for SD indicators

59 A Out 12 A 59 B Out 12 B

NMEA out 12 (Out 12-13 share driver)

SD indicator (Channel 6)

60 A Out 13 A 60 B Out 13 B

NMEA out 13 (Out 12-13 share driver)

SD indicator (Channel 6)

61 A Out 14 A 61 B Out 14 B

NMEA out 14 (Out 14-15 share driver)

SD indicator (Channel 6)

62 A Out 15 A 62 B Out 15 B

NMEA out 15 (Out 14-15 share driver)

SD indicator (Channel 6)

63 A Out 16 A 63 B Out 16 B

NMEA out 16 (Out 16-17 share driver)

Connects to external NMEA listeners (Channel 7)

64 A Out 17 A 64 B Out 17 B

NMEA out 17 (Out 16-17 share driver)

Connects to external NMEA listeners (Channel 7)

65 A Out 18 A 65 B Out 18 B

NMEA out 18 (Out 18-19 share driver)

Connects to external NMEA listeners (Channel 7)

66 A Out 19 A 66 B Out 19 B

NMEA out 19 (Out 18-19 share driver)

Connects to external NMEA listeners (Channel 7)

67 A Out 20 A 67 B Out 20 B

NMEA out 20 (Out 20-21 share driver)

Connects to external NMEA listeners (Channel 7)

68 A Out 21 A 68 B Out 21 B

NMEA out 21 (Out 20-21 share driver)

Connects to external NMEA listeners (Channel 7)

69 A Out 22 A 69 B Out 22 B

NMEA out 22 (Out 22-23 share driver)

Connects to external NMEA listeners (Channel 7)

70 A Out 23 A 70 B Out 23 B

NMEA out 23 (Out 22-23 share driver)

Connects to external NMEA listeners (Channel 7)

21 (50)

4.4.2 Terminals on PSU PCB:

71 230 VAC 230 VAC Power supply (L1) 72 115 VAC 115 VAC Power supply (L1 Option) 73 N Neutral (L2) 74 GND Ground

5 Setting up procedure The LPU2 has an internal menu system that can be accessed via a remote SD4 Speed Log Master Display or via the web-interface. At setup the menu system is used for:

1) changing the default setup of input- and output channels. See Menu I, N and O.

2) enter speed log transducer (TRU) position to enable docking log calculations. See Menu

S on page 28.

3) enter system type: T-Series, R1a or Dual Log. See Menu S on page 27.

4) access the internal alert list for troubleshooting. See Menu A on page 24.

The settings are stored in non-volatile memory and will therefore also be active after a reboot or power shut-down. After the setting up is finished and the system is tested, no further actions are required during normal operation.

5.1 Accessing the LPU2 Menu system

The LPU2 Menu system is accessed from an SD4 Speed Log Master Display unit or the web-interface. Here follows a short guide to access the menu system in the LPU2 via the Speed Log Master Display. (For a detailed description of the menu system in the SD4 Master Display, see document “704005 SD4 Technical description”.)

5.1.1 Reaching SD4 Menu Mode

The Mode window of the SD4 Display can be set to Menu Mode, which is used for internal settings of the display and can be used to connect to a remote unit such as the LPU2.

22 (50)

The Menu Mode is reached by pressing the Mode button for minimum 5 sec. The Mode Window will show the text “PRESS ENTER FOR MENU”. Then press the “Enter button (4th button from left)” within 5 seconds.

The Mode Window will now show the start menu in the SD4. The six buttons under the Mode Window have now got alternative functions. The alternative functions are lit in red text below relevant button.

The buttons now have the following functions:

Mode: “1st button from left”. Will inform which remote device is connected in remote mode.

Esc: “2nd button from left”. The Escape function is used in the “Remote Device menu” to escape from the menu system in a remotely connected unit (E.g. the LPU2 menu system) and step back to the local menu system in the SD4 unit.

Menu: “3rd button from left”. Is used alone, or together with the Minus (-) button, or together with the Enter button, to move in the menus as described below.

Menu button alone, will display next menu i.e. step forward on same menu level.

Menu button and Minus (-) buttons pressed simultaneously will display previous menu, i.e. step back on the same menu level.

Menu button and Enter buttons pressed simultaneously will move up one menu level, except when leaving the “Remote Device menu”. (see Esc-button)

Enter: “4th button from left” is used to store changed values or to move to sub-menus.

