BRIDGE INSPECTION REPORT

DEAD RUN BRIDGE

GWMP OVER DEAD RUN

GEORGE WASHINGTON MEMORIAL PARKWAY

LN

STRUCTURE NO. 3300-001P

INSPECTION TYPE: ROUTINE

INSPECTION DATE: 4/13/11

Federal Highway Administration

Report prepared by: ED

MILE POINT:

KILOMETER POINT:

0.43 0.69

Federal Lands Bridge Office Bridge Inspection and Management Program 21400 Ridgetop Circle Sterling, Virginia 20166 http://www.efl.fhwa.dot.gov/FLHBO/BIP

STRUCTURE SUMMARY STRUCTURE NO. 3300-001P

DEAD RUN BRIDGE INSPECTION DATE: 4/13/11

BRIDGE IDENTIFICATION AND DESCRIPTION

MAIN SPAN MATERIAL: ....... STEEL CONTINUOUS NO. OF MAIN SPANS:

MAIN SPAN TYPE: ............... GIRDER & FLOOR BEAM SYSTEM NO. OF APPR. SPANS:

# OF BEAMS, MAIN SPAN: .. 4 STRUCT. TOTAL LENGTH: .. 307.8 FT (93.8 M)

DECK TYPE: ......................... CONCRETE CAST-IN-PLACE MAX. SPAN LENGTH: .......... 113.0 FT (34.4 M)

WEARING SURFACE: .......... MODIFIED CONCRETE DECK WIDTH: ...................... 73.0 FT (22.3 M)

ABUT. FOUNDATIONS: ........ SPREAD FTG ON BEARING MAT'L CURB TO CURB WIDTH: ..... 60.3 FT (18.4 M)

PIER FOUNDATION(S): ........ SPREAD FTG ON BEARING MAT'L YEAR BUILT:

ABUTMENT / PIER MAT'L: ... CONCRETE YEAR RECONSTRUCTED: .. 1998

PROJ./PLAN REF. NO: ......... 1A18,41,39,2 / 41901 SKEW ANGLE: ..................... 0 °

NPS ROAD CLASS: .............. 7 - URBAN PARKWAY FRACTURE CRITICAL: ........ YES

STRUCTURE HISTORY: ...... 1975-northbound bridge deck replaced with membrane added. 1983, 2001-structural steel repainted. 1998-southbound deck replaced with precast panels. 2010-approaches repaved.

LOCATION

GEORGE WASHINGTON MEMORIAL PARKWAY MILE POINT: ..................... 0.43 (KM PT 0.69)

STATE: ................................. VIRGINIA LOCATION: 0.5 MILES SOUTH OF I-495.

FACILITY CARRIED: ............ GWMP

FEATURE INTERSECTED: .. DEAD RUN

STRUCTURE EVALUATION SUMMARY

This fracture-critical steel girder bridge, which consists of both northbound and southbound structures, is in fair condition overall. The main problems are minor to moderate deterioration of the substructure concrete and the retaining walls which has progressed since the last inspection and widespread minor cracking and isolated delamination and spalling of the concrete wearing surface. The substructure and retaining walls should be repaired in order to prevent further concrete deterioration, and the wearing surface should be repaired and sealed to halt water intrusion.

Another issue at this time is the reformation of surface rust on the girder and stringer ends at the abutments, which is exacerbated by the leaking expansion joints. These joints should be resealed as necessary, and the girder and stringer ends should be repainted.

Other problems include clogged deck drains and isolated loose stones in the masonry guardwalls. Also, minor section loss on the structural steel superstructure occurred prior to repainting with a few locations rusted through;

however, the section loss does not affect the structural integrity. Repairs should be made as outlined in this report to prevent the possible development of more serious or costly problems in the future.

It should be noted that the approaches have been repaved and the lane markings have been repainted since the last inspection.

INSPECTION TEAM: M.D. HARLAN, R.E. ESTES (CLARK NEXSEN)

CONDITION ASSESSMENT:

MATTHEW D. HARLAN, P.E., FIELD TEAM LEADER

REPORT REVIEW:

GARY J. GOODLIN, FIELD TEAM LEADER 703-404-6253

REPORT APPROVAL: DATE: 8/17/11

MARCUS MILLER, P.E., LEAD STRUCTURAL ENGINEER 703-404-6252

RECOMMENDATIONS AND ESTIMATED COSTS STRUCTURE NO. 3300-001P

A (Critical) - Structure is closed, in imminent danger of collapse, or presents a critical safety hazard.

B (Major) - Structure is seriously deficient or presents a safety hazard, but can remain in service at reduced loads or with frequent inspections.

C (Moderate) - Structure is deficient, functionally obsolete, or requires substantial repairs to prevent a serious deficiency or unsafe condition.

D (Minor) - Structure is generally in good condition. Preventative maintenance may be required.

