Text version

BRIDGE INSPECTION REPORT

TURKEY RUN BRIDGE

GWMP OVER TURKEY RUN & PARK ACCESS ROAD

GEORGE WASHINGTON MEMORIAL PARKWAY

LN

STRUCTURE NO. 3300-002P

INSPECTION TYPE: ROUTINE

INSPECTION DATE: 4/13/11

Federal Highway Administration

Report prepared by: WU

MILE POINT:

KILOMETER POINT:

1.34 2.16

Federal Lands Bridge Office Bridge Inspection and Management Program 21400 Ridgetop Circle Sterling, Virginia 20166 http://www.efl.fhwa.dot.gov/FLHBO/BIP

STRUCTURE SUMMARY STRUCTURE NO. 3300-002P

TURKEY RUN BRIDGE INSPECTION DATE: 4/13/11

BRIDGE IDENTIFICATION AND DESCRIPTION

MAIN SPAN MATERIAL: ....... STEEL CONTINUOUS NO. OF MAIN SPANS:

MAIN SPAN TYPE: ............... GIRDER & FLOOR BEAM SYSTEM NO. OF APPR. SPANS:

# OF BEAMS, MAIN SPAN: .. 4 STRUCT. TOTAL LENGTH: .. 405.0 FT (123.4 M)

DECK TYPE: ......................... CONCRETE PRECAST PANELS MAX. SPAN LENGTH: .......... 108.0 FT (32.9 M)

WEARING SURFACE: .......... MODIFIED CONCRETE DECK WIDTH: ...................... 72.8 FT (22.2 M)

ABUT. FOUNDATIONS: ........ SPREAD FTG ON BEARING MAT'L CURB TO CURB WIDTH: ..... 64.8 FT (19.8 M)

PIER FOUNDATION(S): ........ SPREAD FTG ON BEARING MAT'L YEAR BUILT:

ABUTMENT / PIER MAT'L: ... CONCRETE YEAR RECONSTRUCTED: .. 1998

PROJ./PLAN REF. NO: ......... 1A17,1A41,2A / 41901 SKEW ANGLE: ..................... 0 °

NPS ROAD CLASS: .............. 7 - URBAN PARKWAY FRACTURE CRITICAL: ........ YES

STRUCTURE HISTORY: ...... 1983, 2002-STRUCT. STEEL REPAINTED. 1998-DECK REPLACED WITH PRECAST PANELS(NB

& SB). 2004-PRELIM. SCOUR ANALYSIS. 2006-SOME PIER BRGS. MODIFIED.

LOCATION

GEORGE WASHINGTON MEMORIAL PARKWAY MILE POINT: ..................... 1.34 (KM PT 2.16)

STATE: ................................. VIRGINIA LOCATION: 1.4 MILES SOUTH OF I-495.

FACILITY CARRIED: ............ GWMP

FEATURE INTERSECTED: .. TURKEY RUN & PARK ACCESS ROAD

STRUCTURE EVALUATION SUMMARY

This fracture-critical steel girder bridge, which consists of both northbound and southbound structures, is in fair condition overall. The main problems are minor to moderate deterioration of the substructure concrete and the retaining walls which has progressed since the last inspection, widespread minor to moderate cracking and isolated delamination and spalling of the concrete wearing surface, and minor to moderate erosion of the north channel bank at the structure due to stream migration. The substructure and retaining walls should be repaired in order to prevent further concrete deterioration, the wearing surface should be repaired and sealed to halt water intrusion, and the erosion of the north channel bank should be mitigated with the installation of engineered riprap.

Another issue at this time is the reformation of surface rust on the girder and stringer ends at the abutments, which is exacerbated by the leaking expansion joints. These joints should be resealed as necessary, and the girder and stringer ends should be repainted.

Other problems include clogged deck drains and isolated loose stones in the masonry guardwalls. Repairs should be made as outlined in this report to prevent the possible development of more serious or costly problems in the future.

It should be noted that several bearings at the piers have been retrofitted in the past due to a lack of anchor bolts.

Also, the northbound approaches and the right lane of the southbound approaches have been repaved and the lane markings have been repainted since the last inspection.

INSPECTION TEAM: M.D. HARLAN, R.E. ESTES (CLARK NEXSEN)

CONDITION ASSESSMENT:

MATTHEW D. HARLAN, P.E., FIELD TEAM LEADER

REPORT REVIEW:

GARY J. GOODLIN, FIELD TEAM LEADER 703-404-6253

REPORT APPROVAL: DATE: 8/17/11

MARCUS MILLER, P.E., LEAD STRUCTURAL ENGINEER 703-404-6252

RECOMMENDATIONS AND ESTIMATED COSTS STRUCTURE NO. 3300-002P

A (Critical) - Structure is closed, in imminent danger of collapse, or presents a critical safety hazard.

B (Major) - Structure is seriously deficient or presents a safety hazard, but can remain in service at reduced loads or with frequent inspections.

C (Moderate) - Structure is deficient, functionally obsolete, or requires substantial repairs to prevent a serious deficiency or unsafe condition.

D (Minor) - Structure is generally in good condition. Preventative maintenance may be required.

E (Special) - Structure is under construction or reconstruction.

C226 PRIORITY OF IMPROVEMENT

ITEM

NO.

MAINTENANCE RECOMMENDATIONS

(GENERALLY NOT FLHP ELIGIBLE)

QTY. UNIT COST

UNIT

ESTIMATE

COST

PRELIM.