- + “Minus button” and “Plus button” are used to change values or status (E.g. write access OFF/ON) and /or to change device values.

Note: The Menu System will exit automatically if no button has been pressed for 5 minutes when being in the local SD4 Menu System, when connected to a remote device there is no timeout and the Escape button must be used to exit from a remotely connected device.

5.1.2 SD4 in Menu Mode

The Menu Mode in the SD4 has three “Local Menus” and one “Remote Device menu”:

• SD4 LOCAL. This is the start menu when entering the Menu Mode. If one or more other displays are remotely dimmed from the display, this menu shows a second text line were the remote dimming function can easily be turned ON/OFF.

• LP0 PROPERTIES. This menu contains sub menus for local setting up of the display.

Note: Do not turn write access ON without special training.

• LS0 REMOTE SETUP. This menu contains sub menus for setting up when the display is used as a Speed log Master Display /Remote Device for other units and displays.

Note: Do not turn write access ON without special training

• R0 REMOTE DEV. On designated Speed Log Master Displays this menu provides access to a remote device, e.g. the WTU-unit, BTU-unit or the LPU2 menu structure.

Note: Verify that the setting in SD4 menu LS7 is “R0 REMOTE ENABLED [ON]” to be able to connect to remote devices.

To connect to the menu system in the LPU2:

23 (50)

When in SD4 LOCAL (the start menu) step to R0 REMOTE DEV menu by pressing the MENU button three times.

When pressing ENTER in the R0 menu the SD4 will establish communication with all connected equipment and display them in a list of menu choices.

Press the MENU button until the LPU is displayed and press ENTER to start communicating with the LPU2.

ESC is used to step back.

Example of a menu walk in the R0 REMOTE DEV menu:

R0 REMOTE DEV CONNECT

press[Enter]

SYNCHRONISING

(counting down from 5) wait 5 seconds

R1 DEVICE 1 OF 3

BTU 1 (T2A)

press[MENU]

R2 DEVICE 2 OF 3

LPU 1 (LP1)

press[ENTER]

W+XX.X DXXX.X

BL+XX.X T+X.XX

Access to the main menu in the LPU2. Press MENU to go deeper into the LPU2 menu system. To exit back to local mode in the SD4 the ESC button must be used. The ESC button will always step out of the remotely controlled menu system.

MENU+ENTER is used to step back within the remotely controlled menu system.

press[ESC]

R2 DEVICE 2 OF 3

LPU 1 (LP1)

press[ESC or MENU+ENTER]

R0 REMOTE DEV

CONNECT

24 (50)

5.2 LPU2 Menus

The function of each menu in the LPU2 is defined below.

5.2.1 Main Menu

W+XX.X DXXX

BL+XX.X T+X.XX

W+XX.X: Longitudinal water speed, X.XX or XX.X knots. + = ahead, - =astern DXXX: Depth in meters below transducer. XXX or XX.X.

BL+XX.X: Longitudinal ground speed, X.XX or XX.X knots. Sign as above.

T+X.XX: Transversal ground speed, X.XX or XX.X knots. + = starboard, - = port.

This is the "default" menu, which is shown during normal operation. If left in any other menu, the system will return to this menu after 2 minutes of idling.

5.2.2 Menu A, Alert list

When pressing the MENU button in the Main menu, A0 ALERT LIST is displayed.

A0 ALERT LIST

0 ACTIVE 0 ACKN

This menu displays the number of active internal LPU2 alerts (400-499) and external $xxALR NMEA messages if any. Note! $SDALR are not displayed.

Press the ENTER button for sub menu A1. Menu A1 contains a list of active alerts. Use the + button to toggle between all active alerts if any. Use the MENU button to toggle to menu A2.

Menu A2 contains a list of external acknowledged ALR. Use the + button to toggle between all active acknowledged ALR if any.

For a list of LPU2 alert numbers, see Table 6 Alert list on page 40.

5.2.3 Menu I, Inputs

When pressing the MENU button in the Alert list MENU, I0 INPUTS is displayed.

I0 INPUTS

WRITE ACCESS OFF

Settings concerning NMEA- and OPTO- inputs are set under this menu.

NMEA talkers:

I1 NMEA IN1

LOG 1 MAIN

to

I9 NMEA IN9

ALARM MUTE

Which type of NMEA talkers that are connected to the LPU2 can be set in menu I1 to I9. These settings control which type of NMEA messages that will be let through on each input.