E (Special) - Structure is under construction or reconstruction.

D226 PRIORITY OF IMPROVEMENT

ITEM

NO.

MAINTENANCE RECOMMENDATIONS

(GENERALLY NOT FLHP ELIGIBLE)

QTY. UNIT COST

UNIT

ESTIMATE

COST

PRELIM.

58.3 REPAIR CONCRETE WEARING SURFACE AT EXPANSION JOINTS OF

NORTHBOUND STRUCTURE.

112 SF $

59.2,4,7 CLEAN AND PAINT GIRDER AND STRINGER ENDS AT ABUTMENTS. 620 SF

58.2,7 CLEAN DEBRIS FROM DECK DRAINS AND EXPANSION JOINTS. RESEAL DECK

EXPANSION JOINTS AS NECESSARY.

1 LS

222.3 RESET LOOSE STONES IN MASONRY GUARDWALLS. 1 CY

223.1 REMOVE VEGETATION GROWTH FROM NORTH ABUTMENT RETAINING WALL. 1 LS

PRELIM. MAINTENANCE TOTAL :

ITEM

NO.

REHABILITATION/RECONSTRUCTION

(TYPICALLY NEEDED WITHIN 5 YEARS)

QTY. UNIT

UNIT

COST ESTIMATES

PRELIM. COST

REHAB. RECONSTR.

58.3 CLEAN AND SEAL MODIFIED CONCRETE WEARING SURFACE 17,248 SF

60.1,3,4,6,1 5, 223.1

REPAIR DETERIORATED AREAS OF ABUTMENTS, PIERS, AND

RETAINING WALLS. CLEAN EXPOSED REBAR AT SHALLOW SPALLS

AND COAT WITH APPROVED SEALANT.

100 SF

PRELIM. REHABILITATION/RECONSTRUCTION TOTAL :

COST ESTIMATE SUMMARY

PRELIM. MAINTENANCE TOTAL:

PRELIM. REHABILITATION TOTAL:

PRELIM. RECONSTRUCTION TOTAL: ..

TOTAL ITEMIZED COSTS:

PRELIMINARY ESTIMATE TOTAL* :

(*Includes typical contract costs for mobilization, traffic control, and design/construction engineering; but does not include detour bridges, work beyond the bridge limits, or work not listed above. Estimates are approximate and are for preliminary planning purposes only; they should not be used as a complete or final engineers estimate.)

REMARKS: Cost estimates assume that the recommended actions will be combined with similar work being performed on other structures.

FIELD INSPECTION REPORT STRUCTURE NO. 3300-001P

G = GOOD (CODES 7 - 9) F = FAIR (CODES 5 - 6) P = POOR (CODES 0 - 4)

CONDITION RATING CODE EQUIVALENTS FOR SUB-ELEMENTS

SERIOUS CONDITION - loss of section, deterioration, spalling, or scour have seriously affected primary structural components. Local failures are possible.

Fatigue cracks in steel or shear cracks in concrete may be present.

CRITICAL CONDITION - advanced deterioration of primary structural elements. Fatigue cracks in steel or shear cracks in concrete may be present or scour may have removed substructure support. Unless closely monitored it may be necessary to close the structure until corrective action can be taken.

“IMMINENT” FAILURE CONDITION - major deterioration or section loss present in critical structural components or obvious vertical or horizontal movement affecting structure stability. Structure is closed to traffic but corrective action may return structure to light service.

FAILED CONDITION - out of service; beyond corrective action.

CONDITION RATING CODES FOR ITEMS 58 - 62, 222, 223

NOT APPLICABLE

EXCELLENT CONDITION

VERY GOOD CONDITION - no problems noted.

GOOD CONDITION - some minor problems.

SATISFACTORY CONDITION - structural elements show some minor deterioration.

FAIR CONDITION - all primary structural elements are sound but may have minor section loss, cracking, spalling, or scour.

POOR CONDITION - advanced section loss, deterioration, spalling, or scour.

N

58. DECK

ITEM REFERENCE AND REMARKS

OTHER

ALIGNMENT

DEFLECTION AND/OR VIBRATION

FASCIA(E)

DIAPHRAGMS AND BRACING

TRUSSES

FLOOR BEAMS AND STRINGERS

ARCH(ES) OR SLAB(S)

GIRDERS OR BEAMS

BEARING DEVICES

59. SUPERSTRUCTURE

OTHER

DEFLECTION AND/OR VIBRATION

UTILITIES

DRAINS AND DRAINAGE

PARAPETS AND/OR RAILINGS

CURBS, SIDEWALKS, AND MEDIAN

RIDEABILITY

WEARING SURFACE

EXPANSION JOINTS

DECK SLAB

OTHER

SETTLEMENT OR DEFLECTION

EROSION AND/OR SCOUR

FOUNDATIONS

CAPS AND/OR BEARING SEATS

PILE BENTS

WALLS AND/OR COLUMNS

PIER(S)

OTHER

SLOPE PROTECTION

SETTLEMENT OR DEFLECTION

EROSION AND/OR SCOUR

EXPANSION JOINTS

WEEP HOLES

WINGWALLS

FOUNDATIONS

BACKWALLS AND/OR BULKHEADS

CAPS AND/OR BEARING SEATS

PILE BENTS

BREASTWALLS OR COLUMNS

ABUTMENTS

60. SUBSTRUCTURE

1.