61.2 PROTECT ERODED AREAS OF NORTH CHANNEL BANK AT STRUCTURE WITH

ENGINEERED RIPRAP.

75 CY

59.2,4,7 CLEAN AND PAINT GIRDER AND STRINGER ENDS AT ABUTMENTS. 620 SF

58.3 REPAIR CONCRETE WEARING SURFACE AT SOUTH EXPANSION JOINT OF

NORTHBOUND STRUCTURE AND AT ASPHALT PATCHES.

23 SF

222.3 RESET LOOSE STONES IN MASONRY GUARDWALLS. 1 CY

58.2 CLEAN AND RESEAL EXPANSION JOINTS AS NECESSARY. 17 LF

60.3,13,15, 223.1

REMOVE VEGETATION GROWTH FROM SUBSTRUCTURE AND RETAINING WALL. 1 LS

58.2,7 CLEAN DEBRIS FROM DECK DRAINS AND EXPANSION JOINTS. 1 LS

PRELIM. MAINTENANCE TOTAL :

ITEM

NO.

REHABILITATION/RECONSTRUCTION

(TYPICALLY NEEDED WITHIN 5 YEARS)

QTY. UNIT

UNIT

COST ESTIMATES

PRELIM. COST

REHAB. RECONSTR.

58.3 CLEAN AND SEAL MODIFIED CONCRETE WEARING SURFACE. 22,680 SF

60.1,3,6,13, REMOVE UNSOUND CONCRETE FROM ABUTMENTS, PIERS, AND

RETAINING WALLS, CLEAN REBAR, AND PLACE NEW CONCRETE

TO ORIGINAL DIMENSIONS.

155 SF

222.4,6 REPAVE LEFT LANE IN APPROACHES IMMEDIATELY BEHIND

ABUTMENT BACKWALLS, SOUTHBOUND STRUCTURE.

2 EA

PRELIM. REHABILITATION/RECONSTRUCTION TOTAL :

COST ESTIMATE SUMMARY

PRELIM. MAINTENANCE TOTAL:

PRELIM. REHABILITATION TOTAL: ...

PRELIM. RECONSTRUCTION TOTAL: ..

TOTAL ITEMIZED COSTS:

PRELIMINARY ESTIMATE TOTAL* :

(*Includes typical contract costs for mobilization, traffic control, and design/construction engineering; but does not include detour bridges, work beyond the bridge limits, or work not listed above. Estimates are approximate and are for preliminary planning purposes only; they should not be used as a complete or final engineers estimate.)

REMARKS: Cost estimates assume that the recommended actions will be combined with similar work being performed on other structures.

FIELD INSPECTION REPORT STRUCTURE NO. 3300-002P

CONDITION RATING CODES FOR ITEMS 58 - 62, 222, 223

N NOT APPLICABLE 3 SERIOUS CONDITION - loss of section, deterioration, spalling, or scour have seriously affected primary structural components. Local failures are possible.

9 EXCELLENT CONDITION Fatigue cracks in steel or shear cracks in concrete may be present.

8 VERY GOOD CONDITION - no problems noted. 2 CRITICAL CONDITION - advanced deterioration of primary structural elements. Fatigue cracks in steel or shear cracks in concrete may be present

7 GOOD CONDITION - some minor problems. or scour may have removed substructure support. Unless closely monitored it may be necessary to close the structure until corrective action can be taken.

6 SATISFACTORY CONDITION - structural elements show some minor deterioration. 1 “IMMINENT” FAILURE CONDITION - major deterioration or section loss present in critical structural components or obvious vertical or horizontal

5 FAIR CONDITION - all primary structural elements are sound but may have movement affecting structure stability. Structure is closed to traffic but minor section loss, cracking, spalling, or scour. corrective action may return structure to light service.

4 POOR CONDITION - advanced section loss, deterioration, spalling, or scour. 0 FAILED CONDITION - out of service; beyond corrective action.

CONDITION RATING CODE EQUIVALENTS FOR SUB-ELEMENTS

G = GOOD (CODES 7 - 9) F = FAIR (CODES 5 - 6) P = POOR (CODES 0 - 4)

58. DECK 6 ITEM REFERENCE AND REMARKS

F1. DECK SLAB

F PRECAST CONCRETE DECK PANELS; MINOR SPALLING IN SOME 58.1 2. EXPANSION JOINTS

LOCATIONS ADJACENT TO STEEL DECK PANEL JOINT PLATES. F3. WEARING SURFACE

G MINOR RUSTING OF STEEL DECK PANEL JOINT PLATES DUE TO 4. RIDEABILITY

G5. CURBS, SIDEWALKS, AND MEDIAN WATER PENETRATION THROUGH WEARING SURFACE. GROUT

G6. PARAPETS AND/OR RAILINGS HAUNCHES BETWEEN DECK AND STRINGERS OR GIRDERS

F7. DRAINS AND DRAINAGE INCOMPLETELY POURED IN SEVERAL LOCATIONS WITH

N8. UTILITIES WIDESPREAD SHRINKAGE CRACKING. MINOR VERTICAL CRACKING

G9. DEFLECTION AND/OR VIBRATION WITH EFFLORESCENCE ON SIDES OF OVERHANGS EXTENDING

N10. OTHER INTO CURBS. MINOR LONGITUDINAL CRACKING OF DECK

59. SUPERSTRUCTURE 6 UNDERSIDE AT SOUTH ABUTMENT, BOTH STRUCTURES.

F1. BEARING DEVICES

NORTHBOUND STRUCTURE: MINOR DELAMINATION AND SPALLING F2. GIRDERS OR BEAMS

OF DECK UNDERSIDE AT SOUTH ABUTMENT ADJACENT TO WEST N3. ARCH(ES) OR SLAB(S)

