DY-BO131-4P_A005_AsbestReport_Bldg.8405.pdf
PDF 13 KB Posted
- Solicitation number
- DY-BO131-4P
About this file
This is an Asbestos Survey: Building Status Report for Building 8405 (Smith Barracks) at installation GE79D. The report documents the asbestos-containing material (ACM) inventory and status within the 2,987 square meter (32,152 square foot) facility, which is utilized for billets, battalion command, staff offices, and company headquarters.
The building contains one identified homogenous area with asbestos-containing material: ceiling tiles (30 x 30 cm, white) totaling 1,000 square meters located throughout the first and second floors of the command headquarters building in all rooms and corridors. Laboratory testing conducted on March 3, 1993, detected no asbestos in three samples (8405-002-A14, 8405-002-AQ4, 8405-002-B14). Five materials have been removed from the building, including vinyl floor tile (1,000 m²), sink top cement board (6 m²), window sills (1 each), sheet gaskets/flanges (40 each), and fire door linings (15 each). The building maintains a "No Asbestos Detected" (NAD) status with a risk score of 60 and urgency level III. Re-surveys are not currently required. The most recent survey was conducted on November 2, 2012, by DPW In-house, with the previous survey dated March 3, 1993, by Baker Environmental. The report emphasizes that contact with the Environmental Division (DSN: 531-3113, CIV: 06111435313113) is required before any work activities commence.
View the file
Other files
Show all 18
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Installation
GE79D - SMITH BARRACKS
Building Number
Building Utilization
Billets /BN CMD/STF OFC/CO H
ASBESTOS SURVEY: BUILDING STATUS REPORT
This report may not be complete. It is vital to contact the Environmental Division before work activities start.
Dieser Bericht ist nicht komplett. Es ist wichtig die Umweltabteilung zu kontaktieren, bevor Arbeiten beginnen.
DSN: 531-3113 CIV:06111435313113
Identified Materials
RECENT RE-SURVEY INFORMATION
Removed Materials
PREVIOUS ASBESTOS SURVEY INFORMATION
Homogenous
Area ID
ACM
Status
Material description Quantity Rating Re-Survey required
8405-002 NAD CEILING TILES, 30 X 30 CM, WHITE 1000 M2 Not required
Building status NAD Recommendation - Next Re-Survey Not required
Building Description / Inaccessible Areas / Narrative
Bldg. Area
32152
Locationm² ft²
Date of Re-Survey
11/2/2012
Re-Surveyed by
DPW In-house 2012
8405-001 R-ACM VINYL FLOOR TILE, 30 X 30 CM, OFF WHITE 1000 M2 NA Not required
8405_ST R-ACM SINK TOP, BLACK/GREY CEMENT BOARD 6 M2 NA Not required
8405_WS R-PACM WINDOW SILLS, GREY 1 EACH NA Not required
8405_SG R-PACM SHEET GASKET, FLANGE, GRAY 40 EACH NA Not required
8405_FD R-PACM FIRE DOOR LINING, GRAY, METAL ENCLOSED 15 EACH NA Not required
Last Survey Date(s) Surveyed by Risk Score Urgency Level
3/3/1993 Baker Env. 1993 60 III
11/2/2012 DPW In-house 2012 III
Homogenous Area Description
CEILING TILES, 30 X 30 CM, WHITE
1ST, 2ND, CO HQ BUILDING, ALL ROOMS AND CORRIDOR
Asbestos Status of HA
NAD
RECENT HA SURVEY INFORMATION
Comments
Homogenous Area Location present:
removed:
Re-Survey required
Not required
O&M
Recommendation
Estimated Quantity
1000 M2
Abatement Status
Condition
Material Friability
NONFRIABLE
Material Type
Disturbance Potential
Activity Level
Accessibility
ASBESTOS SURVEY: HOMOGENOUS AREA (HA) DESCRIPTION and ASSESSMENT
Installation
GE79D - SMITH BARRACKS
Building Number
Homogenous Area
8405-002
Recent Survey Date
3/3/1993
Last Surveyed Surveyed by Previous Risk Score Previous Urgency Level
PREVIOUS HA SURVEY INFORMATION
Laboratory Results
Risk Score / Urgency Level
Sample ID Sampling
Date
Asbestos detected
Laboratory Results in %
8405-002-A14 3/3/1993 NAD No Asbestos Detected
8405-002-AQ4 3/3/1993 NAD No Asbestos Detected
8405-002-B14 3/3/1993 NAD No Asbestos Detected