10.

2.

3.

4.

5.

6.

7.

8.

9.

10.

9.

8.

7.

6.

5.

4.

3.

2.

1.

PAINT

11.

G F N G N F F N G

N G

F N F F N F G N G G N N

G N F N G G N

11.

10.

9.

8.

7.

6.

5.

4.

3.

2.

1.

12.

13.

14.

15.

16.

17.

18.

19.

58.1 WIDESPREAD MINOR RANDOM CRACKING OF DECK UNDERSIDE.

GROUT HAUNCHES BETWEEN DECK AND STRINGERS OR GIRDERS

INCOMPLETELY POURED IN SEVERAL LOCATIONS WITH

WIDESPREAD SHRINKAGE CRACKING. MINOR CRACKING OF

UNDERSIDE OF OVERHANGS WITH EFFLORESCENCE, SOME

EXTENDING INTO CURBS.

NORTHBOUND STRUCTURE: MINOR HONEYCOMBING OF DECK

UNDERSIDE AT ISOLATED LOCATIONS. MINOR DELAMINATION AND

SPALLING OF DECK UNDERSIDE ADJACENT TO WEST GIRDER AT

SOUTH ABUTMENT. MINOR EFFLORESCENCE ON DECK UNDERSIDE

ALONG CONSTRUCTION JOINT AT SOUTH ABUTMENT. ISOLATED

CONCRETE PATCHING ON DECK UNDERSIDE BETWEEN FLOOR

BEAMS #8 AND #9 IN CENTER SPAN. MODERATE SPALLING (10'L X

18"W X 3"D) OF DECK UNDERSIDE AND WEST OVERHANG AT NORTH

ABUTMENT DUE TO UP TO 3/4" OF PACK RUST OVER TOP FLANGE

OF WEST GIRDER PREDATING PAINT.

SOUTHBOUND STRUCTURE: MINOR LONGITUDINAL CRACKING OF

DECK UNDERSIDE WITH EFFLORESCENCE IN PREVIOUS REPAIRS

AT SOUTH ABUTMENT. MINOR SPALL ON UNDERSIDE OF WEST

OVERHANG AT NORTH ABUTMENT.

58.2 MINOR TO MODERATE ACCUMULATION OF DEBRIS IN EXPANSION

JOINTS, PRIMARILY IN SHOULDERS. ACTIVE LEAKAGE THROUGH

EXPANSION JOINTS AT TIME OF INSPECTION.

SOUTHBOUND STRUCTURE: SEAL LOOSE (3'L) AT SOUTH

EXPANSION JOINT DUE TO MINOR EDGE SPALLING.

58.3 LATEX MODIFIED CONCRETE WEARING SURFACE. LANE MARKINGS

RESTRIPED SINCE LAST INSPECTION

NORTHBOUND STRUCTURE: WIDESPREAD MINOR MAP CRACKING

OF WEARING SURFACE, ESPECIALLY NORTH END AND CENTER

SPAN. MINOR TO MODERATE CRACKING AND BREAKING UP OF

WEARING SURFACE AT BOTH ENDS; SOME AREAS OF SPALLING

PATCHED WITH ASPHALT; MINOR SETTLEMENT OF PATCHES.

SOUTHBOUND STRUCTURE: WIDESPREAD MINOR MAP CRACKING

OF SOUTH HALF OF WEARING SURFACE AND MINOR TRANSVERSE

CRACKING AT JOINTS BETWEEN DECK PANELS.

F G G G F N

N

F

G

F

ITEM REFERENCE AND REMARKS

STREAM BED COMPOSITION : 9.

AVERAGE CLEAR OPENING 8.

NORMAL VELOCITY 7.

ADEQUACY OF OPENING 6.

OTHER 5.

WATERWAY OBSTRUCTIONS 4.

CHANNEL PROTECTION3.

EROSION AND/OR SCOUR2.

ALIGNMENT1.

61. CHANNEL 6

F F F G N

LOW

SUFF

36 FT.

SILT, ROCK

222. APPROACHES 7

OTHER 9.

ALIGNMENT 8.

SIGNS7.

SETTLEMENT 6.

EROSION5.

SURFACING4.

APPROACH GUARDRAIL 3.

2. RELIEF JOINTS

APPROACH SLABS1. N

N G G G G G G N

223. RETAINING WALL 6

OTHER 6.