STRINGER. MINOR TO MODERATE SPALL ON DECK UNDERSIDE IN G4. FLOOR BEAMS AND STRINGERS

N CENTER BAY AT FLOOR BEAM #7 AND EAST AND CENTER BAY AT 5. TRUSSES

F FLOOR BEAM #8 IN SPAN #2. 6. DIAPHRAGMS AND BRACING

F7. PAINT

N8. FASCIA(E) SOUTHBOUND STRUCTURE: MINOR DELAMINATION AND SPALLING

G9. DEFLECTION AND/OR VIBRATION OF DECK UNDERSIDE AT NORTH ABUTMENT ADJACENT TO

G10. ALIGNMENT GIRDERS AND STRINGERS. MINOR DELAMINATION OF DECK

N11. OTHER UNDERSIDE AT SOUTH ABUTMENT ADJACENT TO WEST STRINGER.

60. SUBSTRUCTURE 6

MINOR TO MODERATE ACCUMULATION OF DEBRIS IN EXPANSION 58.2

ABUTMENTS

JOINTS, PRIMARILY IN SHOULDERS. ACTIVE LEAKAGE THROUGH

EXPANSION JOINTS AT TIME OF INSPECTION.

NORTHBOUND STRUCTURE: SEAL LOOSE (10'L TOTAL) AT SOUTH

EXPANSION JOINT AND (5'L TOTAL) AT NORTH EXPANSION JOINT

DUE TO MINOR EDGE SPALLING.

SOUTHBOUND STRUCTURE: SEAL LOOSE (1'L) AT SOUTH

EXPANSION JOINT AND (1'L) AT NORTH EXPANSION JOINT DUE TO

MINOR EDGE SPALLING.

BREASTWALLS OR COLUMNS1. F

PILE BENTS2. N

CAPS AND/OR BEARING SEATS3. F

BACKWALLS AND/OR BULKHEADS4. F

FOUNDATIONS5. (BURIED) N

WINGWALLS6. F

WEEP HOLES7. F

EXPANSION JOINTS8. N

EROSION AND/OR SCOUR9. G

SETTLEMENT OR DEFLECTION10. G

SLOPE PROTECTION11. G

OTHER 12. N

PIER(S)

WALLS AND/OR COLUMNS 13. G

PILE BENTS14. N

CAPS AND/OR BEARING SEATS15. F

FOUNDATIONS16. (BURIED) N

EROSION AND/OR SCOUR17. G

SETTLEMENT OR DEFLECTION18. G

OTHER 19. N

ITEM REFERENCE AND REMARKS

STREAM BED COMPOSITION : 9.

AVERAGE CLEAR OPENING 8.

NORMAL VELOCITY 7.

ADEQUACY OF OPENING 6.

OTHER 5.

WATERWAY OBSTRUCTIONS 4.

CHANNEL PROTECTION3.

EROSION AND/OR SCOUR2.

ALIGNMENT1.

61. CHANNEL 6

F F G G N

MED

SUFF

35 FT.

ROCK, SILT

222. APPROACHES 6

OTHER 9.

ALIGNMENT 8.

SIGNS7.

SETTLEMENT 6.

EROSION5.

SURFACING4.

APPROACH GUARDRAIL 3.

2. RELIEF JOINTS

APPROACH SLABS1. N

N G F G F G G N

223. RETAINING WALL 6

OTHER 6.

SETTLEMENT OR DEFLECTION5.

EROSION AND/OR SCOUR4.

FOUNDATION3.

WEEP HOLES2.

1. WALL

(BURIED)

F G N G G N

36. TRAFFIC AND SAFETY FEATURES

APPROACH GUARDRAIL ENDSD.

APPROACH GUARDRAILSC.

TRANSITIONSB.

BRIDGE RAILINGSA. 1

TRAFFIC SAFETY RATING CODES

0 - Does not meet standards or a safety feature is required and none is provided.

1 - Meets currently acceptable standards.

N - Not applicable or a safety feature is not required.

58.3 LATEX MODIFIED CONCRETE WEARING SURFACE; MINOR

TRANSVERSE CRACKING AT JOINTS BETWEEN DECK PANELS,

SOME WITH EFFLORESCENCE. ISOLATED LOCATIONS OF MINOR

LONGITUDINAL CRACKING PROPAGATING FROM TRANSVERSE

CRACKS. LANE MARKINGS RESTRIPED SINCE LAST INSPECTION.

NORTHBOUND STRUCTURE: WIDESPREAD MODERATE MAP

CRACKING OF WEARING SURFACE. MODERATE DELAMINATION

AND SPALLING (15'L X UP TO 1'W X 1-1/2"D) OF WEARING SURFACE

AT SOUTH EXPANSION JOINT; TWO ASPHALT PATCHES HAVE

FAILED (4 SF X 1-1/2"D). ONE ASPHALT PATCH BROKEN UP IN SPAN

#2 NEAR CENTER PIER.

SOUTHBOUND STRUCTURE: WIDESPREAD MINOR MAP CRACKING

OF WEARING SURFACE.