SETTLEMENT OR DEFLECTION5.

EROSION AND/OR SCOUR4.

FOUNDATION3.

WEEP HOLES2.

1. WALL F

G N G G N

36. TRAFFIC AND SAFETY FEATURES

APPROACH GUARDRAIL ENDSD.

APPROACH GUARDRAILSC.

TRANSITIONSB.

BRIDGE RAILINGSA. 1

TRAFFIC SAFETY RATING CODES

0 - Does not meet standards or a safety feature is required and none is provided.

1 - Meets currently acceptable standards.

N - Not applicable or a safety feature is not required.

58.5 WIDESPREAD MINOR CRACKING OF CURBS AND SIDEWALK.

NORTHBOUND STRUCTURE: DETERIORATION OF JOINT FILLER IN

CURB AND SIDEWALK FASCIAE. MINOR DELAMINATION AND

SPALLING OF CURB AND SIDEWALK ALONG FASCIA AT ISOLATED

LOCATIONS. MINOR EDGE SPALLING OF EAST CURB AT NORTH

APPROACH.

58.6 MINOR SCRAPES ON RAILS WITH MINOR RUSTING AND PEELING OF

PAINT; MINOR RUSTING AND PEELING OF PAINT ON RAIL POST

BASE PLATES.

SOUTHBOUND STRUCTURE: PREVIOUSLY NOTED VEGETATION

GROWTH OVER WEST RAILING NEAR SOUTH PIER HAS BEEN

CLEARED SINCE LAST INSPECTION.

58.7 NORTHBOUND STRUCTURE: DECK DRAINS COVERED TO PREVENT

DRAINAGE ONTO STRUCTURAL STEEL SUPERSTRUCTURE.

SOUTHBOUND STRUCTURE: BOTH DECK DRAINS CLOGGED IN

CENTER SPAN. LOOSE AND MISSING ANGLES ON DRAIN

EXTENSION SUPPORTS AT ISOLATED LOCATIONS.

59.1 MINOR RUSTING OF BEARINGS; UP TO 1/2" PACK RUST BENEATH

ROCKERS PREDATING PAINT.

SOUTHBOUND STRUCTURE: RUST SCALE BENEATH EXTERIOR

ANCHOR BOLT WASHERS OF EAST BEARING AT SOUTH PIER WITH

ANCHOR BOLT NUTS NOT FULLY SEATED.

59.2,4,6,7 MINOR SECTION LOSS (UP TO 1/8") ON STRUCTURAL STEEL

PREDATING PAINT; MINOR RUST REFORMING ON GIRDER AND

STRINGER ENDS AT ABUTMENTS. MINOR RUSTING ALONG EDGES

OF GIRDER BOTTOM FLANGES AT ISOLATED LOCATIONS. LATERAL

BRACING MEMBERS AND GUSSET PLATES DOWN TO KNIFE EDGE

PREDATING PAINT AT ISOLATED LOCATIONS.

SOUTHBOUND STRUCTURE: PEELING OF PAINT WITH RUST SCALE

ON WEST GIRDER FIELD SPLICE AT FLOOR BEAM #4 IN SOUTH

SPAN. GAP (UP TO 1/8"W X 9"L) BETWEEN BOTTOM FLANGE OF

WEST GIRDER AND SPLICE PLATE AT SPLICE NEAR SOUTH PIER IN

CENTER SPAN; BOLTS FULLY TIGHT. MINOR SECTION LOSS ON

BOTTOM FLANGE (1" SECTION REMAINING, 1-1/4" ORIGINAL

SECTION) OF WEST GIRDER BETWEEN FLOOR BEAMS #8 AND #9 IN

CENTER SPAN PREDATING PAINT. SURFACE RUST WITH RUST

SCALE ON TOP FLANGE OF WEST GIRDER AT NORTH ABUTMENT.

SOUTHBOUND STRUCTURE: LATERAL BRACING AND GUSSET

PLATE RUSTED THROUGH IN END 4' AT FLOOR BEAM #4 TO WEST

GIRDER CONNECTION IN SOUTH SPAN PREDATING PAINT. TWO

HOLES (1/2" DIAMETER) RUSTED THROUGH LATERAL BRACING

GUSSET PLATE AT FLOOR BEAM #12 TO EAST GIRDER

CONNECTION PREDATING PAINT.

60, 223 WIDESPREAD GRAFFITI ON LOWER PORTIONS OF SUBSTRUCTURE

AND RETAINING WALLS.

ADDITIONAL ITEM REFERENCE AND REMARKS

60.1,3 MINOR TO MODERATE DELAMINATION AND SPALLING OF ABUTMENT BREASTWALLS WITH UP TO 10% SECTION

LOSS ON EXPOSED REBAR. MINOR ACCUMULATION OF DEBRIS ON ABUTMENT BEARING SEATS.

NORTHBOUND STRUCTURE: MODERATE DELAMINATION AND SPALLING OF CONCRETE PATCH AT WEST GIRDER BEARING SEAT AT SOUTH ABUTMENT. MINOR PONDING ON TOP OF SOUTH ABUTMENT BREASTWALL.

60.4 MINOR VERTICAL CRACKING OF ABUTMENT BACKWALLS WITH CHEMICAL STAINS; CRACKS EXTEND ACROSS

TOP. MINOR EDGE SPALLING ON TOP OF BACKWALLS.

NORTHBOUND STRUCTURE: MINOR DELAMINATION OF PREVIOUS REPAIRS IN FACE OF NORTH ABUTMENT BACKWALL. MINOR TO MODERATE RANDOM CRACKING AND MINOR DELAMINATION OF PREVIOUS REPAIRS IN

FACE OF SOUTH ABUTMENT BACKWALL.

SOUTHBOUND STRUCTURE: MINOR TO MODERATE DELAMINATION AND SPALLING OF SOUTH ABUTMENT

BACKWALL; MINOR RANDOM CRACKING THROUGHOUT PREVIOUS REPAIRS.

60.6 MINOR CRACKING OF WINGWALLS WITH EFFLORESCENCE AND POPOUTS. EXPOSED REBAR ON NORTH AND

SOUTHEAST WINGWALLS DUE TO INADEQUATE CONCRETE COVER.

60.7 MINOR RUST STAINING FROM WEEP HOLES; MODERATE CORROSION OF SLEEVES WITH RUST SCALE.

60.13 MINOR VEGETATION GROWTH ON PIER STEMS.

60.15 MINOR TO MODERATE DELAMINATION AND SPALLING WITH EXPOSED REBAR AT TOP AND ENDS OF PIER CAPS.

NORTHBOUND STRUCTURE: MINOR VERTICAL CRACK ON BOTH SIDES OF SOUTH PIER.

SOUTHBOUND STRUCTURE: MINOR DELAMINATION ON NORTH FACE OF EAST GIRDER BEARING SEAT AT

NORTH PIER.

60.17, 61.1,2,3

STREAM HAS MIGRATED TOWARD SOUTH PIERS CAUSING MINOR TO MODERATE CHANNEL BANK EROSION;

PLACEMENT OF ADDITIONAL RIPRAP AT SOUTH PIER OF NORTHBOUND STRUCTURE IN THE PAST. SCARCE

CHANNEL PROTECTION AT SOUTH PIERS.

222.3 MINOR DETERIORATION OF MORTAR WITH SEVERAL STONES LOOSE IN GUARDWALLS; MINOR WEATHERING OF

MASONRY STONES. UNSEALED ENDS OF MEDIAN RAILS RUST SCALED WITHIN.

222.4,6 APPROACHES REPAVED SINCE LAST INSPECTION.

222.7 "DEAD RUN" SIGNS AT WEST SIDE OF NORTH APPROACH AND EAST SIDE OF SOUTH APPROACH.

223.1 MINOR CRACKING WITH CHEMICAL STAINS, DELAMINATION, AND SPALLING OF CONCRETE RETAINING WALLS WITH EXPOSED REBAR; DETERIORATION OCCURS PRIMARILY ALONG ABUTMENT BREASTWALLS; POPOUTS IN

SEVERAL LOCATIONS. HEAVY VEGETATION ON NORTH ABUTMENT RETAINING WALL.

36.B,C,D MASONRY APPROACH GUARDWALLS IN MEDIAN AND AT EITHER SIDE OF ROADWAY. MASONRY APPROACH GUARDWALLS NOT ATTACHED TO BRIDGE RAILINGS. END TREATMENTS DO NOT MEET CURRENT AASHTO

SPECIFICATIONS.

STRUCTURE LOAD RATING STRUCTURE NO. 3300-001P

TRUCK TYPE

INVENTORY RATING (NORMAL TRAFFIC) OPERATING RATING (MAXIMUM LOAD)

TONS METRIC TONS TONS METRIC TONS

H 23 21 38 35

HS 36 33 60 55

TYPE 3 35 32 58 53

TYPE 3S2 40 36 67 60

TYPE 3-3 44 40 73 67

DESIGN LOADING: HS20 (MS18)

X CAPACITY MEETS OR EXCEEDS DESIGN LOAD

CAPACITY IS LESS THAN DESIGN LOAD

ORIGINAL LOAD RATING CALCULATION APPLICABLE

ORIGINAL LOAD RATING CALCULATION REVISED

DATE OF LOAD RATING CALCULATION:

LOAD RATING CONTROLLED BY:

REMARKS: RATING IS BASED ON DESIGN LOAD OF STRUCTURE.