58.5 WIDESPREAD MINOR CRACKING OF CURBS.

NORTHBOUND STRUCTURE: MODERATE SPALL WITH EXPOSED

REBAR ON EAST CURB OVER SOUTH PIER; MINOR DELAMINATION

ADJACENT TO SPALL. MINOR DELAMINATION AND SPALL ON EAST

CURB IN SPAN #2. MINOR DELAMINATION OF EAST CURB IN SPAN

#4.

58.6 MINOR SCRAPES ON RAILS WITH MINOR RUSTING AND PEELING OF

PAINT; MINOR RUSTING OF RAILS AT EXPANSION SLEEVES. RAIL

POST ANCHOR BOLTS UP TO ONE THREAD SHORT OF FLUSH WITH

ANCHOR BOLT NUTS AT ISOLATED LOCATIONS.

SOUTHBOUND STRUCTURE: MOLD GROWTH ON WEST RAILING

NEAR NORTH END.

58.7 MINOR ACCUMULATION OF DEBRIS IN CURBLINES AND

SHOULDERS; CLOGGED DRAINS IN SEVERAL LOCATIONS. LOOSE

AND MISSING ANGLES ON DRAIN EXTENSION SUPPORTS AT

ISOLATED LOCATIONS.

59.1 SEVERAL BEARINGS HAVE BEEN MODIFIED WITH STEEL PLATES TO

STOP ANY MOVEMENT DUE TO LACK OF ANCHOR BOLTS. MINOR

RUSTING OF BEARINGS; UP TO 1/4" PACK RUST BENEATH ROCKERS

PREDATING PAINT. UP TO 1/2" SECTION LOSS TO ANCHOR BOLT

NUTS AT ABUTMENTS PREDATING PAINT.

NORTHBOUND STRUCTURE: TWO ANCHOR BOLTS MISSING FROM

WEST BEARING AND ONE FROM EAST BEARING AT SOUTH PIER.

TWO ANCHOR BOLTS MISSING FROM WEST BEARING AND THREE

FROM EAST BEARING AT CENTER PIER. TWO ANCHOR BOLTS

MISSING FROM EAST BEARING AT NORTH PIER.

SOUTHBOUND STRUCTURE: TWO ANCHOR BOLTS MISSING FROM

WEST BEARING AND TWO FROM EAST BEARING AT SOUTH PIER.

ADDITIONAL ITEM REFERENCE AND REMARKS

59.2,4,6,7 MINOR SECTION LOSS (UP TO 1/8") ON STRUCTURAL STEEL PREDATING PAINT; MINOR SURFACE RUST REFORMING ON GIRDER FIELD SPLICES AT ISOLATED LOCATIONS AND GIRDER AND STRINGER ENDS AT ABUTMENTS. LATERAL BRACING GUSSETS DOWN TO KNIFE EDGE PREDATING PAINT AT ISOLATED LOCATIONS.

NORTHBOUND STRUCTURE: LATERAL BRACING MEMBER DOWN TO KNIFE EDGE WITH AREAS RUSTED THROUGH IN END 3' AT FLOOR BEAM #9 TO EAST GIRDER CONNECTION IN SPAN #2 PREDATING PAINT. MISSING

BOLT IN EAST GIRDER AT FIRST SPLICE FROM SOUTH PIER IN SPAN #2; HOLE MISALIGNED.

SOUTHBOUND STRUCTURE: MINOR PEELING OF PAINT ON UNDERSIDE OF EAST GIRDER BOTTOM FLANGE IN SPAN #4 NEAR NORTH PIER. LATERAL BRACING GUSSET RUSTED THROUGH AT FLOOR BEAM #13 TO EAST GIRDER CONNECTION IN SPAN #3 PREDATING PAINT. BRACING BENT 1" OVER 1' LONG BETWEEN FLOOR BEAMS

#11 AND #12 IN SPAN #3.

60 WIDESPREAD GRAFFITI ON ABUTMENTS AND LOWER PORTIONS OF PIERS.

60.1,3 WIDESPREAD MINOR TO MODERATE CRACKING OF ABUTMENT BREASTWALLS, SOME WITH CHEMICAL STAINS.

MINOR TO MODERATE DELAMINATION AND SPALLING OF BREASTWALLS WITH EXPOSED REBAR. PONDING (UP TO 3"D) ON TOP OF NORTH ABUTMENT BREASTWALLS; MINOR ON TOP OF SOUTH ABUTMENT, NORTHBOUND

STRUCTURE.

NORTHBOUND STRUCTURE: LIGHT ACCUMULATION OF DEBRIS ON TOP OF SOUTH ABUTMENT BREASTWALL.

SOUTHBOUND STRUCTURE: MINOR RANDOM CRACKING AND MODERATE DELAMINATION ON TOP OF SOUTH ABUTMENT BREASTWALL. LIGHT VEGETATION GROWTH ON NORTH ABUTMENT BREASTWALL AT EAST END.

LIGHT ACCUMULATION OF CONCRETE DEBRIS ON TOP OF NORTH ABUTMENT BREASTWALL.

60.4 MINOR VERTICAL CRACKING OF ABUTMENT BACKWALLS, SOME WITH EFFLORESCENCE AND RUST STAINS;

CRACKS EXTEND ACROSS TOP. MINOR EDGE SPALLING ON TOP OF BACKWALLS. MODERATE DELAMINATION OF SOUTH ABUTMENT BACKWALLS WITH EFFLORESCENCE AT ISOLATED LOCATIONS; ACTIVE WATER SEEPAGE

AT SOUTHBOUND STRUCTURE.

SOUTHBOUND STRUCTURE: MINOR DELAMINATION OF NORTH ABUTMENT BACKWALL BEHIND EAST GIRDER.

60.6 MINOR TO MODERATE VERTICAL CRACKING OF WINGWALLS, SOME WITH EFFLORESCENCE AND POPOUTS.

MINOR CRACKING OF WINGWALLS WITH MODERATE TO HEAVY EFFLORESCENCE ALONG TOP. AREAS OF EXPOSED REBAR IN SOUTHWEST WINGWALL DUE TO INSUFFICIENT COVER. MINOR DETERIORATION OF NORTHEAST WINGWALL AT BEARING SEAT WITH RUST STAINING. MODERATE SPALL WITH EMBEDDED TIMBER

IN NORTHEAST WINGWALL.

60.7 MODERATE CORROSION OF WEEP HOLE SLEEVES WITH RUST SCALE.

60.9,11 RIPRAP BENEATH STRUCTURES AT SCUPPER LOCATIONS.

SOUTHBOUND STRUCTURE: MINOR EROSION FILLED WITH RIPRAP NEAR NORTH ABUTMENT BREASTWALL.

60.13,15 MINOR HORIZONTAL CRACKS BENEATH GIRDERS AT ISOLATED LOCATIONS. MINOR TO MODERATE DELAMINATION AND SPALLING OF PIER CAPS AND STEMS WITH EXPOSED REBAR (10% SECTION LOSS), PRIMARILY AT ENDS OF PIER CAPS. MODERATE VEGETATION GROWTH ON CENTER PIERS; VEGETATION

EXTENDS TO EAST BEARING AND ONTO EAST GIRDER, SOUTHBOUND STRUCTURE.

ADDITIONAL ITEM REFERENCE AND REMARKS

61.1,2,3 STREAM HAS MIGRATED TOWARD NORTH PIER CAUSING MODERATE TO SEVERE CHANNEL BANK EROSION.

MODERATE TO SEVERE DETERIORATION OF SILT FENCE ALONG CHANNEL BANKS. SCATTERED RIPRAP IN

CHANNEL AND ON BANKS BENEATH STRUCTURE.

61.4 MINOR ACCUMULATION OF DEBRIS IN CHANNEL AND AGAINST NORTH PIER OF NORTHBOUND STRUCTURE.

222.3 MINOR TO MODERATE DETERIORATION OF MORTAR WITH SEVERAL STONES LOOSE IN GUARDWALLS.

222.4,6 NORTHBOUND STRUCTURE: APPROACHES REPAVED SINCE LAST INSPECTION.

SOUTHBOUND STRUCTURE: RIGHT LANE OF APPROACHES REPAVED SINCE LAST INSPECTION. MINOR TO MODERATE TRANSVERSE AND LONGITUDINAL CRACKING OF APPROACH PAVEMENT IN LEFT LANE. MODERATE SETTLEMENT AND MINOR TO MODERATE DETERIORATION OF APPROACH PAVEMENT ALONG ABUTMENT

BACKWALLS IN LEFT LANE.

222.7 "TURKEY RUN" SIGNS AT WEST SIDE OF NORTH APPROACH AND EAST SIDE OF SOUTH APPROACH.

223.1 MINOR TO MODERATE CRACKING WITH CHEMICAL STAINS, DELAMINATION, AND SPALLING OF CONCRETE RETAINING WALLS WITH EXPOSED REBAR; DETERIORATION OCCURS PRIMARILY ALONG ABUTMENT

BREASTWALLS. VEGETATION GROWTH ON NORTH RETAINING WALL.

36.B,C,D MASONRY APPROACH GUARDWALLS (40" HIGH) IN MEDIAN AND AT EITHER SIDE OF ROADWAY. MASONRY APPROACH GUARDWALLS NOT ATTACHED TO BRIDGE RAILINGS. END TREATMENTS DO NOT MEET CURRENT

AASHTO SPECIFICATIONS.

STRUCTURE LOAD RATING STRUCTURE NO. 3300-002P

TRUCK TYPE

INVENTORY RATING (NORMAL TRAFFIC) OPERATING RATING (MAXIMUM LOAD)

TONS METRIC TONS TONS METRIC TONS

H 24 22 39 35

HS 36 33 60 54

TYPE 3 35 32 58 53

TYPE 3S2 41 37 68 62

TYPE 3-3 44 40 74 67

DESIGN LOADING: HS20 (MS18)

X CAPACITY MEETS OR EXCEEDS DESIGN LOAD

CAPACITY IS LESS THAN DESIGN LOAD

ORIGINAL LOAD RATING CALCULATION APPLICABLE

ORIGINAL LOAD RATING CALCULATION REVISED

DATE OF LOAD RATING CALCULATION:

LOAD RATING CONTROLLED BY:

REMARKS: RATING IS BASED ON DESIGN LOAD OF STRUCTURE.