STRUCTURE INVENTORY AND APPRAISAL STRUCTURE NO. 3300-001P

STRUCTURE IDENTIFICATION

(201) PARK: GEORGE WASHINGTON MEMORIAL PARKWAY

(202) STRUCTURE NAME: .......... DEAD RUN BRIDGE

(203) STRUCTURE KIND: ............ 1 - BRIDGE

(204) STRUCTURE NUMBER: ..... 3300-001P

(205) NPS REGION: .................... 2 - NATIONAL CAPITAL

(206) ROUTE CODE NUMBER: ... 1

(207) ROAD SECTION NO: .......... 001P

(208) NPS ROAD CLASS: ............ 7 - URBAN PARKWAY

(209) WITHIN NPS BNDRY?: ....... YES

(210) OPERATING UNIT: ............. PARK

(211) PROJECT NO(S): ................ 1A18,41,39,2

(212) DRAWING NUMBERS:

(21) MAINTAINED BY: ................. 66 - NATIONAL PARK SERVICE

(22) OWNER: ............................... 66 - NATIONAL PARK SERVICE

(1) STATE:

(2) STATE HWY. AGENCY DIST:

(3) COUNTY CODE:

(4) CITY/PLACE CODE:

(5) INVENTORY ROUTE:

(6) FEATURES INTERSECTED:

(7) FACILITY CARRIED:

(8) STATE STRUCTURE NO:

(9) LOCATION:

(10) INV. RTE. - MIN. VERT. CLR: ..

(11) MILE POINT:

(27) YEAR BUILT:

(106) YEAR RECONSTRUCTED:

(20) TOLL:

(37) HISTORICAL DESIGNATION: ..

513 - VIRGINIA (VA)

059 - FAIRFAX

161000010

DEAD RUN

GWMP

3300001P0000000

0.5 MILES SOUTH OF I-495.

99.99 FT (99.99 M)

0.43 (KM PT 0.69)

3 - FREE ROAD

5 - NOT ELIGIBLE

STRUCTURE DESCRIPTION, FOUNDATION, AND DECK TYPE

(43A) MAIN STR. MATERIAL: ..

(43B) MAIN STR. TYPE:

(45) NO. OF MAIN SPANS:

(48) MAX. SPAN LENGTH:

(49) STRUCTURE LENGTH:

(216A) ABUTMENT #1 FDN:

(216B) ABUTMENT #2 FDN:

(217A) PREDOM. PIER FDN.: ..

(217B) SECOND. PIER FDN: ...

(107) DECK TYPE:

4 - STEEL CONTINUOUS

03 - GIRDER & FLOOR BEAM SYSTEM

113.0 FT (34.4 M)

307.8 FT (93.8 M)

2 - SPREAD FTG ON BEARING MAT'L

2 - SPREAD FTG ON BEARING MAT'L

2 - SPREAD FTG ON BEARING MAT'L

2 - SPREAD FTG ON BEARING MAT'L

1 - CONCRETE CAST-IN-PLACE

(44A) APPR. STR. MATERIAL: ........ 0 - OTHER

(44B) APPR. STR. TYPE: ................ 00 - OTHER

(46) NO. OF APPROACH SPANS: .. 0

(108) WEAR SURFACE/PROTECT SYSTEM:

A) TYPE WEARING SURFACE: .. 3 - MODIFIED CONCRETE

B) TYPE MEMBRANE: ................. 9 - OTHER

C) TYPE PROTECTION: .............. 0 - NONE

(218) IS SALT USED?: ..................... YES

LOAD RATING AND POSTING

(31) DESIGN LOAD: ................. 5 - HS20 (MS18) (41) LOAD RESTRICTION: ......... A - OPEN, NO RESTRICTION

(66) INVENTORY RATING: ...... 36.0 TONS (33.0 METRIC TONS) (70) BRIDGE POSTING: .............. 5 - NO POSTING REQUIRED

(64) OPERATING RATING: ...... 60.0 TONS (55.0 METRIC TONS)

INSPECTION DATES

(90) INSPECTION DATE: 4/11 (91) FREQ. OF INSP: 24 MONTHS (92 / 93) CRITICAL FEATURE INSPECTION (CFI):

(219) ADD. STUDIES NEEDED: N - 0 - NONE (A) FRACTURE CRITICAL: ... YES

INSP. EVERY: 24 MONTHS - LAST INSP. : 4/11 (220) SPECIAL STUDY TYPE: 5 - SCOUR

(B) UNDERWATER: .............. NO

(221) SPECIAL STUDY DATE: 8/04 INSP. EVERY: MONTHS - LAST INSP. :

(C) SPECIAL INSPECTION: .. NO

INSP. EVERY: MONTHS - LAST INSP. :

o

STRUCTURE INVENTORY AND APPRAISAL STRUCTURE NO. 3300-001P

GEOMETRY, TRAFFIC, AND NAVIGATIONAL DATA

(16) LATITUDE: ............................. 38°58'50.40"

(17) LONGITUDE: ......................... 77°10'26.70"

(19) DETOUR LENGTH: ............... 1 MI (2 KM)

(28A) LANES ON STRUCT:

(28B) LANES UNDER STRUCT: ... 00

(42A) SERVICE ON: ..................... 5 - HIGHWAY-PEDESTRIAN

(42B) SERVICE UNDER: .............. 5 - WATERWAY

(29) AVG. DAILY TRAFFIC:

(30) YEAR OF ADT:

(114) FUTURE ADT:

(115) YEAR OF FUTURE ADT:

(101) PARALLEL STRUCTURE: ... N - NONE

(38) NAVIGATION CONTROL?: ... 0

(39) VERTICAL CLEARANCE: ...... 0.0 FT (0.0 M)

(40) HORIZ. CLEARANCE: ........... 0.0 FT (0.0 M)

(111) ABUT. OR PIER PROT:

LATERAL UNDERCLEARANCE:

(55) RIGHT: ....................... 0.0 FT (0.0 M)

(56) LEFT: ......................... 0.0 FT (0.0 M)

(51) CURB TO CURB WIDTH: ........... 60.3 FT (18.4 M)

(52) DECK WIDTH: ............................ 73.0 FT (22.3 M)

(32) APPR. ROADWAY WIDTH: ........ 48.0 FT (14.6 M)

(213) APPR. PAVEMENT WIDTH: ..... 48.0 FT (14.6 M)

LEFT SHOULDER: .................. 0.0 FT (0.0 M)

RIGHT SHOULDER: ................ 0.0 FT (0.0 M)

(33) BRIDGE MEDIAN: ....................... 1 - OPEN MEDIAN

(34) SKEW ANGLE: ............................ 0 °

(35) DECK FLARE?: ........................... NO

(47) TOTAL HORIZ. CLEARANCE: .... 32.2 FT (9.8 M)

(50) SIDEWALKS:

LEFT : ...................................... 0.0 FT (0.0 M)

RIGHT : ................................... 3.5 FT (1.1 M)

(214) BRIDGE RAIL TYPE:

RAIL CONFIGURATION: ......... 1 - FULL HEIGHT (NO PARAPE

MATERIAL: .............................. 4 - STEEL

DESIGN TYPE: ........................ 1 - CONTINUOUS RAIL

(215) BRIDGE RAIL HEIGHT: ............ 2.92 FT (0.89 M)

(53) MIN. VRT. CLEAR. OVER DECK: 99.99 FT (99.99 M)

(54) MIN. VRT. UNDERCLEARANCE: 0.00 FT (0.00 M)

CONDITION AND APPRAISAL DATA, PROPOSED IMPROVEMENTS, AND COST

(58) DECK:

(59) SUPERSTRUCTURE:

(60) SUBSTRUCTURE:

(61) CHANNEL:

(62) CULVERT: ........................... N

(222) APPROACHES:

(223) RETAINING WALL:

(36) TRAFFIC SAFETY FEAT: ... 1010

(75A) TYPE OF WORK: .............. 35 - GENERAL REHAB

(75B) WORK DONE BY: ............. 1 - CONTRACT

(76) IMPROVEMENT LENGTH: .. 308.0 FT (93.9 M)

(67) STRUCTURAL EVALUATION:

(68) DECK GEOMETRY:

(69) UNDERCLEARANCES:

(71) WATERWAY ADEQUACY:

(72) APPROACH ALIGNMENT:

(113) SCOUR CRITICAL:

(225) PURPOSE OF IMPROVEMENT:

(226) PRIORITY OF IMPROVEMENT:

(227) MAINTENANCE COST:

(228) REHAB./RECONSTR. COST: ...

(229) CONSTRUCTION COST:

N

8 - Stable; scour above top of fo

3 - CONSTRUCTION

D - MINOR

ADDITIONAL INFORMATION

(230) STRUCTURE HISTORY:

1975-northbound bridge deck replaced with membrane added. 1983, 2001-structural steel repainted. 1998-southbound deck replaced with precast panels. 2010-approaches repaved.