STRUCTURE INVENTORY AND APPRAISAL STRUCTURE NO. 3300-002P

STRUCTURE IDENTIFICATION

(201) PARK: GEORGE WASHINGTON MEMORIAL PARKWAY (1) STATE: ....................................... 513 - VIRGINIA (VA)

(202) STRUCTURE NAME: .......... TURKEY RUN BRIDGE (2) STATE HWY. AGENCY DIST:

(203) STRUCTURE KIND: ............ 1 - BRIDGE (3) COUNTY CODE: ........................ 059 - FAIRFAX

(204) STRUCTURE NUMBER: ..... 3300-002P (4) CITY/PLACE CODE:

(205) NPS REGION: .................... 2 - NATIONAL CAPITAL (5) INVENTORY ROUTE:

(206) ROUTE CODE NUMBER: ... 1 (6) FEATURES INTERSECTED:....... TURKEY RUN & PARK ACCES

(207) ROAD SECTION NO: .......... 002P (7) FACILITY CARRIED: .................. GWMP

(208) NPS ROAD CLASS: ............ 7 - URBAN PARKWAY (8) STATE STRUCTURE NO: .......... 3300002P0000000

(209) WITHIN NPS BNDRY?: ....... YES (9) LOCATION: ................................ 1.4 MILES SOUTH OF I-495.

(210) OPERATING UNIT: ............. PARK (10) INV. RTE. - MIN. VERT. CLR: .. 99.99 FT (99.99 M)

(211) PROJECT NO(S): ................ 1A17,1A41,2A (11) MILE POINT: ............................. 1.34 (KM PT 2.16)

(212) DRAWING NUMBERS: ....... 41901 (27) YEAR BUILT:

(21) MAINTAINED BY: ................. 66 - NATIONAL PARK SERVICE (106) YEAR RECONSTRUCTED:

(22) OWNER: ............................... 66 - NATIONAL PARK SERVICE (20) TOLL: ........................................ 3 - FREE ROAD

(37) HISTORICAL DESIGNATION: .. 5 - NOT ELIGIBLE

STRUCTURE DESCRIPTION, FOUNDATION, AND DECK TYPE

(43A) MAIN STR. MATERIAL: ..

(43B) MAIN STR. TYPE:

(45) NO. OF MAIN SPANS:

(48) MAX. SPAN LENGTH:

(49) STRUCTURE LENGTH:

(216A) ABUTMENT #1 FDN:

(216B) ABUTMENT #2 FDN:

(217A) PREDOM. PIER FDN.: ..

(217B) SECOND. PIER FDN: ...

(107) DECK TYPE:

4 - STEEL CONTINUOUS

03 - GIRDER & FLOOR BEAM SYSTEM

108.0 FT (32.9 M)

405.0 FT (123.4 M)

2 - SPREAD FTG ON BEARING MAT'L

2 - SPREAD FTG ON BEARING MAT'L

2 - SPREAD FTG ON BEARING MAT'L

2 - SPREAD FTG ON BEARING MAT'L

2 - CONCRETE PRECAST PANELS

(44A) APPR. STR. MATERIAL: ........ 0 - OTHER

(44B) APPR. STR. TYPE: ................ 00 - OTHER

(46) NO. OF APPROACH SPANS: .. 0

(108) WEAR SURFACE/PROTECT SYSTEM:

A) TYPE WEARING SURFACE: .. 3 - MODIFIED CONCRETE

B) TYPE MEMBRANE: ................. 0 - NONE

C) TYPE PROTECTION: .............. 0 - NONE

(218) IS SALT USED?: ..................... YES

LOAD RATING AND POSTING

(31) DESIGN LOAD: ................. 5 - HS20 (MS18) (41) LOAD RESTRICTION: ......... A - OPEN, NO RESTRICTION

(66) INVENTORY RATING: ...... 36.0 TONS (33.0 METRIC TONS) (70) BRIDGE POSTING: .............. 5 - NO POSTING REQUIRED

(64) OPERATING RATING: ...... 60.0 TONS (54.4 METRIC TONS)

INSPECTION DATES

(90) INSPECTION DATE: 4/11 (91) FREQ. OF INSP: 24 MONTHS (92 / 93) CRITICAL FEATURE INSPECTION (CFI):

(219) ADD. STUDIES NEEDED: Y - 5 - SCOUR (A) FRACTURE CRITICAL: ... YES

INSP. EVERY: 24 MONTHS - LAST INSP. : 4/11 (220) SPECIAL STUDY TYPE: 1 - DECK SURVEY

(B) UNDERWATER: .............. NO

(221) SPECIAL STUDY DATE: 6/94 INSP. EVERY: MONTHS - LAST INSP. :

(C) SPECIAL INSPECTION: .. NO

INSP. EVERY: MONTHS - LAST INSP. :

STRUCTURE INVENTORY AND APPRAISAL STRUCTURE NO. 3300-002P

GEOMETRY, TRAFFIC, AND NAVIGATIONAL DATA

(16) LATITUDE: ............................. 38°57'48.60"

(17) LONGITUDE: ......................... 77°09'28.00"

(19) DETOUR LENGTH: ............... 1 MI (2 KM)

(28A) LANES ON STRUCT:

(28B) LANES UNDER STRUCT: ... 02

(42A) SERVICE ON: ..................... 5 - HIGHWAY-PEDESTRIAN

(42B) SERVICE UNDER: .............. 6 - HIGHWAY-WATERWAY

(29) AVG. DAILY TRAFFIC:

(30) YEAR OF ADT:

(114) FUTURE ADT:

(115) YEAR OF FUTURE ADT:

(101) PARALLEL STRUCTURE: ... N - NONE

(38) NAVIGATION CONTROL?: ... 0

(39) VERTICAL CLEARANCE: ...... 0.0 FT (0.0 M)

(40) HORIZ. CLEARANCE: ........... 0.0 FT (0.0 M)

(111) ABUT. OR PIER PROT:

LATERAL UNDERCLEARANCE:

(55) RIGHT: ....................... 5.0 FT (1.5 M)

(56) LEFT: ......................... 0.0 FT (0.0 M)

(51) CURB TO CURB WIDTH: ........... 64.8 FT (19.8 M)

(52) DECK WIDTH: ............................ 72.8 FT (22.2 M)

(32) APPR. ROADWAY WIDTH: ........ 48.0 FT (14.6 M)

(213) APPR. PAVEMENT WIDTH: ..... 48.0 FT (14.6 M)

LEFT SHOULDER: .................. 0.0 FT (0.0 M)

RIGHT SHOULDER: ................ 0.0 FT (0.0 M)

(33) BRIDGE MEDIAN: ....................... 1 - OPEN MEDIAN

(34) SKEW ANGLE: ............................ 0 °

(35) DECK FLARE?: ........................... NO

(47) TOTAL HORIZ. CLEARANCE: .... 32.5 FT (9.9 M)

(50) SIDEWALKS:

LEFT : ...................................... 0.0 FT (0.0 M)

RIGHT : ................................... 0.0 FT (0.0 M)

(214) BRIDGE RAIL TYPE:

RAIL CONFIGURATION: ......... 1 - FULL HEIGHT (NO PARAPE

MATERIAL: .............................. 4 - STEEL

DESIGN TYPE: ........................ 1 - CONTINUOUS RAIL

(215) BRIDGE RAIL HEIGHT: ............ 3.75 FT (1.14 M)

(53) MIN. VRT. CLEAR. OVER DECK: 99.99 FT (99.99 M)

(54) MIN. VRT. UNDERCLEARANCE: 14.75 FT (4.50 M)

CONDITION AND APPRAISAL DATA, PROPOSED IMPROVEMENTS, AND COST

(58) DECK:

(59) SUPERSTRUCTURE:

(60) SUBSTRUCTURE:

(61) CHANNEL:

(62) CULVERT: ........................... N

(222) APPROACHES:

(223) RETAINING WALL:

(36) TRAFFIC SAFETY FEAT: ... 1010

(75A) TYPE OF WORK: .............. 35 - GENERAL REHAB

(75B) WORK DONE BY: ............. 1 - CONTRACT

(76) IMPROVEMENT LENGTH: ..

(67) STRUCTURAL EVALUATION:

(68) DECK GEOMETRY:

(69) UNDERCLEARANCES:

(71) WATERWAY ADEQUACY:

(72) APPROACH ALIGNMENT:

(113) SCOUR CRITICAL:

(225) PURPOSE OF IMPROVEMENT:

(226) PRIORITY OF IMPROVEMENT:

(227) MAINTENANCE COST:

(228) REHAB./RECONSTR. COST: ...

(229) CONSTRUCTION COST:

4 - Stable; action required to pro

2 - REHAB/RECONSTRUCTION

C - MODERATE

ADDITIONAL INFORMATION

(230) STRUCTURE HISTORY:

1983, 2002-STRUCT. STEEL REPAINTED. 1998-DECK REPLACED WITH PRECAST PANELS(NB & SB). 2004-PRELIM. SCOUR ANALYSIS.

2006-SOME PIER BRGS. MODIFIED. 2010-APPROACHES PARTIALLY REPAVED.

(231) ADDITIONAL CONSIDERATIONS:

(330) ADDITIONAL CONFIG. INFO.:

http:77�09'28.00 http:38�57'48.60

APPENDIX STRUCTURE NO. 3300-002P

PHOTOGRAPHS STRUCTURE NO. 3300-002P

PHOTO #1 - LOOKING SOUTHBOUND TOWARD MT. VERNON

FLOW

PHOTO #2 - EAST (DOWNSTREAM) SIDE

PHOTO #3 - GENERAL TOPSIDE VIEW LOOKING SOUTH, NORTHBOUND

STRUCTURE

PHOTO #4 - TYPICAL CRACKING OF WEARING SURFACE; SPAN #1,

NORTHBOUND STRUCTURE SHOWN

PHOTO #5 - TYPICAL TRANSVERSE CRACKING

OF WEARING SURFACE AT DECK PANEL

JOINTS WITH EFFLORESCENCE; SPAN #2,

NORTHBOUND STRUCTURE SHOWN

PHOTO #6 - DELAMINATION AND SPALLING OF

WEARING SURFACE AT SOUTH EXPANSION

JOINT, NORTHBOUND STRUCTURE; NOTE

ASPHALT PATCHES HAVE FAILED; ALSO NOTE

SEAL LOOSE

PHOTO #7 - DELAMINATION AND SPALLING OF EAST CURB OVER

SOUTH PIER, NORTHBOUND STRUCTURE

PHOTO #8 - TYPICAL DETERIORATION OF APPROACH PAVEMENT IN

LEFT LANE, SOUTHBOUND STRUCTURE; SOUTH APPROACH SHOWN;