(231) ADDITIONAL CONSIDERATIONS:

(330) ADDITIONAL CONFIG. INFO.:

1999, 2001, 2006 - SNOOPER INSPECTION. 2003-U/T ON CAT. D DETAILS.

http:77�10'26.70 http:38�58'50.40

APPENDIX STRUCTURE NO. 3300-001P

PHOTOGRAPHS STRUCTURE NO. 3300-001P

PHOTO #1 - LOOKING SOUTHBOUND TOWARD MT. VERNON

FLOW

PHOTO #2 - WEST (UPSTREAM) SIDE

PHOTO #3 - GENERAL TOPSIDE VIEW

LOOKING NORTH, SOUTHBOUND STRUCTURE

PHOTO #4 - LOOSE SEAL AT SOUTH

EXPANSION JOINT, SOUTHBOUND

STRUCTURE; NOTE EDGE SPALLING ON TOP

OF ABUTMENT BACKWALL

PHOTO #5 - TYPICAL TRANSVERSE CRACKING

OF WEARING SURFACE, SOUTHBOUND

STRUCTURE; SOUTH SPAN SHOWN

PHOTO #6 - CRACKING AND BREAKING UP OF

WEARING SURFACE AT SOUTH END,

NORTHBOUND STRUCTURE; NOTE ASPHALT

PATCHING AND SETTLEMENT OF PATCHING

PHOTO #7 - TYPICAL DETERIORATION OF

APPROACH GUARDWALLS; SOUTHWEST

GUARDWALL, SOUTHBOUND STRUCTURE

SHOWN; NOTE MASONRY STONES LOOSE

PHOTO #8 - TYPICAL WEATHERING OF

MASONRY STONES IN GUARDWALLS;

SOUTHEAST GUARDWALL, NORTHBOUND

STRUCTURE SHOWN

PHOTO #9 - GENERAL UNDERSIDE VIEW LOOKING SOUTH, CENTER

SPAN, NORTHBOUND STRUCTURE

PHOTO #10 - TYPICAL INCOMPLETELY POURED GROUT HAUNCH

BETWEEN GIRDER AND DECK; WEST GIRDER AT NORTH ABUTMENT,

NORTHBOUND STRUCTURE SHOWN

PHOTO #11 - CONCRETE PATCHING ON DECK

UNDERSIDE BETWEEN FLOOR BEAMS #8 AND

#9 IN CENTER SPAN, NORTHBOUND

STRUCTURE; ALSO NOTE TYPICAL

HONEYCOMBING

PHOTO #12 - SPALLING OF DECK UNDERSIDE

AT NORTH ABUTMENT, NORTHBOUND

STRUCTURE ALONG WEST GIRDER

PHOTO #13 - TYPICAL CLOGGED DRAIN; WEST SIDE OF CENTER SPAN,

SOUTHBOUND STRUCTURE SHOWN; ALSO NOTE TYPICAL SECTION

LOSS ON GIRDERS PREDATING PAINT

PHOTO #14 - TYPICAL RUSTING OF BEARINGS; EAST BEARING AT

SOUTH ABUTMENT, NORTHBOUND STRUCTURE SHOWN; NOTE

TYPICAL PACK RUST BENEATH ROCKER PREDATING PAINT

PHOTO #15 - SURFACE RUST WITH RUST SCALE ON TOP FLANGE OF

WEST GIRDER AT NORTH ABUTMENT, SOUTHBOUND STRUCTURE

PHOTO #16 - TYPICAL RUST REFORMING ON STRINGER ENDS AT

ABUTMENTS; WEST STRINGER AT SOUTH ABUTMENT, NORTHBOUND

STRUCTURE SHOWN

PHOTO #17 - LATERAL BRACING AND GUSSET PLATE RUSTED

THROUGH AT FLOOR BEAM #4 TO WEST GIRDER CONNECTION IN

SOUTH SPAN PREDATING PAINT, SOUTHBOUND STRUCTURE

PHOTO #18 - GENERAL VIEW OF SOUTH ABUTMENT

PHOTO #19 - TYPICAL DELAMINATION AND

SPALLING OF ABUTMENT BREASTWALLS

WITH SECTION LOSS TO EXPOSED REBAR;

WEST END OF NORTH ABUTMENT,

NORTHBOUND STRUCTURE SHOWN

PHOTO #20 - PONDING ON TOP OF SOUTH

ABUTMENT BREASTWALL, NORTHBOUND

STRUCTURE

PHOTO #21 - CRACKING AND DELAMINATION OF PREVIOUS REPAIRS

IN SOUTH ABUTMENT BACKWALL, NORTHBOUND STRUCTURE; ALSO

NOTE EVIDENCE OF JOINT LEAKAGE

PHOTO #22 - EXPOSED REBAR ON SOUTHEAST WINGWALL

PHOTO #23 - GENERAL VIEW OF SOUTH PIER

OF NORTHBOUND STRUCTURE, SOUTH FACE;

NOTE VEGETATION GROWTH

PHOTO #24 - TYPICAL DETERIORATION OF

RETAINING WALLS ALONG ABUTMENT

BREASTWALLS; NORTH RETAINING WALL

SHOWN; NOTE VEGETATION GROWTH

PHOTO #25 - LOOKING UPSTREAM THROUGH

STRUCTURE, CENTER SPAN

PHOTO #26 - LOOKING DOWNSTREAM

THROUGH STRUCTURE, CENTER SPAN

PHOTO #27 - EROSION OF SOUTH CHANNEL BANK

File details come from the government source that posted it. Updated .