NOTE RIGHT LANE REPAVED

PHOTO #9 - TYPICAL DETERIORATION OF MORTAR WITH MASONRY

STONES LOOSE IN GUARDWALLS; EAST GUARDWALL, NORTH

APPROACH SHOWN

PHOTO #10 - GENERAL UNDERSIDE VIEW LOOKING SOUTH, SPAN #4

OF NORTHBOUND STRUCTURE

PHOTO #11 - TYPICAL INCOMPLETELY

POURED GROUT HAUNCH BETWEEN GIRDERS

AND DECK PANELS; EAST GIRDER AT SOUTH

ABUTMENT, SOUTHBOUND STRUCTURE

SHOWN

PHOTO #12 - DELAMINATION AND SPALLING

OF DECK UNDERSIDE ADJACENT TO WEST

GIRDER AT NORTH ABUTMENT, SOUTHBOUND

STRUCTURE; NOTE SURFACE RUST

REFORMING

PHOTO #13 - SPALL IN DECK UNDERSIDE IN CENTER BAY AT FLOOR

BEAM #7 IN SPAN #2, NORTHBOUND STRUCTURE; NOTE TYPICAL

RUSTING OF STEEL DECK PANEL JOINT PLATES

PHOTO #14 - TYPICAL CLOGGED DRAIN; WEST SIDE OF SPAN #4,

SOUTHBOUND STRUCTURE SHOWN

PHOTO #15 - TYPICAL RUSTING OF BEARINGS; EAST GIRDER BEARING

AT NORTH ABUTMENT, NORTHBOUND STRUCTURE SHOWN; NOTE

PACK RUST BENEATH ROCKER PREDATING PAINT

PHOTO #16 - TYPICAL MISSING ANCHOR BOLTS; WEST GIRDER

BEARING AT SOUTH PIER, NORTHBOUND STRUCTURE SHOWN

PHOTO #17 - VEGETATION GROWTH

EXTENDING ONTO EAST GIRDER BEARING

AND EAST GIRDER AT CENTER PIER,

SOUTHBOUND STRUCTURE

PHOTO #18 - TYPICAL SECTION LOSS ON

STRUCTURAL STEEL PREDATING PAINT; EAST

STRINGER AT SOUTH ABUTMENT,

SOUTHBOUND STRUCTURE SHOWN

PHOTO #19 - TYPICAL SURFACE RUST REFORMING ON GIRDER ENDS

AT ABUTMENTS; EAST GIRDER AT NORTH ABUTMENT, NORTHBOUND

STRUCTURE SHOWN

PHOTO #20 - TYPICAL SURFACE RUST REFORMING ON STRINGER

ENDS AT ABUTMENTS; EAST STRINGER AT NORTH ABUTMENT,

NORTHBOUND STRUCTURE SHOWN

PHOTO #21 - LATERAL BRACING GUSSET

RUSTED THROUGH AT FLOOR BEAM #13 TO

EAST GIRDER CONNECTION IN SPAN #3

PREDATING PAINT, SOUTHBOUND

STRUCTURE; NOTE GUSSET DOWN TO KNIFE

EDGE PREDATING PAINT

PHOTO #22 - LATERAL BRACING DOWN TO

KNIFE EDGE WITH AREAS RUSTED THROUGH

AT FLOOR BEAM #9 TO EAST GIRDER

CONNECTION IN SPAN #2 PREDATING PAINT,

NORTHBOUND STRUCTURE

PHOTO #23 - GENERAL VIEW OF SOUTH

ABUTMENT

PHOTO #24 - TYPICAL DELAMINATION AND

SPALLING OF ABUTMENT BREASTWALLS

WITH EXPOSED REBAR; EAST END OF SOUTH

ABUTMENT, NORTHBOUND STRUCTURE

SHOWN

PHOTO #25 - DELAMINATION AND SPALLING

OF SOUTH ABUTMENT BACKWALL WITH

EXPOSED REBAR, NORTHBOUND STRUCTURE

PHOTO #26 - PONDING ON TOP OF NORTH

ABUTMENT BREASTWALL, SOUTHBOUND

STRUCTURE; NOTE ACCUMULATION OF

DEBRIS

PHOTO #27 - TYPICAL VERTICAL CRACKING

OF WINGWALLS WITH EFFLORESCENCE;

NORTHEAST WINGWALL SHOWN; ALSO NOTE

SPALL WITH EMBEDDED TIMBER

PHOTO #28 - DETERIORATION OF NORTHEAST

WINGWALL AT BEARING SEAT WITH RUST

STAINING

PHOTO #29 - TYPICAL DETERIORATION OF

RETAINING WALLS; NORTH RETAINING WALL

AT NORTHBOUND STRUCTURE ABUTMENT

PHOTO #30 - GENERAL VIEW OF CENTER PIER

OF NORTHBOUND STRUCTURE, NORTH FACE;

NOTE VEGETATION GROWTH

PHOTO #31 - TYPICAL DELAMINATION AND

SPALLING OF PIER CAPS WITH EXPOSED

REBAR AT ENDS; NORTH FACE OF NORTH

PIER CAP AT WEST END, NORTHBOUND

STRUCTURE SHOWN

PHOTO #32 - LOOKING DOWNSTREAM

THROUGH STRUCTURE, SPAN #3

PHOTO #33 - LOOKING UPSTREAM THROUGH

STRUCTURE, SPAN #3

PHOTO #34 - EROSION OF NORTH CHANNEL

BANK AT NORTH PIER OF NORTHBOUND

STRUCTURE; NOTE DETERIORATION OF SILT

FENCE

File details come from the government source that posted it. Updated .